University Of The Philippines Tender
University Of The Philippines Tender
Costs
Summary
Supply Of Various Laboratory Equipment For The Project Entitled, Project 2 Establishment Of Pharmaceutical Sciences Services For Clinical Research (107-198) , Laboratory Supplies And Equipment ,university Of The Philippines - Manila
Description
Description (2) Chemical Storage Cabinet General Specifications: - Internal Volume: 400 To 450 L - Dimensions Interior (w X D X H): 20-22 X 17-19 X 66-68 Inches - Dimensions Exterior (w X D X H): 24-26 X 20-22 X 73-75 Inches - Can Put 3 To 6 Shelves Inside - Can Put 4 To 7 Trays Inside - Maximum Load Per Shelf Is 50 Kg Or More - Made With Corrosion-resistant Interior Material - Compatible With Extraction Module As A Filter Inclusions: - At Least 3 Shelves - 4 Corrosion-resistant Pp Trays - 1 Extraction Module Terms And Conditions: 1. Supplier Shall Indicate Brand, Model, And Country Of Origin. 2. The Supplier Will Provide A Notarized Certificate Indicating That The Product Is Brand New, Not Reconditioned/refurbished Including Parts And Accessories. 3. Comes With Free Delivery To The Institute Of Pharmaceutical Sciences, National Institutes Of Health, Up Manila, And Setup, Which Should Be Done Within 90-120 Days Upon Acceptance Of Notice To Proceed. Note That Acknowledgment By The Supplier Through Email Constitutes The Date Of Acceptance. 4. The Supplier Will Witness And Help Unpack The Equipment To Ensure That All Items Are Inside And In Good Condition. 5. Free Relocation And Re-setup Of Equipment If Requested By The End-user Within The University Of The Philippines Manila Area Within The Warranty Period With Subsequent Installation Qualification And Operational Qualification With Documentation And Report. 6. Qualified Service Engineer/s Must Perform Operational Qualification With Documentation And Report. 7. The Equipment Must Be Delivered And Ready To Use. Cables, Connectors, Adapters, And Accessories Even Not Specified But Are Essential For The Unit To Function Must Be Provided Free By The Winning Bidder. 8. Certification From The Manufacturer/local Distributor That In The Event Of A Change Of Local Distributor, Preventive Maintenance, Warranty, And Services Agreed Here Upon Will Be Honored By The Principal Manufacturer. 9. Certification Or Guarantee Letter From The Manufacturer/local Distributor To Ensure The Availability Of Parts, Supplies, And Accessories Will Not Be Discontinued For The Next 10 Years. 10. Undertaking To Provide Product Orientation And Operations Training For End-users And Troubleshooting Training For Research Staff Within Seven Days After Completion Of Installation. 11. Provide Free Preventive Maintenance And Calibration From The Distributor’s Qualified Engineer During The Warranty Period. 12. At Least A 1-year Warranty On Parts And Services. The Warranty Period Shall Commence From The Date Of Acceptance By The End-user, Testing, And Commissioning. 13. The Bidder Must Submit Certification That They Have The Capability For Corrective And Preventive Maintenance Of The Unit. 14. Availability Of Trained Service Engineers With Guaranteed Uptime Within 48 Hrs For Troubleshooting And Repair Of Unit Even After The Warranty Period. 15. Provide Operator’s And Service Manual (in English) Upon Delivery. 