Electricity Department Tender

View complete overview of Goa Electricity Department Tender

Electricity Department Tender

Works
Civil And Construction
Road Construction
Eprocure
Opening Date3 Sep 2024
Closing Date13 Sep 2024
Tender Amount₹ 54,72,683 
Notes
Download

Costs

  • EMD

    ₹ 1,09,454
  • Document Cost

    ₹ 1,000
  • Tender Fee

    ₹ 6,000

Summary

Tender For The Work Of Shifting Of Htlt Line And 5 Nos Dtcs Along The Proposed Road Widening From Bicholim Bus Stand To Muslimwada Police Quarters As Per Request Of Exe. Engr, Pwd, And Shifting Of 200kva Sankalp Udhyan Dtc Under S/d I, Bicholim.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
HDG L.T. 4 pin cross arm Channel type for 9/7.5 mts long RCC pole

83

92047

1109

... More
HDG L.T. 2 pin cross arm Channel type

78

44382

569

... More
HDGI 'X'arm clamps for RCC pole 9 mts L.A/S.A

121

32186

266

... More
HDGI 'X'arm clamps for RCC pole 7.5 mts L.A/S.A

40

7360

184

... More
G.I nut & Bolts 100X 16mm

69.2

15777

228

... More
G.I. Stay & plate LT/11 KV line

26

62504

2404

... More
G.I. turn buckle with eye bolt

26

17602

677

... More
HDGI stay wire 7/10 SWG,

95.56

13473

141

... More
Break insulator 8 KV(44KN)

26

4576

176

... More
HDGI stay clamps for RCC Pole 9 Mtrs L.A/S.A

26

12766

491

... More
HDGI stay clamps for RCC Pole7.5 Mtrs L.A/S.A

4

1244

311

... More
LT shackle Insulator

250

41750

167

... More
Metal parts for LT schackle insulators

250

51250

205

... More
L.T. pin insulators

219

29784

136

... More
GI pin for LT pin insulator.

219

27813

127

... More
Stringing of AAC " ANT" conductor

8.56

411616

48086

... More
Stringing of AAC '' GNAT '' Conductor

8

202344

25293

... More
B) Estimate for removing and erection of DTC

-

-

-

... More
Supply and laying 11KV, 3 core 300 sq.mm A2XFY Aluminium Armoured XLPE Cable open Trench

40

93520

2338

... More
11KV 3 phase indoor terminating kit to be used with cables - 300 sq.mm.

2

17680

8840

... More
Supply and erection of straight through joint for 300 sq.mm cable (Considering length of the cable for one cable drum as 500m)

2

59118

29559

... More
G.I. Earthing pipe 8' long 40 mm. Dia class B, Fabricated & perforated including alternate layers 30 Cm. Thick of charcoal, salt, & earth (charcoal & salt 10 Kgs. each for per pit) inclusive of excavation, backfilling and spreading of excavated earth evenly.

30

81900

2730

... More
S&E of GI earthing strip of size 25x5 mm for connecting earthing pipe to other equipment

200

23200

116

... More
M.S. Distribution Box With 400Amps MCCB and Kit-Kat Fuse

5

315700

63140

... More
XLPE Single core unarmoured 300 sqmm 1.1 kv grade

240

114480

477

... More
XLPE Single core unarmoured 120 sqmm 1.1 kv grade

624

102336

164

... More
AL. Crimping lug 300 sq.mm

40

4960

124

... More
AL. Crimping lug 120 sq.mm

60

3240

54

... More
Providing and laying in position cement concrete 1:2:4 ( 1 cement :2 coarse sand :4 graded granitic or basaltic stone aggregate 40mm nominal size) excluding cost of centering,shuttering and finishing (for plinths of 400KVA transformer, RMU,LV panel)

32

177760

5555

... More
Centering & shuttering including struttings, propping etc & remonal of formwork

71.25

40113

563

... More
12mm cement plaster 1:4 (1 - cement: 4 - fine sand) for foundations.

