Electricity Department Tender

View complete overview of Goa Electricity Department Tender

Electricity Department Tender

Works
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date7 Mar 2024
Closing Date11 Apr 2024
Tender Amount₹ 27,03,945 
Notes
Download

Costs

  • EMD

    ₹ 54,079
  • Document Cost

    ₹ 1,500
  • Tender Fee

    ₹ 5,408

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of HDGI nuts & bolts.G.I. Hexagonal head bolts and hexagonal nuts conforming to IS 1363 part 1 to 3 1992 as amended upto date.The bolts and nuts shall be hot dip galvanized as per IS: 2629-1985 as amended upto date

54

12312

228

... More
Supply of Cement concrete 1:2:4(1 cement: 2 Sand, 4 graded granite/basaltic, aggregate 20mm nominal size) including cost of centering, shuttering & muffing 0.4mts above the ground & properly curved.

6.48

35996

5555

... More
Supply of Enamelled Danger boards for 11 KV of size 250mm x 200mm

12

2976

248

... More
Supply of Anticlimbing device(barbed wire).Hot dip galvanized steel barbed wire type 4 conforming to IS:278/1962 as amended upto date and galvanization conforming to IS:4826/1979as amended upto date

12

1740

145

... More
Supply of HDGI Structure Materials. shall be hot dipped galvanized

1644

277836

169

... More
Supply of LA stay clamps for 9mt RCC pole.All clamps & suitable nut bolts shall be hot dipped galvanized generally conforming to IS - 2633/72

60

29460

491

... More
Supply of LA X arm clamps for 9mt RCC pole.All clamps & suitable nut bolts shall be hot dipped galvanized generally conforming to IS - 2633/72

72

19152

266

... More
Supply of SA X arm clamps for 9mt RCC pole.All clamps & suitable nut bolts shall be hot dipped galvanized generally conforming to IS - 2633/72

12

3192

266

... More
Supply of Guard cross arm 1.5 mtr long.Cross arms shall be made of HDGI channel of size ISMC 75X40. hot dip galvanizing generally conforming to IS – 2633/72 . The cross arm shall not be welded/joined at any place except as specified

12

26352

2196

... More
Supply of 11 KV GOAB switch with 200 A.12 KV rated voltage GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming to IS: 9921-Part1 to V as amended upto date and detailed specifications enclosed herewith. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufactures of the insulators and have minimum 320mm creepage distance and AB switches contacts shall be of copper/copper alloy

6

141210

23535

... More
Supply of Earthing complete with 2.5mts long, 40mm GI earthing pipe, class B, 20kgs each of salt and charcoal, excvation, re-filling etc.Earthing pipe made of Hot Dip galvanized steel tube of heavy class, 40mm nominal bore conforming to IS 1239 Part 1 1990 as amended upto date and Hot Dip zinc coating shall conform to IS 4736-1968 as amended upto date

30

132840

4428

... More
Supply of 11 KV Disc Insulators 70KN with H.D.G.I. Metal parts.11 KV disc insulators ball and socket type, type ‘A’ porcelain brown glazed duly cemented at factory with MCI socket cap, forged steel ball pin and supplied with Phosphor bronze “W” split pin as per IS 731-1971 as amended upto date. Pin ball diameter 16 mm. Minimum Creepage distance 320 mm. Ferrous parts shall be galvanized as per relevant IS

36

103896

2886

... More
Supply of 11 KV Pin Insulator with H.D.G.I. Pin 11 KV brown glazed porcelain pin insulator with minimum failing load of 5 KN and the Minimum creepage distance of 320 mm conforming to IS 731-1971 as amended upto date.Insulators shall be marked and packed as per IS

18

12474

693

... More
Supply of ACSR 'WEASEL' of size ( 6/1/2.59mm) for line,earthing and jumpering .Packing and marking of drum will be as per IS:Conductor length shall be 1500 mtr. with tolerance of +/- 5%

0.75

25056

33409

... More
Supply of 11 KV HG fuse,200A, Horn gap type fuse I.TECHNICAL PARTICULARS: 1. Highest System voltage : 12 KV (R.M.S) 2. Impulse voltage withstand voltage : 75 KV (Peak) 3. One minute power frequency withstand voltage : 35 KV (R.M.S.) 4. Continuous current rating of the unit : 200 Amps

6

62700

10450

... More
Supplyof 9 KV, 5A Lightning Arrestor, pole mounted.9 KV, 5 KA nominal discharge current Metal Oxide gapless distribution class lightning arrestor conforming to IEC-60099-4 and IS 3070 Part 3 1993 as amended upto date suitable for 11 KV 50 HZ effectively earthed neutral system with necessary mounting arrangements and connector suitable to connect ACSR conductor upto overall diameter 12.30 mm.The marking of the Lightning Arrestors shall be as per IS

18

54594

3033

... More
Supply of MS Distribution box complete.M. S. distribution box MCCB of 400 Amps capacity Kit Kat Porcelain fuse carrier and base with extended terminals.

