Supply Of Laboratory Equipment For The Project, Project 2: Establishment Of Pharmaceutical Sciences Services For Clinical Research , Laboratory Supplies And Equipment ,university Of The Philippines - Manila
Description
Description Supply Of Laboratory Equipment For The Project, Project 2: Establishment Of Pharmaceutical Sciences Services For Clinical Research Disintegration Test System General Specifications: Instrument Dimensions: Width: 35 - 45 Cm; Depth: 45 - 55 Cm; Height: 40 - 50 Cm Net Weight: Maximum Of 18 Kg ● Number Of Testing Stations: 3 Baskets ● Stroke Height: 50 - 60 Mm ● Stroke Frequency: 30 Strokes Per Minute ● Strokes Accuracy: ±1 Strokes ● Temperature Range: Adjustable From 25.0 To 45.0 °c ● Temperature Accuracy: ± 0.3 °c ● With Safety Systems Pressure Switch ● With Thermal Switch And Thermal Fuse ● Testing Time Range: 00:00:01 To 99:59:59 (hh:mm:ss) ● Stores At Least 250 Test Descriptions (methods) And 30 Users ● Complies To United States Pharmacopeia <701/2040> ● Determine Disintegration Time Of Tablets, Capsules And Other Dosage Forms ● Result Report Includes Disintegration Time, Actual Temperature And Number Of Persisting Samples After Tested, And Evaluation Of The Test Result ● Password Protected Access Through User Management System ● Export Test Reports As Text Files ● Self-sealing Quick Connect Water Bath Connectors ● User Management System ● Method Management System ● Integrated Calibration Programs ● Graphical Lcd Screen Showing Actual And Target Settings ● Data Entry Keypad With Function Keys And Click Wheel ● Programmable Qualification Interval Timer Reminds The User To Perform Instrument Calibration ● Dedicated Calibration Programs And Reports ● Instrument Housing Polished Stainless-steel Housing With Plastic Frame ● Power 220 Volt, 50/60 Hz Inclusions: ❖ One “a”-type Disintegration Basket For Each Testing Station ❖ One Set Of Six Glass Tubes For Each Disintegration Basket ❖ One Set Of Six Disintegration Disks For Each Disintegration Basket ❖ One Flat Bottom Disintegration Vessel For Each Testing Station ❖ One Temperature Probe ❖ One Bottle Of Water Preservative ❖ Comprehensive Documentation Included (pdf & Hardcopies): - User Manual - Dq/qc Instrument Compliance Test Certificate - Iq Documentation - Oq Documentation - Instrument Logbook Terms And Conditions: 1. Delivery And Installation Of Equipment Should Be Done Upon The Completion Of The Renovation Of Compounding & Product Development Facility At The College Of Pharmacy. 2. With Installation And Calibration Free Of Charge 3. With Iq/oq/pq Documentation Pack And Qualification Tools 4. All Parts Of The Equipment And Its Accessories Must Be Identified By Part Number Or Accessory Number 5. Installation And Calibration Of The Equipment And Initial Operation By Service Engineer 6. Qualified Service Engineers Must Perform Installation Qualification (iq) And Operational Qualification (oq) With Documentation And Report 7. Operations And Service Manual Must Be Provided 8. Local Training Of At Least 2 End-user (personnel) To Operate, Troubleshoot And Maintain Equipment 9. Warranty, Parts, And Preventive Maintenance For Two (2) Years Or More 10. Provision Of Free Accessories/consumables, If Applicable 11. Certification/guarantee On Availability Of Parts, Accessories, Supplies For The Next 10 Years Or More 12. Warranty Period Shall Commence From The Date Of Acceptance By The End-user After Installation, Testing And Commissioning 13. Bi-annual Preventive Maintenance From The Distributor's Qualified Technician During The Warranty Period 14. Availability Of Trained Service Engineers With Guaranteed Uptime Within 48 Hours For Troubleshooting And