University Of The Philippines Tender
University Of The Philippines Tender
Costs
Summary
Supply Of Various Laboratory Equipment For The Project, Project 2: Establishment Of Pharmaceutical Sciences Services For Clinical Research , Laboratory Supplies And Equipment ,university Of The Philippines - Manila
Description
Description Supply Of Various Laboratory Equipment For The Project, Project 2: Establishment Of Pharmaceutical Sciences Services For Clinical Research Chemical Storage Cabinet General Specifications: - Internal Volume: 440 To 450 L - Dimensions Interior (w X D X H): 20-22 X 17-19 X 66-68 Inches - Dimensions Exterior (w X D X H): 24-26 X 20-22 X 73-75 Inches - Can Put 3 To 6 Shelves Inside - Can Put 4 To 7 Trays Inside - Maximum Load Per Shelf Is 50 Kg Or More - Made With Corrosion-resistant Interior Material - With Built-in Ventilation Hole - Compatible With Extraction Module As Filter Inclusions: - 3 Shelves - 4 Corrosion-resistant Pp Trays - 1 Extraction Module Terms And Conditions: 1. Supplier Shall Indicate Brand, Model, And Country Of Origin. 2. The Supplier Will Provide A Notarized Certificate Indicating That The Product Is Brand New, Not Reconditioned/refurbished Including Parts And Accessories. 3. Comes With Free Delivery To The Institute Of Pharmaceutical Sciences, National Institutes Of Health, Up Manila And Setup, Which Should Be Done Within 90-120 Days Upon Acceptance Of Notice To Proceed. Note That Acknowledgment By The Supplier Through Email Constitutes The Date Of Acceptance. 4. The Supplier Will Witness And Help The Unpacking Of The Equipment To Ensure That All Items Are Included Inside And In Good Condition. 5. Free Relocation And Re-setup Of Equipment If Requested By The End-user Within The University Of The Philippines Manila Area Within The Warranty Period With Subsequent Installation Qualification And Operational Qualification With Documentation And Report. 6. Qualified Service Engineer/s Must Perform Operational Qualification With Documentation And Report. 7. The Equipment Must Be Delivered And Ready To Use. Cables, Connectors, Adapters, And Accessories Even Not Specified But Are Essential For The Unit To Function Must Be Provided Free By The Winning Bidder. 8. Certification From The Manufacturer/local Distributor That In The Event Of A Change Of Local Distributor, Preventive Maintenance, Warranty, And Services Agreed Here Upon Will Be Honored By The Principal Manufacturer. 9. Certification Or Guarantee Letter From The Manufacturer/local Distributor To Ensure The Availability Of Parts, Supplies, And Accessories Will Not Be Discontinued For The Next 10 Years. 10. Undertaking To Provide Product Orientation And Operations Training For End-users And Troubleshooting Training For Research Staff Within Seven Days After Completion Of Installation. 11. Provide Bi-annual Preventive Maintenance And Calibration From The Distributor’s Qualified Engineer During The Warranty Period. 12. At Least A 2-year Warranty On Parts And Services. The Warranty Period Shall Commence From The Date Of Acceptance By The End-user, Testing, And Commissioning. 13. The Bidder Must Submit Certification That They Have The Capability For Corrective And Preventive Maintenance Of The Unit. 14. Availability Of Trained Service Engineers With Guaranteed Uptime Within 48 Hrs For Troubleshooting And Repair Of Unit Even After The Warranty Period. 15. Provide Operator’s And Service Manual (in English) Upon Delivery. 16. Price Should Be Inclusive Of All Applicable Taxes. Safety Cabinet For Corrosives General Specifications: - External Dimensions (w X D X H): 680-687 Mm X 700-705 X 2045-2055 Mm - Can Put 4 Trays Per Section - Tray Capacity Per Volume Of Bottle: - Each Tray Can Fit 9 Bottles With 2.5-4l Volume Capacity - Each Tray Can Fit 12 Bottles With 2.0l Volume Capacity - Main Body Is Made Of Industrial-grade Electro-galvanized Steel - Trays Are Made Of Polypropylene Material - Door Should Be Made With Powder-coated Electro-galvanized Steel With 6 Mm Thick Acrylic Window And A Lockable Swing Handle - With Voc Sensor And Alarm - Power Requirements: 220-240 Vac, 50-60 Hz, 1 Phase Power Supply - Uses A Microprocessor-based Control System - With Airflow Monitoring Via An Easy-to-read Lcd Panel Inclusion: - 1 Compatible Avr Per Unit - 1 Activated Carbon Filter Per Unit Features: - Has Dual Filtration System (main Filter Uses Activated Carbon Filter And Secondary Filter Is Hepa Filter) - With Antimicrobial Powder Coating - With Door Safety Lock Terms And Conditions: 1. Supplier Shall Indicate Brand, Model, And Country Of Origin. 2. The Supplier Will Provide A Notarized Certificate Indicating That The Product Is Brand New, Not Reconditioned/refurbished Including Parts And Accessories. 3. Comes With Free Delivery To The Institute Of Pharmaceutical Sciences, National Institutes Of Health, Up Manila And Setup, Which Should Be Done Within 90-120 Days Upon Acceptance Of Notice To Proceed. Note That Acknowledgment By The Supplier Through Email Constitutes The Date Of Acceptance. 4. The Supplier Will Witness And Help The Unpacking Of The Equipment To Ensure That All Items Are Included Inside And In Good Condition. 5. Free Relocation And Re-setup Of Equipment If Requested By The End-user Within The University Of The Philippines Manila Area Within The Warranty Period With Subsequent Installation Qualification And Operational Qualification With Documentation And Report. 6. Qualified Service Engineer/s Must Perform Operational Qualification With Documentation And Report. 7. The Equipment Must Be Delivered And Ready To Use. Cables, Connectors, Adapters, And Accessories Even Not Specified But Are Essential For The Unit To Function Must Be Provided Free By The Winning Bidder. 8. Certification From The Manufacturer/local Distributor That In The Event Of A Change Of Local Distributor, Preventive Maintenance, Warranty, And Services Agreed Here Upon Will Be Honored By The Principal Manufacturer. 9. Certification Or Guarantee Letter From The Manufacturer/local Distributor To Ensure The Availability Of Parts, Supplies, And Accessories Will Not Be Discontinued For The Next 10 Years. 10. Undertaking To Provide Product Orientation And Operations Training For End-users And Troubleshooting Training For Research Staff Within Seven Days After Completion Of Installation. Multi-position Hotplate Stirrer General Specifications: - 6 Position Hotplate Stirrer - Independent Heat And Stirring Control For Each Plate - Heat Up To 380°c - Electronically Controlled Stirring From 60 To 150 Rpm - Durable Bearing Type Motor - Ceramic Coated Stainless Steel Top Plate - Each Plate Dimension Is 180 Mm X 180 Mm - Has Anti-corrosive Powder-coated Steel Body - Uses An Electronic Solid-state Controller - Temperature Range: Ambient +5°c To 380°c - Motor Is Heavy Duty Bearing Operated Shaft - Electric Supply: 220v 50/60 Hz Inclusions: - Cylindrical Magnetic Stirring Bars Of Different Sizes: - 6 Pieces; Size Of Approximately 0.31 In. Diameter And 2 In. Length - 6 Pieces; Size Of Approximately 0.125 In. Diameter And 0.5 In. Length - 6 Pieces; Size Of Approximately 0.31 In. Diameter And 1.61 In. Length - 6 Pieces; Size Of Approximately 0.31 In. Diameter And 1 In. Length Terms And Conditions: 1. Supplier Shall Indicate Brand, Model, And Country Of Origin. 2. The Supplier Will Provide A Notarized Certificate Indicating That The Product Is Brand New, Not Reconditioned/refurbished Including Parts And Accessories. 3. Comes With Free Delivery To The Institute Of Pharmaceutical Sciences, National Institutes Of Health, Up Manila And Setup, Which Should Be Done Within 60-90 Days Upon Acceptance Of Notice To Proceed. Note That Acknowledgment By The Supplier Through Email Constitutes The Date Of Acceptance. 4. The Supplier Will Witness And Help The Unpacking Of The Equipment To Ensure That All Items Are Included Inside And In Good Condition. 5. Free Relocation And Re-setup Of Equipment If Requested By The End-user Within The University Of The Philippines Manila Area Within The Warranty Period With Subsequent Installation Qualification And Operational Qualification With Documentation And Report. 6. Qualified Service Engineer/s Must Perform Equipment Start-up, Testing, Operation, And/or Installation With Proper Documentation And Report. 7. The Equipment Must Be Delivered And Ready To Use. Cables, Connectors, Adapters, And Accessories Even Not Specified But Are Essential For The Unit To Function Must Be Provided Free By The Winning Bidder. 8. Certification From The Manufacturer/local Distributor That In The Event Of A Change Of Local Distributor, Preventive Maintenance, Warranty, And Services Agreed Here Upon Will Be Honored By The Principal Manufacturer. 9. Certification Or Guarantee Letter From The Manufacturer/local Distributor To Ensure The Availability Of Parts, Supplies, And Accessories Will Not Be Discontinued For The Next 10 Years. 10. Undertaking To Provide Product Orientation And Operations Training For End-users And Troubleshooting Training For Research Staff Within Seven Days After Completion Of Installation. 11. Provide Bi-annual Preventive Maintenance And Calibration From The Distributor’s Qualified Engineer During The Warranty Period. 12. At Least A 2-year Warranty On Parts And Services. The Warranty Period Shall Commence From The Date Of Acceptance By The End-user, Testing, And Commissioning. 13. The Bidder Must Submit Certification That They Have The Capability For Corrective And Preventive Maintenance Of The Unit. 14. Availability Of Trained Service Engineers With Guaranteed Uptime Within 48 Hrs For Troubleshooting And Repair Of Unit Even After The Warranty Period. 15. Provide Operator’s And Service Manual (in English) Upon Delivery. Price Should Be Inclusive Of All Applicable Taxes 11. Provide Bi-annual Preventive Maintenance And Calibration From The Distributor’s Qualified Engineer During The Warranty Period. 12. At Least A 2-year Warranty On Parts And Services. The Warranty Period Shall Commence From The Date Of Acceptance By The End-user, Testing, And Commissioning. 13. The Bidder Must Submit Certification That They Have The Capability For Corrective And Preventive Maintenance Of The Unit. 14. Availability Of Trained Service Engineers With Guaranteed Uptime Within 48 Hrs For Troubleshooting And Repair Of Unit Even After The Warranty Period. 15. Provide Operator’s And Service Manual (in English) Upon Delivery. 16. Price Should Be Inclusive Of All Applicable Taxes. Ultralow Freezer General Specifications: - External Dimensions (w X D X H): 665-675 X 878-885 X 1835-1845 Mm - Internal Dimensions (w X D X H): 485-495 X 595-605 X 1225-1235 Mm - With Total Capacity Of 360 Liters Or More - Temperature Control Range Is From -50 To -86°c In 1° Increments - Has A Microprocessor Controller With Non-volatile Memory - Has Lcd Touch Screen Display - Uses Pt-1000 As Temperature Sensor - Has Independent Dual-cooling Refrigeration System With 2 Compressors At 1100 W - Uses Hfc Mixed Refrigerant - Uses Puf/vip Plus As Insulation Material With 80 Mm Thickness - Has 1 Outer Door With Lock - Has 2 Inner Doors - Has 3 Stainless Steel Shelves Inside With A Maximum Load Of 50 Kg - With 2 Vacuum Release Ports (1 Automatic, 1 Manual) - With 3 Access Ports: 1 At The Back And 2 At The Bottom - Has 4 Casters (with 2 Leveling Feet) - Has Visual, Buzzer, And Remote Alarm For Power Failure, High Temperature, And Low Temperature - Has Visual And Buzzer Alarm If Door Left Open - Filterless Design - Power Supply: 230v - Noise Level: 50 Dba Inclusions: - Compatible Avr - Compatible Liquid Co2 Back-up (with Filled Tank) - Cryosafety Gloves - Ice Scraper Terms And Conditions: 1. Supplier Shall Indicate Brand, Model, And Country Of Origin. 2. The Supplier Will Provide A Notarized Certificate Indicating That The Product Is Brand New, Not Reconditioned/refurbished Including Parts And Accessories. 3. Comes With Free Delivery And Installation, Which Should Be Done Within 90-120 Days Upon Acceptance Of Notice To Proceed. Note That Acknowledgment By The Supplier Through Email Constitutes The Date Of Acceptance. 4. The Supplier Will Witness And Help The Unpacking Of The Equipment To Ensure That All Items Are Included Inside And In Good Condition. 5. Free Relocation And Re-setup Of Equipment If Requested By The End-user Within The University Of The Philippines Manila Area Within The Warranty Period With Subsequent Installation Qualification And Operational Qualification With Documentation And Report. 6. Qualified Service Engineer/s Must Perform Installation Qualification And Operational Qualification With Documentation And Report. 7. The Equipment Must Be Delivered And Ready To Use. Cables, Connectors, Adapters, And Accessories Even Not Specified But Are Essential For The Unit To Function Must Be Provided Free By The Winning Bidder. 