Electricity Department Tender

View complete overview of Goa Electricity Department Tender

Electricity Department Tender

Works
Electrical and Electronics
Eprocure
Opening Date13 Nov 2023
Closing Date6 Dec 2023
Tender Amount₹ 32,18,635 
Notes
Download

Costs

  • EMD

    ₹ 64,373
  • Document Cost

    ₹ 500
  • Tender Fee

    ₹ 6,000

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Tender for SETC of 100KVA DTC with HTLT Line at Gadder Borim under subdivn II Div X Curti Ponda Goa
Tender for SETC of 100KVA DTC with HTLT Line at Gadder Borim under subdivn II Div X Curti Ponda Goa
Tender for SETC of 100KVA DTC with HTLT Line at Gadder Borim under subdivn II Div X Curti Ponda Goa.
Tender for SETC of 100KVA DTC with HTLT Line at Gadder Borim under subdivn II Div X Curti Ponda Goa
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of 150 sq.mm 3 and half Core XLPE unarmoured ,1.1KV grade cable

60

63420

1057

... More
Supply of 185 sq.mm Single Core XLPE unarmoured ,1.1KV grade cable

60

14700

245

... More
A2XFY Aluminium Armoured XLPE UG HT Cable and CABLE JOINTING &TERMINATION KITS

-

-

-

... More
Supply, Erection, Testing and Comissioning of 3 core, 300 sq.mm. aluminium, XLPE insulated, armoured, 11KV Cable.

300

701400

2338

... More
Supply, Erection, Testing and Comissioning of 3 core, 95sq.mm. aluminium, XLPE armoured, 11KV Cable.

22

24794

1127

... More
Supply, Erection, Testing and Comissioning of Outdoor type, heat shrinkable, three phase, end termination kit complete, for 11KV XLPE cable of size 3 x 95sq.mm .

1

10152

10152

... More
Supply, Erection, Testing and Comissioning of Indoor type, heat shrinkable, three phase, end termination kit complete, for 11KV XLPE cable of size 3 x 95sq.mm .

1

6731

6731

... More
Supply, Erection, Testing and Comissioning of Indoor type, heat shrinkable, three phase, end termination kit complete, for 11KV XLPE cable of size 3 x 300sq.mm.

4

35360

8840

... More
Supply, Erection, Testing and Comissioning of heat shrinkable, three phase, straight through jointing kit complete, for 11KV XLPE cable of size 3 x 300sq.mm.

2

59118

29559

... More
RING MAIN UNITS & LOAD BREAK SWITCH UNITS

-

-

-

... More
Supply of 11KV, 630 Amps, Outdoor, SF6 Ring Main Unit with two Load Break Switches and one Circuit Breaker.

1

625000

625000

... More
Supply of 11KV, 630 Amps, Outdoor, SF6 Ring Main Unit with three Load Break Switches .

1

615000

615000

... More
Route Markers, Warning Tapes, RCC Hume pipe and GI PIPE

-

-

-

... More
Supply of RCC Cable route marker

3

1584

528

... More
Supply, Laying of Warning Tapes (for entire route length) as per technical specification and drawing.

0.27

4050

15000

... More
Design, Supply & Erection of Medium duty, HDGI Class B pipe of nominal diameter 100 mm (alongwith HDGI bends wherever required) for bridge crossing, riser pipe for 95Sq.mm & 300Sq.mm XLPE Cable etc., as per technical specifications including supporting arrangement for the pipe and 11 KV Bay.

15

12165

811

... More
Open Trenching method:- Excavation of pit, laying of protective covers, RCC hume pipe, earthing, foundations for equipments etc

-

-

-

... More
Supply and laying of fine river sand of approved quality (except sandy soil) for cushioning of 11KV/LT underground cables.

13.4

29078

2170

... More
Providing and laying of PCC protective covers of size 0.4 mts long X 0.25 mts width and 50 mm thick, at non-road crossing & for partitioning Cable.

