Electricity Department Tender

View complete overview of Goa Electricity Department Tender

Electricity Department Tender

Works
Energy, Oil and Gas
Eprocure
Opening Date28 Dec 2024
Closing Date13 Jan 2025
Tender Amount₹ 9,02,44,240 
Notes
Download

Costs

  • EMD

    ₹ 18,04,885
  • Document Cost

    ₹ 1,500
  • Tender Fee

    ₹ 6,000

Summary

Work Of Conversion Of 11kv Bondla Feeder From Overhead To Underground Network From Primary Health Centre Usgao To Usgao Barazan Circle Under The Jurisdiction Of Section Office Usgaon, Sub Division-ii, Division-x, Ponda.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Sand for cushoning of HT underground cables. Single circuit cable sand required +Double circuit cable sand required

899.67

2170

1952292.58

... More
Supply of 11KV, 3 Core 300 sq.mm A2XFY Aluminium Armoured XLPE cable through conventional open trenching method in any type of soil including hard laterite and for HDD method

14800

2595

38406000

... More
Supply and erection of straight through joints for 300 sq.mm cable

56

29559

1655304

... More
Supply and laying of underground cable protective covers of size 480mm long 250mm width and 50 mm thick having strength of 30N/mm2

27751

135

3746385

... More
Warning Tape

11.6

15000

174000

... More
3Way RMU, 11 KV, 630 A, 21 KA 3 Sec, SF6 Outdoor RMU-2LBS + 1 CBExtensible/Non Extensible Two (2) Motor operated load break switches (LBSs) with manual orerated eathing switches in SF6 and one (1) vaccum circuit breaker with electrical closing and tripping along with disconnector and earthing switches SCADA compatible and base channel, battery charger along with batteries required for electrical operations of RMU is in the scope of the bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no 's per RMU current transformer and numerical relay with communication in all CB module . Suitable arrangement for mounting FRTU , modem or Ethernet switch /LIU along the battery, battery charger shall be provided in RMU. Auxillary PT as per specification shall be provided in RMU.

19

735000

13965000

... More
3 Way RMU, 11KV, 630A, 21KA 3sec, SF6 Outdoor RMU-3LBS a. Extensible/Non-Extensible Three(3) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operationsof RMU is in the scope of the bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no.s per RMU. Suitable arrangementn for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU. Auxillary PT as per specification shall be provided in RMU.

3

720000

2160000

... More
4 Way RMU, 11KV, 630A, 21KA 3sec, SF6 Outdoor RMU-4LBS a. Extensible/Non-Extensible Three(4) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operationsof RMU is in the scope of the bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no.s per RMU. Suitable arrangementn for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU. Auxillary PT as per specification shall be provided in RMU.

5

917000

4585000

... More
4 Way RMU, 11KV, 630A, 21KA 3sec, SF6 Outdoor RMU-3LBS+1CB a. Extensible/Non-Extensible Three(4) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operationsof RMU is in the scope of the bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no.s per RMU. Suitable arrangementn for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU. Auxillary PT as per specification shall be provided in RMU.

1

990000

990000

... More
11KV, 3 core, 95sq.mm, AL conductor, XLPE insulated, armoured cable (from the RMU to the transformer)

440

1240

545600

... More
11KV 3 phase indoor terminating kit to be used with cables - 300 sq.mm.

70

8840

618800

... More
11KV 3 phase outdoor terminating kit to be used with cables - 300 sq.mm.

2

11667

23334

... More
11KV 3 phase indoor terminating kit to be used with cables - 95sq.mm.

20

6731

134620

... More
11KV 3 phase outdoor terminating kit including sockets at 11KV end of DT to be used with cables as per -95sq.mm.

20

10152

203040

... More
Cable Route marker

256

528

135168

... More
Earthing complete with 40mm GI Pipe, 2.5mts long along with 20kgs each salt, charcoal complete.

