Electricity Department Tender

View complete overview of Goa Electricity Department Tender

Electricity Department Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date4 Oct 2024
Closing Date14 Oct 2024
Tender Amount₹ 20,25,977 
Notes
Download

Costs

  • EMD

    ₹ 40,520
  • Document Cost

    ₹ 500
  • Tender Fee

    ₹ 4,052

Summary

Work Of Erection Of 200 Kva Plinth Mounted Dtc Near Our Lady Mount Carmel Church Madhlawada Harmal Under Jurisdiction Of S/o Mandrem , Sub Div Iii Agarwada , Div Vii Mapusa

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of MS Distribution Box along with 12 Nos 200 A kit kat fuse and MCCB odf 400A, 415 Volts. The box shall be fabricated with MS sheet 12 gauge with overlaping rain proof slit ventilators on both side of the distiburion box with wire mash to prevent enty of insects with pin head door hinges locking arrangements and shall have require no of bus bar made out of alluminium stripa 40x 6 mm, other & accessories.

1

63140

63140

... More
Supply and erection of G.I earthing pipe 2500mm long, 40mm dia class B fabricated and perforated filled with homogenous mixture of 20Kgs of salt and sand / soil inclusive of excavation, backfilling & spreading of excavated earth evenly as per Drg No. CEE/E-829. The work includes excavation of pit in any type of soil classified under Soft Strata of Annexure A of CPWD-8.

8

2730

21840

... More
400/5 LT CT ring type,measuring CT coil of rating400/5A,Class I accuracy,50Hz,660V,Burden:15VA conferming to IS2705/1992 as amended up to date.3ph,4W,Electronic Trivector Meter,LT CT operated 3X240v /5A,50Hz,class 0.5s,Category a9forDTC) with Rs232 and Optical port and compliance to BIS ICs Doc: ETD 13(6211) april,2010.Polemounted MS Box(outdoor type )Electronic Meter as per Drawing No. EE/VIII/64(REV).1.1KV Multistrand copperconductor ,XLPE insulated,armoured control cable conferming to relevent IS amended up to date and of size 4 core x 2.5sq,mm.High grade 3/4" brass gland for 4 core 2.5sqmm. cable

1

25688

25688

... More
MODEM as per MRT specification

1

6000

6000

... More
FRP Fencing complete with Gate as per specification for Distribution Transformer (Size 4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

1

76667

76667

... More
Supply, erection, testing & commissioning of termination of indoor type end termination Raychem heat shrinkable kit for 11KV XLPE cable of size 300sqmm including sockets / lugs / connectors etc alongwith cable glands at 11KV Ring Main Unit.(for RMU)

2

8840

17680

... More
Supply, Erection, Testing & commissioning of 3 core, 95 sq.mm Aluminium, 11KV, XLPE insulated armoured Cable for connecting to the distribution transformer centres and 11 KV HT installations and any other equipments.

15

1127

16905

... More
Supply, erection, testing & commissioning of termination of indoor type end termination heat shrinkable kit for 11KV XLPE cable of size 95sqmm including sockets / lugs / connectors etc alongwith cable glands at 11KV Ring Main Unit.

1

6731

6731

... More
Supply, erection, testing & commissioning of termination of outdoor type end termination heat shrinkable kit for 11KV XLPE cable of size 95sqmm including sockets / lugs / connectors etc alongwith cable glands at Transformer centre AB Switch

1

10152

10152

... More
XLPE Single Core unarmoured 50 sq mm 1.1 KV grade

50

83

4150

... More
XLPE Single Core unarmoured XLPE 300 sq mm 1.1 KV grade

48

477

22896

... More
Aluminium lugs for 300 sq mm XLPE cable

8

124

992

... More
XLPE single Core urmoured XLPE 185 sq mm 1.1 KV grade(3Nos feeder, 15mtrsx4 runsx2)

120

245

29400

... More
Aluminium lugs for 185 sq mm XLPE cable

8

78

624

... More
Painting of pole numbers with yellow black paint

5

104

521.65

... More
GI Pipe 50mm Class B

18

424

7632

... More
Supply of 7.5 Mts long RCC pole

5

6092

30460

... More
HDG LT 4 pin cross arm channel type HDG clamps & HDG nut bolts etc for 7.5 Mts long RCC pole

15

1384

20763

... More
HDG LT 2 pin cross arm channel type HDG clamps & HDG nut bolts etc for 7.5 Mts long RCC pole

15

844

12663

... More
Supply of LT Pin insulator with Metal parts

60

263

15780

... More
Supply of LT Shackle insulator with metal part

75

372

27900

... More
Supply of ANT conductor

2.64

48086

126947.04

... More
Supply of GNAT conductor

2.64

25293

66773.52

... More
Supply of HDG stay set complete for 7.5 mtr. long RCC pole.

