Electricity Department Tender

View complete overview of Goa Electricity Department Tender

Electricity Department Tender

Works
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date24 Jan 2024
Closing Date29 Feb 2024
Tender Amount₹ 11,92,108 
Notes
Download

Costs

  • EMD

    ₹ 23,842
  • Document Cost

    ₹ 1,500
  • Tender Fee

    ₹ 2,384

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of Cross Arm Channel 2Pin .The cross arms shall be made of M.S. channel of ISMC-75 vide table 2 of IS: 8081 1964 . The cross arms shall be without any joints. The cross arms shall be hot dipped galvanized generally conforming to IS - 2633/72. The length of the 4pin cross arm shall be 1110mm with 4 holes of 22 dia each on each flange section. In addition 2 holes of size 18mm x 40mm slotted holes shall be provided on the cross arm for clamping arrangement to the pole. The length of the 4pin side cross arm shall be 1410mm with 4 holes of 22 dia each on each flange section. In addition 2 holes of size 18mm x 40mm slotted holes shall be provided on the cross arm 40 mm from the left edge of the X-arm for clamping arrangement to the pole & two holes of size 17mm dia at 355mm & 660mm from the slotted hole for arrangement to fix angle support. The angle support shall be of ISA 50x50x6mm G.I. with 17 mm dia holes at the two ends. The other end of the angle shall be clamps utilizing suitable G. I. stay clamps of length 312mm end to end

23

13087

569

... More
Supply of GI Xarm clamp LA for 7.5mts pole.shall be hot dipped galvanized generally conforming to IS - 2633/73

58

10672

184

... More
Supply of GI stay clamp SA for 7.5mts pole.shall be hot dipped galvanized generally conforming to IS - 2633/73

3

552

184

... More
Supply of GI Xarm clamp LA for 9mts pole.shall be hot dipped galvanized generally conforming to IS - 2633/74

15

3990

266

... More
Supply of GI Xarm clamp SA for 9mts pole.shall be hot dipped galvanized generally conforming to IS - 2633/75

5

1330

266

... More
Supply of cut point cross arm 1.3 mtr long.Cross arms shall be made of HDGI channel of size ISMC 75X40. hot dip galvanizing generally conforming to IS – 2633/72 . The cross arm shall not be welded/joined at any place except as specified

1

1959

1959

... More
Supply of Guard cross arm 1.5 mtr long.Cross arms shall be made of HDGI channel of size ISMC 75X40. hot dip galvanizing generally conforming to IS – 2633/72 . The cross arm shall not be welded/joined at any place except as specified

1

2196

2196

... More
Supply of top fitting channel 0.7 mtr long.Cross arms shall be made of HDGI channel of size ISMC 75X40. hot dip galvanizing generally conforming to IS – 2633/72 . The cross arm shall not be welded/joined at any place except as specified

1

819

819

... More
Supply of 11 KV Disc Insulators 70KN with H.D.G.I. Metal parts.11 KV disc insulators ball and socket type, type ‘A’ porcelain brown glazed duly cemented at factory with MCI socket cap, forged steel ball pin and supplied with Phosphor bronze “W” split pin as per IS 731-1971 as amended upto date. Pin ball diameter 16 mm. Minimum Creepage distance 320 mm. Ferrous parts shall be galvanized as per relevant IS

3

8658

2886

... More
Supply of Insulator -(LT)pin with HDGI Pin.Pin L.T. brown glazed Porcelain pin insulators of size 100mm x 70mm conforming to type 1 fig 1 of IS:1445/77 as amended upto date. Minimum failing load shall be 16kN. Insulators shall have marking and packing as prescribed in IS

107

28141

263

... More
Supply of Insulator -(LT) Shackle .L.T. brown glazed shackle insulators of size 100mm x 115mm conforming to fig.No.4 and type 2 of IS: 1445/77 as amended upto date. Minimum failing load shall be 16kN. Insulators shall have marking and packing as prescribed in IS

96

35712

372

... More
Supply of ACSR 'WEASEL' of size ( 6/1/2.59mm) for earthing and jumpering .Packing and marking of drum will be as per IS:Conductor length shall be 1500 mtr. with tolerance of +/- 5%

0.28

9354

33409

... More
Supply of conductor-AA ANT, 2. 7/3.10 mm ..7/3.10mm,Hard drawn stranded AACC to IS:398(Pt-I/96) as amended upto date

2.31

111078

48086

... More
Supply of conductor -AA GNAT,1. 7/2.21 mm,1.7/2.21mm,Hard drawn stranded AACC to IS:398(Pt-I/96) as amended upto date