56

2730

152880

... More
HDGI flat of size 25mm X 5mm for eathing.

448

116

51968

... More
Bricks required between double circuit (0.2*0.1*0.1)

20000

9

190000

... More
Cost of Erection

-

-

-

... More
Earthwork in excavation by mechanical means(hydraulic excavator)/manual means over areas(exceeding 30cm in depth, 1.5 m in width as well as 10sq.m on plan) including disposalof excavated earth lead upto 50M and lift upto 1.5 m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in. a. All kinds of soil

4032

468

1886976

... More
Earthwork in excavation by mechanical means(hydraulic excavator)/manual means over areas(exceeding 30cm in depth, 1.5 m in width as well as 10sq.m on plan) including disposalof excavated earth lead upto 50M and lift upto 1.5 m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in. b. All type of ordinary rock including all types of laterite rock, blasting prohibited.

1512

763

1153656

... More
RCC Hume pipe 250mm dia with required no. of collars, for road crossig

280

254

71120

... More
GI Pipe 100 mm, class B for nalla crossing and for cable rising on D.P of DTC

278

92

25576

... More
Supply and erection of straight through joints for 300 sq.mm cable

56

3713

207928

... More
Supply and laying of underground cable protective covers of size 480mm long 250mm width and 50 mm thick having strength of 30N/mm2

27751

60

1665060

... More
Refilling the pipeline /foundation trenches plinth sides, foundation etc. with available excavated eath in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead up to 50 M and all lifts and disposal of surplus earth aas dirrected by Engineer in charge.

4366

120

523920

... More
3Way RMU, 11 KV, 630 A, 21 KA 3 Sec, SF6 Outdoor RMU-2LBS + 1 CBExtensible/Non Extensible Two (2) Motor operated load break switches (LBSs) with manual orerated eathing switches in SF6 and one (1) vaccum circuit breaker with electrical closing and tripping along with disconnector and earthing switches SCADA compatible and base channel, battery charger along with batteries required for electrical operations of RMU is in the scope of the bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no 's per RMU current transformer and numerical relay with communication in all CB module . Suitable arrangement for mounting FRTU , modem or Ethernet switch /LIU along the battery, battery charger shall be provided in RMU. Auxillary PT as per specification shall be provided in RMU.

19

9720

184680

... More
3 Way RMU, 11KV, 630A, 21KA 3sec, SF6 Outdoor RMU-3LBS a. Extensible/Non-Extensible Three(3) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operationsof RMU is in the scope of the bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no.s per RMU. Suitable arrangementn for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU. Auxillary PT as per specification shall be provided in RMU.

3

9720

29160

... More
4 Way RMU, 11KV, 630A, 21KA 3sec, SF6 Outdoor RMU-4LBS a. Extensible/Non-Extensible Three(4) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operationsof RMU is in the scope of the bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no.s per RMU. Suitable arrangementn for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU. Auxillary PT as per specification shall be provided in RMU.

5

9720

48600

... More
4 Way RMU, 11KV, 630A, 21KA 3sec, SF6 Outdoor RMU-3LBS+1CB a. Extensible/Non-Extensible Three(4) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operationsof RMU is in the scope of the bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no.s per RMU. Suitable arrangementn for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU. Auxillary PT as per specification shall be provided in RMU.

1

9720

9720

... More
11KV, 3 core, 95sq.mm, AL conductor, XLPE insulated, armoured cable (from the RMU to the transformer)

440

199

87560

... More
11KV 3 phase indoor terminating kit to be used with cables - 300 sq.mm.

70

2548

178360

... More
11KV 3 phase outdoor terminating kit to be used with cables - 300 sq.mm.

2

2718

5436

... More
11KV 3 phase indoor terminating kit to be used with cables - 95sq.mm.

20

2538

50760

... More
11KV 3 phase outdoor terminating kit including sockets at 11KV end of DT to be used with cables as per -95sq.mm.