Repair Of Unit Even After The Warranty Period. Friabilator General Specifications Instrument Dimensions: Width: 45 - 55 Cm; Depth: 35 - 45 Cm; Height: 40 - 50 Cm Net Weight: Maximum Of 20-kg ● Number Of Test Drums: 2 (1 Right Side And 1 Left Side) ● Drum Rotation Speed Range: 15 – 100 Rpm ● Speed Accuracy: ±1 Rpm ● Number Of Rotations: Adjustable From 2 To 9999 (switchable To Time Mode) ● Testing Time: Adjustable From 2 To 9999 Seconds (switchable To Rotations Mode) ● Method Management: Approximately Up To 256 Test Descriptions (methods) ● User Management: Approximately Up To 32 Users With Selectable User Right Levels ● Graphical Lcd Screen Showing Actual And Target Settings ● Instrument Housing Polished Stainless-steel Housing With Plastic Frame ● Keypad With Function Keys And Click Wheel ● Detailed Result Report Including Weight Loss Calculation And Evaluation Of The Results ● Determine Friability Of Uncoated Tablets ● Programmable For Number Of Drum Revolutions Or Rotating Time ● Fully Complies With United States Pharmacopeia <1216> ● User And Method Management System ● Drum Is Easy To Open For Loading And Cleaning, Alternatively Use Discharge Opening For Loading ● Automated Sample Discharge At The End Of A Test Run ● Dual Operation Mode: Number Of Revolutions Or Rotation Time ● Variable Drum Rotation Speed Or Locked Speed Mode ● Determine The Sample Weight By Balance To Automatically Calculate Weight Loss ● Programmable Qualification Interval Timer Reminds The User To Perform Instrument Calibration ● Dedicated Calibration Programs And Reports ● Export Test Reports As Text Files ● Power 230 Volt, 50/60 Hz Inclusions: ❖ Integrated Protocol Printer ❖ Two Friability Drums Made From Plexiglas In Compliance With The Us Pharmacopeia ❖ Comprehensive Documentation Included (pdf And Hardcopies): - User Manual - Dq/qc Instrument Compliance Test Certificate - Iq Documentation - Oq Documentation - Instrument Logbook Terms And Conditions: 1. Delivery And Installation Of Equipment Should Be Done Upon The Completion Of The Renovation Of Compounding & Product Development Facility At The College Of Pharmacy. 2. With Installation And Calibration Free Of Charge 3. With Iq/oq/pq Documentation Pack And Qualification Tools 4. All Parts Of The Equipment And Its Accessories Must Be Identified By Part Number Or Accessory Number 5. Installation And Calibration Of The Equipment And Initial Operation By Service Engineer 6. Qualified Service Engineers Must Perform Installation Qualification (iq) And Operational Qualification (oq) With Documentation And Report 7. Operations And Service Manual Must Be Provided 8. Local Training Of At Least 2 End-user (personnel) To Operate, Troubleshoot And Maintain Equipment 9. Warranty, Parts, And Preventive Maintenance For Two (2) Years Or More 10. Provision Of Free Accessories/consumables, If Applicable 11. Certification/guarantee On Availability Of Parts, Accessories, Supplies For The Next 10 Years Or More 12. Warranty Period Shall Commence From The Date Of Acceptance By The End-user After Installation, Testing And Commissioning 13. Bi-annual Preventive Maintenance From The Distributor's Qualified Technician During The Warranty Period 14. Availability Of Trained Service Engineers With Guaranteed Uptime Within 48 Hours For Troubleshooting And Repair Of Unit Even After The Warranty Period. Reference Standard Temperature & Humidity Controlled Chamber General Specifications Tailor-made For Stability Studies According To International Council For Harmonization Instrument Dimensions: Width: 815 - 825 Mm; Height: 1715 - 1725 Mm; Depth: 650 - 660 Mm (width X Height X Depth) (d Around +50-mm Door Handle & Around +110-mm Peltier Element) Volume: Maximum Of 400 L ● Fully Insulated Stainless Steel Door With 2-point Locking (compression Door Lock); Inner Glass Door ● Internals: 2 Stainless Steel Grid(s), Electropolished ● Max Number Of Internals: 14 ● Max Loading Of Chamber: 200-kg ● Max Loading Per Internal: 14-kg ● Installation: On Lockable Castors ● Housing: Rear Zinc-plated Steel ● Voltage Electrical Load: 230 V, 50/60 Hz, 700 W ● With Uninterruptible Power Supply Temperature Setting Temperature Range: Without Light, With Humidity: +5 To +70 °c With Light, With Humidity: +5 To +70 °c With Light, Without Humidity: 0 To +70 °c Without Light, Without Humidity: 0 To +70 °c Working Temperature Range: With Light, Without Or With Humidity: 15 To +40 °c Without Light, With Humidity: +5 (at Least 20 Below Ambient Temperature) To +70 °c Without Light, Without Humidity: 0 (at Least 20 Below Ambient Temperature) To +70 °c Humidity Setting Range Humidity: 10 - 90 % Rh Humidity: Humidity Supply With Distilled Water From External Tank By Self-priming Pump Humidification: Humidification By Hot Steam Generator Dehumidification: Dehumidification By Cold Trap Using The Peltier Technology Setting Accuracy Humidity: Around 0.5% Rh Settling Accuracy Temperature: Around 0.1 °c Inclusions: Control Technology ❖ Adaptive Multifunctional Digital Pid-microprocessor Controller With 2 High-definition Tft-colour Displays. ❖ Timer: Digital Backwards Counter With Target Time Setting, Adjustable From 1 Minute To 99 Days ❖ Function Heatbalance: Adapting The Distribution Of The Heating Performance Of The Upper And Lower Heating Circuit From -50 % To +50 % ❖ Calibration: Three Freely Selectable Values Each, Temperature And Humidity Communication ❖ Documentation: Program Stored In Case Of Power Failure Safety ❖ Temperature Control: Over- And Under Temperature Monitor Tww, Protection Class 3.3 Or Adjustable Temperature Limiter Twb, Protection Class 2, Selectable On Display ❖ Autosafety: Additionally Integrated Over- And Under Temperature Protection “asf”, Automatically Following The Setpoint Value At A Preset Tolerance Range, Alarm In Case Of Over- Or Under Temperature, Heating Function Is Switched Off In Case Of Overtemperature, Cooling Function In Case Of Under Temperature ❖ Autodiagnostic System: Integral Fault Diagnostics For Temperature And Humidity Control Heating Concept ❖ Peltier: Energy-saving Peltier Heating-/cooling System Integrated In The Rear (heat Pump Principle) ❖ Standard Accessories: Water Tank Including Connection Hose (110-750: 2.5 Liter, 1060-2200: 10 Liter) ❖ Works Calibration Certificate: Standard Values +10 °c And +37 °c, 60 % Rh At +30 °c Comprehensive Documentation Included (pdf And Hardcopies): - User Manual - Dq/qc Instrument Compliance Test Certificate - Iq Documentation - Oq Documentation - Instrument Logbook Terms And Conditions: 1. Delivery And Installation Of Equipment Should Be Done Upon The Completion Of The Renovation Of Compounding & Product Development Facility At The College Of Pharmacy. 2. With Installation And Calibration Free Of Charge 3. With Iq/oq/pq Documentation Pack And Qualification Tools 4. All Parts Of The Equipment And Its Accessories Must Be Identified By Part Number Or Accessory Number 5. Installation And Calibration Of The Equipment And Initial Operation By Service Engineer 6. Qualified Service Engineers Must Perform Installation Qualification (iq) And Operational Qualification (oq) With Documentation And Report 7. Operations And Service Manual Must Be Provided 8. Local Training Of At Least 2 End-user (personnel) To Operate, Troubleshoot And Maintain Equipment 9. Warranty, Parts, And Preventive Maintenance For