Electricity Department Tender

View complete overview of Goa Electricity Department Tender

Electricity Department Tender

Works
Energy, Oil and Gas
Eprocure
Opening Date3 Jan 2025
Closing Date18 Jan 2025
Tender Amount₹ 4,87,05,274 
Notes
Download

Costs

  • EMD

    ₹ 9,74,105
  • Document Cost

    ₹ 1,500
  • Tender Fee

    ₹ 6,000

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 3LBS Extensible/Non Extensible Three (3) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU , modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.

2

585000

1170000

... More
HDGI flat of size 25mm x 5mm for earthing.

10

116

1160

... More
Supply and erection testing and commissioning of Indoor type, Heat shrinkable, three phase, end terminating kit complete with sockets/plugs for 11KV (E) XLPE cable of size 3 crore 185 sqmm for connecting RMU.

6

7873

47238

... More
Supply and erection of 11 KV 3 core straight through jointing kit suitable for 185 sq.mm XLPE Cable

4

27079

108316

... More
RCC Cable route marker (400 x 900 x 100mm) (as per CEE approved drawing, copy enclosed)

15

528

7920

... More
Supply laying connecting & commissioning H.D.G.I. earting pipe 2.5 mts long with 40 mm nominal bore, fabricated & perforated including alternate layers 30cm thick of charcoal, salt -10kg each per pit) inclusive of excavation backfilling & spreading of excavated earth evenly in all kinds of soil complete with chamber of Brick masonary and CI cover.

4

4428

17712

... More
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size for foundations.

6

6635

39810

... More
COST OF ERECTION

-

-

-

... More
3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 3LBS Extensible/Non Extensible Three (3) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU , modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.

2

9720

19440

... More
RMU foundation works as per civil estimate

1

12840

12840.93

... More
HDGI flat of size 25mm x 5mm for earthing.

10

48

480

... More
Supply and erection testing and commissioning of Indoor type, Heat shrinkable, three phase, end terminating kit complete with sockets/plugs for 11KV (E) XLPE cable of size 3 crore 185 sqmm for connecting RMU.

6

2548

15288

... More
Supply and erection of 11 KV 3 core straight through jointing kit suitable for 185 sq.mm XLPE Cable

4

3450

13800

... More
RCC Cable route marker (400 x 900 x 100mm) (as per CEE approved drawing, copy enclosed)

15

256

3840

... More
Supply laying connecting & commissioning H.D.G.I. earting pipe 2.5 mts long with 40 mm nominal bore, fabricated & perforated including alternate layers 30cm thick of charcoal, salt -10kg each per pit) inclusive of excavation backfilling & spreading of excavated earth evenly in all kinds of soil complete with chamber of Brick masonary and CI cover.

4

2665

10660

... More
Laying of 11KV/LT UG cables bytrenchless technology by adopting horizontal directional drilling (HDD method). The work includes preparation of site, Boring as well as drawing of cable In Hard/Laterite stone with minimum 8" bore size, including Supply and erection of HDPE pipe 110mm, PN6, PE80, wall thickness 6.5 mm (minimum) as per IS 4984:1995 amendment 2016. The depth shall be 1.650m to 1.850m (1650mm-1850mm only except at entry and exit pits where minimum depth shall be 1200mm.

270

3600

972000

... More
Laterite Masonary Works:- Rubble packing with hard Laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other fondations complete, for: Single Circuit 11KV Cable Trench ( 0.2 x 0.7 x 1.00) i.e. 0.14 per RM

8

2211

17688

... More
B.S-II Work of Laying of Underground cable through HDD method for Connecting 11 KV Royal Enfield feeder to 11kv Sauntavaddo feeder from 33/11KV Nagoa SubStation under Sub Div IV

-

-

-

... More
COST OF MATERIAL

-

-

-

... More
Supply, storage, transportation to worksite, laying, termination, testing, and commissioning of KV XLPE, 3 core, 300 Sqmm, Aluminium,XLPE insulated, flat strip armoured, 11KV (Earthed) Cable type A2xwy conforming I.S. 7098 PART 2 and carrying ISI MARK

1030

2595

2672850

... More
3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 3LBS Extensible/Non Extensible Three (3) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU , modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.

