Electricity Department Tender
View complete overview of Goa Electricity Department Tender
Costs
EMD
₹ 44,023Document Cost
₹ 500Tender Fee
₹ 4,402
Summary
The Work Of Enhancement Of 200kva Shirodkar Dtc To 400kva And Converting Its Overhead Lt Line To Underground System At Old Goa In View Of Sfx Exposition 2024
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_ED_18070_1Bid Award Id
ViewTender No
15(2024-25)Tender Authority
Electricity Department ViewPurchaser Address
-
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply of Earthing complete with 40mm GI pipe, 2.5mtrs long alongwith 20kgs each salt, charcoal complete
6
2730
16380
Supply of LV switch board suitable for 400KVA transformer Centre out door made CRCA sheet with PU painted and complete with all accessories and HDGI mounting channels.
1
300950
300950
Supply of 3 phase, 415V, 2nos of 200Amps incoming 3Phase and N, 415V 200A MCCBs outgoing, 12 Nos. . 32Amps SP MCBs, 12nos 16Amps SP MCBs Distribution Service Pillar suitable for outdoor installation , made out of CRCA sheet with PU painted complete with all accesories and HDGI mounting channels (Note : considered 24 way SP MCBs)
3
84276
252828
Supply of unarmoured single core 300sqmm XLPE 1.1 KV grade to be laid from transformer to LV Panel
80
555
44400
Supply of XLPE cable armoured 3 ½ C X 120 sq.mm 1.1 KV Grade
350
945
330750
Supply of 4 core, 25sq.mm, stranded Aluminium conductor, PVC insulated, 1.1KV grade armoured power cable and carrying ISI MARK
1000
280
280000
Supply of 4 core 16 sq. mm stranded Aluminium, Armoured, PVC insulated Cables. The cable shall carry concerned ISI mark
500
290
145000
Supply of indoor type, Heat shrinkable, three phase, end terminating kit complete with sockets/lugs for 11KV(E) XLPE cable of size 3 core 95sq.mm
1
6731
6731
Supply of Distribution Transformer Metering Unit
1
25688
25688
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means in foundation pipeline trenches drain( not exceeding 1.5 mt in width or 10 sq.m on plan) includingdressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposl of surplus excavated soil as directed within a lead of 50 m(a) for laying of HT/ LT cables of various sizes including excavation for equipment foundation i.e for
168
-
-
Refilling the foundations, trenches, plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth, cosolidating each layer by ramming and watering lead upto. 50 M and all lifts and disposal of surplus earth in cable trenches and foundations of poles and equipments.
120
-
-
Supply of fine river sand of approved quality (except in sandy soil) for cushioning of HT/LT underground cables laid by conventional Open Trenching Method.
48
2170
104160
Providing of cement concrete 1:3:6( 1 cement; 3 coarse sand; 6 graded granitic or basaltic stone aggregate.) for foundations of 1) SERVICE PILLAR 2) STREETLIGHT PILLAR 3) STREET LIGHT POLES ETC.
8
5555
44440
Providing of Centering & shuttering including Strutting, Propping & removal of forms for sloping or battering surface (slabs, beams, louvers, etc) including folded plates. I. Where inclination to the horizontal does not exceed 30° requiring shuttering on the underside only
2.1
805
1690.5
Providing of in position (1:11/2:3) Reinforced cement conrete excluding the cost of centering, shuttering, finishing and reinfrocement (1 cement: 1½ coarse sand:3 graded stone agg 20mm nominal size) a. All works upto plinth level
1.5
7178
10767
Providing of 12mm cement plaster 1:4 (1 - cement: 4 - fine sand) for foundations.
2.3
223
512.9
Supply of Underground cable protective cover as per specs. The concrete slab shall be machine made using semi dry concrete that is batched in a fully automatic PLC controlled concrete batching plant and cast in a fully automatic "Vibro-press" machine with a high vibration frequency and hydraulic presuure of 40 MT, the size of the slab shall be 480mm*250mm*50mm and the concrete grade shall be M30 Adhring to IS 456l:2000 and shall have a minimum crushing strength of 30 N/mm2 (28 days strength) when tested.
1000
135
135000
Providing of Centering & shuttering including struttings, propping etc and removal of formwork for a) Foundations, footings, bases of columns and mass concrete
20
563
11260
Supply of Enamelled Danger Board
2
248
496
Supply of HDG nut bolts
10
228
2280
Supply GI PIPE FOR ROAD CROSSING
20
1681
33620
Supply of RCC Hume pipes for road crossings, of 100 mm inner diameter, alongwith required no. of collars, PCC and Masonary work as per technical specifications.