Two (2) Years Or More 10. Provision Of Free Accessories/consumables, If Applicable 11. Certification/guarantee On Availability Of Parts, Accessories, Supplies For The Next 10 Years Or More 12. Warranty Period Shall Commence From The Date Of Acceptance By The End-user After Installation, Testing And Commissioning 13. Bi-annual Preventive Maintenance From The Distributor's Qualified Technician During The Warranty Period 14. Availability Of Trained Service Engineers With Guaranteed Uptime Within 48 Hours For Troubleshooting And Repair Of Unit Even After The Warranty Period. Sieve Shaker Instrument Dimension: Width: 375 - 385 Mm; Depth: 375 - 385 Mm; Height: 1135 - 1145 Mm Net Weight: Maximum Weight Of 30 Kg General Specifications ● Variable-speed, Digital, Sieve Shaker, Variable-speed Option, Easy-to-use Digital Interface With An Accuracy Of 0.5% ● Can Be Used With 3", 5" And 8" Sieves ● Can Handle Up To Ten 8" Sieves, Twelve 5" Sieves, Sixteen 3" Full-height Sieves Or Eighteen Half-height 8" Sieves ● Provides A Wide Range Of Setting Inclusions: ❖ Analytical Sieves: 1. 8" Dia., No. 4 (4.75mm) Stainless Frame Stainless Mesh, 2" (50mm) Full Height Frame Standard Sieve 2. 8" Dia., No. 10 (2.00mm) Stainless Frame Stainless Mesh, 2" (50mm) Full Height Frame Standard Sieve 3. 8" Dia., No. 20 (850μm) Stainless Frame Stainless Mesh, 2" (50mm) Full Height Frame Standard Sieve 4. 8" Dia., No. 30 (600μm) Stainless Frame Stainless Mesh, 2" (50mm) Full Height Frame Standard Sieve 5. 8" Dia., No. 40 (425μm) Stainless Frame Stainless Mesh, 2" (50mm) Full Height Frame Standard Sieve 6. 8" Dia., No. 50 (300μm) Stainless Frame Stainless Mesh, 2" (50mm) Full Height Frame Standard Sieve 7. 8" Dia., No. 60 (250μm) Stainless Frame Stainless Mesh, 2" (50mm) Full Height Frame Standard Sieve 8. 8" Dia., No. 70 (212μm) Stainless Frame Stainless Mesh, 2" (50mm) Full Height Frame Standard Sieve 9. 8" Dia., No. 80 (180μm) Stainless Frame Stainless Mesh, 2" (50mm) Full Height Frame Standard Sieve 10. 8" Dia., No. 100 (150μm) Stainless Frame Stainless Mesh, 2" (50mm) Full Height Frame Standard Sieve ❖ Comprehensive Documentation Included (pdf And Hardcopies): - User Manual - Dq/qc Instrument Compliance Test Certificate - Iq Documentation - Oq Documentation - Instrument Logbook Terms And Conditions: 1. Delivery And Installation Of Equipment Should Be Done Upon The Completion Of The Renovation Of Compounding & Product Development Facility At The College Of Pharmacy. 2. With Installation And Calibration Free Of Charge 3. With Iq/oq/pq Documentation Pack And Qualification Tools 4. All Parts Of The Equipment And Its Accessories Must Be Identified By Part Number Or Accessory Number 5. Installation And Calibration Of The Equipment And Initial Operation By Service Engineer 6. Qualified Service Engineers Must Perform Installation Qualification (iq) And Operational Qualification (oq) With Documentation And Report 7. Operations And Service Manual Must Be Provided 8. Local Training Of At Least 2 End-user (personnel) To Operate, Troubleshoot And Maintain Equipment 9. Warranty, Parts, And Preventive Maintenance For Two (2) Years Or More 10. Provision Of Free Accessories/consumables, If Applicable 11. Certification/guarantee On Availability Of Parts, Accessories, Supplies For The Next 10 Years Or More 12. Warranty Period Shall Commence From The Date Of Acceptance By The End-user After Installation, Testing And Commissioning 13. Bi-annual Preventive Maintenance From The Distributor's Qualified Technician During The Warranty Period 14. Availability Of Trained Service Engineers With Guaranteed Uptime Within 48 Hours For Troubleshooting And Repair Of Unit Even After