Electricity Department Tender

View complete overview of Goa Electricity Department Tender

Electricity Department Tender

Works
Civil And Construction
Eprocure
Opening Date3 Jul 2024
Closing Date23 Jul 2024
Tender Amount₹ 2,09,90,284 
Notes
Download

Costs

  • EMD

    ₹ 4,19,806
  • Document Cost

    ₹ 1,500
  • Tender Fee

    ₹ 6,000

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of 3 WAY RMU,11KV,630A,21KA 3Sec, SF6 Outdoor RMU-2LBS+ 1CBExtensible/Non-Extensible two (2) Motor operated load break switches (LBSs) with Manual operated earthing switches in SG6 nad One (1) vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1no`s per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery charger shall be provided in RMU.

2

1130000

565000

... More
Supply of 11KV, 3 phase, Indoor type, heat shrinkable end termination kit complete, for 11 KV XLPE cable of size 3 x 300sq.mm including sockets/lugs/connectors etc. for connecting RMU for main section side of approved make .

4

35360

8840

... More
Supply of 11KV, 3 phase, outdoor type, heat shrinkable end termination kit complete, for 11 KV XLPE cable of size 3 x 300sq.mm including sockets/lugs/connectors etc. for connecting RMU for main section side of approved make .

2

23334

11667

... More
Supply of 11KV 3 phase Indoor terminating kit complete, for 11 KV XLPE cable of size 3 x 120sq.mm including sockets/lugs/connectors etc. for connecting RMU for main section side of approved make.

2

15746

7873

... More
Supply of 11KV 3 phase outdoor terminating kit complete, for 11 KV XLPE cable of size 3 x 120sq.mm including sockets/lugs/connectors etc. for connecting Transformer for main section side of approved make.

2

21862

10931

... More
Supply of Outdoor, LV Main Switchboard for 200KVA Transformer centre made out of CRCA sheet with PU painted and complete with all accessories, HDGI mounting/base channels of approved make .

2

458208

229104

... More
Supply of 1 core, 300sq.mm, Al conductor XLPE insulated 1.1KV grade unarmoured power cable and carrying ISI MARK & approved make. (from transformer to LV distribution board)

88

41976

477

... More
Supply of 3½ core 120 sq.mm. aluminium, XLPE insulated armoured 1.1KV power cable and carrying ISI MARK & of approved make. The work includes termination with Aluminum lugs & providing glands at LVSB.

775

707575

913

... More
Supply of 3½ core 240 sq.mm. aluminium, XLPE insulated armoured 1.1KV power cable and carrying ISI MARK & of approved make. The work includes termination with Aluminum lugs & providing glands at LVSB.

471

799758

1698

... More
Supply of 4 core 16 sq.mm. aluminium, XLPE insulated armoured 1.1KV power cable and carrying ISI MARK & of approved make. The work includes termination with Aluminum lugs & providing glands at LVSB.

5160

1026840

199

... More
Supply of 4-way Feeder Pillar, TP&N, 3 phase, 415V, 2 nos. of 315Amps incomings, 4 nos. of 200Amps outgoing rating type suitable for outdoor installation made out of CRCA sheet with PU painted complete with all accesories and HDGI mounting channels as per enclosed specifications & of approved make.

2

365774

182887

... More
Supply of 48-Way Distribution Service Pillar, 3 phase, 415V, 100A MCCB incoming; 12 nos. of 16 A, SP MCBs, Distribution Service Pillar suitable for outdoor installation made out of of CRCA sheet with PU painted complete with all accessories, HDGI mounting channels, clamps, ties, nut bolts etc. of approved make.

5

513760

102752

... More
Supply of HDGI, 8.0mts long Octagonal tapered Poles made out of 4mm thick plate ( broder base --155 A/R) and having the following provisions and of approved make:- a. 4 nos. of J type M20 x 750mm long (UNF Thread -100mm) foundation bolts of grade EN 8. b. Base Plate steel of size 225 x 225 mm, thickness 16 mm. broder Base (155 A/R) c. 1.5 mts long single arm brackets HDGI, 3.25mm thick for mounting the fixture of outer diamter 48mm. d. 50mm dia HDPE pipe, PN-4, P-63 Grdae 2.65 mm for cable entry and exit (2 runs) with proper termination for LT cable.