2.93

73982

25293

... More
Supply & fixing of Anticlimbing device(barbed wire).Hot dip galvanized steel barbed wire type 4 conforming to IS:278/1962 as amended upto date and galvanization conforming to IS:4826/1979as amended upto date

2

290

145

... More
Supply of Enamelled danger board of size 250mm x 200mm

2

496

248

... More
Supply of Earthing complete with 2.5mts long, 40mm GI earthing pipe, class B, 20kgs each of salt and charcoal, excvation, re-filling etc.Earthing pipe made of Hot Dip galvanized steel tube of heavy class, 40mm nominal bore conforming to IS 1239 Part 1 1990 as amended upto date and Hot Dip zinc coating shall conform to IS 4736-1968 as amended upto date

5

22140

4428

... More
Supply of Stay set complete for 9.0 mts RCC Pole.HDGI Stay Sets Complete Comprising of stay rod with plate, HDGI stay wire of size 7/10swg, Break insulator of 15KV/8KV,HDGI turn buckle with eye bolt, suitable HDGI stay clamps, HDGI nut bolts, . The Stay wire shall comply with the specific requirements of IS: 2141-1979, IS: 4826-1979 & IS: 6594-1974 or the latest versions thereof and also as per the specifications enclosed.

2

8734

4367

... More
Supply of Stay set complete for 7.5 mts RCC Pole.HDGI Stay Sets Complete Comprising of stay rod with plate, HDGI stay wire of size 7/10swg, Break insulator of 15KV/8KV,HDGI turn buckle with eye bolt, suitable HDGI stay clamps, HDGI nut bolts, . The Stay wire shall comply with the specific requirements of IS: 2141-1979, IS: 4826-1979 & IS: 6594-1974 or the latest versions thereof and also as per the specifications enclosed.

21

85428

4068

... More
Supply of HDGI Structure Materials

274

46306

169

... More
Supply of HDGI stay clamps for RCC,Pole 9 mtr L.A.shall be hot dipped galvanized generally conforming to IS-2633/72

10

4910

491

... More
Supply of 11 KV GOAB switch with 200 A.12 KV rated voltage GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming to IS: 9921-Part1 to V as amended upto date and detailed specifications enclosed herewith. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufactures of the insulators and have minimum 320mm creepage distance and AB switches contacts shall be of copper/copper alloy

1

23535

23535

... More
Supply of 11 KV HG fuse,200A, Horn gap type fuse I.TECHNICAL PARTICULARS: 1. Highest System voltage : 12 KV (R.M.S) 2. Impulse voltage withstand voltage : 75 KV (Peak) 3. One minute power frequency withstand voltage : 35 KV (R.M.S.) 4. Continuous current rating of the unit : 200 Amps

1

10450

10450

... More
Supply of 9 KV, 5A Lightning Arrestor, pole mounted.9 KV, 5 KA nominal discharge current Metal Oxide gapless distribution class lightning arrestor conforming to IEC-60099-4 and IS 3070 Part 3 1993 as amended upto date suitable for 11 KV 50 HZ effectively earthed neutral system with necessary mounting arrangements and connector suitable to connect ACSR conductor upto overall diameter 12.30 mm.The marking of the Lightning Arrestors shall be as per IS

3

9099

3033

... More
Supply of MS Distribution box complete.M. S. distribution box MCCB of 400 Amps capacity Kit Kat Porcelain fuse carrier and base with extended terminals.

1

63140

63140

... More
Supply of XLPE armoured XLPE 3 1/2 core 95 sq.mm. The armoured cable of sizes as required i.e. 90Sq.mm that shall be suitably terminated at both the ends with appropriate sizes of Aluminum lugs duly crimped using a crimping tool. Appropriate sizes of GJ/ Brass nut / bolts/washers shall be used for firmly connecting the same to the MCCB's/Transformer L.T. Bushings/Outgoing LT feeder

144

105696

734

... More
Supply of XLPE armoured cable 1 core 120 sq.mm.The unarmoured cable shall be of 1 core and of sizes as required i.e. 120Sq.mm that shall be suitably terminated at both the ends with appropriate sizes of Aluminum lugs duly crimped using a crimping tool. Appropriate sizes of G.I / Brass nut / bolts / washers shall be used for firmly connecting the same to the MCCB’s/Transformer L.T. Bushings/Outgoing LT feeder

48

7872

164

... More
Supply of HDGI nuts & bolts.G.I. Hexagonal head bolts and hexagonal nuts conforming to IS 1363 part 1 to 3 1992 as amended upto date.The bolts and nuts shall be hot dip galvanized as per IS: 2629-1985 as amended upto date

45

10260

228

... More
Supply of Aluminum crimping lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade 1E of IS 5082-1969 suitable for aluminium cables of following sizes: 1. 120 Sq.mm.

