Hvac Tenders
Hvac Tenders
PUBLIC BUILDINGS SERVICE USA Tender
Civil And Construction...+1Others
United States
Details: Clarification 0001 (03 January 2025): Per The Combined Synopsis/solicitation Attachment, Questions Are Due No Later Than 5:00 Pm Local On 17 January 2025. This Posting Has Been Updated To Correct That Inconsistency.
amendment 0001 (20 December 2024): Update To Pre Proposal Conference Day And Time.
there Will Be A Virtual (via Google Meets) Pre-proposal Conference Held On 13 January 2025 At 3:00 Pm Edt. Interested Firms Wishing To Participate In The Pre-proposal Conference Are Required To Email Aaron Lay, Aaron.lay@gsa.gov, With The Names And Emails Of Each Participant From The Firm No Later Than Close Of Business 10 January 2025. Information Received During The Pre Proposal Conference Shall Not Constitute A Change In Requirements Or Scope Without A Written Amendment To This Solicitation.
original Post
solicitation Number: 47pa0325r0001 Notice Type: Combined Synopsis/solicitation Synopsis:
this Synopsis/solicitation Is A Request For Qualifications (rfq) For Zonal Architect And Engineering (ae) Indefinite Delivery Indefinite Quantity (idiq) Contracts, For A Period Of One Base Year Plus Up To Four One-year Option Periods Per Contract. Four Single Award Idiqs Will Be Made From This Solicitation For Ae Services. This Procurement Is Set-aside For Small Businesses. Interested Small Businesses May Submit An Offer For One Or More Zones.
classification Code: C – Architect And Engineering Services Naics Code: 541310
notice: Setaside For Small Businesses
the Deadline For Submitting Questions Is 5 P.m. Local Time On 17 January 2025.
special Programs Division (spd) Of The U.s. General Services Administration (gsa), Public Buildings Service (pbs), Has A Requirement For Professional Architectural And Engineering (ae) Services On An Indefinite Delivery/indefinite Quantity (idiq) Basis. Orders Placed By Spd Will Primarily Cover Requirements Of Client Agencies. Contracting Officers (cos) Within Pbs Will Be Authorized To Place Orders Against The Contracts Upon Receipt Of A Delegation Of Authority From The Spd Co.
four Single Award Idiq Contracts Will Include All Facilities Under The Jurisdiction, Custody And Control Of Gsa In The Entire United States (u.s.), Including All U.s. Territories. All Ae Services Will Be Provided When So Authorized By Execution Of Firm-fixed-price Task Orders. Individual Task Order Values Will Be Based On An Estimated Construction Cost At Award (ecca) Of Less Than Or Equal To The Prospectus Threshold (currently $3.6 Million). Note - This Value Can Be Exceeded If Agreed To By The Contractor.
this Requirement Is Solicited As A Total Small Business Set-aside. The Naics Code Is 541310 (architectural Services) And The Small Business Size Standard Is $12.5 Million. It Is Anticipated That Four Separate Contracts Will Be Awarded. The Firm-fixed-price Idiq Contracts Will Each Consist Of One Base Year And Up To Four, One-year Option Periods. Offerors May Submit A Proposal For Each Of The Zones They Are Interested In, But A Single Proposal For Multiple Zones Will Not Be Accepted. The Zonal Awards Shall Encompass The Following Primary Contract Areas.
zone A
1. New England
2. Northeast & Caribbean
3. Mid-atlantic
maine, Vermont, New Hampshire, Massachusetts, Connecticut, Rhode Island, New York, New Jersey, Pennsylvania, West Virginia, Virginia, Delaware, Maryland, Puerto Rico And U.s. Virgin Islands
zone B
4. Southeast Sunbelt
5. Great Lakes
6. Heartland
7. Greater Southwest
florida, Georgia, South Carolina, North Carolina, Kentucky, Tennessee, Mississippi, Alabama, Minnesota, Wisconsin, Michigan, Ohio, Indiana, Illinois, Nebraska, Iowa, Kansas, Missouri, New Mexico, Oklahoma, Arkansas, Louisiana, And Texas
zone C
8. Rocky Mountain
9. Pacific Rim
10. Northwest/arctic
alaska, Montana, North Dakota, South Dakota, Wyoming, Utah, Colorado, Nevada, Arizona, California, Washington, Oregon, Idaho, And Hawaii
zone D
11. National Capital
central Office
district Of Columbia And The Immediate Surrounding Area
on An Occasional Basis, Work May Also Include Locations In The Secondary Contract Area. The Secondary Contract Area For The Idiq Contract Covers The Entire United States (u.s.), Including All U.s. Territories, And Consists Of The Zones Comprising Other States And Territories That Are Not Covered As Part Of The Idiq Contract’s Primary Contract Area. The Secondary Contract Area May Be Awarded As A Primary Contract Area(s) Under Separate Contract(s) To Other Contractor(s). In Addition, The Secondary Contract Area Of This Contract May Also Be The Secondary Contract Area Under Other Contracts.
services May Be Provided Under This Contract Within The Secondary Contract Area If Ordered By The Government. However, The Contractor Is Not Obligated To Perform Work In The Secondary Contract Area And May Decline Such Orders By Notifying The Co Within 3 Workdays Of Receipt Of A Request For Proposal Or Order For Such Services. The Government Shall Have No Obligation To Order Services To Be Performed Under This Contract Within The Secondary Contract Area, And Its Failure To Order Any Such Services Shall Not Breach Or Otherwise Violate The Contract.
small Business Set-asides. When Forming A Formal Joint Venture Or Partnership In Response To A Small Business Set-aside, All Team Members Must Meet The Socioeconomic Status For The Set-aside. For All Contractor Team Arrangements (ctas) Submitted In Accordance With Far Subpart 9.6, The Limitations On Subcontracting (far 52.219-14) Apply, (i.e., The Small Business Team Members Must Perform At Least 50% Of The Value Of The Work To Be Completed).
the Maximum Ordering Limitation (mol) For Each Contract Across All Potential Contract Years Is $50 Million Dollars. There Will Be A $1,000 Guaranteed Minimum For The First Year Of Each Idiq.
the Contracts Will Be Solicited And Awarded Pursuant To The Brooks Act, Federal Acquisition Regulation (far) Subpart 36.6, And General Services Acquisition Manual (gsam) Subpart 536.6.
scope
work Under Typical Task Orders Issued Under Each Idiq Contract Will Include, But Will Not Be Limited To: The Study Of Architectural And/or Engineering Problems/existing Conditions (known As Extra Field Investigation – Efi); Recommendation Of Solutions And Anticipated Costs For The Solutions; Engineering Studies, Retro-commissioning, Pre-design Phase Services, Preparation Of Schematic Designs (sds), Design Development Drawings (dds), Design Intent Drawings (dids), Construction Documents (cds) And Specifications For Various Projects; Drafting Design-build Statements Of Work (sows); And Monitoring Of Construction Activities In The Form Of Post Contract Construction Services (pccs). Requirements For Typical Task Order Sows Will Also Involve Engineering And Architectural Services For Reports, Investigations, Subsoil Investigations, Site Surveys And Analysis, Site Utility Studies, Geotechnical Engineering Services, Environmental Studies, Energy Studies/audits, Materials Selection, And Design.
firms Shall Be Capable Of Performing The Work With In-house Staff And/or In Conjunction With Consultants, Partnerships, And/or Joint Ventures.all Ae Services Will Be Provided When So Authorized By Execution Of Firm-fixed-price Task Orders.
the Work Will Require Various Primary Disciplines, Including:
architectural, Civil, Structural, Mechanical (hvac And Plumbing), Electrical, Fire Protection
cost Estimator, Environmental Engineer, Historic Preservationist, And Landscape Architect.
secondary/supplemental Disciplines Which May Be Required On An As-needed Basis Include:
marine Engineer, Geotechnical Engineer, Registered Land Surveyor, And Other Disciplines As Requested By Gsa.
at A Minimum, Firms Shall Have A Team Comprised Of The Following Disciplines – Architects, Electrical Engineers, Mechanical Engineers, Fire Protection Engineers, Civil Engineers, Structural Engineers, Environmental Engineers, Cost Estimators, And Historical Preservationists And Landscape Architects.
pre Proposal Conference:
there Will Be A Virtual (via Google Meets) Pre-proposal Conference Held On 13 January 2025 At 3:00 Pm Edt. Interested Firms Wishing To Participate In The Pre-proposal Conference Are Required To Email Aaron Lay, Aaron.lay@gsa.gov, With The Names And Emails Of Each Participant From The Firm No Later Than Close Of Business 10 January 2025. Information Received During The Pre Proposal Conference Shall Not Constitute A Change In Requirements Or Scope Without A Written Amendment To This Solicitation.
information To Interested Small Business
register In The System For Award Management (sam) Database (www.sam.gov).
Closing Date21 Jan 2025
Tender AmountRefer Documents
DEPT OF THE ARMY USA Tender
Civil And Construction...+1Civil Works Others
United States
Details: Date Soliciation Documents Available (approx.): 14 January 2025
this Project Is Advertised On An Unrestricted Basis.
this Solicitation Is A “best Value”, Two-phase Source Selection. In Phase One, Offerors Will Compete For The Opportunity To Submit Proposals For Phase Two. In Phase One, An Offeror Must Submit Certain Specified Information Regarding Its Company’s Past Performance And Technical Approach. Price Is Not A Submission Requirement In Phase One. Based On The Results Of Phase One Evaluations, The Government Will Select Two Or More Of The Most Highly Rated Offerors To Participate In Phase Two. However, The Government Reserves The Right To Reject Any And/all Offers. In Phase Two, Offerors Will Compete To Determine Which Offerors Will Be Awarded An Indefinite Delivery/indefinite Quantity (idiq) Contract And Be Included In The Matoc Pool. Price Proposals Will Be Submitted In Phase Two And Will Consist Of Two Bid Schedules: Bid Schedule No. 1 (rates) And Bid Schedule No.2 (seed Project Price). Following Phase Two Evaluations, The Government Intends To Award Two Or More Matocs And To Award The Seed Project (bid Schedule No. 2) To One Of The Awardees. However, The Government, At Its Discretion, Is Not Obligated To Award Any Matocs Or The Seed Project As A Result Of The Evaluations.
description Of Work (physical Characteristics)
the Government Intends To Award Multiple Contracts Pursuant To This Solicitation. These Contracts Shall Be Indefinite Delivery/ Indefinite Quantity (idiq) Multiple Award Task Order Contracts (matoc) With Design Build Capabilities To Support U.s. Army Corps Of Engineers, Mobile District, Military Construction And Support For Others Program For Construction Requirements In Central America. This Requirement Is Being Handled By The U.s. Army Corps Of Engineers, Mobile District; Mobile, Alabama.
the Term Of The Contract Is Limited To A Five Year Ordering Period. The Guaranteed Minimum For The Contract Is $1,000. The Total Dollar Capacity For The Contract Is $99 Million Over Five Years.
contractors Shall Complete All Work Under Their Contract In Accordance With Schedules That Are Established In Each Task Order. Work Will Vary From Site To Site, Or Location, And Will Require Extensive Knowledge Of Construction And Renovation Projects. Submittal Dates Will Be Included In The Individual Task Orders. These Dates Identify When Information Is Due To The Issuing Government Office And Other Addresses Identified In The Individual Task Orders. The Types And Numbers Of Submittals And Dates And Places For Review Meetings Shall Be Established By Each Task Order Under This Contract. Defense Base Act (dba) Insurance Will Be Required For All The Task Orders.
the Government Anticipates That Task Orders Will Be Awarded On A Firm Fixed-price Basis.
objective. This Contract Will Require Contractors To Provide All Plant, Labor, Equipment And Materials Necessary To Perform Design, Construction, Incidental Demolition, Upgrade And Repair Of Facilities And Structures. Work Will Typically Include Vertical And Horizontal Construction, Site Work, Geotechnical Surveys, Landscaping, Surveying, Mapping, Mechanical And Electrical Work For Blast Resistant, Fortified Structures; Rigid And Flexible Paving For Roads, Airfields And Helipads; Parking Lots; Riverine And Marine Construction Of Floating Docks, Piers, And Barges; Dredging; Construction Of Remote And Temporary Camps, Firing Ranges, Rappel Towers, Shoot Houses, Fuel Systems, Ammunition Storage, Food Storage, Interior And Exterior Utilities To Include Water And Sewage Treatment, Water Wells, Communications, Electrical Power (to Include Generators And Solar And Wind Power), Security (to Include Field Fortifications, Wire Obstacles, Bunkers, Watch Towers And Security Fencing And Hardening Of Existing Facilities) And Safety Of Facilities. Facilities And Structures May Include Administrative Buildings, Barracks, Warehouses, Hangars, Schools, Motor Pools, Etc. The Work May Involve Replacement In Kind, Repairs, Upgrades And Modification Work And/or New Construction. It Also May Include Incidental Design And Testing, And Survey And Abatement For Lead Based Paint (lbp) And Asbestos Containing Materials (acm). Facility Repairs, Upgrades And Construction Shall Conform To The Requirements Of The Technical Criteria Listed In The Task Order. Task Orders May Require The Application Of U.s. Building Codes; International Building Code (ibc); National Electric Code (nec); Structural And Heating, Ventilation And Air Conditioning (hvac) Codes; And U.s. Department Of Defense Criteria That Include, But Are Not Limited To, Unified Facility Criteria (ufc) And Anti-terrorist And Force Protection (aftp) Requirements As Well As Any Host Nation Requirements That May Be Stricter Than Those Listed Above. In Addition, Construction Materials, Including, But Not Limited To Locally Available Aggregates, Cements, Reinforcing Steel, Structural Lumber, Block Masonry Products, Conduit And Electrical Devices, Pipe And Plumbing Fixtures, May Be Purchased Under This Contract. Some Construction May Occur At Remote Locations And Close Coordination Will Be Required With Both The Us Army Corps Of Engineers And Host Nation Military And Civilian Authorities Throughout The Life Of The Projects. Projects On Host Nation Military Installations Will Require That Employees Be Vetted For Security By Host Nation Military Authorities. The Work Described Herein Shall Be Accomplished Through The Implementation Of Task Orders Issued Under The Terms Of This Solicitation.
seed Project: To Be Identified In Phase Two
the North American Industry Classification System (naics) Code For This Project Is 236220.
estimated Cost Range Project: $25,000,000 To $100,000,000
offers Covering The Project Restricted To Small Business Yes_ __ No_ X _
*restricted To 8(a) Competitive For Region Iv Yes___ No_x_
Subcontracting Plan Required Yes_ __ No_ X__
field Office: Central America Resident Office
Poc: Ivan Olivieri, 251-694-4027
project Manager: Julie Walton, 251-694-4633
project Engineer: Steven Mcdavid, 251-690-2621
specification Engineer: Melody Little, 251-690-2916
contract Specialist: Terri Adams, 251-441-6500
note No. 1: All Prospective Contractors And Their Subcontractors And Suppliers Must Be Registered In The System For Award Management (sam.gov) Before They Will Be Allowed To Download Solicitation Information. Contractors Must Be Registered In The System For Award Management (sam) At Https://sam.gov/content/home Prior To Award Of This Contract. Solicitation Documents, Plans And Specifications Will Only Be Available Via The Procurement Integrated Enterprise Environment (piee) Website Https://piee.eb.mil See Attachments Piee Solicitation Module Vendor Access Instructions And Sop Piee Proposal Manager Offeror For Instructions On Getting Access To The Piee Solicitation Module And Submitting Your Proposal. Registration For Plans And Specifications Should Be Made Via The Procurement Integrated Enterprise Environment (piee) Website Https://piee.eb.mil. If You Are Not Registered, The United States Government Is Not Responsible For Providing You With Notifications Of Any Changes To This Solicitation. The Solicitation Will Be Available Only As A Direct Download. This Solicitation Will Not Be Issued On Cd-rom. Neither Telephonic, Mailed, Nor Fax Requests Will Be Accepted. Registration Should Be Completed One (1) Week Prior To The Issue Date. It Is Therefore The Contractor’s Responsibility To Monitor The Website Daily For The Solicitation To Be Posted, And For Any Posted Changes Or Amendments To This Solicitation. The Plans And Specifications And All Notifications Of Changes To This Solicitation Shall Only Be Made Through This Posting And Modifications Hereto. Plans And Specifications Will Not Be Provided In A Printed-paper Format; However, The Government Reserves The Right To Revert To Paper Medium When It Is Determined To Be In The Government's Best Interest. Note: This Solicitation Is In .pdf Format And Requires Adobe Acrobat Reader. Adobe Acrobat Reader May Be Downloaded Free Of Charge At Http://www.adobe.com/products/reader.
note No. 2: All Bid Forms, Bid Bonds, And Other Normal Documents Required For The Bid Submittal, Including Amendments To The Bid Submittal, Shall Be Electronic Format With The Proposal.
note No. 3: All Advertisements Of Mobile District Projects Will Be Through The Procurement Integrated Enterprise Environment (piee) Website Https://piee.eb.mil. Detailed Information On This And Other Mobile District Projects (ordering Solicitations, Points Of Contact, Synopsis Of Work, Etc.) Are Available On The Internet At The Procurement Integrated Enterprise Environment (piee) Website Https://piee.eb.mil.
address Questions Concerning Downloading Of Plans/specifications To The Contract Specialist Indicated Above.
note No. 4: A Contractor Site Visit Will Be Conducted With Those Offerors Advancing To Phase Two. Phase Two Offerors Will Be Notified Via Amendment, As To When And Where The Site Visit Will Be Conducted.
note No. 5: The Request For Information (rfi) Process For Bidder Inquiries During The Advertisement Period Will Be Through The Projnet Internet-based System, And Specifics Will Be Contained In The Rfp Solicitation Package Available Exclusively From The Procurement Integrated Enterprise Environment (piee) Website Https://piee.eb.mil. Other Forms Of Communicating Rfis To The Government Will Not Be Honored. The Government Will Try To Respond To All Questions. However, Responses May Not Be Furnished To All Questions And Particularly Those Received Late In The Advertisement Period (0-10 Days Prior To Bid Opening.)
