Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_ED_19567_1Bid Award Id
ViewTender No
Tender 17(24-25)/DIV-VI DT 23/1/2025Tender Authority
Electricity Department ViewPurchaser Address
-Website
http://eprocure.goa.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply and termination of indoor type end termination heat shrinkable kit for 11KV XLPE cable of size 3x300 sq.mm including sockets / lugs / connectors etc alongwith cable glands at 11KV Ring Main Unit & two way on load switch (DEOS). ( 3 for each DEOS & 2 for each RMU )
2
8840
17680
... More
Supply, erection, testing & commissioning of termination of indoor type end termination heat shrinkable kit for 11KV XLPE cable of size 95sqmm including sockets / lugs / connectors etc alongwith cable glands at 11KV Ring Main Unit.
2
6731
13462
... More
Supply and laying of precast RCC hume pipe of size 150 mm with required number of collars using cement mortar 1:2 for road crossing and at any other crossing as ordered.
20
807
16140
... More
RCC protective covers of size 600mm long x 250mm width and 50mm thick capable of bearing load of 135Kg. And covered with earth/ sand upto depth of 0.15mts. Confirming to IS 1255-1967 at non-road crossing. (as per CEE approved drawing, enclosed)
56
135
7560
... More
Supply and laying of river sand for cushioning of 11 KV XLPE cable.
3.3
2170
7161
... More
Bricks class design 75 kg/cm2 (1st class wire cut)
275
9
2612.5
... More
Supply and installing of cable route Makers (for entire route length)
5
528
2640
... More
HDG Strip 25mm x 5 mm for connecting earthing for RMU & DEOS ( 6 mts for each RMU )
48
116
5568
... More
Numbering of RMU/DEOS/distrbution box,
1
104
104.33
... More
Warning Tape
0.21
15000
3150
... More
Supply Erection and Comissioning of Distribution Boxes (M.S) with 400Amps MCCB & Kit-Kat fuses
1
63140
63140
... More
FRP Fencing complete with Gate as per specification for Distribution Transformer (Size 4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6
1
76667
76667
... More
Supply And Erection of AA CONDUCTOR ANT' conductor 7/3.10 mm nominal aluminium area 50mm² (190 amps max. at 40° C)
Hard drawn stranded all aluminium conductor conforming to IS: 398(Pt-I/96) as amended upto date of following sizes.Packing and marking of drum will be as per IS:Materials shall be supplied on non-returnable wooden drums.Acceptance tests and routine tests shall be carried out at manufacturers works and test reports shall be furnished before supply of materials.The Department reserves right to witness all the above tests.
0.88
48086
42315.68
... More
Supply And Erection of AA CONDUCTOR GNAT' conductor 7/2.21 mm nominal aluminium area 25mm² (80 amps max. at 40° C) Hard drawn stranded all aluminium conductor conforming to IS: 398(Pt-I/96) as amended upto date of following sizes.Packing and marking of drum will be as per IS:Materials shall be supplied on non-returnable wooden drums.Acceptance tests and routine tests shall be carried out at manufacturers works and test reports shall be furnished before supply of materials.The Department reserves right to witness all the above tests.
0.32
25293
8093.76
... More
COST OF ERECTION
-
-
-
... More
Supply, laying, Testing and Comissioning of 11KV , 3 core 300 sq.mm. A2XFY Al. armoured XLPE cable through conventional open trenching method in any type of soil including hard laterite.
55
342
18810
... More
Supply, Erection, Testing & commissioning of 3 core, 95 sq.mm Aluminium, XLPE insulated armoured, 11KV (earthed neutral) Cable for connecting to the distribution transformer centres and 11 KV HT installations and any other equipments. (from RMU to Transformer / HT Consumers)
15
199
2985
... More
Supply, erection, testing & commissioning of 3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 1CB
Extensible/Non Extensible Two (2) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 and One (1) vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU, Current Transformer and Numerical Relay with communication in all CB module. Suitable arrangement for mounting FRTU , modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.with fault passage indicator other accessories.
1
9720
9720
... More
Supply, erection, testing & commissioning of XLPE heat shrinkable straight through jointing kit for 300 sq.mm, 3 core, 11KV XLPE cable.