8

432

54

... More
Supply of Aluminum crimping lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade 1E of IS 5082-1969 suitable for aluminium cables of following sizes: 1. 95 Sq.mm.

12

480

40

... More
Miscellaneous materials Such as Crimping lugs,screws etc

1

500

500

... More
Erection Cost

-

-

-

... More
Erection of 9 mts. long RCC poles .The poles should be as per drawing approved by CEE and conforming to IS standards as amended upto date. The Component used for pole shall conform to following IS amended upto date.

2

8816

4408

... More
Erection of 7.5mts. long RCC poles .The poles should be as per drawing approved by CEE and conforming to IS standards as amended upto date. The Component used for pole shall conform to following IS amended upto date.

19

70091

3689

... More
Fixing of Cross Arm Channel 4Pin .The cross arms shall be made of M.S. channel of ISMC-75 vide table 2 of IS: 8081 1964 . The cross arms shall be without any joints. The cross arms shall be hot dipped galvanized generally conforming to IS - 2633/72. The length of the 4pin cross arm shall be 1110mm with 4 holes of 22 dia each on each flange section. In addition 2 holes of size 18mm x 40mm slotted holes shall be provided on the cross arm for clamping arrangement to the pole. The length of the 4pin side cross arm shall be 1410mm with 4 holes of 22 dia each on each flange section. In addition 2 holes of size 18mm x 40mm slotted holes shall be provided on the cross arm 40 mm from the left edge of the X-arm for clamping arrangement to the pole & two holes of size 17mm dia at 355mm & 660mm from the slotted hole for arrangement to fix angle support. The angle support shall be of ISA 50x50x6mm G.I. with 17 mm dia holes at the two ends. The other end of the angle shall be clamps utilizing suitable G. I. stay clamps of length 312mm end to end

44

11484

261

... More
Fixing of Cross Arm Channel 2Pin .The cross arms shall be made of M.S. channel of ISMC-75 vide table 2 of IS: 8081 1964 . The cross arms shall be without any joints. The cross arms shall be hot dipped galvanized generally conforming to IS - 2633/72. The length of the 4pin cross arm shall be 1110mm with 4 holes of 22 dia each on each flange section. In addition 2 holes of size 18mm x 40mm slotted holes shall be provided on the cross arm for clamping arrangement to the pole. The length of the 4pin side cross arm shall be 1410mm with 4 holes of 22 dia each on each flange section. In addition 2 holes of size 18mm x 40mm slotted holes shall be provided on the cross arm 40 mm from the left edge of the X-arm for clamping arrangement to the pole & two holes of size 17mm dia at 355mm & 660mm from the slotted hole for arrangement to fix angle support. The angle support shall be of ISA 50x50x6mm G.I. with 17 mm dia holes at the two ends. The other end of the angle shall be clamps utilizing suitable G. I. stay clamps of length 312mm end to end

23

5336

232

... More
Fixing of GI Xarm clamp LA for 7.5mts pole.shall be hot dipped galvanized generally conforming to IS - 2633/73

58

1856

32

... More
Fixing of GI stay clamp SA for 7.5mts pole.shall be hot dipped galvanized generally conforming to IS - 2633/73

3

96

32

... More
Fixing of GI Xarm clamp LA for 9mts pole.shall be hot dipped galvanized generally conforming to IS - 2633/74

15

675

45

... More
Fixing of GI Xarm clamp SA for 9mts pole.shall be hot dipped galvanized generally conforming to IS - 2633/75

5

225

45

... More
Fixing of HDGI cut point cross arm ISMC channel, 75 x 40mm, 1.3 mts long of minimum tensile strength 410 MPA conforming to IS 2062 as amended upto date

1

492

492

... More
Fixing of HDGI Guard cross arm ISMC channel, 75 x 40mm, 1.5 mts long of minimum tensile strength 410 MPA conforming to IS 2062 as amended upto date

1

546

546

... More
Fixing of HDGI Top fitting cross arm ISMC channel, 75x40mm, 0.7mts long

1

228

228

... More
Fixing of 11 KV Disc Insulators 70KN with H.D.G.I. Metal parts.11 KV disc insulators ball and socket type, type ‘A’ porcelain brown glazed duly cemented at factory with MCI socket cap, forged steel ball pin and supplied with Phosphor bronze “W” split pin as per IS 731-1971 as amended upto date. Pin ball diameter 16 mm. Minimum Creepage distance 320 mm. Ferrous parts shall be galvanized as per relevant IS

