Electricity Department Tender

View complete overview of Goa Electricity Department Tender

Electricity Department Tender

Works
Civil And Construction
Electrical Generators And Transformers
Building Construction
Electrical and Electronics
Electrical Works
Eprocure
Opening Date4 Oct 2024
Closing Date14 Oct 2024
Tender Amount₹ 63,04,020 
Notes
Download

Costs

  • EMD

    ₹ 1,26,080
  • Document Cost

    ₹ 1,000
  • Tender Fee

    ₹ 6,000

Summary

Work Of Renovation Of 11 Nos Of Dtc Under The Jurisdiction Of So Korgao Under Sub Div I Pernem Div Xvii Mapusa

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Stay set complete along with Stay rod with plate, Turnbuckle with eye bolt 11KV, Stay wire 7/10SWG, Break insulator, 8KV, Stay clamps, GI Nuts & Bolts 65 x 16 mm for 11.0 mtr RCC pole

22

4613

101498.54

... More
HDGI Structure Material

2860

169

483340

... More
11 KV GOAB 200 amps 3 pole with operating pipe support of class B, 25 mm dia.

11

23535

258885

... More
11KV, 200A Horn gap fuse unit (set of three)

11

10450

114950

... More
9KV, 5KA Lightning Arreastor pole mounted

33

3033

100089

... More
Earthing complete with 40 mm GI pipe, 2.5 mtrs long along with 20 kgs each salt, charcoal complete

68

2730

185640

... More
MS Distribution box with MCCB 200 amps has bar made out of aluminium strips 40x10mm Other accessories, 3Ph energy meter, suitable CT's of 200/5 amps & MCCB 100A for 4 feeder arrangement of 100KVA distribution T/C

1

48387

48387

... More
MS Distribution box with MCCB 400 amps has bar made out of aluminium strips 40x10mm Other accessories, 3Ph energy meter, suitable CT's of 200/5 amps & MCCB 100A for 4 feeder arrangement of 100KVA distribution T/C

1

63140

63140

... More
300/5 LT CT ring type,measuring CT coil of rating300/5A,Class I accuracy, 50Hz, 660V, Burden:15VA conferming to IS2705/1992 as amended up to date 3ph, 4W, Electronic Trivector Meter,LT CT operated 3X240v /5A,50Hz,class 0.5s,Category a9forDTC) with Rs232 and Optical port and compliance to BIS ICs Doc: ETD 13(6211) april,2010.Polemounted MS Box(outdoor type )Electronic Meter as per Drawing No. EE/VIII/64(REV).1.1KV Multistrand copperconductor ,XLPE insulated,armoured control cable conferming to relevent IS amended up to date and of size 4 core x 2.5sq,mm.High grade 3/4" brass gland for 4 core 2.5sqmm. cable

4

25688

102752

... More
XLPE single core unarmoured 240 sq mm 1.1kv grade

384

366

140544

... More
XLPE Single Core unarmoured, 1.1 KV grade cable 185 sq.mm.

528

245

129360

... More
XLPE Single Core unarmoured 150 sq mm 1.1 KV grade

240

201

48240

... More
XLPE single core unarmoured 120 sq mm 1.1kv grade

624

164

102336

... More
XLPE Single Core unarmoured 50 sq mm 1.1 KV grade

550

83

45650

... More
HDG cut point channel of ISMC 75x40x7.3mm 1.3 mtrs long with HDG clamps & HDG nut bolts etc for 11 mts long RCC pole

2

2464

4928.4

... More
11 KV Disc insulator 45 KN with HDGI metal parts

27

2365

63855

... More
ACSR Weasel Conductor 6/1/2.59 (nominal aluminium area 30 mm2) (139 amp max at 450C)

0.55

33409

18374.95

... More
Enamelled Danger Boards 440 Volts

22

248

5456

... More
Anticlimbing device

22

962

21164

... More
HDG LT 4 pin cross arm channel type HDG clamps & HDG nut bolts etc for 11.0 mts long RCC pole

21

1614

33898.2

... More
HDG LT 2 pin cross arm channel type HDG clamps & HDG nut bolts etc for 11.0 mts long RCC pole

21

1074

22558.2

... More
LT shackle insulator with Metal parts

135

372

50220

... More
Pole Numbering

22

104

2295.26

... More
3 Core XLPE cable 11 KV armoured cabled 300 sq.mm

50

2338

116900

... More
300 Sq mm Indoor Termination Kit

2

8840

17680

... More
H.S. 11 KV straight through joint 3 C 300 sq.mm.

1

29559

29559

... More
Supplying and filling in plinth under floors, trenches including watering ramming consolidating, dressing, complete. Sand. (0.4 x 0.2 x 40)

3.2

2170

6944

... More
Supply and laying of RCC protective covers of size 450mm long x 250mm width and 50mm thick capable of bearing load of 135Kg. And covered with earth/ sand upto depth of 0.15mts. Confirming to IS 1255-1967 at non-road crossing.