The Warranty Period. Sonicator/ultrasonic Bath (5.7l Capacity) General Specifications Tank Size: Width: 285 - 295 Mm; Depth: 145 - 155 Mm; Height: 145 - 155 Mm Overall Size: Width: Width: 385 - 399 Mm; Depth: 305 - 320 Mm; Height: 325 - 340 Mm Maximum Weight: 6.0 Kg Tank Capacity: Exactly 5.7-l ● 40 Khz Rugged Industrial Transducers, Sweep Frequency ● With Heater (with Option For °c Or °f Temperature) ● Auto Ultrasonics Activation ● Front Panel Auto Temp Calibration ● Plastic Body & Chemical-resistant ● With Drain Functions: ● Dual Power ● Power Tracking ● Sleep Mode ● Degas Wave Modulation ● High-temp Alarm Inclusions: ❖ Comprehensive Documentation Included (pdf And Hardcopies): - User Manual - Dq/qc Instrument Compliance Test Certificate - Iq Documentation - Oq Documentation - Instrument Logbook Terms And Conditions: 1. Delivery And Installation Of Equipment Should Be Done Upon The Completion Of The Renovation Of Compounding & Product Development Facility At The College Of Pharmacy. 2. With Installation And Calibration Free Of Charge 3. With Iq/oq/pq Documentation Pack And Qualification Tools 4. All Parts Of The Equipment And Its Accessories Must Be Identified By Part Number Or Accessory Number 5. Installation And Calibration Of The Equipment And Initial Operation By Service Engineer 6. Qualified Service Engineers Must Perform Installation Qualification (iq) And Operational Qualification (oq) With Documentation And Report 7. Operations And Service Manual Must Be Provided 8. Local Training Of At Least 2 End-user (personnel) To Operate, Troubleshoot And Maintain Equipment 9. Warranty, Parts, And Preventive Maintenance For Two (2) Years Or More 10. Provision Of Free Accessories/consumables, If Applicable 11. Certification/guarantee On Availability Of Parts, Accessories, Supplies For The Next 10 Years Or More 12. Warranty Period Shall Commence From The Date Of Acceptance By The End-user After Installation, Testing And Commissioning 13. Bi-annual Preventive Maintenance From The Distributor's Qualified Technician During The Warranty Period 14. Availability Of Trained Service Engineers With Guaranteed Uptime Within 48 Hours For Troubleshooting And Repair Of Unit Even After The Warranty Period Stereomicroscope General Specifications Instrument Dimensions: Width: 15 - 25 Cm; Depth: 20 - 30 Cm; Height: 30 - 50 Cm Microscope: ● Zoom Ratio: Around 6.0:1.0 ● Zoom Magnification: Around 0.65x To 4.5x ● Optical Components: Lead Free ● With Transmitted And Reflected Led Illumination ● With 5 Magnification Click / Zoom Stops: 0.67x, 1x, 2x, 3x, 4.5x ● Inocular Port With C-mount (built-in) ● Eyepiece 10x With Esd Capability Camera: ● At Least 6.4-megapixel Color Camera ● Imaging Sensor ● Sensor Type: Around 1/1.8-inch Color Cmos ● Shutter Type: Rolling Shutter ● Pixel Size: Around 2.4 Μm × 2.4 Μm ● Resolution: Around 3088 × 2076 (full Resolution) ● Measuring Function: Measurement Function Count, Distance Between 2 Points, Polyline, 3-point Circle, Rectangle, 3-point Angle, 4-point Angle, Perpendicular, Area And Perimeter Of Polygon, Distance Between 2 Centers, Ruler ● 60 Fps At Full Hd ● Compatible To 4k Display Inclusions: ❖ Pc System Processor: Intel Core I7 Memory: 8gb 2400 Ddr4 Hard Drive: 512 Gb Ssd Operating System: Windows 10 Mouse & Keyboard Monitor Microsoft Office ❖ Uninterruptible Power Supply (ups) ❖ Comprehensive Documentation Included (pdf And Hardcopies): - User Manual - Dq/qc Instrument Compliance Test Certificate - Iq Documentation - Oq Documentation - Instrument Logbook Terms And Conditions: 1. Delivery And Installation Of Equipment Should Be Done Upon The Completion Of The Renovation Of Compounding & Product Development Facility At The College Of Pharmacy. 