1

585000

585000

... More
Supply and erection testing and commissioning of Indoor type, Heat shrinkable, three phase, end terminating kit complete with sockets/plugs for 11KV (E) XLPE cable of size 3 crore 300 sqmm for connecting RMU.

5

8840

44200

... More
H S 11 kv straight through joint 3 core 300 sqmm XLPE cable

3

29559

88677

... More
RCC Cable route marker (400 x 900 x 100mm) (as per CEE approved drawing, copy enclosed)

15

528

7920

... More
HDGI flat of size 25mm x 5mm for earthing.

5

116

580

... More
Supply laying connecting & commissioning H.D.G.I. earting pipe 2.5 mts long with 40 mm nominal bore, fabricated & perforated including alternate layers 30cm thick of charcoal, salt -10kg each per pit) inclusive of excavation backfilling & spreading of excavated earth evenly in all kinds of soil complete with chamber of Brick masonary and CI cover.

2

4428

8856

... More
COST OF ERECTION

-

-

-

... More
3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 3LBS Extensible/Non Extensible Three (3) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU , modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.

1

9720

9720

... More
RMU foundation works as per civil estimate

1

12840

12840.93

... More
Supply and erection testing and commissioning of Indoor type, Heat shrinkable, three phase, end terminating kit complete with sockets/plugs for 11KV (E) XLPE cable of size 3 crore 300 sqmm for connecting RMU.

5

2548

12740

... More
H S 11 kv straight through joint 3 core 300 sqmm XLPE cable

3

3713

11139

... More
RCC Cable route marker (400 x 900 x 100mm) (as per CEE approved drawing, copy enclosed)

15

256

3840

... More
HDGI flat of size 25mm x 5mm for earthing.

5

48

240

... More
Supply laying connecting & commissioning H.D.G.I. earting pipe 2.5 mts long with 40 mm nominal bore, fabricated & perforated including alternate layers 30cm thick of charcoal, salt -10kg each per pit) inclusive of excavation backfilling & spreading of excavated earth evenly in all kinds of soil complete with chamber of Brick masonary and CI cover.

2

2665

5330

... More
Laying of 11KV/LT UG cables bytrenchless technology by adopting horizontal directional drilling (HDD method). The work includes preparation of site, Boring as well as drawing of cable In Hard/Laterite stone with minimum 8" bore size, including Supply and erection of HDPE pipe 110mm, PN6, PE80, wall thickness 6.5 mm (minimum) as per IS 4984:1995 amendment 2016. The depth shall be 1.650m to 1.850m (1650mm-1850mm only except at entry and exit pits where minimum depth shall be 1200mm.

1095

3600

3942000

... More
Laterite Masonary Works:- Rubble packing with hard Laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other fondations complete, for: Single Circuit 11KV Cable Trench ( 0.2 x 0.7 x 1.00) i.e. 0.14 per RM

10.95

2211

24210.45

... More
B.S-III Work of Laying of Underground cable through HDD method for Connecting 11 KV Dharwadkar feeder to 11kv Baga from 33/11KV Nagoa SubStation under Sub Div IV.

-

-

-

... More
COST OF MATERIAL

-

-

-

... More
Supply, storage, transportation to worksite, laying, termination, testing, and commissioning of KV XLPE, 3 core, 300 Sqmm, Aluminium,XLPE insulated, flat strip armoured, 11KV (Earthed) Cable type A2xwy conforming I.S. 7098 PART 2 and carrying ISI MARK

1922

2595

4987590

... More
Sand for cushioning of HT underground cables.

4.5

2170

9765

... More
RCC Protective covers for XLPE insulated, round wire armoured, 11KV cable

1968

135

265680

... More
3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 3LBS Extensible/Non Extensible Three (3) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU , modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.

2

585000

1170000

... More
Supply and erection testing and commissioning of Indoor type, Heat shrinkable, three phase, end terminating kit complete with sockets/plugs for 11KV (E) XLPE cable of size 3 crore 300 sqmm for connecting RMU.

4

8840

35360

... More
RCC Cable route marker (400 x 900 x 100mm) (as per CEE approved drawing, copy enclosed)

15

528

7920

... More
H S 11 kv straight through joint 3 core 300 sqmm XLPE cable

8

29559

236472

... More
HDGI flat of size 25mm x 5mm for earthing.