16. Price Should Be Inclusive Of All Applicable Taxes. (2) Safety Cabinet For Corrosives General Specifications: - External Dimensions (w X D X H): 680-687 Mm X 700-705 X 2045-2055 Mm - Can Put At Least 4 Shelves - Shelf Capacity Per Volume Of Bottle: - Each Shelf Can Fit 9 Bottles With 2.5-4l Volume Capacity - Each Shelf Can Fit 12 Bottles With 2.0l Volume Capacity - Main Body Is Made Of Industrial-grade Electro-galvanized Steel - Shelves Are Made Of Polypropylene Material - Door Should Be Made With Powder-coated Electro-galvanized Steel With 6 Mm Thick Acrylic Window And A Lockable Swing Handle - With Voc Sensor And Alarm - Power Requirements: 220-240 Vac, 50-60 Hz, 1 Phase Power Supply - Uses A Microprocessor-based Control System - With Airflow Monitoring Via An Easy-to-read Lcd Panel Inclusion: - 1 Compatible Avr Per Unit - 1 Activated Carbon Filter Per Unit Features: - With Antimicrobial Powder Coating - With Door Safety Lock Terms And Conditions: 1. Supplier Shall Indicate Brand, Model, And Country Of Origin. 2. The Supplier Will Provide A Notarized Certificate Indicating That The Product Is Brand New, Not Reconditioned/refurbished Including Parts And Accessories. 3. Comes With Free Delivery To The Institute Of Pharmaceutical Sciences, National Institutes Of Health, Up Manila And Setup, Which Should Be Done Within 90-120 Days Upon Acceptance Of Notice To Proceed. Note That Acknowledgment By The Supplier Through Email Constitutes The Date Of Acceptance. 4. The Supplier Will Witness And Help Unpack The Equipment To Ensure That All Items Are Inside And In Good Condition. 5. Free Relocation And Re-setup Of Equipment If Requested By The End-user Within The University Of The Philippines Manila Area Within The Warranty Period With Subsequent Installation Qualification And Operational Qualification With Documentation And Report. 6. Qualified Service Engineer/s Must Perform Operational Qualification With Documentation And Report. 7. The Equipment Must Be Delivered And Ready To Use. Cables, Connectors, Adapters, And Accessories Even Not Specified But Are Essential For The Unit To Function Must Be Provided Free By The Winning Bidder. 8. Certification From The Manufacturer/local Distributor That In The Event Of A Change Of Local Distributor, Preventive Maintenance, Warranty, And Services Agreed Here Upon Will Be Honored By The Principal Manufacturer. 9. Certification Or Guarantee Letter From The Manufacturer/local Distributor To Ensure The Availability Of Parts, Supplies, And Accessories Will Not Be Discontinued For The Next 10 Years. 10. Undertaking To Provide Product Orientation And Operations Training For End-users And Troubleshooting Training For Research Staff Within Seven Days After Completion Of Installation. 11. Provide Free Preventive Maintenance And Calibration From The Distributor’s Qualified Engineer During The Warranty Period. 12. At Least A 1-year Warranty On Parts And Services. The Warranty Period Shall Commence From The Date Of Acceptance By The End-user, Testing, And Commissioning. 13. The Bidder Must Submit Certification That They Have The Capability For Corrective And Preventive Maintenance Of The Unit. 14. Availability Of Trained Service Engineers With Guaranteed Uptime Within 48 Hrs For Troubleshooting And Repair Of Unit Even After The Warranty Period. 15. Provide Operator’s And Service Manual (in English) Upon Delivery. 16. Price Should Be Inclusive Of All Applicable Taxes. (1) Multi-position Hotplate Stirrer General Specifications: - 6 Position Hotplate Stirrer - Independent Heat And Stirring Control For Each Plate - Heat Up To 380°c - Electronically Controlled Stirring From 60 To 150 Rpm - Durable Bearing Type Motor - Ceramic Coated Stainless Steel Top Plate - Each Plate Dimension Is 180 Mm X 180 Mm - Has An Anti-corrosive Powder-coated Steel Body - Uses An Electronic Solid-state Controller - Temperature Range: Ambient +5°c To 380°c - Motor Is Heavy Duty Bearing Operated Shaft - Electric Supply: 220v 50/60 Hz Inclusions: - Cylindrical Magnetic Stirring Bars Of Different Sizes: - 6 Pieces; Size Of Approximately 0.31 In. Diameter And 2 In. Length - 6 Pieces; Size Of Approximately 0.125 In. Diameter And 0.5 In. Length - 6 Pieces; Size Of Approximately 0.31 In. Diameter And 1.61 In. Length - 6 Pieces; Size Of Approximately 0.31 In. Diameter And 1 In. Length Terms And Conditions: 1. Supplier Shall Indicate Brand, Model, And Country Of Origin. 