- Home/
- Philippines/
- Province Of Cavite/
- Overview
Province Of Cavite Tender
Province Of Cavite Tender
Costs
Summary
Purchase Of Various Medical Equipment For Use In Provincial And Satellite Hospitals , Medical And Dental Equipment ,province Of Cavite
Description
Description Supply And Delivery Of Various Medical Equipment For Use In Provincial And Satellite Hospitals 1. 4 Units Microscope Microscope Frame For Transmitted Microscopy With Led Illuminator, Binocular Tube, A Pair Of Eyeplace 10x (f,n,20), Quadruple Revolving Nosepiece, Right-handle Mechanical Stage, Abbe Condenser And Plan Objectives (4x, 10x, 40x, 100x), Including Ac Adapter, Fixing Belt Fot Transpormation. Oil Immersion 10ml - 2 Bottle Dust Cover-015w/print - Cover-015 (wp) Dust Cover Type-015 With Print Uycp - Power Cord Uycp Power Cord Features: Diverse, User-friendly Design Combined With Outstanding Optical Performance Operational Ese Across All Aspects Of Use Specifications: Body: Aluminium Die-casting Metal Frame, Protective Covering Optical System: Infinity Optical System Illumination System: Built-in Transmitted Illumination System, Led Power Consumption 0.5 W (nominal Values) Focusing: Stage Height Movement (coarse Movement Stroke: 15mm), Coarse Adjustment Limit Stopper, Torque Adjustment For Coarse Adjustment Knob, Fine Focus Knob (minimum Adjustment Gradations: 2.5µm) Revolving Nosepiece: Fixed Quadruple Nosepiece Stage: Wire Movement Mechanical Fixed Stage Traveling Range: 76mm (x) X 30mm (y), Specimen Holder, Specimen Position Scale Observation Tube: 30⁰ Inclined Binocular Tube Interpupillary Distance Adjustment Range: 48 - 75 Mm, Eyepoint Adjustment: 370.0 - 432.9 Mm Objestives: Plan Achromat, Anti-fungus 4x Na 0.10 W.d.: 27.8mm 10x Na: 0.25 W.d.: 8.0mm 40x Na: 0.65 W.d.: 0.6 Mm 100xoil Na: 1.25 W.d.: 0.13 Mm (cx23ledrfs1 Only) Eyepiece (10x): Field Number (fn): 20 (anti-fungus) Weight Approx. 5.9 Kg Rated Voltage/electric Current Ac 100-240 V 56/60 Hz 0.4 A Power Consumption: Less Than 2 W 2. 1 Unit Video Laryngoscope 3l Video Laryngoscope Host/pocket Monitor Features: Universal Host That Could Accommodate All Laryngoscope Handles Such As Video Laryngoscopes, Video Rigid Laryngoscopes, And Video Flexible Laryngoscopes. Supports Connection By Micro-usb And Hdmi Cable. With At Least 8gb Internal Memory And Must Have Screen Access For Image Capturing/video Recording. With Built-in Non-removable Lithium Polymer Battery That Lasts Approximately 240 Minutes Working Time, Charging Time Not More Than 4 Hours, With Service Life Of Not Less Than 5 Years. With At Least 3.5” Lcd Medical Resistance Touchscreen Monitor, No Less Than 640x480 Resolution Display. Can Be Tilted ≥130º And Rotated Up To 270º. Icon Indicators For Battery, Operating Time, And Menu Setting. Able To Display Captured Photo And Video With Audio. With Incorporated Quick-guide Training Video For Users. Ready Ports For Data Transmission And Hdmi For External Display Monitor Connection. Configurable Settings For Date And Time, Brightness Setting, Volume Level, Hdmi Connection, Recording, System Information, And Formatting. Supports Video With Audio Recording, And The Ability To Save Photos Of The Live Display From Camera, Apply Full Digital Imaging Technology. Includes Alcohol-based Rapid Disinfectant With Tuberculocidal Effect, Active Against Enveloped Viruses Contains Propan-2-ol, Propan-1-ol And N-(3-aminopropyl)-n-dodecylopropane- 1, 3-diamine, Certified Vah, And Efficacy Based On Dghm Methods. Host Specifications: : 103-110x 104-110x 20-30 Mm : ≤170g : 3.5-inch Lcd Touchscreen, Has Built-in Battery Non-removable : Tilt ≥130 º Rotation 0 º~270 º : 160 Degrees : Photography/ Video (with Sound) Record And Playback : 8 Gb : Direct Connection Thru Detach Button : Micro-usb Connection Port Micro-hdmi Connection Port : Lithium Polymer Lasts Approximately 4 Hours, 2500 Mah : Charging Will Take No More Than 4 Hours. : 5 Years’ Service Life : Dc3.7v 3. 