Electricity Department Tender

View complete overview of Goa Electricity Department Tender

Electricity Department Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date23 Aug 2024
Closing Date11 Sep 2024
Tender Amount₹ 13,29,90,345 
Notes
Download

Costs

  • EMD

    ₹ 23,29,903
  • Document Cost

    ₹ 1,500
  • Tender Fee

    ₹ 6,000

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
SETC of 11KV, 3 core 95sq.mm aluminium, XLPE insulated, flat wire armoured, 11 KV (Earthed) Cable, type A2XFY conforming I.S. 7098 PART 2 and carrying ISI MARK through conventional open trenching method in any type of soil including hard laterite.

736

829472

1127

... More
Supply of 3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 1CB Extensible/Non-Extensible Two (2) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 and One (1) vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.

22

12430000

565000

... More
Supply of 4 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 4LBS Extensible/Non-Extensible Four (4) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6. SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU, Current Transformer and Numerical Relay with communication in all CB module.Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.

1

690000

690000

... More
Supply of 3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 3LBS Extensible/Non Extensible Three (3) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU , modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.

5

2720000

544000

... More
Supply of 11KV, 3 phase, Outdoor type, heat shrinkable end termination kit complete, for 11 KV XLPE cable of size 3 x 300sq.mm including sockets/lugs/connectors etc. (for 11KV take-off gantry at 33/11KV sub-station & for interlinking with other 11KV Overhead feeders)

1

11667

11667

... More
Supply of 11KV, 3 phase, Indoor type, heat shrinkable end termination kit complete, for 11 KV XLPE cable of size 3 x 300 sq.mm including sockets/lugs/connectors etc. for connecting RMU for main section side

71

627640

8840

... More
Supply of 11KV 3 phase indoor terminating kit complete, for 11 KV XLPE cable of size 3 x 95 sq.mm including sockets/lugs/connectors etc. for connecting 11KV end of Distribution transformer .

23

154813

6731

... More
Supply of 11KV 3 phase outdoor terminating kit complete, for 11 KV XLPE cable of size 3 x 95 sq.mm including sockets/lugs/connectors etc. for connecting RMU for main section side .

23

233496

10152

... More
Supply of straight through joint complete for 11 KV XLPE cable of size 3 x 300 sq.mm including sockets/lugs/connectors etc. .

53

1566627

29559

... More
Supply of Cable route Markers (for entire 11 KV cable route length ) as per drawing.

206

108768

528

... More
Supply and Erection of Warning tape for entire 11 KV route length.

20.56

308400

15000

... More
Supply and laying of fine river sand of approved quality for cushioning of HT underground cables laid by conventional Open Trenching Method.

1713.24

3717730

2170

... More
Supply of Protective Concrete Slab of size 480mm length x 250mm width x 50mm (+/-2mm) thick as a protective cover for underground cables.

50211

6778485

135

... More
Supply and laying of wire cut Bricks for 11KV Cable seperation.

31975

303762

9.5

... More
Supply of G.I. earthing pipe, 2500mm long, 40mm nominal dia, class B, perforated for RMU's The pit shall be filled with homogenous mixture of 20Kgs of Charcoal, 20Kgs of salt and sand /soil with Brick masonary Chambers The work includes excavation, backfilling & spreading of excavated surplace earth evenly at RMU's. [Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas]

56

247968

4428

... More
Supply of HDGI flat of size 25mm x 5mm for earthing of RMU's [Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas]

280

32480

116

... More
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size for foundations of RMU's)

14

77770

5555

... More
Supply & Providing of Centering and shuttering including struttings, propping etc. and removal of formwork for a) Foundations, footings, bases of columns and mass concrete for RMU's

98

55174

563

... More
Supply & Providing of 12 mm cement plaster 1:4 ( 1 cement: 4 fine sand) for foundations of RMU's

19.6

2881

147

... More
Supply and laying of RCC Hume Pipe 150mm dia with required no. of collars, for road crossing.

500

158500

317

... More
Supply of GI pipe,150mm dia for bridge crossing.

688

1156528

1681

... More
Supply & providing of Rubble Packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete for single and Double Circuit 11KV Cable trench.

