Electricity Department Tender

View complete overview of Goa Electricity Department Tender

Electricity Department Tender

Works
Energy, Oil and Gas
Eprocure
Opening Date26 Dec 2024
Closing Date29 Jan 2025
Tender Amount₹ 2,71,76,685 
Notes
Download

Costs

  • EMD

    ₹ 5,43,534
  • Document Cost

    ₹ 1,500
  • Tender Fee

    ₹ 6,000

Summary

Work Of Shifting Of Old 11 Kv Control Room And Supply, Erection, Testing And Commissioning Of Additional Newly Installed 10 Mva Power Transformer Along With Other Required Accessories At 33/11 Kv Colony Sub-station At Curti Under Sub Division-i, Divx

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Work of shifting of old 11 KV Control Room and Supply, Erection, Testing and Commissioning of additional newly installed 10 MVA Power Transformer along with other required accessories at 33/11 KV Colony Sub-Station at Curti under Sub Division-I, DivisionX
Work of shifting of old 11 KV Control Room and Supply, Erection, Testing and Commissioning of additional newly installed 10 MVA Power Transformer along with other required accessories at 33/11 KV Colony Sub-Station at Curti under Sub Division-I, Division
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of 12KV, 630A (BB - 1250A), 25KA 3 Secs, 3 phase, indoor type VCB, with spring type operating mechanism, mounted on rack out type trolley, along with 3 Nos of 12 KV CT, 3 Core, 400-200-/5-5 Amps, LV Compartment with Breaker Control panel consisting of Voltmeter, Ammeter, MFM, BCPU NUMERICAL relays 61850 prtocol with master and Trip Circuit supervision, LED type indication lamps, TTBs, Annunciation, 3 phase, 4 wire, DLMS energy meter with 4G modem along with software updation in the back end system for data integration with MDM. Complete as per Technical Specification. (11KV OUTGOING FEEDERS)

4

1200000

4800000

... More
Supply of 3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 3LBS :- Extensible/Non Extensible Three (3) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU , modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU. Auxiliary PT as per specification shall be provided in RMU.

11

720000

7920000

... More
Supply of 11KV, 3 core 300 sq.mm A2XFY Aluminium Armoured XLPE Cable through conventional open trenching method in any type of soil including hard laterite.

1000

2595

2595000

... More
Supply of 11KV, 3 core 400 sq.mm A2XFY Aluminium Armoured XLPE Cable through conventional open trenching method in any type of soil including hard laterite.

200

3150

630000

... More
Supply of 11KV 3 phase indoor terminating kit to be used with cables - 300sq.mm.

34

8840

300560

... More
Supply of 11KV 3 phase indoor terminating kit to be used with cables - 400sq.mm.

4

8840

35360

... More
Supply of 36 KV, 1250 Amps, 25 KA, 3 Pole, Outdoor type VCB, with spring type operation mechanism along with G.I. support structure, marsahalling box,Pad type terminal connectors suitable for ACSR Wolf conductor and all required accessories, (Make:- Crompton Greaves Ltd/Areva/shreem Electric Ltd/MEI/Jyoti/Schneider) complete as per technical specifications.(For Incoming line and for power Transformer)

2

413125

826250

... More
Supply of 33 KV, 400-200/5-5A, 25KA, single phase, copper wound, C.T. having two secondaries, along with terminal connectors and marshalling box, complete with all accessories as per technical specification. (For Incoming line )

3

65923

197769

... More
Supply of 33 KV, 200/5-5-1A, 25KA, single phase, copper wound, C.T. having two secondaries, along with terminal connectors and marshalling box, complete with all accessories as per technical specification. (For Power Transfomer )

3

65923

197769

... More
Supply of 33 KV/3/110 V/3, 100 VA copper wound Potential Transformer having one secondary, along with terminal connectors and one marshalling box, complete with all accessories as per technical specification.(Bus and Power Transformer)

6

43033

258199.98

... More
Supply of 36 KV, 630 A, 25 KA , 3 PH, 3 pin type , Gang operated,horizontal operation type double break GOAB Switch/isolators along with support insulators, operating mechanism along with drum contacts , base channel, down pipe, arcing horns, terminal connectors and all required accessories, complete as per technical specifications with earth switch(For Incoming line and for power Transformer)

6

94569

567414

... More
Supply of ACSR Wolf conductor for bus bar & jumpers, droppers /terminations.

