Electricity Department Tender

View complete overview of Goa Electricity Department Tender

Electricity Department Tender

Works
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date27 Aug 2024
Closing Date14 Sep 2024
Tender Amount₹ 46,99,831 
Notes
Download

Costs

  • EMD

    ₹ 93,997
  • Document Cost

    ₹ 500
  • Tender Fee

    ₹ 6,000

Summary

Work Of Installation Of 02 Number Of 200kva Distribution Transformer Along With Associated Equipments At Dhavalkhajan And At Karai To Solve Low Voltage Problem Faced By The Residents Under Sub Div-iii, Canacona, Div-xvi, Margao

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of stay set for 7.5 Mtrs long RCC Pole as per technical specification

4

16272

4068.1

... More
Supply of HDGI stay rod with plate complete for 9 mts. Long RCC pole as per technical specification

5

21832

4366.54

... More
Supply of Enamelled danger board as per DRG No. CEE/490

2

496

248

... More
Supply, fabrication and transportation of Hot dip galvanised structure material for mounting Distribution box

53

8957

169

... More
Supply of HDGI L.A./S.A. cross arm clamps suitable for 9mts RCC pole as per Drg No. CEE/E-524.

8

2128

266

... More
Supply of HDGI L.A./S.A. cross arm clamps suitable for 7.5 RCC pole as per Drg No. CEE/E-524.

81

14904

184

... More
Supply of MS Distribution Box alongwith 12nos. 200A Kit Kat fuse and MCCB of 400Amps, 415 Volts. The box shall be fabricated with MS sheet 12 gauge with overlapping rain proof slit ventilators on both sides of the distribution box with wire mesh to prevent entry of insects with pin head door hinges locking arrangement and shall have required number of bus bars made out of Aluminium strips of size 40 x 10mm for connecting MCCB, fuses and cables (for 4 feeder arrangement) & other accessories.

2

126280

63140

... More
Supply of Loss Level-II 200KVA, 11/0.433KV 3 PH. Aluminium Wound Distribution Transformer as per technical specification.

2

754810

377405

... More
Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete with brick masonary.

10

44280

4428

... More
Supply of AAC ' ANT ' conductor of size 7/3.14mm. The stringing rate includes transportation, jointing, etc. 7.44 Kms of conductor shall be strung as phases for LT line. The conductor shall be comply to the technical specification.

8.4

403922

48086

... More
Supply of AAC ' GNAT ' size 7/2.21mm conductor for neutral, streetlight and jumpering as well as guarding. The conductor shall be comply to technical specification.

8.8

222578

25293

... More
Supply of HDGI 4 pin LT cross arm channel type 75 X 40mm 1.5 mtr long as per Drg. No. CEE/E/705.

54

59886

1109

... More
Supply of HDGI 2 pin LT cross arm channel type 75 X 40 mm 0.75 mtr long as per Drg. No. CEE/E/704.

47

26743

569

... More
Supply of Single Phase 4KVA CCMS panel

1

23417

23417

... More
Supply of a) L.T. brown glazed porcelain pin insulators of size 100mm x 70mm conforming to type 1 fig 1 of IS:1445/1977 with amendment 2 of Feb.1981 (second revision) as amended upto date. Minimum failing load shall be 3.5kN & b) Forged G. I. Pin conforming to IS 7935/1975 as amended upto date suitable for L.T. porcelain pin insulator type 1 conforming to fig.1 of IS: 1445/77 with amendment No. 2, Feb.1981, of size 100 x 70 mm.

140

36820

263

... More
Supply of a) L.T. brown glazed shackle insulators of size 100mm x 115mm conforming to fig.No.4 and type 2 of IS: 1445/77 as amended upto date. Minimum failing load shall be 16kN & b) G. I hardware suitable for L. T. shackle insulators of size 100 x 115 mm. conforming to type 2, fig. 4 of IS: 1445/77 as amended upto date. Hardware or fitting shall conform to fig. 4 of IS 7935-1975 as amended up to date, comprise of 2 G. I. strips, 2 G. I. bolts and 2 nuts with spring washers.

240

89280

372

... More
Supply HDGI G.I. Hexagonal head bolts and hexagonal nuts conforming to IS 1363 part I to III 1992 as amended upto date of the size 3 ½" x 5/8" or 4" x 5/8",6"x5/8", 8"x5/8" or as per the requirement.