8. Certification From The Manufacturer/local Distributor That In The Event Of A Change Of Local Distributor, Preventive Maintenance, Warranty, And Services Agreed Here Upon Will Be Honored By The Principal Manufacturer. 9. Certification Or Guarantee Letter From The Manufacturer/local Distributor To Ensure The Availability Of Parts, Supplies, And Accessories Will Not Be Discontinued For The Next 10 Years. 10. Undertaking To Provide Product Orientation And Operations Training For End-users And Troubleshooting Training For Research Staff Within Seven Days After Completion Of Installation. 11. Provide Bi-annual Preventive Maintenance And Calibration From The Distributor’s Qualified Engineer During The Warranty Period. 12. At Least A 2-year Warranty On Parts And Services. The Warranty Period Shall Commence From The Date Of Acceptance By The End-user, Testing, And Commissioning. 13. The Bidder Must Submit Certification That They Have The Capability For Corrective And Preventive Maintenance Of The Unit. 14. Availability Of Trained Service Engineers With Guaranteed Uptime Within 48 Hrs For Troubleshooting And Repair Of Unit Even After The Warranty Period. 15. Provide Operator’s And Service Manual (in English) Upon Delivery. 16. Price Should Be Inclusive Of All Applicable Taxes. Safety Shower And Eyewash General Specifications: - Eyewash Bowl And Shower Head Diameter: 255-265 Mm - Dimensions Of Assembled Station: 295-305 Mm X 845-855 Mm X 2375-2385 Mm - Pipe Wall Thickness: ~2.5 Mm - Work Pressure: 0.2~0.6 Mpa (2~6 Bar) - Eye Wash Flow: >11.4l/min (3 Us Gallon) - Shower Flow: >75.7l/min (20 Us Gallon) - Working Temperature Range From 5-35°c - Shower Should Be Operated Using A Pull Rod Lever - Eyewash Should Be Operated Using A Flag Handle Switch Valve And/or Foot Pedal Switch Valve - Floor Mounted Using Expansion Bolt - All Parts Should Be Made From High-quality 304 Stainless Steel (except For Eyewash That Can Include Abs Plastic) - With 12-month Rust-free Warranty - Should Be Ansi Z358.1-2014 (us Standard) Certified Terms And Conditions: 1. Supplier Shall Indicate Brand, Model, And Country Of Origin. 2. The Supplier Will Provide A Notarized Certificate Indicating That The Product Is Brand New, Not Reconditioned/refurbished Including Parts And Accessories. 3. Comes With Free Delivery And Installation To The Institute Of Pharmaceutical Sciences, National Institutes Of Health, Up Manila Which Should Be Done Within 90-120 Days Upon Acceptance Of Notice To Proceed. Note That Acknowledgment By The Supplier Through Email Constitutes The Date Of Acceptance. 4. The Supplier Will Witness And Help The Unpacking Of The Equipment To Ensure That All Items Are Included Inside And In Good Condition. 5. Free Relocation And Re-setup Of Equipment If Requested By The End-user Within The University Of The Philippines Manila Area Within The Warranty Period With Subsequent Installation Qualification And Operational Qualification With Documentation And Report. 6. Qualified Service Engineer/s Must Perform Installation Qualification And Operational Qualification With Documentation And Report. 7. The Equipment Must Be Delivered And Ready To Use. Accessories Not Specified But Are Essential For The Unit To Function Must Be Provided Free By The Winning Bidder. 8. Certification From The Manufacturer/local Distributor That In The Event Of A Change Of Local Distributor, Preventive Maintenance, Warranty, And Services Agreed Here Upon Will Be Honored By The Principal Manufacturer. 9. Certification Or Guarantee Letter From The Manufacturer/local Distributor To Ensure The Availability Of Parts, Supplies, And Accessories Will Not Be Discontinued For The Next 10 Years. 10. Undertaking To Provide Product Orientation And Operations Training For End-users And Troubleshooting Training For Research Staff Within Seven Days After Completion Of Installation. 11. Provide Bi-annual Preventive Maintenance And Calibration From The Distributor’s Qualified Engineer During The Warranty Period. 12. At Least A 2-year Warranty On Parts And Services. The Warranty Period Shall Commence From The Date Of Acceptance By The End-user, Testing, And Commissioning. 13. The Bidder Must Submit Certification That They Have The Capability For Corrective And Preventive Maintenance Of The Unit. 14. Availability Of Trained Service Engineers With Guaranteed Uptime Within 48 Hrs For Troubleshooting And Repair Of Unit Even After The Warranty Period. 15. Provide Operator’s And Service Manual (in English) Upon Delivery. 16. Price Should Be Inclusive Of All Applicable Taxes. Nitrogen Evaporation System General Specifications: - Ambient Temperature Range Is From +5°c To 120°c - Microprocessor Digital Pid For Temperature Control With Increments Of 0.1°c - Has Heating Temperature Method - With Touch Buttons And Led Display For Operating Panel - Manifold Size (w X D X H): 128-132 X 108-112 X 28-32 Mm - Flow Rate For Each Nozzle Control (20ea) - Has A Pinion Motion Stand - With Flow Control Valve To Serve As Connecting Port - Block Capacity: 2 Blocks (bl X 2ea) - Block Dimensions (w X D X H) Is 108-112 X88- 92 X 43-47 Mm - Overall Dimensions (w X D X H): 308-312 X248-252 X 433-437 Mm - Each Nozzle Exhaust System Should Be Contamination Free Inclusions: - 2 Blocks Of 1.5 Ml Microtube X 20 Holes With Ø11 Mm - 2 Blocks Of 10 Ml Tube X 20 Holes With Ø13 Mm - 2 Blocks Of 15 Ml Tube X 20 Holes With Ø16 Mm - 1 Filled Nitrogen Tank With Appropriate Connectors Terms And Conditions: 1. Supplier Shall Indicate Brand, Model, And Country Of Origin. 2. The Supplier Will Provide A Notarized Certificate Indicating That The Product Is Brand New, Not Reconditioned/refurbished Including Parts And Accessories. 3. Comes With Free Delivery And Setup To The Institute Of Pharmaceutical Sciences, National Institutes Of Health, Up Manila Which Should Be Done Within 60-90 Days Upon Acceptance Of Notice To Proceed. Note That Acknowledgment By The Supplier Through Email Constitutes The Date Of Acceptance. 4. The Supplier Will Witness And Help The Unpacking Of The Equipment To Ensure That All Items Are Included Inside And In Good Condition. 5. Free Relocation And Re-setup Of Equipment If Requested By The End-user Within The University Of The Philippines Manila Area Within The Warranty Period With Subsequent Installation Qualification And Operational Qualification With Documentation And Report. 6. Qualified Service Engineer/s Must Perform Equipment Start-up, Testing, Operation, And/or Installation With Proper Documentation And Report. 7. The Equipment Must Be Delivered And Ready To Use. Cables, Connectors, Adapters, And Accessories Even Not Specified But Are Essential For The Unit To Function Must Be Provided Free By The Winning Bidder. 8. Certification From The Manufacturer/local Distributor That In The Event Of A Change Of Local Distributor, Preventive Maintenance, Warranty, And Services Agreed Here Upon Will Be Honored By The Principal Manufacturer. 9. Certification Or Guarantee Letter From The Manufacturer/local Distributor To Ensure The Availability Of Parts, Supplies, And Accessories Will Not Be Discontinued For The Next 10 Years. 10. Undertaking To Provide Product Orientation And Operations Training For End-users And Troubleshooting Training For Research Staff Within Seven Days After Completion Of Installation. 11. Provide Bi-annual Preventive Maintenance And Calibration From The Distributor’s Qualified Engineer During The Warranty Period. 12. At Least A 2-year Warranty On Parts And Services. The Warranty Period Shall Commence From The Date Of Acceptance By The End-user, Testing, And Commissioning. 13. The Bidder Must Submit Certification That They Have The Capability For Corrective And Preventive Maintenance Of The Unit. 14. Availability Of Trained Service Engineers With Guaranteed Uptime Within 48 Hrs For Troubleshooting And Repair Of Unit Even After The Warranty Period. 15. Provide Operator’s And Service Manual (in English) Upon Delivery. 16. Price Should Be Inclusive Of All Applicable Taxes. Hot Wire Anemometer With Sd Card Logger General Specifications: - Can Read The Following Units Of Measurements: - Ft/min: 40 To 3940 - Km/h: 0.4 To 38.8 - Mph: 0.2 To 25.0 - Knots: 0.7 To 72.0 - M/s: 0.5 To 44.7 - Type K: -50 To 1300°c - Type J: -50 To 1100°c - Air Temp: 0 To 5°c - Handheld Size But With Comes With A Fold-out Tripod - With Low Battery Indicator - With Hold Function - Has Auto Power Off Feature - With Backlit Lcd Inclusions: - Soft Carrying Case - Detachable Probe - 6 Aa Batteries - Instruction Manual - Sd Card With 32 Gb Memory Or More Terms And Conditions: 1. Supplier Shall Indicate Brand, Model, And Country Of Origin. 2. The Supplier Will Provide A Notarized Certificate Indicating That The Product Is Brand New, Not Reconditioned/refurbished Including Parts And Accessories. 3. Comes With Free Delivery To The Institute Of Pharmaceutical Sciences, National Institutes Of Health, Up Manila Which Should Be Done Within 60-90 Days Upon Acceptance Of Notice To Proceed. Note That Acknowledgment By The Supplier Through Email Constitutes The Date Of Acceptance. 4. The Supplier Will Witness And/or Help The Unpacking Of The Equipment To Ensure That All Items Are Included Inside And In Good Condition. 5. Qualified Service Engineer/s Must Perform Equipment Start-up, Testing, Operation, And/or Installation With Proper Documentation And Report. 6. The Equipment Must Be Delivered And Ready To Use. Connectors, Adapters, And/or Accessories Even Not Specified But Are Essential For The Unit To Function Must Be Provided Free By The Winning Bidder. 7. Certification From The Manufacturer/local Distributor That In The Event Of A Change Of Local Distributor, Preventive Maintenance, Warranty, And Services Agreed Here Upon Will Be Honored By The Principal Manufacturer. 8. Certification Or Guarantee Letter From The Manufacturer/local Distributor To Ensure The Availability Of Parts, Supplies, And Accessories Will Not Be Discontinued For The Next 10 Years. 9. Undertaking To Provide Product Orientation And Operations Training For End-users And Troubleshooting Training For Research Staff Within Seven Days After Completion Of Installation. 10. Provide Bi-annual Preventive Maintenance And Calibration From The Distributor’s Qualified Engineer During The Warranty Period. 11. At Least A 2-year Warranty On Parts And Services. The Warranty Period Shall Commence From The Date Of Acceptance By The End-user, Testing, And Commissioning. 12. The Bidder Must Submit Certification That They Have The Capability For Corrective And Preventive Maintenance Of The Unit. 13. Availability Of Trained Service Engineers With Guaranteed Uptime Within 48 Hrs For Troubleshooting And Repair Of Unit Even After The Warranty Period. 14. Provide Operator’s And Service Manual (in English) Upon Delivery. 15. Price Should Be Inclusive Of All Applicable Taxes. Refrigerated Centrifuge General Specifications: - Speed - Maximum Speed Is 18,000 Rpm (in 100-rpm Increments) - Maximum G-force Is 29,000 X G Or Higher - Actual Rotor Speed Should Only Be ± 50 Rpm Of Set Speed - Displayed Speed Should Be Actual Rotor Speed In 100-rpm Increments Or In Rcf - Time - Can Set Time Up To To 9:59 (h:min) Or Set In Continuous Mod - Has Hold And Pulse (short Run) Options - Time Is Either Displayed– Time Remaining In Run (timed Run ± 1 Min Accuracy) Or ∞ And Elapsed Time (continuous Run) - Temperature - Temperature Can Be Set From -20 To +40°c (in 1°c Increments) - Temperature Control (after Equilibration) Is At ± 2.5°c Of Set Temperature - Temperature Display (after Equilibration) – Chamber Temperature In 1°c Increments - Operating Range Is From 2 To 40°c - Ambient Temperature Range Is From 10 To 35°c - With Cfc-free Refrigeration System - Has 10 Acceleration And Deceleration Profiles - Mechanical And Electrical Requirements - Unit Should Weigh <80 Kg - Requires A Maximum Of 3 In. Clearance On All Sides - Noise Level 3 Ft In Front Of Instrument Should Be <68 Dba - Dimensions: Width Is 50 Cm Or Less, Depth Is 75 Cm Or Less, Height When Door Is Closed Should Be 40 Cm Or Less, Height When Door Open Should Be 82 Cm Or Less - Maximum Heat Dissipation Into Room Under Steady-state Conditions Should Be 3311 Btu/h (0.97 Kw) Or Less - Electrical Requirements: 220-240 Vac, 6.2 A, 50-60 Hz - Class I Electrical Supply Inclusions: - Compatible Avr - Fixed Angle Aluminum Rotor For 50 Ml Tubes - Fixed-angle Conical Tube Aluminum Rotor For 15 Ml Tubes - Biocontainment Aluminum Rotor For 2.0 Ml Tubes - Swinging Bucket Aluminum Rotor For Microplates And Deep Well Microplates Terms And Conditions: 1. Supplier Shall Indicate Brand, Model, And Country Of Origin. 2. The Supplier Will Provide A Notarized Certificate Indicating That The Product Is Brand New, Not Reconditioned/refurbished Including Parts And Accessories. 