675

91125

135

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in :All types of Ordinary rock including all types of laterite rock, blasting prohibited ( RMU foundation plinth)

7.68

4907

639

... More
Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete. ( RMU foundation plinth)

0.52

1149

2211

... More
Providing & laying cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded granitic or basaltic stone aggrt. 20 mm. nominal size) excluding cost of centering, shuttering and finishing in:All works upto plinth level ( RMU foundation plinth)

0.52

3289

6325

... More
Centering & shuttering including Strutting, Propping & removal of forms for :Foundations, Footings, Bases for columns ( RMU foundation plinth)

2.12

862

407

... More
Centering & shuttering including Strutting, Propping & removal of forms for :vertical surface such as retaing walls,partition walls (any thickness) including attached pilasters,Buttreses, plinth and string courses, fillets and the like. ( RMU foundation plinth)

20.38

9762

479

... More
Providing and laying in position (1:11/2:3) Reinforced cement conrete excluding the cost of centering, shuttering, finishing and reinfrocement (1 cement: 1½ coarse sand:3 graded stone agg 20mm nominal size) : ( RMU foundation plinth)All works upto plinth level

0.66

4737

7178

... More
In walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and structs etc. upto floor five level

2.66

21370

8034

... More
Providing TMT steel reinforcement bars of (SAIL, TATA. VIZAG, JSW Steel Ltd.) ) (Confirming to IS 1786 of 1986) for RCC work (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in all the floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member. ( RMU foundation plinth)

168.88

17732

105

... More
18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand) and top layer 6mm thick with cement plaster 1: 3 (1 cement : 3 coarse sand) finished with sponge. ( RMU foundation plinth)

15.18

4994

329

... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge. ( RMU foundation plinth)

4.66

1141

245

... More
S.A/L.A Clamps, Structural material & G.I. Nuts & Bolts

-

-

-

... More
Supply of HDGI X arm clamps for RCC Pole 11.00 mtr L.A, (Dimensions/specifications as per drawing no. CEE/E-711)

5

2070

414

... More
Supply of HDGI DP Structural material

274

46306

169

... More
G.I. Stay Set & Stay wire ( Rates should include excavation of pits for stay set i.e. G.I. Stay rod & plate (pit size of 600x600x900mm for LT and 11KV Stay sets)

-

-

-

... More
Supply of HDG.I. stay wire 7/10 SWG, The Stay wire shall comply with the specific requirements of IS: 2141-1979, IS: 4826-1979 & IS: 6594-1974 or the latest versions thereof.

20.2

2848

141

... More
Barbed wire, Danger Board & Earthing set

-

-

-

... More
Supply of HDG.I. barbed wire, Hot dip galvanized steel barbed wire type 4 conforming to IS: 278/1962 as amended up to date and galvanization conforming to IS: 4826/1979 as amended up to date

6

870

145

... More
Supply of Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete with brick masonary.

10

44280

4428

... More
Supply of Enamelled Danger board 440Volts/ 11000 Volts/ 3300 Volts:

2

496

248

... More
HDGI flat of size 25mm X 5mm for eathing.

80

9280

116

... More
FRP Fencing complete with Gate as per specification for Distribution Transformer (Size 4Mx3Mx2M)with concreting for FRP Fencing supports with plinth (0.3x0.3x0.5)Cu.m X 12 nos. Each ratio 1:3:6

1

76667

76667

... More
ACSR & AA Conductor

-

-

-

... More
Supply of ANT' conductor 7/3.10 mm nominal aluminium area 50mm² (190 amps max. at 40° C)

0.88

42315

48086

... More
Supply of GNAT' conductor 7/2.21 mm nominal aluminium area 25mm² (80 amps max. at 40° C)

0.99

25040

25293

... More
Erection Cost

-

-

-

... More
Distribution Transformers, Boxes (M.S),CCMS Panel, Lugs and LT Cables

-

-

-

... More
Erection of 100 KVA 11KV/0.4KV Distribution Transformers level II losses, Alluminium Winding, with Bimetallic Terminal Connectors, Energy Efficiency Level-II as per IS: 1180 (Part-I): 2014