0.5

225000

112500

... More
Supply of Terminal connector for connecting 33 KV circuit breaker to single ACSR Wolf conductor horizontal approach

15

742

11130

... More
Supply of Terminal connector for connecting LA, CT, PT, Power Transformer to single ACSR Wolf conductor horizontal approach

39

939

36621

... More
Supply of Terminal connector for isolator to single ACSR Wolf conductor horizontal as well as vertical approach

30

742

22260

... More
Supply of Tee connector suitable for ACSR Wolf conductor through & single ACSR Wolf conductor tee off.

15

439

6585

... More
Supply of 11 KV Disc insulators, 70 KN ball and socket type, type ‘A’ porcelain brown glazed duly cemented at factory with MCI socket cap, forged steel ball pin and supplied with Phosphor bronze “W” split pin as per IS 731-1971 as amended upto date. Minimum failing load. Pin ball diameter 16 mm. Minimum Creepage distance 320 mm. Ferrous parts shall be galvanized as per relevant IS. Insulator shall be marked as per IS. Acceptance tests and routine tests shall be carried out as per IS by the manufacturer and test results shall be furnished by the manufacturer before supply of materials.

135

1336

180360

... More
Supply of Metal parts for Disc insulators 70 KN 3-bolted type hardware fitting 70KN suitable for 11KV ball and socket type disc insulators of 18mm pin, failing load of 70KN. Conform to IS-2486 Part 1-1993, 2486 Part 2-1989 as amended upto date.

45

1550

69750

... More
Supply of 33 KV Pin Insulators. 33 KV brown glazed porcelain pin insulator with minimum failing load of 10 KN and the Minimum creepage distance of 840 mm conforming to IS 731-1971 as amended upto date. Insulators shall be marked and packed as per IS. Routine tests and acceptance tests as per IS shall be carried at the manufacturers works and test results shall be furnished before supply of materials.

12

1696

20352

... More
Supply of G.I. Pin for 33 KV Pin Insulators. Forged G. I. Pin conforming to IS 2486 part 1 & 2 as amended upto date suitable for 33 KV porcelain pin insulators conforming to IS: 731/71 as amended upto date. G. I. pin shall be supplied along with one suitable G. I. hexagonal nut and G. I. spring washer. Pin shall conform to reference L230N fig. 6 of IS 2486 part 2. Dimension ‘X’ in said fig. shall be 150 mm (screwed 100 mm). Minimum failing load of pin shall be 10 KN. G. I. pins and nuts shall be hot dip galvanized as per IS: 2629/66 as amended up to date. The washers shall be electro galvanized. Acceptance tests and Routine tests shall be carried out at the manufacturers works and test reports shall be furnished before supply of materials.

12

546

6552

... More
Supply of Lightning/Surge Arrestors 30 KV station type (10 KA): Type: Gapless Type, Applicable standards: IEC 60099-4 & IS: 3070-1993 (part-3). No of units per arrester: Single unit of 30kV, Highest system voltage: 36kV, Normal system voltage: 33kV, System earthing: Solidly earth system, Rated Voltage in kV (RMS): 30kV, Nominal discharge current(8/20 μsecond wave): 10kA, Long duration discharge class: Discharge class-II, Maximum Continuous Operating Voltage (kV): 25Vrms, Insulation withstand test voltages. a) One Min. Power Frequency withstand Voltage(Dry&Wet): 70 kVrms. Max. residual voltage for discharge current of 8/20μ seconds. a) 5000 Amps: 85kVpeak. b) 10000 Amps: 90kVpeak. c) 20000 Amps: 100kVpeak. Maximum steep current Impulse Residual Voltage at 10kA of 1 μ second front. Time: 100kVpeak. Maximum Switching Impulse Residual voltage 30/60μ second at 500 Amps: 80kVpeak (at 500 A), 70kVpeak(at 250A). Minimum energy discharge capability: 6kJ/kV (OD test - 2 shots). Mounting flange dimensions: 3 holes θ14 on PCD.