Closing Date18 Feb 2025
Tender AmountRefer Documents
DEPT OF THE ARMY USA Tender
Civil And Construction...+2Others, Civil Works Others
United States
Details: As Of 30 December 2024, The Following Amendments Have Been Made:1) The Size Standard Statement Has Been Removed And 2) The Project Manager (pm) Has Been Updated To Include R.a. Required.
1. Contract Information:
these Contracts Are Procured As A Small Business Set-aside. The Naics Code’s Are 541330 And 541310.
the Number One, Two And Three Ranked Small Business Firms Will Be Selected For Negotiations Based On Demonstrated Competence And Qualifications For The Required Work. The Length Of Each Indefinite Delivery Contract (idc) Is A Maximum Of 60 Months And Will Not Include Optional Time Periods. Three (3) Idc’s Will Share $49.9m Total Capacity Of The Matoc. Task Orders Will Be Issued By Negotiated Firm-fixed-price Task Orders To The Most Technically Qualified Offeror In Response To The Task Order Requirement Notification (torn) And Will Be Issued Under The Terms And Conditions Of This Matoc. The Government Guarantees A Minimum Value Of $4,000 Seed Task Order For Each Individual Idc. Labor Rates For Each Discipline, Overhead Rates, And Escalation Factors For Each 1 Year Time Period Will Be Negotiated For Each Basic Idc And Profit Will Be Negotiated For Each Task Order Not For Each Basic Idc.
work Distribution Between Idcs: Task Orders (to) Will Be Distributed According To The Experience And Qualifications Of The A-e Firms. The Specific Contractor Chosen For A To Will Be Selected Based On Factors Such As Technical Expertise, Demonstrated Performance, Specific Ability, To Size And Complexity, And Contractor Availability To Complete The To In The Time Required. We Are Going To Have The A-e Firms To Compete Amongst The Highly Qualified Selectees For This Contract. Above All, It Is The Intent Of The New York District To Not Have A “hollow” Contract.
three (3) Indefinite Delivery Contracts Will Be Negotiated That Includes Level Of Efforts, Labor Rates For Each Discipline And Overhead Rates For The Contract Period. Profit Will Be Negotiated In Each Task Order Not In The Basic Contract.
the Selected Small Business A-e Firms Will Need To Demonstrate Capability To Perform At Least 51% Of The Contract Work Listed Below In Accordance With Ep 715-1, Chapter 3-8 C Which Can Be Found At Http//www.usace.army.mil/publications/eng.pamphlets/ep715-1-7
in Particular, In Order To Be Awarded A Small Business Contract The Concern Will Perform At Least 51 Percent Of The Cost Of The Contract Incurred From Personnel With Its Own Employees.
“any Subcontractor And Outside Associates Or Consultants Required By The Contractor (prime A-e Firm) In Connection With The Services Covered By The Contract Will Limit To Individuals Or Firms That Were Specifically Identified And Agreed To During Negotiations The Contractor Shall Obtain The Contracting Officer’s Written Consent Before Making Substitutions For These Subcontractors, Associates Or Consultants”.
if A Substitution Is Necessitated By Illness, Death, Or Termination Of Employment For Whatever Reason, The Selected A-e Firm Shall Notify The Contracting Officer In Writing Within 15 Calendar Days After The Concurrences Of Any Of These Events And Provide The Following Information To The Contracting Officer:
required Information For Substitution Necessitated By Illness, Death, Or Termination Of Employment For Whatever Reason: The Contractor Shall Provide A Detailed Explanation Of The Circumstances Necessitating The Proposed Substitution, Complete Resumes For The New Proposed Substitutes, And Any Additional Information Requested By The Contracting Officer. Proposed Substitutes Should Have Comparable Qualifications Or Better Qualifications To Those Of The Persons Being Replaced. The Contracting Officer Will Notify The Contractor Within 15 Calendar Days After Receipt Of All Required Information Of The Decision On Substitutions.
approximate Award Date: June 2025
the Wages And Benefits Of Services Employees (see Far 22.10) Performing Under This Contract Must Be At Least Equal To Those Determined By The Department Of Labor Under The Service Contract Act, As Determined Relative To The Employee’s Office Location (not Of The Location Of The Work). To Be Eligible For A Contract Award, The Firm Must Be Registered In The Dod Central Contractor Registration (ccr). Registered Via The Ccr Internet Site At Http://www.ccr.gov Or By Contacting The Dod Electronic Commerce Information Center At 1-800-334-3414.
2. Project Information:
a-e Services May Include But Not Be Limited To The Following:
general Architect Engineering Services To Include Support Of The Milcon Programs, Sustainment, Restoration And Modernization (srm) Program, Iis Program And Other Non-military Construction Programs Within Nan/nad Boundaries.
architect Engineering (a-e) Services For Smaller Scale Projects Typically With A Construction Cost Of Approximately $10m Or Less To Include The Following:
construction Of New And Renovation/upgrade Of Multiple Hangar/buildings, Maintenance, Training Facilities (hands-on/simulators), Aviation Facilities, Runways And Taxiways, Aircraft Fueling Facilities/distribution, Industrial Facilities, Vehicle Maintenance Facilities, Research & Design Facilities (armament, Munitions And Communications), Munitions And Storage Facilities, Dining Facilities, Academic Labs, Barracks/dormitories, Academic Facilities, Administrative Office Buildings
antarctic/cold Region Construction.
whole And/or Partial Building Renovations Which Address Interior Re-configuration, Life/safety, Energy Conservation, And Utility Systems.
architectural Alterations Which Address New Space Requirements, Programmed Functions Such As: Maintenance, Training Facilities, Storage, Administrative Spaces, And Squad/ops.
new Building Exterior And Envelope (cold Region) Shall Follow The Architectural Compatibility Plan Defined At The Base Inclusive Of, Structural Roof Systems, Insulation And Waterproofing, Windows, And Atfp.
mechanical/electrical/plumbing (mep): Fire Suppression And Water Supply Systems, Fire Alarm And Mass Notification System, Cybersecurity, Fire Detection/protection/monitoring And Controls, Heating And Ventilation Systems, Plumbing Systems, Electrical Systems, Telecommunication And Cabling Systems, Closed Circuit Television (cctv), Alarm And Card Access Systems, And Public Address Systems.
topographic Surveys, Geological Surveys, Geotechnical Investigations, Environmental Investigations, Master Planning Studies, Value Engineering Studies, Field Investigation Studies, Construction Support Services.
asbestos And Lead Abatement Services Related To Building Renovation Or Demolition.
perform/conduct Design Charrettes Including Eco-charrettes
prepare Studies (to Include Building, Energy, Life-cycle Studies)
prepare Parametric Designs, To Include Development Of Dd Form 1391 Preparation.
site & Infrastructure/seismic Design In Accordance With The Ufc’s
development Of Design Criteria And Basis Of Design
design Work Analysis And Technical Specifications
nepa Documentation And Coordination
historic Architecture And Section 106 Consultation
preparation Of Permit Applications.
preparation Of Design/build Documents
preparation Of Arctic Foundation Designs, Building Air Tightness And Hvac Performance For Cold/arctic Regions.
preparation Of Designs Including Hemp And Scif Areas.
preparation Final Design Construction Documents
antiterrorism/force Protection Design In Accordance With Applicable Ufc’s
sustainable Design/gbi/net Zero Strategy Development
cost Estimating Using The Latest Version Mii [m2] Software.
value Engineering Studies And Cost Schedule Risk Analysis (csra).
preparation Of Deliverables In Building Information Modeling (bim) Format.
drawings In Accordance With The Architectural/engineering/construction (a/e/c) Computer-aided Standard Version (cadd)
demonstrated Construction Phase Services:
design During Construction
preparation Of Operation And Maintenance Manuals
providing Technical Assistance – Responding To Requests For Information (rfis)
design Build Conformance Reviews
shop Drawing Review – Review Of Shop Drawings And Submittals
conduct Site Visits
commissioning/enhanced Commissioning; Fit-up Design Support
project Start-up – Coordinate With Contractors To Start Up And Conduct Performance Tests Of The Constructed Project.
projects Designed Under These Contracts May Require Designers To Obtain Security Clearances As Well As Having Physical Security Measures In Place Before A Firm Can Do The Work. Security Clearances Are Not Required At The Time Of Selection Or Award Of A Contract.
3. Selection Criteria:
primary Selection Criteria:
the Selection Criteria Are Listed Below In Descending Order Of Importance (first By Major Criterion And Then By Each Sub-criterion).
criteria A Through E Are Primary Selection Criteria.
criteria F Through H Are Secondary Selection Criteria And Will Only Be Used As Tiebreakers Among Technically Equal Firms.
the Firm Is Required To Have The Following Specific Design Capabilities:
a. Specialized Experience And Technical Competence In:
submit At Least Five (5) Example Projects In Sf-330 Section F That Demonstrates Experience With The Following: Building (whole And/or Partial) Renovation Design That Includes At Least Five (5) Of The Following Design Elements As A Substantial Part Of The Design (replacement Of Architectural Elements, Interior Re-configuration, Building Seismic Upgrade, Anti-terrorism/force Protection Upgrades, Mechanical Systems, Hvac Systems, Electrical Upgrades, Fire Protection/detection Systems, Exterior Envelope Upgrades Including Roof, Windows And Walls, Asbestos And Lead Abatement.). The Projects Shall Demonstrate The A/e’s Ability To Execute Design Charrettes, Concept Designs, Final Designs And Prepare Final Construction Bid Documents. Projects May Include The Following Facility Types: Academic Facilities, Administrative Facilities, Barracks, Research And Development Facilities, Manufacturing Facilities, Hangers, Maintenance Facilities And Training Facilities. The Ae Shall Identify The Month And Year The 100% Final Design Was Completed. The Ae Shall Identify The Month And Year The Construction Was Completed. Projects Shall Have A Construction Cost Of Approximately $10m. Construction Of The Projects Must Be Completed After January 2017. Projects Completed Before January 2017 Will Not Be Considered.
submit At Least Three (3) Example Projects In Sf-330 Section F That Demonstrates Experience With The Following: Infrastructure Type Design That Includes At Least Three (3) Of The Following Design Elements As A Substantial Part Of The Design. The Ae Shall Demonstrate Experience In Planning, Designing And Preparing 100% Construction Bid Documents. Projects May Include The Following Project Types (each Example Project Shall Represent A Different Project Type): Road/parking Replacement/repairs, Utility Infrastructure Replacement/repairs, Utility Central Plant Upgrades/repairs, And Retaining Wall Upgrades/repairs. The Ae Shall Identify The Month And Year The 100% Final Design Was Completed. The Ae Shall Identify The Month And Year The Construction Was Completed. Projects Shall Have A Construction Cost Of At Least $5m. Construction Of The Projects Must Be Completed After January 2017. Projects Completed Before January 2017 Will Not Be Considered.
submit At Least Two (2) Example Projects In Sf-330 Section F That Demonstrates Experience With The Following: Design Of New Facilities. The Ae Shall Demonstrate Experience In Sustainable Design Using An Integrated Design Approach And Emphasizing Environmental Stewardship, With Experience In Energy And Water Conservation And Efficiency; And Employing The Leed Evaluation And Certification Methods. The Projects Shall Demonstrate The A/e’s Ability To Execute Design Charrettes, Concept Designs, Final Designs And Prepare Final Construction Bid Documents. Projects May Include The Following Facility Types: Academic Facilities, Administrative Facilities, Barracks, Research And Development Facilities, Manufacturing Facilities, Hangers, Maintenance Facilities And Training Facilities And Training Facilities. The Ae Shall Identify The Month And Year The 100% Final Design Was Completed. The Ae Shall Identify The Month And Year The Construction Was Completed. Projects Shall Have A Construction Cost Of Approximately $10m. Construction Of The Projects Must Be Completed After January 2017. Projects Completed Before January 2017 Will Not Be Considered.
the Above Requested Projects Shall Also Demonstrate The A/e’s Abilities With All Of The Following:
- Planning And Scheduling Management Of Fast Track Designs,
- Working On Military Installation Projects,
- Prepare Cost Estimates Using Mii And Paces, (the Cost Estimator And/or The Subcontractor Should Demonstrate Familiarity With The Changing Dynamics Of The Current Construction Market In The Tri-state New York Area With Particular Emphasis On The Southern New Jersey),
- Preparing Drawings In Autocad And Autocad Revit,
- Experience In The Ability To Provide A Qa/qc Plan Indicating How The Prime Plans To Manage Their Team To Ensure That Quality Products Are Prepared. Demonstrate Ability To Produce Quality Designs. Evaluation Will Be Based On The Firm's Design Quality Management Plan (dqmp) And Will Consider The Management Approach, Coordination Of Disciplines, Management Of Subcontractors And Quality Control Procedures.
on All Ten (10) Example Projects, The Government May Consider The Following Strengths For Evaluation Purposes:
projects Demonstrating Experience Working At Military Installations Within Nan Boundaries.
projects Demonstrating Experience Working With Nydec And Njdep In Obtaining Environmental Permits.
projects Demonstrating Experience With Sustainable Design And Achieving Leed Silver Or Better.
projects Demonstrating Experience Working Mcaces Paces And Pax/dd1391.
projects Demonstrating Experience With Fast-tracked Designs.
projects Demonstrating Experience Utilizing A Design Quality Control Plan
projects Demonstrating Experience In Permitting, Real Estate Actions, Nepa Documentation, And Other Agency Coordination Tasks.