20
488
9760
Supply of GI Flat 25X5mm
20
116
2320
Erection, Testing & Commissioning
-
-
-
Erection Testing & Commissioning of 400 KVA 11kv/.4kv Distribution Transformers level I losses, Copper Winding, with Bimetallic Terminal Connectors, Energy Efficiency Level-II as per IS: 1180 (Part-I): 2014, suitable for outdoor use and for plinth mounting.
1
18357
18357
Removing of 200 KVA 11kv/.4kv Distribution Transformer
1
7819
7819
Erection Testing & Commissioning of Earthing complete with 40mm GI pipe, 2.5mtrs long alongwith 20kgs each salt, charcoal complete
6
2444
14664
Erection Testing & Commissioning of LV switch board suitable for 400KVA transformer incuding foundation erection,comissioning inclusive of 1600a ACB for incomer and 4nos of 400A MCCB for outgoing feeders with separate compartment for metering arragment and energy meter including foundation
1
12500
12500
Erection Testing & Commissioning of 3 phase, 415V, 2nos of 200Amps incoming 3Phase and N, 415V 200A MCCBs outgoing, 12 Nos. 32Amps SP MCBs, 12nos 16Amps SP MCBs Distribution Service Pillar suitable for outdoor installation , made out of CRCA sheet with PU painted complete with all accesories and HDGI mounting channels (Note : considered 24 way SP MCBs)
3
4183
12549
Erection Testing & Commissioning of unarmoured single core 300sqmm XLPE 1.1 KV grade to be laid from transformer to LV Panel
80
218
17440
Erection Testing & Commissioning of XLPE cable armoured 3 ½ C X 120 sq.mm 1.1 KV Grade
350
176
61600
Erection Testing & Commissioning of 4 core, 25sq.mm, stranded Aluminium conductor, PVC insulated, 1.1KV grade armoured power cable and carrying ISI MARK
1000
94
94000
Erection Testing & Commissioning of 4 core 16 sq. mm stranded Aluminium, Armoured, PVC insulated Cables. The cable shall carry concerned ISI mark
500
80
40000
Erection Testing & Commissioning of indoor type, Heat shrinkable, three phase, end terminating kit complete with sockets/lugs for 11KV(E) XLPE cable of size 3 core 95sq.mm
1
2538
2538
Erection Testing & Commissioning of Distribution Transformer Metering Unit
1
1072
1072
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means in foundation pipeline trenches drain( not exceeding 1.5 mt in width or 10 sq.m on plan) includingdressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposl of surplus excavated soil as directed within a lead of 50 m(a) for laying of HT/ LT cables of various sizes including excavation for equipment foundation i.e for
168
468
78624
Refilling the foundations, trenches, plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth, cosolidating each layer by ramming and watering lead upto. 50 M and all lifts and disposal of surplus earth in cable trenches and foundations of poles and equipments.
120
120
14400
Supply and laying of fine river sand of approved quality (except in sandy soil) for cushioning of HT/LT underground cables laid by conventional Open Trenching Method.
48
-
-
Laying of cement concrete 1:3:6( 1 cement; 3 coarse sand; 6 graded granitic or basaltic stone aggregate.) for foundations of 1) SERVICE PILLAR 2) STREETLIGHT PILLAR 3) STREET LIGHT POLES ETC.
8
-
-
Centering & shuttering including Strutting, Propping & removal of forms for sloping or battering surface (slabs, beams, louvers, etc) including folded plates. I. Where inclination to the horizontal does not exceed 30° requiring shuttering on the underside only
2.1
-
-
Laying in position (1:11/2:3) Reinforced cement conrete excluding the cost of centering, shuttering, finishing and reinfrocement (1 cement: 1½ coarse sand:3 graded stone agg 20mm nominal size) a. All works upto plinth level
1.5
-
-
12mm cement plaster 1:4 (1 - cement: 4 - fine sand) for foundations.
2.3
-
-
Laying of Underground cable protective cover as per specs. The concrete slab shall be machine made using semi dry concrete that is batched in a fully automatic PLC controlled concrete batching plant and cast in a fully automatic "Vibro-press" machine with a high vibration frequency and hydraulic presuure of 40 MT, the size of the slab shall be 480mm*250mm*50mm and the concrete grade shall be M30 Adhring to IS 456l:2000 and shall have a minimum crushing strength of 30 N/mm2 (28 days strength) when tested.
1000
60
60000
Erection of Centering & shuttering including struttings, propping etc and removal of formwork for a) Foundations, footings, bases of columns and mass concrete
20
-
-
Erection of Enamelled Danger Board
2
57
114
Erection of HDG nut bolts
10
30
300
Erection of GI PIPE FOR ROAD CROSSING
20
182
3640
Erection of RCC Hume pipes for road crossings, of 100 mm inner diameter, alongwith required no. of collars, PCC and Masonary work as per technical specifications.
20
77
1540
Erection Testing & Commissioning of GI Flat 25X5mm
20
48
960
Evaluation Notes How It Works ?