1 Unit Gas Analyzer With Capnograph Display • Type: High-contrast Amber Electroluminescent Display With Excellent Vertical And Horizontal Viewing Angles • Display Size: 5” Diagonal 4.25” X 2.28” (127 Mm Diagonal 108 X 58 Mm) • Graphic Display Of Co2: Waveform • Numeric Display: Fractional Inspiratory Concentration (fi) Of Co2, N2o And Of Selected Agent, End-tidal Concentration (fet) Of Co2, N2o And Selected Agent Co2 • Sidestream Sample Flow Rate: 150 Ml/min ±20 Ml/min • Measuring Range: 0 To 10.0 Vol.% / Kpa, 0 To 75 Mmhg • Prevision: ±0.5% Vol.% / Kpa Or ± 12 % Rel. Whichever Is Greater; ±4 Mmhg Or ±12% Rel., Whichever Is Greater • Resolution: 1 Mmhg / 0.1 Vol.% / 0.1 Kpa Anesthetic Gas Measurement • Sidestream Samle Flow Rate: 150 Ml/min ±20 Ml/min • Response Time: <500 Ms • Display Range For N2o: 0 To 99% Vol.% • Display Range For Halothane: 0 To 8.5 Vol.%• Display Range For Isoflurane: 0 To 8.5 Vol.%• Display Range For Enflurane: 0 To 10 Vol.%• Display Range For Sevoflurane: 0 To 10 Vol.%• Display Range For Desflurane: 0 To 22 Vol.%• Warm-up Phase: 4 Minutes Spo2 • Oxygen Saturation Spo2: 1 To 100% • Resolution: 1% • Pulse Rate: 20 To 250/min • Resolution: 1/min Interfaces • Rs 232 C • Medibus Rs 232 C Power Supply: 100-240 Vac, 60 Hertz Features: A Variable Anesthetic Gas Monitor Used For Measuring And Monitoring The Co2 Concentration, Functional Oxygen Saturation, Pulse Rate, And The Concentrations Of N2o, And The Following Volatile Anesthetic Agents: Halothane, Enflurane, Isoflurane, Sevoflurane, And Desflurane. The Display Shows Real-time Curve Co2, Inspiratory Concentration Fico2, End-expiratory Concentration Fetco2, Functional Oxygen Saturation Spo2, Pulse Rate, Inspiratory Concentration Fin2o, End-expiratory Concentration Fetn2o, And The Concentrations Of Anesthetic Agents. Inferred Light Measurement From Sidestream Samples. Measured Parameters: Co2, N2o, Spo2, And 5 Anesthetic Agents. Gas Measurement: Breath-to-breath Resolution. High-contrast Amber Electroluminescent Display. 5” Diagonal Display. 4. 1 Unit Tci Syringe Pump Dimension: 412 X 75 X 142mm (wxhxd) Weight: 1.7kg (battery Incuded) Classification: 1. Class I / Internally Powered Equipment; 2. Defibrillation-proof Type Cf Applied Part; 3. Ip33; 4. Not Sterilized; 5. Not Category Ap / Apg Equipment; 6. Mode Of Operation: Continuous Screen Size: 3-inch Lcd With A Resistive Touch Screen 10 Levels Brightness Adjustments Standby Function Night Mode: A Different Brightness And Volume Are Set For Night Mode. Screen Lock Function Accessories: Power Cord, Handle, Pole, Clamp Pca Controller Nurse Call Barcode Reader (the Patient/drug Information Can Be Input Through The Barcode Scanner.) Compatible Syringe: Various Brands Of 2ml, 3ml, 5ml, 10ml, 20ml, 30ml, And 50 (60)ml Compliant With The Iso 7886-1: Sterile Hypodermic Syringes For Single Use-part 1: Syringes For Manual Use. Parameters Infusion Mode: Rate Mode, Time Mode, Weight Mode, Sequence Mode, Trapezia Mode, Micro Mode, Loadingdose Mode, Tiva Mode, Pca Mode (optional), Tci Mode, And Intermittent Mode Infusion Rate Range: 0.1 - 60.0ml/h (2ml Syringe) 0.1 - 90.0ml/h (3ml Syringe) 0.1 - 159.0ml/h (5ml Syringe) 0.1 - 300ml/h (10ml Syringe) 0.1 - 600.0ml/h (20ml Syringe) 0.1 - 900.0ml/h (30ml Syringe) 0.1 - 2000.0ml/h (50/50ml Syringe) Increment: 0.1 - 99.9ml/h (increments 0.01ml/h) 1000 - 2000ml/h (increments 1ml/h) 100 - 999.9ml/h (increments 0.1ml/h) Vtbi 0.10~9999.99ml (minimum Increment: 0.01ml) Present Time: 00:00:01 - 99:59:59 (h:m:s) Adjustable, Increment 1s Accumulated Time: 0.00 - 99999.99 Infusion Accuracy: Infusion Accuracy ≤±2% Mechanical Accuracy ≤±0.5% Kvo Rate: 0.10~5.00ml/h (minimum Increment: 0.01ml/h) Bolus & Purge Rate: 0.1-60.0 Ml/h (2ml Syringe) 0.1-150.0ml/h (5ml Syringe) 0.1-600.0ml/h (20ml Syringe) 0.1-2000.0ml/h(50/60ml Syringe) 0.1-90.0ml/h (3ml Syringe) 0.1-300.0ml/h (10ml Syringe) 0.1-900.0ml/h(30ml Syringe) 3 Bolus Ways Selectible: Automatic/manual/semi-auto Bolus Occlusion Level: 12 Levels Selectable, 150mmhg-975mmhg Special Function Recent Therapy: 20 Recent Therapies Are Recorded And Can Be Used For Rapid Infusion Event Recorded: Maximum Of 3,000 Historical Events Drug Library: 5,000 Drug Types Can Be Stored Sound: Sound Volume: 5 Levels Are Available For Selection. Power Supply: Power Supply Mode Switching: The Power Supply Mode Of The Syringe Pump Automatically Switches To Battery Mode In Case Of An Ac/dc Power Failure. Online Infusion: The Infusion Rate Can Be Changed During Infusion. Save Parameters: Key Parameters Are Saved Upon Power Failure Text Size: Three Levels Of Text Size Are Available For Selection Permission Management: Different Permissions Are Assigned To Allow Or Prohibit Various Operations, For Example, Changing Or Viewing Data. Networking Function: The Syringe Pump Can Be Connected To The Infusion Central Monitoring System Through The Wired Networking Function. Main Safety Standards: Iec 60601-1 Medical Electrical Equipment – Part 1: General Requirements For Basic Safety And Essential Performance Iec 60601-2-24 Medical Electrical Equipment – Part 2-24: Particular Requirements For The Basic Safety And Essential Performance Of Infusion Pumps And Controllers Iec60601-1-8 Medical Electrical Equipment – Part 1-8: General Requirements For Basic Safety And Essential Performance -collateral Standard: General Requirements ,tests And Guidance For Alarm Systems In Medical Electrical Equipment And Medical Electrical Systems Iec 60601-1-2 Medical Electrical Equipment – Part 1-2: General Requirements For Basic Safety And Essential Performance –collateral Standard : Electromagnetic Disturbances –requirements And Tests Alarm Message: Three Alarm Levels: High, Middle, And Low High Level Alarms: Infusion End, Bat Empty, Patient Side Occl, Infusion End Kvo Start, Kvo End, Relay Failed, Syringe Empty, Holder Error, Drive Head Err, And Err 00x Middle Level Alarm: Standby End Low Level Alarms: Infusion Near End, No Battery, No Ac Power, Bat Low, Reminder Alarm, And Syringe Near Empty Sound Alarm Level: From 45 Db To 85 Db. 5. 2 Units Electro Cautery Machine Electrosurgical Two-pedal Foot Switch, Cable 5mm, 6 Inch Plug Neutral Silicon Electrode, Reusable, For Adults 30×17cm, Cable 4m, Eu/6.3mm Plug Electrode Handles 4mm, Large, 2 Switches, Cable 4mm, 3-pin Plug. Lancet Electrode ,straight, Oval Shape, 25×3.5mm, Handle 4mm Knife Electrode, Straight, And 25mm, Handle 4mm Needle Electrode, Straight, 0.7mm, Handle 4mm. Ball Electrode, Straight, 2mm, Handle 4mm. Spatula Electrode, Oval Shape, Straight, 2×24mm, Handles 4mm Bipolar Forceps, Straight, 1mm, Length 160mm.bipolar Cable, Length 3m, Straight Connecter, 2 Pin, 29mm Plug. 6. 