80

135

10800

... More
FRP Fencing complete with Gate as per specification for Distribution transformer (size 4 m x 3 m x 2m ) with Concreting for FRP Fencing supports with plinth ( 0.3 x 0.3 x 0.5) cum x 12 nos. each ration 1:3:6

11

76667

843337

... More
Cost of Erection

-

-

-

... More
3 WAY RMU, 11 KV, 630A, 21 kA 3 Sec, SF6 Outdoor RMU – 3LBS (a) Extensible / Non-Extensible Three (3) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (NI) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU. Auxiliary PT as per specification shall be provided in RMU.

1

9720

9720

... More
RCC pole 11.0 mtr long

22

9800

215600

... More
Stay set complete along with Stay rod with plate, Turnbuckle with eye bolt 11KV, Stay wire 7/10SWG, Break insulator, 8KV, Stay clamps, GI Nuts & Bolts 65 x 16 mm for 11.0 mtr RCC pole

22

2536

55799.48

... More
HDGI Structure Material

2860

47

134420

... More
11 KV GOAB 200 amps 3 pole with operating pipe support of class B, 25 mm dia.

11

3971

43681

... More
11KV, 200A Horn gap fuse unit (set of three)

11

3368

37048

... More
9KV, 5KA Lightning Arreastor pole mounted

33

174

5742

... More
Earthing complete with 40 mm GI pipe, 2.5 mtrs long along with 20 kgs each salt, charcoal complete

68

2444

166192

... More
MS Distribution box with MCCB 200 amps has bar made out of aluminium strips 40x10mm Other accessories, 3Ph energy meter, suitable CT's of 200/5 amps & MCCB 100A for 4 feeder arrangement of 100KVA distribution T/C

1

4687

4687

... More
MS Distribution box with MCCB 400 amps has bar made out of aluminium strips 40x10mm Other accessories, 3Ph energy meter, suitable CT's of 200/5 amps & MCCB 100A for 4 feeder arrangement of 100KVA distribution T/C

1

8795

8795

... More
Removing and refitting of Distribution boxes (M.S.) with 200 Amps MCCB and Kit Kat fuses

2

7030

14061

... More
Removing and refitting of Distribution boxes (M.S.) with 400 Amps MCCB and Kit Kat fuses

7

13192

92347.5

... More
Removing of Distribution boxes (M.S.) with 400 Amps MCCB and Kit Kat fuses

1

4397

4397.5

... More
300/5 LT CT ring type,measuring CT coil of rating300/5A,Class I accuracy, 50Hz, 660V, Burden:15VA conferming to IS2705/1992 as amended up to date 3ph, 4W, Electronic Trivector Meter,LT CT operated 3X240v /5A,50Hz,class 0.5s,Category a9forDTC) with Rs232 and Optical port and compliance to BIS ICs Doc: ETD 13(6211) april,2010.Polemounted MS Box(outdoor type )Electronic Meter as per Drawing No. EE/VIII/64(REV).1.1KV Multistrand copperconductor ,XLPE insulated,armoured control cable conferming to relevent IS amended up to date and of size 4 core x 2.5sq,mm.High grade 3/4" brass gland for 4 core 2.5sqmm. cable

4

1072

4288

... More
Removing and refitting of 300/5 LT CT ring type, measuring CT coil of rating300/5A,Class I accuracy, 50Hz, 660V, Burden:15VA conferming to IS2705/1992 as amended up to date 3ph, 4W, Electronic Trivector Meter,LT CT operated 3X240v /5A,50Hz,class 0.5s,Category a9forDTC) with Rs232 and Optical port and compliance to BIS ICs Doc: ETD 13(6211) april,2010.Polemounted MS Box(outdoor type )Electronic Meter as per Drawing No. EE/VIII/ 64(REV).1.1KV Multistrand copperconductor ,XLPE insulated,armoured control cable conferming to relevent IS amended up to date and of size 4 core x 2.5sq,mm.High grade 3/4" brass gland for 4 core 2.5sqmm. cable

7

1608

11256

... More
XLPE single core unarmoured 240 sq mm 1.1kv grade

384

200

76800

... More
XLPE Single Core unarmoured, 1.1 KV grade cable 185 sq.mm.

528

170

89760

... More
XLPE Single Core unarmoured 150 sq mm 1.1 KV grade

240

138

33120

... More
XLPE single core unarmoured 120 sq mm 1.1kv grade

624

95

59280

... More
XLPE Single Core unarmoured 50 sq mm 1.1 KV grade

550

56

30800

... More
Removing and rehoisting of 63 KVA 11kv/.4kv Distribution Transformer

1

16525

16525.5

... More
Removing and rehoisting of 100 KVA 11kv/.4kv Distribution Transformer

3

16525

49576.5

... More
Removing and rehoisting of 200 KVA 11kv/.4kv Distribution Transformer

7

23457

164199

... More
HDG cut point channel of ISMC 75x40x7.3mm 1.3 mtrs long with HDG clamps & HDG nut bolts etc for 11 mts long RCC pole

2

569

1138

... More
11 KV Disc insulator 45 KN with HDGI metal parts

27

332

8964

... More
ACSR Weasel Conductor 6/1/2.59 (nominal aluminium area 30 mm2) (139 amp max at 450C)