20

2648

52960

... More
Cable Route marker

256

256

65536

... More
Earthing complete with 40mm GI Pipe, 2.5mts long along with 20kgs each salt, charcoal complete.

56

2444

136864

... More
HDGI flat of size 25mm X 5mm for eathing.

448

48

21504

... More
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width .as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : a) All types of Ordinary rock including all types of laterite rock. blasting prohibited

145.88

639

93217.32

... More
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge.

8.12

245

1989.4

... More
Providing and laying in position cement concrete 1:3:6 (1 cement : 3 coarse sand:6 graded granitic or basaltic stone aggregate 20 m nominal size) excluding cost of centering, stuttering and finishing : a) All works upto plinth level

9.5

6325

60087.5

... More
Centering & shuttering including Strutting, Propping & removal of forms for : i. Foundations, Footings, Bases for columns

52.84

407

21505.88

... More
Centering & shuttering including Strutting, Propping & removal of forms for : ii. Vertical surfaces such as retaing walls, return walls, Partitions, walls (any thickness) including attached Pilasters, Buttresses, Plinth and string courses, Fillets and the like

217.8

479

104326.2

... More
Providing and laying in position (1:11/2:3) Reinforced cement conrete excluding the cost of centering, shuttering, finishing and reinfrocement (1 cement: 1½ coarse sand:3 graded stone agg 20mm nominal size) i. All works upto plinth level

8.1

7178

58141.8

... More
Providing and laying in position (1:11/2:3) Reinforced cement conrete excluding the cost of centering, shuttering, finishing and reinfrocement (1 cement: 1½ coarse sand:3 graded stone agg 20mm nominal size) ii. In walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and structs etc. upto floor five level

18.28

8034

146861.52

... More
Providing TMT steel reinforcement bars of (SAIL, TATA. VIZAG, JSW Steel Ltd.) ) (Confirming to IS 1786 of 1986) for RCC work (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in all the floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member.

2110.4

105

221592

... More
Laterite Masonary Works Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches aand other foundations complete, for a. Single circuit 11KV cable trench (0.2X0.7X1)i.e 0.14per RM

1344

2211

2971584

... More
Laterite Masonary Works Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches aand other foundations complete, for b. Double circuit 11KV cable trench (0.2X0.9X1)i.e 0.18per RM

360

2211

795960

... More
Laying of HT UG cables by trenchless technology by adopting horizontal boring . The work includes preparation of site, Boring as well as drawing of cable in Hard Laterite soil with minimum 8" bore size with HDPE pipe.

1200

3600

4320000

... More
Laying of 11KV, 3 Core 300 sq.mm A2XFY Aluminium Armoured XLPE cable through conventional open trenching method in any type of soil including hard laterite.

13600

342

4651200

... More
Removal of 11.0 mtrs long R.C.C. Pole

10

4900

49000

... More
Removal of 9.0 mtrs long RCC Pole

15

2950

44250

... More
Removal of M.S. Rail Pole90 lb/yd 13 mtr

5

11377

56887.5

... More
Removal of 11 KV HDG 'V' shape X-arm

20

169

3380

... More
Removal of Guard X-arm

2

273

546

... More
Removal of HDGI Cut point channel

5

246

1230

... More
Removal of Top insulator fitting LT/11KV

30

114

3420

... More
Removal of HDGI X-arm clamps of RCC pole 11.0mtrs Long LA/SA

10

32

325

... More
Removal of HDGI X-arm clamps of RCC pole 9.0mtrs Long LA/SA

15

22

337.5

... More
Removal of HDGI X-arm clamps of Rail pole 90 lb/yd

5

34

172.5

... More
Removal of 11KV disk insulator 45KN with Metal parts

30

166

4980

... More
Removal of 11KV pin insulator with Gi pins

60

76

4560

... More
Removal of ACSR "Weasel" Conductor

15

5500

82500



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.