b. Qualified Registered Professional Personnel In The Following Key Disciplines:
project Manager (p.e. Or R.a. Required)
quality Assurance Manager (p.e. Or R.a. Required)
architecture (r.a. Required)
structural Engineering (p.e. Required)
civil Engineering (p.e. Required)
mechanical Engineering (p.e. Required)
electrical Engineering (p.e. Required)
fire Protection Engineering (p.e. Required)
landscape Architect (r.la. Required)
cost Engineering (p.e. Required. Those With Ccp/cpe Certification Will Be Considered A Strength)
geotechnical Engineering (p.e. Required)
certified Industrial Hygienist (cih Required)
licensed Interior Designer (ncid Required)
land Surveyor (p.l.s. Required)
anti-terrorism/force Protection Specialist (p.e. Required)
blast/explosives Safety Engineering (p.e. Required)
industrial Engineering (p.e. Required)
industrial/process Engineer (p.e. Required)
lean-six Sigma Professional
historic Preservationist
environmental Engineering (p.e. Required)
lead Commissioning Specialist (p.e And At Least One Of The Following: A Nebb Qualified Systems Commissioning Administrator (sca); Acg Certified Commissioning Authority (cxa); Icb/tabb Certified Commissioning Supervisor; Bca Certified Commissioning Professional (ccp); Aee Certified Building Commissioning Professional (cbcp); University Of Wisconsin-madison Qualified Commissioning Process Provider (qcxp); Ashrae Commissioning Process Management Professional (cpmp))
certified Value Specialist (cvs Required)
telecommunications Engineering (rccd Required)
master Planner (p.e. Or R.a. Required)
the Evaluations Will Consider Education, Training, Registration, Voluntary Certificates, Overall And Relevant Experience, And Longevity With The Firm Using Information From Section E Of The Sf 330. The Sf 330 Includes A Matrix In Section G Showing Experience Of The Proposed Lead Designers On The Projects Listed In Section F Of The Sf 330.
senior Project Personnel For Each Discipline Are Required To Be Licensed And/or Registered.
additional Disciplines May Be Submitted As Required By The Ae For This Type/size Project And Will Be Evaluated As The Above.
fire Protection Engineering: The Services And Qualifications Of Fire Protection Engineers Are Shown In Section 1.6 Of Ufc 3-600-01, And Are Reiterated Here: A Qualified Fire Protection Engineer Shall Be An Integral Part Of The Design As It Relates To Fire Protection. This Includes, But Is Not Limited To, Building Code Analysis, Life Safety Code Analysis, Design Of Automatic Detection And Suppression Systems, Water Supply Analysis, And A Multi-discipline Review Of The Entire Project. For The Purposes Of Meeting This Requirement A Qualified Fire Protection Engineer Is Defined As An Individual Meeting One Of The Following Conditions:
i.) A Registered Professional Engineer (p.e.) Having A Bachelor Of Science Or Master Of Science Degree In Fire Protection Engineering, From An Accredited University Engineering Program, Plus A Minimum Of 5 Years’ Work Experience In Fire Protection Engineering.
ii.) A Registered Professional Engineer (p.e.) Who Has Passed The National Council Of Examiners For Engineering And Surveys (ncees) Fire Protection Engineering Written
examination.
iii.) A Registered Professional Engineer (p.e.) In A Related Engineering Discipline With A Minimum Of 5 Years’ Experience, Dedicated To Fire Protection Engineering That Can Be Verified With Documentation.
the Ae And Their Subconsultants Must Be A U.s. Company(ies). The Ae’s Team Must Use Only U.s. Citizens Or U.s. Persons (an Individual Who Has Been Lawfully Admitted For Permanent Residence As Defined In 8 U.s.c. § 1101(a)(20) Or Who Is A Protected Individual As Defined By Title 8 U.s.c. § 1324b (a)(3)). The A-e’s Team Must Be Able To Obtain Visitor Registration Documents/passes To Access Any Military Base And/or Federal Facility Under This Contract.
c. Past Performance On Dod And Other Contracts With Respect To Cost Control, Quality Of Work And Compliance With Performance Schedules, As Determined From References, Other Sources And Cpars. Letters Of Recommendation From Customers Addressing Your Firm’s Cost Control, Quality Of Work And Schedule Compliance Capabilities May Be Included In Section H Of The Sf 330. Letters Should Be For Projects Of A Similar Nature And Shall Be No Older Than Three Years To Be Considered.
d. Capacity To Initiate Work And Complete Within The Time Parameters Of The Project. The Evaluation Will Consider The Availability Of An Adequate Number Of Personnel In All Key Disciplines. The Evaluation Will Review Part Ii Of The Sf330 To Evaluate The Overall Capacity Of The Team. Include A Part Ii Form Of The Sf 330 For Each Firm And Each Office Of Each Firm That Is Part Of The Proposed Team.
e. Knowledge Of The Locality In The General Geographical Area Of Ny District Boundaries. The Evaluators Will Review Projects Identified In Section F, The Specific Experience Of The Listed Key Discipline In Section E And Additional Information In Section H In Order Of Preference.
secondary Selection Criteria:
f. Geographic Proximity In Relation To Ny District Boundaries.
g. Volume Of Work Previously Awarded To The Firm By The Department Of Defense, With The Object Of Effecting An Equitable Distribution Among Qualified A/e Firms, Including Small Business, Veteran-owned Small Business, Service-disabled Small Business, Hubzone Small Business, Small Disadvantaged Small Business And Woman-owned Small Business And Minority Institutions And Firms That Have Not Had Prior Dod Contracts.
4. Submission Requirements:
interested Prime Firms Having The Capabilities To Perform These Services Must Submit Their Sf330 To Stephen Dibari By Email Stephen.dibari@usace.army.mil Maximum File Size Is 25 Mb If Overall Sf330 Is Larger Than 25 Mb, Please Break Up The File Into Smaller Separate Files.
no Hard Copies Of Sf-330’s Will Be Required. Do Not Mail Sf-330’s (cd Or Hard Copies) To The Contract Specialist Nor To Stephen Dibari At 26 Federal Plaza. Doing So, Will Delay The Ae Selection/award Process.
the Sf 330 Can Be Found By Searching For Sf330 On The Following Gsa Website: Https://www.gsa.gov/forms
the Forms Can Be Downloaded In A .pdf File Type. Total Submittal Page Limitation Is 85 Pages. Section E Is Limited To 50 Pages. Section F Is Limited To 10 Pages (1 Page Per Project). Each Page Shall Be Numbered. Section Dividers, Front And Back Covers, Cover Letter And Part Ii Of The Sf 330 Don’t Count Towards Overall Page Limit. Tabloid Size Paper 11” X 17” Pages For Organizational Chart Or Other Graphics Will Count As One Page. Submittals Not Following These Instructions, May Not Be Evaluated By The Board.
supplemental Information On The Sf 330 Is Posted On The Ny District Usace Website: Https://www.nan.usace.army.mil/business-with-us/engineering-division/
submittals Will Not Be Accepted After 2:00 Pm On The Response Date Shown In The Advertisement In The Https://sam.gov/. If The Response Date Falls On A Saturday, Sunday, Or A Federal Holiday, The Response Date Will Move To The Next Business Day.
for Questions Regarding This Contract, Contact Stephen.dibari@usace.army.mil
if A Pre-selection Meeting Is Required, Notifications Will Not Be Sent After Approval Of The Pre-selection. Notification Of All Firms Will Be Made Within Ten (10) Calendar Days After Selection Approval. In Addition To The Two (2) Items Listed Above, The Remaining Info On Release Of Information On Firm Selection Shall Be In Accordance With Uai Subpart 5.4 (usace Acquisition Instructions).
interviews (discussions) Will Be Held With All The Most Highly Qualified Firms As Required By Far 36.602-3(c). All Firms Will Be Interviewed By The Same Method (telephone, Video Teleconference Or In Person). Firms Will Be Given Sufficient Advance Notice To Allow Representatives To Participate In The Interviews Or Presentations. All Firms Will Be Asked Similar Questions. The Questions Will Be Related To The Announced Selection Criteria Including But Not Limited To, Their Experience, Capabilities, Capacity, Organization, Management, Quality Control Procedures And Approach For This Project.
firms Must Be Registered In The Following: Https://www.sam.gov/
naics Code’s Are 541330 And 541310.
interviews (discussions) Will Be Held With All The Most Highly Qualified Firms As Required By Far 36.602-3(c). All Firms Will Be Interviewed By The Same Method (telephone, Video Teleconference Or In Person). Firms Will Be Given Sufficient Advance Notice To Allow Representatives To Participate In The Interviews Or Presentations. All Firms Will Be Asked Similar Questions. The Questions Will Be Related To The Announced Selection Criteria Including But Not Limited To, Their Experience, Capabilities, Capacity, Organization, Management, Quality Control Procedures And Approach For This Project.
Closing Date27 Jan 2025
Tender AmountRefer Documents
VETERANS AFFAIRS, DEPARTMENT OF USA Tender
Civil And Construction...+1Others
United States
Details: Presolicitation Notice
presolicitation Notice
presolicitation Notice
*=required Field
presolicitation Notice
this Pre-solicitation Notice Is Not A Request For Proposal. All Information Needed To Submit Sf330 Documents Are Contained Herein. No Additional Solicitation Package Or Technical Information Will Be Issued.
project: 534-23-106 Ae Upgrade Mechanical Systems Phase 2
work Location: Ralph H. Johnson Health Care System, Charleston, Sc
estimated/target Completion Period: 360 Calendar Days After Award.
construction Magnitude: Between $5,000,000 And $10,000,000
naics: 541310 Architectural Services
small Business Standard: $12.5 Million
set-aside: 100% Service-disabled Veteran-owned Small Business (sdvosb)
site Visits Will Not Be Arranged During This Phase.
the Anticipated Award Date Of The Proposed A-e Contract Is On Or Before September 01, 2025.
sf 330 Date Of Receipt/due Date: Interested Firms Having The Capabilities To Perform This Work Must Submit One (1) Electronic Sf330 And Attachments If Any, No Later Than
(nlt) 10:00 Am (est) February 5, 2025.
project Overview:
provide Professional Architect/engineer (a/e) Services Necessary For A Complete Design To Replace The Main Laboratories Air Handling Unit, Correct Hvac And Mechanical Systems Deficiencies, And Provide Compliant Temperature Control And Air Change Requirements By Areas As Defined In The Limits Of Work. Additional Scope Includes Assessment And Replacement Of Isolation Exhaust Systems And Steam-to-hot Water Heat Exchangers And Associated Pumps Located In Penthouse, Specialty Clinics, And Eye Specialty Clinic. The Project Will Include Temporary Hvac Considerations And Phasing To Enable Continued Operations.
sdvosb Set-aside:
this Requirement Is A 100% Set-aside For Service-disabled Veteran-owned Small Businesses Under The Authority Of 38 U.s.c. 8127(d). To Be Eligible For Award The Sdvosb You Must Be Considered Small Under The Relevant Naics Code. Sdvosb Contractors Must Be Verified And Viewable In Small Business Administration Veteran Small Business Certification (vetcert) Database Https://veterans.certify.sba.gov Prior To Submission And Prior To Award Of Contract With Vaar 804.1103-70. Status As A Qualified Sdvosb Concern Is Under The Authority Of 38 Cfr Part 74 In Accordance With The Va Acquisition Regulation (vaar) Part 819. Any Person, Persons, Or Business Entity Suspected Of Misrepresenting Itself For The Purpose Of Securing A Government Contract May Be Criminally Investigated And Prosecuted For Fraud Against The United States Of America. Parties Found Misrepresenting Their Status Also Risk Debarment From Further Government Contracts. Eligible Sdvosb Concerns Must Also Be Registered At The Following Websites:
system For Award Management (sam): Https://www.sam.gov/
vets100/100a Report Must Be Complete: Http://www.dol.gov/vets/vets4212.htm
important Notice: Prior To Submitting A Package Under This Sdvosb Set- Aside Solicitation; Offerors Must Apply For And Receive Verification From The Small Business Administration In Accordance With 38 Cfr Part 74 And Vaar 819.70 By Submission Of Documentation Of Veteran Status, Ownership, And Control Sufficient To Establish Appropriate Status. All Offerors Are Urged To Contact The Sba And Submit The Required Documents To Obtain Verification Of Their Sdvosb Status If They Have Not Already Done So.
for A Service-disabled Veteran Owned Small Business (sdvosb) To Be Considered As A Prospective Contractor, The Firm, Including Joint Ventures, Must Be Verified And Registered In The Small Business Administration Veteran Small Business Certification (vetcert) Database (https://veterans.certify.sba.gov) And Registered In The System For Award Management (sam) Database (www.sam.gov) At Time Of Submission Of Their Qualifications. Failure Of A Prospective Sdvosb To Be Verified By The Center For Veterans Enterprise (cve) At The Time The Sf 330 Is Submitted Shall Result In Elimination From Consideration. All Joint Ventures Must Be Cve Verified At Time Of Submission And Submit Agreements That Comply With 13cfr 125.15 Prior To Contract Award.
sf 330 Selection Criteria: Evaluation Of Submission Requirements And Selection Criteria Are Provided Below And Listed In Relative Order Of Importance.
note: Failure To Meet An Acceptable Submission Requirements For Each Criteria Will Result In The Entire Submission Being Denied For Further Evaluation.
phase 1 Submission Requirements
objective Scoring:
Acceptable Submissions Meets All Submission Requirements
Unacceptable Submission Fails To Meet At Least One Submission Requirement
specialized Experience And Technical Competence In The Type Of Work Required.
submission Requirements:
sf 330 Information Shall Be Provided Per The Latest Format From The Gsa Library Located At Https://www.gsa.gov/forms-library/architect-engineer-qualifications.
complete Using Blocks F. And H. Of The Sf330 Form. Complete Block F. For Each Relevant Project. Complete Block H. Summary Sheet For The Offeror And Each Key Consultant; Each Summary Sheet Shall Be Not More Than One (1) Page In Length.
submit No More Than Five (5) Projects Similar To Required Work In The Solicitation From The Date The Solicitation Closes To Five (5) Years Prior;
at Minimum, Three (3) Projects Must Be Construction Complete Or Construction Substantially (50%+) Complete;
projects/data Submitted Shall Be Projects With Total Construction Costs Of $6,000,000 And Greater;
projects May Include Federal, State, Or Local Government, As Well As Private Industry Projects. Offerors Are Responsible For Providing Project Description And Applicable Information In Sufficient Detail To Permit Evaluation Of Project Relevancy Versus These Minimum Requirements.
past Performance On Contracts With Government Agencies And Private Industry In Terms Of Cost Control, Quality Work, And Compliance With Performance Schedules.
submission Requirements:
complete A Summary Sheet Using Block H. Of The Sf 330 Describing The Offeror S Past Performance. The Summary Sheet Shall Be Not More Than Two (2) Pages In Length.
provide The Contractor Performance Assessment And Reporting System (cpars), Interim And Final Reports, For Each Submitted Federal Entity Project Under Specialized Experience Criteria, Above. If A Cpars Is Not Available, Provide A Ppq.
if A Relevant Project Submitted Under Specialized Experience Criteria Does Not Have A Cpars Because It Is A Non-federal Entity Project, Provide A Past Performance Questionnaire (ppq).
cpar And Ppq Reports Will Not Count Towards Page Limitations.
professional Qualifications Necessary For Satisfactory Performance Of Required Services.
submission Requirements:
complete Using Block E. Of The Sf 330. Submit Personal Resumes And Relevant Information For Key And Responsible Personnel. Block E. Shall Be Not More Than One (1) Page In Length Per Individual.
the Offeror Shall Have A Professional Engineer, Currently Registered In Any Us State Or Territory Of The United States, Knowledgeable In Their Registered Design Discipline, To Be The Lead Designer Responsible For Reviewing And Approving Design Submissions.
the Offeror Shall Have A Professional Engineer, Qualified And Knowledgeable Of South Carolina State And Local Regulations, Be The Lead Designer Responsible For Reviewing And Approving Design Submissions And Facilitating Permit Documentation (depending On The Nature Of The Design I.e. Environmental, Hazardous Material Abatement, Stormwater, Etc.).
key Personnel To Provide Qualifications To Meet This Criterion Include Principal(s), Project Manager(s), Key Consultants, Individuals Responsible For Implementation Of The Design Qa/qc Plan, Licensed Asbestos Inspector, Physical Security Specialist, Life Safety Specialist, And Other Individuals That Are Responsible Or Accountable For Design Submissions And Regulatory Compliance.