74

1652420

22330

... More
Supply of HDGI, 8.0mts long Octagonal tapered Poles made out of 4mm thick plate( broder base --155 A/R) and having the following provisionsand of approved make :- a. 4 nos. of J type M20 x 750mm long (UNF Thread -100mm) foundation bolts b. Base Plate steel of size 225 x 225 mm, thickness 16 mm.( broder base --155 A/R) c. 1.5 mts long four arm brackets HDGI, 3.25mm thick for mounting the fixture of outer diamter 50mm. d. 50mm dia HDPE pipe, PN-4, P-63 Grdae 2.65 mm for cable entry and exit (2 runs)with proper termination for LT cable.

2

51040

25520

... More
Supply of HDGI, 6.0mts long Octagonal Poles made out of 4mm thick plate ( broder base --155 A/R)and having the following provisionsand of approved make :- a. 4 nos. of J type M20 x 750mm long (UNF Thread -100mm) foundation bolts of grade EN8 b. Base Plate steel of size 225 x 225 mm, thickness 16 mm.( broder base --155 A/R) c. 1.5 mts long single arm brackets HDGI, 3.25mm thick for mounting the fixture of outer diamter 50mm d. 50mm dia HDPE pipe, PN-4, P-63 Grdae 2.65 mm for cable entry and exit (2 runs) with proper termination for LT cable.

6

106980

17830

... More
Supply of 50 W LED light fittings, of appproved make following specifications:- a) Rated Voltage : 230V AC, Power consumption 50W Voltage range :140 V AC to 280 V AC b) Over voltage, Over current, Internal SurgeProtection-YES c)LED Life Span:50,000 Hrs d) White color LED, Glass type:Toughhned glass, Luminaries body: Aluminium casting e)Lumen efficacy shall be equal to or greater than 125 lumen/watt

88

519200

5900

... More
Supply of PVC Insulated, multistanded copper cable of size 3-core x 2.5sq. mm from juction box to fixture including termination of cable with lugs for LED fixtures. The cable shall carry concerned ISI mark & approved make.

820

124640

152

... More
Supply of XLPE Armoured cable 4C x 16 sq.mm, 1.1KV Grade from one streetlight pole to another & Service connections including termination of cable with lugs . The cable shall carry concerned ISI mark & approved make.

3280

652720

199

... More
Supply of Street Light Service Pillar made out of CRCA sheet with PU painted complete with 4 pole MCCB,3 pole MCBs, TP Contactors, Electonic/Digital cum mechanical dual Timer, connectors etc. complete as per enclosed specifications & approved make.

2

98948

49474

... More
Supply of 3½ core 50 sq.mm. aluminium, XLPE insulated armoured 1.1KV power cable including termination of cable with lugs/glands and with ISI MARK& approved make.

100

43600

436

... More
Supply & Installation, testing & commissioning of Automatic Meter Reading Unit

2

12000

6000

... More
Supply of Cable route Markers (for entire HT/LT cable route length ) as per NIT drawing.

51

26928

528

... More
Supply and laying of fine river sand of approved quality for cushioning of HT/ LT underground cables laid by conventional Open Trenching Method.

567.09

1230585

2170

... More
Supply of RCC protective covers of size 600mm length x 250mm width x 50mm thick bearing load of 135 Kg & covered with earth/ sand upo depth of 0.15 mtrs confirming to IS 1256-1967 at non road crossing.

15233

1934591

127

... More
Supply of wire cut brick for 11kv cable sepration

2440

23180

9.5

... More
Supply of G.I. earthing pipe, 2500mm long, 40mm nominal dia, class B, perforated for RMU's, Transformers, LVSB's, Feeder Pillar's, Service Pillar's , Streetlight Pillar's, Streetlight Poles . The pit shall be filled with homogenous mixture of 20Kgs of Charcoal, 20Kgs of salt and sand /soil with Brick masonary Chambers The work includes excavation, backfilling & spreading of excavated surplace earth evenly at RMU's, LV Switchboard etc.

114

504792

4428

... More
Supply of HDGI flat of size 25mm x 5mm for earthing of RMU's, Transformers, LVSB's, Feeder Pillar's, Service Pillar's , Streetlight Pillar's, Streetlight Poles

570

66120

116

... More
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size for foundations of RMU's, Transformers, LVSB's, Feeder Pillar's, Service Pillar's , Streetlight Pillar's, cement concrete for laying foundation for octagonal poles including the cost of centering, shuttering and muffing 0.5 m above ground and of diameter 0.5 m (Pit dimensions : 0.5 X 0.5 X 1.2 mts.)