5

4068

20340.5

... More
COST OF ERECTION

-

-

-

... More
Transportation, hoisting, erection, testing and commissioning of 200KVA, 11kv/0.4kv Distribution Transformer, level II losses, Aluminium wounding with bimetalic terminal connector, Enenry efficiency level II as per IS:1180(Part-I):2014

1

15638

15638

... More
3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 1CB Extensible/Non-Extensible Two (2) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 and One (1) vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.

1

9720

9720

... More
Erection, testing and commisioning of MS Distribution Box along with 12 Nos 200 A kit kat fuse and MCCB odf 400A, 415 Volts. The box shall be fabricated with MS sheet 12 gauge with overlaping rain proof slit ventilators on both side of the distiburion box with wire mash to prevent enty of insects with pin head door hinges locking arrangements and shall have require no of bus bar made out of alluminium stripa 40x 6 mm, other & accessories.

1

8795

8795

... More
Erection of G.I earthing pipe 2500mm long, 40mm dia class B fabricated and perforated filled with homogenous mixture of 20Kgs of salt and sand / soil inclusive of excavation, backfilling & spreading of excavated earth evenly as per Drg No. CEE/E-829. The work includes excavation of pit in any type of soil classified under Soft Strata of Annexure A of CPWD-8.

8

2444

19552

... More
400/5 LT CT ring type,measuring CT coil of rating400/5A,Class I accuracy,50Hz,660V,Burden:15VA conferming to IS2705/1992 as amended up to date.3ph,4W,Electronic Trivector Meter,LT CT operated 3X240v /5A,50Hz,class 0.5s,Category a9forDTC) with Rs232 and Optical port and compliance to BIS ICs Doc: ETD 13(6211) april,2010.Polemounted MS Box(outdoor type )Electronic Meter as per Drawing No. EE/VIII/64(REV).1.1KV Multistrand copperconductor ,XLPE insulated,armoured control cable conferming to relevent IS amended up to date and of size 4 core x 2.5sq,mm.High grade 3/4" brass gland for 4 core 2.5sqmm. cable

1

1072

1072

... More
Erection of FRP Fencing complete with Gate as per specification for Distribution Transformer (Size 4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

1

35000

35000

... More
Erection, testing & commissioning of termination of indoor type end termination Raychem heat shrinkable kit for 11KV XLPE cable of size 300sqmm including sockets / lugs / connectors etc alongwith cable glands at 11KV Ring Main Unit.(for RMU)

2

2548

5096

... More
Erection, Testing & commissioning of 3 core, 95 sq.mm Aluminium, 11KV, XLPE insulated armoured Cable for connecting to the distribution transformer centres and 11 KV HT installations and any other equipments.

15

199

2985

... More
Erection, testing & commissioning of termination of indoor type end termination heat shrinkable kit for 11KV XLPE cable of size 95sqmm including sockets / lugs / connectors etc alongwith cable glands at 11KV Ring Main Unit.

1

2538

2538

... More
Erection, testing & commissioning of termination of outdoor type end termination heat shrinkable kit for 11KV XLPE cable of size 95sqmm including sockets / lugs / connectors etc alongwith cable glands at Transformer centre AB Switch

1

2648

2648

... More
XLPE Single Core unarmoured 50 sq mm 1.1 KV grade

50

56

2800

... More
XLPE Single Core unarmoured XLPE 300 sq mm 1.1 KV grade

48

218

10464

... More
Aluminium lugs for 300 sq mm XLPE cable

8

101

808

... More
XLPE single Core urmoured XLPE 185 sq mm 1.1 KV grade(3Nos feeder, 15mtrsx4 runsx2)

120

170

20400

... More
Aluminium lugs for 185 sq mm XLPE cable

8

95

760

... More
GI Pipe 50mm Class B

18

43

774

... More
Erection of 7.5 Mts long RCC pole

5

3689

18445

... More
HDG LT 4 pin cross arm channel type HDG clamps & HDG nut bolts etc for 7.5 Mts long RCC pole

15

305

4575

... More
HDG LT 2 pin cross arm channel type HDG clamps & HDG nut bolts etc for 7.5 Mts long RCC pole

15

276

4140

... More
Erection of LT Pin insulator with Metal parts

60

173

10380

... More
Erection of LT Shackle insulator with metal part

75

208

15600

... More
Stringing of ANT conductor

2.64

6634

17513.76

... More
Stringing of GNAT conductor

2.64

6183

16323.12

... More
Erection of HDG stay set complete for 7.5 mtr. long RCC pole.

