Electricity Department Tender
View complete overview of Goa Electricity Department Tender
Costs
EMD
₹ 1,08,935Document Cost
₹ 1,000Tender Fee
₹ 6,000
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_ED_12360_1Bid Award Id
ViewTender No
Tender-62/Div-V (2023-24)Tender Authority
Electricity Department ViewPurchaser Address
-Website
http://eprocure.goa.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply of Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete.
10
27300
2730
... More
Supply of G.O.A.B. Switch 36 KV 800 Amps (double break) G.O.A.B. Switch 36 KV (double break)
Rated Freq.: 50 Hz, System Neutral Earthing: Solidly earthed, No. of phase(poles): 3Nos, Temp. rise (Deg. C) As per standards IS/IEC, Safe duration of overload (in Minutes), 150 % of rated current: 5 minutes, 120 % of rated current: 30 minutes
Rated voltage: 36 KV rms, Type of isolator (AB) DBCR
Rated normal current 630 /800/1200 Amps., Rated short time withstand current of MS & EB for 3 second 25 KA rms.
Rated peak current of MS & EB: 63 KA peak
Rated short circuit make current of EB: 63 KA peak 63
Derating factor: Unity,
Basic Insulation Level:
Lightening Impulse withstand voltage(KV peak)
a) Pole to earth & between poles: 170
b) Across isolating distance: 195
Rated power freq. withstand voltage (KV rms)
a) Pole to earth & between poles 70
b) Across isolating distance: 80
Min. creepage distance: 900 mm
Phase to phase spacing for installation: 1500 mm
Min. clearances (mm)
a) Phase to earth: 430 mm
b) Between rotating post and fixed post on one phase: 485mm
Height of centre line of terminal pad above ground level (mm): 3885mm
Special Requirements: Earthing blades(EB) shall be capable to discharge the trapped charge of the line. Isolator main switch(MS) shall be required to make or break the line charging current when no significant change in voltage occurs across the isolating distance on account of make or break
2
289620
144810
... More
Supply of 33KV, 630A, 25KA, 3 way Outdoor Load Break Switch comprising of 3 nos. 630A isolators
1
2478000
2478000
... More
Supply of HDG Stay set complete with HDG stay rod & HDG Plate, break insulator 8 KV, HDG Stay clamps, HDG nut bolts & HDG Stay wire 7/10 swg. Etc.. For 13 mtr long Rail pole
4
30800
7700
... More
Supply of 33 KV Pin Insulators. 33 KV brown glazed porcelain pin insulator with minimum failing load of 10 KN and the Minimum creepage distance of 840 mm conforming to IS 731-1971 as amended upto date.Insulators shall be marked and packed as per IS.Routine tests and acceptance tests as per IS shall be carried at the manufacturers works and test results shall be furnished before supply of materials.
3
5088
1696
... More
Supply of G.I. Pin for 33 KV Pin Insulators. Forged G. I. Pin conforming to IS 2486 part 1 & 2 as amended upto date suitable for 33 KV porcelain pin insulators conforming to IS: 731/71 as amended upto date. G. I. pin shall be supplied along with one suitable G. I. hexagonal nut and G. I. spring washer.Pin shall conform to reference L230N fig. 6 of IS 2486 part 2. Dimension ‘X’ in said fig. shall be 150 mm (screwed 100 mm). Minimum failing load of pin shall be 10 KN.G. I. pins and nuts shall be hot dip galvanized as per IS: 2629/66 as amended up to date. The washers shall be electro galvanized.Acceptance tests and Routine tests shall be carried out at the manufacturers works and test reports shall be furnished before supply of materials.