3. Comes With Free Delivery And Installation To The Institute Of Pharmaceutical Sciences, National Institutes Of Health, Up Manila Which Should Be Done Within 60-90 Days Upon Acceptance Of Notice To Proceed. Note That Acknowledgment By The Supplier Through Email Constitutes The Date Of Acceptance. 4. The Supplier Will Witness And Help The Unpacking Of The Equipment To Ensure That All Items Are Included Inside And In Good Condition. 5. Free Relocation And Re-setup Of Equipment If Requested By The End-user Within The University Of The Philippines Manila Area Within The Warranty Period With Subsequent Installation Qualification And Operational Qualification With Documentation And Report. 6. Qualified Service Engineer/s Must Perform Equipment Start-up, Testing, Operation, And/or Installation With Proper Documentation And Report. 7. The Equipment Must Be Delivered And Ready To Use. Cables, Connectors, Adapters, And Accessories Even Not Specified But Are Essential For The Unit To Function Must Be Provided Free By The Winning Bidder. 8. Certification From The Manufacturer/local Distributor That In The Event Of A Change Of Local Distributor, Preventive Maintenance, Warranty, And Services Agreed Here Upon Will Be Honored By The Principal Manufacturer. 9. Certification Or Guarantee Letter From The Manufacturer/local Distributor To Ensure The Availability Of Parts, Supplies, And Accessories Will Not Be Discontinued For The Next 10 Years. 10. Undertaking To Provide Product Orientation And Operations Training For End-users And Troubleshooting Training For Research Staff Within Seven Days After Completion Of Installation. 11. Provide Bi-annual Preventive Maintenance And Calibration From The Distributor’s Qualified Engineer During The Warranty Period. 12. At Least A 2-year Warranty On Parts And Services. The Warranty Period Shall Commence From The Date Of Acceptance By The End-user, Testing, And Commissioning. 13. The Bidder Must Submit Certification That They Have The Capability For Corrective And Preventive Maintenance Of The Unit. 14. Availability Of Trained Service Engineers With Guaranteed Uptime Within 48 Hrs For Troubleshooting And Repair Of Unit Even After The Warranty Period. 15. Provide Operator’s And Service Manual (in English) Upon Delivery. 16. Price Should Be Inclusive Of All Applicable Taxes. Emergency Response Kit General Specifications: - Contains A Portable Spill Kit And First Aid Kit - The Portable Spill Kit Should Include The Following Items Packed In A Reusable Bag With Shoulder Strap - 32 Pcs Of 15 In. X 17-19 In. General Purpose Pads - 5 Pcs Of 3 In. X 4 Ft. Universal Socs - 1 Pc Of 18 In. X 18 In. Universal Absorbent Pillows - 1 Pair Of Nitrile Gloves - 2 Disposable Bags - 1 Pc Of Goggles - 1 Instruction Sheet - The First Aid Kit Should Include The Following Items Packed In A Bag With Handle - Gauze Pad 3x3 Inches (at Least 2pcs) - Gauze Pad 4x4 Inches (at Least 2pcs) - Gauze Bandage 3x10 Inches - Elastic Bandage - Triangular Cotton Bandage - Facemask - Aluminum Whistle - Alcohol At Least 60 Ml - Adhesive Bandage Strip (at Least 10pcs) - Povidone Iodine Pads (at Least 4pcs) - Alcohol Applicator Pad (at Least 10pcs) - Povidone Applicator Stick (at Least 5pcs) - Rubber Tourniquet - Cpr Barrier - Thermal Blanket - Surgical Tape - Burn Ointment - Instant Ice Pack - Tweezers - At Least 10 Pcs Of Safety Pins - Pocket Flashlight - Scissors Terms And Conditions: 1. Supplier Shall Indicate Brand, Model, And Country Of Origin. 2. Supplier Will Provide A Notarized Certificate Indicating That The Items Included Are Brand New And Not Reconditioned/refurbished. 3. Comes With Free Delivery To The Institute Of Pharmaceutical Sciences, National Institutes Of Health, Up Manila Which Should Be Done Within 60-90 Days Upon Acceptance Of The Notice To Proceed. Note That Acknowledgment By The Supplier Through Email Constitutes The Date Of Acceptance. 4. The Supplier Will Help Unpack The Bags To Ensure That All Items Are Included Inside And Are In Good Condition. 5. Price Should Be Inclusive Of All Applicable Taxes. Laboratory Water Bath General Specifications: - Dimensions (w X L X H) Are 68-72 X 33-37 X 24-28 Cm - Filling Volume Is Maximum Of 20l - Usable Immersion Depth Is Maximum Of 18 Cm - Bath Tank Is Made Of Stainless Steel - Usable Bath Opening Is At Least (w X L / D) Is 50 X 30 / 18 Cm Features: - Has Shaking Feature - Shaking Frequency (linear) Is 20 To 200 Rpm - Shaking Stroke Is At 15 Mm - Has Temperature Control - Uses Pid1 Microprocessor Temperature Control - Temperature Display Is Led - Has Keypad For Temperature Setting - Working Temperature Range Is At 20 To 100 °c - Temperature Stability Is At ±0.2 °c - Ambient Temperature Ranges From 5 To 40 °c - Splash-proof Design - Warning And Cut-off Protection For High/low Temperature - Comes With Bath Drains At The Bottom Portion Of The Unit - Electronic Timer For Setting The Running Time From 0:01 To 9:59 (h:min) - Has Removable Shaking Carriage - Provides Dry-running Protection With Audible And Optical Alarm - Has Removable Platform For Full Immersion Of The Sample Containers - Has Atc3 (absolute Temperature Calibration) 1-point-calibration - Has High-temperature Stability Inclusions: - Lift-up Cover - Basic Tray For Assembling Erlenmeyer Flasks From 25 To 1000 Ml Including Spring Clamps - Compatible Test Glass Insert 16/17 Mm Ø For 50 Test Tubes - Compatible Test Glass Insert 30 Mm Ø For 21 Test Tubes Terms And Conditions: 1. Supplier Shall Indicate Brand, Model, And Country Of Origin. 2. The Supplier Will Provide A Notarized Certificate Indicating That The Product Is Brand New, Not Reconditioned/refurbished Including Parts And Accessories. 3. Comes With Free Delivery And Setup To The Institute Of Pharmaceutical Sciences, National Institutes Of Health, Up Manila Which Should Be Done Within 60-90 Days Upon Acceptance Of Notice To Proceed. Note That Acknowledgment By The Supplier Through Email Constitutes The Date Of Acceptance. 4. The Supplier Will Witness And Help The Unpacking Of The Equipment To Ensure That All Items Are Included Inside And In Good Condition. 5. Free Relocation And Re-setup Of Equipment If Requested By The End-user Within The University Of The Philippines Manila Area Within The Warranty Period With Subsequent Installation Qualification And Operational Qualification With Documentation And Report. 6. Qualified Service Engineer/s Must Perform Equipment Start-up, Testing, Operation, And/or Installation With Proper Documentation And Report. 7. The Equipment Must Be Delivered And Ready To Use. Cables, Connectors, Adapters, And Accessories Even Not Specified But Are Essential For The Unit To Function Must Be Provided Free By The Winning Bidder. 8. Certification From The Manufacturer/local Distributor That In The Event Of A Change Of Local Distributor, Preventive Maintenance, Warranty, And Services Agreed Here Upon Will Be Honored By The Principal Manufacturer. 9. Certification Or Guarantee Letter From The Manufacturer/local Distributor To Ensure The Availability Of Parts, Supplies, And Accessories Will Not Be Discontinued For The Next 10 Years. 10. Undertaking To Provide Product Orientation And Operations Training For End-users And Troubleshooting Training For Research Staff Within Seven Days After Completion Of Installation. 11. Provide Bi-annual Preventive Maintenance And Calibration From The Distributor’s Qualified Engineer During The Warranty Period. 12. At Least A 2-year Warranty On Parts And Services. The Warranty Period Shall Commence From The Date Of Acceptance By The End-user, Testing, And Commissioning. 13. The Bidder Must Submit Certification That They Have The Capability For Corrective And Preventive Maintenance Of The Unit. 14. Availability Of Trained Service Engineers With Guaranteed Uptime Within 48 Hrs For Troubleshooting And Repair Of Unit Even After The Warranty Period. 15. Provide Operator’s And Service Manual (in English) Upon Delivery. 16. Price Should Be Inclusive Of All Applicable Taxes. Vortex Mixer And Accessories General Specifications: - Mixing Frequency Ranges From 300-3000 Rpm - Dimensions (w X D X H) Should Be Less Than 22 X 32 X 15 Cm - Weighs Less Than 7 Kg - Ø Of Mixing Orbit Is 3 Mm - Has A Timer That Ranges From 15 Sec To 99:30 Hours And Capable Of Continuous Mode - Has Mix Control, Anti-spill Technology, Short/interval Mix, Time/temp Mode, And Pause Function - Can Accommodate Various Sample Vessels And Plate Formats From 5 Μl To 50 Ml - Temperature Ranges From 15 °c Below Rt Up To 100 °c - Capable Of Heating, Mixing, And Cooling Accessories Included: - Compatible Holder For Microtiter Plates And Deep Well Plates With Suitable Lid/cover - Compatible Holder For 1.5 Ml Microtubes - Compatible Holder For 15 Ml Conical Tubes Terms And Conditions: 1. Supplier Shall Indicate Brand, Model, And Country Of Origin. 2. The Supplier Will Provide A Notarized Certificate Indicating That The Product Is Brand New, Not Reconditioned/refurbished Including Parts And Accessories. 3. Comes With Free Delivery And Setup To The Institute Of Pharmaceutical Sciences, National Institutes Of Health, Up Manila Which Should Be Done Within 60-90 Days Upon Acceptance Of Notice To Proceed. Note That Acknowledgment By The Supplier Through Email Constitutes The Date Of Acceptance. 4. The Supplier Will Witness And Help The Unpacking Of The Equipment To Ensure That All Items Are Included Inside And In Good Condition. 5. Free Relocation And Re-setup Of Equipment If Requested By The End-user Within The University Of The Philippines Manila Area Within The Warranty Period With Subsequent Installation Qualification And Operational Qualification With Documentation And Report. 6. Qualified Service Engineer/s Must Perform Equipment Start-up, Testing, Operation, And/or Installation With Proper Documentation And Report. 7. The Equipment Must Be Delivered And Ready To Use. Cables, Connectors, Adapters, And Accessories Even Not Specified But Are Essential For The Unit To Function Must Be Provided Free By The Winning Bidder. 8. Certification From The Manufacturer/local Distributor That In The Event Of A Change Of Local Distributor, Preventive Maintenance, Warranty, And Services Agreed Here Upon Will Be Honored By The Principal Manufacturer. 9. Certification Or Guarantee Letter From The Manufacturer/local Distributor To Ensure The Availability Of Parts, Supplies, And Accessories Will Not Be Discontinued For The Next 10 Years. 10. Undertaking To Provide Product Orientation And Operations Training For End-users And Troubleshooting Training For Research Staff Within Seven Days After Completion Of Installation. 11. Provide Bi-annual Preventive Maintenance And Calibration From The Distributor’s Qualified Engineer During The Warranty Period. 12. At Least A 2-year Warranty On Parts And Services. The Warranty Period Shall Commence From The Date Of Acceptance By The End-user, Testing, And Commissioning. 13. The Bidder Must Submit Certification That They Have The Capability For Corrective And Preventive Maintenance Of The Unit. 14. Availability Of Trained Service Engineers With Guaranteed Uptime Within 48 Hrs For Troubleshooting And Repair Of Unit Even After The Warranty Period. 15. Provide Operator’s And Service Manual (in English) Upon Delivery. 16. Price Should Be Inclusive Of All Applicable Taxes. Ultrasonic Waterbath General Specifications: - Tank Capacity Is 9.5 L With The Following Dimensions (l X W X D) 11-13 X 9-11 X 5-7 Inches - Overall Size Of The Equipment Should Be Around (l X W X D) 15-17 X 15-17 X 14-16 Inches - Frequency Should Be At 40 Khz - Needs To Have A Drain - Comes With A Cover - Has 40 Khz Rugged Industrial Transducers With Sweep Frequency - With Heater That Heat Up To 69°c - Has A Dual Power And Power Tracking - Has A Sleep Mode - Capable Of Degas Wave Modulation And Auto Ultrasonics Activation - Has High Temperature Alarm - Front Panel Auto Temp Calibration - Body Is Made Of Chemical-resistant Plastic Inclusions: - Compatible Perforated Tray - Compatible Mesh Basket - Compatible Beaker Positioning Cover - Compatible Solid Insert Tray - Compatible Support Rack Terms And Conditions: 1. Supplier Shall Indicate Brand, Model, And Country Of Origin. 2. Supplier Will Provide A Notarized Certificate Indicating That The Product Is Brand New, Not Reconditioned/refurbished Including Parts And Accessories. 3. Comes With Free Delivery And Setup To The Institute Of Pharmaceutical Sciences, National Institutes Of Health, Up Manila Which Should Be Done Within 60-90 Days Upon Acceptance Of Notice To Proceed. Note That Acknowledgment By The Supplier Through Email Constitutes The Date Of Acceptance. 4. The Supplier Will Witness And Help The Unpacking Of The Equipment To Ensure That All Items Are Included Inside And In Good Condition. 