41.67

231476

5555

... More
Providing of Centering and shuttering including struttings, propping etc. and removal of formwork for a) Foundations, footings, bases of columns and mass concrete for Feeder Pillar's, Service Pillar's , Streetlight Pillar's, Streetlight Poles

337

189731

563

... More
Providing of 12 mm cement plaster 1:4 ( 1 cement: 4 fine sand) for foundations of Feeder Pillar's, Service Pillar's , Streetlight Pillar's

33.64

4945

147

... More
Providing FRP Fencing complete with Gate around every distribution sub-station containing RMU, one distribution transformer and one LV switchboard including danger plate (Size  4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

2

153334

76667

... More
Masonary work for Transformer's plinth using hard laterite stones

2.7

20023

7416

... More
Supply of RCC Hume Pipe 150mm dia with required no. of collars, for road crossing.

769

243773

317

... More
Supply of G.I. Pipe of class B, 50mm dia after inserting service cable at road crossing & restoring the same to the original condition as per MMC/ PWD requirement.

100

42400

424

... More
Supply of GI Pipe 150mm, class B for Nala/drainage/bridge crossing

24

40344

1681

... More
Erection

-

-

-

... More
Laying, testing & commissioning of 11KV, 3 core, 300 sq.mm. aluminium, XLPE insulated, flat armoured, 11 KV (Earthed) Cable, type A2XFY of approved make conforming I.S. 7098 PART 2 and carrying ISI MARK through open trench method in any type of soil including hard laterite.

1066

364572

342

... More
Laying, testing & commisioning of 11KV, 3 core 120 sq.mm aluminium, XLPE insulated, flat armoured, 11 KV (Earthed) Cable, type A2XFY of approved make conforming I.S. 7098 PART 2 and carrying ISI MARK through conventional open trenching method in any type of soil including hard laterite.

16

3456

216

... More
Erection, testing & commissioning of 3 WAY RMU,11KV,630A,21KA 3Sec, SF6 Outdoor RMU-2LBS+ 1CBExtensible/Non-Extensible two (2) Motor operated load break switches (LBSs) with Manual operated earthing switches in SG6 nad One (1) vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1no`s per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery charger shall be provided in RMU.

2

19440

9720

... More
Erection, testing & commissioning of 11KV, 3 phase, Indoor type, heat shrinkable end termination kit complete, for 11 KV XLPE cable of size 3 x 300sq.mm including sockets/lugs/connectors etc. for connecting RMU for main section side of approved make .

4

10192

2548

... More
Erection,testing & commissioning of 11KV, 3 phase, outdoor type, heat shrinkable end termination kit complete, for 11 KV XLPE cable of size 3 x 300sq.mm including sockets/lugs/connectors etc. for connecting RMU for main section side of approved make .

2

5436

2718

... More
Erection, testing & commissioning of 11KV 3 phase Indoor terminating kit complete, for 11 KV XLPE cable of size 3 x 120sq.mm including sockets/lugs/connectors etc. for connecting RMU for main section side of approved make.

2

5096

2548

... More
Erection, testing & commissioning of 11KV 3 phase outdoor terminating kit complete, for 11 KV XLPE cable of size 3 x 120sq.mm including sockets/lugs/connectors etc. for connecting Transformer for main section side of approved make.

2

5296

2648

... More
Removal and erection of of 3 phase, 50Hz, 11/0.433KV, 200KVA, Distribution Transformer complete with Level -II losses, copper winding with Bi-metallic terminal connectors Energy efficiency -Level-II as per IS:1180(Part-I):2014 suitable for outdoor use and for plinth mounting of approved make .

2

46914

23457

... More
Erection, testing & commissioning of Outdoor, LV Main Switchboard for 200KVA Transformer centre made out of CRCA sheet with PU painted and complete with all accessories, HDGI mounting/base channels of approved make .

2

25000

12500

... More
Laying, testing & commisioning of 1 core, 300sq.mm, Al conductor XLPE insulated 1.1KV grade unarmoured power cable and carrying ISI MARK & approved make. (from transformer to LV distribution board)

88

19184

218

... More
Laying, testing & commisioning of 3½ core 120 sq.mm. aluminium, XLPE insulated armoured 1.1KV power cable and carrying ISI MARK & of approved make. The work includes termination with Aluminum lugs & providing glands at LVSB.

775

136400

176

... More
Laying, testing & commisioning of 3½ core 240 sq.mm. aluminium, XLPE insulated armoured 1.1KV power cable and carrying ISI MARK & of approved make. The work includes termination with Aluminum lugs & providing glands at LVSB.