physical Security Subject Matter Experts Shall Meet The Requirements Of Section 10.1.5 Of The Physical Security & Resiliency Design Manual.
experience In Construction Period Services.
submission Requirements:
complete Using Block H. Of The Sf 330. Provide A Narrative That Describes The Offeror S Performance Completing Construction Period Services (cps) For Construction For Each Submitted Project Under Specialized Experience Criteria, Above. Narrative Shall Be Not More Than Two (2) Pages In Length.
capacity To Accomplish The Work In The Required Time.
submission Requirements:
complete Using Block H. Of The Sf 330. Provide A Narrative That Describes The Offeror S Work Capacity. Narrative Shall Be Not More Than One (1) Page In Length.
location In The General Geographical Area Of Charleston, Sc, And Knowledge Of The Locality Of The Ralph H. Johnson Va Facility:
submission Requirements:
complete Using Block H. Of The Sf 330. Provide A Narrative That Describes The Offeror S Experience In The Charleston, Sc Geographical Area. Narrative Shall Be Not More Than One (1) Page In Length.
the Extent To Which Potential Contractors Identify And Commit To The Use Of Service-disabled Veteran-owned Small Businesses, Veteran-owned Small Businesses, And Other Types Of Small Businesses As Subcontractors:
submission Requirements:
complete Using Block H. Of The Sf 330. Provide A Narrative That Discusses The Offeror S Approach. Narrative Shall Be Not More Than One (1) Page In Length.
offerors Shall Complete And Submit The Following Statement In Block H. :
I [signatory Authority], Of [offeror Company Or Joint Venture] Certify That The Team Proposed To Perform Under This Requirement Demonstrates The Capability Of 50% Sdvosb Performance In Compliance Of 48 Cfr 852.219-10 .
phase 2 Evaluation Of Selection Criteria
specialized Experience And Technical Competence In The Type Of Work Required.
basis Of Evaluation:
specialized Experience Pertains To The Types, Size, Volume, Budget, And Complexity Of Work Previously Or Currently Being Performed By The Offeror That Is Comparable To The Work Covered By This Solicitation. Specialized Experience May Also Include Unique Conditions, Considerations, Or Circumstances Encountered That Are Relevant To This Solicitation.
specialized Experience Does Not Include Overseas Offices For Projects Outside The United States, Its Territories, Or Possessions; Nor Does It Include Subsidiaries That Are Not Normally Subject To Management Decisions, Accounting, And Policies, Or A Holding Or Parent Company Or An Incorporated Subsidiary That Operates Under A Firm Name Different From The Parent Company.
technical Competence Includes Construction And Design Projects Similar In Project Scope, Size, Construction Features, Dollar Value, And Complexity Of That Listed In The Solicitation. Technical Competence Also Includes Experience In Energy Conservation, Pollution Prevention, Waste Reduction, And The Use Of Recovered Materials.
similar Complexity Is Considered Projects Of An Operational, Construction, Or Design Likeness To The Work Covered In The Solicitation.
specific Emphasis Of Experience And Technical Competence Shall Be Geared Towards Fire Protection, Seismic Design/retrofit, Physical Security Resilience And Design, Healthcare Design/planning, Building Automatic System Design, And Mechanical/electrical System Design.
past Performance On Contracts With Government Agencies And Private Industry In Terms Of Cost Control, Quality Work, And Compliance With Performance Schedules.
basis Of Evaluation:
past Performance Is A Measure Of The Degree To Which An Offeror Satisfied Its Customers Needs And Requirements And Compliance With Applicable Codes, Standards, Laws, And Regulations. The Evaluation Of Past Performance Will Include But Is Not Limited To:
the Customer S Assessment Of The Offeror's Commitment To Customer Satisfaction;
timely Delivery Of Quality Work;
the Offeror's Record Of Conforming To Contract Requirements And Applicable Codes, Standards, Laws, And Regulations;
successful Implementation Of A Quality Control Plan And Quality Control Procedures;
addressing Design Errors/omissions Timely;
adherence To Approved Schedules; And,
history Of Timely And Professional Communication And Cooperative Behavior.
include Information On Problems (errors/omissions) Found, How The Problems Were Corrected, And The Impacts To The Successful Completion Of The Project (time Delays, Cost Impacts, Design Modifications, Etc.).
provide Information Supporting Favorable Cost Control, Quality Of Design Submissions, And Schedule Compliance.
include A Discussion On The Offeror S Record Of Significant Claims For Improper Or Incomplete Design Services.
higher Ratings May Be Given For Work Performed On Va Medical Center Campuses.
adjectival Rating:
offeror Risks Receiving A Lower Rating If Fewer Than Three (3) Ppqs Are Provided Or If The Ppqs Were Not Completed By Project Point Of Contact.
failure To Demonstrate Proven Competence To Perform Projects With Similar Requirements To The Requirements Of The Solicitation May Be Considered Ineligible For Award.
if No Cpars Or Ppqs Are Submitted Or Responses To Requests Were Not Provided, The Rating Shall Not Be Higher Than Satisfactory .
professional Qualifications Necessary For Satisfactory Performance Of Required Services.
basis Of Evaluation:
evaluation Of Professional Qualifications Will Include But Is Not Limited To The Subjective Assessment Of The Offeror's Individual Resumes.
the Offeror Shall Describe And/or Depict Which Projects And How Well Key Personnel Of The Design Team Have Worked Together.
higher Ratings For This Criterion May Be Given When The Offeror's Specific Personnel Demonstrate Relevant Credentials, Such As Involvement And Degree Of Involvement In Professional Organizations, Research/publications, Code/standard Body Involvement, Etc.
adjectival Scoring:
offerors Unable To Demonstrate Professional Qualifications Necessary To Perform Designs May Be Considered Ineligible For Award.
experience In Construction Period Services.
basis Of Evaluation:
experience In Construction Period Services To Include Professional Field Inspections During The Construction Period, Review Of Construction Submittals, Support In Answering Requests For Information During The Construction Period, And Support Of Construction Contract Changes To Include Drafting Statements Of Work, And Cost Estimates Shall Be Included As An Evaluation Criterion When Construction Period Services Is Included In The Statement Of Work For A-e Services.
evaluation Of The Offeror S Knowledge, Skills, And Abilities To Complete Necessary Cps To Support Successful Project Completion.
provide A Narrative Describing The Below Services, But Not Limited To:
professional Field Inspections, Both Scheduled And Emergent;
maintaining A Comprehensive Submittal Log Inclusive Of Material Data, Shop Drawings, Certifications, Etc.;
review Of Construction Submittals For Design Conformance, Variance, And Applicable Code/standard Compliance;
providing Timely And Complete Responses To Requests For Information;
providing Supporting Documentation (statements Of Work, Cost Estimates, Technical Reports, Etc.) For Construction Modifications;
providing Record Drawing Documentation;
process For Correcting Design Errors/omissions Identified During Construction; And,
other Requirements Defined Under Cps In The Statement Of Work.
capacity To Accomplish The Work In The Required Time.
basis Of Evaluation:
identify The Offeror S Past, Present And Projected Future Workload, Including Va Contracts Over The Previous 12 Months.
describe The Offeror S Capacity To Incorporate This Solicitation S Work While Meeting Prescribed Dates For Current Workload. Each Key Team Member To Include % Of Available Capacity To Take On New Projects.
evaluation Of This Factor Will Be An Assessment Of The Offeror S Ability To Complete Design Documents Within The Period Of Performance And Meet Solicitation Requirements.
data Is Acceptable In Tables Or Charts.
capacity < 25% Shall Be Rated Not Greater Than Satisfactory.
higher Ratings May Be Given For This Criterion When Information Provided Exceeds The Minimum Requirements.
location In The General Geographical Area Of Charleston, Sc, And Knowledge Of The Locality Of The Ralph H. Johnson Va Facility:
basis Of Evaluation:
offerors Will Be Subjectively Evaluated Based On Their Knowledge (and The Knowledge Of Subcontractors) Of Unique Conditions Or Variables, Such As Familiarity Of Applicable Codes, Regulations, Construction Market & Labor Conditions, Geotechnical, Seismic, Weather, Environmental, Or Other Unique Considerations Found In Charleston, Sc And The Low Country Geographical Area.
if Prior Experience In Charleston, Sc Is Minimal, Describe How The Design Team Plans To Obtain Specific Knowledge Of Local Conditions Or Project Features Required For A Compliant Design.
data From Other Projects And Locations Are Acceptable To Highlight Knowledge Of The Charleston, Sc Geographical Area Or Areas Of Similar Nature.
adjectival Scoring:
offerors That Submit Relevant Projects Outside Of The Charleston, Sc Geographical Area May Be Given A Lower Rating Than Projects Within The Charleston, Sc Geographical Area.
offerors That Demonstrate No Experience In The Geographical Area Shall Be Rated Not Higher Than Satisfactory .
the Extent To Which Potential Contractors Identify And Commit To The Use Of Service-disabled Veteran-owned Small Businesses, Veteran-owned Small Businesses, And Other Types Of Small Businesses As Subcontractors:
basis Of Evaluation:
offerors Shall Be Evaluated Based On Their Utilization Plans For Service-disabled Veteran-owned Small Businesses (sdvosbs), Veteran-owned Small Businesses (vosbs), Or Other Types Of Small Businesses.
offerors Shall Be Evaluated On The Expected Amount Of Work Versus Key Personnel To Verify The Above Signatory Statement. If Less Than 50% Of Work Is Estimated To Be Performed By The Prime Sdvosb, The Offeror May Be Given A Lower Rating.
offerors Shall Submit Qualifications For Proposed Consultants Per Other Criteria In This Solicitation.
selection Process:
federal Acquisition Regulation (far) Part 36.6 (brooks Act) Selection Procedures Apply. The A-e Services Listed Herein Is Being Procured In Accordance With The Brooks Act (public Law 92-582) As Implemented In Federal Acquisition Regulation (far) 36.6 And Vaar 836.6. Pursuant To Far, The Firm Responding To This Requirement Must Be Permitted, By Law, To Practice The Professions Of Architecture Or Engineering And Meet All Required Qualifications For The State Of South Carolina. Firms Responding To This Announcement By Submitting A Qualifying Sf 330, Before The Closing Date And Time, Will Be Considered For Initial Selection Evaluation. Following Initial Evaluation Of The Sf330s Received Three Or More Firms That Are Considered The Most Highly Qualified To Provide The Type Of Services Required Will Be Selected For Interviews. Selected Firms Will Be Notified By Email Of Selection And Provided Further Instructions.
selection And Evaluation Of Firms Shall Be Made Based On Sf 330 Submissions And Direct Responses To The Selection Criteria Identified Herein. Failure To Address All Selection Criteria Will Result In A Decreased Rating.
evaluating Past Performance And Experience May Include Information Provided By The Firm, Customer Inquiries, Government Databases, And Contracting Officer Knowledge Of Current Project Performance. Failure To Provide Requested Data, Accessible Points Of Contact Or Valid Phone Numbers Could Result In A Firm Being Removed From Consideration.
firms That Design Or Prepare Specifications In Conjunction With This Contract Are Prohibited From Participating On Any Future Construction Contracts Based On Those Documents. All Projects Identified On The Sf330 Must Be Completed By The Office/branch/individual Team Member Performing The Work Under This Contract.
submission Criteria/requirements: The Sf 330 Form May Be Downloaded From Http://www.gsa.gov/portal/forms/type/sf. Completed Sf 330 S Shall Include The Primary Firms, Subcontractor Firms And Any Consultants Expected To Be Used On The Project. Do Not Submit Information Incorporating By Reference. Prospective Firms Shall Address All Selection Criteria Factors Within Their Submitted Sf330 Packages.
email Capacity Is Limited To Five (5) To Seven (7) Megabytes (megs).
the Following Format Shall Be Used:
cover Page With Solicitation Number, Project Title
table Of Contents
sf 330 S
copy Of Current A/e License
copy Of Current Vetbiz.gov Sdvosb Certification
uei Number
cage Code
tax Id Number
the E Mail Address And Phone Number Of The Primary Point Of Contact.
all Sf330 Submittals And Questions Must Be Sent Electronically To The Attention Of Jennifer Smith, Contract Specialist At Jennifer.smith19c497@va.gov. Please Provide Pre-solicitation Number, Project Number, Project Title, And Firm Name In Subject Line Of Email. When Submitting Sf330s, If More Than One Email Is Sent, Please Number Emails In Subjects As 1 Of N . Submittals Received After The Date And Time Identified On Page One (1) Will Not Be Considered. Firms Not Providing The Required Information May Be Negatively Evaluated. Facsimile Submittals Will Not Be Accepted. All Information Must Be Included In The Sf330.
the Sf-330 Including Title Page, Table Of Contents, And Any Other Relevant Information Shall Be In A Common Font Size 12 Font, Single Spaced. The Package Shall Be Submitted As A Single Application-generated (not Scanned), Searchable Pdf Document. A Page Is Defined As Each Face Of An 8.5 X 11-inch Sheet Of Paper Containing Information.
it Is The Offeror S Responsibility To Check The Sam.gov Contracting Business Opportunities Website At: Www.sam.gov For Any Revisions To This Announcement Prior To Submission Of Sf330s.
attachments:
see Attached Document: Ae Past Performance Questionnaire And Cover Letter.
Closing Date5 Feb 2025
Tender AmountRefer Documents
VETERANS AFFAIRS, DEPARTMENT OF USA Tender
Civil And Construction...+1Building Construction
United States
Details: Synopsis:
project Title:
pre-solicitation Notice For Project 657-24-111jc Renovate Ambassador Suite & Main Lobby, Building 1, Saint Louis Va Medical Center John Cochran Division, Saint Louis, Mo.
contract Information
a. This A/e Services Requirement Is Being Procured In Accordance With The Brooks Act (public Law (pl0582) And Implemented In Accordance With The Federal Acquisition Regulation (far) Subpart 36. Firms Will Be Selected Based On Demonstrated Competence And Qualifications For The Required Work.
b. This Procurement Is Restricted To Service-disabled Veteran Owned Small Business (sdvosb) Firms. This Requirement Is Being Procured In Accordance With The Vaar 836.606-73 As Implemented In Far Subpart 36.6.
c. This Is Not A Request For Proposal, And An Award Will Not Be Made With This Announcement. This Announcement Is A Request For Sf 330 S From Qualified Contractors That Meet The Professional Requirements.
d. The Selection Criteria For This Acquisition Will Be In Accordance With Far 36.602-1 And Vaar 836.602-1 And Are Listed Below In Descending Order Of Importance. The Completed Sf 330 Will Be Evaluated By The St. Louis Va Medical Center Evaluation Board In Accordance With Far 36.602-5(a) And The Selection Report Shall Serve As The Final Selection List, Which Will Be Provided Directly To The Contracting Officer. The Government Will Not Pay Nor Reimburse Any Costs Associated With Responding To This Request. The Government Is Under No Obligation To Award A Contract As A Result Of This Announcement.
e. Award Of Any Resultant Contract Is Contingent Upon The Availability Of Funds.
f. No Solicitation Document Is Available And No Other Information Pertaining To Project Scope, Etc. Is Available At This Time. Any Request For Assistance With Submission Or Other Procedural Matters Shall Be Submitted Via Email Only To Abby.monroe2@va.gov And Arnold.payne@va.gov. Personal Visits To Discuss This Announcement Will Not Be Allowed.
g. The Naics Codes For This Procurement Is 541310 Architectural Services And Small Business Size Standard Of $12.5m. Award Of A Firm Fixed Price Contract Is Anticipated. The Anticipated Time For Completion Of Design Is Approximately 199 Calendar Days Including Time For Va Reviews. The Estimated Magnitude Of The Resulting Construction Price Range Is Estimated To Be Between $1,000,000 And $5,000,000.
h. Database Registration Information:
verification Of Status Of Apparently Successful Offeror This Acquisition Is 100% Set-aside For Qualified Service-disabled Veteran Owned Small Business Ae Firms Incompliance With Vaar 852.219-10. Only Businesses Verified And Listed In The Small Business Administration (sba) Registry Https://veterans.certify.sba.gov, Shall Be Considered.
