Tender 02 (25-26) Work For Arranging Lt Power Supply To The Director Of Agriculture At Codar Farm For A Load Of 81.46 Kw By Erection Of New 100 Kva Dtc Under The Jurisdiction Of Bethoda Section Office, Sub-division-ii (ehv), Division-x, Ponda

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Sand for cushoning of HT underground cables. Single circuit cable sand required = (0.4*0.2*Length of trench - 3.14*0.10*0.10*Length of cable) Double circuit cable sand required = (0.6*0.2*Length of trench - 3.14*0.10*0.10*Length of cable*2 - 0.2*length of trench*0.1)

4.28

2170

9287.6

... More
Supply of 11KV, 3 Core 300 sq.mm A2XFY Aluminium Armoured XLPE cable through conventional open trenching method in any type of soil including hard laterite.

100

2595

259500

... More
Supply and erection of straight through joints for 300 sq.mm cable

2

29559

59118

... More
Supply and laying of underground cable protective cover as per specification as given below: The concrete slab shall be made using semi-dry concrete that is batched in a fully automatic PLC controlled concrete batching plant and cast in a fully automatic "Vibro-Press" machine with a high vibration frequency and hydraulic pressure of 40 MT, the size of the slab shall be 480mm X250mmX50mm.(+/-2mm) and the concrete grade shall be M30 adhering to IS 456:2000 aand shall have a minimum crushing strength of 30N/mm2 (28days strength) when tested.

186

135

25110

... More
Warning Tape

0.05

15000

750

... More
3Way RMU, 11 KV, 630 A, 21 KA 3 Sec, SF6 Outdoor RMU-2LBS + 1 CBExtensible/Non Extensible Two (2) Motor operated load break switches (LBSs) with manual orerated eathing switches in SF6 and one (1) vaccum circuit breaker with electrical closing and tripping along with disconnector and earthing switches SCADA compatible and base channel, battery charger along with batteries required for electrical operations of RMU is in the scope of the bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no 's per RMU current transformer and numerical relay with communication in all CB module . Suitable arrangement for mounting FRTU , modem or Ethernet switch /LIU along the battery, battery charger shall be provided in RMU. Auxillary PT as per specification shall be provided in RMU.

1

735000

735000

... More
11KV, 3 core, 95sq.mm, AL conductor, XLPE insulated, armoured cable (from the RMU to the transformer)

16

1240

19840

... More
11KV 3 phase indoor terminating kit to be used with cables - 300 sq.mm.

2

8840

17680

... More
11KV 3 phase indoor terminating kit to be used with cables- 95sq.mm.

1

6731

6731

... More
11KV 3 phase outdoor terminating kit including sockets at 11KV end of DT to be used with cables as per -95sq.mm.

1

10152

10152

... More
Cable Route marker

2

528

1056

... More
Earthing complete with 40mm GI Pipe, 2.5mts long along with 20kgs each salt, charcoal complete.

7

2730

19110

... More
HDGI flat of size 25mm X 5mm for eathing.

10

116

1160

... More
Bricks required between double circuit (0.2*0.1*0.1)

450

9

4275

... More
M.s Distribution Box with 200A MCCB & kitkat fuseS

1

48387

48387

... More
240 SQMM unarmoured XLPE 1.1KV grade

40

366

14640

... More
FRP fencing complete with gate as per specification for distribution Transformer (Size 4MX3MX2M) with concreting for FRP fencing supports with plinth (0.3X0.3X0.5) Cu m X 12 nos. Each ratio 1:3:6

1

76667

76667

... More
Erection Cost

-

-

-

... More
Earthwork in excavation by mechanical means(hydraulic excavator)/manual means over areas(exceeding 30cm in depth, 1.5 m in width as well as 10sq.m on plan) including disposalof excavated earth lead upto 50M and lift upto 1.5 m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in. (Open Trench metod for layiing UG cable) a. All kinds of soil

8.1

468

3790.8

... More
Earthwork in excavation by mechanical means(hydraulic excavator)/manual means over areas(exceeding 30cm in depth, 1.5 m in width as well as 10sq.m on plan) including disposalof excavated earth lead upto 50M and lift upto 1.5 m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in. (Open Trench metod for layiing UG cable) b. All type of ordinary rock including all types of laterite rock, blasting prohibited.

21.6

763

16480.8

... More
RCC Hume pipe 100mm dia with required no. of collars, for road crossig

15

77

1155

... More
GI Pipe 100 mm, class B for nalla crossing and for cable rising on D.P of DTC

5

92

460

... More
Supply of 11KV, 3 Core 300 sq.mm A2XFY Aluminium Armoured XLPE cable through conventional open trenching method in any type of soil including hard laterite.

100

342

34200

... More
Supply and erection of straight through joints for 300 sq.mm cable

2

3713

7426

... More
Supply and laying of underground cable protective cover as per specification as given below: The concrete slab shall be made using semi-dry concrete that is batched in a fully automatic PLC controlled concrete batching plant and cast in a fully automatic "Vibro-Press" machine with a high vibration frequency and hydraulic pressure of 40 MT, the size of the slab shall be 480mm X250mmX50mm.(+/-2mm) and the concrete grade shall be M30 adhering to IS 456:2000 aand shall have a minimum crushing strength of 30N/mm2 (28days strength) when tested.

186

60

11160

... More
Refilling the pipeline /foundation trenches plinth sides, foundation etc. with available excavated eath in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead up to 50 M and all lifts and disposal of surplus earth aas dirrected by Engineer in charge.