6

378840

63140

... More
Supply of XLPE unarmoured cable 1 core 90 sq.mm.The unarmoured cable shall be of 1 core and of sizes as required i.e.90Sq.mm that shall be suitably terminated at both the ends with appropriate sizes of Aluminum lugs duly crimped using a crimping tool. Appropriate sizes of G.I / Brass nut / bolts / washers shall be used for firmly connecting the same to the MCCB’s/Transformer L.T. Bushings/Outgoing LT feeder

192

24576

128

... More
Supply of XLPE unarmoured cable 1 core 120 sq.mm.The unarmoured cable shall be of 1core and of sizes as required i.e.120 Sq.mm that shall be suitably terminated at both the ends with appropriate sizes of Aluminum lugs duly crimped using a crimping tool. Appropriate sizes of G.I / Brass nut / bolts / washers shall be used for firmly connecting the same to the MCCB’s/Transformer L.T. Bushings/Outgoing LT feeder

96

15744

164

... More
Supply of XLPE unarmoured cable 1 core 185 sq.mm.The unarmoured cable shall be of 1core and of sizes as required i.e.185 Sq.mm that shall be suitably terminated at both the ends with appropriate sizes of Aluminum lugs duly crimped using a crimping tool. Appropriate sizes of G.I / Brass nut / bolts / washers shall be used for firmly connecting the same to the MCCB’s/Transformer L.T. Bushings/Outgoing LT feeder

528

129360

245

... More
Supply of XLPE unarmoured cable 1 core 240 sq.mm.The unarmoured cable shall be of 1core and of sizes as required i.e.240 Sq.mm that shall be suitably terminated at both the ends with appropriate sizes of Aluminum lugs duly crimped using a crimping tool. Appropriate sizes of G.I / Brass nut / bolts / washers shall be used for firmly connecting the same to the MCCB’s/Transformer L.T. Bushings/Outgoing LT feeder

192

70272

366

... More
Supply of Aluminum crimping lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade 1E of IS 5082-1969 suitable for aluminium cables of following sizes: 1)240Sq.mm

16

1504

94

... More
Supply of Aluminum crimping lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade 1E of IS 5082-1969 suitable for aluminium cables of following sizes: 1. 185Sq.mm.

44

3432

78

... More
Supply of Aluminum crimping lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade 1E of IS 5082-1969 suitable for aluminium cables of following sizes: 1. 120Sq.mm.

16

864

54

... More
Supply of Aluminum crimping lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade 1E of IS 5082-1969 suitable for aluminium cables of following sizes: 1. 90Sq.mm.

16

640

40

... More
Supply of Aluminum crimping lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade 1E of IS 5082-1969 suitable for aluminium cables of following sizes: 1. 70Sq.mm.

60

2040

34

... More
Supply of Cross Arm Channel 4Pin .The cross arms shall be made of M.S. channel of ISMC-75 vide table 2 of IS: 8081 1964 . The cross arms shall be without any joints. The cross arms shall be hot dipped galvanized generally conforming to IS - 2633/72. The length of the 4pin cross arm shall be 1110mm with 4 holes of 22 dia each on each flange section. In addition 2 holes of size 18mm x 40mm slotted holes shall be provided on the cross arm for clamping arrangement to the pole. The length of the 4pin side cross arm shall be 1410mm with 4 holes of 22 dia each on each flange section. In addition 2 holes of size 18mm x 40mm slotted holes shall be provided on the cross arm 40 mm from the left edge of the X-arm for clamping arrangement to the pole & two holes of size 17mm dia at 355mm & 660mm from the slotted hole for arrangement to fix angle support. The angle support shall be of ISA 50x50x6mm G.I. with 17 mm dia holes at the two ends. The other end of the angle shall be clamps utilizing suitable G. I. stay clamps of length 312mm end to end