2. With Installation And Calibration Free Of Charge 3. With Iq/oq/pq Documentation Pack And Qualification Tools 4. All Parts Of The Equipment And Its Accessories Must Be Identified By Part Number Or Accessory Number 5. Installation And Calibration Of The Equipment And Initial Operation By Service Engineer 6. Qualified Service Engineers Must Perform Installation Qualification (iq) And Operational Qualification (oq) With Documentation And Report 7. Operations And Service Manual Must Be Provided 8. Local Training Of At Least 2 End-user (personnel) To Operate, Troubleshoot And Maintain Equipment 9. Warranty, Parts, And Preventive Maintenance For Two (2) Years Or More 10. Provision Of Free Accessories/consumables, If Applicable 11. Certification/guarantee On Availability Of Parts, Accessories, Supplies For The Next 10 Years Or More 12. Warranty Period Shall Commence From The Date Of Acceptance By The End-user After Installation, Testing And Commissioning 13. Bi-annual Preventive Maintenance From The Distributor's Qualified Technician During The Warranty Period 14. Availability Of Trained Service Engineers With Guaranteed Uptime Within 48 Hours For Troubleshooting And Repair Of Unit Even After The Warranty Period. Tablet Thickness And Hardness Tester General Specifications: Instrument Dimensions: Length: 255 - 265 Mm; Width: 495 - 505 Mm; Height: 255 - 265 Mm Packaging Dimensions: Length: 305 - 315 Mm; Width: 655 - 665 Mm; Height: 415 - 425 Mm Net Weight: Maximum Of 10.0 Kg Gross Weight: Maximum Weight Of 13.0 Kg ● Hardness Accuracy Better Than ±1 N ● Hardness Resolution: 0.1 N ● Thickness Testing Range: 2.00 – 45.00 Mm ● Thickness Accuracy Better Than ±0.02 Mm ● Width Testing Range: 2.00 – 45.00 Mm ● Width Accuracy Better Than ±0.02 Mm ● Diameter Testing Range: 2.00 – 45.00 Mm ● Diameter Accuracy Better Than ±0.02 Mm ● Thickness, Width & Diameter Resolution: 0.01 Mm ● Measuring Units Thickness, Width And Diameter Selectable Between Millimeter And Inches ● Hardness Selectable Between Newton, Kilopond And Strong Cobb ● Force Mode Selectable: Linear Force Increase Or Linear Speed Increase ● Deactivate Any Measurement Not Required For A Particular Test ● Instrument Housing Stainless Steel (304) ● Power 230 Volt Ac, 50/60 Hz ● Current Consumption 0.15 A At 230 V; 35 W Main Fuse 2 X T1.0 A ● Installation Requirements: Ambient Temperature 15-35 °c ● Relative Humidity: 15-80 % Rh ● Desk With At Least 50 Kg Working Load ● Fully Us Pharmacopeia <1217> Compliant ● Measure Hardness, Diameter (or Length), Width And Thickness Of Tablets ● Dual Force Mode Instrument With Linear Speed Increase And Linear Force Increase Modes ● Multiple Point Validation Procedure Built-in ● Programmable Print-out Of Force Increase Curve ● Set To Test Tension Strength Of Oblongs And Caplets Available ● Select Either Linear Force Or Linear Speed Increase (dual Mode Selection) ● Stepless Adjustment Of The Force Or Speed Increasing Rate ● Entry Of Time And Date Password Protected ● Enter A 12-digit Batch Number ● Automatic Restart Facility To Speed Up The Testing Sequence Inclusions: ❖ Documentation Of All Results Using A Separate Pcl Or Dot-matrix Printer ❖ Validation And Calibration Program For The Measurement Station ❖ Dual Point Adjustment Of The Load Cell For The Hardness Test Station ❖ Multiple Point Validation (calibration) Up To 30 Or 50 Kg ❖ Programmable Print-out Of Force Increase Curve ❖ Data Transfer Via Rs-232 Interface With Usb Port ❖ Test Program For Soft Gelatin Capsule Testing By Setting Up A Testing Distance ❖ With Password Feature And Width Measurement ❖ Standard Jaw Set To Allow Hardness Test Of All Size And Shape Samples ❖ Broken Sample Collector ❖ Comprehensive Documentation Folder Including (pdf And Hardcopies): ○ User Manual ○ Qc/dq Testing Certificate ○ Iq Documentation ○ Oq Documentation ○ Conformity Declaration ○ Instrument Logbook Terms And Conditions: 1. Delivery And Installation Of Equipment Should Be Done Upon The Completion Of The Renovation Of Compounding & Product Development Facility At The College Of Pharmacy. 