2970.9

6568659

2211

... More
Cost of Erection

-

-

-

... More
Erection Testing & Commissioning of 11KV, 3 core, 300 sq.mm. aluminium, XLPE insulated, flat wire armoured, 11 KV (Earthed) Cable, type A2XFY conforming I.S. 7098 PART 2 and carrying ISI MARK through conventional open trenching method in any type of soil including hard laterite

27038

9246996

342

... More
Erection Testing & Commissioning of 11KV, 3 core 95sq.mm aluminium, XLPE insulated, flat wire armoured, 11 KV (Earthed) Cable, type A2XFY conforming I.S. 7098 PART 2 and carrying ISI MARK through conventional open trenching method in any type of soil including hard laterite.

736

146464

199

... More
Erection Testing & Commissioning of3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 1CB Extensible/Non-Extensible Two (2) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 and One (1) vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.

22

213840

9720

... More
Erection Testing & Commissioning of 4 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 4LBS Extensible/Non-Extensible Four (4) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6. SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU, Current Transformer and Numerical Relay with communication in all CB module.Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.

1

9720

9720

... More
Erection Testing & Commissioning of 3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 3LBS Extensible/Non Extensible Three (3) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU , modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.

5

48600

9720

... More
Erection Testing & Commissioning of 11KV, 3 phase, Outdoor type, heat shrinkable end termination kit complete, for 11 KV XLPE cable of size 3 x 300sq.mm including sockets/lugs/connectors etc. (for 11KV take-off gantry at 33/11KV sub-station & for interlinking with other 11KV Overhead feeders)

1

2718

2718

... More
Erection Testing & Commissioning of 11KV, 3 phase, Indoor type, heat shrinkable end termination kit complete, for 11 KV XLPE cable of size 3 x 300 sq.mm including sockets/lugs/connectors etc. for connecting RMU for main section side

71

180908

2548

... More
Erection Testing & Commissioning of 11KV 3 phase indoor terminating kit complete, for 11 KV XLPE cable of size 3 x 95 sq.mm including sockets/lugs/connectors etc. for connecting 11KV end of Distribution transformer .

23

58374

2538

... More
Erection Testing & Commissioning of 11KV 3 phase outdoor terminating kit complete, for 11 KV XLPE cable of size 3 x 95 sq.mm including sockets/lugs/connectors etc. for connecting RMU for main section side .

23

60904

2648

... More
Erection of straight through joint complete for 11 KV XLPE cable of size 3 x 300 sq.mm including sockets/lugs/connectors etc.

53

196789

3713

... More
Erection of Cable route Markers (for entire 11 KV cable route length ) as per drawing.

206

52736

256

... More
Laying, testing & commisioning of 11KV, 3 core, 300 sq.mm. aluminium, XLPE cables by trenchless technology by adopting horizontal directional drilling (HDD method). The work includes preparation of site, Boring as well as drawing of cable in Hard/Laterite stone with minimum 8'' bore size, including Supply and erection of HDPE pipe 110mm, PN6, PE80, wall thickness 6.5mm (minimum) as per IS 4984:1995 amendment 2016. The depth shall be 1.650m to 1.850m (1650mm-1850mm) only except at entry and exist pits where minimum depth shall be 1200mm and permanent Re-instatement of dug up pits excavated during cable laying as per Goa PWD specifications.

1200

4320000

3600

... More
Excavation in any type of soil including hard laterite soil by mechanical means( hydraulic excavator)/manual means for laying of HT/ LT cables of various sizes including excavation for equipment foundations i.e for RMU's including getting out the excavated soil and disposal of surplus excavated soil. All types of rock including laterite/Hard rock, blasting prohibited 1) Size 1.1 x 0.40 x cable length mts for laying of 1 run.

3874.64

2956350

763

... More
Excavation in any type of soil including hard laterite soil by mechanical means( hydraulic excavator)/ manual means for laying of HT/ LT cables of various sizes including excavation for equipment foundations i.e for RMU's including getting out the excavated soil and disposal of surplus excavated soil. All types of rock including laterite/Hard rock, blasting prohibited 2) Size 1.1 x 0.60 x cable length mts for laying of 2 run.