5. Free Relocation And Re-setup Of Equipment If Requested By The End-user Within The University Of The Philippines Manila Area Within The Warranty Period With Subsequent Installation Qualification And Operational Qualification With Documentation And Report. 6. Qualified Service Engineer/s Must Perform Equipment Start-up, Testing, Operation, And/or Installation With Proper Documentation And Report. 7. The Equipment Must Be Delivered Ready To Use. Cables, Connectors, Adapters, And Accessories Even Not Specified But Are Essential For The Unit To Function Must Be Provided Free By The Winning Bidder. 8. Certification From The Manufacturer/local Distributor That In The Event Of A Change Of Local Distributor, Preventive Maintenance, Warranty, And Services Agreed Here Upon Will Be Honored By The Principal Manufacturer. 9. Certification Or Guarantee Letter From The Manufacturer/local Distributor To Ensure The Availability Of Parts, Supplies, And Accessories And Will Not Be Discontinued For The Next 10 Years. 10. Undertaking To Provide Product Orientation And Operations Training For End-user And Troubleshooting Training For Research Staff Within Seven Days After Completion Of Installation. 11. Provide A Bi-annual Preventive Maintenance And Calibration From The Distributor’s Qualified Engineer During The Warranty Period. 12. At Least 2-year Warranty On Parts And Services. The Warranty Period Shall Commence From The Date Of Acceptance By The End-user, Testing, And Commissioning. 13. The Bidder Must Submit Certification That They Have The Capability For Corrective And Preventive Maintenance Of The Unit. 14. Availability Of Trained Service Engineers With Guaranteed Uptime Within 48 Hrs For Troubleshooting And Repair Of Unit Even After The Warranty Period. 15. Provide Operator’s And Service Manual (in English) Upon Delivery. 16. Price Should Be Inclusive Of All Applicable Taxes. Laboratory Refrigerator General Specifications: - External Dimensions Measure 708-802 X 463-467 X 1088-1092 Mm (w X D X H) - Internal Dimensions Measure 718-722 X 298-302 X 723-727 Mm (w X D X H) - Volume Capacity Is 150 Liters Or More - External Cabinet Is Made With Galvanised Steel With Baked-on Finish - Internal Cabinet Is Made With Stainless Steel - Has Sliding Glass Doors Made With Double-glazing Glass And Heat-reflective Film - The Shelves Are Made Of Hard Steel Wire - Insulation Material Is Polyurethane Foam - Has Hfc Refrigerant - Has Led/2 Casters For Lighting - Mechanical Components Are As Follows: - Access Port: Ø30 Mm On Back Wall - Compressor: Hermetic Type, 90w - Evaporator: Fin & Tube, Forced-air Circulation - Condenser: Wire & Tube - Defrosting: Cyclical Defrosting And Evaporator Temp. Detection System - Defrosting Heaters: 87w - Temperature Control Ranges From 2 To 14 °c - Temperature Is Displayed Digitally With 1°c Increments When Adjusted - Unit Should Have An Alarm System To Indicate Changes In The Set Temperature Value - Unit Should Have Buzzer And/or Door Ajar Lamp - Rohs Compliant Inclusions: - With Compatible Avr Terms And Conditions: 1. Supplier Shall Indicate Brand, Model, And Country Of Origin. 2. The Supplier Will Provide A Notarized Certificate Indicating That The Product Is Brand New, Not Reconditioned/refurbished Including Parts And Accessories. 3. Comes With Free Delivery And Installation To The Institute Of Pharmaceutical Sciences, National Institutes Of Health, Up Manila Which Should Be Done Within 90-120 Days Upon Acceptance Of Notice To Proceed. Note That Acknowledgment By The Supplier Through Email Constitutes The Date Of Acceptance. 4. The Supplier Will Witness And/or Help The Unpacking Of The Equipment To Ensure That All Items Are Included Inside And In Good Condition. 5. Free Relocation And Re-setup Of Equipment If Requested By The End-user Within The University Of The Philippines Manila Area Within The Warranty Period With Subsequent Installation Qualification And Operational Qualification With Documentation And Report. 6. Qualified Service Engineer/s Must Perform Installation Qualification And Operational Qualification With Documentation And Report. 7. The Equipment Must Be Delivered Ready To Use. Cables, Connectors, Adapters, And Accessories Even Not Specified But Are Essential For The Unit To Function Must Be Provided Free By The Winning Bidder. 8. Certification From The Manufacturer/local Distributor That In The Event Of A Change Of Local Distributor, Preventive Maintenance, Warranty, And Services Agreed Here Upon Will Be Honored By The Principal Manufacturer. 9. Certification Or Guarantee Letter From The Manufacturer/local Distributor To Ensure The Availability Of Parts, Supplies, And Accessories And Will Not Be Discontinued For The Next 10 Years. 10. Undertaking To Provide Product Orientation And Operations Training For End-user And Troubleshooting Training For Research Staff Within Seven Days After Completion Of Installation. 11. Provide A Bi-annual Preventive Maintenance And Calibration From The Distributor’s Qualified Engineer During The Warranty Period. 12. At Least 2-year Warranty On Parts And Services. Warranty Period Shall Commence From The Date Of Acceptance By The End-user, Testing, And Commissioning. 13. The Bidder Must Submit Certification That They Have The Capability For Corrective And Preventive Maintenance Of The Unit. 14. Availability Of Trained Service Engineers With Guaranteed Uptime Within 48 Hrs For Troubleshooting And Repair Of Unit Even After The Warranty Period. 15. Provide Operator’s And Service Manual (in English) Upon Delivery. 16. Price Should Be Inclusive Of All Applicable Taxes. Water Filtration System With Vacuum Pump General Specifications: - All-in-one Filtration System - Has Vacuum Source With Filtration Apparatus - Oil-free - With Vacuum Regulator And Thermal Protection - Chemical Resistant - Has Maximum Vacuum Of 99 Mbar Abs. - Has Maximum Flow Rate Of 20l/min - Noise Level Is At 50 Db - Hose Barb Size Is Id8 (5/16 Inch) - Dimensions (l X W X H): 32-36 X 22-26 X 28-32 Cm - Electrical Data Are As Follows: - Max Power: 60w - Max Current: 0.3a - Comes With 2 Sets Of Glass Filtration Apparatus With The Following Specifications: - Funnel And Support Base Is Made Of Borosilicate Glass - Funnel Capacity Is 300 Ml - Membrane Support Is Made Of Sintered Glass - Clamp Is Made Of Aluminum - The Included Rubber Stopper Is Made Of Silicone Rubber (no. 8) - Filtration Adaptor Is Made Of Pp Material - The Filter Diameter Is 47 Mm - The Storage Bottle Should Be Made Of Borosilicate Glass And Has 1000 Ml Storage Capacity With Id8 Hose Barb Inclusions: - Comes With 1 Pack Of 47 Mm Membrane Filter Terms And Conditions: 1. Supplier Shall Indicate Brand, Model, And Country Of Origin. 2. The Supplier Will Provide A Notarized Certificate Indicating That The Product Is Brand New, Not Reconditioned/refurbished Including Parts And Accessories. 3. Comes With Free Delivery And Setup To The Institute Of Pharmaceutical Sciences, National Institutes Of Health, Up Manila Which Should Be Done Within 60-90 Days Upon Acceptance Of Notice To Proceed. Note That Acknowledgment By The Supplier Through Email Constitutes The Date Of Acceptance. 4. The Supplier Will Witness And Help The Unpacking Of The Equipment To Ensure That All Items Are Included Inside And In Good Condition. 5. Free Relocation And Re-setup Of Equipment If Requested By The End-user Within The University Of The Philippines Manila Area Within The Warranty Period With Subsequent Installation Qualification And Operational Qualification With Documentation And Report. 6. Qualified Service Engineer/s Must Perform Equipment Start-up, Testing, Operation, And/or Installation With Proper Documentation And Report. 7. The Equipment Must Be Delivered Ready To Use. Cables, Connectors, Adapters, And Accessories Even Not Specified But Are Essential For The Unit To Function Must Be Provided Free By The Winning Bidder. 8. Certification From The Manufacturer/local Distributor That In The Event Of A Change Of Local Distributor, Preventive Maintenance, Warranty, And Services Agreed Here Upon Will Be Honored By The Principal Manufacturer. 9. Certification Or Guarantee Letter From The Manufacturer/local Distributor To Ensure The Availability Of Parts, Supplies, And Accessories And Will Not Be Discontinued For The Next 10 Years. 10. Undertaking To Provide Product Orientation And Operations Training For End-user And Troubleshooting Training For Research Staff Within Seven Days After Completion Of Delivery And/or Installation. 11. Provide A Bi-annual Preventive Maintenance And Calibration From The Distributor’s Qualified Engineer During The Warranty Period. 12. At Least 2-year Warranty On Parts And Services. The Warranty Period Shall Commence From The Date Of Acceptance By The End-user, Testing, And Commissioning. 13. The Bidder Must Submit Certification That They Have The Capability For Corrective And Preventive Maintenance Of The Unit. 14. Availability Of Trained Service Engineers With Guaranteed Uptime Within 48 Hrs For Troubleshooting And Repair Of Unit Even After The Warranty Period. 15. Provide Operator’s And Service Manual (in English) Upon Delivery. 16. Price Should Be Inclusive Of All Applicable Taxes. Automated Solid Phase Extraction Manifold General Specifications: - Gas Regulator And Gas Gauge Range: - Output: 0-30 Psi - Input: 100 Psi Maximum - Dimensions (hxwxd): 20-23 X 22-25 X 25-27 In - Sample Rack Dimensions (hxwxd): 6-8 X 16-18 X 10-13 In - With Operating System Software With 24 Default Methods Stored In The Software - Liquid Management - Air Syringe: One 10 Ml Air Syringe - Lh Syringe: One 10 Ml Liquid Handling Syringe - 12-port Rotary Valve With Sliding Seal - Stainless Steel Nozzle - With 6 Or More Sample Inlet And Are Made Of Tfe Tubing, 1/16” Id - Sample Pumps - Has Positive Displacement - Accuracy Is At +/- 2.5% - Ceramic Piston And Liner - Non Use Of Acetic Acid, Acetone - Has Various Spe Configurations - 1 Ml Syringe: Compatible Cartridges - 3 Ml Syringe: Compatible Cartridges - 6 Ml Syringe: Compatible Cartridges - Disk Version: 47 Mm Spe Disk Features: - Automates Sample Loading Of Liquids Onto Spe Cartridges - Automates Eluting Of Spe Cartridges With Organic Solvent - Has Closed Systems With Fan To Vent Solvent Vapors - Spe Technology For Liquid-liquid Extraction - Uses Positive Pressure Loading And Elution Of Samples And Solvents Terms And Conditions: 1. Supplier Shall Indicate Brand, Model, And Country Of Origin. 2. Supplier Will Provide A Notarized Certificate Indicating That The Product Is Brand New, Not Reconditioned/refurbished Including Parts And Accessories. 3. Comes With Free Delivery And Setup To The Institute Of Pharmaceutical Sciences, National Institutes Of Health, Up Manila Which Should Be Done Within 60-90 Days Upon Acceptance Of Notice To Proceed. Note That Acknowledgment By The Supplier Through Email Constitutes The Date Of Acceptance. 4. The Supplier Will Witness And/or Help The Unpacking Of The Equipment To Ensure That All Items Are Included Inside And In Good Condition. 5. Free Relocation And Re-setup Of Equipment If Requested By The End-user Within The University Of The Philippines Manila Area Within The Warranty Period With Subsequent Installation Qualification And Operational Qualification With Documentation And Report. 6. Qualified Service Engineer/s Must Perform Equipment Start-up, Testing, Operation, And/or Installation With Proper Documentation And Report. 7. The Equipment Must Be Delivered Ready To Use. Cables, Connectors, Adapters, And Accessories Even Not Specified But Are Essential For The Unit To Function Must Be Provided Free By The Winning Bidder. 8. Certification From The Manufacturer/local Distributor That In The Event Of A Change Of Local Distributor, Preventive Maintenance, Warranty, And Services Agreedsupply Of Various Laboratory Equipment For The Project, Project 2: Establishment Of Pharmaceutical Sciences Services For Clinical Research Chemical Storage Cabinet General Specifications: - Internal Volume: 440 To 450 L - Dimensions Interior (w X D X H): 20-22 X 17-19 X 66-68 Inches - Dimensions Exterior (w X D X H): 24-26 X 20-22 X 73-75 Inches - Can Put 3 To 6 Shelves Inside - Can Put 4 To 7 Trays Inside - Maximum Load Per Shelf Is 50 Kg Or More - Made With Corrosion-resistant Interior Material - With Built-in Ventilation Hole - Compatible With Extraction Module As Filter Inclusions: - 3 Shelves - 4 Corrosion-resistant Pp Trays - 1 Extraction Module Terms And Conditions: 1. Supplier Shall Indicate Brand, Model, And Country Of Origin. 2. The Supplier Will Provide A Notarized Certificate Indicating That The Product Is Brand New, Not Reconditioned/refurbished Including Parts And Accessories. 3. Comes With Free Delivery To The Institute Of Pharmaceutical Sciences, National Institutes Of Health, Up Manila And Setup, Which Should Be Done Within 90-120 Days Upon Acceptance Of Notice To Proceed. Note That Acknowledgment By The Supplier Through Email Constitutes The Date Of Acceptance. 