59.1

8687

147

... More
Brick work using common burnt clay building bricks in cement mortar 1:4 ( 1-cement: 4 - coarse sand) in foundation and plinth (b) with bricks of class designation 75 kgs/sq.mm (wire cut bricks)

7

51912

7416

... More
FRP Fencing complete with Gate as per specification for Distribution Transformer ( Size x 4Mx3Mx2M) with Concreting for FRP fencing Supports with plinth (0.3x0.3x0.5) Cu.mx12nos.Each ratio 1:3:3

5

383335

76667

... More
HDGI DP Structural Material

90

15210

169

... More
G.O.A.B Switch 11KV 400Amps

1

30322

30322

... More
Cost of Erection

-

-

-

... More
A) Erection of line to the proposed location

-

-

-

... More
RCC pole 9 mtrs long

36

212400

5900

... More
RCC pole 7.5 mtrs long

22

114400

5200

... More
HDG L.T. 4 pin cross arm Channel type for 9/7.5 mts long RCC pole

83

21663

261

... More
HDG L.T. 2 pin cross arm Channel type

78

18096

232

... More
HDGI 'X'arm clamps for RCC pole 9 mts L.A/S.A

121

5445

45

... More
HDGI 'X'arm clamps for RCC pole 7.5 mts L.A/S.A

40

1280

32

... More
G.I nut & Bolts 100X 16mm

69.2

2076

30

... More
G.I. Stay & plate LT/11 KV line

26

46254

1779

... More
G.I. turn buckle with eye bolt

26

6942

267

... More
HDGI stay wire 7/10 SWG,

95.56

5924

62

... More
Break insulator 8 KV(44KN)

26

2522

97

... More
HDGI stay clamps for RCC Pole 9 Mtrs L.A/S.A

26

2054

79

... More
HDGI stay clamps for RCC Pole7.5 Mtrs L.A/S.A

4

276

69

... More
LT shackle Insulator

250

26000

104

... More
Metal parts for LT schackle insulators

250

26000

104

... More
L.T. pin insulators

219

21681

99

... More
GI pin for LT pin insulator.

219

16206

74

... More
Stringing of AAC " ANT" conductor

8.56

88168

10300

... More
Stringing of AAC '' GNAT '' Conductor

8

72800

9100

... More
Removing and erection of LED light 130 watts

54

84240

1560

... More
Removing and erection of HDGI Street light clamps for 40mm pipe (top/bottom)

108

7614

70.5

... More
Removing and erection of GI bent pipe 1.5 mtr X 40 mm

54

7209

133.5

... More
B) Estimate for removing and erection of DTC

-

-

-

... More
Supply and laying 11KV, 3 core 300 sq.mm A2XFY Aluminium Armoured XLPE Cable open Trench

40

13680

342

... More
11KV 3 phase indoor terminating kit to be used with cables - 300 sq.mm.

2

5096

2548

... More
Supply and erection of straight through joint for 300 sq.mm cable (Considering length of the cable for one cable drum as 500m)

2

7426

3713

... More
Removing and erection of 200 KVA 11kv/.4kv Distribution Transformers level II losses, Copper Winding, with Bimetallic Terminal Connectors, Energy Efficiency Level-II as per IS: 1180 (Part-I): 2014, suitable for outdoor use and for plinth mounting (close type bushing)

5

117285

23457

... More
Removing and erection 3-WAY RMU, 11KV, 630 Amps, Outdoor, SF6 Ring Main Unit with two Load Break Switches and one Circuit Breaker confirming to IS & complete with fault passage indicator

1

14580

14580

... More
Removing and re laying 11KV, 3 core 95 sq.mm A2XFY Aluminium Armoured XLPE Cable (RMU to DTC

100

29850

298.5

... More
Removing and erection of Distribution Transformer Metering unit with DLMS/COSEM protocol energy meter with modem

5

8040

1608

... More
G.I. Earthing pipe 8' long 40 mm. Dia class B, Fabricated & perforated including alternate layers 30 Cm. Thick of charcoal, salt, & earth (charcoal & salt 10 Kgs. each for per pit) inclusive of excavation, backfilling and spreading of excavated earth evenly.