1

11017

11017

... More
Erection of DTC Metering Unit

1

1072

1072

... More
Erection of Distribution Boxes (M.S) with 200Amps MCCB & Kit-Kat fuses (M. S. distribution box as per drawing No.CEE/E-689 Revision No.3 alongwith 12 nos. of 200A Kitkat Porcelain fuse carrier and base with extended terminals conforming in general to drawing No.EE-II/7/2002 with 1 no. moulded case circuit breaker (MCCB), 415V, AC, 50Hz with extended terminals conforming to IS 13947-2 as amended upto date)

1

4687

4687

... More
Erection of 150 sq.mm 3 and half Core XLPE unarmoured ,1.1KV grade cable

60

13320

222

... More
Erection of 185 sq.mm Single Core XLPE unarmoured ,1.1KV grade cable

60

10200

170

... More
Erection of 150 Sq.mm Compression Type Aluminium Tubular Terminal Ends(LUGS)(Aluminium crimping lugs shall confirm to IS:8309-1976 as amended upto date.)

16

1520

95

... More
Erection of 185 Sq.mm Compression Type Aluminium Tubular Terminal Ends(LUGS)(Aluminium crimping lugs shall confirm to IS:8309-1976 as amended upto date.)

8

760

95

... More
GOAB Switch, HG Fuse unit & Lightning Arrestor

-

-

-

... More
Erection of G.O.A.B. Switch 11 KV 200 Amps with operating pipe support of class B, 25mm dia., HDGI (12 KV rated voltage GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming to IS: 9921-Part1 to V as amended upto date and detailed specifications enclosed herewith. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufactures of the insulators and have minimum 320mm creepage distance and AB switches contacts shall be of copper/copper alloy.)

1

3971

3971

... More
Erection of H.G. Fuse unit 11 KV 200AMPS (Galvanising of all the materials used should be hot dipped Galvanised as per IS:2629/66, (Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas)

1

3368

3368

... More
Erection of Lightning/Surge Arrestors 9 KV, 5 KA Type: Gapless type Applicable standards: IEC 60099-4 & IS: 3070-1993 (part-3)

3

522

174

... More
A2XFY Aluminium Armoured XLPE UG HT Cable and CABLE JOINTING &TERMINATION KITS

-

-

-

... More
Supply, Erection, Testing and Comissioning of 3 core, 300 sq.mm. aluminium, XLPE insulated, armoured, 11KV Cable.

300

102600

342

... More
Supply, Erection, Testing and Comissioning of 3 core, 95sq.mm. aluminium, XLPE armoured, 11KV Cable.

22

4378

199

... More
Supply, Erection, Testing and Comissioning of Outdoor type, heat shrinkable, three phase, end termination kit complete, for 11KV XLPE cable of size 3 x 95sq.mm .

1

2648

2648

... More
Supply, Erection, Testing and Comissioning of Indoor type, heat shrinkable, three phase, end termination kit complete, for 11KV XLPE cable of size 3 x 95sq.mm .

1

2538

2538

... More
Supply, Erection, Testing and Comissioning of Indoor type, heat shrinkable, three phase, end termination kit complete, for 11KV XLPE cable of size 3 x 300sq.mm.

4

10192

2548

... More
Supply, Erection, Testing and Comissioning of heat shrinkable, three phase, straight through jointing kit complete, for 11KV XLPE cable of size 3 x 300sq.mm.

2

7426

3713

... More
RING MAIN UNITS & LOAD BREAK SWITCH UNITS

-

-

-

... More
Erection of 11KV, 630 Amps, Outdoor, SF6 Ring Main Unit with two Load Break Switches and one Circuit Breaker.

1

9720

9720

... More
Erection of 11KV, 630 Amps, Outdoor, SF6 Ring Main Unit with three Load Break Switches .