2. With Installation And Calibration Free Of Charge 3. With Iq/oq/pq Documentation Pack And Qualification Tools 4. All Parts Of The Equipment And Its Accessories Must Be Identified By Part Number Or Accessory Number 5. Installation And Calibration Of The Equipment And Initial Operation By Service Engineer 6. Qualified Service Engineers Must Perform Installation Qualification (iq) And Operational Qualification (oq) With Documentation And Report 7. Operations And Service Manual Must Be Provided 8. Local Training Of At Least 2 End-user (personnel) To Operate, Troubleshoot And Maintain Equipment 9. Warranty, Parts, And Preventive Maintenance For Two (2) Years Or More 10. Provision Of Free Accessories/consumables, If Applicable 11. Certification/guarantee On Availability Of Parts, Accessories, Supplies For The Next 10 Years Or More 12. Warranty Period Shall Commence From The Date Of Acceptance By The End-user After Installation, Testing And Commissioning 13. Bi-annual Preventive Maintenance From The Distributor's Qualified Technician During The Warranty Period 14. Availability Of Trained Service Engineers With Guaranteed Uptime Within 48 Hours For Troubleshooting And Repair Of Unit Even After The Warranty Period Tap Density Analyzer General Specifications Instrument Dimension: Width: 255 - 265 Mm; Depth: 335 - 345 Mm; Height: 555 - 565 Mm ● Test Station Capacity: 2 Cylinders ● Tapped Density Tester – Method 2, 250 Ml Cylinders ● Platform For Use With 100 Ml Cylinder ● Us Pharmacopeia Test Methods Supported ● Status Of ‘actual’ V ‘set’ Test Parameters Clearly Displayed Throughout Testing ● Resistive Touchscreen Interface Can Be Operated With Gloves On ● Calculation Of: Bulk Density Tapped Density Hausner Ratio Compressibility Index Inclusions: ❖ 100 Ml And 250 Ml Measuring Cylinder ❖ Comprehensive Documentation Folder Including (pdf And Hardcopies): ○ User Manual ○ Qc/dq Testing Certificate ○ Iq Documentation ○ Oq Documentation ○ Conformity Declaration ○ Instrument Logbook Terms And Conditions: 1. Delivery And Installation Of Equipment Should Be Done Upon The Completion Of The Renovation Of Compounding & Product Development Facility At The College Of Pharmacy. 2. With Installation And Calibration Free Of Charge 3. With Iq/oq/pq Documentation Pack And Qualification Tools 4. All Parts Of The Equipment And Its Accessories Must Be Identified By Part Number Or Accessory Number 5. Installation And Calibration Of The Equipment And Initial Operation By Service Engineer 6. Qualified Service Engineers Must Perform Installation Qualification (iq) And Operational Qualification (oq) With Documentation And Report 7. Operations And Service Manual Must Be Provided 8. Local Training Of At Least 2 End-user (personnel) To Operate, Troubleshoot And Maintain Equipment 9. Warranty, Parts, And Preventive Maintenance For Two (2) Years Or More 10. Provision Of Free Accessories/consumables, If Applicable 11. Certification/guarantee On Availability Of Parts, Accessories, Supplies For The Next 10 Years Or More 12. Warranty Period Shall Commence From The Date Of Acceptance By The End-user After Installation, Testing And Commissioning 13. Bi-annual Preventive Maintenance From The Distributor's Qualified Technician