Electricity Department Tender

View complete overview of Goa Electricity Department Tender

Electricity Department Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date4 Oct 2024
Closing Date22 Oct 2024
Tender Amount₹ 10,31,909 
Notes
Download

Costs

  • EMD

    ₹ 20,638
  • Document Cost

    ₹ 500
  • Tender Fee

    ₹ 2,064

Summary

Tender For The Work Of Enhancement Of 2 Nos. Of Dtcs From 100 Kva To 200kva At Bhairelwada, Keri And Rmd Keri For Aps To 2 Nos. Of 3 Phase Ltd S. Cs. Under The Jurisdiction Of S. O. Parye And Sankhali Under Sub Div Ii Sankhali.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply & erection of LT/11KV Stay set complete 11Mts long RCC pole

2

9227

4613.57

... More
Supply & Erection of ACSR Conductor Hard drawn stranded aluminium conductor with galvanized steel wire reinforced WEASEL 6/1/2.59 (nominal aluminium area 30 Sq.mm.) (139 amp max at 45 °C) for line

0.3

12030

40100

... More
Supply & Erection of Earthing complete with chamber as per drg/ No. CEE/E-830. Each earthing should consist as follows a) 40 mm. Dia 2.5 mtr long, class B GI pipe 1 No. b)HDGI nut bolts, clamps 1 set, c)Brick masonary-0.108 Cu.mts d) PVC pipe 50mm dia- 0.2mtr e) Salt-20 Kgs f) Charcoal-20 Kgs g) Excavation-0.864 Cu. Mtr h) refilling-0.74 Cu.mtr .

6

16380

2730

... More
Supply & Stringing of XPLE insulated single core unarmoured cable 50 mm2 for DP earthing.

55

7425

135

... More
Supply & Erection of MS Distribution box along with MCCB 400 A, Bus bar made out of Aluminium strips 40 x 10 mm, kit kat fuses for 4 feeder arrangement

1

63140

63140

... More
Supply & Stringing of XLPE 1.1KV Armored single core unarmoured cable 300 mm²

48

26640

555

... More
Supply & stringing of XLPE 1.1KV 3 & 1/2 XLPE Armoured cable 120 mm²

24

22680

945

... More
Supply & Erection of Enamelled danger boards 11000 Volts ,250mm x 200mmm

2

496

248

... More
Supply & Erection of FRP Fencing complete with Gate as epr specification for distribution transformer (size 4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5)Cu.m.x12nos Each ratio 1;3;6

1

76667

76667

... More
Supply & Erection of DTC metering unit

1

25688

25688

... More
Supply & Erection of 4g Modem for automatic reading

1

6000

6000

... More
Painting of Pole Numbers

2

208

104.33

... More
Supply & Erection of 4pin X arm channel with clamps & nut bolt of 9 mtr RCC pole

2

2932

1466.2

... More
Supply & Erection of LT Shackle insulator with metal parts

10

3720

372

... More
Supply & Erection of ANT conductor

0.54

32670

60500

... More
Supply & Erection of GNAT Conductor

0.6

18600

31000

... More
Supply & erection of LT/11KV Stay set complete 9 Mts long RCC pole

2

8733

4366.54

... More
Cost of Erection

-

-

-

... More
Supply & Erection of 11 KV rated voltange GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming to IS: 9921-Part 1 to V as amended up to date and detailed specification eclosed herewith. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufacturer of the insulators and have minimum 320 mm creepage distance and AB switchs contacts shall be of copper/ copper alloy. The AB switch shall be of following current rating: 200 A

1

3971

3971

... More
Supply & Erection of 11 KV , 200 A Horn gap fuse unit (Set of three) shall be as per enclosed drg No. CEE/E-786. Revision 3 and detailed specifications enclosed herewith.