30

73320

2444

... More
S&E of GI earthing strip of size 25x5 mm for connecting earthing pipe to other equipment

200

9600

48

... More
M.S. Distribution Box With 400Amps MCCB and Kit-Kat Fuse

5

43975

8795

... More
XLPE Single core unarmoured 300 sqmm 1.1 kv grade

240

52320

218

... More
XLPE Single core unarmoured 120 sqmm 1.1 kv grade

624

59280

95

... More
AL. Crimping lug 300 sq.mm

40

4040

101

... More
AL. Crimping lug 120 sq.mm

60

5280

88

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : b) All types of Ordinary rock including all types of laterite rock, blasting prohibited : DC Trench (1.1*0.6*30)

5

3815

763

... More
FRP Fencing complete with Gate as per specification for Distribution Transformer ( Size x 4Mx3Mx2M) with Concreting for FRP fencing Supports with plinth (0.3x0.3x0.5) Cu.mx12nos.Each ratio 1:3:3

5

175000

35000

... More
Removing of Rcc Pole 11M Long

6

29400

4900

... More
Removing of M.S. Rail poles 90 lb/yd 11 mtrs long

4

42100

10525

... More
Removing of HDGI DP Structural Material

1370

32195

23.5

... More
Removing of G.O.A.B Switch 11KV 200Amps

5

9927

1985.5

... More
Removing of H.G.Fuse Unit 11KV 200 Amps

5

8420

1684

... More
Removing of Lightning/Surge Arrestors 9KA,5KA

15

1305

87

... More
Removing of M.S. Distribution Box With 400Amps MCCB and Kit-Kat Fuse

5

21987

4397.5

... More
Removing of armoured cable 3.5C X 240 sqmm

60

8160

136

... More
Removingof armoured cable 3.5C X 120 sqmm

156

13728

88

... More
C) Estimate for removing of HT/LT line

-

-

-

... More
MS Rail pole 90 lb/yd 11 mrs long

12

126300

10525

... More
Rcc Pole 11M Long

4

19600

4900

... More
Erection of RCC pole 9 mtrs long

26

76700

2950

... More
Erection of RCC pole 7.5 mtrs long

17

44200

2600

... More
HDG L.T. 4 pin cross arm Channel type for 9/7.5 mts long RCC pole

80

10440

130.5

... More
HDG L.T. 2 pin cross arm Channel type

73

8468

116

... More
HDGI X arm clamps for 90 lb Rail pole LA/SA

52

1794

34.5

... More
X-Arm Clamp 11M Pole LA

12

390

32.5

... More
HDGI 'X'arm clamps for RCC pole 9 mts L.A/S.A

94

2115

22.5

... More
HDGI 'X'arm clamps for RCC pole 7.5 mts L.A/S.A

40

640

16

... More
LT shackle Insulator

215

11180

52

... More
Metal parts for LT schackle insulators

215

11180

52

... More
L.T. pin insulators

220

10890

49.5

... More
GI pin for LT pin insulator.

220

8140

37

... More
11KV Disc Insulator, 45 KN

39

3003

77

... More
HDG Metal Parts, 45 KN, 3 Bolted Typed.

39

3471

89

... More
11 KV Pin Insulator

33

1254

38

... More
G.I. Pin For 11KV Pin Insulator

33

1254

38

... More
Stringing of AAC " ANT" conductor

7.28

37492

5150

... More
Stringing of AAC '' GNAT '' Conductor

7.2

32760

4550

... More
HDGI 11KV V-Shape X Arm Of Channel Ismc (75X40Mm)