2. The Supplier Will Provide A Notarized Certificate Indicating That The Product Is Brand New, Not Reconditioned/refurbished Including Parts And Accessories. 3. Comes With Free Delivery To The Institute Of Pharmaceutical Sciences, National Institutes Of Health, Up Manila And Setup, Which Should Be Done Within 60-90 Days Upon Acceptance Of Notice To Proceed. Note That Acknowledgment By The Supplier Through Email Constitutes The Date Of Acceptance. 4. The Supplier Will Witness And Help Unpack The Equipment To Ensure That All Items Are Inside And In Good Condition. 5. Free Relocation And Re-setup Of Equipment If Requested By The End-user Within The University Of The Philippines Manila Area Within The Warranty Period With Subsequent Installation Qualification And Operational Qualification With Documentation And Report. 6. Qualified Service Engineer/s Must Perform Equipment Start-up, Testing, Operation, And/or Installation With Proper Documentation And Report. 7. The Equipment Must Be Delivered And Ready To Use. Cables, Connectors, Adapters, And Accessories Even Not Specified But Are Essential For The Unit To Function Must Be Provided Free By The Winning Bidder. 8. Certification From The Manufacturer/local Distributor That In The Event Of A Change Of Local Distributor, Preventive Maintenance, Warranty, And Services Agreed Here Upon Will Be Honored By The Principal Manufacturer. 9. Certification Or Guarantee Letter From The Manufacturer/local Distributor To Ensure The Availability Of Parts, Supplies, And Accessories Will Not Be Discontinued For The Next 10 Years. 10. Undertaking To Provide Product Orientation And Operations Training For End-users And Troubleshooting Training For Research Staff Within Seven Days After Completion Of Installation. 11. Provide Free Preventive Maintenance And Calibration From The Distributor’s Qualified Engineer During The Warranty Period. 12. At Least A 1-year Warranty On Parts Services. The Warranty Period Shall Commence From The Date Of Acceptance By The End-user, Testing, And Commissioning. 13. The Bidder Must Submit Certification That They Have The Capability For Corrective And Preventive Maintenance Of The Unit. 14. Availability Of Trained Service Engineers With Guaranteed Uptime Within 48 Hrs For Troubleshooting And Repair Of Unit Even After The Warranty Period. 15. Provide Operator’s And Service Manual (in English) Upon Delivery. 16. Price Should Be Inclusive Of All Applicable Taxes. (1) Emergency Response Kit General Specifications: - Contains A Portable Spill Kit And First Aid Kit - The Portable Spill Kit Should Include The Following Items Packed In A Reusable Bag With A Shoulder Strap - 32 Pcs Of 15 In. X 17-19 In. General Purpose Pads - 5 Pcs Of 3 In. X 4 Ft. Universal Socs - 1 Pc Of 18 In. X 18 In. Universal Absorbent Pillows - 1 Pair Of Nitrile Gloves - 2 Disposable Bags - 1 Pc Of Goggles - 1 Instruction Sheet - The First Aid Kit Should Include The Following Items Packed In A Bag With A Handle - Gauze Pad 3x3 Inches (at Least 2pcs) - Gauze Pad 4x4 Inches (at Least 2pcs) - Gauze Bandage 3x10 Inches - Elastic Bandage - Triangular Cotton Bandage - Facemask - Aluminum Whistle - Alcohol At Least 60 Ml - Adhesive Bandage Strip (at Least 10pcs) - Povidone Iodine Pads (at Least 4pcs) - Alcohol Applicator Pad (at Least 10pcs) - Povidone Applicator Stick (at Least 5pcs) - Rubber Tourniquet - Cpr Barrier - Thermal Blanket - Surgical Tape - Burn Ointment - Instant Ice Pack - Tweezers - At Least 10 Pcs Of Safety Pins - Pocket Flashlight - Scissors Terms And Conditions: 1. Supplier Shall Indicate Brand, Model, And Country Of Origin. 