15

16635

1109

... More
Supply of Cross Arm Channel 2Pin .The cross arms shall be made of M.S. channel of ISMC-75 vide table 2 of IS: 8081 1964 . The cross arms shall be without any joints. The cross arms shall be hot dipped galvanized generally conforming to IS - 2633/72. The length of the 4pin cross arm shall be 1110mm with 4 holes of 22 dia each on each flange section. In addition 2 holes of size 18mm x 40mm slotted holes shall be provided on the cross arm for clamping arrangement to the pole. The length of the 4pin side cross arm shall be 1410mm with 4 holes of 22 dia each on each flange section. In addition 2 holes of size 18mm x 40mm slotted holes shall be provided on the cross arm 40 mm from the left edge of the X-arm for clamping arrangement to the pole & two holes of size 17mm dia at 355mm & 660mm from the slotted hole for arrangement to fix angle support. The angle support shall be of ISA 50x50x6mm G.I. with 17 mm dia holes at the two ends. The other end of the angle shall be clamps utilizing suitable G. I. stay clamps of length 312mm end to end

15

8535

569

... More
Supply of Insulator -(LT) Shackle .L.T. brown glazed shackle insulators of size 100mm x 115mm conforming to fig.No.4 and type 2 of IS: 1445/77 as amended upto date. Minimum failing load shall be 16kN. Insulators shall have marking and packing as prescribed in IS

90

33480

372

... More
Erection Cost

-

-

-

... More
Erection of 9 mts. long RCC poles .The poles should be as per drawing approved by CEE and conforming to IS standards as amended upto date. The Component used for pole shall conform to following IS amended upto date.

12

52896

4408

... More
Erection of Stay set complete for 9.0 mts RCC Pole.HDGI Stay Sets Complete Comprising of stay rod with plate, HDGI stay wire of size 7/10swg, Break insulator of 15KV/8KV,HDGI turn buckle with eye bolt, suitable HDGI stay clamps, HDGI nut bolts, conforming to drawings approved. The Stay wire shall comply with the specific requirements of IS: 2141-1979, IS: 4826-1979 & IS: 6594-1974 or the latest versions thereof and also as per the specifications enclosed.

12

29448

2454

... More
Providing of HDGI nuts & bolts.G.I. Hexagonal head bolts and hexagonal nuts conforming to IS 1363 part 1 to 3 1992 as amended upto date.The bolts and nuts shall be hot dip galvanized as per IS: 2629-1985 as amended upto date

54

1620

30

... More
Fixing of Enamelled danger board of size 250mm x 200mm

12

684

57

... More
Fixing of Anticlimbing device(barbed wire).Hot dip galvanized steel barbed wire type 4 conforming to IS:278/1962 as amended upto date and galvanization conforming to IS:4826/1979as amended upto date

12

2100

175

... More
Providing of HDGI Structure Materials. shall be hot dipped galvanized

1644

77268

47

... More
Fixing of LA stay clamps for 9mt RCC pole.shall be hot dipped galvanized generally conforming to IS - 2633/72

60

4740

79

... More
Fixing of GI Xarm clamp LA for 9.0mts pole.shall be hot dipped galvanized generally conforming to IS - 2633/72

72

3240

45

... More
Fixing of GI Xarm clamp SA for 9.0mts pole.shall be hot dipped galvanized generally conforming to IS - 2633/73

12

540

45

... More
Fixing of Guard cross arm 1.5 mtr long.Cross arms shall be made of HDGI channel of size ISMC 75X40. hot dip galvanizing generally conforming to IS – 2633/72 . The cross arm shall not be welded/joined at any place except as specified

12

6552

546

... More
Erection of 11 KV GOAB switch with 200 A.12 KV rated voltage GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming to IS: 9921-Part1 to V as amended upto date and detailed specifications enclosed herewith. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufactures of the insulators and have minimum 320mm creepage distance and AB switches contacts shall be of copper/copper alloy

6

23826

3971

... More
ErectionEarthing complete with 2.5mts long, 40mm GI earthing pipe, class B, 20kgs each of salt and charcoal, excvation, re-filling etc.Earthing pipe made of Hot Dip galvanized steel tube of heavy class, 40mm nominal bore conforming to IS 1239 Part 1 1990 as amended upto date and Hot Dip zinc coating shall conform to IS 4736-1968 as amended upto date

30

79950

2665

... More
Fixing of 11 KV Disc Insulators 45KN with H.D.G.I. Metal parts.11 KV disc insulators ball and socket type, type ‘A’ porcelain brown glazed duly cemented at factory with MCI socket cap, forged steel ball pin and supplied with Phosphor bronze “W” split pin as per IS 731-1971 as amended upto date. Pin ball diameter 16 mm. Minimum Creepage distance 320 mm. Ferrous parts shall be galvanized as per relevant IS

