Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_ED_16890_1Bid Award Id
ViewTender No
Tender 07(24-25)Tender Authority
Electricity Department ViewPurchaser Address
-
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply of HDGI 'X' arm clamps for RCC Pole 7.5 mtr L.A.
4
736
184
Supply of HDGI 'X' arm clamps for RCC Pole 7.5 mtr S.A.
1
184
184
Supply of L.T. Shackle insulators with Metal parts
6
2232
372
Supply of L.T. Pin Insulators with G.I. Pin
6
1578
263
Supply of AAC conductor 'ANT'
0.36
-
-
Supply of AAC conductor 'GNAT'
0.05
-
-
Supply of LED streetlight fixture of 50 watts
10
-
-
Supply of GI bent pipe 1m x 25mm
10
-
-
Supply of HDGI streetlight clamps for 25mm pipe (top/bottom)
10
-
-
Supply of HDGI nuts and bolts
3
684
228
Supply of Earthing as per IS 3043/1966. including supply, erection, testing & comm. of HDGI pipe 8 ft long 40 mm dia class B, fabricated & perforated confirming to I.E. rules of 1956 including alternate layers 30cm thick of charcoal, salt & earth (charcoal & salt --20Kgs each per pit) inclusive of earthwork excavation of size 0.50x0.50x2.5m, backfilling & spreading of excavated earth evenly toget required earth resistance as per enclosed specification
2
5460
2730
Supply of HDGI Pipe 100mm, class B
20
16220
811
Supply of HDGI st. light clamps for 100mm pipe (top/bottom) for cable protection from ground to junction box
16
8032
502
Supply of Street Light Service Pillar made out of CRCA sheet with PU painted complete with 4 pole MCCB,3 pole MCBs, TP Contactors, Electonic/Digital cum mechanical dual Timer, connectors etc. complete as per enclosed specifications & approved make.
1
49474
49474
Supply of FRP junction box including 4way porcelain connector, cable gland etc
9
23751
2639
Supply of 2 x 3 core 1.5 sqmm copper flexible wire from junction box upto the fixture.
70
7560
108
Supply of PVC insulated PVC sheathed with aluminium conductor of 1.1 KV grade 4 core armoured cable direct in ground as required and directed by engineer in-charge CABLE OF SIZE 25 sq.mm.
370
95460
258
Earthwork excavation including opening of roads, chamber/pave-ments and soling, ramming, levelling of bottoms, making bottom freed from stones including removing out the excavated soil/materials as directed(0.9 x 0.45 x 330 )
133.65
-
-
Rubbel packing with hard laterite stone under floors including watering rammingand consol;idating etci in pipeline trenches and other foundations complete for: d) Double Circuit 11KV Cable trench i.e. 0.2 0.9 x 1.0 e 0.18 per RM
46.2
-
-
Supply of underground cable protective cover. The concrete slab shall be machine made using dry concrete that is batched in a fully automatic controlled concrete batching plant and cast in a automatic "Vibro-Press" machine with a 135.00 60.00 vibration frequency and hydraulic pressure MT, the size of the slab shall be 480mmx 50mm, (+/- 2mm) and the concrete grade shall M30 adhering to IS 456: 2000 and shall minimum crushing strength of 30 N/mm2 (28 strength) when tested
688
92880
135
Filling up of available excavated earth (excluding rock/stones) in trenches, plinth, sides, foundation etc. in layer not exceeding 0.2 mt. depth con-solidating each deposited layer by ramming and watering (0.3 x 0.45 x 1100)
103.95
-
-
Supplying and laying of sand (0.45 x 0.2 x 1100)
29.7
64449
2170
ERECTION , TESTING and COMMISSIONING
-
-
-
E,T&C of 7.5Mtr RCC Pole
8
29512
3689
E,T&C of HDGI 2 pin 'X' arm of 75 x 40 Channel
5
1160
232
E,T&C of HDGI 'X' arm clamps for RCC Pole 7.5 mtr L.A.
4
128
32
E,T&C of HDGI 'X' arm clamps for RCC Pole 7.5 mtr S.A.
1
32
32
E,T&C of L.T. Shackle insulators with Metal parts
6
1248
208
E,T&C of L.T. Pin Insulators with G.I. Pin
6
1038
173
E,T&C of AAC conductor 'ANT'
0.36
2388
6634
E,T&C of AAC conductor 'GNAT'
0.05
278
6183
E,T&C of LED streetlight fixture of 50 watts
10
4000
400
E,T&C of GI bent pipe 1m x 25mm
10
820
82
E,T&C of HDGI streetlight clamps for 25mm pipe (top/bottom)
10
420
42
E,T&C of HDGI nuts and bolts
3
90
30
Providing,testing&commissioning of Earthing as per IS 3043/1966. including supply, erection, testing & comm. of HDGI pipe 8 ft long 40 mm dia class B, fabricated & perforated confirming to I.E. rules of 1956 including alternate layers 30cm thick of charcoal, salt & earth (charcoal & salt --20Kgs each per pit) inclusive of earthwork excavation of size 0.50x0.50x2.5m, backfilling & spreading of excavated earth evenly toget required earth resistance as per enclosed specification
2
4888
2444
E,T&C of HDGI Pipe 100mm, class B
20
1840
92
E,T&C of HDGI st. light clamps for 100mm pipe (top/bottom) for cable protection from ground to junction box
16
752
47
E,T&C of Street Light Service Pillar made out of CRCA sheet with PU painted complete with 4 pole MCCB,3 pole MCBs, TP Contactors, Electonic/Digital cum mechanical dual Timer, connectors etc. complete as per enclosed specifications & approved make.
1
3946
3946
E,T&C of FRP junction box including 4way porcelain connector, cable gland etc
9
1674
186
E,T&C of 2 x 3 core 1.5 sqmm copper flexible wire from junction box upto the fixture.
70
3360
48
E,T&C of PVC insulated PVC sheathed with aluminium conductor of 1.1 KV grade 4 core armoured cable direct in ground as required and directed by engineer in-charge CABLE OF SIZE 25 sq.mm.
370
34780
94
Earthwork excavation including opening of roads, chamber/pave-ments and soling, ramming, levelling of bottoms, making bottom freed from stones including removing out the excavated soil/materials as directed(0.9 x 0.45 x 330 )
133.65
62548
468
Rubbel packing with hard laterite stone under floors including watering rammingand consol;idating etci in pipeline trenches and other foundations complete for: d) Double Circuit 11KV Cable trench i.e. 0.2 0.9 x 1.0 e 0.18 per RM
46.2
102148
2211
E,T&C of underground cable protective cover. The concrete slab shall be machine made using dry concrete that is batched in a fully automatic controlled concrete batching plant and cast in a automatic "Vibro-Press" machine with a 135.00 60.00 vibration frequency and hydraulic pressure MT, the size of the slab shall be 480mmx 50mm, (+/- 2mm) and the concrete grade shall M30 adhering to IS 456: 2000 and shall minimum crushing strength of 30 N/mm2 (28 strength) when tested
688
41280
60
Filling up of available excavated earth (excluding rock/stones) in trenches, plinth, sides, foundation etc. in layer not exceeding 0.2 mt. depth con-solidating each deposited layer by ramming and watering (0.3 x 0.45 x 1100)
103.95
12474
120
Supplying and laying of sand (0.45 x 0.2 x 1100)
29.7
-
-