3

1125

375

... More
Fixing of Insulator -(LT) pin with HDGI Pin.Pin L.T. brown glazed Porcelain pin insulators of size 100mm x 70mm conforming to type 1 fig 1 of IS:1445/77 as amended upto date. Minimum failing load shall be 16kN. Insulators shall have marking and packing as prescribed in IS

107

18511

173

... More
Fixing of Insulator -(LT) Shackle .L.T. brown glazed shackle insulators of size 100mm x 115mm conforming to fig.No.4 and type 2 of IS: 1445/77 as amended upto date. Minimum failing load shall be 16kN. Insulators shall have marking and packing as prescribed in IS

96

19968

208

... More
Stringing of ACSR 'WEASEL' of size ( 6/1/2.59mm) for earthing and jumpering .Packing and marking of drum will be as per IS:Conductor length shall be 1500 mtr. with tolerance of +/- 5%

0.28

1990

7110

... More
Stringing of of Conductor-AA ANT ,2.7/3.10mm,Hard drawn stranded AACC to IS:398(Pt-I/96) as amended upto datePacking and marking of drum will be as per IS:Conductor length shall be 1500 mtr. with tolerance of +/- 5%

2.31

15324

6634

... More
Stringing of of Conductor-AA GNAT ,1.7/2.21mm,Hard drawn stranded AACC to IS:398(Pt-I/96) as amended upto date

2.93

18085

6183

... More
Fixing of Anticlimbing device(barbed wire).Hot dip galvanized steel barbed wire type 4 conforming to IS:278/1962 as amended upto date and galvanization conforming to IS:4826/1979as amended upto date

2

92

46

... More
Fixing of Enamelled danger board of size 250mm x 200mm

2

114

57

... More
Providing of Earthing complete with 2.5mts long, 40mm GI earthing pipe, class B, 20kgs each of salt and charcoal, excvation, re-filling etc.Earthing pipe made of Hot Dip galvanized steel tube of heavy class, 40mm nominal bore conforming to IS 1239 Part 1 1990 as amended upto date and Hot Dip zinc coating shall conform to IS 4736-1968 as amended upto date

5

13325

2665

... More
Providing of Stay set complete for 9.0 mts RCC Pole.HDGI Stay Sets Complete Comprising of stay rod with plate, HDGI stay wire of size 7/10swg, Break insulator of 15KV/8KV,HDGI turn buckle with eye bolt, suitable HDGI stay clamps, HDGI nut bolts, . The Stay wire shall comply with the specific requirements of IS: 2141-1979, IS: 4826-1979 & IS: 6594-1974 or the latest versions thereof and also as per the specifications enclosed.

2

4932

2466

... More
Proviidng of Stay set complete for 7.5 mts RCC Pole.HDGI Stay Sets Complete Comprising of stay rod with plate, HDGI stay wire of size 7/10swg, Break insulator of 15KV/8KV,HDGI turn buckle with eye bolt, suitable HDGI stay clamps, HDGI nut bolts, . The Stay wire shall comply with the specific requirements of IS: 2141-1979, IS: 4826-1979 & IS: 6594-1974 or the latest versions thereof and also as per the specifications enclosed.

21

50484

2404

... More
Fixing of HDGI Structure Materials

274

12878

47

... More
Fixing of HDGI stay clamps for RCC,Pole 9 mtr L.A.shall be hot dipped galvanized generally conforming to IS-2633/72

10

790

79

... More
Erection of 11 KV GOAB switch with 200 A.12 KV rated voltage GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming to IS: 9921-Part1 to V as amended upto date and detailed specifications enclosed herewith. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufactures of the insulators and have minimum 320mm creepage distance and AB switches contacts shall be of copper/copper alloy

1

3971

3971

... More
Fixing of 11 KV HG fuse,200A, Horn gap type fuse I.TECHNICAL PARTICULARS: 1. Highest System voltage : 12 KV (R.M.S) 2. Impulse voltage withstand voltage : 75 KV (Peak) 3. One minute power frequency withstand voltage : 35 KV (R.M.S.) 4. Continuous current rating of the unit : 200 Amps

1

3368

3368

... More
Erection of 9 KV, 5A Lightning Arrestor, pole mounted.9 KV, 5 KA nominal discharge current Metal Oxide gapless distribution class lightning arrestor conforming to IEC-60099-4 and IS 3070 Part 3 1993 as amended upto date suitable for 11 KV 50 HZ effectively earthed neutral system with necessary mounting arrangements and connector suitable to connect ACSR conductor upto overall diameter 12.30 mm.The marking of the Lightning Arrestors shall be as per IS

3

522

174

... More
Erection of MS Distribution box complete.M. S. distribution box MCCB of 400 Amps capacity Kit Kat Porcelain fuse carrier and base with extended terminals.