10

116

1160

... More
Supply, storage, transportation to worksite, laying, termination, testing, and commissioning of KV XLPE, 3 core, 185 Sqmm, Aluminium,XLPE insulated, flat strip armoured, 11KV (Earthed) Cable type A2xwy conforming I.S. 7098 PART 2 and carrying ISI MARK

50

1780

89000

... More
Supply and erection testing and commissioning of Indoor type, Heat shrinkable, three phase, end terminating kit complete with sockets/plugs for 11KV (E) XLPE cable of size 3 crore 185 sqmm for connecting RMU.

2

7873

15746

... More
Supply and erection of 11 KV 3 core straight through jointing kit suitable for 185 sq.mm XLPE Cable

2

27079

54158

... More
Supply laying connecting & commissioning H.D.G.I. earting pipe 2.5 mts long with 40 mm nominal bore, fabricated & perforated including alternate layers 30cm thick of charcoal, salt -10kg each per pit) inclusive of excavation backfilling & spreading of excavated earth evenly in all kinds of soil complete with chamber of Brick masonary and CI cover.

4

4428

17712

... More
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size for foundations.

6

6635

39810

... More
COST OF ERECTION

-

-

-

... More
Filling up of available excavated earth (excluding rock/stones)in trenches, plinth,sides foundation etc in layer not exceeding 0.2mt depth con-solidating each deposited layer by ramming and watering.

15.75

120

1890

... More
Disposal of surplus excavated soil / material by mechanical transportation including loading and unloading, stacking/levelling as directed within a distance of 2500mts

67.58

125

8502.92

... More
RCC Protective covers for XLPE insulated, round wire armoured, 11KV cable

1968

60

118080

... More
3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 3LBS Extensible/Non Extensible Three (3) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU , modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.

2

9720

19440

... More
RMU foundation works as per civil estimate

1

25703

25703.97

... More
Supply and erection testing and commissioning of Indoor type, Heat shrinkable, three phase, end terminating kit complete with sockets/plugs for 11KV (E) XLPE cable of size 3 crore 300 sqmm for connecting RMU.

4

2548

10192

... More
RCC Cable route marker (400 x 900 x 100mm) (as per CEE approved drawing, copy enclosed)

15

256

3840

... More
H S 11 kv straight through joint 3 core 300 sqmm XLPE cable

8

3713

29704

... More
HDGI flat of size 25mm x 5mm for earthing.

10

48

480

... More
Supply, storage, transportation to worksite, laying, termination, testing, and commissioning of KV XLPE, 3 core, 185 Sqmm, Aluminium,XLPE insulated, flat strip armoured, 11KV (Earthed) Cable type A2xwy conforming I.S. 7098 PART 2 and carrying ISI MARK

50

263

13150

... More
Supply and erection testing and commissioning of Indoor type, Heat shrinkable, three phase, end terminating kit complete with sockets/plugs for 11KV (E) XLPE cable of size 3 crore 185 sqmm for connecting RMU.

2

2548

5096

... More
Supply and erection of 11 KV 3 core straight through jointing kit suitable for 185 sq.mm XLPE Cable

2

3450

6900

... More
Supply laying connecting & commissioning H.D.G.I. earting pipe 2.5 mts long with 40 mm nominal bore, fabricated & perforated including alternate layers 30cm thick of charcoal, salt -10kg each per pit) inclusive of excavation backfilling & spreading of excavated earth evenly in all kinds of soil complete with chamber of Brick masonary and CI cover.

4

2665

10660

... More
Laying of 11KV/LT UG cables bytrenchless technology by adopting horizontal directional drilling (HDD method). The work includes preparation of site, Boring as well as drawing of cable In Hard/Laterite stone with minimum 8" bore size, including Supply and erection of HDPE pipe 110mm, PN6, PE80, wall thickness 6.5 mm (minimum) as per IS 4984:1995 amendment 2016. The depth shall be 1.650m to 1.850m (1650mm-1850mm only except at entry and exit pits where minimum depth shall be 1200mm.