4. The Supplier Will Witness And Help The Unpacking Of The Equipment To Ensure That All Items Are Included Inside And In Good Condition. 5. Free Relocation And Re-setup Of Equipment If Requested By The End-user Within The University Of The Philippines Manila Area Within The Warranty Period With Subsequent Installation Qualification And Operational Qualification With Documentation And Report. 6. Qualified Service Engineer/s Must Perform Operational Qualification With Documentation And Report. 7. The Equipment Must Be Delivered And Ready To Use. Cables, Connectors, Adapters, And Accessories Even Not Specified But Are Essential For The Unit To Function Must Be Provided Free By The Winning Bidder. 8. Certification From The Manufacturer/local Distributor That In The Event Of A Change Of Local Distributor, Preventive Maintenance, Warranty, And Services Agreed Here Upon Will Be Honored By The Principal Manufacturer. 9. Certification Or Guarantee Letter From The Manufacturer/local Distributor To Ensure The Availability Of Parts, Supplies, And Accessories Will Not Be Discontinued For The Next 10 Years. 10. Undertaking To Provide Product Orientation And Operations Training For End-users And Troubleshooting Training For Research Staff Within Seven Days After Completion Of Installation. 11. Provide Bi-annual Preventive Maintenance And Calibration From The Distributor’s Qualified Engineer During The Warranty Period. 12. At Least A 2-year Warranty On Parts And Services. The Warranty Period Shall Commence From The Date Of Acceptance By The End-user, Testing, And Commissioning. 13. The Bidder Must Submit Certification That They Have The Capability For Corrective And Preventive Maintenance Of The Unit. 14. Availability Of Trained Service Engineers With Guaranteed Uptime Within 48 Hrs For Troubleshooting And Repair Of Unit Even After The Warranty Period. 15. Provide Operator’s And Service Manual (in English) Upon Delivery. 16. Price Should Be Inclusive Of All Applicable Taxes. Safety Cabinet For Corrosives General Specifications: - External Dimensions (w X D X H): 680-687 Mm X 700-705 X 2045-2055 Mm - Can Put 4 Trays Per Section - Tray Capacity Per Volume Of Bottle: - Each Tray Can Fit 9 Bottles With 2.5-4l Volume Capacity - Each Tray Can Fit 12 Bottles With 2.0l Volume Capacity - Main Body Is Made Of Industrial-grade Electro-galvanized Steel - Trays Are Made Of Polypropylene Material - Door Should Be Made With Powder-coated Electro-galvanized Steel With 6 Mm Thick Acrylic Window And A Lockable Swing Handle - With Voc Sensor And Alarm - Power Requirements: 220-240 Vac, 50-60 Hz, 1 Phase Power Supply - Uses A Microprocessor-based Control System - With Airflow Monitoring Via An Easy-to-read Lcd Panel Inclusion: - 1 Compatible Avr Per Unit - 1 Activated Carbon Filter Per Unit Features: - Has Dual Filtration System (main Filter Uses Activated Carbon Filter And Secondary Filter Is Hepa Filter) - With Antimicrobial Powder Coating - With Door Safety Lock Terms And Conditions: 1. Supplier Shall Indicate Brand, Model, And Country Of Origin. 2. The Supplier Will Provide A Notarized Certificate Indicating That The Product Is Brand New, Not Reconditioned/refurbished Including Parts And Accessories. 3. Comes With Free Delivery To The Institute Of Pharmaceutical Sciences, National Institutes Of Health, Up Manila And Setup, Which Should Be Done Within 90-120 Days Upon Acceptance Of Notice To Proceed. Note That Acknowledgment By The Supplier Through Email Constitutes The Date Of Acceptance. 4. The Supplier Will Witness And Help The Unpacking Of The Equipment To Ensure That All Items Are Included Inside And In Good Condition. 5. Free Relocation And Re-setup Of Equipment If Requested By The End-user Within The University Of The Philippines Manila Area Within The Warranty Period With Subsequent Installation Qualification And Operational Qualification With Documentation And Report. 6. Qualified Service Engineer/s Must Perform Operational Qualification With Documentation And Report. 7. The Equipment Must Be Delivered And Ready To Use. Cables, Connectors, Adapters, And Accessories Even Not Specified But Are Essential For The Unit To Function Must Be Provided Free By The Winning Bidder. 8. Certification From The Manufacturer/local Distributor That In The Event Of A Change Of Local Distributor, Preventive Maintenance, Warranty, And Services Agreed Here Upon Will Be Honored By The Principal Manufacturer. 9. Certification Or Guarantee Letter From The Manufacturer/local Distributor To Ensure The Availability Of Parts, Supplies, And Accessories Will Not Be Discontinued For The Next 10 Years. 10. Undertaking To Provide Product Orientation And Operations Training For End-users And Troubleshooting Training For Research Staff Within Seven Days After Completion Of Installation. Multi-position Hotplate Stirrer General Specifications: - 6 Position Hotplate Stirrer - Independent Heat And Stirring Control For Each Plate - Heat Up To 380°c - Electronically Controlled Stirring From 60 To 150 Rpm - Durable Bearing Type Motor - Ceramic Coated Stainless Steel Top Plate - Each Plate Dimension Is 180 Mm X 180 Mm - Has Anti-corrosive Powder-coated Steel Body - Uses An Electronic Solid-state Controller - Temperature Range: Ambient +5°c To 380°c - Motor Is Heavy Duty Bearing Operated Shaft - Electric Supply: 220v 50/60 Hz Inclusions: - Cylindrical Magnetic Stirring Bars Of Different Sizes: - 6 Pieces; Size Of Approximately 0.31 In. Diameter And 2 In. Length - 6 Pieces; Size Of Approximately 0.125 In. Diameter And 0.5 In. Length - 6 Pieces; Size Of Approximately 0.31 In. Diameter And 1.61 In. Length - 6 Pieces; Size Of Approximately 0.31 In. Diameter And 1 In. Length Terms And Conditions: 1. Supplier Shall Indicate Brand, Model, And Country Of Origin. 2. The Supplier Will Provide A Notarized Certificate Indicating That The Product Is Brand New, Not Reconditioned/refurbished Including Parts And Accessories. 3. Comes With Free Delivery To The Institute Of Pharmaceutical Sciences, National Institutes Of Health, Up Manila And Setup, Which Should Be Done Within 60-90 Days Upon Acceptance Of Notice To Proceed. Note That Acknowledgment By The Supplier Through Email Constitutes The Date Of Acceptance. 4. The Supplier Will Witness And Help The Unpacking Of The Equipment To Ensure That All Items Are Included Inside And In Good Condition. 5. Free Relocation And Re-setup Of Equipment If Requested By The End-user Within The University Of The Philippines Manila Area Within The Warranty Period With Subsequent Installation Qualification And Operational Qualification With Documentation And Report. 6. Qualified Service Engineer/s Must Perform Equipment Start-up, Testing, Operation, And/or Installation With Proper Documentation And Report. 7. The Equipment Must Be Delivered And Ready To Use. Cables, Connectors, Adapters, And Accessories Even Not Specified But Are Essential For The Unit To Function Must Be Provided Free By The Winning Bidder. 8. Certification From The Manufacturer/local Distributor That In The Event Of A Change Of Local Distributor, Preventive Maintenance, Warranty, And Services Agreed Here Upon Will Be Honored By The Principal Manufacturer. 9. Certification Or Guarantee Letter From The Manufacturer/local Distributor To Ensure The Availability Of Parts, Supplies, And Accessories Will Not Be Discontinued For The Next 10 Years. 10. Undertaking To Provide Product Orientation And Operations Training For End-users And Troubleshooting Training For Research Staff Within Seven Days After Completion Of Installation. 11. Provide Bi-annual Preventive Maintenance And Calibration From The Distributor’s Qualified Engineer During The Warranty Period. 12. At Least A 2-year Warranty On Parts And Services. The Warranty Period Shall Commence From The Date Of Acceptance By The End-user, Testing, And Commissioning. 13. The Bidder Must Submit Certification That They Have The Capability For Corrective And Preventive Maintenance Of The Unit. 14. Availability Of Trained Service Engineers With Guaranteed Uptime Within 48 Hrs For Troubleshooting And Repair Of Unit Even After The Warranty Period. 15. Provide Operator’s And Service Manual (in English) Upon Delivery. Price Should Be Inclusive Of All Applicable Taxes 11. Provide Bi-annual Preventive Maintenance And Calibration From The Distributor’s Qualified Engineer During The Warranty Period. 12. At Least A 2-year Warranty On Parts And Services. The Warranty Period Shall Commence From The Date Of Acceptance By The End-user, Testing, And Commissioning. 13. The Bidder Must Submit Certification That They Have The Capability For Corrective And Preventive Maintenance Of The Unit. 14. Availability Of Trained Service Engineers With Guaranteed Uptime Within 48 Hrs For Troubleshooting And Repair Of Unit Even After The Warranty Period. 15. Provide Operator’s And Service Manual (in English) Upon Delivery. 16. Price Should Be Inclusive Of All Applicable Taxes. Ultralow Freezer General Specifications: - External Dimensions (w X D X H): 665-675 X 878-885 X 1835-1845 Mm - Internal Dimensions (w X D X H): 485-495 X 595-605 X 1225-1235 Mm - With Total Capacity Of 360 Liters Or More - Temperature Control Range Is From -50 To -86°c In 1° Increments - Has A Microprocessor Controller With Non-volatile Memory - Has Lcd Touch Screen Display - Uses Pt-1000 As Temperature Sensor - Has Independent Dual-cooling Refrigeration System With 2 Compressors At 1100 W - Uses Hfc Mixed Refrigerant - Uses Puf/vip Plus As Insulation Material With 80 Mm Thickness - Has 1 Outer Door With Lock - Has 2 Inner Doors - Has 3 Stainless Steel Shelves Inside With A Maximum Load Of 50 Kg - With 2 Vacuum Release Ports (1 Automatic, 1 Manual) - With 3 Access Ports: 1 At The Back And 2 At The Bottom - Has 4 Casters (with 2 Leveling Feet) - Has Visual, Buzzer, And Remote Alarm For Power Failure, High Temperature, And Low Temperature - Has Visual And Buzzer Alarm If Door Left Open - Filterless Design - Power Supply: 230v - Noise Level: 50 Dba Inclusions: - Compatible Avr - Compatible Liquid Co2 Back-up (with Filled Tank) - Cryosafety Gloves - Ice Scraper Terms And Conditions: 1. Supplier Shall Indicate Brand, Model, And Country Of Origin. 2. The Supplier Will Provide A Notarized Certificate Indicating That The Product Is Brand New, Not Reconditioned/refurbished Including Parts And Accessories. 3. Comes With Free Delivery And Installation, Which Should Be Done Within 90-120 Days Upon Acceptance Of Notice To Proceed. Note That Acknowledgment By The Supplier Through Email Constitutes The Date Of Acceptance. 4. The Supplier Will Witness And Help The Unpacking Of The Equipment To Ensure That All Items Are Included Inside And In Good Condition. 5. Free Relocation And Re-setup Of Equipment If Requested By The End-user Within The University Of The Philippines Manila Area Within The Warranty Period With Subsequent Installation Qualification And Operational Qualification With Documentation And Report. 6. Qualified Service Engineer/s Must Perform Installation Qualification And Operational Qualification With Documentation And Report. 7. The Equipment Must Be Delivered And Ready To Use. Cables, Connectors, Adapters, And Accessories Even Not Specified But Are Essential For The Unit To Function Must Be Provided Free By The Winning Bidder. 8. Certification From The Manufacturer/local Distributor That In The Event Of A Change Of Local Distributor, Preventive Maintenance, Warranty, And Services Agreed Here Upon Will Be Honored By The Principal Manufacturer. 9. Certification Or Guarantee Letter From The Manufacturer/local Distributor To Ensure The Availability Of Parts, Supplies, And Accessories Will Not Be Discontinued For The Next 10 Years. 10. Undertaking To Provide Product Orientation And Operations Training For End-users And Troubleshooting Training For Research Staff Within Seven Days After Completion Of Installation. 11. Provide Bi-annual Preventive Maintenance And Calibration From The Distributor’s Qualified Engineer During The Warranty Period. 12. At Least A 2-year Warranty On Parts And Services. The Warranty Period Shall Commence From The Date Of Acceptance By The End-user, Testing, And Commissioning. 13. The Bidder Must Submit Certification That They Have The Capability For Corrective And Preventive Maintenance Of The Unit. 14. Availability Of Trained Service Engineers With Guaranteed Uptime Within 48 Hrs For Troubleshooting And Repair Of Unit Even After The Warranty Period. 15. Provide Operator’s And Service Manual (in English) Upon Delivery. 