11

1859

169

... More
HDGI Top Fitting Cross Arm Ismc Channel (75X40Mm),0.7M Long For 11KV

11

1254

114

... More
HDG Cut Point Channel Of 1.3 Mtr. Long Of Channel Ismc 75 X 40 X 7.3 Mm

12

2952

246

... More
HDG guard cross arm of channel of 1.5 mts for 11 mts long RCC pole

15

4095

273

... More
Acsr Conductor Weasel

3

16500

5500

... More
HDGI DP Structural Material

90

4230

47

... More
G.O.A.B Switch 11KV 400Amps

1

3989

3989

... More
Removing and erection of LED light 130 watts

48

74880

1560

... More
Removing and erection of HDGI Street light clamps for 40mm pipe (top/bottom)

96

6768

70.5

... More
Removing and erection of GI bent pipe 1.5 mtr X 40 mm

48

6408

133.5

... More
II) Shifting of 200KVA Sankalp Udhyan DTC along with associated line and material along road side in the jurisdiction of Section Office Bicholim, Sub Division I(U), Bicholim.

-

-

-

... More
Cost of Material

-

-

-

... More
GI Stay rod with plate LT/11KV

1

2404

2404

... More
GI Turn buckle with eye bolt 11KV

1

677

677

... More
Stay wire 7/10 SWG wire

3.74

527

141

... More
Break Insulator, 8KV

1

176

176

... More
GI Nut & Bolts 100 X16mm

2

456

228

... More
HDGI stay clamps for RCC pole 9 mts long

1

491

491

... More
HDG L.T. 4 pin cross arm Channel type

2

2218

1109

... More
HDG L.T. 2 pin cross arm Channel type

2

1138

569

... More
HDGI 'X' arm clamps for RCC pole 9 mtr long

4

1064

266

... More
L.T. Shackel insulators

10

1670

167

... More
Metal Parts for LT Shackel Insulator

10

2050

205

... More
XLPE Single core unarmoured 300 sqmm 1.1 kv grade

48

22896

477

... More
XLPE Single core unarmoured 120 sqmm 1.1 kv grade

144

23616

164

... More
AL. Crimping lug 300 sq.mm

8

992

124

... More
AL. Crimping lug 120 sq.mm

12

648

54

... More
200 KVA 11kv/.4kv Distribution Transformers level II losses, Copper Winding, with Bimetallic Terminal Connectors, Energy Efficiency Level-II as per IS: 1180 (Part-I): 2014, suitable for outdoor use and for plinth mounting (close type bushing)

1

377405

377405

... More
G.I. Earthing pipe 8' long 40 mm. Dia class B, Fabricated & perforated including alternate layers 30 Cm. Thick of charcoal, salt, & earth (charcoal & salt 10 Kgs. each for per pit) inclusive of excavation, backfilling and spreading of excavated earth evenly.

6

16380

2730

... More
S&E of GI earthing strip of size 25x5 mm for connecting earthing pipe to other equipment

40

4640

116

... More
Providing and laying in position cement concrete 1:2:4 ( 1 cement :2 coarse sand :4 graded granitic or basaltic stone aggregate 40mm nominal size) excluding cost of centering,shuttering and finishing (for plinths of 400KVA transformer, RMU,LV panel)

6.4

35552

5555

... More
Centering & shuttering including struttings, propping etc & remonal of formwork

14.25

8022

563

... More
12mm cement plaster 1:4 (1 - cement: 4 - fine sand) for foundations.

11.82

1737

147

... More
Brick work using common burnt clay building bricks in cement mortar 1:4 ( 1-cement: 4 - coarse sand) in foundation and plinth (b) with bricks of class designation 75 kgs/sq.mm (wire cut bricks)

1.4

10382

7416

... More
FRP Fencing complete with Gate as per specification for Distribution Transformer ( Size x 4Mx3Mx2M) with Concreting for FRP fencing Supports with plinth (0.3x0.3x0.5) Cu.mx12nos.Each ratio 1:3:3