4

26453

105812

... More
Supply of Lightning/Surge Arrestors 9 KV station type, 10 KA: Type: Gapless Type, Applicable standards: IEC 60099-4 & IS: 3070-1993 (part-3). No of units per arrester: Single unit of 9kV, Highest system voltage: 12kV, Normal system voltage: 11kV, System earthing: Solidly earth system, Rated Voltage in kV (RMS): 9kV, Nominal discharge current(8/20 μsecond wave): 10kA, Long duration discharge class: Discharge class-II, Maximum Continuous Operating Voltage (kV): 7.65Vrms. Insulation withstand test voltages. a) One Min. Power Frequency withstand Voltage(Dry&Wet): 28kVrms. b) Lightning Impluse Withstand Voltage: 75 Vpeak. Max. residual voltage for discharge current of 8/20μ seconds. a) 5000 Amps: 25kVpeak. b) 10000 Amps: 27kVpeak. c) 20000 Amps: 30kVpeak. Maximum steep current Impluse Residual Voltage at 10kA of I μ second front Time: 30kVpeak. Maximum Switching Impluse Residual voltage 30/60μ second at 500 Amps: 24kVpeak. Minimum energy discharge capability: 5kJ/kV (OD test - 2 shots). Mounting flange dimensions: 3 slots on PCD.

2

7808

15616

... More
Supply of Earthing complete with Class B, 100 mm dia nominal bore, 3000 mm long pipe earth electrodes with test Connection links having welded flat of size 50 x 6 mm for connecting earth strip, RCC chamber, CI cover hinged to CI frame, other accessories as per Technical specs, alongwith required quantity of charcoal, salt etc or Bentonite to be buried below ground and to be connected with earth mat of MS Flat. i.e. Chemical Earthing.

22

11644

256168

... More
Supply of GI Flat 25 x 5 mm.

300

116

34800

... More
Supply of GI Flat 50 x 6 mm.

300

208

62400

... More
Supply of Copper Strip 50x6 mm(2.69kgs) for connections CT, VCB, LA, TR etc.

40

2882

115280

... More
Supply of 4C X 2.5 Sq.mm control cable Multistrand copper conductor, PVC insulated , Armoured, along with cable glands and lugs complete as per technical specification

800

242

193600

... More
Supply of 12C X 2.5 Sq.mm control cable Multistrand copper conductor, PVC insulated , Armoured, along with cable glands and lugs complete as per technical specification

500

575

287500

... More
Supply of 2C X 2.5 Sq.mm control cable Multistrand copper conductor, PVC insulated , Armoured, along with cable glands and lugs complete as per technical specification

600

119

71400

... More
Supply of HDGI Nut bolts etc

120

228

27360

... More
Supply of HDGI Steel structure materials in single sections including cutting, hoisting, fabrication, consisting of HDGI R.S joist of size 250 x 125 mm, 16 mtr long - 1 Nos (for 33KV bay) along with suitable HDGI nut bolts, washers, packing pieces, welding cleats, etc (Weignt per Mts = 37.30 Kgs)

596.8

169

100859.2

... More
Supply of HDGI Steel structure materials in single sections including cutting, hoisting, fabrication, consisting of HDGI R.S joist of size 150 x 75 mm for 33 KV structure 5 mtr long - 10 Nos (for 33KV bay for mounting Isolators, PT, CT LA ets) alongwith suitable HDGI nut bolts, washers, packing pieces, welding cleats, etc (Weignt per Mts = 15.00 Kgs)

750

169

126750

... More
Supply of HDGI Steel structure materials in single sections including cutting, hoisting, fabrication, consisting of ISMC 100 x 50 HDGI channels for 33 KV structure 5 mts long - 20 Nos (for 33 KV Bay) along with suitable HDGI nut bolts, washers, cross arm clamps, stay clamps & other accessories complete as per Technical specifications and site requirement. (Weignt per Mts = 7.80 Kgs)