1

8795

8795

... More
Removing and Refixing of Distribution Transformer 100 KVA. of Distribution Transformer 100 KVA.11/0.433KV, 50HZ, outdoor type, oil immersed, core type, Oil Natural Air Natural Cool type, Delta Star Dy11 aluminium wound, distribution transformer (without taps) as per specification.

1

16525

16525

... More
Removing and Refixing of Distribution Transformer 100 KVA. Distribution Transformer Metering Unit, with DLMS protocol

1

1608

1608

... More
Laying of XLPE armoured XLPE 3 1/2 core 95 sq.mm. The armoured cable of sizes as required i.e. 90Sq.mm that shall be suitably terminated at both the ends with appropriate sizes of Aluminum lugs duly crimped using a crimping tool. Appropriate sizes of GJ/ Brass nut / bolts/washers shall be used for firmly connecting the same to the MCCB's/Transformer L.T. Bushings/Outgoing LT feeder

144

21456

149

... More
Laying of XLPE armoured cable 1 core 120 sq.mm.The unarmoured cable shall be of 1 core and of sizes as required i.e. 120Sq.mm that shall be suitably terminated at both the ends with appropriate sizes of Aluminum lugs duly crimped using a crimping tool. Appropriate sizes of G.I / Brass nut / bolts / washers shall be used for firmly connecting the same to the MCCB’s/Transformer L.T. Bushings/Outgoing LT feeder

48

4560

95

... More
Providng of HDGI nuts & bolts various sizes. G.I. Hexagonal head bolts and hexagonal nuts conforming to IS 1363 part 1 to 3 1992 as amended upto date.The bolts and nuts shall be hot dip galvanized as per IS: 2629-1985 as amended upto date

45

1350

30

... More
Providing of Aluminum crimping lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade 1E of IS 5082-1969 suitable for aluminium cables of following sizes: 1. 120 Sq.mm.

8

704

88

... More
Providing of Aluminum crimping lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade 1E of IS 5082-1969 suitable for aluminium cables of following sizes: 1. 95 Sq.mm.

12

780

65

... More
Removing of 11KV Guard cross arm, ISMC channel 75 x 40 mm, 1.5mts long

1

246

246

... More
Removing of HDGI cut point cross arm ISMC Channel, 75x40mm, 1.3mts long with clamps

1

273

273

... More
Removing of HDGI Top fitting cross arm ISMC Channel, 75x40mm, 0.7mts long

1

114

114

... More
Removing of 11KV Disc Insulators 70KN with HDGI metal parts

3

562

187.5

... More
Removing of ACSR 'WEASEL' of size ( 6/1/2.59mm) for road crossing and HT/LT line crossing

0.28

995

3555

... More
Removing of HDGI stay clamps for RCC pole 9 mtr L.A

10

395

39.5

... More
Removing of GI Xarm clamp LA for 9.0 mtr poles

12

270

22.5

... More
Removing of GI Xarm clamp SA for 9.0 mtr poles

2

45

22.5

... More
Removing of 11 KV GOAB switch with 200 A.

1

1985

1985.5

... More
Removing of 11 KV HG fuse,200A.

1

1684

1684

... More
Removing of 9 KV, 5A Lightning Arrestor, pole mounted.9 KV, 5 KA

3

261

87

... More
Removing of MS Distribution box complete.

1

4397

4397.5

... More
Removing of XLPE armoured cable 3 1/2 core 95 sq.mm.

144

10728

74.5

... More
Removing of XLPE unarmoured cable1 core 120 sq.mm

48

2280

47.5

... More
Removing of 9mtr RCC Pole

2

4408

2204

... More
Removing of 2 pin X arm with clamp

13

1508

116

... More
Removing of 4 pin X arm with clamp

25

3262

130.5

... More
Removing of LT Pin Insulator with GI Pin

40

3460

86.5

... More
Removing of HDGI Structure Materials

210

4935

23.5

... More
Removing of LT Shackle with Metal Parts

40

4160

104

... More
Removing of AA ANT Conductor

2.31

7662

3317

... More
Removing of AA GNAT conductor

1.17

3616

3091



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.