1

3368

3368

... More
Supply & Erection of 9 KV, 5 KA nominal discharge current metal oxide gapless distribution class Lightning arrestor conforming to IEC-600994-4 and IS: 3070 part 3 1993 as amended upto date suitable for 11 KV 50 HZ effectively earthed neutral system with necessary mounting arragements and connector suitable to connect ASCR conductor upto overall diameter 12.30 mm

3

522

174

... More
Supply & Erection of HDGI structure material. trasformer centre DP consist of HDGI structure material as follows: a) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for incoming line & installation of disc insulators b) GI channel ISMC75x40x7.3mm 2.75mtrs long 2 pieces for GOAB switch c) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for HG fuses d) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for installation of lightening arrestor e) GI channel ISMC 100x50x7.3mm 2.75 mtrs long 2 pieces for installation of Trasformer f) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for side support of trasformer g) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 4 pieces for installation of any other items h) GI channel ISMC 100x40x7.3mm 0.52 mtrs long 2 pieces for installation of Transformer base channel

260

12220

47

... More
Supply & Erection of 200KVA 11/0.433KV 3 phase outdoor type ,oil immeresed Aluminium wound level II distribution trasnfromers

1

15638

15638

... More
Supply & erection of LT/11KV Stay set complete 11Mts long RCC pole

2

5072

2536.34

... More
Supply & Erection of ACSR Conductor Hard drawn stranded aluminium conductor with galvanized steel wire reinforced WEASEL 6/1/2.59 (nominal aluminium area 30 Sq.mm.) (139 amp max at 45 °C) for line

0.3

3300

11000

... More
Supply & Erection of Earthing complete with chamber as per drg/ No. CEE/E-830. Each earthing should consist as follows a) 40 mm. Dia 2.5 mtr long, class B GI pipe 1 No. b)HDGI nut bolts, clamps 1 set, c)Brick masonary-0.108 Cu.mts d) PVC pipe 50mm dia- 0.2mtr e) Salt-20 Kgs f) Charcoal-20 Kgs g) Excavation-0.864 Cu. Mtr h) refilling-0.74 Cu.mtr .

6

14664

2444

... More
Supply & Stringing of XPLE insulated single core unarmoured cable 50 mm2 for DP earthing.

55

3080

56

... More
Supply & Erection of MS Distribution box along with MCCB 400 A, Bus bar made out of Aluminium strips 40 x 10 mm, kit kat fuses for 4 feeder arrangement

1

8795

8795

... More
Supply & Stringing of XLPE 1.1KV Armored single core unarmoured cable 300 mm²

48

12720

265

... More
Supply & stringing of XLPE 1.1KV 3 & 1/2 XLPE Armoured cable 120 mm²

24

4224

176

... More
Supply & Erection of Enamelled danger boards 11000 Volts ,250mm x 200mmm

2

114

57

... More
Supply & Erection of Aluminium crimping Lugs shall as amended upto date. Lugs shall be made of aluminium of grade suitable for aluminium cable fo sizes 300 Sq.mm.

8

808

101

... More
Supply & Erection of Aluminium crimping Lugs shall as amended upto date. Lugs shall be made of aluminium suitable for aluminium cable fo sizes 120 Sq.mm.

6

528

88

... More
Supply & Erection of Aluminium crimping Lugs . Lugs shall be made of aluminium of grade IE of suitable for aluminium cable fo sizes 95 Sq.mm.

2

130

65

... More
Supply & Erection of Aluminium crimping Lugs as amended upto date. Lugs shall be made of aluminium of grade IE of IS: 5082/1969 suitable for aluminium cable fo sizes50 Sq.mm.

55

2805

51

... More
Supply & Erection of FRP Fencing complete with Gate as epr specification for distribution transformer (size 4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5)Cu.m.x12nos Each ratio 1;3;6

1

35000

35000

... More
Supply & Erection of DTC metering unit

1

1072

1072

... More
Cement concreting 1 : 2:4

2.5

13887

5555

... More
Removing of 11KV GOAB switch 200 A, 3 Pole DP AB Switch

1

1985

1985.5

... More
Removing of 11KV 200 A H.G Fuse unit

1

1684

1684

... More
Removing of 9kv, 5KA lightening Arrestor pole mounted.

