Electricity Department Tender

View complete overview of Goa Electricity Department Tender

Electricity Department Tender

Works
Energy, Oil and Gas
Eprocure
Opening Date9 Dec 2024
Closing Soon26 Dec 2024
Tender Amount₹ 6,82,40,873 
Notes
Download

Costs

  • EMD

    ₹ 13,64,817
  • Document Cost

    ₹ 1,500
  • Tender Fee

    ₹ 6,000

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
3 WAY RMU, 11 KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 1CB :Extensible/Non-Extensible Two (2) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 and One(1) Vacum Circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.Auxillary PT as per specification shall be provided in RMU

7

620750

4345250

... More
3 WAY RMU, 11 KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 3LBS:Extensible/Non-Extensible Two (3) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.Auxillary PT as per specification shall be provided in RMU

7

585000

4095000

... More
Supply and termination of indoor type end termination Raychem heat shrinkable kit for 11KV XLPE cable of size 3x300 sq.mm including sockets / lugs / connectors etc. alongwith cable glands at 11KV Ring Main Unit & two way on load switch (DEOS).

36

8840

318240

... More
Supply and termination of indoor type end termination Raychem heat shrinkable kit for 11KV XLPE cable of size 3x95 sq.mm including sockets / lugs / connectors etc. alongwith cable glands at 11KV Ring Main Unit.

7

6731

47117

... More
Supply and termination of out door type end termination Raychem heat shrinkable kit for 11KV XLPE cable of size 3x95 sq.mm including sockets / lugs / connectors etc. alongwith cable glands at Transformer centre AB Switch

7

10152

71064

... More
Supply, erection, testing & commissioning of XLPE heat shrinkable straight through jointing kit for 300 sq.mm, 3 core, 11KV XLPE cable.

16

29559

472944

... More
Supplying and filling in plinth under floors, trenches including watering ramming consolidating, dressing, complete, sand (of size 0.2x 0.6 x 8070) Deduct for 11 KV Cable ( 3.14x0.05x0.05)x total length x no. of run Total Sand

582.25

2170

1263482.5

... More
Disposal of surplus earth

746.48

125

93922.11

... More
Supply and laying of underground cable protective cover as per specification as given below : The concrete slab shall be machine made using semi-dry concrete that is batched in a fully auomatic PLC controlled concrete batching plant and cast in a fully automatic "Vibro-Press" machine with a high vibration frequency and hydraulic pressure of 40 MT, the size of the slab shall be 480 mm x 250 mm x 50 mm, (+/- 2 mm) and the concrete grade shall be M30 adhering to IS 456:2000 and shall have a minimum crusing strength of 30 N/mm2 (28 days strength) when tested. ( L ) 300 / 0.48 (length of bricks) x 4 run

16813

135

2269755

... More
Providing of Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipe line trenches and other foundations complete, for work of laying of Double circuit 11 KV Cable trench ( 0.2 x 0.9x 1.00) i.e. 0.18 per RM

1452.6

2211

3211698.6

... More
Supply and laying of precast RCC hume pipe of size 150 mm with required number of collars using cement mortar 1:2 for road crossing and at any other crossing as ordered.

84

317

26628

... More
Warning Tape

8.07

15000

121050

... More
Supply and installing of cable route Makers (for entire route length) [Proposed one for every 50 mtrs]

240

528

126720

... More
GI Pipe 150 mm, class B,riser pipe for 300 sq. mm. cable support , 5 Mts. for O/H Feeder I/L.

30

1681

50430

... More
GI Riser Pipe 100mm, class B, for 95 sq. mm. cable support , 3.5Mts. for each DP.

36

624

22464

... More
Supply and erection of earthing with 40mm dia x 2.5 mts long class 'B' GI pipe, with charcoal, salt, inserted in pit excavated of size not less than 500mm x 500mm x 2400mm as per Drg No. CEE/E-829( 2 for each RMU & DEOS).

28

2730

76440

... More
HDG Strip 25mm x 5 mm for connecting earthing for RMU & DEOS ( 6 mts for each RMU )

168

116

19488

... More
SETC laying of 11 KV UG cables size 300 sq.mm & 95 sq.mm by trenchless technology by adopting hotizontal directional drilling (HDD method). The work includes preparation of site, boring as well as drawing of cable in Hard /laterite stone with minimum 9" bore size, including supply and erection of HDPE pipe 200 mm PN6 PE100 Thickness 8 mm

3130

3600

11268000

... More
COST OF ERECTION

-

-

-

... More
Erection of 11KV , 3 core 300 sq.mm. A2XFY Al. armoured XLPE cable through conventional open trenching method in any type of soil including hard laterite (excluding HDD quantity i.e. 3130).

8790

342

3006180

... More
Erection, Testing & commissioning of 3 core, 95 sq.mm Aluminium, XLPE insulated armoured, 11KV (earthed neutral) Cable for connecting to the distribution transformer centres and 11 KV HT installations and any other equipment's. (from RMU to Transformer / HT Consumers and single transformer)

120

199

23880

... More
3 WAY RMU, 11 KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 1CB :Extensible/Non-Extensible Two (2) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 and One(1) Vacum Circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.Auxillary PT as per specification shall be provided in RMU

7

9720

68040

... More
3 WAY RMU, 11 KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 3LBS:Extensible/Non-Extensible Two (3) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.Auxillary PT as per specification shall be provided in RMU

7

9720

68040

... More
Supply and termination of indoor type end termination Raychem heat shrinkable kit for 11KV XLPE cable of size 3x300 sq.mm including sockets / lugs / connectors etc. alongwith cable glands at 11KV Ring Main Unit & two way on load switch (DEOS).