1902

3600

6847200

... More
Laterite Masonary Works:- Rubble packing with hard Laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other fondations complete, for: Single Circuit 11KV Cable Trench ( 0.2 x 0.7 x 1.00) i.e. 0.14 per RM

30

2211

66330

... More
B.S-IV Work of Linking of 11KV Tivaiwaddo feeder from Pinto DEOS to 11KV Caculo feeder at Andores junction emanating from 33/11KV GIS Calangute substation inorder to provide ring feed arrangement under the jurisdiction of S/D IV CALANGUTE

-

-

-

... More
COST OF MATERIAL

-

-

-

... More
Sand for cushioning of HT underground cables.

84.96

2170

184363.2

... More
supply and laying of U/G cable Protective cover as per specification as given below. The concrete slab shall be machine made using semi dry concrete batching plant and cast in a fully 'vibro-pressed' machine with a high vibration frequency and Hydralic pressure of 40MT , sze of the slab shall be 480mm x250mmx50mm,(=+/- 2mm) &the concrete grade shall be m30 adhering to IS 456:2000 and shall have a minimum crushing strength of 30 n/mm2/(28days strength) when tested.

1968

135

265680

... More
Supply, storage, transportation to worksite 300 Sqmm,3 CORE Aluminium, XLPE insulated, flat strip armoured, 11KV (Earthed) Cable type A2xwy conforming I.S. 7098 PART 2 and carrying ISI MARK

944

2595

2449680

... More
3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 3LBS Extensible/Non Extensible Three (3) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU , modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.

2

585000

1170000

... More
Supply and erection testing and commissioning of Indoor type, Heat shrinkable, three phase, end terminating kit complete with sockets/plugs for 11KV (E) XLPE cable of size 3 crore 300sqmm for connecting RMU.

6

8840

53040

... More
Supply and Erection of H.S 11KV straight through joint 3 Core 240 to 400sqmm.

3

29559

88677

... More
Medium duty class B HDGI pipe for road/nullas crossing of nominal diameter 150 mm.

60

1681

100860

... More
HDGI flat of size 25mm x 5mm for earthing.

40

116

4640

... More
RCC Cable route marker (400 x 900 x 100mm) (as per CEE approved drawing, copy enclosed)

15

528

7920

... More
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size for repairing of drains.

6

6635

39810

... More
COST OF ERECTION

-

-

-

... More
Earthwork excavation in foundation trenches (not exceeding 1.5 mts in depth including opening of roads, chambers/pavements and soiling, ramming, levelling of bottoms, making bottom freed from stones including removing out the excavated soil/material as directed within a lead of 40mtrs (1.2 mtr depth X 0.5 mtrwidth X 920 mtr length in soft soil.

552

468

258336

... More
Filling up of available excavated earth (excluding rock/stones)in trenches, plinth,sides foundation etc in layer not exceeding 0.2mt depth con-solidating each deposited layer by ramming and watering.

297.36

120

35683.2

... More
Disposal of surplus excavated soil / material by mechanical transportation including loading and unloading, stacking/levelling as directed within a distance of 2500mts

169.68

125

21349.14

... More
supply and laying of U/G cable Protective cover as per specification as given below. The concrete slab shall be machine made using semi dry concrete batching plant and cast in a fully 'vibro-pressed' machine with a high vibration frequency and Hydralic pressure of 40MT , sze of the slab shall be 480mm x250mmx50mm,(=+/- 2mm) &the concrete grade shall be m30 adhering to IS 456:2000 and shall have a minimum crushing strength of 30 n/mm2/(28days strength) when tested.

1968

60

118080

... More
Supply, storage, transportation to worksite 300 Sqmm,3 CORE Aluminium, XLPE insulated, flat strip armoured, 11KV (Earthed) Cable type A2xwy conforming I.S. 7098 PART 2 and carrying ISI MARK

944

342

322848

... More
3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 3LBS Extensible/Non Extensible Three (3) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU , modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.

2

9720

19440

... More
RMU foundation works as per civil estimate

1

25703

25703.97

... More
Supply and erection testing and commissioning of Indoor type, Heat shrinkable, three phase, end terminating kit complete with sockets/plugs for 11KV (E) XLPE cable of size 3 crore 300sqmm for connecting RMU.