system For Award Management (sam):
federal Acquisition Registrations Require That Federal Contractors Register In The System For Award Management (sam) Database At Www.sam.gov And Enter All Mandatory Information Into The System. Award Cannot Be Made Until The Contractor Has Registered. Offerors Are Encouraged To Ensure That They Are Registered In Sam Prior To Submitting Their Qualifications Package.
j. The Excluded Parties List System (epls):
to Ensure That The Individuals Providing Services Under The Contract Have Not Engaged In Fraud Or Abuse Regarding Sections 1128 And1128a Of The Social Security Act Regarding Federal Health Care Programs, The Contractor Is Required To Check The Excluded Parties List System (epls) Located At Www.sam.gov For Each Person Providing Services Under This Contract. Further The Contractor Is Required To Certify That All Persons Listed In The Qualifications Package Have Been Compared Against The Epls List And Are Not Listed. During The Performance Of This Contract The Contractor Is Prohibited From Using Any Individual Or Business Listed On The List Of Excluded Individuals/entities.
k. E-verify System:
companies Awarded A Contract With The Federal Government Shall Be Required To Enroll In E-verify Within 30 Days Of The Contract Award Date. They Shall Also Need To Begin Using The E-verify System To Confirm That All Of Their New Hires And Their Employees Directly Working On Federal Contracts Are Authorized To Legally Work In The United States. E-verify Is An Internet-based System That Allows An Employer, Using Information Reported On An Employee's Form I-9, To Determine The Eligibility Of That Employee To Work In The United States. There Is No Charge To Employers To Use E-verify. (far 52.222-54)
l. A/e Firms Are Required To Respond If Interested By Submitting One (1) Completed Standard Form 330 Qualification Package Parts I And Ii To Include All Consultants (form Available On-line At: Https://www.gsa.gov/system/files/sf330-21.pdf). Must Include In Part I Section H An Organizational Chart Of The Firm (excludes Consultants) And A Design Quality Management Plan. Submission Information Incorporated By Reference Is Not Allowed. All Submissions Shall Be Made Electronically.
m. Completed Package Shall Be Delivered Electronically On Or Before 1/17/2025 At 3:00pm Central Standard Time To The Nco 15 Contracting Office, Attn: Arnold Payne, Contracting Officer @ Arnold.payne@va.gov And Abby Monroe, Contract Specialist @ Abby.monroe2@va.gov.
project Information
the Mission Of The Veterans Affairs Saint Louis Health Care System (vastlhcs) Is To Provide The Highest Quality Health Care To Our Nation S Veterans. In Order To Accomplish This Mission, Vastlhcs Facility Engineering Service (fes) Intends To Partner With An A/e Firm On A Project To 657-24-111jc Renovate Ambassador Suite & Main Lobby, Building 1, John Cochran Division, St. Louis, Mo 63106. Project Will Renovate An Ambassador Entrance, Entrance Corridor, And The Ambassador Suite To Improve Patient And Ada Access To The Building, Fix Moisture And Leaking Issues With The Existing Skylight, Update Finishes, Improve Patient Circulation, And Optimize Space For The Existing Functions Operating In The Area As Well As Correct Hvac And Electrical Deficiencies, And Other Facilities Conditions Assessment Deficiencies Located Within The Area. The Main Entrance Of Bldg. 1 Will Be Updated To Facilitate Visitor Traffic Flow And Experience. The Existing Revolving Door Will Be Replaced With An Airlock Of Sliding And Swinging Doors With Automatic Controls.
supplement B
scope Of Work:
a/e Services Are Required For Schematics, Design Development, Construction Documents, Construction Cost Estimate And Construction Period Services For Project Number 657-24-111jc Renovate Ambassador Suite & Main Lobby, Building 1. This Delivery Order Shall Cover The Following Tasks.
a/e Part Two Services Of This Design Project (also Known As Construction Period Services) Includes Responding To Construction Contractor Requests For Information (rfis) During The Solicitation And Construction Phases Of The Construction Project, Attendance At Pre-bid, Post-award And Commissioning Kick Off Construction Project Conferences, Review Of Construction Material Submittals And Shop Drawings, Approximately 5 Site Visits During Construction To Ensure Compliance With The Design Drawings And Specifications, Preparation Of Site Visit Reports, Coordination With Project Commissioning Requirements, Review Of Any Construction Project Modifications For Cost And Technical Acceptability, Attendance In The Final Acceptance Inspection, Preparation Of The Punch List And Preparation Of Record Drawings Of The Completed Construction Project Based On The Construction Contractor S As-built Drawings. The A/e Shall Prepare A Submittal Log To Be Utilized By The Va During Construction Period Services, Maintain Rfi Log And Provide Meeting Minutes For Weekly Construction Meetings Throughout The Duration Of Construction. The A/e Shall Hire A Third-party Commissioning Agent To Commission All Installed Equipment.
the Above Paragraphs Constitute A Basic Outline Of The Work To Be Accomplished And In No Way Comprises All The Details For Design Of This Project. The A/e Shall Initiate Detailed Inspection Of The Project Site To Determine The Needs And Conditions For The Design Of This Project.
the A/e Shall Be Solely Responsible For The Management, Including All Associated Labor, Equipment, Materials, Mailing Costs, And Inspection, To Meet The Requirements Of The Design Project. The A/e Shall Further Provide Meeting Minutes For All Meetings Held Under This Design Project.
general Statement
a/e Part One Services (also Known As Design Phase) For This Design Project Includes Site Visit, Field Investigation, Conduct Of Studies And User Interviews To Update Drawings, Specifications And Cost Estimates For All Facets Of Work And Disciplines/trades To Facilitate A Construction Project. This Project Will Renovate Ambassador Suite & Main Lobby, Building 1
2. Design Development:
the A/e Firm Shall:
a. Meet With Facilities, And Other Personnel Prior To Start Of Design To Determine Detailed Requirements Of Work Involved.
b. Work From Existing Building And Site Drawings Furnished By The Va To Develop Project Design. (these Are To Be Used Only As Guidelines);
c. Perform Any Necessary On-site Field Investigations To Accomplish Work And To Verify Drawings Provided By The Va;
d. Prepare Rough Sketches, If Necessary, To Solve Possible Problems In Design Throughout The Contract; And
e. Follow Va Program Guide Pg-08-15 Volume C, And Other Applicable Guidelines To Design The Project.
3. Evaluation Factors:
selection Criteria Are In Accordance With Federal Acquisition Regulation (far) Part 36.602-5 And Va Acquisition Regulation (vaar) Part 836.602-1.â Prospective Firms Are Required To Address All Selection Criteria Within Submitted Sf330 Packages Using Additional Pages As Necessary.â Sf 330 Submissions Including Any Additional Pages Are Not To Exceed Fifty (50) Pages. Each Page Cannot Exceed 81/2 X 11 In Size.
qualifications (sf330) Submitted By Each Firm For Project Number: 657-24-111jc Renovate Ambassador Suite & Main Lobby, Building 1 Va Medical Center Saint Louis John Cochran Division Will Be Reviewed And Evaluated Based On The Following Evaluation Criteria Listed Below In Descending Order Of Importance:
1. Professional Qualifications: The Qualifications Of The Individuals Which Will Be Used For These Services Will Be Examined For Experience And Education And Their Record Of Working Together As A Team. A/e Firms Shall Have Licensed Professional Architects And Engineers Currently Registered In The State Of Missouri Or In A State Of Which Missouri Has Recognized The Engineering License. The Specific Disciplines Which Will Be Evaluated Are Architects, Civil Engineer, Mechanical Engineers, Electrical Engineers, Structural Engineers, Industrial Hygienists, Estimators, Cad Operators, Project Managers, Leed Consultant, Fire Protection Engineer, And Interior Designer.
2. Specialized Experience And Technical Competence: Provide Detailed Project Information On Any Projects (that Are Complete - Design And Construction) The Proposed Team Has Worked Together On In The Last Five (5) Years. Special Emphasis Will Be Given To Any Medical Facility Related Projects. If The Entire Team Has Not Worked Together Previously, Provide Detailed Project Information That Each Of The Team Members Have Worked On In The Last Three (3) Years With Special Emphasis On Medical Facility Projects. The Project Information Should Include Project Titles, A Short Scope Of Work, Date Of Design Completion, Date Of Construction Completion, Firms Involved, Etc. The A/e Shall Also Describe If They Have Any Experience Completing A Design That Was Started By Another A/e Firm. Provide The Project Title, Scope Of Work, Date Of Design Start For This Team, Percentage Of Design When Accepted By Team And Completion Of Design.
3. Capacity To Accomplish The Work. The General Workload And Staffing Capacity Of The Design Offices Which Will Be Responsible For The Majority Of The Design And The Ability To Accomplish The Work In The Required Time Will Be Evaluated.
4. Past Performance: Nco 15 Will Evaluate Past Performance On Recent And Relevant Contracts With Government Agencies (emphasis On Va Work) And Private Industry In Terms Of Construction Cost Estimating, Cost Control, Quality Of Work, Compliance With Performance Schedules And A Record Of Significant Claims Against The Firm Due To Improper Or Incomplete Engineering Services (references Required). Project Past Performances That Are Older Than 3 Years Will Receive A Lesser Score Than Those References For Projects Accomplished Within The Past 3 Years.
5. Location Of Design Firm: The Geographic Proximity Of Each Firm To The Location Of The Va Medical Center Will Be Evaluated. The Firm Must Be Capable Of Issuing Stamp Drawings In The State Where The Work Is Performed.â The Medical Center Is Located At Saint Louis, Va Medical Center, Saint Louis Missouri 63106.
6. Claims And Terminations: Provide Documentation Of Significant Claims Against The Firm Or Terminated Contracts Because Of Improper Or Incomplete Architectural And Engineering Services. Provide A Detailed Narrative Of Relevant Projects Within The Last 5 Years That Have Claims Against The Organization Or Have Been Terminated By The Owner. Include The Circumstances, Cost, And Schedule Impacts To Involved Parties, And Outcomes Of The Claims And/or Terminations. They Will Be Examined.
Closing Date17 Jan 2025
Tender AmountRefer Documents
NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY USA Tender
Civil And Construction...+2Consultancy Services, Civil And Architectural Services
United States
Details: Amendment 0001 - The Due Date For Qualifications Has Been Extended To Monday, January 13, 2025, 2:00pm Est. Government Responses To Rfi's Have Been Attached To This Notice.
description:
this Is A Request For Qualifications For Architect And Engineering (a&e) Services. This Request Is 100% Set-aside For Small Business’s Registered Under The Applicable Naics Code 541330 – Engineering Services, With A Size Standard Of $25,500,000.
the National Institute Of Standards And Technology (nist), An Agency Of The U.s., Department Of Commerce, Intends To Award Multiple Indefinite Delivery Indefinite Quantity (idiq) Contract(s) For General Architectural And Engineering (a/e) Services For The Nist Gaithersburg Campus Located At 100 Bureau Drive, Gaithersburg, Md 20899. A/e Services Under The Contract May Include The Following:
evaluation And Feasibility Studies To Include Engineering Modeling And Simulation
demolition Of Nist Structures, Utilities, And Infrastructure
repair And/or Repair By Replacement, Modification/reconfiguration, Building Additions, And Upgrades To Nist Facilities (e.g., Laboratories/scientific Research, Office, Industrial). Including But Not Limited To Architectural, Mechanical, Electrical, Communications, Structural, Fire Protection, And Building Enclosure (e.g., Roofs, Windows, Foundations).
repair And/or Repair By Replacement, Modification/reconfiguration For Campus Utility Systems And Supporting Underground Structures
comprehensive Historical Assessments For The Preservation, Rehabilitation, And Restoration Of Historic Property
interior Design Services Consisting Of Programming And Space Assessment, Fit Plans, And Office Furniture To Enhance Aesthetics, Comfort, Efficiency, And Workplace Safety.
cost Estimating For Different Levels (e.g., Concept, Detailed Program, Project)
life Cycle Cost Analysis Identifying Cost Elements From Initial Concept Through Operations, Support, And Disposal.
hazardous Material Survey And Risk Assessment (e.g., Asbestos, Mold, Lead Paint)
roofing And Waterproofing Services Such As Visual Inspections And Existing Conditions Surveys, Failure Investigation, And Design For Repairs.
commissioning Design Including Assistance Of Development Owner’s Project Requirements (opr), Design Document Reviews, Development Of Commissioning Specifications And Or Initial Commissioning Plan
program Of Requirements (por) Development By Meeting With Campus Personnel And Confirming Design Intent For Building And/or Major Systems (e.g., Mechanical, Electrical, Plumbing, Structural, Controls, Security, Fire Alarm, Etc.)
value Engineering Analysis To Achieve Design Goals While Lowering Life Cycle Costs And Maintaining The Required Performance, Quality, Reliability, And Maintainability.
record Drawings Development From Compiled As-built Set.
surveying (e.g., Alta/ascm, Boundary, Topographic, Construction, Site Planning)
roads/sidewalks Repairs And Replacement
evaluation Of Items Requiring Earthwork Such As Excavation, Grading, Ponds, Drainage, Foundation, And Footings
landscaping Design
gates, Fencing, And Related Engineering Necessary To Support A Campus Environment
permit Applications Submission To Regulatory Authorities Based On Specific Project Requirements. To Be Coordinated With Cor And Or Ahj For Acceptance And Or Approval
environmental Compliance (state Or Federal) Conforming To Laws, Regulations, Standards, And Other Requirements
construction Quality Management To Include But Not Limited To Commissioning Services
contract Information:
the Period Of Performance Of The Idiq Contract(s) Shall Be Five (5) Years. Annual Fully Burdened Labor Rates Will Be Negotiated Prior To Award. All Services Will Be Ordered Via The Issuance Of Individually Negotiated Firm-fixed-price Or Notto-exceed Task Orders, Ranging In Value From $10,000 And $2,000,000. Each Idiq Contract Shall Include A Guaranteed Minimum Order Of $5,000. The Cumulative Amount Of All Task Orders Shall Not Exceed $9,800,000.
the Government Anticipates Award Of Three (3) Or More Idiq Contracts; However, The Actual Number Of Awards Shall Be Made At The Discretion Of The Government.
submission Requirements:
consideration Will Be Limited To Professional A/e Firms Licensed And Registered In Maryland Who Provide A/e Services Primarily In The Disciplines Of Architectural, Civil, Structural, Mechanical, Electrical, And Environmental Engineering For Pre-design, Design, And Post-design Of Research Laboratory Facilities.
firms Meeting The Above Requirements And Desiring Consideration Must Submit Their Qualifications By No Later Than The Date Specified In This Announcement Via Email To The Following Addresses Using The Email Subject Line “rfq Submission – General Ae Services Idiq Nb195000-25-00009”:
Trent.stevens@nist.gov
Guzel.gufranova@nist.gov
Teresa.harris@nist.gov
qualification Submissions Shall Include One (1) Original Electronic Copy In Adobe .pdf Format Of Their Standard Form 330 (sf-330) With Appropriate Data. Ae Firms Shall Include All Subcontractor's Resumes In Part 1 Of The Sf-330. Part 2 Of The Sf-330, General Qualifications, Should Also Be Submitted For Each Subcontractor Or Consultant. Indicate The Solicitation Number On All Documentation Submitted.
along With The Sf-330, Offerors Shall Include:
a Copy Of Your Current Registration In System For Award Management (sam);
proof Of Small Business Status;
a Cover Page That Provides:
offeror’s Name And Address;
offeror’s Uei Number; And,
the Name, Title, Email, And Phone Number For The Authorized Representative Of The Offeror.
submissions Will Be Evaluated By A Source Selection Evaluation Board (sseb) And Ranked Based On The Stated Evaluation Factors. The Government Will Then Establish A Competitive Range; Firms That Fall Within This Range Will Be Invited To Present Their Capabilities To The Sseb. Formal Solicitations Requesting Fee Proposals Will Be Issued To The Highest Qualified Firms As Determined By The Government.
request For Information (rfi)
questions And Rfi's Must Be Submitted No Later Than 1:00pm Et On 12/10/2024 Via Email To The Following Addresses Using The Subject Line “rfi - General Ae Services Idiq Nb195000-25-00009” :
Trent.stevens@nist.gov
Guzel.gufranova@nist.gov.
the Contracting Officer Will Post Government Responses To Rfi’s On This Site As An Amendment To This Announcement. Firms Are Responsible For Monitoring This Site For Amendments To The Request For Qualifications.
selection Criteria:
all Work Performed Shall Be Under The Direct Control And Supervision Of A Professional And Experience Licensed Architect/engineer Employed By The Prime Contractor Assigned As The Responsible Party.
part I: Evaluation Of Sf-330
prospective A-e Firms Will Be Evaluated Based On Their Demonstrated Competence And Qualifications For The Type Of Professional Services Required. The Agency Will Evaluate Each Potential A-e Firm In Terms Of This Announcement. The Selection Criteria Are Listed Below In Descending Order Of Importance:
factor 1: Specialized Experience
page Limit – 15 Pages
firms Who Fail To Meet The Qualifications Of Factor 1 Will Not Be Evaluated On Subsequent Evaluation Factors And Will Not Be Considered For Award.
offeror Shall Demonstrate The Specialized Experience And Technical Competence Of Its Firm And Its Proposed Subcontractors Performing A/e Services Meeting The Criteria Of This Solicitation Within The Past Sixty (60) Months By Providing At Least 3 But No More Than 5 Example Projects (sections F, G, And H Of The Sf330) Addressing Each Of The Subfactors Listed Below (1a, 1b, 1c, And 1d). Offeror Shall Provide At Least One Example For Subfactor 1d. All Designs Shall Be Completed At Time Of Request For Qualifications (rfq). For The Purposes Of This Evaluations, “completed” Projects Shall Mean Projects Where Final Work Was Submitted, Approved, And Accepted By The Project Owner.