36

2548

91728

... More
Supply and termination of indoor type end termination Raychem heat shrinkable kit for 11KV XLPE cable of size 3x95 sq.mm including sockets / lugs / connectors etc. alongwith cable glands at 11KV Ring Main Unit.

7

2538

17766

... More
Supply and termination of out door type end termination Raychem heat shrinkable kit for 11KV XLPE cable of size 3x95 sq.mm including sockets / lugs / connectors etc. alongwith cable glands at Transformer centre AB Switch

7

2648

18536

... More
Supply, erection, testing & commissioning of XLPE heat shrinkable straight through jointing kit for 300 sq.mm, 3 core, 11KV XLPE cable.

16

3713

59408

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in hard rock where blasting prohibited (of size 1.10 x 0.4 x (1 Run ) 8070 Mts)

3550.8

763

2709260.4

... More
Re filling the pipeline foundation trenches plinth sides foundation etc with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by the engineer in Charge (of size 0.9 x 0.4 x 8070) Deduct for RCC slab - [(0.6*0.25*0.05)*no of slabs(5697)] Total refilling

2804.33

120

336519.6

... More
Laying of underground cable protective cover as per specification as given below : The concrete slab shall be machine made using semi-dry concrete that is batched in a fully auomatic PLC controlled concrete batching plant and cast in a fully automatic "Vibro-Press" machine with a high vibration frequency and hydraulic pressure of 40 MT, the size of the slab shall be 480 mm x 250 mm x 50 mm, (+/- 2 mm) and the concrete grade shall be M30 adhering to IS 456:2000 and shall have a minimum crusing strength of 30 N/mm2 (28 days strength) when tested. ( L ) 300 / 0.48 (length of bricks) x 4 run

16813

60

1008780

... More
Laying of precast RCC hume pipe of size 150 mm with required number of collars using cement mortar 1:2 for road crossing and at any other crossing as ordered.

84

108

9072

... More
Supply and installing of cable route Makers (for entire route length) [Proposed one for every 50 mtrs]

240

256

61440

... More
GI Pipe 150 mm, class B,riser pipe for 300 sq. mm. cable support , 5 Mts. for O/H Feeder I/L.

30

182

5460

... More
GI Riser Pipe 100mm, class B, for 95 sq. mm. cable support , 3.5Mts. for each DP.

36

71

2556

... More
Supply and erection of earthing with 40mm dia x 2.5 mts long class 'B' GI pipe, with charcoal, salt, inserted in pit excavated of size not less than 500mm x 500mm x 2400mm as per Drg No. CEE/E-829( 2 for each RMU & DEOS).

28

2444

68432

... More
HDG Strip 25mm x 5 mm for connecting earthing for RMU & DEOS ( 6 mts for each RMU )

168

48

8064

... More
Estimate-2.The work of dismantling of 11 kV HT line of 11 KVTuem feeder from Tuem Sub station

-

-

-

... More
Removing of RCC pole 9.0 mtr long

110

2950

324500

... More
Removing of HDG cut point channel of ISMC 75x40x7.3mm 1.3 mtrs long with HDG clamps & HDG nut bolts etc for 9.0 mtrs long RCC pole.

28

274

7686

... More
Removing of HDG 11 KV 'V' shape cross arm with HDG clamps & HDG nut bolts etc. for 9.0 mt long RCC pole

90

197

17775

... More
Removing of HDG top fitting cross arm of channel ISMC 75x40x6 mm 0.7 mtrs long along with HDG clamps & HDG nut bolts etc. for 9.0 mtrs long RCC pole

110

142

15675

... More
Removing of 11 KV pin insulator with HDG pin

320

76

24320

... More
Removing of 11 KV Disc insulator 45 KN with HDGI metal parts

180

166

29880

... More
Removing of ACSR Weasel Conductor 6/1/2.59

15.5

5500

85250

... More
Removing of 95 sq mm Ariel bunched cable

6

22221

133326

... More
Civil estimate for the work of RMU foundation for laying underground cable for 11 KV Tuem feeder under sub div - I Pernem.

-

-

-

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 min width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : b)All types of Ordinary rock including all types of laterite rock, blasting prohibited

105.6

639

67478.4

... More
Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete.

19.2

2211

42451.2

... More
Providing & laying cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded granitic or basaltic stone aggrt. 20 mm. nominal size) excluding cost of centering, shuttering and finishing in: a)All works upto plinth level

9.6

6325

60720

... More
Providing and laying in position (1:11/2:3) Reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinfrocement (1 cement: 1½ coarse sand: 3 graded stone agg 20mm nominal size) a)All works upto plinth level

36.2

7178

259843.6

... More
Providing TMT steel reinforcement bars of (SAIL, TATA, VIZAG, JSW Steel Ltd.))(Confirming to IS 1786 of 1986) for RCC work (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in allthe floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member.

4448.35

105

467076.75

... More
Centering & shuttering including Strutting, Propping & removal of forms for:

-

-

-

... More
i)Foundations, Footings, Bases for columns

22.4

407

9116.8

... More
ii)Vertical surfaces such as retaining walls, return walls, Partitions, walls (any thickness) including attached Pilasters, Buttresses, Plinth and string courses, Fillets and the like

234.05

479

112109.95

... More
12mm cement plaster 1:4 (1 cement : 4 fine sand)

113.25

223

25254.75

... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge.

58.59

245

14354.55



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.