6

2548

15288

... More
Supply and Erection of H.S 11KV straight through joint 3 Core 240 to 400sqmm.

3

3713

11139

... More
Medium duty class B HDGI pipe for road/nullas crossing of nominal diameter 150 mm.

60

182

10920

... More
HDGI flat of size 25mm x 5mm for earthing.

40

48

1920

... More
RCC Cable route marker (400 x 900 x 100mm) (as per CEE approved drawing, copy enclosed)

15

256

3840

... More
Providing rubble packing for Laying of 11KV U/G cable by open trench method at road crossings

128.8

2211

284776.8

... More
B.S-V Work of Linking of 11KV Maria Rosa feeder from Maria Rosa RMU calangute emanating from 33/11KV GIS Calangute to 11KV Calangute feeder at Baga circle emanating from 33/11KV Nagao substation inorder to provide ring feed arrangement under the jurisdiction of S/D IV CALANGUTE.

-

-

-

... More
COST OF MATERIAL

-

-

-

... More
Sand for cushioning of HT underground cables.

120.6

2170

261702

... More
supply and laying of U/G cable Protective cover as per specification as given below. The concrete slab shall be machine made using semi dry concrete batching plant and cast in a fully 'vibro-pressed' machine with a high vibration frequency and Hydralic pressure of 40MT , sze of the slab shall be 480mm x250mmx50mm,(=+/- 2mm) &the concrete grade shall be m30 adhering to IS 456:2000 and shall have a minimum crushing strength of 30 n/mm2/(28days strength) when tested.

2792

135

376920

... More
Supply, storage, transportation to worksite 300 Sqmm, Aluminium,XLPE insulated,flat strip armoured, 11KV (Earthed) Cable type A2xwy conforming I.S. 7098 PART 2 and carrying ISI MARK

1340

2595

3477300

... More
Supply testing and commissioning of 11KV SF6 Type Ring Main 4 way RMU 2 LBS +2CB motorized Unit 50 hz, 350 MVA effectuveky earthed system. The unit shall comprise of I) 2 nos. of incomer switch of rating 630 A 12 kv triple pole double break operating in oil with ON/OFF and earth position. II) 2 Vaccum circuit breaker with electrical closing and tripping along with disconnector and earthing swicthwes SCADA compactible and base channe The unit shall be with cable boxes complete for 3 core 300 mm2 XLPE cable for feeder, following accessories shall be supplied (iii)Termination protection wing 3 sets terminal protector. (iv)Inter locking

1

950000

950000

... More
3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 3LBS Extensible/Non Extensible Three (3) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU , modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.

1

585000

585000

... More
Supply and erection testing and commissioning of Indoor type, Heat shrinkable, three phase, end terminating kit complete with sockets/plugs for 11KV (E) XLPE cable of size 3 crore 300sqmm for connecting RMU.

6

8840

53040

... More
Supply and Erection of H.S 11KV straight through joint 3 Core 240 to 400sqmm.

5

29559

147795

... More
Medium duty class B HDGI pipe for road/nullas crossing of nominal diameter 150 mm.

90

1681

151290

... More
HDGI flat of size 25mm x 5mm for earthing.

40

116

4640

... More
RCC Cable route marker (400 x 900 x 100mm) (as per CEE approved drawing, copy enclosed)

15

528

7920

... More
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size for repairing of drains.

6

6635

39810

... More
COST OF ERECTION

-

-

-

... More
Earthwork excavation in foundation trenches (not exceeding 1.5 mts in depth including opening of roads, chambers/pavements and soiling, ramming, levelling of bottoms, making bottom freed from stones including removing out the excavated soil/material as directed within a lead of 40mtrs (1.2 mtr depth X 0.5 mtrwidth X 1300 mtr length in soft soil.

804

468

376272

... More
Filling up of available excavated earth (excluding rock/stones)in trenches, plinth,sides foundation etc in layer not exceeding 0.2mt depth con-solidating each deposited layer by ramming and watering.