3

261

87

... More
Removing of HDGI structural material

260

6110

23.5

... More
Removing of MS Distribution Box

1

4397

4397.5

... More
Removing of XLPE 1.1KV 3 & 1/2 c cable 120 sq. mm²

10

880

88

... More
Removing of XLPE 1.1KV 3 & 1/2 c cable 95 sq. mm²

24

1788

74.5

... More
Removing of 100 KVA trasnformer

1

5508

5508.5

... More
Erection of 9 mtr RCC pole

2

11800

5900

... More
Supply & Erection of 4pin X arm channel with clamps & nut bolt of 9 mtr RCC pole

2

636

318

... More
Supply & Erection of 2 pin X arm channel with clamps & nut bolt of 9mtr RCC pole

2

578

289

... More
Supply & Erection of LT Shackle insulator with metal parts

10

2080

208

... More
Removing of 7.5mtr RCC pole

1

2600

2600

... More
Removing of 4pin X arm channel with clamps & nut bolt of 7.5 mtr RCC pole

1

152

152.5

... More
Removing of 2 pin X arm channel with clamps & nut bolt of 7.5mtr RCC pole

1

138

138

... More
Supply & Erection of ANT conductor

0.54

5562

10300

... More
Supply & Erection of GNAT Conductor

0.6

5460

9100

... More
Removing of ANT Conductor

0.24

1236

5150

... More
Removing of GNAT Conductor

0.24

1092

4550

... More
Supply & erection of LT/11KV Stay set complete 9 Mts long RCC pole

2

4931

2465.88

... More
Sub- Estimate under Normal development scheme for Enhancement of 100 KVA DTC RMD Keri to 200KVA RMD Keri for APS to 1 nos. of 3 phase LTD Service connection for Total connected load of 28.04 KW of 1) MRs.Suman Ra,mnath Gawas ,Ghoeli No.01 Keri for load 13.96 KW 2) Mr.Krishna Vishnu Dalvi ,Ghoteli No.01 for load 5.22 Kw & 3) Chandrakant Narayan Gawas ,Ghoeli No.01,Keri for a load 8.86 Kw under the jurisdiction of Section Office Sakhali, Sub div-II ( R) Sakhali, Div:- V, Bicholim.

-

-

-

... More
Cost of Material

-

-

-

... More
Supply & Erection of HDGI structure material. trasformer centre DP consist of HDGI structure material as follows: a) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for incoming line & installation of disc insulators b) GI channel ISMC75x40x7.3mm 2.75mtrs long 2 pieces for GOAB switch c) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for HG fuses d) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for installation of lightening arrestor e) GI channel ISMC 100x50x7.3mm 2.75 mtrs long 2 pieces for installation of Trasformer f) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for side support of trasformer g) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 4 pieces for installation of any other items h) GI channel ISMC 100x40x7.3mm 0.52 mtrs long 2 pieces for installation of Transformer base channel

260

43940

169

... More
Supply & erection of LT/11KV Stay set complete 9 Mts long RCC pole

3

13099

4366.54

... More
Supply & Erection of HDG L.T. 4 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 9 mts long RCC pole

3

4398

1466.2

... More
Supply & Erection of LT brown glazed shackle Insulator of size 100 mm x 115 mm Minimum failing load shall be 16 KN with GI hardware suitable for LT shackle insulator of size 100 x 115 mm Hardware or fittinge for 2 GI strips, 2 GI bolts and 2 nuts with spring washers.

15

5580

372

... More
Supply & Erection of ACSR Conductor Hard drawn stranded aluminium conductor with galvanized steel wire reinforced WEASEL 6/1/2.59 (nominal aluminium area 30 Sq.mm.) (139 amp max at 45 °C) for line

0.3

12030

40100

... More
Supply & Erection of Earthing complete with chamber as per drg/ No. CEE/E-830. Each earthing should consist as follows a) 40 mm. Dia 2.5 mtr long, class B GI pipe 1 No. b)HDGI nut bolts, clamps 1 set, c)Brick masonary-0.108 Cu.mts d) PVC pipe 50mm dia- 0.2mtr e) Salt-20 Kgs f) Charcoal-20 Kgs g) Excavation-0.864 Cu. Mtr h) refilling-0.74 Cu.mtr .