47.5

10830

228

... More
Providing of Low Tension metering to the DTC by Suplying, Installing and commissioning of following Materials: 1) Epoxy resin Cast L.T. CT coil of 300/5A, Class-0.5s, 50Hz,660V, Burden 15VA conforming to IS-2705 / 1992 as amended upto date 2) Electronic 3Phase,4wire ,Trivector Meter ,LT CT operated 3x240V,-/5A,50Hz, class 0.5s, Category "A" (DLMS COSEM Protocol) for DTC with RS 232 Optical port and complience to BIS ICS Doc: ETD 13(6211) and latest. 3) 1.1KV multistand copper conductor 2.5sq.mm, XLPE insulated, armoured control cable conforming to relevant IS amended upto date.4) Pole mounted M.S Box ( outdoor type) for Electronic Meter as Drawing No.EE/VIII/64(REV) 5 Al. L shape flat 40mm suitable for mounting on bushing rod and brass lug

2

51376

25688

... More
Supply of CAMR Modem as per technical specification.

2

12000

6000

... More
Supply of XLPE cable armoured 3& 1/2 C 185 sq.mm 1.1 KV Grade

20

26680

1334

... More
Supply of XLPE cable armoured 3 ½ core 120sqmm 1.1kv grade.

60

54780

913

... More
Supply of Aluminium Lugs, size 185 sq.mm as per technical specification

12

936

78

... More
Supply of Aluminium Lugs, size 120 sq.mm as per technical specification

20

1080

54

... More
Supply of XLPE cable 11KV 3C X 300 sq.mm armoured

40

93520

2338

... More
Supply of XLPE cable 11KV 3C X 95 sq.mm armoured

24

27048

1127

... More
Supply of H.S 11K V Straight through joint 3 core, 300 SQMM

4

118236

29559

... More
Supply of H.S.11 KV Termination kit indoor 300 sqmm. XLPE 3 core

4

35360

8840

... More
Supply of H.S.11 KV Termination kit indoor 95 sqmm. XLPE 3 core

2

13462

6731

... More
Supply of H.S.11 KV Termination kit outdoor 95 sqmm. XLPE 3 core

2

20304

10152

... More
3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 1CB Extensible/Non-Extensible Two (2) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 and One (1) vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.

2

1130000

565000

... More
Supply and filling of sand in plinth uner floors , trenches including waterin ,ramming consolidating, dressing complete.

5.5

11935

2170

... More
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size)excluding cos t of centering and shuttering and finishing for foundations.ALL WORKS UPTO PLINTH LEVEL

1.22

6777

5555

... More
Providing Centering and shuttering including struttings, propping etc and removal of formwork

9.39

5286

563

... More
Supply and Providing of 12mm cement plaster 1:4 (1 - cement: 4 - fine sand) for foundations.

15.71

2309

147

... More
Brick work using common burnt building bricks in cement mortar 1:4 (1 cement : 4 coarse sand) with bricks of class designation 75 kgs/ cm2 (wire cut bricks)

9.6

71193

7416

... More
Supply of burnt clay wire cut bricks of 75 Kgs/cm2 class.Wire cut bricks.

100

950

9.5

... More
Supply of FRP Fencing complete with Gate around every distribution sub station containing RMU, one distribution transformer and LV switchboardincluding danger plate (Size 6M X 3M X 2M)with concreting for FRP fencingsupport with plinth(0.3x03x0.5) cu.mts x18 nos. Each ratio 1:3:6

2

217540

108770

... More
Supply of protective cover of size 600mm long x 250mm width and 50mm thick capable of bearing load of 135 Kg and covered with earth/sand upto depth of 0.15 mts. Confirming to IS 1255-1967 at non road crossing.

34

4318

127

... More
Supply of Class B HDGI pipe of diameter 100 mm dia for cable rising.

12

9732

811

... More
Supply of GI Flat 25 x 5 mm.

50

5800

116

... More
Supply of RCC Cable route Marker

2

1056

528

... More
COST OF ERECTION

-

-

-

... More
Erection of 9.0 meters long R.C.C. Pole.

6

35400

5900

... More
Erection of 7.5 meters long R.C.C. Pole.