422.1

120

50652

... More
Disposal of surplus excavated soil / material by mechanical transportation including loading and unloading, stacking/levelling as directed within a distance of 2500mts

261.3

125

32876.77

... More
supply and laying of U/G cable Protective cover as per specification as given below. The concrete slab shall be machine made using semi dry concrete batching plant and cast in a fully 'vibro-pressed' machine with a high vibration frequency and Hydralic pressure of 40MT , sze of the slab shall be 480mm x250mmx50mm,(=+/- 2mm) &the concrete grade shall be m30 adhering to IS 456:2000 and shall have a minimum crushing strength of 30 n/mm2/(28days strength) when tested.

2792

60

167520

... More
Supply, storage, transportation to worksite 300 Sqmm, Aluminium,XLPE insulated,flat strip armoured, 11KV (Earthed) Cable type A2xwy conforming I.S. 7098 PART 2 and carrying ISI MARK

1340

342

458280

... More
Supply testing and commissioning of 11KV SF6 Type Ring Main 4 way RMU 2 LBS +2CB motorized Unit 50 hz, 350 MVA effectuveky earthed system. The unit shall comprise of I) 2 nos. of incomer switch of rating 630 A 12 kv triple pole double break operating in oil with ON/OFF and earth position. II) 2 Vaccum circuit breaker with electrical closing and tripping along with disconnector and earthing swicthwes SCADA compactible and base channe The unit shall be with cable boxes complete for 3 core 300 mm2 XLPE cable for feeder, following accessories shall be supplied (iii)Termination protection wing 3 sets terminal protector. (iv)Inter locking

1

9720

9720

... More
3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 3LBS Extensible/Non Extensible Three (3) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU , modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.

1

9720

9720

... More
RMU foundation works as per civil estimate

1

57924

57924.01

... More
Supply and erection testing and commissioning of Indoor type, Heat shrinkable, three phase, end terminating kit complete with sockets/plugs for 11KV (E) XLPE cable of size 3 crore 300sqmm for connecting RMU.

6

2548

15288

... More
Supply and Erection of H.S 11KV straight through joint 3 Core 240 to 400sqmm.

5

3713

18565

... More
Medium duty class B HDGI pipe for road/nullas crossing of nominal diameter 150 mm.

90

182

16380

... More
HDGI flat of size 25mm x 5mm for earthing.

40

48

1920

... More
RCC Cable route marker (400 x 900 x 100mm) (as per CEE approved drawing, copy enclosed)

15

256

3840

... More
Providing rubble packing for Laying of 11KV U/G cable by open trench method at road crossings

182

2211

402402

... More
B.S-VI Work of Linking of 11KV Mark memorial feeder from 10 villa calangute DEOS to 11KV Caculo feeder at Falcon emanating from 33/11KV GIS Calangute substation inorder to provide ring feed arrangement under the jurisdiction of S/D IV CALANGUTE.

-

-

-

... More
COST OF MATERIAL

-

-

-

... More
Sand for cushioning of HT underground cables.

172.8

2170

374976

... More
supply and laying of U/G cable Protective cover as per specification as given below. The concrete slab shall be machine made using semi dry concrete batching plant and cast in a fully 'vibro-pressed' machine with a high vibration frequency and Hydralic pressure of 40MT , sze of the slab shall be 480mm x250mmx50mm,(=+/- 2mm) &the concrete grade shall be m30 adhering to IS 456:2000 and shall have a minimum crushing strength of 30 n/mm2/(28days strength) when tested.

4000

135

540000

... More
Supply, storage, transportation to worksite 300 Sqmm, Aluminium,XLPE insulated, flat strip armoured, 11KV (Earthed) Cable type A2xwy conforming I.S. 7098 PART 2 and carrying ISI MARK

1920

2595

4982400

... More
Supply testing and commissioning of 11KV SF6 Type Ring Main 4 way RMU 2 LBS +2CB motorized Unit 50 hz, 350 MVA effectuveky earthed system. The unit shall comprise of I) 2 nos. of incomer switch of rating 630 A 12 kv triple pole double break operating in oil with ON/OFF and earth position. II) 2 Vaccum circuit breaker with electrical closing and tripping along with disconnector and earthing swicthwes SCADA compactible and base channe The unit shall be with cable boxes complete for 3 core 300 mm2 XLPE cable for feeder, following accessories shall be supplied (iii)Termination protection wing 3 sets terminal protector. (iv)Inter locking

2

950000

1900000

... More
3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 3LBS Extensible/Non Extensible Three (3) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU , modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.