16. Price Should Be Inclusive Of All Applicable Taxes. Safety Shower And Eyewash General Specifications: - Eyewash Bowl And Shower Head Diameter: 255-265 Mm - Dimensions Of Assembled Station: 295-305 Mm X 845-855 Mm X 2375-2385 Mm - Pipe Wall Thickness: ~2.5 Mm - Work Pressure: 0.2~0.6 Mpa (2~6 Bar) - Eye Wash Flow: >11.4l/min (3 Us Gallon) - Shower Flow: >75.7l/min (20 Us Gallon) - Working Temperature Range From 5-35°c - Shower Should Be Operated Using A Pull Rod Lever - Eyewash Should Be Operated Using A Flag Handle Switch Valve And/or Foot Pedal Switch Valve - Floor Mounted Using Expansion Bolt - All Parts Should Be Made From High-quality 304 Stainless Steel (except For Eyewash That Can Include Abs Plastic) - With 12-month Rust-free Warranty - Should Be Ansi Z358.1-2014 (us Standard) Certified Terms And Conditions: 1. Supplier Shall Indicate Brand, Model, And Country Of Origin. 2. The Supplier Will Provide A Notarized Certificate Indicating That The Product Is Brand New, Not Reconditioned/refurbished Including Parts And Accessories. 3. Comes With Free Delivery And Installation To The Institute Of Pharmaceutical Sciences, National Institutes Of Health, Up Manila Which Should Be Done Within 90-120 Days Upon Acceptance Of Notice To Proceed. Note That Acknowledgment By The Supplier Through Email Constitutes The Date Of Acceptance. 4. The Supplier Will Witness And Help The Unpacking Of The Equipment To Ensure That All Items Are Included Inside And In Good Condition. 5. Free Relocation And Re-setup Of Equipment If Requested By The End-user Within The University Of The Philippines Manila Area Within The Warranty Period With Subsequent Installation Qualification And Operational Qualification With Documentation And Report. 6. Qualified Service Engineer/s Must Perform Installation Qualification And Operational Qualification With Documentation And Report. 7. The Equipment Must Be Delivered And Ready To Use. Accessories Not Specified But Are Essential For The Unit To Function Must Be Provided Free By The Winning Bidder. 8. Certification From The Manufacturer/local Distributor That In The Event Of A Change Of Local Distributor, Preventive Maintenance, Warranty, And Services Agreed Here Upon Will Be Honored By The Principal Manufacturer. 9. Certification Or Guarantee Letter From The Manufacturer/local Distributor To Ensure The Availability Of Parts, Supplies, And Accessories Will Not Be Discontinued For The Next 10 Years. 10. Undertaking To Provide Product Orientation And Operations Training For End-users And Troubleshooting Training For Research Staff Within Seven Days After Completion Of Installation. 11. Provide Bi-annual Preventive Maintenance And Calibration From The Distributor’s Qualified Engineer During The Warranty Period. 12. At Least A 2-year Warranty On Parts And Services. The Warranty Period Shall Commence From The Date Of Acceptance By The End-user, Testing, And Commissioning. 13. The Bidder Must Submit Certification That They Have The Capability For Corrective And Preventive Maintenance Of The Unit. 14. Availability Of Trained Service Engineers With Guaranteed Uptime Within 48 Hrs For Troubleshooting And Repair Of Unit Even After The Warranty Period. 15. Provide Operator’s And Service Manual (in English) Upon Delivery. 16. Price Should Be Inclusive Of All Applicable Taxes. Nitrogen Evaporation System General Specifications: - Ambient Temperature Range Is From +5°c To 120°c - Microprocessor Digital Pid For Temperature Control With Increments Of 0.1°c - Has Heating Temperature Method - With Touch Buttons And Led Display For Operating Panel - Manifold Size (w X D X H): 128-132 X 108-112 X 28-32 Mm - Flow Rate For Each Nozzle Control (20ea) - Has A Pinion Motion Stand - With Flow Control Valve To Serve As Connecting Port - Block Capacity: 2 Blocks (bl X 2ea) - Block Dimensions (w X D X H) Is 108-112 X88- 92 X 43-47 Mm - Overall Dimensions (w X D X H): 308-312 X248-252 X 433-437 Mm - Each Nozzle Exhaust System Should Be Contamination Free Inclusions: - 2 Blocks Of 1.5 Ml Microtube X 20 Holes With Ø11 Mm - 2 Blocks Of 10 Ml Tube X 20 Holes With Ø13 Mm - 2 Blocks Of 15 Ml Tube X 20 Holes With Ø16 Mm - 1 Filled Nitrogen Tank With Appropriate Connectors Terms And Conditions: 1. Supplier Shall Indicate Brand, Model, And Country Of Origin. 2. The Supplier Will Provide A Notarized Certificate Indicating That The Product Is Brand New, Not Reconditioned/refurbished Including Parts And Accessories. 3. Comes With Free Delivery And Setup To The Institute Of Pharmaceutical Sciences, National Institutes Of Health, Up Manila Which Should Be Done Within 60-90 Days Upon Acceptance Of Notice To Proceed. Note That Acknowledgment By The Supplier Through Email Constitutes The Date Of Acceptance. 4. The Supplier Will Witness And Help The Unpacking Of The Equipment To Ensure That All Items Are Included Inside And In Good Condition. 5. Free Relocation And Re-setup Of Equipment If Requested By The End-user Within The University Of The Philippines Manila Area Within The Warranty Period With Subsequent Installation Qualification And Operational Qualification With Documentation And Report. 6. Qualified Service Engineer/s Must Perform Equipment Start-up, Testing, Operation, And/or Installation With Proper Documentation And Report. 7. The Equipment Must Be Delivered And Ready To Use. Cables, Connectors, Adapters, And Accessories Even Not Specified But Are Essential For The Unit To Function Must Be Provided Free By The Winning Bidder. 8. Certification From The Manufacturer/local Distributor That In The Event Of A Change Of Local Distributor, Preventive Maintenance, Warranty, And Services Agreed Here Upon Will Be Honored By The Principal Manufacturer. 9. Certification Or Guarantee Letter From The Manufacturer/local Distributor To Ensure The Availability Of Parts, Supplies, And Accessories Will Not Be Discontinued For The Next 10 Years. 10. Undertaking To Provide Product Orientation And Operations Training For End-users And Troubleshooting Training For Research Staff Within Seven Days After Completion Of Installation. 11. Provide Bi-annual Preventive Maintenance And Calibration From The Distributor’s Qualified Engineer During The Warranty Period. 12. At Least A 2-year Warranty On Parts And Services. The Warranty Period Shall Commence From The Date Of Acceptance By The End-user, Testing, And Commissioning. 13. The Bidder Must Submit Certification That They Have The Capability For Corrective And Preventive Maintenance Of The Unit. 14. Availability Of Trained Service Engineers With Guaranteed Uptime Within 48 Hrs For Troubleshooting And Repair Of Unit Even After The Warranty Period. 15. Provide Operator’s And Service Manual (in English) Upon Delivery. 16. Price Should Be Inclusive Of All Applicable Taxes. Hot Wire Anemometer With Sd Card Logger General Specifications: - Can Read The Following Units Of Measurements: - Ft/min: 40 To 3940 - Km/h: 0.4 To 38.8 - Mph: 0.2 To 25.0 - Knots: 0.7 To 72.0 - M/s: 0.5 To 44.7 - Type K: -50 To 1300°c - Type J: -50 To 1100°c - Air Temp: 0 To 5°c - Handheld Size But With Comes With A Fold-out Tripod - With Low Battery Indicator - With Hold Function - Has Auto Power Off Feature - With Backlit Lcd Inclusions: - Soft Carrying Case - Detachable Probe - 6 Aa Batteries - Instruction Manual - Sd Card With 32 Gb Memory Or More Terms And Conditions: 1. Supplier Shall Indicate Brand, Model, And Country Of Origin. 2. The Supplier Will Provide A Notarized Certificate Indicating That The Product Is Brand New, Not Reconditioned/refurbished Including Parts And Accessories. 3. Comes With Free Delivery To The Institute Of Pharmaceutical Sciences, National Institutes Of Health, Up Manila Which Should Be Done Within 60-90 Days Upon Acceptance Of Notice To Proceed. Note That Acknowledgment By The Supplier Through Email Constitutes The Date Of Acceptance. 4. The Supplier Will Witness And/or Help The Unpacking Of The Equipment To Ensure That All Items Are Included Inside And In Good Condition. 5. Qualified Service Engineer/s Must Perform Equipment Start-up, Testing, Operation, And/or Installation With Proper Documentation And Report. 6. The Equipment Must Be Delivered And Ready To Use. Connectors, Adapters, And/or Accessories Even Not Specified But Are Essential For The Unit To Function Must Be Provided Free By The Winning Bidder. 7. Certification From The Manufacturer/local Distributor That In The Event Of A Change Of Local Distributor, Preventive Maintenance, Warranty, And Services Agreed Here Upon Will Be Honored By The Principal Manufacturer. 8. Certification Or Guarantee Letter From The Manufacturer/local Distributor To Ensure The Availability Of Parts, Supplies, And Accessories Will Not Be Discontinued For The Next 10 Years. 9. Undertaking To Provide Product Orientation And Operations Training For End-users And Troubleshooting Training For Research Staff Within Seven Days After Completion Of Installation. 10. Provide Bi-annual Preventive Maintenance And Calibration From The Distributor’s Qualified Engineer During The Warranty Period. 11. At Least A 2-year Warranty On Parts And Services. The Warranty Period Shall Commence From The Date Of Acceptance By The End-user, Testing, And Commissioning. 12. The Bidder Must Submit Certification That They Have The Capability For Corrective And Preventive Maintenance Of The Unit. 13. Availability Of Trained Service Engineers With Guaranteed Uptime Within 48 Hrs For Troubleshooting And Repair Of Unit Even After The Warranty Period. 14. Provide Operator’s And Service Manual (in English) Upon Delivery. 15. Price Should Be Inclusive Of All Applicable Taxes. Refrigerated Centrifuge General Specifications: - Speed - Maximum Speed Is 18,000 Rpm (in 100-rpm Increments) - Maximum G-force Is 29,000 X G Or Higher - Actual Rotor Speed Should Only Be ± 50 Rpm Of Set Speed - Displayed Speed Should Be Actual Rotor Speed In 100-rpm Increments Or In Rcf - Time - Can Set Time Up To To 9:59 (h:min) Or Set In Continuous Mod - Has Hold And Pulse (short Run) Options - Time Is Either Displayed– Time Remaining In Run (timed Run ± 1 Min Accuracy) Or ∞ And Elapsed Time (continuous Run) - Temperature - Temperature Can Be Set From -20 To +40°c (in 1°c Increments) - Temperature Control (after Equilibration) Is At ± 2.5°c Of Set Temperature - Temperature Display (after Equilibration) – Chamber Temperature In 1°c Increments - Operating Range Is From 2 To 40°c - Ambient Temperature Range Is From 10 To 35°c - With Cfc-free Refrigeration System - Has 10 Acceleration And Deceleration Profiles - Mechanical And Electrical Requirements - Unit Should Weigh <80 Kg - Requires A Maximum Of 3 In. Clearance On All Sides - Noise Level 3 Ft In Front Of Instrument Should Be <68 Dba - Dimensions: Width Is 50 Cm Or Less, Depth Is 75 Cm Or Less, Height When Door Is Closed Should Be 40 Cm Or Less, Height When Door Open Should Be 82 Cm Or Less - Maximum Heat Dissipation Into Room Under Steady-state Conditions Should Be 3311 Btu/h (0.97 Kw) Or Less - Electrical Requirements: 220-240 Vac, 6.2 A, 50-60 Hz - Class I Electrical Supply Inclusions: - Compatible Avr - Fixed Angle Aluminum Rotor For 50 Ml Tubes - Fixed-angle Conical Tube Aluminum Rotor For 15 Ml Tubes - Biocontainment Aluminum Rotor For 2.0 Ml Tubes - Swinging Bucket Aluminum Rotor For Microplates And Deep Well Microplates Terms And Conditions: 1. Supplier Shall Indicate Brand, Model, And Country Of Origin. 2. The Supplier Will Provide A Notarized Certificate Indicating That The Product Is Brand New, Not Reconditioned/refurbished Including Parts And Accessories. 3. Comes With Free Delivery And Installation To The Institute Of Pharmaceutical Sciences, National Institutes Of Health, Up Manila Which Should Be Done Within 60-90 Days Upon Acceptance Of Notice To Proceed. Note That Acknowledgment By The Supplier Through Email Constitutes The Date Of Acceptance. 4. The Supplier Will Witness And Help The Unpacking Of The Equipment To Ensure That All Items Are Included Inside And In Good Condition. 5. Free Relocation And Re-setup Of Equipment If Requested By The End-user Within The University Of The Philippines Manila Area Within The Warranty Period With Subsequent Installation Qualification And Operational Qualification With Documentation And Report. 6. Qualified Service Engineer/s Must Perform Equipment Start-up, Testing, Operation, And/or Installation With Proper Documentation And Report. 7. The Equipment Must Be Delivered And Ready To Use. Cables, Connectors, Adapters, And Accessories Even Not Specified But Are Essential For The Unit To Function Must Be Provided Free By The Winning Bidder. 8. Certification From The Manufacturer/local Distributor That In The Event Of A Change Of Local Distributor, Preventive Maintenance, Warranty, And Services Agreed Here Upon Will Be Honored By The Principal Manufacturer. 9. Certification Or Guarantee Letter From The Manufacturer/local Distributor To Ensure The Availability Of Parts, Supplies, And Accessories Will Not Be Discontinued For The Next 10 Years. 