2. Supplier Will Provide A Notarized Certificate Indicating That The Items Included Are Brand New And Not Reconditioned/refurbished. 3. Comes With Free Delivery To The Institute Of Pharmaceutical Sciences, National Institutes Of Health, Up Manila Which Should Be Done Within 60-90 Days Upon Acceptance Of The Notice To Proceed. Note That Acknowledgment By The Supplier Through Email Constitutes The Date Of Acceptance. 4. The Supplier Will Help Unpack The Bags To Ensure That All Items Are Included Inside And Are In Good Condition. 5. Price Should Be Inclusive Of All Applicable Taxes. (1) Laboratory Water Bath General Specifications: - Dimensions (w X L X H) Are 68-72 X 33-37 X 24-28 Cm - Filling Volume Is Maximum Of 20l - Usable Immersion Depth Is Maximum Of 18 Cm - Bath Tank Is Made Of Stainless Steel - Usable Bath Opening Is At Least (w X L / D) Is 50 X 30 / 18 Cm Features: - Has Shaking Feature - Shaking Frequency (linear) Is 20 To 200 Rpm - Shaking Stroke Is At 15 To 25 Mm - Has Temperature Control - Uses Pid1 Microprocessor Temperature Control - Temperature Display Is Led - Has Keypad For Temperature Setting - Working Temperature Range Is At 20 To 100 °c - Temperature Stability Is At ±0.2 °c - Ambient Temperature Ranges From 5 To 40 °c - Splash-proof Design - Warning And Cut-off Protection For High/low Temperature - Comes With Bath Drains At The Bottom Portion Of The Unit - Electronic Timer For Setting The Running Time From 0:01 To 9:59 (h:min) - Has Removable Shaking Carriage - Provides Dry-running Protection With Audible And Optical Alarm - Has Removable Platform For Full Immersion Of The Sample Containers - Has Atc3 (absolute Temperature Calibration) 1-point-calibration - Has High-temperature Stability Inclusions: - Lift-up Cover - Basic Tray For Assembling Spring Clamps - Waterbath Protective Media 6 X 100 Ml Terms And Conditions: 1. Supplier Shall Indicate Brand, Model, And Country Of Origin. 2. The Supplier Will Provide A Notarized Certificate Indicating That The Product Is Brand New, Not Reconditioned/refurbished Including Parts And Accessories. 3. Comes With Free Delivery And Setup To The Institute Of Pharmaceutical Sciences, National Institutes Of Health, Up Manila Which Should Be Done Within 90-120 Days Upon Acceptance Of Notice To Proceed. Note That Acknowledgment By The Supplier Through Email Constitutes The Date Of Acceptance. 4. The Supplier Will Witness And Help Unpack The Equipment To Ensure That All Items Are Inside And In Good Condition. 5. Free Relocation And Re-setup Of Equipment If Requested By The End-user Within The University Of The Philippines Manila Area Within The Warranty Period With Subsequent Installation Qualification And Operational Qualification With Documentation And Report. 6. Qualified Service Engineer/s Must Perform Equipment Start-up, Testing, Operation, And/or Installation With Proper Documentation And Report. 7. The Equipment Must Be Delivered And Ready To Use. Cables, Connectors, Adapters, And Accessories Even Not Specified But Are Essential For The Unit To Function Must Be Provided Free By The Winning Bidder. 8. Certification From The Manufacturer/local Distributor That In The Event Of A Change Of Local Distributor, Preventive Maintenance, Warranty, And Services Agreed Here Upon Will Be Honored By The Principal Manufacturer. 9. Certification Or Guarantee Letter From The Manufacturer/local Distributor To Ensure The Availability Of Parts, Supplies, And Accessories Will Not Be Discontinued For The Next 10 Years. 