3
1638
546
... More
Supply of Disc insulators ball and socket type, type ‘A’ porcelain brown glazed duly cemented at factory with MCI socket cap, forged steel ball pin and supplied with Phosphor bronze “W” split pin as per IS 731-1971 as amended upto date. Minimum failing load. Pin ball diameter 16 mm.Minimum Creepage distance 320 mm. Ferrous parts shall be galvanized as per relevant IS. Insulator shall be marked as per IS. Acceptance tests and routine tests shall be carried out as per IS by the manufacturer and test results shall be furnished by the manufacturer before supply of materials. 90KN (x 3 no)
18
82998
4611
... More
Supply of Disc insulators 90 KN 3-bolted type hardware fitting 90KN suitable for 11KV ball and socket type disc insulators of 18mm pin, failing load of 90KN. Conform to IS-2486 Part 1-1993, 2486 Part 2-1989 as amended upto date. suitable for wolf conductor
18
28206
1567
... More
Supply of ACSR conductor WOLF for Line & Busbar
0.2
21232
106161
... More
Supply of "TEE connector" suitable for ACSR 'Wolf'
15
6585
439
... More
Supply of XLPE cable 33KV 3C X 400 sq.mm armoured type A2XFY (E) for Linking from 33KV LBS to 33KV OH line
300
1080000
3600
... More
Supply of H.S.33 KV Indoor Termination Kit for 3C 400 Sq mm XLPE
4
89313
22328.4
... More
Supply of H.S.33 KV Outdoor Termination Kit for 3C 400 Sq mm XLPE
3
96960
32320
... More
Supply of RCC protective covers of size 600mm long x 250mm width and 50mm thick capable of bearing load of 135Kg. And covered with earth/ sand upto depth of 0.15mts. Confirming to IS 1255-1967 at non-road crossing. (as per CEE approved drawing, enclosed)
500
63500
127
... More
Supply of Sand for cushioning of HT underground cables.(0.2 mtr depth X 0.4 mtr width X 500 mtr long )
40
86800
2170
... More
Supply of GI Pipe 150mm, class B
12
20172
1681
... More
Supply of Enamelled danger boards 33KV
4
992
248
... More
Numbering /painting of LT and HT network poles
4
417
104.33
... More
Civil Work for RMU
-
-
-
... More
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size for foundations.
7
38885
5555
... More
Centering and shuttering including struttings, propping etc and removal of formwork .
17
9571
563
... More
12mm cement plaster 1:4 (1 - cement: 4 - fine sand) for foundations.
6
882
147
... More
Cost of Erection
-
-
-
... More
Erection of RCC poles 11.00 mtr long as per Drawing CEE/C-698
4
34400
8600
... More
Erection of HDGI Structural material for DP including Line Channels, Support channels, clamps, N&B Etc (Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas)
1500
70500
47
... More
Erection of Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete.
10
24440
2444
... More
Erection of G.O.A.B. Switch 36 KV 800 Amps (double break) G.O.A.B. Switch 36 KV (double break)
Rated Freq.: 50 Hz, System Neutral Earthing: Solidly earthed, No. of phase(poles): 3Nos, Temp. rise (Deg. C) As per standards IS/IEC, Safe duration of overload (in Minutes), 150 % of rated current: 5 minutes, 120 % of rated current: 30 minutes
Rated voltage: 36 KV rms, Type of isolator (AB) DBCR
Rated normal current 630 /800/1200 Amps., Rated short time withstand current of MS & EB for 3 second 25 KA rms.
Rated peak current of MS & EB: 63 KA peak
Rated short circuit make current of EB: 63 KA peak 63
Derating factor: Unity,
Basic Insulation Level:
Lightening Impulse withstand voltage(KV peak)
a) Pole to earth & between poles: 170
b) Across isolating distance: 195
Rated power freq. withstand voltage (KV rms)
a) Pole to earth & between poles 70
b) Across isolating distance: 80
Min. creepage distance: 900 mm
Phase to phase spacing for installation: 1500 mm
Min. clearances (mm)
a) Phase to earth: 430 mm
b) Between rotating post and fixed post on one phase: 485mm
Height of centre line of terminal pad above ground level (mm): 3885mm
Special Requirements: Earthing blades(EB) shall be capable to discharge the trapped charge of the line. Isolator main switch(MS) shall be required to make or break the line charging current when no significant change in voltage occurs across the isolating distance on account of make or break
2
19768
9884
... More
Erection of 33KV, 630A, 25KA, 3 way Outdoor Load Break Switch comprising of 3 nos. 630A isolators
1
13500
13500
... More
Erection of HDG Stay set complete with HDG stay rod & HDG Plate, break insulator 8 KV, HDG Stay clamps, HDG nut bolts & HDG Stay wire 7/10 swg. Etc.. For 13 mtr long Rail pole
4
10888
2722
... More
Erection of 33 KV Pin Insulators. 33 KV brown glazed porcelain pin insulator with minimum failing load of 10 KN and the Minimum creepage distance of 840 mm conforming to IS 731-1971 as amended upto date.Insulators shall be marked and packed as per IS.Routine tests and acceptance tests as per IS shall be carried at the manufacturers works and test results shall be furnished before supply of materials.