10. Undertaking To Provide Product Orientation And Operations Training For End-users And Troubleshooting Training For Research Staff Within Seven Days After Completion Of Installation. 11. Provide Bi-annual Preventive Maintenance And Calibration From The Distributor’s Qualified Engineer During The Warranty Period. 12. At Least A 2-year Warranty On Parts And Services. The Warranty Period Shall Commence From The Date Of Acceptance By The End-user, Testing, And Commissioning. 13. The Bidder Must Submit Certification That They Have The Capability For Corrective And Preventive Maintenance Of The Unit. 14. Availability Of Trained Service Engineers With Guaranteed Uptime Within 48 Hrs For Troubleshooting And Repair Of Unit Even After The Warranty Period. 15. Provide Operator’s And Service Manual (in English) Upon Delivery. 16. Price Should Be Inclusive Of All Applicable Taxes. Emergency Response Kit General Specifications: - Contains A Portable Spill Kit And First Aid Kit - The Portable Spill Kit Should Include The Following Items Packed In A Reusable Bag With Shoulder Strap - 32 Pcs Of 15 In. X 17-19 In. General Purpose Pads - 5 Pcs Of 3 In. X 4 Ft. Universal Socs - 1 Pc Of 18 In. X 18 In. Universal Absorbent Pillows - 1 Pair Of Nitrile Gloves - 2 Disposable Bags - 1 Pc Of Goggles - 1 Instruction Sheet - The First Aid Kit Should Include The Following Items Packed In A Bag With Handle - Gauze Pad 3x3 Inches (at Least 2pcs) - Gauze Pad 4x4 Inches (at Least 2pcs) - Gauze Bandage 3x10 Inches - Elastic Bandage - Triangular Cotton Bandage - Facemask - Aluminum Whistle - Alcohol At Least 60 Ml - Adhesive Bandage Strip (at Least 10pcs) - Povidone Iodine Pads (at Least 4pcs) - Alcohol Applicator Pad (at Least 10pcs) - Povidone Applicator Stick (at Least 5pcs) - Rubber Tourniquet - Cpr Barrier - Thermal Blanket - Surgical Tape - Burn Ointment - Instant Ice Pack - Tweezers - At Least 10 Pcs Of Safety Pins - Pocket Flashlight - Scissors Terms And Conditions: 1. Supplier Shall Indicate Brand, Model, And Country Of Origin. 2. Supplier Will Provide A Notarized Certificate Indicating That The Items Included Are Brand New And Not Reconditioned/refurbished. 3. Comes With Free Delivery To The Institute Of Pharmaceutical Sciences, National Institutes Of Health, Up Manila Which Should Be Done Within 60-90 Days Upon Acceptance Of The Notice To Proceed. Note That Acknowledgment By The Supplier Through Email Constitutes The Date Of Acceptance. 4. The Supplier Will Help Unpack The Bags To Ensure That All Items Are Included Inside And Are In Good Condition. 5. Price Should Be Inclusive Of All Applicable Taxes. Laboratory Water Bath General Specifications: - Dimensions (w X L X H) Are 68-72 X 33-37 X 24-28 Cm - Filling Volume Is Maximum Of 20l - Usable Immersion Depth Is Maximum Of 18 Cm - Bath Tank Is Made Of Stainless Steel - Usable Bath Opening Is At Least (w X L / D) Is 50 X 30 / 18 Cm Features: - Has Shaking Feature - Shaking Frequency (linear) Is 20 To 200 Rpm - Shaking Stroke Is At 15 Mm - Has Temperature Control - Uses Pid1 Microprocessor Temperature Control - Temperature Display Is Led - Has Keypad For Temperature Setting - Working Temperature Range Is At 20 To 100 °c - Temperature Stability Is At ±0.2 °c - Ambient Temperature Ranges From 5 To 40 °c - Splash-proof Design - Warning And Cut-off Protection For High/low Temperature - Comes With Bath Drains At The Bottom Portion Of The Unit - Electronic Timer For Setting The Running Time From 0:01 To 9:59 (h:min) - Has Removable Shaking Carriage - Provides Dry-running Protection With Audible And Optical Alarm - Has Removable Platform For Full Immersion Of The Sample Containers - Has Atc3 (absolute Temperature Calibration) 1-point-calibration - Has High-temperature Stability Inclusions: - Lift-up Cover - Basic Tray For Assembling Erlenmeyer Flasks From 25 To 1000 Ml Including Spring Clamps - Compatible Test Glass Insert 16/17 Mm Ø For 50 Test Tubes - Compatible Test Glass Insert 30 Mm Ø For 21 Test Tubes Terms And Conditions: 1. Supplier Shall Indicate Brand, Model, And Country Of Origin. 2. The Supplier Will Provide A Notarized Certificate Indicating That The Product Is Brand New, Not Reconditioned/refurbished Including Parts And Accessories. 3. Comes With Free Delivery And Setup To The Institute Of Pharmaceutical Sciences, National Institutes Of Health, Up Manila Which Should Be Done Within 60-90 Days Upon Acceptance Of Notice To Proceed. Note That Acknowledgment By The Supplier Through Email Constitutes The Date Of Acceptance. 4. The Supplier Will Witness And Help The Unpacking Of The Equipment To Ensure That All Items Are Included Inside And In Good Condition. 5. Free Relocation And Re-setup Of Equipment If Requested By The End-user Within The University Of The Philippines Manila Area Within The Warranty Period With Subsequent Installation Qualification And Operational Qualification With Documentation And Report. 6. Qualified Service Engineer/s Must Perform Equipment Start-up, Testing, Operation, And/or Installation With Proper Documentation And Report. 7. The Equipment Must Be Delivered And Ready To Use. Cables, Connectors, Adapters, And Accessories Even Not Specified But Are Essential For The Unit To Function Must Be Provided Free By The Winning Bidder. 8. Certification From The Manufacturer/local Distributor That In The Event Of A Change Of Local Distributor, Preventive Maintenance, Warranty, And Services Agreed Here Upon Will Be Honored By The Principal Manufacturer. 9. Certification Or Guarantee Letter From The Manufacturer/local Distributor To Ensure The Availability Of Parts, Supplies, And Accessories Will Not Be Discontinued For The Next 10 Years. 10. Undertaking To Provide Product Orientation And Operations Training For End-users And Troubleshooting Training For Research Staff Within Seven Days After Completion Of Installation. 11. Provide Bi-annual Preventive Maintenance And Calibration From The Distributor’s Qualified Engineer During The Warranty Period. 12. At Least A 2-year Warranty On Parts And Services. The Warranty Period Shall Commence From The Date Of Acceptance By The End-user, Testing, And Commissioning. 13. The Bidder Must Submit Certification That They Have The Capability For Corrective And Preventive Maintenance Of The Unit. 14. Availability Of Trained Service Engineers With Guaranteed Uptime Within 48 Hrs For Troubleshooting And Repair Of Unit Even After The Warranty Period. 15. Provide Operator’s And Service Manual (in English) Upon Delivery. 16. Price Should Be Inclusive Of All Applicable Taxes. Vortex Mixer And Accessories General Specifications: - Mixing Frequency Ranges From 300-3000 Rpm - Dimensions (w X D X H) Should Be Less Than 22 X 32 X 15 Cm - Weighs Less Than 7 Kg - Ø Of Mixing Orbit Is 3 Mm - Has A Timer That Ranges From 15 Sec To 99:30 Hours And Capable Of Continuous Mode - Has Mix Control, Anti-spill Technology, Short/interval Mix, Time/temp Mode, And Pause Function - Can Accommodate Various Sample Vessels And Plate Formats From 5 Μl To 50 Ml - Temperature Ranges From 15 °c Below Rt Up To 100 °c - Capable Of Heating, Mixing, And Cooling Accessories Included: - Compatible Holder For Microtiter Plates And Deep Well Plates With Suitable Lid/cover - Compatible Holder For 1.5 Ml Microtubes - Compatible Holder For 15 Ml Conical Tubes Terms And Conditions: 1. Supplier Shall Indicate Brand, Model, And Country Of Origin. 2. The Supplier Will Provide A Notarized Certificate Indicating That The Product Is Brand New, Not Reconditioned/refurbished Including Parts And Accessories. 3. Comes With Free Delivery And Setup To The Institute Of Pharmaceutical Sciences, National Institutes Of Health, Up Manila Which Should Be Done Within 60-90 Days Upon Acceptance Of Notice To Proceed. Note That Acknowledgment By The Supplier Through Email Constitutes The Date Of Acceptance. 4. The Supplier Will Witness And Help The Unpacking Of The Equipment To Ensure That All Items Are Included Inside And In Good Condition. 5. Free Relocation And Re-setup Of Equipment If Requested By The End-user Within The University Of The Philippines Manila Area Within The Warranty Period With Subsequent Installation Qualification And Operational Qualification With Documentation And Report. 6. Qualified Service Engineer/s Must Perform Equipment Start-up, Testing, Operation, And/or Installation With Proper Documentation And Report. 7. The Equipment Must Be Delivered And Ready To Use. Cables, Connectors, Adapters, And Accessories Even Not Specified But Are Essential For The Unit To Function Must Be Provided Free By The Winning Bidder. 8. Certification From The Manufacturer/local Distributor That In The Event Of A Change Of Local Distributor, Preventive Maintenance, Warranty, And Services Agreed Here Upon Will Be Honored By The Principal Manufacturer. 9. Certification Or Guarantee Letter From The Manufacturer/local Distributor To Ensure The Availability Of Parts, Supplies, And Accessories Will Not Be Discontinued For The Next 10 Years. 10. Undertaking To Provide Product Orientation And Operations Training For End-users And Troubleshooting Training For Research Staff Within Seven Days After Completion Of Installation. 11. Provide Bi-annual Preventive Maintenance And Calibration From The Distributor’s Qualified Engineer During The Warranty Period. 12. At Least A 2-year Warranty On Parts And Services. The Warranty Period Shall Commence From The Date Of Acceptance By The End-user, Testing, And Commissioning. 13. The Bidder Must Submit Certification That They Have The Capability For Corrective And Preventive Maintenance Of The Unit. 14. Availability Of Trained Service Engineers With Guaranteed Uptime Within 48 Hrs For Troubleshooting And Repair Of Unit Even After The Warranty Period. 15. Provide Operator’s And Service Manual (in English) Upon Delivery. 16. Price Should Be Inclusive Of All Applicable Taxes. Ultrasonic Waterbath General Specifications: - Tank Capacity Is 9.5 L With The Following Dimensions (l X W X D) 11-13 X 9-11 X 5-7 Inches - Overall Size Of The Equipment Should Be Around (l X W X D) 15-17 X 15-17 X 14-16 Inches - Frequency Should Be At 40 Khz - Needs To Have A Drain - Comes With A Cover - Has 40 Khz Rugged Industrial Transducers With Sweep Frequency - With Heater That Heat Up To 69°c - Has A Dual Power And Power Tracking - Has A Sleep Mode - Capable Of Degas Wave Modulation And Auto Ultrasonics Activation - Has High Temperature Alarm - Front Panel Auto Temp Calibration - Body Is Made Of Chemical-resistant Plastic Inclusions: - Compatible Perforated Tray - Compatible Mesh Basket - Compatible Beaker Positioning Cover - Compatible Solid Insert Tray - Compatible Support Rack Terms And Conditions: 1. Supplier Shall Indicate Brand, Model, And Country Of Origin. 2. Supplier Will Provide A Notarized Certificate Indicating That The Product Is Brand New, Not Reconditioned/refurbished Including Parts And Accessories. 3. Comes With Free Delivery And Setup To The Institute Of Pharmaceutical Sciences, National Institutes Of Health, Up Manila Which Should Be Done Within 60-90 Days Upon Acceptance Of Notice To Proceed. Note That Acknowledgment By The Supplier Through Email Constitutes The Date Of Acceptance. 4. The Supplier Will Witness And Help The Unpacking Of The Equipment To Ensure That All Items Are Included Inside And In Good Condition. 5. Free Relocation And Re-setup Of Equipment If Requested By The End-user Within The University Of The Philippines Manila Area Within The Warranty Period With Subsequent Installation Qualification And Operational Qualification With Documentation And Report. 6. Qualified Service Engineer/s Must Perform Equipment Start-up, Testing, Operation, And/or Installation With Proper Documentation And Report. 7. The Equipment Must Be Delivered Ready To Use. Cables, Connectors, Adapters, And Accessories Even Not Specified But Are Essential For The Unit To Function Must Be Provided Free By The Winning Bidder. 8. Certification From The Manufacturer/local Distributor That In The Event Of A Change Of Local Distributor, Preventive Maintenance, Warranty, And Services Agreed Here Upon Will Be Honored By The Principal Manufacturer. 9. Certification Or Guarantee Letter From The Manufacturer/local Distributor To Ensure The Availability Of Parts, Supplies, And Accessories And Will Not Be Discontinued For The Next 10 Years. 10. Undertaking To Provide Product Orientation And Operations Training For End-user And Troubleshooting Training For Research Staff Within Seven Days After Completion Of Installation. 11. Provide A Bi-annual Preventive Maintenance And Calibration From The Distributor’s Qualified Engineer During The Warranty Period. 12. At Least 2-year Warranty On Parts And Services. The Warranty Period Shall Commence From The Date Of Acceptance By The End-user, Testing, And Commissioning. 