6

16380

2730

... More
Supply & Stringing of XPLE insulated single core unarmoured cable 50 mm2 for DP earthing.

55

7425

135

... More
Supply & Stringing of AA"ANT" conductor

0.5

30250

60500

... More
Supply & stringing of AA"GNAT" conductor

0.23

7130

31000

... More
Supply & Erection of MS Distribution box along with MCCB 400 A, Bus bar made out of Aluminium strips 40 x 10 mm, kit kat fuses for 4 feeder arrangement

1

63140

63140

... More
Supply & Stringing of XLPE 1.1KV Armored single core unarmoured cable 300 mm²

48

26640

555

... More
Supply & stringing of XLPE 1.1KV 3 & 1/2 XLPE Armoured cable 120 mm²

36

34020

945

... More
Supply & Erection of Enamelled danger boards 11000 Volts ,250mm x 200mmm

2

496

248

... More
Supply & Erection of DTC metering unit

1

25688

25688

... More
Supply & Erection of 4g Modem for automatic reading

1

6000

6000

... More
Cost of Erection

-

-

-

... More
Supply & Erection of RCC pole 9 mtr RCC pole

1

5900

5900

... More
Supply & Erection of 11 KV rated voltange GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming to IS: 9921-Part 1 to V as amended up to date and detailed specification eclosed herewith. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufacturer of the insulators and have minimum 320 mm creepage distance and AB switchs contacts shall be of copper/ copper alloy. The AB switch shall be of following current rating: 200 A

1

3971

3971

... More
Supply & Erection of 11 KV , 200 A Horn gap fuse unit (Set of three) shall be as per enclosed drg No. CEE/E-786. Revision 3 and detailed specifications enclosed herewith.

1

3368

3368

... More
Supply & Erection of 9 KV, 5 KA nominal discharge current metal oxide gapless distribution class Lightning arrestor conforming to IEC-600994-4 and IS: 3070 part 3 1993 as amended upto date suitable for 11 KV 50 HZ effectively earthed neutral system with necessary mounting arragements and connector suitable to connect ASCR conductor upto overall diameter 12.30 mm

3

522

174

... More
Supply & Erection of HDGI structure material. trasformer centre DP consist of HDGI structure material as follows: a) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for incoming line & installation of disc insulators b) GI channel ISMC75x40x7.3mm 2.75mtrs long 2 pieces for GOAB switch c) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for HG fuses d) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for installation of lightening arrestor e) GI channel ISMC 100x50x7.3mm 2.75 mtrs long 2 pieces for installation of Trasformer f) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for side support of trasformer g) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 4 pieces for installation of any other items h) GI channel ISMC 100x40x7.3mm 0.52 mtrs long 2 pieces for installation of Transformer base channel

260

12220

47

... More
Supply & Erection of 200KVA 11/0.433KV 3 phase outdoor type ,oil immeresed Aluminium wound level II distribution trasnfromers

1

15638

15638

... More
Supply & erection of LT/11KV Stay set complete 9 Mts long RCC pole

3

7397

2465.88

... More
Supply & Erection of HDG L.T. 4 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 9 mts long RCC pole

3

954

318

... More
Supply & Erection of HDG L.T. 2 pin cross arm Channel type as above with HDG clamps & HDG nut bolts etc for 9 mts long RCC pole

2

578

289

... More
Supply & Erection of LT brown glazed shackle Insulator of size 100 mm x 115 mm Minimum failing load shall be 16 KN with GI hardware suitable for LT shackle insulator of size 100 x 115 mm Hardware or fittinge for 2 GI strips, 2 GI bolts and 2 nuts with spring washers.