780

169

131820

... More
Supply of 11KV grade 2.5mm thick insulating Rubber mat of size 1 mtr. Wide and 2.5 mm thick

21

2076

43596

... More
Supply and filling of Sand in plinth uner floors , trenches including waterin ,ramming consolidating ,dressing complete. (0.2 x 2.4 x 100)

48

2170

104160

... More
Supply and laying of underground cable protective cover as per specification as given below: The concrete slab shall be machine made using semidry concrete that is batched in a fully autoumatic PLC controlled concrete batching plant and cast in a fully automatic " Vibro - Press" Machine with a high vibration frequency and hydraulic pressure of 40 MT, the size of the slab shall be 480 mm X 250 mm x 50mm. (+/- 2 mm) and the concrete grade shall be M 30 adhering to IS 456: 2000 and shall have a minimum crushing strength of 30 N/mm2 ( 28 days strength) when tested. (100/0.48 = 208), (2.4/0.25 = 9.6), (208 x 9.6 = 1996.8)

1997

135

269595

... More
Supply of Cable Route marker

20

352

7040

... More
Supply and laying of Warning tape.

1

15000

15000

... More
Supply of Bricks class design 75 kg/cm2 (1st class wire cut) for Cable dividers

150

9

1425

... More
Erection Cost

-

-

-

... More
Erection of 33KV Control & Relay for 6.3/10/20 MVA Power Transformer consisting of electronic trivector energy meter, Voltmeter, Ammeter, EF, OC, Differential, SEF relays, Master trip relay, Indication lamps, Semaphore, Annunciation Panel Complete etc. (33 KV CONTROL & RELAY PANEL FOR 10 MVA POWER TRANSFORMER)

1

50000

50000

... More
Erection of 12KV, 1250A (BB - 1250A), 25KA 3 Secs, 3 phase, indoor type VCB, with spring type operating mechanism, mounted on rack out type trolley, along with 3 Nos of 12 KV CT, 3 Core, 800-400-/5-5-1 Amps, 11KV/110/v3/110v3 V Line Potential Transformer, LV Compartment with Breaker Control panel consisting of Voltmeter, Ammeter, MFM, BCPU NUMERICAL relays 61850 prtocol with master and Trip Circuit supervision, LED type indication lamps, TTBs, Annunciation, 3 phase, 4 wire, DLMS energy meter with 4G modem along with software updation in the back end system for data integration with MDM. Complete as per Technical Specification. (11KV INCOMER)

2

45000

90000

... More
Erection of 12KV, 630A (BB - 1250A), 25KA 3 Secs, 3 phase, indoor type VCB, with spring type operating mechanism, mounted on rack out type trolley, along with 3 Nos of 12 KV CT, 3 Core, 400-200-/5-5 Amps, LV Compartment with Breaker Control panel consisting of Voltmeter, Ammeter, MFM, BCPU NUMERICAL relays 61850 prtocol with master and Trip Circuit supervision, LED type indication lamps, TTBs, Annunciation, 3 phase, 4 wire, DLMS energy meter with 4G modem along with software updation in the back end system for data integration with MDM. Complete as per Technical Specification. (11KV OUTGOING FEEDERS)

4

40000

160000

... More
Erection of 3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 3LBS :- Extensible/Non Extensible Three (3) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU , modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU. Auxiliary PT as per specification shall be provided in RMU.

11

9720

106920

... More
Erection of 11KV, 3 core 300 sq.mm A2XFY Aluminium Armoured XLPE Cable through conventional open trenching method in any type of soil including hard laterite.

1000

342

342000

... More
Erection of 11KV, 3 core 400 sq.mm A2XFY Aluminium Armoured XLPE Cable through conventional open trenching method in any type of soil including hard laterite.

200

342

68400

... More
Erection of 11KV 3 phase indoor terminating kit to be used with cables - 300sq.mm.

34

2548

86632

... More
Erection of 11KV 3 phase indoor terminating kit to be used with cables - 400sq.mm.