13. The Bidder Must Submit Certification That They Have The Capability For Corrective And Preventive Maintenance Of The Unit. 14. Availability Of Trained Service Engineers With Guaranteed Uptime Within 48 Hrs For Troubleshooting And Repair Of Unit Even After The Warranty Period. 15. Provide Operator’s And Service Manual (in English) Upon Delivery. 16. Price Should Be Inclusive Of All Applicable Taxes. Laboratory Refrigerator General Specifications: - External Dimensions Measure 708-802 X 463-467 X 1088-1092 Mm (w X D X H) - Internal Dimensions Measure 718-722 X 298-302 X 723-727 Mm (w X D X H) - Volume Capacity Is 150 Liters Or More - External Cabinet Is Made With Galvanised Steel With Baked-on Finish - Internal Cabinet Is Made With Stainless Steel - Has Sliding Glass Doors Made With Double-glazing Glass And Heat-reflective Film - The Shelves Are Made Of Hard Steel Wire - Insulation Material Is Polyurethane Foam - Has Hfc Refrigerant - Has Led/2 Casters For Lighting - Mechanical Components Are As Follows: - Access Port: Ø30 Mm On Back Wall - Compressor: Hermetic Type, 90w - Evaporator: Fin & Tube, Forced-air Circulation - Condenser: Wire & Tube - Defrosting: Cyclical Defrosting And Evaporator Temp. Detection System - Defrosting Heaters: 87w - Temperature Control Ranges From 2 To 14 °c - Temperature Is Displayed Digitally With 1°c Increments When Adjusted - Unit Should Have An Alarm System To Indicate Changes In The Set Temperature Value - Unit Should Have Buzzer And/or Door Ajar Lamp - Rohs Compliant Inclusions: - With Compatible Avr Terms And Conditions: 1. Supplier Shall Indicate Brand, Model, And Country Of Origin. 2. The Supplier Will Provide A Notarized Certificate Indicating That The Product Is Brand New, Not Reconditioned/refurbished Including Parts And Accessories. 3. Comes With Free Delivery And Installation To The Institute Of Pharmaceutical Sciences, National Institutes Of Health, Up Manila Which Should Be Done Within 90-120 Days Upon Acceptance Of Notice To Proceed. Note That Acknowledgment By The Supplier Through Email Constitutes The Date Of Acceptance. 4. The Supplier Will Witness And/or Help The Unpacking Of The Equipment To Ensure That All Items Are Included Inside And In Good Condition. 5. Free Relocation And Re-setup Of Equipment If Requested By The End-user Within The University Of The Philippines Manila Area Within The Warranty Period With Subsequent Installation Qualification And Operational Qualification With Documentation And Report. 6. Qualified Service Engineer/s Must Perform Installation Qualification And Operational Qualification With Documentation And Report. 7. The Equipment Must Be Delivered Ready To Use. Cables, Connectors, Adapters, And Accessories Even Not Specified But Are Essential For The Unit To Function Must Be Provided Free By The Winning Bidder. 8. Certification From The Manufacturer/local Distributor That In The Event Of A Change Of Local Distributor, Preventive Maintenance, Warranty, And Services Agreed Here Upon Will Be Honored By The Principal Manufacturer. 9. Certification Or Guarantee Letter From The Manufacturer/local Distributor To Ensure The Availability Of Parts, Supplies, And Accessories And Will Not Be Discontinued For The Next 10 Years. 10. Undertaking To Provide Product Orientation And Operations Training For End-user And Troubleshooting Training For Research Staff Within Seven Days After Completion Of Installation. 11. Provide A Bi-annual Preventive Maintenance And Calibration From The Distributor’s Qualified Engineer During The Warranty Period. 12. At Least 2-year Warranty On Parts And Services. Warranty Period Shall Commence From The Date Of Acceptance By The End-user, Testing, And Commissioning. 13. The Bidder Must Submit Certification That They Have The Capability For Corrective And Preventive Maintenance Of The Unit. 14. Availability Of Trained Service Engineers With Guaranteed Uptime Within 48 Hrs For Troubleshooting And Repair Of Unit Even After The Warranty Period. 15. Provide Operator’s And Service Manual (in English) Upon Delivery. 16. Price Should Be Inclusive Of All Applicable Taxes. Water Filtration System With Vacuum Pump General Specifications: - All-in-one Filtration System - Has Vacuum Source With Filtration Apparatus - Oil-free - With Vacuum Regulator And Thermal Protection - Chemical Resistant - Has Maximum Vacuum Of 99 Mbar Abs. - Has Maximum Flow Rate Of 20l/min - Noise Level Is At 50 Db - Hose Barb Size Is Id8 (5/16 Inch) - Dimensions (l X W X H): 32-36 X 22-26 X 28-32 Cm - Electrical Data Are As Follows: - Max Power: 60w - Max Current: 0.3a - Comes With 2 Sets Of Glass Filtration Apparatus With The Following Specifications: - Funnel And Support Base Is Made Of Borosilicate Glass - Funnel Capacity Is 300 Ml - Membrane Support Is Made Of Sintered Glass - Clamp Is Made Of Aluminum - The Included Rubber Stopper Is Made Of Silicone Rubber (no. 8) - Filtration Adaptor Is Made Of Pp Material - The Filter Diameter Is 47 Mm - The Storage Bottle Should Be Made Of Borosilicate Glass And Has 1000 Ml Storage Capacity With Id8 Hose Barb Inclusions: - Comes With 1 Pack Of 47 Mm Membrane Filter Terms And Conditions: 1. Supplier Shall Indicate Brand, Model, And Country Of Origin. 2. The Supplier Will Provide A Notarized Certificate Indicating That The Product Is Brand New, Not Reconditioned/refurbished Including Parts And Accessories. 3. Comes With Free Delivery And Setup To The Institute Of Pharmaceutical Sciences, National Institutes Of Health, Up Manila Which Should Be Done Within 60-90 Days Upon Acceptance Of Notice To Proceed. Note That Acknowledgment By The Supplier Through Email Constitutes The Date Of Acceptance. 4. The Supplier Will Witness And Help The Unpacking Of The Equipment To Ensure That All Items Are Included Inside And In Good Condition. 5. Free Relocation And Re-setup Of Equipment If Requested By The End-user Within The University Of The Philippines Manila Area Within The Warranty Period With Subsequent Installation Qualification And Operational Qualification With Documentation And Report. 6. Qualified Service Engineer/s Must Perform Equipment Start-up, Testing, Operation, And/or Installation With Proper Documentation And Report. 7. The Equipment Must Be Delivered Ready To Use. Cables, Connectors, Adapters, And Accessories Even Not Specified But Are Essential For The Unit To Function Must Be Provided Free By The Winning Bidder. 8. Certification From The Manufacturer/local Distributor That In The Event Of A Change Of Local Distributor, Preventive Maintenance, Warranty, And Services Agreed Here Upon Will Be Honored By The Principal Manufacturer. 9. Certification Or Guarantee Letter From The Manufacturer/local Distributor To Ensure The Availability Of Parts, Supplies, And Accessories And Will Not Be Discontinued For The Next 10 Years. 10. Undertaking To Provide Product Orientation And Operations Training For End-user And Troubleshooting Training For Research Staff Within Seven Days After Completion Of Delivery And/or Installation. 11. Provide A Bi-annual Preventive Maintenance And Calibration From The Distributor’s Qualified Engineer During The Warranty Period. 12. At Least 2-year Warranty On Parts And Services. The Warranty Period Shall Commence From The Date Of Acceptance By The End-user, Testing, And Commissioning. 13. The Bidder Must Submit Certification That They Have The Capability For Corrective And Preventive Maintenance Of The Unit. 14. Availability Of Trained Service Engineers With Guaranteed Uptime Within 48 Hrs For Troubleshooting And Repair Of Unit Even After The Warranty Period. 15. Provide Operator’s And Service Manual (in English) Upon Delivery. 16. Price Should Be Inclusive Of All Applicable Taxes. Automated Solid Phase Extraction Manifold General Specifications: - Gas Regulator And Gas Gauge Range: - Output: 0-30 Psi - Input: 100 Psi Maximum - Dimensions (hxwxd): 20-23 X 22-25 X 25-27 In - Sample Rack Dimensions (hxwxd): 6-8 X 16-18 X 10-13 In - With Operating System Software With 24 Default Methods Stored In The Software - Liquid Management - Air Syringe: One 10 Ml Air Syringe - Lh Syringe: One 10 Ml Liquid Handling Syringe - 12-port Rotary Valve With Sliding Seal - Stainless Steel Nozzle - With 6 Or More Sample Inlet And Are Made Of Tfe Tubing, 1/16” Id - Sample Pumps - Has Positive Displacement - Accuracy Is At +/- 2.5% - Ceramic Piston And Liner - Non Use Of Acetic Acid, Acetone - Has Various Spe Configurations - 1 Ml Syringe: Compatible Cartridges - 3 Ml Syringe: Compatible Cartridges - 6 Ml Syringe: Compatible Cartridges - Disk Version: 47 Mm Spe Disk Features: - Automates Sample Loading Of Liquids Onto Spe Cartridges - Automates Eluting Of Spe Cartridges With Organic Solvent - Has Closed Systems With Fan To Vent Solvent Vapors - Spe Technology For Liquid-liquid Extraction - Uses Positive Pressure Loading And Elution Of Samples And Solvents Terms And Conditions: 1. Supplier Shall Indicate Brand, Model, And Country Of Origin. 2. Supplier Will Provide A Notarized Certificate Indicating That The Product Is Brand New, Not Reconditioned/refurbished Including Parts And Accessories. 3. Comes With Free Delivery And Setup To The Institute Of Pharmaceutical Sciences, National Institutes Of Health, Up Manila Which Should Be Done Within 60-90 Days Upon Acceptance Of Notice To Proceed. Note That Acknowledgment By The Supplier Through Email Constitutes The Date Of Acceptance. 4. The Supplier Will Witness And/or Help The Unpacking Of The Equipment To Ensure That All Items Are Included Inside And In Good Condition. 5. Free Relocation And Re-setup Of Equipment If Requested By The End-user Within The University Of The Philippines Manila Area Within The Warranty Period With Subsequent Installation Qualification And Operational Qualification With Documentation And Report. 6. Qualified Service Engineer/s Must Perform Equipment Start-up, Testing, Operation, And/or Installation With Proper Documentation And Report. 7. The Equipment Must Be Delivered Ready To Use. Cables, Connectors, Adapters, And Accessories Even Not Specified But Are Essential For The Unit To Function Must Be Provided Free By The Winning Bidder. 8. Certification From The Manufacturer/local Distributor That In The Event Of A Change Of Local Distributor, Preventive Maintenance, Warranty, And Services Agreed Here Upon Will Be Honored By The Principal Manufacturer. 9. Certification Or Guarantee Letter From The Manufacturer/local Distributor To Ensure The Availability Of Parts, Supplies, And Accessories And Will Not Be Discontinued For The Next 10 Years. 10. Undertaking To Provide Product Orientation And Operations Training For End-user And Troubleshooting Training For Research Staff Within Seven Days After Completion Of Installation. 11. Provide A Bi-annual Preventive Maintenance And Calibration From The Distributor’s Qualified Engineer During The Warranty Period. 12. At Least 2-year Warranty On Parts And Services. The Warranty Period Shall Commence From The Date Of Acceptance By The End-user, Testing, And Commissioning. 13. The Bidder Must Submit Certification That They Have The Capability For Corrective And Preventive Maintenance Of The Unit. 14. Availability Of Trained Service Engineers With Guaranteed Uptime Within 48 Hrs For Troubleshooting And Repair Of Unit Even After The Warranty Period. 15. Provide Operator’s And Service Manual (in English) Upon Delivery. 16. Price Should Be Inclusive Of All Applicable Taxes. Here Upon Will Be Honored By The Principal Manufacturer. 9. Certification Or Guarantee Letter From The Manufacturer/local Distributor To Ensure The Availability Of Parts, Supplies, And Accessories And Will Not Be Discontinued For The Next 10 Years. 10. Undertaking To Provide Product Orientation And Operations Training For End-user And Troubleshooting Training For Research Staff Within Seven Days After Completion Of Installation. 11. Provide A Bi-annual Preventive Maintenance And Calibration From The Distributor’s Qualified Engineer During The Warranty Period. 12. At Least 2-year Warranty On Parts And Services. The Warranty Period Shall Commence From The Date Of Acceptance By The End-user, Testing, And Commissioning. 13. The Bidder Must Submit Certification That They Have The Capability For Corrective And Preventive Maintenance Of The Unit. 14. Availability Of Trained Service Engineers With Guaranteed Uptime Within 48 Hrs For Troubleshooting And Repair Of Unit Even After The Warranty Period. 15. Provide Operator’s And Service Manual (in English) Upon Delivery. 16. Price Should Be Inclusive Of All Applicable Taxes.
Contact
Tender Id
63fa9a4a-4978-35db-a804-5fa8d705d8abTender No
10980118Tender Authority
University Of The Philippines ViewPurchaser Address
-Website
https://www.up.edu.ph/