36

13500

375

... More
Fixing of 11 KV Pin Insulator with H.D.G.I. Pin 11 KV brown glazed porcelain pin insulator with minimum failing load of 5 KN and the Minimum creepage distance of 320 mm conforming to IS 731-1971 as amended upto date.Insulators shall be marked and packed as per IS

18

2736

152

... More
Stringing of ACSR 'WEASEL' of size ( 6/1/2.59mm) for line, earthing and jumpering .Packing and marking of drum will be as per IS:Conductor length shall be 1500 mtr. with tolerance of +/- 5%

0.75

5332

7110

... More
Fixing of 11 KV HG fuse,200A, Horn gap type fuse I.TECHNICAL PARTICULARS: 1. Highest System voltage : 12 KV (R.M.S) 2. Impulse voltage withstand voltage : 75 KV (Peak) 3. One minute power frequency withstand voltage : 35 KV (R.M.S.) 4. Continuous current rating of the unit : 200 Amps

6

20208

3368

... More
Erection of 9 KV, 5A Lightning Arrestor, pole mounted.9 KV, 5 KA nominal discharge current Metal Oxide gapless distribution class lightning arrestor conforming to IEC-60099-4 and IS 3070 Part 3 1993 as amended upto date suitable for 11 KV 50 HZ effectively earthed neutral system with necessary mounting arrangements and connector suitable to connect ACSR conductor upto overall diameter 12.30 mm.The marking of the Lightning Arrestors shall be as per IS

18

3132

174

... More
Erection of MS Distribution box complete.M. S. distribution box MCCB of 400 Amps capacity Kit Kat Porcelain fuse carrier and base with extended terminals.

6

52770

8795

... More
Removing & Re-erection of Distribution transformer metering unit

6

9648

1608

... More
Erection of XLPE unarmoured cable 1 core 90 sq.mm.The unarmoured cable shall be of 1 core and of sizes as required i.e.90Sq.mm that shall be suitably terminated at both the ends with appropriate sizes of Aluminum lugs duly crimped using a crimping tool. Appropriate sizes of G.I / Brass nut / bolts / washers shall be used for firmly connecting the same to the MCCB’s/Transformer L.T. Bushings/Outgoing LT feeder

192

17472

91

... More
Erection of XLPE unarmoured cable 1 core 120 sq.mm.The unarmoured cable shall be of 1core and of sizes as required i.e.120 Sq.mm that shall be suitably terminated at both the ends with appropriate sizes of Aluminum lugs duly crimped using a crimping tool. Appropriate sizes of G.I / Brass nut / bolts / washers shall be used for firmly connecting the same to the MCCB’s/Transformer L.T. Bushings/Outgoing LT feeder

96

9120

95

... More
Erection of XLPE unarmoured cable 1 core 185 sq.mm.The unarmoured cable shall be of 1core and of sizes as required i.e.185 Sq.mm that shall be suitably terminated at both the ends with appropriate sizes of Aluminum lugs duly crimped using a crimping tool. Appropriate sizes of G.I / Brass nut / bolts / washers shall be used for firmly connecting the same to the MCCB’s/Transformer L.T. Bushings/Outgoing LT feeder

528

89760

170

... More
Erection of XLPE unarmoured cable 1 core 240 sq.mm.The unarmoured cable shall be of 1core and of sizes as required i.e.240 Sq.mm that shall be suitably terminated at both the ends with appropriate sizes of Aluminum lugs duly crimped using a crimping tool. Appropriate sizes of G.I / Brass nut / bolts / washers shall be used for firmly connecting the same to the MCCB’s/Transformer L.T. Bushings/Outgoing LT feeder

192

38400

200

... More
Removing and reerection of existing 200 KVA, Distribution transformer

2

46914

23457

... More
Removing and reerection of existing 100 KVA, Distribution transformer

4

66102

16525.5

... More
Providing of Aluminum crimping lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade 1E of IS 5082-1969 suitable for aluminium cables of following sizes: 1)240Sq.mm

16

1616

101

... More
Providing of Aluminum crimping lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade 1E of IS 5082-1969 suitable for aluminium cables of following sizes: 1. 180 Sq.mm.

44

4180

95

... More
Providing of Aluminum crimping lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade 1E of IS 5082-1969 suitable for aluminium cables of following sizes: 1. 120Sq.mm.