4

2548

10192

... More
Erection of 36 KV, 1250 Amps, 25 KA, 3 Pole, Outdoor type VCB, with spring type operation mechanism along with G.I. support structure, marsahalling box,Pad type terminal connectors suitable for ACSR Wolf conductor and all required accessories, (Make:- Crompton Greaves Ltd/Areva/shreem Electric Ltd/MEI/Jyoti/Schneider) complete as per technical specifications.(For Incoming line and for power Transformer)

2

16900

33800

... More
Erection of 33 KV, 400-200/5-5A, 25KA, single phase, copper wound, C.T. having two secondaries, along with terminal connectors and marshalling box, complete with all accessories as per technical specification. (For Incoming line )

3

3883

11649

... More
Erection of 33 KV, 200/5-5-1A, 25KA, single phase, copper wound, C.T. having two secondaries, along with terminal connectors and marshalling box, complete with all accessories as per technical specification. (For Power Transfomer )

3

3883

11649

... More
Erection of 33 KV/3/110 V/3, 100 VA copper wound Potential Transformer having one secondary, along with terminal connectors and one marshalling box, complete with all accessories as per technical specification.(Bus and Power Transformer)

6

3119

18714

... More
Erection of 36 KV, 630 A, 25 KA , 3 PH, 3 pin type , Gang operated,horizontal operation type double break GOAB Switch/isolators along with support insulators, operating mechanism along with drum contacts , base channel, down pipe, arcing horns, terminal connectors and all required accessories, complete as per technical specifications with earth switch(For Incoming line and for power Transformer)

6

9283

55698

... More
Erection of ACSR Wolf conductor for bus bar & jumpers, droppers /terminations.

0.5

13784

6892

... More
Erection of 11 KV Disc insulators, 70 KN ball and socket type, type ‘A’ porcelain brown glazed duly cemented at factory with MCI socket cap, forged steel ball pin and supplied with Phosphor bronze “W” split pin as per IS 731-1971 as amended upto date. Minimum failing load. Pin ball diameter 16 mm. Minimum Creepage distance 320 mm. Ferrous parts shall be galvanized as per relevant IS. Insulator shall be marked as per IS. Acceptance tests and routine tests shall be carried out as per IS by the manufacturer and test results shall be furnished by the manufacturer before supply of materials.

135

184

24840

... More
Erection of Metal parts for Disc insulators 70 KN 3-bolted type hardware fitting 70KN suitable for 11KV ball and socket type disc insulators of 18mm pin, failing load of 70KN. Conform to IS-2486 Part 1-1993, 2486 Part 2-1989 as amended upto date.

45

191

8595

... More
Erection of 33 KV Pin Insulators. 33 KV brown glazed porcelain pin insulator with minimum failing load of 10 KN and the Minimum creepage distance of 840 mm conforming to IS 731-1971 as amended upto date. Insulators shall be marked and packed as per IS. Routine tests and acceptance tests as per IS shall be carried at the manufacturers works and test results shall be furnished before supply of materials.

12

156

1872

... More
Erection of G.I. Pin for 33 KV Pin Insulators. Forged G. I. Pin conforming to IS 2486 part 1 & 2 as amended upto date suitable for 33 KV porcelain pin insulators conforming to IS: 731/71 as amended upto date. G. I. pin shall be supplied along with one suitable G. I. hexagonal nut and G. I. spring washer. Pin shall conform to reference L230N fig. 6 of IS 2486 part 2. Dimension ‘X’ in said fig. shall be 150 mm (screwed 100 mm). Minimum failing load of pin shall be 10 KN. G. I. pins and nuts shall be hot dip galvanized as per IS: 2629/66 as amended up to date. The washers shall be electro galvanized. Acceptance tests and Routine tests shall be carried out at the manufacturers works and test reports shall be furnished before supply of materials.