10. Undertaking To Provide Product Orientation And Operations Training For End-users And Troubleshooting Training For Research Staff Within Seven Days After Completion Of Installation. 11. Provide Free Preventive Maintenance And Calibration From The Distributor’s Qualified Engineer During The Warranty Period. 12. At Least A 1-year Warranty On Parts And Services. The Warranty Period Shall Commence From The Date Of Acceptance By The End-user, Testing, And Commissioning. 13. The Bidder Must Submit Certification That They Have The Capability For Corrective And Preventive Maintenance Of The Unit. 14. Availability Of Trained Service Engineers With Guaranteed Uptime Within 48 Hrs For Troubleshooting And Repair Of Unit Even After The Warranty Period. 15. Provide Operator’s And Service Manual (in English) Upon Delivery. 16. Price Should Be Inclusive Of All Applicable Taxes. (1) Vortex Mixer And Accessories General Specifications: - Mixing Frequency Ranges From 300-3000 Rpm - Dimensions (w X D X H) Should Be Less Than 17 X 23 X 13 Cm - Weighs Less Than 8 Kg - Ø Of Mixing Orbit Is 3 Mm - Has A Timer That Ranges From 15 Sec To 99:30 Hours And Capable Of Continuous Mode - Has Mix Control, Anti-spill Technology, And Touch Vortexing Mode Accessories Included: - Compatible Holder For 1.5 Ml Microtubes - Compatible Holder For 15 Ml Conical Tubes Terms And Conditions: 1. Supplier Shall Indicate Brand, Model, And Country Of Origin. 2. The Supplier Will Provide A Notarized Certificate Indicating That The Product Is Brand New, Not Reconditioned/refurbished Including Parts And Accessories. 3. Comes With Free Delivery And Setup To The Institute Of Pharmaceutical Sciences, National Institutes Of Health, Up Manila Which Should Be Done Within 60-90 Days Upon Acceptance Of Notice To Proceed. Note That Acknowledgment By The Supplier Through Email Constitutes The Date Of Acceptance. 4. The Supplier Will Witness And Help Unpack The Equipment To Ensure That All Items Are Inside And In Good Condition. 5. Free Relocation And Re-setup Of Equipment If Requested By The End-user Within The University Of The Philippines Manila Area Within The Warranty Period With Subsequent Installation Qualification And Operational Qualification With Documentation And Report. 6. Qualified Service Engineer/s Must Perform Equipment Start-up, Testing, Operation, And/or Installation With Proper Documentation And Report. 7. The Equipment Must Be Delivered And Ready To Use. Cables, Connectors, Adapters, And Accessories Even Not Specified But Are Essential For The Unit To Function Must Be Provided Free By The Winning Bidder. 8. Certification From The Manufacturer/local Distributor That In The Event Of A Change Of Local Distributor, Preventive Maintenance, Warranty, And Services Agreed Here Upon Will Be Honored By The Principal Manufacturer. 9. Certification Or Guarantee Letter From The Manufacturer/local Distributor To Ensure The Availability Of Parts, Supplies, And Accessories Will Not Be Discontinued For The Next 10 Years. 10. Undertaking To Provide Product Orientation And Operations Training For End-users And Troubleshooting Training For Research Staff Within Seven Days After Completion Of Installation. 11. Provide Free Preventive Maintenance And Calibration From The Distributor’s Qualified Engineer During The Warranty Period. 12. At Least A 1-year Warranty On Parts And Services. The Warranty Period Shall Commence From The Date Of Acceptance By The End-user, Testing, And Commissioning. 13. The Bidder Must Submit Certification That They Have The Capability For Corrective And Preventive Maintenance Of The Unit. 14. Availability Of Trained Service Engineers With Guaranteed Uptime Within 48 Hrs For Troubleshooting And Repair Of Unit Even After The Warranty Period. 