16

1408

88

... More
Providing of Aluminum crimping lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade 1E of IS 5082-1969 suitable for aluminium cables of following sizes: 1. 90Sq.mm.

16

1040

65

... More
Providing of Aluminum crimping lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade 1E of IS 5082-1969 suitable for aluminium cables of following sizes: 1. 70Sq.mm.

60

3540

59

... More
Removing & re-stringing of ACSR 'WEASEL' of size ( 6/1/2.59mm) .Packing and marking of drum will be as per IS:Conductor length shall be 1500 mtr. with tolerance of +/- 5%

0.84

8958

10665

... More
Removing & restringing of AA ANT conductor

0.72

7164

9951

... More
Removing & restringing of AA GNAT conductor

0.72

6677

9274

... More
Fixing of Cross Arm Channel 4Pin .The cross arms shall be made of M.S. channel of ISMC-75 vide table 2 of IS: 8081 1964 . The cross arms shall be without any joints. The cross arms shall be hot dipped galvanized generally conforming to IS - 2633/72. The length of the 4pin cross arm shall be 1110mm with 4 holes of 22 dia each on each flange section. In addition 2 holes of size 18mm x 40mm slotted holes shall be provided on the cross arm for clamping arrangement to the pole. The length of the 4pin side cross arm shall be 1410mm with 4 holes of 22 dia each on each flange section. In addition 2 holes of size 18mm x 40mm slotted holes shall be provided on the cross arm 40 mm from the left edge of the X-arm for clamping arrangement to the pole & two holes of size 17mm dia at 355mm & 660mm from the slotted hole for arrangement to fix angle support. The angle support shall be of ISA 50x50x6mm G.I. with 17 mm dia holes at the two ends. The other end of the angle shall be clamps utilizing suitable G. I. stay clamps of length 312mm end to end

15

3915

261

... More
Fixing of Cross Arm Channel 2Pin .The cross arms shall be made of M.S. channel of ISMC-75 vide table 2 of IS: 8081 1964 . The cross arms shall be without any joints. The cross arms shall be hot dipped galvanized generally conforming to IS - 2633/72. The length of the 4pin cross arm shall be 1110mm with 4 holes of 22 dia each on each flange section. In addition 2 holes of size 18mm x 40mm slotted holes shall be provided on the cross arm for clamping arrangement to the pole. The length of the 4pin side cross arm shall be 1410mm with 4 holes of 22 dia each on each flange section. In addition 2 holes of size 18mm x 40mm slotted holes shall be provided on the cross arm 40 mm from the left edge of the X-arm for clamping arrangement to the pole & two holes of size 17mm dia at 355mm & 660mm from the slotted hole for arrangement to fix angle support. The angle support shall be of ISA 50x50x6mm G.I. with 17 mm dia holes at the two ends. The other end of the angle shall be clamps utilizing suitable G. I. stay clamps of length 312mm end to end

15

3480

232

... More
Fixing of Insulator -(LT) Shackle .L.T. brown glazed shackle insulators of size 100mm x 115mm conforming to fig.No.4 and type 2 of IS: 1445/77 as amended upto date. Minimum failing load shall be 16kN. Insulators shall have marking and packing as prescribed in IS

90

18720

208

... More
Removing of MS Distribution Box complete 400Amps with Kit kat fuse

6

26385

4397.5

... More
Removing of HDGI Structure Materials

1380

32430

23.5

... More
Removing of 11 KV GOAB switch 200A

6

11913

1985.5

... More
Removing 11 KV HG fuse set 200A

6

10104

1684

... More
Removing of 11kv Disc insulators with metal parts 70KN

36

6750

187.5

... More
Removing of Rail poles 11 mtr long

6

63150

10525

... More
Removing of RCC poles 9 mtr long

6

13224

2204

... More
Removing of 4 pin cross arm with clamp

15

1957

130.5

... More
Removing of 2 pin cross arm with clamp

15

1740

116

... More
Removing of LT Shackle insulator with metal parts

90

9360

104

... More
Removing of LT pin insulators with GI pin

18

1368

76

... More
Removing XLPE armoured cable 3 1/2 core 95sq.mm.

48

3576

74.5

... More
Removing XLPE armoured cable 31/2 core 120sq.mm.

24

2112

88

... More
Removing XLPE armoured cable 3 1/2 core 185sq.mm.

132

15048

114

... More
Removing XLPE armoured cable 31/2 core 240sq.mm.

48

6528

136



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.