12

152

1824

... More
Erection of Lightning/Surge Arrestors 30 KV station type (10 KA): Type: Gapless Type, Applicable standards: IEC 60099-4 & IS: 3070-1993 (part-3). No of units per arrester: Single unit of 30kV, Highest system voltage: 36kV, Normal system voltage: 33kV, System earthing: Solidly earth system, Rated Voltage in kV (RMS): 30kV, Nominal discharge current(8/20 μsecond wave): 10kA, Long duration discharge class: Discharge class-II, Maximum Continuous Operating Voltage (kV): 25Vrms, Insulation withstand test voltages. a) One Min. Power Frequency withstand Voltage(Dry&Wet): 70 kVrms. Max. residual voltage for discharge current of 8/20μ seconds. a) 5000 Amps: 85kVpeak. b) 10000 Amps: 90kVpeak. c) 20000 Amps: 100kVpeak. Maximum steep current Impulse Residual Voltage at 10kA of 1 μ second front. Time: 100kVpeak. Maximum Switching Impulse Residual voltage 30/60μ second at 500 Amps: 80kVpeak (at 500 A), 70kVpeak(at 250A). Minimum energy discharge capability: 6kJ/kV (OD test - 2 shots). Mounting flange dimensions: 3 holes θ14 on PCD.

4

1484

5936

... More
Erection of Lightning/Surge Arrestors 9 KV station type, 10 KA: Type: Gapless Type, Applicable standards: IEC 60099-4 & IS: 3070-1993 (part-3). No of units per arrester: Single unit of 9kV, Highest system voltage: 12kV, Normal system voltage: 11kV, System earthing: Solidly earth system, Rated Voltage in kV (RMS): 9kV, Nominal discharge current(8/20 μsecond wave): 10kA, Long duration discharge class: Discharge class-II, Maximum Continuous Operating Voltage (kV): 7.65Vrms. Insulation withstand test voltages. a) One Min. Power Frequency withstand Voltage(Dry&Wet): 28kVrms. b) Lightning Impluse Withstand Voltage: 75 Vpeak. Max. residual voltage for discharge current of 8/20μ seconds. a) 5000 Amps: 25kVpeak. b) 10000 Amps: 27kVpeak. c) 20000 Amps: 30kVpeak. Maximum steep current Impluse Residual Voltage at 10kA of I μ second front Time: 30kVpeak. Maximum Switching Impluse Residual voltage 30/60μ second at 500 Amps: 24kVpeak. Minimum energy discharge capability: 5kJ/kV (OD test - 2 shots). Mounting flange dimensions: 3 slots on PCD.

2

882

1764

... More
Erection of Earthing complete with Class B, 100 mm dia nominal bore, 3000 mm long pipe earth electrodes with test Connection links having welded flat of size 50 x 6 mm for connecting earth strip, RCC chamber, CI cover hinged to CI frame, other accessories as per Technical specs, alongwith required quantity of charcoal, salt etc or Bentonite to be buried below ground and to be connected with earth mat of MS Flat. i.e. Chemical Earthing.

22

6248

137456

... More
Erection of GI Flat 25 x 5 mm.

300

48

14400

... More
Erection of GI Flat 50 x 6 mm.

300

48

14400

... More
Erection of Copper Strip 50x6 mm(2.69kgs) for connections CT, VCB, LA, TR etc.

40

21

840

... More
Erection of 4C X 2.5 Sq.mm control cable Multistrand copper conductor, PVC insulated , Armoured, along with cable glands and lugs complete as per technical specification

800

49

39200

... More
Erection of 12C X 2.5 Sq.mm control cable Multistrand copper conductor, PVC insulated , Armoured, along with cable glands and lugs complete as per technical specification

500

74

37000

... More
Erection of 2C X 2.5 Sq.mm control cable Multistrand copper conductor, PVC insulated , Armoured, along with cable glands and lugs complete as per technical specification

600

42

25200

... More
Erection of HDGI Nut bolts etc

120

30

3600

... More
Erection of HDGI Steel structure materials in single sections including cutting, hoisting, fabrication, consisting of HDGI R.S joist of size 250 x 125 mm, 16 mtr long - 1 Nos (for 33KV bay) along with suitable HDGI nut bolts, washers, packing pieces, welding cleats, etc (Weignt per Mts = 37.30 Kgs)