3
468
156
... More
Erection of G.I. Pin for 33 KV Pin Insulators. Forged G. I. Pin conforming to IS 2486 part 1 & 2 as amended upto date suitable for 33 KV porcelain pin insulators conforming to IS: 731/71 as amended upto date. G. I. pin shall be supplied along with one suitable G. I. hexagonal nut and G. I. spring washer.Pin shall conform to reference L230N fig. 6 of IS 2486 part 2. Dimension ‘X’ in said fig. shall be 150 mm (screwed 100 mm). Minimum failing load of pin shall be 10 KN.G. I. pins and nuts shall be hot dip galvanized as per IS: 2629/66 as amended up to date. The washers shall be electro galvanized.Acceptance tests and Routine tests shall be carried out at the manufacturers works and test reports shall be furnished before supply of materials.
3
456
152
... More
Erection of Disc insulators ball and socket type, type ‘A’ porcelain brown glazed duly cemented at factory with MCI socket cap, forged steel ball pin and supplied with Phosphor bronze “W” split pin as per IS 731-1971 as amended upto date. Minimum failing load. Pin ball diameter 16 mm.Minimum Creepage distance 320 mm. Ferrous parts shall be galvanized as per relevant IS. Insulator shall be marked as per IS. Acceptance tests and routine tests shall be carried out as per IS by the manufacturer and test results shall be furnished by the manufacturer before supply of materials. 90KN (x 3 no)
18
10530
585
... More
Erection of Disc insulators 90 KN 3-bolted type hardware fitting 90KN suitable for 11KV ball and socket type disc insulators of 18mm pin, failing load of 90KN. Conform to IS-2486 Part 1-1993, 2486 Part 2-1989 as amended upto date. suitable for wolf conductor
18
4050
225
... More
Removing of ACSR conductor 'RACOON' 6 +1 / 4.09 mm nominal aluminium area 80mm² (250 amps max. at 45° C)
0.5
2583
5167
... More
Erection of ACSR conductor WOLF for Line & Busbar
0.2
2756
13784
... More
Erection of XLPE cable 33KV 3C X 400 sq.mm armoured type A2XFY (E) for Linking from 33KV LBS to 33KV OH line
300
111300
371
... More
Removing & Re-laying of XLPE cable 33KV 3C X 400 sq.mm armoured type A2XFY
200
111300
556.5
... More
Erection of H.S.33 KV Indoor Termination Kit for 3C 400 Sq mm XLPE
4
16563
4140.75
... More
Erection of H.S.33 KV Outdoor Termination Kit for 3C 400 Sq mm XLPE
3
13172
4390.75
... More
Earthwork excavation in foundation trenches ( not exeeding 1.5 mts in depth including opening of roads,chambers/pavements and soiling,ramming,levelling of bottoms, making bottom,freed from stones including removing out the excavated soil/material as directed within a lead of 40mtrs (1.3 mtr depth X 0.4 mtr width X 300 mtr + 1.3x0.6x200 mtr long ) in soft soil.
312
146016
468
... More
Erection of RCC protective covers of size 600mm long x 250mm width and 50mm thick capable of bearing load of 135Kg. And covered with earth/ sand upto depth of 0.15mts. Confirming to IS 1255-1967 at non-road crossing. (as per CEE approved drawing, enclosed)
500
42000
84
... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge.
264
31680
120
... More
Erection of GI Pipe 150mm, class B
12
2184
182
... More
Erection of Enamelled danger boards 33KV
4
228
57