1

9720

9720

... More
Route Markers, Warning Tapes, RCC Hume pipe and GI PIPE

-

-

-

... More
Erection of RCC Cable route marker

3

768

256

... More
Design, Supply & Erection of Medium duty, HDGI Class B pipe of nominal diameter 100 mm (alongwith HDGI bends wherever required) for bridge crossing, riser pipe for 95Sq.mm & 300Sq.mm XLPE Cable etc., as per technical specifications including supporting arrangement for the pipe and 11 KV Bay.

15

1380

92

... More
Open Trenching method:- Excavation of pit, laying of protective covers, RCC hume pipe, earthing, foundations for equipments etc

-

-

-

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/ manual means in foundation pipeline trenches drain (not exceeding 1.5 mt in width or 10 sq.m on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m(a) for laying of HT/LT cables of various sizes in all kinds of soil, hard rock , providing barricading, danger lighting guarding etc. The trench lengths are as follows: a. All kinds of soil/rocks/laterite stone

32.4

15163

468

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/ manual means in foundation pipeline trenches drain (not exceeding 1.5 mt in width or 10 sq.m on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m(a) for laying of HT/LT cables of various sizes in all kinds of soil, hard rock , providing barricading, danger lighting guarding etc. The trench lengths are as follows: b. All type of ordinary rock including all types of laterite rock, blasting prohibited.

86.4

65923

763

... More
Filling of available excavated earth (excluding rock/stones) in trench in layer not exceeding 0.2mts. Depth, consolidating each deposited layer by ramming and watering lead up to 40mts.

93.9

11268

120

... More
Erection and laying of fine river sand of approved quality (except sandy soil) for cushioning of 11KV/LT underground cables.

13.4

-

-

... More
Providing and laying of PCC protective covers of size 0.4 mts long X 0.25 mts width and 50 mm thick, at non-road crossing & for partitioning Cable.

675

40500

60

-

-

-

... More
Erection of 11mtr long RCC Pole as per Drawing CEE/C-698

2

17200

8600

... More
Erection of 7.5mtr long RCC Pole as per Drawing CEE/C-837

25

92225

3689

... More
4 pin & 2 pin 'X' arm of channel

-

-

-

... More
Erection of HDGI 4 pin 'X' arm of ISMC 75 (75 x 40mm) M.S. Channel 1.1 mtr length, Cross arm not to be welded/joined at any place, Galvanising should be hot dipped (Dimensions/specifications as per drawing no: CEE/E/705).

27

7047

261

... More
Erection of HDGI 2 pin 'X' arm of ISMC 75 (75 x 40 mm) M.S. Channel 0.75 mtr length, Cross arm not to be welded/joined at any place, (Dimensions/specifications as per drawing no: CEE/E/704).

2

464

232

... More
S.A/L.A Clamps, Structural material & G.I. Nuts & Bolts

-

-

-

... More
Erection of HDGI 'X' arm clamps for RCC Pole 7.5 mtr S.A., (Dimensions/specifications as per drawing no. CEE/E-523)

6

192

32

... More
Erection of HDGI 'X' arm clamps for RCC Pole 7.5 mtr L.A. (Dimensions/specifications as per drawing no. CEE/E-523)

30

960

32

... More
Erection of HDGI X arm clamps for RCC Pole 11.00 mtr L.A, (Dimensions/specifications as per drawing no. CEE/E-711)

5

325

65

... More
Erection of HDGI DP Structural material

274

12878

47

... More
G.I. NUTS & BOLTS (Full thread and half thread, Hexagon nuts, Hexagon head bolt, hot-dip galvanised steel, as per IS 1363, the amount of zinc deposit over threaded portion of bolts, nuts, screws and washers shall be as per IS:1367, Galvanizing of steel components and accessories shall conform to IS:2629 and IS:2633. )G.I. Nuts & Bolts 100x16mm, 125x16mm, 150x16mm