3309.9

2525453

763

... More
Excavation in any type of soil including hard laterite soil by mechanical means( hydraulic excavator)/manual means for laying of HT/ LT cables of various sizes including excavation for equipment foundations i.e for RMU's including getting out the excavated soil and disposal of surplus excavated soil. All kinds of soil a)Size 1.1 x 0.40 x cable length mts for laying of 1 run.

1910.56

894142

468

... More
Excavation in any type of soil including hard laterite soil by mechanical means( hydraulic excavator)/manual means for laying of HT/ LT cables of various sizes including excavation for equipment foundations i.e for RMU's including getting out the excavated soil and disposal of surplus excavated soil. All kinds of soil b) Size 1.1 x 0.60 x cable length mts for laying of 2 run.

976.8

457142

468

... More
Refilling of excavated soil in the foundations, trenches etc. with avialable excavated earth in layers not exceeding 20 cm depth, cosolidating each layer by ramming and watering lead upto 50 M and all lifts and disposal of surplus earth in cable trenches and foundations of equipments.

8242.5

989100

120

... More
Laying of Protective Concrete Slab of size 480mm length x 250mm width x 50mm (+/-2mm) thick as a protective cover for underground cables.

50211

3012660

60

... More
Erection of G.I. earthing pipe, 2500mm long, 40mm nominal dia, class B, perforated for RMU's The pit shall be filled with homogenous mixture of 20Kgs of Charcoal, 20Kgs of salt and sand /soil with Brick masonary Chambers The work includes excavation, backfilling & spreading of excavated surplace earth evenly at RMU's.

56

149240

2665

... More
Erection of HDGI flat of size 25mm x 5mm for earthing of RMU's

280

13440

48

... More
Laying of RCC Hume Pipe 150mm dia with required no. of collars, for road crossing.

500

75500

151

... More
Laying of GI pipe,150mm dia for bridge crossing.

688

125216

182

... More
Carrying out detailed physical survey of the area including detailed GPS survey which includes indicating and marking location of other utilities if any, furnishing of optimum and economical route and design for layong of HT, XLPE cables of various size and accessories, including plotting on the scaled land base map of size 1:1000 indicating all features and submitting drilling profile indicating proposed plan for open trenching,road,nullah,culvet, over bridge, rail crossing, or any other special crossing. The work shall include digging of trial pits at suitable intervals and re-instatement of dug-up area of trial pits. The detailed documents as well as the write-up shall be furnished in 02 nos. of hard copies and soft copies for approval.Upon approval fresh 06 Nos. of hard copies alongwith a soft copy shall be furnished duly corrected. On completion, the contractor has to submit final survey map with longitude and latitude of each every item with other details for asset mapping.

20.56

308400

15000

... More
Cost of Erection

-

-

-

... More
Removal of 11 mtr RCC Pole.

46

225400

4900

... More
Removal of 9 mtr RCC Pole.

382

1126900

2950

... More
Removal of 90lb/yd Rail pole 11mtrs long

5

52625

10525

... More
Removing of HDGI 11 KV 'V' Shape cross arm with clamps & nut bolts.

263

33006

125.5

... More
Removing of Cut Point cross arm channel 75 x 40 mm, 1.3 mts long with clamp & nut bolt.

59

14514

246

... More
Removing of Cut Point cross arm channel 75 x 40 mm, 3 mts long with clamp & nut bolt.

299.88

7047

23.5

... More
Removing of Guard 'X' arm of channel of ISMC 75(75 x 40 mm) 1.5 mts long with clamp & nut bolt.

50

13650

273

... More
Removing of Top fitting for LT /11KV RCC Pole with nut bolts.

279

12694

45.5

... More
Removing of 11 KV Disc Insulators 45 KN with H.D.G.I. Metal parts.

834

138444

166

... More
Removing of 11 KV Pin Insulator with H.D.G.I. Pin.

279

21204

76

... More
Removing of ACSR 'WEASEL' Conductor

89.27

490957

5500

... More
11KV GOAB Switch 200Amp

4

7942

1985.5



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.