1

585000

585000

... More
Supply and erection testing and commissioning of Indoor type, Heat shrinkable, three phase, end terminating kit complete with sockets/plugs for 11KV (E) XLPE cable of size 3 crore 300sqmm for connecting RMU.

6

8840

53040

... More
Supply and Erection of H.S 11KV straight through joint 3 Core 240 to 400sqmm.

5

29559

147795

... More
Medium duty class B HDGI pipe for road/nullas crossing of nominal diameter 150 mm.

95

1681

159695

... More
HDGI flat of size 25mm x 5mm for earthing.

40

116

4640

... More
RCC Cable route marker (400 x 900 x 100mm) (as per CEE approved drawing, copy enclosed)

15

528

7920

... More
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size for foundations.

6

6635

39810

... More
COST OF ERECTION

-

-

-

... More
Earthwork excavation in foundation trenches (not exceeding 1.5 mts in depth including opening of roads, chambers/pavements and soiling, ramming, levelling of bottoms, making bottom freed from stones including removing out the excavated soil/material as directed within a lead of 40mtrs (1.2 mtr depth X 0.5 mtrwidth X 1900 mtr length in soft soil.

1152

468

539136

... More
Filling up of available excavated earth (excluding rock/stones)in trenches, plinth,sides foundation etc in layer not exceeding 0.2mt depth con-solidating each deposited layer by ramming and watering.

604.8

120

72576

... More
Disposal of surplus excavated soil / material by mechanical transportation including loading and unloading, stacking/levelling as directed within a distance of 2500mts

374.4

125

47107.01

... More
supply and laying of U/G cable Protective cover as per specification as given below. The concrete slab shall be machine made using semi dry concrete batching plant and cast in a fully 'vibro-pressed' machine with a high vibration frequency and Hydralic pressure of 40MT , sze of the slab shall be 480mm x250mmx50mm,(=+/- 2mm) &the concrete grade shall be m30 adhering to IS 456:2000 and shall have a minimum crushing strength of 30 n/mm2/(28days strength) when tested.

4000

60

240000

... More
Supply, storage, transportation to worksite 300 Sqmm, Aluminium,XLPE insulated, flat strip armoured, 11KV (Earthed) Cable type A2xwy conforming I.S. 7098 PART 2 and carrying ISI MARK

1920

342

656640

... More
Supply testing and commissioning of 11KV SF6 Type Ring Main 4 way RMU 2 LBS +2CB motorized Unit 50 hz, 350 MVA effectuveky earthed system. The unit shall comprise of I) 2 nos. of incomer switch of rating 630 A 12 kv triple pole double break operating in oil with ON/OFF and earth position. II) 2 Vaccum circuit breaker with electrical closing and tripping along with disconnector and earthing swicthwes SCADA compactible and base channe The unit shall be with cable boxes complete for 3 core 300 mm2 XLPE cable for feeder, following accessories shall be supplied (iii)Termination protection wing 3 sets terminal protector. (iv)Inter locking

2

9720

19440

... More
RMU foundation works as per civil estimate

1

12840

12840.93

... More
3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 3LBS Extensible/Non Extensible Three (3) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU , modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.

1

9720

9720

... More
Supply and erection testing and commissioning of Indoor type, Heat shrinkable, three phase, end terminating kit complete with sockets/plugs for 11KV (E) XLPE cable of size 3 crore 300sqmm for connecting RMU.

6

2548

15288

... More
Supply and Erection of H.S 11KV straight through joint 3 Core 240 to 400sqmm.

5

3713

18565

... More
Medium duty class B HDGI pipe for road/nullas crossing of nominal diameter 150 mm.

95

182

17290

... More
HDGI flat of size 25mm x 5mm for earthing.

40

48

1920

... More
RCC Cable route marker (400 x 900 x 100mm) (as per CEE approved drawing, copy enclosed)

15

256

3840

... More
Providing rubble packing for Laying of 11KV U/G cable by open trench method at road crossings

266

2211

588126



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.