Electricity Department Tender
View complete overview of Goa Electricity Department Tender
Costs
EMD
₹ 1,14,616Document Cost
₹ 1,500Tender Fee
₹ 6,000
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_ED_14801_1Bid Award Id
ViewTender No
EE/Div-I/Tender-1(Gen)/6672 dt 04/03/2024Tender Authority
Electricity Department ViewPurchaser Address
-
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Back Filling of the available excavated earth (excluding rock) in trenches, plinth, sides, foundation etc. in layer work exceeding 0.2 mtr. depth consolidating each deposited layer by ramming and watering. (0.9*0.45*400)-FOR HT, (0.9*0.45*200)-FOR LT
243
-
-
Supplying and laying of sand.(0.2*0.45*400)-HT, (0.2*0.45*200)-LT
54
117180
2170
Supply of Warning tape
0.6
9000
15000
Supply, storage, transportation to work site, laying, testing and commissioning of 11KV,3 core x 300 mm2 XLPE HT cable excluding cable end termination.
400
935200
2338
Supply, storage, transportation to work site, laying, testing and commissioning of 1.1KV, 3.5 core, 240 sq.mm XLPE Aluminium armoured cable
200
339600
1698
Supply, storage, transportation to work site, laying, testing and commissioning of 11KV,3 core x 95 mm2 XLPE HT cable excluding cable end termination.
50
56350
1127
Supply of 11 Kv cable end termination kits indoor type, (Raychem make) suitable for 3 core X 300 mm2 cable XLPE.
5
44200
8840
Supply of 11 Kv cable end termination kits indoor type, (Raychem make) 3 core X 95 mm2 cable XLPE
7
47117
6731
Supply of heat shrinkable straight through jointing kit suitable for 3 C x 300 sq.mm XLPE cable.
3
88677
29559
Supply of H.S.11KV Termination kit outdoor 95 sqmm XLPE 3 core.
2
20304
10152
Supply of 11 KV, 630 A, RMU(SF -6), 2 LBS, 1 CB, suitable for usage on 11 Kv 50 Hz on effectively earthed system.
2
1130000
565000
Supply of 11 KV Metering cubicle including PT - 11KV/110V and CT of 12.5/5A capacity, tri-vector DLMS meter (Electronic) 3 phase 4 wire 5A
2
541266
270633
Supply of Earthing as per IS 3043/1966. including supply, erection, testing & comm. of HDGI pipe 8 ft long 40 mm dia class B, fabricated & perforated confirming to I.E. rules of 1956 including alternate layers Bentonite compound 25-50mm thick , salt & earth inclusive of earthwork excavation of size 0.50x0.50x2.5m, backfilling & spreading of excavated earth evenly to get required earth resistance as per enclosed specification
10
78580
7858
Supply of Underground cable protective cover as per specs. The concrete slab shall be machine made using semi dry concrete that is batched in a fully automatic PLC controlled concrete batching plant and cast in a fully automatic "Vibro-press" machine with a high vibration frequency and hydraulic presuure of 40 MT, the size of the slab shall be 480mm*250mm*50mm and the concrete grade shall be M30 Adhring to IS 456l:2000 and shall have a minimum crushing strength of 30 N/mm2 (28 days strength) when tested.
1146
154710
135
Supply of 315 KVA, 11/0.433 KV,3ph, Mineral oil immersed and naturally cooled outdoor type, copper wound Non-sealed transformer delta/star connected with additional neutral brought out on load side, temperature rise shoule not exceed 45 degree c by thermometer in oil and 50 degree C by the resistance method in winding at full load rating, using type-A winding insulation (Kraft paper) with HV tappping (with off load tap changer) off load +5 to -10 in steps of 2.5%,+5 to -10 in steps of 2.5%, having 7 number of tap positions with standard accessories complete with test certificate with losses below 1025 watts at 50% load, 3100 watts at 100% load as per IS:1180(Part1):2014 with necessary permissions of Electrical inspector, as per specification no SS-TR-NSL.
1
839390
839390
Supply of Outdoor, LV Main Switchboard for 400KVA Transformer centre made of CRCA sheet with PU painted and complete with all accessories and HDGI mounting channels.
1
300950
300950
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size for foundations. =RMU(3*3.5*0.25), Transformer=(2.5*2.5*0.25)
4.19
27800
6635
Centering and Shuttering including strutting, propping etc and removal of formwork. (Dimension of concrete*8)
33.5
18860
563
12mm cement plaster 1:4 (1 - cement: 4 - fine sand) for foundations. =RMU((3*3.5)+(3.5*0.25*2)+(3*0.25*2)). Transformer=((2.5*2.5)+(1.2*2.5*4))
32
7136
223
Supply of 250 mm dia RCC Pipe as per GSR 2020 (Roads) item nn 1909
30
24210
807
Supply of GI Pipe 150mm, class B
18
30258
1681
Supply of FRP fencing complete with gate as per specification
1
76667
76667
Supplying and Spreading of 40/20 mm Basaltic or granitic stone aggregate in the switch yard
45
54540
1212
Supply of 11Kv RCC Cable route marker (400 x 900 x 100mm)
10
5280
528
Supply of HDGI Structure material including channels/angles for fabrication of shades/ Enclosure for Metering cubicle/ RMU.