24.3

120

2916

... More
3Way RMU, 11 KV, 630 A, 21 KA 3 Sec, SF6 Outdoor RMU-2LBS + 1 CBExtensible/Non Extensible Two (2) Motor operated load break switches (LBSs) with manual orerated eathing switches in SF6 and one (1) vaccum circuit breaker with electrical closing and tripping along with disconnector and earthing switches SCADA compatible and base channel, battery charger along with batteries required for electrical operations of RMU is in the scope of the bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no 's per RMU current transformer and numerical relay with communication in all CB module . Suitable arrangement for mounting FRTU , modem or Ethernet switch /LIU along the battery, battery charger shall be provided in RMU. Auxillary PT as per specification shall be provided in RMU.

1

9720

9720

... More
11KV, 3 core, 95sq.mm, AL conductor, XLPE insulated, armoured cable (from the RMU to the transformer)

16

199

3184

... More
11KV 3 phase indoor terminating kit to be used with cables - 300 sq.mm.

2

2548

5096

... More
11KV 3 phase indoor terminating kit to be used with cables- 95sq.mm.

1

2538

2538

... More
11KV 3 phase outdoor terminating kit including sockets at 11KV end of DT to be used with cables as per -95sq.mm.

1

2648

2648

... More
Cable Route marker

2

256

512

... More
Earthing complete with 40mm GI Pipe, 2.5mts long along with 20kgs each salt, charcoal complete.

7

2444

17108

... More
HDGI flat of size 25mm X 5mm for eathing.

10

48

480

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width .as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in :(RMU Foundation) b) All types of Ordinary rock including all types of laterite rock. blasting prohibited

5

639

3195

... More
Providing and laying in position cement concrete 1:3:6 (1 cement : 3 coarse sand: 6 graded granitic or basaltic stone aggregate 20 mm nominal size) excluding cost of centering, stuttering and finishing :(RMU Foundation) a) All works upto plinth level

0.32

6325

2024

... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 km depth consolidating each layer rammming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in charge(RMU Foundation)

0.29

245

71.05

... More
Centering & Shuttering including strutting, oropping & removal of forms for:(RMU Foundation) i) Foundations, footings, bases for columns

1.84

407

748.88

... More
Centering & Shuttering including strutting, oropping & removal of forms for:(RMU Foundation) ii) Vertical surfaces such as retaining walls, return waals, partitions, walls (anythickness) including attached pilasters, Buttresses, Plinth and string courses, fillets ande the like

7.44

479

3563.76

... More
Providing and laying in position (1.11/2:3) reinforced cement concretye excluding the cost of centering, shuttering, and reinforcement(1 cement :1 1/2 coarse sand: 3 graded stone agg 20mm nominal size)(RMU Foundation) a) All works upto plinth level

0.27

7178

1938.06

... More
Providing and laying in position (1.11/2:3) reinforced cement concretye excluding the cost of centering, shuttering, and reinforcement(1 cement :1 1/2 coarse sand: 3 graded stone agg 20mm nominal size)(RMU Foundation) b) in walls (any thickeness), including attached pilasters, Buttresses, Plinth and string courses, fillets, columns, pillars, piers, posts and structs etc. upto floor five level

0.61

8034

4900.74

... More
Providing TMT steel reinforcement bars of (SAIL, TATA,VIZAG, JSW steel ltd.) (confirming to IS 1786 of 1986) for RCC work (Conforming to I.S 1786 of 1986) including bending , binding & placing in position in all the floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strngth is not les than that of surrounding concrete in the structural member.(RMU Foundation)

70.4

105

7392

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width .as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : (Transformer Plinth) b) All types of Ordinary rock including all types of laterite rock. blasting prohibited

1.47

639

939.33

... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 km depth consolidating each layer rammming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in charge(Transformer Plinth)

0.27

245

66.15

... More
Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete.(Transformer Plinth)

0.29

2211

641.19

... More
Providing and laying in position cement concrete 1:3:6 (1 cement : 3 coarse sand: 6 graded granitic or basaltic stone aggregate 20 mm nominal size) excluding cost of centering, stuttering and finishing :(Transformer Plinth) a) All works upto plinth level

0.19

6325

1201.75

... More
Providing and laying in position (1.11/2:3) reinforced cement concretye excluding the cost of centering, shuttering, and reinforcement(1 cement :1 1/2 coarse sand: 3 graded stone agg 20mm nominal size)(Transformer Plinth) a) All works upto plinth level

3.31

7178

23759.18

... More
Centering & Shuttering including strutting, oropping & removal of forms for: i) Foundations, footings, bases for columns

11.04

407

4493.28

... More
Providing TMT steel reinforcement bars of (SAIL, TATA,VIZAG, JSW steel ltd.) (confirming to IS 1786 of 1986) for RCC work (Conforming to I.S 1786 of 1986) including bending , binding & placing in position in all the floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strngth is not les than that of surrounding concrete in the structural member.(Transformer Plinth)

264.8

105

27804

... More
Steel work in welded in built up sections, truses and framed work including cutting, hoisting, fixing in position and applying a priming coat of red lead paint b) in tees, angles, flats and channels

0.16

13023

2083.68

... More
18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand) and top layer 6mm thick with cement plaster 1: 3 (1 cement : 3 coarse sand) finished with sponge.

8.64

329

2842.56

... More
M.s Distribution Box with 200A MCCB & kitkat fuseS

1

4687

4687

... More
240 SQMM unarmoured XLPE 1.1KV grade

40

200

8000

... More
FRP fencing complete with gate as per specification for distribution Transformer (Size 4MX3MX2M) with concreting for FRP fencing supports with plinth (0.3X0.3X0.5) Cu m X 12 nos. Each ratio 1:3:6

1

35000

35000

... More
100 KVA, 11/0.433KV 3PH outdoor type, oil immersed Aluminium wound level II distribution transformer

1

11017

11017



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.