7

36400

5200

... More
Erection of stay set for 7.5 Mtrs long RCC Pole as per technical specification

4

9612

2403

... More
Erection of HDGI stay rod with plate complete for 9 mts. Long RCC pole as per technical specification

5

12325

2465.08

... More
Erection of Enamelled danger board as per DRG No. CEE/490

2

114

57

... More
Erection of Hot dip galvanised structure material for mounting Distribution box

53

2491

47

... More
Fixing of HDGI L.A./S.A. cross arm clamps suitable for 9mts RCC pole as per Drg No. CEE/E-524.

8

360

45

... More
Fixing of HDGI L.A./S.A. cross arm clamps suitable for 7.5 RCC pole as per Drg No. CEE/E-524.

81

2592

32

... More
Erection and commissioning of MS Distribution Box alongwith 12nos. 200A Kit Kat fuse and MCCB of 400Amps, 415 Volts. The box shall be fabricated with MS sheet 12 gauge with overlapping rain proof slit ventilators on both sides of the distribution box with wire mesh to prevent entry of insects with pin head door hinges locking arrangement and shall have required number of bus bars made out of Aluminium strips of size 40 x 10mm for connecting MCCB, fuses and cables (for 4 feeder arrangement) & other accessories.

2

17590

8795

... More
Erection, testing and commissioning of Loss Level-II 200KVA, 11/0.433KV 3 PH. Aluminium Wound Distribution Transformer as per technical specification.

2

31276

15638

... More
Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete with brick masonary.

10

26650

2665

... More
Stringing of AAC ' ANT ' conductor of size 7/3.14mm. The stringing rate includes transportation, jointing, etc. 7.44 Kms of conductor shall be strung as phases for LT line. The conductor shall be comply to the technical specification.

8.4

86520

10300

... More
Stringing of AAC ' GNAT ' size 7/2.21mm conductor for neutral, streetlight and jumpering as well as guarding. The conductor shall be comply to technical specification.

8.8

80080

9100

... More
Fixing of HDGI 4 pin LT cross arm channel type 75 X 40mm 1.5 mtr long as per Drg. No. CEE/E/705.

54

14094

261

... More
Fixing of HDGI 2 pin LT cross arm channel type 75 X 40 mm 0.75 mtr long as per Drg. No. CEE/E/704.

47

10904

232

... More
Fixing of Single Phase 4KVA CCMS panel

1

900

900

... More
Fixing of a) L.T. brown glazed porcelain pin insulators of size 100mm x 70mm conforming to type 1 fig 1 of IS:1445/1977 with amendment 2 of Feb.1981 (second revision) as amended upto date. Minimum failing load shall be 3.5kN & b) Forged G. I. Pin conforming to IS 7935/1975 as amended upto date suitable for L.T. porcelain pin insulator type 1 conforming to fig.1 of IS: 1445/77 with amendment No. 2, Feb.1981, of size 100 x 70 mm.

140

24220

173

... More
Fixing of a) L.T. brown glazed shackle insulators of size 100mm x 115mm conforming to fig.No.4 and type 2 of IS: 1445/77 as amended upto date. Minimum failing load shall be 16kN & b) G. I hardware suitable for L. T. shackle insulators of size 100 x 115 mm. conforming to type 2, fig. 4 of IS: 1445/77 as amended upto date. Hardware or fitting shall conform to fig. 4 of IS 7935-1975 as amended up to date, comprise of 2 G. I. strips, 2 G. I. bolts and 2 nuts with spring washers.

240

49920

208

... More
Fixing HDGI G.I. Hexagonal head bolts and hexagonal nuts conforming to IS 1363 part I to III 1992 as amended upto date of the size 3 ½" x 5/8" or 4" x 5/8",6"x5/8", 8"x5/8" or as per the requirement.

47.5

1425

30

... More
Providing of Low Tension metering to the DTC by Suplying, Installing and commissioning of following Materials: 1) Epoxy resin Cast L.T. CT coil of 300/5A, Class-0.5s, 50Hz,660V, Burden 15VA conforming to IS-2705 / 1992 as amended upto date 2) Electronic 3Phase,4wire ,Trivector Meter ,LT CT operated 3x240V,-/5A,50Hz, class 0.5s, Category "A" (DLMS COSEM Protocol) for DTC with RS 232 Optical port and complience to BIS ICS Doc: ETD 13(6211) and latest. 3) 1.1KV multistand copper conductor 2.5sq.mm, XLPE insulated, armoured control cable conforming to relevant IS amended upto date.4) Pole mounted M.S Box ( outdoor type) for Electronic Meter as Drawing No.EE/VIII/64(REV) 5 Al. L shape flat 40mm suitable for mounting on bushing rod and brass lug

2

2144

1072

... More
Fixing of CAMR Modem as per technical specification.