A. The Offeror Shall Describe Design For Renovations With Dates That Include Commercial Window Replacements, Masonry Repairs, And Roofing Repairs. Roofing Designs Are For Replacement Of An Existing Roofing System And Would Include Design And Specifications For New Built-up Roofs (at Least Three Ply) Of At Least 20,000 Sf Minimum, Including Drains, Coping And Flashing. Built Up Roofing Can Either Be Hot Or Cold Applied.
B. The Offeror Shall Also Describe With Dates Laboratory Design For Renovations Of At Least 2,000 Sf Which Include Replacement Or New Fume Hood Installation Of A Fume Hood At Least Four Feet In Width, New Laboratory Grade Casework, New Seamless Flooring, And Plumbing That Includes Either Eye Wash Station Or Safety Showers. Laboratories Shall Be For Commercial Facilities, Federal And State Facilities, Hospitals, And College/universities. High School And Lower School Grade Laboratories Will Not Be Considered.
C. The Offeror Shall Describe With Dates Designs That Include Laboratory Facility Mechanical, Plumbing, And Electrical Renovations, Upgrades And Alterations That Include Major Utility Systems, Facility Construction And Reconfiguration, Branch Circuits Of At Least 50 Amperes At 208v Or 480v, 3 Phase Power For Installation Of Specialized Scientific Tools, Equipment And Instrumentation (provide Amperage, Phases, And Voltages In Offer). The Contractor Shall Describe Distribution Of Manifold Specialty Gasses Utilizing At Least One Of The Following (nitrogen, Helium, Compressed Air, Or A Custom Blend) Within The Lab (note Which Gas Was In Manifold).
D. The Offeror Shall Describe, With Dates, Life Safety And Code Compliance Of The Following: Ibc And Nfpa Analyses, Access And Egress Analyses, Fire Alarm Systems And Device Designs, Nfpa 13 Fire Suppression System Modification Calculations And New Installations, And Hazardous Detection Systems (radiological Or Toxic Gas Monitoring Systems). Note Which Detection System (radiological Or Toxic Gas Monitoring System) Is Being Referenced.
factor 2: Professional Qualifications
page Limit – 17 Pages
the Offeror Shall Demonstrate The Technical Expertise And Professional Qualifications Of Its Proposed Team, Including Subcontractors And Consultants, To Perform The Required A/e Services By Providing Résumés (section E Of The Sf330) For All Of The Following Disciplines:
principle
senior Architect
senior Cost Estimator
senior Civil Engineer
senior Electrical Engineer
senior Fire Protection Engineer
senior Geo-technical Engineer
senior Laboratory Planner
mechanical Engineer (piping)
senior Mechanical Engineer (piping)
senior Mechanical Engineer (hvac)
senior Environmental Engineer
senior Scheduler
senior Surveyor
senior Water Proofing Engineer
senior Structural Engineer
2. Senior Positions Of Each Discipline Shall Have A Minimum Of Ten (10) Years Applicable Experience And Shall Be Licensed And/or Certified In Their Applicable Discipline.
3. The Offeror Shall Identify The Roles Of Its Key Personnel By Provide Resumes/sf 330s For Its Proposed Key Personnel That Include Credentials, Education, Registrations, Relevant Experience, And Their Role In Performing Requirements Outlined In Factor 1.
4. The Offeror Shall Submit An Organizational Chart Showing The Interrelations Of The Proposed Team Including All Subcontractors And Consultants.
factor 3: Geographical Location
page Limit – 1
offeror Shall Be Within 50 Miles Of The Nist Main Campus In Gaithersburg, Md. Nist Address Is 100 Bureau Drive, Gaithersburg, Md 20899. Offeror Shall Demonstrate This Distance By Submitting Information (driving) Via An Internet Mapping Program. The Driving Shall Begin At The Offeror’s Office To Nist.
factor 4: Capacity
page Limit – 2 Pages
the Offeror Shall Describe Their Team, Including Subcontractors, Capability To Complete Simultaneous Tasks Within The Required Timeframe Based On Current And Planned Workload And Expected Backlog.
the Offeror Shall Confirm That There Is Sufficient Capacity Within The Firm, Or That Additional Professional Capacity Can Be Increased As Needed In A Timely Manner To Deliver Projects That Meet The Government’s Specialized Requirements.
factor 5: Past Performance
page Limit – None
offeror Shall Provide Past Performance Information For The Relevant Projects Identified In Their Factor 1 – Specialized Experience Submission In The Form Of Either A Contractor Performance Assessment Reporting System (cpars) Report Or The Provided Past Performance Questionnaires (ppqs).
if The Project Was Completed For The Federal Government, The Offeror Shall Provide A Copy Of The Most Recently Completed Contractor Performance Assessment Reporting System (cpars) Report.
if No Cpars Is Available, Offeror Shall Use The Provided Past Performance Questionnaire (ppq). Ppqs Shall Be Completed And Signed By The Customer Identified In The Relevant Project. Limit Of One Ppq Per Project.
if An Offeror Submits Incomplete Past Performance Or Fails To Submit Any Past Performance Information, The Government May Evaluate Past Performance Based On The Information Obtained Concerning The Offerors’ Performance Relevant To Services Similar In Scope, Complexity, And Size For The Prime Contractor. Additionally, The Following Resources Will Be Used For Evaluation:
contractor Performance Assessment Reporting Systems (cpars), Or Similar Systems Of Other Government Departments And Agencies,
interviews Within Nist If Offeror Holds/held Previous Contracts,
interviews With Program Managers And Contracting Officers, And;
other Sources Known To The Government, Including Commercial Sources.
in The Case Of An Offeror Without A Cpars Record Of Relevant Past Performance Or For Whom Information On Past Performance Is Not Available, The Offeror Shall Be Rated Neither Favorably Nor Unfavorably.
part Ii: Oral Presentations
in Accordance With Far 36.602-3, The Government Will Hold Discussions With At Least Three Of The Most Highly Qualified Firms (firms Within The Competitive Range). More Details Related To The Presentations Will Be Provide To The Firms That Are Selected To Move Forward.
fee Proposal
only Those Firms Selected For Award Will Be Invited To Provide A Fee Proposal. Firms Shall Submit Along With Their Fee Proposal A Copy Of Audited Overhead Rate Statement Prepared In Accordance With The Federal Acquisition Regulation (far), Part 31 For The Prime And Their Sub-consultants. The Audit Must Be From A Federal, State, Local Government Or An Independent Third-party Auditor In Accordance With Far 31. Audit Conducted In Accordance With Generally Accepted Accounting Principles (gaap) Will Not Be Accepted.
Closing Soon13 Jan 2025
Tender AmountRefer Documents
VETERANS AFFAIRS, DEPARTMENT OF USA Tender
Civil And Construction...+2Others, Building Construction
United States
Details: Presolicitation Notice This Is A Pre-solicitation Notice, This Not A Request For Proposals. This Is A Request For Sf-330 Architect/engineer Qualification Packages Only. All Information Needed To Submit Sf330 Documents Is Contained Herein. No Solicitation Packages Or Technical Information Will Be Issued In This Phase. Site Visits Will Not Be Arranged During This Phase. Architect/engineering (a/e) Design Services Project: 521-25-104 | Remove Abandoned Equipment From Sub-basement And Mechanical Rooms Project Location: Birmingham Va Medical Center, 700 19th Street South, Birmingham, Al., 35233 Period Of Performance: 160 Days. Estimated Magnitude Of Construction: Between $1,000,000 And $2,000,000. Naics: 541330 Engineering Services. Size Standard: $25.5 Million. Set-aside: 100% Service-disabled Veteran Owned Small Business (sdvosb). The Department Of Veteran Affairs Network 7 Contracting Office Is Seeking Qualified Architect-engineering (ae) Firms To Submit Standard Form 330 (sf 330) Architect/engineering Statement Of Qualifications For Project # 521-25-104 | Remove Abandoned Equipment From Sub-basement And Mechanical Rooms | Birmingham Va Medical Center Facilities In Network 7 (state Of Alabama). Firms Submitting Qualification Packages Must Be Fully Licensed To Perform Designs As A Registered Professional Ae Firm In The United States To Be Considered For This Opportunity. Also, See Geographic Location Restriction In Paragraph 5 Of This Notice. Network Contracting Office (nco) 7 Va Facility Locations Include: Birmingham Va Medical Center, 700 19th Street South, Birmingham, Al., 35233. This Acquisition Is 100% Set-aside For Small Disabled Veteran-owned Small Business (sdvosb). Prospective Contractors Are Cautioned That Proposal Submitted In Response To This Solicitation Must Meet The Criteria Identified By 38cfr, Part 74. The Sdvosb Concern Agrees That In The Performance Of The Contract, The Concern Will Comply With The Limitation On Subcontracting Requirements In Accordance With Vaar Clause 852-219-73 (jan 2023) (deviation), Va Notice Of Total Set-aside For Verified Service-disabled Veteran-owned Small Businesses. For A Service-disabled Veteran Owned Small Business (sdvosb) To Be Considered As A Prospective Contractor, The Firm, Including Joint Ventures, Must Be Verified And Registered In The Vetcert (veterans.certify.sba.gov) And Registered In The System For Award Management (sam) Database (www.sam.gov) At Time Of Submission Of Their Qualification And Reporting To Vets - 4212 Federal Contractor Reporting In Accordance With Far 52.222-37, Employment Reports On Veterans At The Following Website: Dol.gov/agencies/vets/programs/vets4212. Failure Of A Prospective Sdvosb To Be Verified By The Veteran Small Business Certification At The Time The Sf 330 Is Submitted Shall Result In Elimination From Consideration. All Joint Ventures Must Be Cve Verified At Time Of Submission And Submit Agreements That Comply With 13 Cfr 125.15 Prior To Contract Award. Contract Overview A Firm Fixed Price A/e Design Service Contract Is Contemplated For Project 521-25-104 | Remove Abandoned Equipment From Sub-basement And Mechanical Rooms. The Estimated Magnitude Of Construction For This Project Is Between $1,000,000 And $2,000,000. The Estimated/target Design Completion Period Is 160 Calendar Days After Issuance Of Notice To Proceed. The Naics Code For This Acquisition Is 541330, Engineering Services With A Size Standard Of $25.5 Million. Project Scope: The A/e Team, Including Architects, Engineers, Surveyors, And Professional Consultants Shall Provide Complete Design Services For The Development Of Specifications And Drawings For Project 521-25-104 Remove Abandoned Equipment From Sub-basement And Mechanical Rooms. This Project Is To Remove Abandoned Pieces Of Equipment Such As Heat Exchangers, Air Dryers, Pumps, Etc. And All Associated Piping From Sub-basement And Mechanical Rooms Throughout The Facility. This Project Will Additionally Remove Abandoned Electrical Feeders And Concrete Pads. Work May Include, But Is Not Limited To, Architectural, Electrical, Hvac, Fire Protection And Plumbing. Systems Impacted May Include Fire Alarm, Security Access Systems, And Med Gas. Due To The Requirement For Site Visits And Coordination On Design Reviews, A/e Firms Will Be Required To Attend Various Meetings In Person On Site At Birmingham, Al Vamc Facilities. Due To This Requirement, The Area For Consideration For This Acquisition Is Restricted To A/e Firms With An Operating Office Located Within 400 Miles Of Birmingham Va Medical Center, 700 19th Street South, Birmingham, Al., 35233. Eligible Prime Contractor Firms Must Have A Main And/or Branch Office Geographically Located Within The 400-mile Driving Distance. Determination Of Mileage Eligibility Will Be Based On Upon Www.google.com/maps. Selection Criteria. The A/e Source Selection Team Shall Utilize The Following Selection Criteria Listed In Descending Order Of Importance. Professional: Professional Qualifications Necessary For Satisfactory Performance Of Required Service And Working Together As A Team (in-house And/or Consultants(s)). Note: The Firm And A/e On Staff Representing The Project Or Signing Drawings In Each Discipline Must Be Registered/licensed To Practice In The United States Provide Your Information On The Sf 330 Clearly Marked By Providing A Current Architect And/or Engineering License Numbers And Proof Of Licensure. The Va Will Confirm The Individuals Are Current And In Good Standing With The Respective State Licensing Board.â Specialized: Specialized Experience And Technical Competence In The Type Of Work Required, Including But Not Limited To: Architecture, Electrical, Plumbing, Mechanical, Fire Protection, Abatement/industrial Hygiene, Cost Estimation, Project Management And Where Appropriate, Experience In Energy Conservation, Pollution Prevention, Waste Reduction, And The Use Of Recovered Materials. Include Government And Private Experience On Similar Projects. Capacity: Capacity To Accomplish Work In The Required Time. This Factor Evaluates Firm's Experience With Similar Size Projects And The Available Capacity Of Key Disciplines When Evaluating The Capacity Of A Firm To Perform The Work In The Required Time. The General Workload And Staffing Capacity Of The Design Office Will Be Evaluated. List Current Projects With Similar Design Fee Being Designed In The Firms Office. Indicate The Firms Present Workload And The Availability Of The Project Team (including Sub-consultants) For The Specified Contract Performance Period; Describe Experience In Successfully Delivering Projects Per Performance Schedule, Providing Timely Construction Support, And Successfully Completing Multiple Projects With Similar Delivery Dates. Past Performance: Cpars Data Or Past Performance Questionnaires Must Be Provided For Projects Submitted Under Factor 2 (specialized Experience). Failure To Provide Requested Data, Accessible Points Of Contact Or Valid Phone Numbers Could Result In A Firm Being Considered Less Qualified. Past Performance As It Relates To Cost Control, Quality Of Work, And Compliance With Performance Schedules. The Following Information Is Required For All Projects: Contract/task Order Number, Project Title, Prime Firm, Start Date, And Completion Date. Evaluations May Also Include Additional Performance Related From The Firm, Customer Inquiries, Government Databases, Publicly Available Sources, And Additional Projects In Cpars. Past Performance Will Be Evaluated On Recent And Relevant Contracts With Government Agencies Or Private Industry. Recent Is Defined As Performance Occurring Within 5 Years Of The Date Of This Notice, Except That Ongoing Projects Must Have Begun No Less Than One (1) Year Prior To The Issuance Of This Notice. Relevancy Is Defined As Performance Of Work On Projects That Are Similar In Scope To The Types Of Projects Anticipated Under The Resultant Contracts. Respondents With No Previous Past Performance Shall State This When Addressing The Selection Criteria. Where There Is No Record Of Past Performance, The Proposal Will Be Evaluated Neither Favorably Nor Unfavorably. Location: Knowledge Of The Locality, To Include Specific Knowledge Of Certain Local Conditions Or Project Site Features, Such As Geological Features, Climatic Conditions, Local Construction Methods, Construction Firms And Trades Labor Availability, And Local Laws And Regulations. That Your Proximity To The General Geographical Area Enables You To Respond To Emergency Calls In Person Within 24 Hours If Required. (sf 330 Submittal Should Show Your Knowledge Of The Locality Of The Project.) Eligible Prime Contractor Firms Must Have A Main And/or Branch Office Geographically Located Within The 400-mile Radius. Distance Will Be Determined By Google Maps. Commitment: The Extent To Which Potential Contractors Identify And Commit To The Use Of Service-disabled Veteran-owned Small Businesses, Veteran-owned