1

76667

76667

... More
Cost of Erection

-

-

-

... More
RCC pole 9 mtrs long

1

4408

4408

... More
GI Stay rod with plate LT/11KV

1

1779

1779

... More
GI Turn buckle with eye bolt 11KV

1

267

267

... More
Stay wire 7/10 SWG wire

3.74

231

62

... More
Break Insulator, 8KV

1

97

97

... More
GI Nut & Bolts 100 X16mm

2

60

30

... More
HDGI stay clamps for RCC pole 9 mts long

1

79

79

... More
HDG L.T. 4 pin cross arm Channel type

2

522

261

... More
HDG L.T. 2 pin cross arm Channel type

2

464

232

... More
HDGI 'X' arm clamps for RCC pole 9 mtr long

4

180

45

... More
L.T. Shackel insulators

10

1040

104

... More
Metal Parts for LT Shackel Insulator

10

1040

104

... More
M.S. Distribution Box With 400Amps MCCB and Kit-Kat Fuse

1

8795

8795

... More
XLPE Single core unarmoured 300 sqmm 1.1 kv grade

48

10464

218

... More
XLPE Single core unarmoured 120 sqmm 1.1 kv grade

144

13680

95

... More
AL. Crimping lug 300 sq.mm

8

808

101

... More
AL. Crimping lug 120 sq.mm

12

1056

88

... More
200 KVA 11kv/.4kv Distribution Transformers level II losses, Copper Winding, with Bimetallic Terminal Connectors, Energy Efficiency Level-II as per IS: 1180 (Part-I): 2014, suitable for outdoor use and for plinth mounting (close type bushing)

1

15638

15638

... More
Removing and erection 3-WAY RMU, 11KV, 630 Amps, Outdoor, SF6 Ring Main Unit with two Load Break Switches and one Circuit Breaker confirming to IS & complete with fault passage indicator

1

14580

14580

... More
Removing and re laying 11KV, 3 core 95 sq.mm A2XFY Aluminium Armoured XLPE Cable (RMU to DTC

25

7462

298.5

... More
Removing and erection of Distribution Transformer Metering unit with DLMS/COSEM protocol energy meter with modem

1

1608

1608

... More
G.I. Earthing pipe 8' long 40 mm. Dia class B, Fabricated & perforated including alternate layers 30 Cm. Thick of charcoal, salt, & earth (charcoal & salt 10 Kgs. each for per pit) inclusive of excavation, backfilling and spreading of excavated earth evenly.

6

14664

2444

... More
S&E of GI earthing strip of size 25x5 mm for connecting earthing pipe to other equipment

40

1920

48

... More
FRP Fencing complete with Gate as per specification for Distribution Transformer ( Size x 4Mx3Mx2M) with Concreting for FRP fencing Supports with plinth (0.3x0.3x0.5) Cu.mx12nos.Each ratio 1:3:3

1

35000

35000

... More
Removing of 150 KVA 11kv/.4kv Distribution Transformers level II losses, Copper Winding, with Bimetallic Terminal Connectors, Energy Efficiency Level-II

1

7819

7819

... More
Removing of Rcc Pole 11M Long

2

8600

4300

... More
Removing of HDGI DP Structural Material

274

6439

23.5

... More
Removing of G.O.A.B Switch 11KV 200Amps

1

1985

1985.5

... More
Removing of H.G.Fuse Unit 11KV 200 Amps

1

1684

1684

... More
Removing of Lightning/Surge Arrestors 9KA,5KA

3

261

87

... More
Removing of RCC pole 9 mtrs long

1

2204

2204

... More
Removing of HDG L.T. 4 pin cross arm Channel type

2

261

130.5

... More
Removing of HDG L.T. 2 pin cross arm Channel type

2

232

116

... More
Removing of HDGI 'X' arm clamps for RCC pole 9 mtr long

4

90

22.5

... More
Removing of L.T. Shackel insulators

10

520

52

... More
Removing of Metal Parts for LT Shackel Insulator

10

520

52

... More
Removing of M.S. Distribution Box With 400Amps MCCB and Kit-Kat Fuse

1

4397

4397.5

... More
Removing of armoured cable 3.5C X 240 sqmm

12

1632

136

... More
Removingof armoured cable 3.5C X 120 sqmm

36

3168

88



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.