During The Warranty Period 14. Availability Of Trained Service Engineers With Guaranteed Uptime Within 48 Hours For Troubleshooting And Repair Of Unit Even After The Warranty Period Viscometer General Specifications Instrument Dimension: Width: 255 - 265 Mm; Depth: 335 - 345 Mm; Height: 555 - 565 Mm Programming: ● Stand-alone And With Software With Lifetime Updates Touch Screen Display With The Following: ● Enhanced Controls ● Real-time Graphing ● Supports Multiple Languages Displayed Info Or Parameters: ● Viscosity (cp Or Mpa•s) ● Temperature (°c Or °f) ● Shear Rate/stress ● % Torque ● Speed/spindle ● Step Program Status ● Math Model Features: ● Accuracy: ±1.0% Of Fsr ● Displayed With Test Data ● Repeatability: ±0.2% ● Interface: Usb Pc Interface Provides Optional Computer Control And Automatic Data Collection Capability ● Standard Spindles: Rv 2-7 Spindles ● Viscosity Range: Around 100 - 40m Mpa.s ● Spring Torque: Around 0.7100 Mnm ● Accuracy (fsr): ±1.0% ● Speed Range: Around 0.01-250rpm ● Gel-timer Functionality ● Temperature Sensing Range: Around -100˚c To 300˚c ● Temperature Accuracy: ±1˚c | -100˚c To +149˚c ±2˚c | +150˚c To +300˚c ● Data Storage: 150 Mb With Date And Time Stamp File ● Input Voltage: 90 - 260 Vac ● Input Frequency: 50/60hz Inclusions: ❖ Viscosity Wizard: Built-in Math Models For Data Analysis In Stand-alone Mode. ❖ Built-in Options: ● Math Modeling ● Temperature Control ● Yield Tests ● Programmable Qc Limits, ● Alarms, End Conditions ● Gel Timer Functionality ❖ 50/50 Premix Ethylene Glycol Solution, 1 Gallon ❖ Refrigerated Bath/ Mx Controller 230v ❖ Insulated Tubing ❖ Small Sample Adapter With Rtd And Cable ❖ Digital Leveling ❖ Start-up Wizard ❖ Magnetic Coupling Attachment ❖ Barcode Scanner ❖ Ups Good For 600w ❖ Pc System Processor: Intel Core I5 Memory: 8gb 2400 Ddr4 Hard Drive: 512 Gb Ssd Operating System: Windows 10 Mouse & Keyboard Monitor ❖ Comprehensive Documentation Folder Including (pdf And Hardcopies): ○ User Manual ○ Qc/dq Testing Certificate ○ Iq Documentation ○ Oq Documentation ○ Conformity Declaration ○ Instrument Logbook Terms And Conditions: 1. Delivery And Installation Of Equipment Should Be Done Upon The Completion Of The Renovation Of Compounding & Product Development Facility At The College Of Pharmacy. 2. With Installation And Calibration Free Of Charge 3. With Iq/oq/pq Documentation Pack And Qualification Tools 4. All Parts Of The Equipment And Its Accessories Must Be Identified By Part Number Or Accessory Number 5. Installation And Calibration Of The Equipment And Initial Operation By Service Engineer 6. Qualified Service Engineers Must Perform Installation Qualification (iq) And Operational Qualification (oq) With Documentation And Report 7. Operations And Service Manual Must Be Provided 8. Local Training Of At Least 2 End-user (personnel) To Operate, Troubleshoot And Maintain Equipment 9. Warranty, Parts, And Preventive Maintenance For Two (2) Years Or More 10. Provision Of Free Accessories/consumables, If Applicable 11. Certification/guarantee On Availability Of Parts, Accessories, Supplies For The Next 10 Years Or More 12. Warranty Period Shall Commence From The Date Of Acceptance By The End-user After Installation, Testing And Commissioning 13. Bi-annual Preventive Maintenance From The Distributor's Qualified Technician During The Warranty Period Availability Of Trained Service Engineers With Guaranteed Uptime Within 48 Hours For Troubleshooting And Repair Of Unit Even After The Warranty Period
Contact
Tender Id
17214fe7-5c1e-3440-a509-8f680d1a60b6Tender No
11093773Tender Authority
University Of The Philippines ViewPurchaser Address
-Website
https://www.up.edu.ph/