2 Units Heavy Duty Suction Machine 90liters/min With 4 Liter X2 Autoclavable Jars In Policarbonate Motor Power Feeding Iso 10079-1 Classification - Oiless And Maintenance-free Piston Pump Max Vacuum (adjustable) - 230v-60hz Max Free Air Flow Rate - High Vacuum / High Flow Noise Level - -0.90 Bar -90 Kpa -675 Mmhg Duty Cycle - 90 I/min Weight - 46,4 Dba Size - Non-stop Operation Made - Kg 20 Cm 46 X 85 X 42 7. 1 Unit Anesthesia Machine Features: 1. Main Gas Supply - Oxygen, Air, Nitrous 2. Pin Index Supply System - Oxygen, Air, Nitrous 3. Intended Patient Use - Adults, Pediatric, And Neonates 4. Ventilator - Machine Must Be Able To Ventilate Patient Using The Preset Settings Provided By The End-user Even Presence Of Driving Gas Is Temporarily Unavailable. High Quality Ventilation Capabilities Made Possible By Its High Accurate, Electronically Driven Piston Ventilator. Manual/spontaneous (man/spontaneous) Volume-controlled: Time Controlled (vc-cmv) Pressure-controlled: Time Controlled (pc-cmv) Volume-controlled, (vc-cmv/af) Volume-controlled, Synchronized (vc-simv) Pressure-controlled, Synchronized (pc-simv) Autoflow, Synchronized (vc-simv/af) Cpap / Psvexternal Fresh-gas Outlet 5. Fresh-gas Delivery - Mechanically Controlled Gas Mixer With Electronic Flow Measurement, Numerical Gas Flow Indicators And Virtual Flow Meters. Fresh-gas Flow (fg Flow) 0 To Atleast 12 L/min (o2, Air, And N2o). O2 Concentration (fg O2) 21 To 100vol%. O2 Flush 25 To 75 L/min At 2.7 To 6.9 Kpa X 100 (39 To 100 Psi; 0.27 To 0.69 Mpa) Supply Pressure. 6. Breathing System - Heated Breathing System For Low-flow And Minimum-flow Applications. Total Volume Approx. 3.65 L (incl. Co2 Absorber When Applying A Maximum Tidal Volume Of 1,500 Ml). Cleaning, Disinfection, Replaceable Without Tools, Less Than 11 Individual Components During Reprocessing, Design Optimized For Easy And Effective, Hygienic Reprocessing. With Bypass Valve Located In Breathing System Allowing Contiuous Machine Operation While Changing Co2 Absorber. With Fresh-gas Decoupling Valve That Prevents Direct Entry Of Pressure In The Patient Airway When Pressing The O2 Flush Button, Peep And Pressure Limitation. With Pup Off Pressure Release Valve Located At The Apl Valve. 7. Vaporizer - With Two (2) Vaporizer Mounting. With One (1) Unit Sevoflurane Vaporizer. Vaporizer Must Have No Cloth Component Which Allows Item To Be Functional Immediately Even Transporting It In An Upside Down Position. 8. Systems And Displays - 15.3" (38.9 Cm) Touchscreen, Configurable Screen Contents, Front Panel With Lc Display Of Airway Pressure, Supply Status Of Battery And Gases (cgs + Cylinders). Display Of Graphical Trends Or Mini-trends Simultaneously With Real-time Curves And Volume-pressure Loop; Additional Data Export Functions Via Usb Storage Device. 9. Ventilation Monitoring - Minute Volume (mv) And Tidal Volume (vt And ∆vt); Respiratory Rate (frequency); Peak Inspiratory Pressure (pip), Plateau Pressure (pplat), Mean Airway Pressure (pmean), Peep; Dynamic Compliance (cdyn), Resustance (r), Elastance (e), External Pressure Gauge For Indicating The Pressure In The Internal Breathing System. Bar Diagram Display Of Volume And Tidal Volume, Simultaneous Display Of 2 Loops: Volume-pressure And Flow-volume, Reference Loop. 10. Gas Monitoring - Integrated Patient-gas Measurement Module. Inspiratory And Expiratory Gas Concentration Of O2, N2o, Co2 And Anaesthetic Agents, Automatic Identification Of Isoflurane, Sevoflurane, Desflurane, Halothane, Enflurane, Detection Of Anaesthetic Gas Mixtures, Age-correted Xmac Display; Sample Gas Returned To The Breathing Circuit. Displaying Fresh-gas Efficiency. Determination Of Consumption And Uptake (determination Of Uptake Only For Anaesthetics), Fresh-gas And Anaesthetic Per Case And Since Last Zeroing. 