5

2403

12019

... More
Removing of deteriorated 7.5 Mts long RCC pole

5

1844

9222.5

... More
Removing of deteriorated HDG LT 2 pin cross arm channel type HDG clamps & HDG nut bolts etc for 7.5 Mts long RCC pole

15

152

2287.5

... More
Removing of deteriorated HDG LT 2 pin cross arm channel type HDG clamps & HDG nut bolts etc for 7.5 Mts long RCC pole

15

138

2070

... More
Removing of deteriorated LT Pin insulator with Metal parts

60

86

5190

... More
Removing of deteriorated LT Shackle insulator with metal part

75

104

7800

... More
Removing of deteriorated ANT conductor

2.64

3317

8756.88

... More
Removing of deteriorated GNAT conductor

2.64

3091

8161.56

... More
Civil work for Transformer plinth

-

-

-

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 min width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : b)All types of Ordinary rock including all types of laterite rock, blasting prohibited

7.81

639

4990.59

... More
Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete.

1.47

2211

3250.17

... More
Providing & laying cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded granitic or basaltic stone aggrt. 20 mm. nominal size) excluding cost of centering, shuttering and finishing in: a)All works upto plinth level

0.74

6325

4680.5

... More
Centering and shuttering including struttings, propping etc. and removal of formwork for a)Foundations, footings, bases for columns and mass concrete.

1.52

407

618.64

... More
Providing and laying in position (1:11/2:3) Reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinfrocement (1 cement: 1½ coarse sand: 3 graded stone agg 20mm nominal size) a)All works upto plinth level

5.19

7178

37253.82

... More
Providing TMT steel reinforcement bars of (SAIL, TATA, VIZAG, JSW Steel Ltd.))(Confirming to IS 1786 of 1986) for RCC work (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in allthe floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member.

391.78

105

41136.9

... More
Centering & shuttering including Strutting, Propping & removal of forms for: i)Foundations, Footings, Bases for columns

24.39

407

9926.73

... More
12mm cement plaster 1:4 (1 cement : 4 fine sand)

17.75

223

3958.25

... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge.

4.2

245

1029

... More
TRANSPORTATION AND CARRIAGE OF MATERIALS (A) By tipper truck including loading, unloading and stacking (A) Lime,building rubbish, manure sludge, moorum excavated rock ( ii ) Earth (upto 5 km)

3.61

252

910.66

... More
Civil work for RMU Foundation

-

-

-

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 min width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : b)All types of Ordinary rock including all types of laterite rock, blasting prohibited

6.27

639

4006.53

... More
Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete.

1.14

2211

2520.54

... More
Providing & laying cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded granitic or basaltic stone aggrt. 20 mm. nominal size) excluding cost of centering, shuttering and finishing in: a)All works upto plinth level

0.57

6325

3605.25

... More
Providing and laying in position (1:11/2:3) Reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinfrocement (1 cement: 1½ coarse sand: 3 graded stone agg 20mm nominal size) a)All works upto plinth level

2.26

7178

16222.28

... More
Providing TMT steel reinforcement bars of (SAIL, TATA, VIZAG, JSW Steel Ltd.))(Confirming to IS 1786 of 1986) for RCC work (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in allthe floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member.

243.75

105

25593.75

... More
Centering & shuttering including Strutting, Propping & removal of forms for:

-

-

-

... More
i)Foundations, Footings, Bases for columns

1.28

407

520.96

... More
ii)Vertical surfaces such as retaining walls, return walls, Partitions, walls (any thickness) including attached Pilasters, Buttresses, Plinth and string courses, Fillets and the like

14.18

479

6792.22

... More
12mm cement plaster 1:4 (1 cement : 4 fine sand)

6.86

223

1529.78

... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge.

3.45

245

845.25



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.