600
101400
169
Supply of Modem for automatic meter reading
1
6000
6000
ERECTION , TESTING and COMMISSIONING
-
-
-
Route Tracing of Existing cable
2
12202
6101
Earth work excavation in foundation trenches or drain including opening of roads, chamber, pavements and soiling, ramming, leveling of bottoms, making bottom free from stones including removing out the excavated soil/ material as directed. (1.1*0.45*400)-for HT, (1.1*0.45*200)-for LT
297
138996
468
Back Filling of the available excavated earth (excluding rock) in trenches, plinth, sides, foundation etc. in layer work exceeding 0.2 mtr. depth consolidating each deposited layer by ramming and watering. (0.9*0.45*400)-FOR HT, (0.9*0.45*200)-FOR LT
243
29160
120
Supplying and laying of sand.(0.2*0.45*400)-HT, (0.2*0.45*200)-LT
54
-
-
E,T&C of Warning tape
0.6
-
-
storage, transportation to work site, laying, testing and commissioning of 11KV,3 core x 300 mm2 XLPE HT cable excluding cable end termination.
400
136800
342
storage, transportation to work site, laying, testing and commissioning of 1.1KV, 3.5 core, 240 sq.mm XLPE Aluminium armoured cable
200
54400
272
storage, transportation to work site, laying, testing and commissioning of 11KV,3 core x 95 mm2 XLPE HT cable excluding cable end termination.
50
9950
199
E,T&C of 11 Kv cable end termination kits indoor type, (Raychem make) suitable for 3 core X 300 mm2 cable XLPE.
5
12740
2548
E,T&C of 11 Kv cable end termination kits indoor type, (Raychem make) 3 core X 95 mm2 cable XLPE
7
17766
2538
E,T&C of heat shrinkable straight through jointing kit suitable for 3 C x 300 sq.mm XLPE cable.
3
11139
3713
E,T&C of H.S.11KV Termination kit outdoor 95 sqmm XLPE 3 core.
2
5296
2648
E,T&C of 11 KV, 630 A, RMU(SF -6), 2 LBS, 1 CB, suitable for usage on 11 Kv 50 Hz on effectively earthed system.
2
19440
9720
E,T&C of 11 KV Metering cubicle including PT - 11KV/110V and CT of 12.5/5A capacity, tri-vector DLMS meter (Electronic) 3 phase 4 wire 5A
2
21250
10625
Providing,testing&commissioning of Earthing as per IS 3043/1966. including supply, erection, testing & comm. of HDGI pipe 8 ft long 40 mm dia class B, fabricated & perforated confirming to I.E. rules of 1956 including alternate layers Bentonite compound 25-50mm thick , salt & earth inclusive of earthwork excavation of size 0.50x0.50x2.5m, backfilling & spreading of excavated earth evenly to get required earth resistance as per enclosed specification
10
49070
4907
E,T&C of Underground cable protective cover as per specs. The concrete slab shall be machine made using semi dry concrete that is batched in a fully automatic PLC controlled concrete batching plant and cast in a fully automatic "Vibro-press" machine with a high vibration frequency and hydraulic presuure of 40 MT, the size of the slab shall be 480mm*250mm*50mm and the concrete grade shall be M30 Adhring to IS 456l:2000 and shall have a minimum crushing strength of 30 N/mm2 (28 days strength) when tested.
1146
68760
60
E,T&C of 315 KVA, 11/0.433 KV,3ph, Mineral oil immersed and naturally cooled outdoor type, copper wound Non-sealed transformer delta/star connected with additional neutral brought out on load side, temperature rise shoule not exceed 45 degree c by thermometer in oil and 50 degree C by the resistance method in winding at full load rating, using type-A winding insulation (Kraft paper) with HV tappping (with off load tap changer) off load +5 to -10 in steps of 2.5%,+5 to -10 in steps of 2.5%, having 7 number of tap positions with standard accessories complete with test certificate with losses below 1025 watts at 50% load, 3100 watts at 100% load as per IS:1180(Part1):2014 with necessary permissions of Electrical inspector, as per specification no SS-TR-NSL.
1
-
-
E,T&C of Outdoor, LV Main Switchboard for 400KVA Transformer centre made of CRCA sheet with PU painted and complete with all accessories and HDGI mounting channels.
1
12500
12500
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size for foundations. =RMU(3*3.5*0.25), Transformer=(2.5*2.5*0.25)
4.19
-
-
Centering and Shuttering including strutting, propping etc and removal of formwork. (Dimension of concrete*8)
33.5
-
-
12mm cement plaster 1:4 (1 - cement: 4 - fine sand) for foundations. =RMU((3*3.5)+(3.5*0.25*2)+(3*0.25*2)). Transformer=((2.5*2.5)+(1.2*2.5*4))
32
-
-
E,T&C of 250 mm dia RCC Pipe as per GSR 2020 (Roads) item nn 1909
30
7620
254
E,T&C of GI Pipe 150mm, class B
18
3276
182
E,T&C of FRP fencing complete with gate as per specification
1
35000
35000
Supplying and Spreading of 40/20 mm Basaltic or granitic stone aggregate in the switch yard
45
-
-
E,T&C of 11Kv RCC Cable route marker (400 x 900 x 100mm)
10
2560
256
E,T&C of HDGI Structure material including channels/angles for fabrication of shades/ Enclosure for Metering cubicle/ RMU.
600
28200
47
E,T&C of Modem for automatic meter reading
1
-
-
Evaluation Notes How It Works ?