11. Advance And Safety Features - Integrated Device Checklist And Illustrated Step-by-step Instructions For Daily Machine Preparation. Man/spon Ventilation With Dosing Of O2, Air (n2o Option) And Anaesthetic Agents Possible Even When Swtiched Off (emergency Start-up). Backuo Manual Mode Allows The Direct Change To Manual Ventilation While Maintaining Gas And Ventilation Monitoring; O2, Air (n2o Option) And Anaesthetic Agents From Vaporisers Can Be Contiuously Delivered. Mechanical Ventilation With Ambient Air In Case Of Complete Failure Of The Gas Supply. 12. Other Functions And Features - Automatic Start-up And Self-test Of Machine Including Calibration Of All Sensors And Testing Of All Control Valves; Normally No User Action Necessary After Start Of Test. Cbm Mode (cardiac Bypass Mode). Breathing Bag As An Indicator Of Fresh-gas Deficiency And Leaks. Pause Mode For Short-term Interruptions Of Ventilation. Integrated, Dimmable Illumination Of Working And Documentation Surfaces. Central Brake, Smooth Running Castors.13. Power Input Data - Mains Voltage 100 To 240 V Ac At 50/60 Hz. Internal Battery Backup Time At Least 45 Min, Typically 120 Min.14. Parameters - Tidal Volume (vt) Required 5 To 1,500 Ml. Respiratory Rate (rr) 3 To 100/min. Inspiratory Time (ti) 0.2 To 10 S. Inspiratory Pressure (pinsp) Peep +5 To 80 Hpa (cmh2o). Pressure Limitation (pmax) Peep +10 To 80 Hpa (cmh2o). Trigger Threshold (trigger) 0.3 To 15 L/min. Inspiratory Flow (flow) Minimum 0.1 L/min, Maximum ≥160 L/min. Pressure Support Above Peep (∆psupp) Off, 3 To (80 - Peep) Hpa (cmh2o). Ratio Of Inspiratory Time To Expiratory Time (i:e) 1:50 To 50:115. Standard Accessories:- 1 Unit O2 Regulator- 1 Unit Air Regulator- 1 Unit Nitrous Regulator- O2, Air, Nitruos Fittings And Hose Clamps- 1 Unit Adult Anesthesia Circuit With 2l Bag- 1 Unit Pediatric Anesthesia Circuit With 1l Bag- 2 Units Power Adapter Avr: 2,000 Watts, 220-240v Ac, 60hertz, Servo-motor Controlled Type With Time Delay 8. 1 Unit Ent Treatment Unit Model Features: 1. Antibacterial Marble (under Cover) 2. Built-in Vision (inv-150c) Led 3. Built-in Scope Drawer 4. Auto Stop Warm Heater Composition: 1. Main Body - 1 Set 2. Illumination Light - 1 Set 3. Light Pole (sus) - 1 Set 4. Spray Gun (str3/cuv1) - 1 Set 5. Suction Pump - 1 Set 6. Air Compressor - 1 Set 7. Medicine Tray - 1 Set 8. Medicine Bottle - 1 Set 9. Waste Receptable Hanger - 1 Set 10. Cotton Ball Can Ø50x100 - 2 Each 11. Cauze Can With Cover Ø70x75 - 2 Set 12. Instrument Can Ø78x80 - 4 Each 13. Waste Receptacle Ø100x110 - 2 Each 14. Waste Receptacle Cover Ø100 - 1 Each 15. Suction Bottle With Cover 3000cc - 1 Set 16. Suction Bottle With Cover 300cc - 1 Set* With Additional Monitor And Furniture Avr: 2,000 Va 220-240v, 60hertz, Servo-motor Controlled Type With Time Delay 9. 