0.55

11000

6050

... More
Enamelled Danger Boards 440 Volts

22

57

1254

... More
Anticlimbing device

22

175

3850

... More
HDG LT 4 pin cross arm channel type HDG clamps & HDG nut bolts etc for 11.0 mts long RCC pole

21

338

7098

... More
HDG LT 2 pin cross arm channel type HDG clamps & HDG nut bolts etc for 11.0 mts long RCC pole

21

309

6489

... More
LT shackle insulator with Metal parts

135

208

28080

... More
Removing of RCC pole 9.0 mtr long

8

2950

23600

... More
Removing of M.S. Rail Poles 105 lb/yd 11 mtr

14

13317

186445

... More
Removing of HDGI Structure Material

2200

23

51700

... More
Removing of 11 KV GOAB 200 amps 3 pole with operating pipe support of class B, 25 mm dia.

11

1985

21840.5

... More
Removing of 11KV, 200A Horn gap fuse unit (set of three)

11

1684

18524

... More
Removing of 9KV, 5KA Lightning Arreastor pole mounted

33

87

2871

... More
Removing of XLPE single core unarmoured 240 sq mm 1.1kv grade

120

100

12000

... More
Removing of XLPE Single Core unarmoured, 1.1 KV grade cable 185 sq.mm.

96

85

8160

... More
Removing of XLPE single core unarmoured 120 sq mm 1.1kv grade

240

47

11400

... More
Removing of HDG cut point channel of ISMC 75x40x7.3mm 1.3 mtrs long with HDG clamps & HDG nut bolts etc for 11 mts long RCC pole

1

284

284.5

... More
Removing of HDG Cut point channel Cross arm channel alongwith clamps and nut bolts for 11 mtr 105 lb/yd rail pole

2

288

577

... More
Removing of 11 KV Disc insulator 45 KN with HDGI metal parts

27

166

4482

... More
Removing of Disc insulator 70 KN with metal parts

6

187

1125

... More
Removing of 11 KV pin insulator with HDG pin

3

76

228

... More
Removing of HDG LT 4 pin cross arm channel type HDG clamps & Nuts and bolts for 11.0 mts long rail pole

11

173

1903

... More
Removing of HDG LT 2 pin cross arm channel type HDG clamps & Nuts and bolts for 11.0 mts long rail pole

11

158

1743.5

... More
Removing of HDG LT 4 pin cross arm channel type HDG clamps & HDG nut bolts etc for 9.0 mts long RCC pole

9

159

1431

... More
Removing of HDG LT 2 pin cross arm channel type HDG clamps & HDG nut bolts etc for 9.0 mts long RCC pole

9

144

1300.5

... More
Removing of LT shackle insulator with Metal parts

115

104

11960

... More
Pole Numbering

22

-

-

... More
3 Core XLPE cable 11 KV armoured cabled 300 sq.mm

50

342

17100

... More
300 Sq mm Indoor Termination Kit

2

2548

5096

... More
H.S. 11 KV straight through joint 3 C 300 sq.mm.

1

3713

3713

... More
Earthwork in excavation by mechanical means (hydraulic excator) / manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5 m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : Hard rock where blasting is prohibited. (0.4 x 1.1 x 40 mtr)

17.6

763

13428.8

... More
Refilling the pipeline / foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer In Charge (0.4 x 0.9 x 40)

14.4

120

1728

... More
Supply and laying of RCC protective covers of size 450mm long x 250mm width and 50mm thick capable of bearing load of 135Kg. And covered with earth/ sand upto depth of 0.15mts. Confirming to IS 1255-1967 at non-road crossing.

80

60

4800

... More
FRP Fencing complete with Gate as per specification for Distribution transformer (size 4 m x 3 m x 2m ) with Concreting for FRP Fencing supports with plinth ( 0.3 x 0.3 x 0.5) cum x 12 nos. each ration 1:3:6

11

35000

385000

... More
Civil estimate for the work of RMU foundationfor erction of new 100 KVA DTC near ground in V.P Parsem

-

-

-

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 min width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : b)All types of Ordinary rock including all types of laterite rock, blasting prohibited

3.38

639

2159.82

... More
Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete.

0.18

2211

397.98

... More
Providing & laying cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded granitic or basaltic stone aggrt. 20 mm. nominal size) excluding cost of centering, shuttering and finishing in: a)All works upto plinth level

0.12

6325

759

... More
Providing and laying in position (1:11/2:3) Reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinfrocement (1 cement: 1½ coarse sand: 3 graded stone agg 20mm nominal size) a)All works upto plinth level

1.42

7178

10192.76

... More
Providing TMT steel reinforcement bars of (SAIL, TATA, VIZAG, JSW Steel Ltd.))(Confirming to IS 1786 of 1986) for RCC work (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in allthe floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member.

49.99

105

5248.95

... More
Centering & shuttering including Strutting, Propping & removal of forms for: i)Foundations, Footings, Bases for columns

6.3

407

2564.1

... More
12mm cement plaster 1:4 (1 cement : 4 fine sand)

3.51

223

782.73

... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge.

2.09

245

512.05



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.