15. Provide Operator’s And Service Manual (in English) Upon Delivery. 16. Price Should Be Inclusive Of All Applicable Taxes. (1) Ultrasonic Waterbath General Specifications: - Tank Capacity Is At Least 9.5 L With The Following Dimensions (l X W X D) 11-13 X 9-11 X 5-7 Inches - Overall Size Of The Equipment Should Be Around (l X W X D) 15-17 X 15-17 X 14-16 Inches - Frequency Should Be At 40 Khz - Needs To Have A Drain - Comes With A Cover - Has 40 Khz Rugged Industrial Transducers With Sweep Frequency - With Heater That Heat Up To 69°c - Has A Dual Power And Power Tracking - Has A Sleep Mode - Capable Of Degas Wave Modulation And Auto Ultrasonics Activation - Has High-temperature Alarm - Front Panel Auto Temp Calibration - Body Is Made Of Chemical-resistant Plastic Inclusions: - Compatible Perforated Tray - Compatible Solid Insert Tray Terms And Conditions: 1. Supplier Shall Indicate Brand, Model, And Country Of Origin. 2. Supplier Will Provide A Notarized Certificate Indicating That The Product Is Brand New, Not Reconditioned/refurbished Including Parts And Accessories. 3. Comes With Free Delivery And Setup To The Institute Of Pharmaceutical Sciences, National Institutes Of Health, Up Manila Which Should Be Done Within 60-90 Days Upon Acceptance Of Notice To Proceed. Note That Acknowledgment By The Supplier Through Email Constitutes The Date Of Acceptance. 4. The Supplier Will Witness And Help Unpack The Equipment To Ensure That All Items Are Inside And In Good Condition. 5. Free Relocation And Re-setup Of Equipment If Requested By The End-user Within The University Of The Philippines Manila Area Within The Warranty Period With Subsequent Installation Qualification And Operational Qualification With Documentation And Report. 6. Qualified Service Engineer/s Must Perform Equipment Start-up, Testing, Operation, And/or Installation With Proper Documentation And Report. 7. The Equipment Must Be Delivered Ready To Use. Cables, Connectors, Adapters, And Accessories Even Not Specified But Are Essential For The Unit To Function Must Be Provided Free By The Winning Bidder. 8. Certification From The Manufacturer/local Distributor That In The Event Of A Change Of Local Distributor, Preventive Maintenance, Warranty, And Services Agreed Here Upon Will Be Honored By The Principal Manufacturer. 9. Certification Or Guarantee Letter From The Manufacturer/local Distributor To Ensure The Availability Of Parts, Supplies, And Accessories And Will Not Be Discontinued For The Next 10 Years. 10. Undertaking To Provide Product Orientation And Operations Training For End-users And Troubleshooting Training For Research Staff Within Seven Days After Completion Of Installation. 11. Provide Free Preventive Maintenance And Calibration From The Distributor’s Qualified Engineer During The Warranty Period. 12. At Least A 1-year Warranty On Parts And Services. The Warranty Period Shall Commence From The Date Of Acceptance By The End-user, Testing, And Commissioning. 13. The Bidder Must Submit Certification That They Have The Capability For Corrective And Preventive Maintenance Of The Unit. 14. Availability Of Trained Service Engineers With Guaranteed Uptime Within 48 Hrs For Troubleshooting And Repair Of Unit Even After The Warranty Period. 15. Provide Operator’s And Service Manual (in English) Upon Delivery. 