15

3120

208

... More
Supply & Erection of ACSR Conductor Hard drawn stranded aluminium conductor with galvanized steel wire reinforced WEASEL 6/1/2.59 (nominal aluminium area 30 Sq.mm.) (139 amp max at 45 °C) for line

0.3

3300

11000

... More
Supply & Erection of Earthing complete with chamber as per drg/ No. CEE/E-830. Each earthing should consist as follows a) 40 mm. Dia 2.5 mtr long, class B GI pipe 1 No. b)HDGI nut bolts, clamps 1 set, c)Brick masonary-0.108 Cu.mts d) PVC pipe 50mm dia- 0.2mtr e) Salt-20 Kgs f) Charcoal-20 Kgs g) Excavation-0.864 Cu. Mtr h) refilling-0.74 Cu.mtr .

6

14664

2444

... More
Supply & Stringing of XPLE insulated single core unarmoured cable 50 mm2 for DP earthing.

55

3080

56

... More
Supply & Stringing of AA"ANT" conductor

0.5

5150

10300

... More
Supply & stringing of AA"GNAT" conductor

0.23

2093

9100

... More
Supply & Erection of MS Distribution box along with MCCB 400 A, Bus bar made out of Aluminium strips 40 x 10 mm, kit kat fuses for 4 feeder arrangement

1

8795

8795

... More
Supply & Stringing of XLPE 1.1KV Armored single core unarmoured cable 300 mm²

48

12720

265

... More
Supply & stringing of XLPE 1.1KV 3 & 1/2 XLPE Armoured cable 120 mm²

36

6336

176

... More
Supply & Erection of Enamelled danger boards 11000 Volts ,250mm x 200mmm

2

114

57

... More
Supply & Erection of Aluminium crimping Lugs shall as amended upto date. Lugs shall be made of aluminium of grade suitable for aluminium cable fo sizes 300 Sq.mm.

8

808

101

... More
Supply & Erection of Aluminium crimping Lugs shall as amended upto date. Lugs shall be made of aluminium suitable for aluminium cable fo sizes 120 Sq.mm.

9

792

88

... More
Supply & Erection of Aluminium crimping Lugs . Lugs shall be made of aluminium of grade IE of suitable for aluminium cable fo sizes 95 Sq.mm.

3

195

65

... More
Supply & Erection of Aluminium crimping Lugs as amended upto date. Lugs shall be made of aluminium of grade IE of IS: 5082/1969 suitable for aluminium cable fo sizes50 Sq.mm.

55

2805

51

... More
Supply & Erection of DTC metering unit

1

1072

1072

... More
Cement concreting 1 : 2:4

2

11110

5555

... More
Removing of 9 Mts long RCC pole

1

2950

2950

... More
Removing of 11KV GOAB switch 200 A, 3 Pole DP AB Switch

1

1985

1985.5

... More
Removing of 11KV 200 A H.G Fuse unit

1

1684

1684

... More
Removing of 9kv, 5KA lightening Arrestor pole mounted.

3

261

87

... More
Removing of HDGI structural material

260

6110

23.5

... More
Removing of MS Distribution Box

1

4397

4397.5

... More
Removing of LT 4 pin cross arm of 75x40 channel with clamps & nut bolt for 9 mtr RCC pole

3

477

159

... More
Removing of LT 2-pin cross arm of 75x40 channel with clamps & nut bolts for 9 mtr RCC pole

2

289

144.5

... More
Removing of Shackle insulator with metal parts

15

1560

104

... More
Removing of AA ANT Conductor

0.3

1545

5150

... More
Removing of AA GNAT Conductor

0.15

682

4550

... More
Removing of XLPE 1.1KV 3 & 1/2 c cable 120 sq. mm²

10

880

88

... More
Removing of XLPE 1.1KV 3 & 1/2 c cable 95 sq. mm²

36

2682

74.5

... More
Removing of 100 KVA transformer

1

5508

5508.5



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.