2
3713
7426
... More
Supply and termination of indoor type end termination heat shrinkable kit for 11KV XLPE cable of size 3x300 sq.mm including sockets / lugs / connectors etc alongwith cable glands at 11KV Ring Main Unit & two way on load switch (DEOS). ( 3 for each DEOS & 2 for each RMU )
2
2548
5096
... More
Supply, erection, testing & commissioning of termination of indoor type end termination heat shrinkable kit for 11KV XLPE cable of size 95sqmm including sockets / lugs / connectors etc alongwith cable glands at 11KV Ring Main Unit.
2
2538
5076
... More
Excavation of trench of size 1.10 x 0.45 x (1 Run ) Mts + 1.1 x 0.6x( 2Run) for laying of 1 runs of HT cable under ground which includes digging in Hard Rock, opening of road etc.
a) All kinds of soil
4.95
468
2316.6
... More
b) All types of Ordinary rock including all types of laterite rock, blasting prohibited
13.2
763
10071.6
... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge.
13.2
120
1584
... More
Supply and laying of precast RCC hume pipe of size 150 mm with required number of collars using cement mortar 1:2 for road crossing and at any other crossing as ordered.
20
254
5080
... More
RCC protective covers of size 600mm long x 250mm width and 50mm thick capable of bearing load of 135Kg. And covered with earth/ sand upto depth of 0.15mts. Confirming to IS 1255-1967 at non-road crossing. (as per CEE approved drawing, enclosed)
56
60
3360
... More
Supply and installing of cable route Makers (for entire route length)
5
256
1280
... More
Supply and erection of earthing with 40mm dia x 2.5 mts long class 'B' GI pipe, with charcoal, salt, inserted in pit excavated of size not less than 500mm x 500mm x 2400mm as per Drg No. CEE/E-829( 2 for each RMU & DEOS).
8
2665
21320
... More
HDG Strip 25mm x 5 mm for connecting earthing for RMU & DEOS ( 6 mts for each RMU )
48
48
2304
... More
Supply, erection, testing and commissioning of 200 KVA, 11/0.433 KV Delta Star, Alluminium wound, oil colled outdoor type Distribution transformer including terminal boxes at both LV and HV Sides.
1
15638
15638
... More
Supply Erection and Comissioning of Distribution Boxes (M.S) with 400Amps MCCB & Kit-Kat fuses
1
8795
8795
... More
Supply & laying of unarmoured 1 core 300 sq.mm XLPE power cable to be laid from transformer to LV panel (7 run)
84
218
18312
... More
FRP Fencing complete with Gate as per specification for Distribution Transformer (Size 4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6
1
35000
35000
... More
Supply And Erection of RCC poles 9.00 mtr long as per Drawing CEE/C-836
3
5900
17700
... More
Supply And Erection of HDGI 2 pin 'X' arm of ISMC 75 (75 x 40 mm) M.S. Channel 0.75 mtr length, Cross arm not to be welded/joined at any place, (Dimensions/specifications as per drawing no: CEE/E/704).
7
232
1624
... More
Supply And Erection of HDGI 4 pin 'X' arm of ISMC 75 (75 x 40 mm) M.S. Channel 0.75 mtr length, Cross arm not to be welded/joined at any place, (Dimensions/specifications as per drawing no: CEE/E/704).
11
261
2871
... More
Supply And Erection of HDGI 'X' arm clamps for RCC Pole 9.00 mtr S.A. (Dimensions/specifications as per drawing no. CEE/E-524)
18
45
810
... More
Supply and Erection of L.T. Pin Insulators
L. T. brown glazed porcelain pin insulators of size 100mm x 70mm conforming to type 1 fig 1 of IS:1445/1977 with amendment 2 of Feb.1981 (second revision) as amended upto date. Minimum failing load shall be 3.5kN.Insulators shall have marking and packing as prescribed in IS. Acceptance tests and routine tests shall be carried out as per IS at manufacturers works and test results shall be furnished by the manufacturer before supply of materials.
20
99
1980
... More
Supply and Erection of G.I. Pin for L.T.Pin Insulators
Forged G. I. Pin conforming to IS 7935/1975 as amended upto date suitable for L.T. porcelain pin insulator type 1 conforming to fig.1 of IS: 1445/77 with amendment No. 2, Feb.1981, of size 100 x 70 mm. G. I. pin shall comprise of G. I. nut and spring washer and conform to fig. No. 2 of IS: 7935/1975. Minimum failing load of pin shall be 3.5 KN. The fitting shall be marked with the manufacturer’s name or trade mark as per IS. The packing shall be as per IS.