16. Price Should Be Inclusive Of All Applicable Taxes. (1) Automated Solid Phase Extraction Manifold General Specifications: - Gas Regulator And Gas Gauge Range: - Output: 0-30 Psi - Input: 100 Psi Maximum - Dimensions (hxwxd): 20-23 X 22-25 X 25-27 In - Sample Rack Dimensions (hxwxd): 6-8 X 16-18 X 10-13 In - With Operating System Software With 24 Default Methods Stored In The Software - Liquid Management - Air Syringe: One 10 Ml Air Syringe - Lh Syringe: One 10 Ml Liquid Handling Syringe - 12 - 24 Port Rotary Valve With Sliding Seal - Stainless Steel Nozzle - With 12 Or More Sample Inlet And Are Made Of Ptfe Tubing, 1/16” Id - Sample Pumps - Has Positive Displacement - Accuracy Is At +/- 2.5% - Ceramic Piston And Liner - Non Use Of Acetic Acid, Acetone - Has Various Spe Configurations - 1 Ml Syringe: Compatible Cartridges (reversed Phase Preferably C18) - 3 Ml Syringe: Compatible Cartridges (reversed Phase Preferably C18) - 6 Ml Syringe: Compatible Cartridges (reversed Phase Preferably C18) - Disk Version: 47 Mm Spe Disk (reversed Phase Preferably C18) Features: - Automates Sample Loading Of Liquids Onto Spe Cartridges - Automates Eluting Of Spe Cartridges With Organic Solvent - Has Closed Systems With Fan To Vent Solvent Vapors - Spe Technology For Liquid-liquid Extraction - Uses Positive Pressure Loading And Elution Of Samples And Solvents Terms And Conditions: 1. Supplier Shall Indicate Brand, Model, And Country Of Origin. 2. The Supplier Will Provide A Notarized Certificate Indicating That The Product Is Brand New, Not Reconditioned/refurbished Including Parts And Accessories. 3. Comes With Free Delivery And Setup To The Institute Of Pharmaceutical Sciences, National Institutes Of Health, Up Manila Which Should Be Done Within 60-90 Days Upon Acceptance Of Notice To Proceed. Note That Acknowledgment By The Supplier Through Email Constitutes The Date Of Acceptance. 4. The Supplier Will Witness And/or Help Unpack The Equipment To Ensure That All Items Are Inside And In Good Condition. 5. Free Relocation And Re-setup Of Equipment If Requested By The End-user Within The University Of The Philippines Manila Area Within The Warranty Period With Subsequent Installation Qualification And Operational Qualification With Documentation And Report. 6. Qualified Service Engineer/s Must Perform Equipment Start-up, Testing, Operation, And/or Installation With Proper Documentation And Report. 7. The Equipment Must Be Delivered Ready To Use. Cables, Connectors, Adapters, And Accessories Even Not Specified But Are Essential For The Unit To Function Must Be Provided Free By The Winning Bidder. 8. Certification From The Manufacturer/local Distributor That In The Event Of A Change Of Local Distributor, Preventive Maintenance, Warranty, And Services Agreed Here Upon Will Be Honored By The Principal Manufacturer. 9. Certification Or Guarantee Letter From The Manufacturer/local Distributor To Ensure The Availability Of Parts, Supplies, And Accessories And Will Not Be Discontinued For The Next 10 Years. 10. Undertaking To Provide Product Orientation And Operations Training For End-users And Troubleshooting Training For Research Staff Within Seven Days After Completion Of Installation. 11. Provide Free Preventive Maintenance And Calibration From The Distributor’s Qualified Engineer During The Warranty Period. 12. At Least A 1-year Warranty On Parts And Services. The Warranty Period Shall Commence From The Date Of Acceptance By The End-user, Testing, And Commissioning. 13. The Bidder Must Submit Certification That They Have The Capability For Corrective And Preventive Maintenance Of The Unit. 14. Availability Of Trained Service Engineers With Guaranteed Uptime Within 48 Hrs For Troubleshooting And Repair Of Unit Even After The Warranty Period. 15. Provide Operator’s And Service Manual (in English) Upon Delivery. 16. Price Should Be Inclusive Of All Applicable Taxes.
Contact
Tender Id
48e262af-607b-3978-bb0b-a1ada9039fe8Tender No
11454481Tender Authority
University Of The Philippines ViewPurchaser Address
-Website
https://www.up.edu.ph/