Small Businesses, And Other Types Of Small Businesses As Subcontractors. Construction Period Services: Experience In Construction Period Services To Include Professional Field Inspections During The Construction Period, Review Of Construction Submittals, Support In Answering Requests For Information During The Construction Period, And Support Of Construction Contract Changes To Include Drafting Statements Of Work, And Cost Estimates. Reputation: Standing/reputation Of The Firm And Its Principal Officials With Respect To Professional Performance, General Management, And Cooperativeness. Mention Applicable Awards, Outstanding Merits, And Recommendations. Additional Experience: Specific Experience And Qualifications Of Personnel Proposed For Assignment To The Project. Selection Procedures. This Requirement Is Being Procured In Accordance With The Brooks Act Of 1972, Federal Acquisition Regulation 36.6 (far) And Va Acquisition Regulation 836.6 (vaar) And Va Acquisition Manual (vaam) 836.6. Firms Responding To This Announcement By Submitting A Qualifying Sf 330, Before The Closing Date And Time, Will Be Considered For Initial Selection Evaluation. Following Initial Evaluation Of The Sf330s Received Three Or More Firms That Are Considered The Most Highly Qualified To Provide The Type Of Services Required Will Be Selected For Interviews. Selected Firms Will Be Notified By Telephone Or Email Of Selection And Provided Further Instructions. Selection And Evaluation Of Firms Shall Be Made Based On Sf 330 Submissions And Direct Responses To The Selection Criteria Identified Herein. Failure To Address All Selection Criteria Will Result In A Decreased Rating. Evaluating Past Performance And Experience May Include Information Provided By The Firm, Customer Inquiries, Government Databases, And Contracting Officer Knowledge Of Current Project Performance. Failure To Provide Requested Data, Could Result In A Firm Being Removed From Consideration. If Relevant Cpars Evaluation(s) Are Available, Report(s) Shall Be Submitted With The Completed Sf330 Package. If There Is Not A Completed Cpars Evaluation, The Ppq Included With This Notice Is Provided For The Offeror Or Its Team Members To Submit For Each Project Included In Criterion (2). Official Cpars Evaluation(s) Found In In Government Databases Will Take Precedence. Completed Ppqs Should Be Submitted With Your Sf330. Firms That Design Or Prepare Specifications In Conjunction With This Contract Are Prohibited From Participating On Any Future Construction Contracts Based On Those Documents. All Projects Identified On The Sf330 Must Be Completed By The Office/branch/individual Team Member Performing The Work Under This Contract. Submission Requirements. The Sf 330 Form May Be Downloaded From Http://www.gsa.gov/portal/forms/type/sf. Completed Sf 330 S Shall Include The Primary Firms, Subcontractor Firms And Any Consultants Expected To Be Used On The Project. Do Not Submit Information Incorporating By Reference. Prospective Firms Shall Address All Selection Criteria Factors Within Their Submitted Sf330 Packages. The Following Format Should Be Used: Cover Page With Solicitation Number, Project Title. Table Of Contents. Sf 330. Acceptability Under Other Appropriate Evaluation Criteria, I.e., Sf 330, Section H. Copy Of Current A/e State Engineer/architect License. Unique Entity Id (uei). Tax Id Number. The E Mail Address And Phone Number Of The Primary Point Of Contact. Sf 330 Date Of Receipt/due Date: Interested Firms Having The Capabilities To Perform This Work Must Submit One (1) Electronic Sf 330 And Attachments (as Applicable) No Later Than 01/21/2025 At 1:00 P.m. Et. Email Capacity Is Limited To Ten (10) Megabytes (mbps). All Sf330 Submittals And Questions Must Be Sent Electronically To The Attention Of Contracting Officer Gregory Snyder, Gregory.snyder@va.gov. Please Also Copy Ryan.crispin@va.gov And Joseph.osborn@va.gov In Emailed Sf 330 Package. Please Include The Pre-solicitation Number, Project Title, And Firm Name In Subject Line Of Email. When Submitting Sf330s, If More Than One Email Is Sent, Please Number Emails In Subjects As 1 Of __ . Submittals Received After The Date And Time Identified On Page One (1) Will Not Be Considered. Firms Not Providing The Required Information May Be Negatively Evaluated. Facsimile Submittals Will Not Be Accepted. All Information Must Be Included In The Sf330. The Sf-330 Including Title Page, Table Of Contents, And Any Other Relevant Information Shall Not Exceed A Total Of 50 Pages In A Common Font Size 12 Font, Single Spaced. The Proposal Shall Be Submitted As A Single Application-generated (not Scanned), Searchable Pdf Document. A Page Is Defined As Each Face Of An 8.5 X 11-inch Sheet Of Paper Containing Information. The Page Limitation Does Not Apply To The Licenses, Contract Performance Evaluations, (i.e., Cpars) And Award Documentation. This Information Should Be Provided As Attachments To The Sf 330. All Questions Regarding This Announcement Must Be Emailed To The Contracting Officer Gregory.snyder@va.gov No Later Than 01/14/2025 By 1:00 P.m. Et. Site Visits Will Not Be Arranged During This Phase. This Announcement Is Not A Request For Proposal. This Is A Pre-solicitation Notice For Architect/engineering (a/e) Design Services; No Solicitation Package Will Be Issued Until After An Evaluation Has Been Made On The Provided Sf-330. Only The A/e Firms Responding To This Announcement By Submitting An Sf330 Package On Time Will Be Considered For Initial Evaluation.
Closing Date21 Jan 2025
Tender AmountRefer Documents
DEPT OF THE ARMY USA Tender
Civil And Construction...+1Civil Works Others
United States
Details: 1. Contract Information: This Contract Is Being Procured In Accordance With The Brooks A-e Act As Implemented In Far Subpart 36.6. Firms Will Be Selected For Negotiation Based On Demonstrated Competence And Qualifications For The Required Work. See Numbered Note 24 For General Information On The A-e Selection Process. A-e Services Are Required For Site Investigation, Concept Design, Final Design (option), And Construction Phase Services (option) For The Subject Project. North American Industrial Classification System Code Is 541330, Which Has A Size Standard Of $25,500,000 In Average Annual Receipts. This Announcement Is Open To All Businesses Regardless Of Size. Far Clause “52.219-4 Notice Of Price Evaluation Preference For Hubzone Small Business Concerns” Will Be Included In The Solicitation. A Firm-fixed-price Contract Will Be Negotiated. The Contract Is Anticipated To Be Awarded In Sep 2025 And Design Completed By Oct 2028. A-e Contract Price Is Estimated To Be More Than $10,000,000. If A Large Business Is Selected For This Contract, It Must Comply With Far 52.219 -9 “small Business Subcontracting Plan” Regarding The Requirement For A Subcontracting Plan On That Part Of The Work It Intends To Subcontract. This Action Will Be Subject To Far Clause 52.219-14 “limitations Of Subcontracting.” For The Purposes Of This Solicitation, This Acquisition Is To Be Considered A Service And As Such, The Government Will Not Pay More Than 50% Of The Amount Paid By The Government For Contract Performance To Subcontractors That Are Not Similarly Situated Entities. Any Work That A Similarly Situated Entity Further Subcontracts Will Count Towards The Prime Contractor's 50% Subcontract Amount That Cannot Be Exceeded. When A Contract Includes Both Services And Supplies, The 50% Limitation Shall Apply Only To The Service Portion Of The Contract; The Subcontracting Goals For The New York District Which Will Be Considered In The Negotiation Of This Contract Are: (1) At Least 25%, But No More Than 49% Of A Contractor's Intended Subcontract Amount Be Placed With Small Businesses (sb); (2) At Least 5 % Of A Contractor's Intended Subcontract Amount Be Placed With Small Disadvantaged Businesses (sdb); (3) At Least 3% Of A Contractor's Intended Subcontract Amount Be Placed With Women-owned Sb (wosb); (4) At Least 3% Of A Contractor's Intended Subcontract Amount Be Placed With Service-disabled Veteran-owned Sb; (5) At Least 3% Of A Contractor's Intended Subcontract Amount Be Placed With Veteran-owned Sb; And (6) At Least 3% Of A Contractor's Intended Subcontract Amount Be Placed With Hubzone Sb. The Plan Is Not Required With This Submittal, But Will Be Required With The Fee Proposal Of The Firm Selected For Negotiations. To Be Eligible For Contract Award, A Firm Must Register For An Unique Entity Id, A 12-character Alphanumeric Id Assigned To An Entity By Sam.gov. New Entities Can Get Their Unique Entity Id At Sam.gov And Complete An Entity Registration.
2. Project Information: Replace, By Deconstruction And Reconstruction, A Multi-story General Instruction Building. Rehabilitate The Original Features Of The Building Constructed In 1911 Which Have Survived. The Primary Facility Will Provide Spaces For General Instruction Classrooms, Lecture Halls And Collaboration Space, Administrative Space With Private And Open Offices, An Auditorium, Lab Space, Conference Rooms, Reception Areas, A Library And Mock Courtroom, An Arms Vault, Showers And Bathrooms, Lactation Rooms, Copy Rooms, Staff Break Rooms, Departmental Storage, Vending Areas And A Cafe, As Well As Freight And Passenger Elevators. Cybersecurity Measures, Electronic Security Systems (pacs & Ids) Installation, Energy Measurement And Control System (emcs) Connection, Building Information Systems, And Fire Alarm And Protection Systems Will Be Included. Supporting Facilities Include Utility Connections (water, Sanitary Sewer, Electrical), Storm Drainage, Walks, Curbs And Gutters, Landscaping, And Site Improvements. Heating Will Be Provided By District Heat, And Air Conditioning Will Be Provided By A Steam Powered Absorptive Chiller System. Comprehensive Building And Furnishings Related Interior Design Services Are Required. This Project Will Be Designed For Accessibility And Usability By Individuals With Disabilities. Utility Connections Are Required To Privatized Electric Distribution, Water, And Wastewater Systems. The Army Intends To Have The Respective Utilities Privatization System Owners, American Water And City Light & Power Make And Own The Necessary Connections Up To The Facility Service Disconnect Or Other Defined Point Of Demarcation. Facilities Will Be Designed To A Minimum Life Of 40 Years In Accordance With Dod's Unified Facilities Criteria (ufc 1-200-02) Including Energy Efficiencies, Building Envelope And Integrated Building Systems Performance. Demolish The Portion Of The Building Constructed In 1955 (321,012 Total Sf). U.s. Military Academy (usma) Has A Substantial Deficit Of -412,799 Square Feet In General Instructional Space, And This Project Will Address A Portion Of That Deficit By Constructing A New Addition. The New Addition, Exterior Alterations, And Related New Construction Will Not Destroy Historic 1911 Materials, Features, And Spatial Relationships That Characterize The Property. The New Work Will Be Differentiated From The Old And Will Be Compatible With The Historic Materials, Features, Size, Scale And Proportion, And Massing To Protect The Integrity Of The Property And Its Environment. The New Addition And Adjacent Or Related New Construction Will Be Undertaken In Such A Manner That, If Removed In The Future, The Essential Form And Integrity Of The Historic 1911 Property And Its Environment Would Be Unimpaired. Moreover, This Project Will Consolidate Key Programs In One Facility. By Upgrading And Consolidating Key Programs Into A Central Location Within The Main Campus, The Academy Aims To Foster A More Cohesive Academic Environment While Addressing Its Instructional Space Deficit. The Centralization Of Programs Will Reduce The Physical Fragmentation Of Departments And Encourage More Cross-disciplinary Collaboration. This Approach Aligns With Modern Educational Trends, Where Academic Institutions Are Moving Towards Flexible, Multi-purpose Spaces That Encourage Interaction And Innovation. Bringing Key Programs Together In Adequately Sized Spaces Will Not Only Optimize The Use Of Space But Also Create An Atmosphere Where Students And Faculty From Different Disciplines Can Engage In Meaningful Collaboration, Enhancing The Learning Experience. This Project Is Required To Update The Flagship Schoolhouse, Thayer Hall, As Part Of The Academic Building Upgrade Program (abup), Which Was Conceived To Address Critical Gaps In Instructional Space And Ensure That Academic Buildings Meet Both The Current And Future Needs Of The Usma's Academic Departments. Thayer Hall Will Support A Student Load Of 2,880 Students. The Project's Primary Goal Is To Reduce The Instructional Space Deficit. By Upgrading The Instructional Facilities, The Academy Seeks To Align Itself With Contemporary Educational Standards, Which Prioritize Collaborative Learning, Cross-disciplinary Interaction, And Active Engagement Between Students And Faculty. The Contract Will Require Accomplishment Of Site Investigation Work. The Contract Will Require Preparation Of Parametric Design Considered To Be 5 – 15 Percent Of The Total Design Effort. The Contract Will Require Preparation Of Concept Design Considered To Be 35 Percent Of The Total Design Effort. As An Option, The Contract Will Require Preparation Of 60%, 90%, And Final 100% Designs. As An Option, The Contract Will Require Delivery Of Construction Phase Ae Services. The Estimated Construction Cost Of This Project Is Over $500,000,000. Cost Estimates Must Be Prepared Using The Corps Of Engineers Micro Computer Aided Cost Estimating System (mcaces) – Second Generation (mii). The Contractor Shall Be Responsible For Accomplishing Designs And Preparing Drawings Using Advanced Modeling And Delivering The Three-dimensional Drawings In Autodesk Revit And Autodesk Civil 3d Software. The Government Will Only Accept The Final Product For Full Operation, Without Conversion Or Reformatting, In The Target Advanced Modeling Software Format, And On The Target Platform Specified Herein. Drawings Shall Be Compliant With The Current A/e/c Cad Standard Available From The Cad/bim Technology Center, Engineer Research And Development Center.
3. Selection Criteria: The Selection Criteria For This Particular Project Are Listed Below In Descending Order Of Importance (first By Major Criterion And Then By Each Sub- Criterion). Criteria A-e Are Primary. Criteria F-g Are Secondary And Will Only Be Used As "tie-breakers" Among Firms That Are Essentially Technically Equal.
a. Submit No More Than Ten Projects Which Demonstrate Specialized Experience And Technical Competence In Design Of Facilities Similar To The Project Described Herein. Submitted Projects Should Have A Construction Cost Of At Least $100,000,000. Submitted Projects Should Have A Construction Completion Date No Earlier Than January 2015. On All Example Projects, The Government May Consider The Following Strengths For Evaluation Purposes:
(1) Design Of Facility Renovations For Older/historic Institutions Of Higher Learning.
(2) Application Of The Secretary Of The Interior’s Standards For The Treatment Of Historic Properties And Compliance With Section 106 Of The National Historic Preservation Act.
(3) Sustainable Design Using An Integrated Design Approach And Emphasizing Environmental Stewardship, With Experience In Energy And Water Conservation And Efficiency; Use Of Recovered And Recycled Materials; Waste Reduction; Reduction Or Elimination Of Toxic And Harmful Substances In Facilities Construction And Operation; Efficiency In Resource And Materials Utilization; Development Of Healthy, Safe, And Productive Work Environments; And Employing The Leed Evaluation And Certification Methods.