2

-

-

... More
Erection of XLPE cable armoured 3& 1/2 C 185 sq.mm 1.1 KV Grade

20

4560

228

... More
Erection of XLPE cable armoured 3 ½ core 120sqmm 1.1kv grade.

60

10560

176

... More
Crimping of Aluminium Lugs, size 185 sq.mm as per technical specification

12

1140

95

... More
Crimping of Aluminium Lugs, size 120 sq.mm as per technical specification

20

1760

88

... More
Erection of XLPE cable 11KV 3C X 300 sq.mm armoured

40

13680

342

... More
Erection of XLPE cable 11KV 3C X 95 sq.mm armoured

24

4776

199

... More
Erection of H.S 11K V Straight through joint 3 core, 300 SQMM

4

14852

3713

... More
Erection of H.S.11 KV Termination kit indoor 300 sqmm. XLPE 3 core

4

10192

2548

... More
Erection of H.S.11 KV Termination kit indoor 95 sqmm. XLPE 3 core

2

5076

2538

... More
Erection of H.S.11 KV Termination kit outdoor 95 sqmm. XLPE 3 core

2

5296

2648

... More
3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 1CB Extensible/Non-Extensible Two (2) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 and One (1) vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.

2

19440

9720

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in

15.19

7108

468

... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge.

9.85

1182

120

... More
Disposal of exavated soil

5.34

671

125.82

... More
Erection of FRP Fencing complete with Gate around every distribution sub station containing RMU, one distribution transformer and LV switchboardincluding danger plate (Size 6M X 3M X 2M)with concreting for FRP fencingsupport with plinth(0.3x03x0.5) cu.mts x18 nos. Each ratio 1:3:6

2

70000

35000

... More
Laying of protective cover of size 600mm long x 250mm width and 50mm thick capable of bearing load of 135 Kg and covered with earth/sand upto depth of 0.15 mts. Confirming to IS 1255-1967 at non road crossing.

34

2856

84

... More
Laying of Class B HDGI pipe of diameter 100 mm dia for cable rising.

12

1104

92

... More
Erection of GI Flat 25 x 5 mm.

50

2400

48

... More
Erection of RCC Cable route Marker

2

512

256

... More
Removing of the existing 7.5 m RCC pole and handing over to Sub-Divisional Engineer against acknowledgement as per technical specification.

7

18200

2600

... More
Removing and re-fixing of the existing service conenction single phase.-(PVC wire 2C x 4sq.mm 1.1 KV Grade)

2020

24240

12

... More
Removing and re-fixing of the existing service conenction three phase.(PVC wire 2C x 6sq.mm 1.1 KV Grade)

1965

26527

13.5

... More
Removing of 4 Pin cross arms assembly with Clamps, Nut & Bolt for 7.5/ 9.00 Mtr RCC poles/ rail pole as per technical specification.

50

7325

146.5

... More
Removing of 2 Pin cross arms assembly with Clamps, Nut & Bolt as per technical specification.

43

5676

132

... More
Removing of LT shackle insulator with metal parts and handing over to the concerned Sub-divisional Engineer against acknowledgement.

216

22464

104

... More
Removing of LT Pin Insulator with G.I. pin and handing over to the concerned Sub-divisional Engineer against acknowledgement.

140

12110

86.5

... More
Removing of the existing Old deteriorated ANT conductor as per technical specification.

8.43

43414

5150

... More
Removing of the existing Old deteriorated GNAT conductor as per technical specification.

7.4

33670

4550

... More
Removing & Re Fixing of LED Street Lights

7

4200

600

... More
Removing & Re fixing of Eixing of Street Light clamp 25mm pipe (Top/bottom)

14

882

63

... More
Removing & Re Fixing of G.I Bent Pipe 1mx25mm

7

861

123



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.