G. I. pins and nuts shall be hot dip galvanized as per IS: 2629/66 as amended up to date. The washers shall be electro galvanized.
Acceptance tests and Routine tests shall be carried out at the manufacturers works and test reports shall be furnished before supply of materials.
20
74
1480
... More
Supply and Erection of L.T. Shackle insulators:
brown glazed shackle insulators of size 100mm x 115mm conforming to fig.No.4 and type 2 of IS: 1445/77 as amended upto date. Minimum failing load shall be 16kN.Insulators shall have marking and packing as prescribed in IS. Acceptance tests and routine tests shall be carried out as per IS at manufacturers works and test results shall be furnished by the manufacturer before supply of materials.
90
104
9360
... More
Supply and Erection of Metal parts for L.T. Shackle insulators:
G. I hardware suitable for L. T. shackle insulators of size 100 x 115 mm. conforming to type 2, fig. 4 of IS: 1445/77 as amended upto date. Hardware or fitting shall conform to fig. 4 of IS 7935-1975 as amended up to date, comprise of 2 G. I. strips, 2 G. I. bolts and 2 nuts with spring washers.
All metal parts including nut bolts should be hot dip galvanized as per IS: 2629/66 as amended up to date. Spring washers shall be electro galvanized, (Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas.
Acceptance tests and routine tests shall be carried out as per IS and test results shall be furnished by the manufacturer before supply of materials.
Department reserves the right to witness all the above tests.
90
104
9360
... More
Supply And Erection of AA CONDUCTOR ANT' conductor 7/3.10 mm nominal aluminium area 50mm² (190 amps max. at 40° C)
Hard drawn stranded all aluminium conductor conforming to IS: 398(Pt-I/96) as amended upto date of following sizes.Packing and marking of drum will be as per IS:Materials shall be supplied on non-returnable wooden drums.Acceptance tests and routine tests shall be carried out at manufacturers works and test reports shall be furnished before supply of materials.The Department reserves right to witness all the above tests.
0.88
10300
9064
... More
Supply And Erection of AA CONDUCTOR GNAT' conductor 7/2.21 mm nominal aluminium area 25mm² (80 amps max. at 40° C) Hard drawn stranded all aluminium conductor conforming to IS: 398(Pt-I/96) as amended upto date of following sizes.Packing and marking of drum will be as per IS:Materials shall be supplied on non-returnable wooden drums.Acceptance tests and routine tests shall be carried out at manufacturers works and test reports shall be furnished before supply of materials.The Department reserves right to witness all the above tests.
0.32
9100
2912
... More
CIVIL PART
-
-
-
... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on pian) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in
-
-
-
... More
All Kinds of soil
2.02
286
576.58
... More
All types of Ordinary rock including all types of laterite rock, blasting prohibited
1.34
639
858.82
... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge.
1.18
245
289.1
... More
Brick work using common burnt building bricks in cement mortar 1:3 (1 cement : 3 coarse sand) with bricks of class designation 40 kg/cm2(wire cut bricks)
-
-
-
... More
In fondation and plinth
1.88
7521
14139.48
... More
Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in piprline trenches and other foundations complete
0.47
2211
1039.17
... More
Providing & laying cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded granitic or basaltic stone aggrt. 20 mm. nominal size) excluding cost of centering, shuttering and finishing
-
-
-
... More
All works upto plinth level
0.47
6325
2972.75
... More
Providing & laying cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded granitic or basaltic stone aggrt. 20 mm. nominal size) excluding cost of centering, shuttering and finishing
-
-
-
... More
All works upto plinth level
1.54
6810
10487.4
... More
Centering & shuttering including strutting, Propping & removal of forms for:
-
-
-
... More
Foundations, Footings, Bases for columns
9
407
3663
... More
12mm cement plaster 1:4 (1 cement : 4 fine sand)
6.82
223
1520.86
... More
Transportation & carriage of material
-
-
-
... More
Earth upto 10km
1.68
121
203.78
... More
Supplying & spreading of 40/20mm basaltic or granitic stone aggregate in the switchyard.
1.47
2217
3258.99