471

128112

272

... More
Laying, testing & commisioning of 4 core 16 sq.mm. aluminium, XLPE insulated armoured 1.1KV power cable and carrying ISI MARK & of approved make. The work includes termination with Aluminum lugs & providing glands at LVSB.

5160

412800

80

... More
Erection, testing & commissioning of 4-way Feeder Pillar, TP&N, 3 phase, 415V, 2 nos. of 315Amps incomings, 4 nos. of 200Amps outgoing rating type suitable for outdoor installation made out of CRCA sheet with PU painted complete with all accesories and HDGI mounting channels as per enclosed specifications & of approved make.

2

9632

4816

... More
Erection, testing & commissioning of 48-Way Distribution Service Pillar, 3 phase, 415V, 100A MCCB incoming; 12 nos. of 16 A, SP MCBs, Distribution Service Pillar suitable for outdoor installation made out of of CRCA sheet with PU painted complete with all accessories, HDGI mounting channels, clamps, ties, nut bolts etc. of approved make.

5

22205

4441

... More
Erection, testing & commissioning of HDGI, 8.0mts long Octagonal tapered Poles made out of 4mm thick plate ( broder base --155 A/R) and having the following provisions and of approved make:- a. 4 nos. of J type M20 x 750mm long (UNF Thread -100mm) foundation bolts of grade EN 8. b. Base Plate steel of size 225 x 225 mm, thickness 16 mm. broder Base (155 A/R) c. 1.5 mts long single arm brackets HDGI, 3.25mm thick for mounting the fixture of outer diamter 48mm. d. 50mm dia HDPE pipe, PN-4, P-63 Grdae 2.65 mm for cable entry and exit (2 runs) with proper termination for LT cable.

74

387834

5241

... More
Erection, testing & commissioning of HDGI, 8.0mts long Octagonal tapered Poles made out of 4mm thick plate( broder base --155 A/R) and having the following provisionsand of approved make :- a. 4 nos. of J type M20 x 750mm long (UNF Thread -100mm) foundation bolts b. Base Plate steel of size 225 x 225 mm, thickness 16 mm.( broder base --155 A/R) c. 1.5 mts long four arm brackets HDGI, 3.25mm thick for mounting the fixture of outer diamter 50mm. d. 50mm dia HDPE pipe, PN-4, P-63 Grdae 2.65 mm for cable entry and exit (2 runs)with proper termination for LT cable.

2

10482

5241

... More
Erection, testing & commissioning of HDGI, 6.0mts long Octagonal Poles made out of 4mm thick plate ( broder base --155 A/R)and having the following provisionsand of approved make :- a. 4 nos. of J type M20 x 750mm long (UNF Thread -100mm) foundation bolts of grade EN8 b. Base Plate steel of size 225 x 225 mm, thickness 16 mm.( broder base --155 A/R) c. 1.5 mts long single arm brackets HDGI, 3.25mm thick for mounting the fixture of outer diamter 50mm d. 50mm dia HDPE pipe, PN-4, P-63 Grdae 2.65 mm for cable entry and exit (2 runs) with proper termination for LT cable.

6

28272

4712

... More
Erection, testing & commissioning of 50 W LED light fittings, of appproved make following specifications:- a) Rated Voltage : 230V AC, Power consumption 50W Voltage range :140 V AC to 280 V AC b) Over voltage, Over current, Internal SurgeProtection-YES c)LED Life Span:50,000 Hrs d) White color LED, Glass type:Toughhned glass, Luminaries body: Aluminium casting e)Lumen efficacy shall be equal to or greater than 125 lumen/watt

88

35200

400

... More
Laying, testing & commissioning of PVC Insulated, multistanded copper cable of size 3-core x 2.5sq. mm from juction box to fixture including termination of cable with lugs for LED fixtures. The cable shall carry concerned ISI mark & approved make.

820

39360

48

... More
Laying, testing & commissioning of XLPE Armoured cable 4C x 16 sq.mm, 1.1KV Grade from one streetlight pole to another & Service connections including termination of cable with lugs . The cable shall carry concerned ISI mark & approved make.

3280

262400

80

... More
Erection, testing & commissioning of Street Light Service Pillar made out of CRCA sheet with PU painted complete with 4 pole MCCB,3 pole MCBs, TP Contactors, Electonic/Digital cum mechanical dual Timer, connectors etc. complete as per enclosed specifications & approved make.