1 Unit Ent Chair W/ Doctor Stool Features: 1. Extremely Low Noise By Moving 2. Up-down, Rise-lie And Horizontal Moving Available 3. Wide Range Of Operation Provides Ease Of Positioning 4. Ergonomic Design Offers Optimal Treatment Circumstances 5. Elegant Color Combination 6. Diversified Switch Selection By Examination Function 7. Multi-application With Ent Unit Available 8. Stainless Heas Rest 9. Recovering All Position By Pushing Reset Button Specification: 1. Power Source - Ac 220v, 50/60hz 2. Power Consumption - 400va, Max 3. Dimension - 670(w)x750(d)x1540(h), ±20mm 4. Net Weight - 98kg. Max 5. Base Diameter - Ø590, ±20mm 6. Movement (up/down) - 280mm, Max 7. Movemenr (rise/lie) - 90-180, ±20 8. Rotation - 340° Manual 9. Arm Rest - 360° Manual Avr: 1,500 Va 220-240v, 60hertz, Servo- Motor Controlled Type With Time Delay 10. 1 Unit Portable Xray Machine General Specifications Of The Unit Maneuverable Complete With Handrails And Positive Foot Or Hand Operated Breaks Electrically Grounded □ Motorized And Manually Driven □ Manually Driven Maximum Height Of 2 Meters At Transport Position Ground To Focus Distance - At Least 2 Meters High Tension Generator Generator: High Frequency Generator Settings: Kilovoltage Setting: Minimum Setting: 40 Kv And Maximum Setting: ≥ 125 Kv Maximum Tube Current: □ 100 Ma X-ray Tube Assembly Anode: Rotating Nominal Focal Spot Size: Small Focus: ≤ 0.8 Mm Large Focus: > 0.8 But ≤ 1.5 Mm Total Filtration: ≥ 2.5 Mm Al Equivalent Collimation System: Multi-leaf Manually Controlled With Field Lamp And Cross-hair Centering Rotation: Minimum Of ±45° Tube Head Rotation: Lateral Axis: □ 0 - 90° □ Not Applicable (for Units With Swiveling Out Tube Support Assembly) Longitudinal Axis: Minimum Of ±90° Tube Arm Movement: □ Lateral □ Horizontal □ Vertical Locking Mechanism: Electromagnetic/manual Control Unit Overload Protection Indicator: Visual/audible Technique Selector: □ Kilovoltage (kv) □ Milliamperage (ma) □ Time (sec Or Msec And/or Pulse) / Milliampere Second (mas) Display: □ Kilovoltage (kv) □ Milliamperage (ma) □ Time (sec Or Msec And/or Pulse) / Milliampere Second (mas) Exposure Switch: Dead-man Type Hand Switch With Cable (at Least 2 M) And Push Button Ready And X-ray Exposure Indicator: Audible And/or Visible Indicators For Motor Driven Units: Unit Is Fully Charged Unit Is Being Charged Unit Needs To Be Charged Shielded Storage Compartment: At Least Five (5) 14” X 17” Cassettes With Exposed And Unexposed Films Divider Accessories Radiation Protection: Device 1 Lead Rubber Apron Of At Least 0.25 Mm Pb Equivalence 1 Lead Rubber Thyroid Shield Of At Least 0.25 Mm Pb Equivalence 1 Pair Of Lead Rubber Gloves Of At Least 0.25 Mm Pb Equivalence 1 Set Of Lead Rubber Gonadal Shields With Minimum Of 0.5 Mm Pb Equivalence • Contact Shields For Male Adult, Female Adult, Infant Male And Infant Female Others 1 Pc Measuring Caliper, Sliding, Double Sided, Scaled In Cm, With Blunt Edges And Parallel Armhanger/s For Lead Apron/s Power Requirements 1 Phase , 220 Vac, 60hz As Applicable To The Power Supply Of The End-user Other Requirements: Documents Two Sets Of The Following: • Operation And Instruction Manuals • Service And Installation Manuals • Wiring And Schematic Diagrams • X-ray Tube Data Specifications • Parts List Terms Of Delivery: Thirty (30) Calendar Days Upon Receipt Of Notice To Proceed Terms Of Reference: Https://cavite.gov.ph/home/tor_2024-001/ Note: Bidder Shall Bid For The Entire Lot. Bid For Selected Lot Only Will Be Disqualified
Contact
Tender Id
3008210d-458d-3806-97cd-764a39b9ae50Tender No
10577044Tender Authority
Province Of Cavite ViewPurchaser Address
-Website
notices.philgeps.gov.ph