75

2250

30

... More
Insulators & Metal Parts

-

-

-

... More
Erection of L.T. Shackle insulators: brown glazed shackle insulators of size 100mm x 115mm conforming to fig.No.4 and type 2 of IS: 1445/77 as amended upto date

37

3848

104

... More
Erection of Metal parts for L.T. Shackle insulators: G. I hardware suitable for L. T. shackle insulators of size 100 x 115 mm. conforming to type 2, fig. 4 of IS: 1445/77 as amended upto date

37

3848

104

... More
Erection of L.T. Pin Insulators, L. T. brown glazed porcelain pin insulators of size 100mm x 70mm conforming to type 1 fig 1 of IS:1445/1977 with amendment 2 of Feb.1981 (second revision) as amended upto date

54

5346

99

... More
Erection of G.I. Pin for L.T.Pin Insulators ,Forged G. I. Pin conforming to IS 7935/1975 as amended upto date suitable for L.T. porcelain pin insulator type 1 conforming to fig.1 of IS: 1445/77 with amendment

54

3996

74

... More
Erection of Break insulators 15 KV (88KN) Guy strain insulators of size 140 x 85mm. with minimum failing load of 88 KN and minimum creepage distance of 57 mm. confirming to fig 1 and designation ‘A’ of IS:5300/1969 as amended upto date.

6

648

108

... More
G.I. Stay Set & Stay wire ( Rates should include excavation of pits for stay set i.e. G.I. Stay rod & plate (pit size of 600x600x900mm for LT and 11KV Stay sets)

-

-

-

... More
Erection of G.I. Stay rod & plate LT/11KV line (as per drawing no. CEE/E-465 R)

6

10674

1779

... More
Erection of G.I. Turn Buckle with eye bolt 11 KV (as per drawing no. CEE/E-500)

6

1602

267

... More
Erection of HDG.I. stay wire 7/10 SWG, The Stay wire shall comply with the specific requirements of IS: 2141-1979, IS: 4826-1979 & IS: 6594-1974 or the latest versions thereof.

20.2

1252

62

... More
Erection of HDGI stay clamps for RCC Pole 11.00Mts L.A., (Dimensions/specifications as per drawing no. CEE/E-711)

2

196

98

... More
Erection of HDGI stay clamps for RCC Pole 7.5 mtr S.A., (Dimensions/specifications as per drawing no. CEE/E-523)

2

138

69

... More
Erection of HDGI stay clamps for RCC Pole 7.5 mtr L.A., (Dimensions/specifications as per drawing no. CEE/E-523)

2

138

69

... More
Barbed wire, Danger Board & Earthing set

-

-

-

... More
Erection of HDG.I. barbed wire, Hot dip galvanized steel barbed wire type 4 conforming to IS: 278/1962 as amended up to date and galvanization conforming to IS: 4826/1979 as amended up to date

6

276

46

... More
Erection of Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete with brick masonary.

10

26650

2665

... More
Erection of Enamelled Danger board 440Volts/ 11000 Volts/ 3300 Volts:

2

114

57

... More
Erection of HDGI flat of size 25mm X 5mm for eathing.

80

3840

48

... More
FRP Fencing complete with Gate as per specification for Distribution Transformer (Size 4Mx3Mx2M)with concreting for FRP Fencing supports with plinth (0.3x0.3x0.5)Cu.m X 12 nos. Each ratio 1:3:6

1

35000

35000

... More
ACSR & AA Conductor

-

-

-

... More
Erection of ACSR conductor 'WEASEL' 6 +1 / 2.59 mm nominal aluminium area 30mm² (139 amps max. at 45° C)

0.2

1422

7110

... More
Erection of ANT' conductor 7/3.10 mm nominal aluminium area 50mm² (190 amps max. at 40° C)

0.88

5837

6634

... More
Erection of GNAT' conductor 7/2.21 mm nominal aluminium area 25mm² (80 amps max. at 40° C)

0.99

6121

6183



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.