2

7892

3946

... More
Laying of 3½ core 50 sq.mm. aluminium, XLPE insulated armoured 1.1KV power cable including termination of cable with lugs/glands and with ISI MARK& approved make.

100

12100

121

... More
Erection of Cable route Markers (for entire HT/LT cable route length ) as per NIT drawing.

51

13056

256

... More
Excavation in any type of soil including hard laterite soil by mechanical means( hydraulic excavator)/manual means for laying of HT/LT cables of various sizes including excavation for equipment foundations i.e for including excavation for equipment foundations i.e for RMU's, Transformers, LVSB's, Feeder Pillar, Service Pillar Octagonal Poles etc. including getting out the excavated soil and disposal of surplus excavated soil.

4494.62

2103482

468

... More
Refilling of excavated soil in the foundations, trenches etc. with avialable excavated earth in layers not exceeding 20 cm depth, cosolidating each layer by ramming and watering lead upto 50 M and all lifts and disposal of surplus earth in cable trenches and foundations of equipments.

3500.54

420064

120

... More
Erection, testing & commissioning of G.I. earthing pipe, 2500mm long, 40mm nominal dia, class B, perforated for RMU's, Transformers, LVSB's, Feeder Pillar's, Service Pillar's , Streetlight Pillar's, Streetlight Poles . The pit shall be filled with homogenous mixture of 20Kgs of Charcoal, 20Kgs of salt and sand /soil with Brick masonary Chambers The work includes excavation, backfilling & spreading of excavated surplace earth evenly at RMU's, LV Switchboard etc.

114

303810

2665

... More
Erection, testing & commissioning of HDGI flat of size 25mm x 5mm for earthing of RMU's, Transformers, LVSB's, Feeder Pillar's, Service Pillar's , Streetlight Pillar's, Streetlight Poles

570

27360

48

... More
Providing FRP Fencing complete with Gate around every distribution sub-station containing RMU, one distribution transformer and one LV switchboard including danger plate (Size  4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6

2

70000

35000

... More
Laying of RCC Hume Pipe 150mm dia with required no. of collars, for road crossing.

769

116119

151

... More
Laying of G.I. Pipe of class B, 50mm dia after inserting service cable at road crossing & restoring the same to the original condition as per MMC/ PWD requirement.

100

4300

43

... More
Laying of GI Pipe 150mm, class B for Nala/drainage/bridge crossing

24

4368

182

... More
Carrying out detailed physical survey of the area including detailed GPS survey which includes indicating and marking location of other utilities if any, furnishing of optimum and economical route and design for layong of LT, XLPE cables of various size and accessories, including plotting on the scaled land base map of size 1:1000 indicating all features and submitting drilling profile indicating proposed plan for open trenching,road,nullah,culvet, over bridge, rail crossing, or any other special crossing. The work shall include digging of trial pits at suitable intervals and re-instatement of dug-up area of trial pits. The detailed documents as well as the write-up shall be furnished in 02 nos. of hard copies and soft copies for approval.Upon approval fresh 06 Nos. of hard copies alongwith a soft copy shall be furnished duly corrected. On completion, the contractor has to submit final survey map with longitude and latitude of each every item with other details for asset mapping.

4.65

69750

15000

... More
Removing of 11KV Disc Insulator with metal parts 45KN

6

996

166

... More
Removing of 11 kv V-shape cross arm

6

1014

169

... More
Removing of 11 KV Pin insulator with G.I. pins

12

912

76

... More
RCC poles 11 mtrs long

6

25800

4300

... More
RCC poles 7.5 mtrs long

51

94069

1844.5

... More
L.T. pin insulator with G.I. pin

185

16002

86.5

... More
L.T. Shackle insulator with metal parts

171

17784

104

... More
M.S. Distribution box complete 200 AMP

2

4687

2343.5

... More
30W LED Fixture complete.(42+82)+(8*30) * 51

51

9282

182

... More
Removing of 11 KV GOAB switch 200A

2

3971

1985.5

... More
Removing of 11 KV HG fuse set 200A

2

3368

1684

... More
Removing of ACSR 'WEASEL' CONDUCTOR.

1.08

3839

3555

... More
Removing of 4 pin LT 'X' arm "Channel' with clamps & Nut Bolts

66

10758

163

... More
Removing of 2 pin LT 'X' arm "Channel' with clamps & Nut Bolts

53

7870

148.5

... More
Removing of ACC ANT Conductor

4.84

16054

3317

... More
Removing of ACC GNAT Conductor

5.88

18178

3091.5



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.