596.8

47

28049.6

... More
Erection of HDGI Steel structure materials in single sections including cutting, hoisting, fabrication, consisting of HDGI R.S joist of size 150 x 75 mm for 33 KV structure 5 mtr long - 10 Nos (for 33KV bay for mounting Isolators, PT, CT LA ets) alongwith suitable HDGI nut bolts, washers, packing pieces, welding cleats, etc (Weignt per Mts = 15.00 Kgs)

750

47

35250

... More
Erection of HDGI Steel structure materials in single sections including cutting, hoisting, fabrication, consisting of ISMC 100 x 50 HDGI channels for 33 KV structure 5 mts long - 20 Nos (for 33 KV Bay) along with suitable HDGI nut bolts, washers, cross arm clamps, stay clamps & other accessories complete as per Technical specifications and site requirement. (Weignt per Mts = 7.80 Kgs)

780

47

36660

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in all types of Ordinary rock including all types of laterite rock, blasting prohibited. (1.1 x 2.4 x 100)

264

639

168696

... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge. (0.9 x 2.4 x 100)

216

245

52920

... More
Disposal of extra excavated soil (0.2 x 2.4 x 100).

48

125

6039.36

... More
Erection of underground cable protective cover as per specification as given below: The concrete slab shall be machine made using semidry concrete that is batched in a fully autoumatic PLC controlled concrete batching plant and cast in a fully automatic " Vibro - Press" Machine with a high vibration frequency and hydraulic pressure of 40 MT, the size of the slab shall be 480 mm X 250 mm x 50mm. (+/- 2 mm) and the concrete grade shall be M 30 adhering to IS 456: 2000 and shall have a minimum crushing strength of 30 N/mm2 ( 28 days strength) when tested. (100/0.48 = 208), (2.4/0.25 = 9.6), (208 x 9.6 = 1996.8)

1997

60

119820

... More
Erection of Cable Route marker

20

183

3660

... More
Removing and Re-erection of existing 11KV OUTGOING FEEDERS Panel of 33/11KV Colony S/S Complete

4

60000

240000

... More
Removing of existing 11KV INCOMER Panel from old 11 KV Control room and 33/11KV Colony S/S Complete

3

22500

67500

... More
Removing of existing 11KV OUTGOING FEEDERS Panel from old 11 KV Control room Complete

8

20000

160000

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : b) All types of Ordinary rock including all types of laterite rock, blasting prohibited

21.44

639

13700.16

... More
Rubble packing with hard laterite stones unders floors including watering, ramming and consolidating etc. in pipeline trenches and other foundations complete.

3.23

2211

7141.53

... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge.

3.21

245

786.45

... More
Providing & laying cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded granitic or basaltic stone aggrt. 20 mm. nominal size) excluding cost of centering, shuttering and finishing in: a) All works upto plinth level

3.12

6810

21247.2

... More
Providing & laying cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded granitic or basaltic stone aggrt. 20 mm. nominal size) excluding cost of centering, shuttering and finishing in: a) All works upto plinth level

1.71

6325

10815.75

... More
Providing and laying in position (1:11/2:3) Reinforced cement conrete excluding the cost of centering, shuttering, finishing and reinfrocement (1 cement: 1½ coarse sand:3 graded stone agg 20mm nominal size). a) All works upto plinth level

1.85

7178

13279.3

... More
b) in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and structs etc. upto floor five level

1.3

8034

10444.2

... More
Centering & shuttering including Strutting, Propping & removal of forms for i) Foundations, Footings, Bases for columns

17.88

407

7277.16

... More
ii) Vertical surfaces such as retaining walls, return walls, Partitions, walls (any thickness) including attached Pilasters, Buttresses, Plinth and string courses, Fillets and the like

25.5

479

12214.5

... More
iii) Columns, Piers, Pillars, Aburments, Posts and struts (square rectangle polygon in plan)

8.58

598

5130.84

... More
Providing TMT steel reinforcement bars of (SAIL, TATA. VIZAG, JSW Steel Ltd.) (Confirming to IS 1786 of 1986) for RCC work (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in all the floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member.

200

105

21000

... More
18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand) and top layer 6mm thick with cement plaster 1: 3 (1 cement : 3 coarse sand) finished with sponge.

2.94

329

967.26



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.