(4) Conducting Whole Building Life Cycle Cost Analysis (wb Lcca) Considering The Cradle-to-grave Costs Associated With Upfront Construction, Lifetime Building Sustainment, Maintenance, Operations (including Energy And Water Use), And Building Disposal, To Target The Most Cost-effective Design To Achieve Modeled Building Energy Consumption Reduction By A Minimum Of 30% Below The Ashrae 90.1 Baseline Specified In 10 Cfr 433 Without The Use Of Fossil Fuel Combustion Systems, With The Goal Being To Select The Optimal Combination Of Interdependent Building Systems (e.g. Envelope, Hvac, Hot Water, Lighting, Wall And Floor Thermal Mass Capacity, Etc).
(5) Design Of Resilient Buildings, I.e. A Building That (i) Maximizes The Ability Of The Owner/operator To Withstand And Recover From A Potentially Disruptive Event That May Adversely Affect Mission Assurance And Mission-essential Functions, Including Extreme Weather (as Defined By 10 U.s.c. 101(a)(20)) Or A Disruption To Energy Or Water Supplies; (ii) Has Minimal Energy And Water Demand; (iii) Has An Indoor Environment Optimized To Promote Human Safety, Physical And Psychological Health, And Productivity; And (iv) Integrates Carbon-free Energy Generation And Storage.
(6) Design Of Building Stabilization And Structural Shoring And Bracing Systems.
(7) Experience Of The Prime Firm And Significant Subconsultants, Particularly The Cost Engineering Firm, The Geotechnical Drilling Firm, And The Asbestos/lead/pcb/hazmat Consulting Firm, In Working Together.
b. Qualified Professional Personnel In The Following Key Disciplines: Aabc Certified Commissioning Authority (cxa), Accredited Learning Environment Planner (alep), Architecture, Asbestos/lead/pcb/hazmat Consulting, Certified Value Specialist, Civil Engineering, Clc Or Cld Certified Lighting Consulting, Comptia Certified Cybersecurity Consulting, Construction Project Scheduler Experienced With Primavera P6, Cost Engineering, Cts Certified Audio/visual Consulting, Electrical Engineering, Electronic Security Engineering, Fire Protection Engineering, Geotechnical Engineering, Historic Preservation Architecture, Ince Certified Acoustical Consulting, Land Surveying, Landscape Architecture, Leed Accredited Professional, Mechanical Engineering, Ncidq Or State Licensed Interior Design, Project Management, Structural Engineering, Telecommunications Engineering, And Vertical Transportation Engineering. The Lead Architect Or Engineer In Each Discipline Must Be Registered To Practice In The Appropriate Professional Field. The Civil Engineer, Asbestos/lead/pcb/hazmat Consultant And Land Surveyor Must Be Registered To Practice In New York. The Evaluation Will Consider Education, Certifications, Training, Registration, Overall And Relevant Experience, And Longevity With The Firm.
c. Past Performance On Dod And Institution Of Higher Learning Contracts With Respect To Cost Control, Quality Of Work, And Compliance With Performance Schedules, As Determined From Cpars And Other Sources.
d. Capacity To Submit The Draft Parametric Design Report (pdr) (10% Complete) By January Or February 2026, To Submit The Corrected Pdr (15% Complete) By April 2026, To Submit The Draft Concept Design (30% Complete) By June Or July 2026, To Submit The Corrected Concept Design (35% Complete) By September 2026, To Submit The 35% Certification Package (consisting Of Final Eng 3086, Designated Construction Agent Assessment Eng 6196, And Cost Schedule Risk Analysis Documentation) By November 2026 And Complete The Final Design (option) By October 2028. Schedule Is Critical For The Project. The Evaluation Will Consider The Experience Of The Firm And Any Consultants In Similar Size Projects, And The Availability Of An Adequate Number Of Personnel In Key Disciplines.
e. Knowledge Of Design Of Foundations Bearing On Granite Or Gneiss Bedrock, Design Of Building Systems For Marine, Mixed-humid, And Cold Climate Zones, Rehabilitation Of Historic Stone Masonry, Design Complying With The Department Of Defense (dod) Unified Facilities Criteria, Design Complying With The Department Of The Army Policy Guidance On Resilient Buildings, Or Design Subject To Review By The New York State Historic Preservation Officer Or The New York State Department Of Environmental Conservation.
f. Extent Of Participation Of Sb (including Wosb), Sdb, Historically Black Colleges And Universities, And Minority Institutions In The Proposed Contract Team, Measured As A Percentage Of The Total Estimated Effort.
g. Volume Of Dod A-e Contract Awards In The Last 12 Months, With The Objective Of Effecting An Equitable Distribution Of Dod A-e Contracts Among Qualified Firms, Including Sb And Sdb.
4. Submission Requirements: Interested Firms Having The Capabilities To Perform This Work Must Submit Sf 330 Part I And Sf 330 Part Ii For The Prime Firm And All Consultants, To Jordan.k.moran@usace.army.mil Not Later Than 11:59 Pm Est On The Response Date Indicated Above. The Sf 330 Part I Shall Not Exceed 100 Pages (pdf Formatted To 8.5” X 11” Page Size), Including No More Than 50 Pages For Section E. Use No Smaller Than 12 Font Type. The Firm Is Encouraged, But Not Required, To Include Their Sam.gov-assigned Unique Entity Id Number In Sf 330, Part I, Section H. In Section H Describe The Firm's Overall Design Quality Management Plan (dqmp). A Project-specific Design Quality Control Plan Must Be Prepared And Approved By The Government As A Condition Of Contract Award But Is Not Required With This Submission. In Section H Also Indicate The Estimated Percentage Involvement Of Each Firm On The Proposed Team. The Most Highly Qualified Firms Will Be Interviewed. Neither Facsimile Nor Paper Hardcopy Transmissions Will Be Accepted. Solicitation Packages Are Not Provided, And No Additional Project Information Will Be Given To Firms During The Announcement Period. This Is Not A Request For Proposal. The Government Intends To Notify Interested Firms Of The Selection Or Non-selection Decision By March 2025.
point Of Contact: Jordan Moran, (917) 908-8121
email Your Questions To Us Army Corps Of Engineers New York District At Jordan.k.moran@usace.army.mil
Closing Date17 Jan 2025
Tender AmountRefer Documents
Bureau Of Corrections Muntinlupa City Metro Manila Tender
Civil And Construction...+1Building Construction
Philippines
Details: Description Republic Of The Philippines Department Of Justice Bureau Of Corrections Muntinlupa City Philippine Bidding Documents Design And Build Of Bureau Of Corrections Supermaximum Prison Facility (2nd Phase) At Sablayan Prison And Penal Farm (sppf) (procurement/contract No. 009) Sixth Edition July 2020 Bids And Awards Committee 202 Table Of Contents Section I. Invitation To Bid 3 Section Ii. Instructions To Bidders 6 Section Iii. Bid Data Sheet 13 Section Iv. General Conditions Of Contract 19 Section V. Special Conditions Of Contract 24 Section Vi. Specifications 26 Section Vii. Drawings 59 Section Viii. Bill Of Quantities 60 Section Ix. Checklist Of Technical And Financial Documents 61 Section I. Invitation To Bid Republic Of The Philippines Department Of Justice Bureau Of Corrections Muntinlupa City Invitation To Bid Design And Build Of Bureau Of Corrections Supermaximum Prison Facility (2nd Phase) At Sablayan Prison And Penal Farm (sppf) 1. The Bureau Of Corrections, Through The National Expenditure Program (nep) Of 2025 Capital Outlay, Intends To Apply The Sum Of Three Hundred Million Pesos Only (₱300,000,000.00) Being The Approved Budget For The Contract (abc) To Payments Under The Contract For The Design And Build Of Bureau Of Corrections Supermaximum Prison Facility (2nd Phase) At Sablayan Prison And Penal Farm (sppf) With Identification Number _epa-009__. Bids Received In Excess Of The Abc Shall Be Automatically Rejected At Bid Opening. 2. The Bureau Of Corrections Now Invites Bids For Provision Of A Detailed Preliminary Architectural And Engineering Design, Detailed Engineering Requirements And Actual Construction Of The Bureau Of Corrections Super Maximum Security Facility, Based On The Final Detailed Architectural And Engineering Design, To Be Approved By The Head Of Procuring Entity Or Its Duly Authorized Representative Conformably With The Minimum Standards Set Forth In The (1) Presidential Decree (pd) No. 1096, National Building Code Of The Philippines (2) Batas Pambansa (bp)blg. 344, An Act To Enhance The Mobility Of Disabled Persons By Requiring Certain Public Buildings, Institutions, Establishments And Public Utilities To Install Facilities And Other Devices (3) National Structural Code Of The Philippines (nscp), Volume I, 2010 (4) Philippine Electrical Code (pec), 2009 (5) Revised Plumbing Code Of The Philippines (6) Revised Irr Of Ra 10575 (7) Republic Act (ra) No. 9514, Revised Fire Code Of The Philippines And (8) Applicable Local Regulations And Ordinances. Completion Of The Works Is Required Within Three Hundred Sixty-five (365) Calendar Days. Bidders Should Have Completed A Contract Similar To The Project Amounting To At Least Fifty Percent (50%) Of The Abc Within The Last Six (6) Years. The Description Of An Eligible Bidder Is Contained In The Bidding Documents, Particularly, In Section Ii. Instructions To Bidders. 3. Bidding Will Be Conducted Through Open Competitive Bidding Procedures Using Non-discretionary “pass/fail” Criterion As Specified In The 2016 Revised Implementing Rules And Regulations (irr) Of Republic Act 9184 (ra 9184), Otherwise Known As The “government Procurement Reform Act.” Bidding Is Restricted To Filipino Citizens/sole Proprietorships, Cooperatives, And Partnerships Or Organizations With At Least Seventy-five Percent (75%) Interest Or Outstanding Capital Stock Belonging To Citizens Of The Philippines. 4. Interested Bidders May Obtain Further Information From Bureau Of Corrections And Inspect The Bidding Documents At The Address Given Below From Monday To Friday From 8:00am To 5:00pm. 5. A Complete Set Of Bidding Documents May Be Acquired By Interested Bidders On _december 28, 2024 (08:00am To 05:00pm) To January 20, 2025 (01:29 Pm)_____ From The Given Address And Website(s) Below. It May Also Be Downloaded Free Of Charge From The Website Of The Philippine Government Electronic Procurement System (philgeps) And The Website Of The Procuring Entity Bucor.gov.ph, Provided That Bidders Shall Pay The Applicable Fee Of Fifty Thousand (₱50,000.00) Pesos Only For The Bidding Documents Not Later Than The Submission Of Their Bids. The Procuring Entity Shall Allow The Bidder To Present Its Proof Of Payment For The Fees In Person Or By Facsimile. 6. The Bureau Of Corrections Will Hold A Pre-bid Conference On _january 06, 2025 (01:30pm)__ At Bac Conference Room Nbp Reservation Muntinlupa City, Which Shall Be Open To Prospective Bidders. 7. Bids Must Be Duly Received By The Bac Secretariat Through Manual Submission At The Office Address As Indicated Below, On Or Before __january 20, 2025 (01:30pm)_____. Late Bids Shall Not Be Accepted. 8. All Bids Must Be Accompanied By A Bid Security In Any Of The Acceptable Forms And In The Amount Stated In Itb Clause 15. 9. Bid Opening Shall Be On __january 20, 2025 (01:30pm)____ At The Bac Conference Room Nbp Reservation Muntinlupa City. Bids Will Be Opened In The Presence Of The Bidders’ Representatives Who Choose To Attend The Activity. 10. The Bureau Of Corrections Reserves The Right To Reject Any And All Bids, Declare A Failure Of Bidding, Or Not Award The Contract At Any Time Prior To Contract Award In Accordance With Sections 35.6 And 41 Of The 2016 Revised Implementing Rules And Regulations (irr) Of Ra No. 9184, Without Thereby Incurring Any Liability To The Affected Bidder Or Bidders. 11. For Further Information, Please Refer To: Ma. Adoracion I. Viñas Office Of The Bac Secretariat Supply Office, Bureau Of Corrections, Muntinlupa City Tel # 02-8809-8587/02-8478-0907 Bacsec2022@gmail.com 12. You May Visit The Following Websites: For Downloading Of Bidding Documents: Bucor.gov.ph Date Of Issue: _______________ Ccsupt Celso S Bravo Chairperson, Bids And Awards Committee Section Ii. Instructions To Bidders 1. Scope Of Bid The Procuring Entity, Bureau Of Corrections Invites Bids For The Design And Build Of Bureau Of Corrections Supermaximum Prison Facility (2nd Phase) At Sablayan Prison And Penal Farm (sppf), With Project Identification Number__________________. [note: The Project Identification Number Is Assigned By The Procuring Entity Based On Its Own Coding Scheme And Is Not The Same As The Philgeps Reference Number, Which Is Generated After The Posting Of The Bid Opportunity On The Philgeps Website.] The Procurement Project Design And Build Of Bureau Of Corrections Supermaximum Prison Facility (2nd Phase) At Sablayan Prison And Penal Farm (sppf) Is For The Construction Of Works, As Described In Section Vi (specifications). 2. Funding Information 2.1. The Gop Through The Source Of Funding As Indicated Below For 2025 In The Amount Of Three Hundred Million Pesos Only (₱300,000,000.00). 2.2. The Source Of Funding Is: Nga, The National Expenditure Program 3. Bidding Requirements The Bidding For The Project Shall Be Governed By All The Provisions Of Ra No. 9184 And Its 2016 Revised Irr, Including Its Generic Procurement Manual And Associated Policies, Rules And Regulations As The Primary Source Thereof, While The Herein Clauses Shall Serve As The Secondary Source Thereof. Any Amendments Made To The Irr And Other Gppb Issuances Shall Be Applicable Only To The Ongoing Posting, Advertisement, Or Invitation To Bid By The Bac Through The Issuance Of A Supplemental Or Bid Bulletin. The Bidder, By The Act Of Submitting Its Bid, Shall Be Deemed To Have Inspected The Site, Determined The General Characteristics Of The Contracted Works And The Conditions For This Project, Such As The Location And The Nature Of The Work; (b) Climatic Conditions; (c) Transportation Facilities; (c) Nature And Condition Of The Terrain, Geological Conditions At The Site Communication Facilities, Requirements, Location And Availability Of Construction Aggregates And Other Materials, Labor, Water, Electric Power And Access Roads; And (d) Other Factors That May Affect The Cost, Duration And Execution Or Implementation Of The Contract, Project, Or Work And Examine All Instructions, Forms, Terms, And Project Requirements In The Bidding Documents. 4. Corrupt, Fraudulent, Collusive, Coercive, And Obstructive Practices The Procuring Entity, As Well As The Bidders And Contractors, Shall Observe The Highest Standard Of Ethics During The Procurement And Execution Of The Contract. They Or Through An Agent Shall Not Engage In Corrupt, Fraudulent, Collusive, Coercive, And Obstructive Practices Defined Under Annex “i” Of The 2016 Revised Irr Of Ra No. 9184 Or Other Integrity Violations In Competing For The Project. 5. Eligible Bidders 5.1. Only Bids Of Bidders Found To Be Legally, Technically, And Financially Capable Will Be Evaluated. 5.2. The Bidder Must Have An Experience Of Having Completed A Single Largest Completed Contract (slcc) That Is Similar To This Project, Equivalent To At Least Fifty Percent (50%) Of The Abc Adjusted, If Necessary, By The Bidder To Current Prices Using The Psa’s Cpi, Except Under Conditions Provided For In Section 23.4.2.4 Of The 2016 Revised Irr Of Ra No. 9184. A Contract Is Considered To Be “similar” To The Contract To Be Bid If It Has The Major Categories Of Work Stated In The Bds. 5.3. For Foreign-funded Procurement, The Procuring Entity And The Foreign Government/foreign Or International Financing Institution May Agree On Another Track Record Requirement, As Specified In The Bidding Document Prepared For This Purpose. 5.4. The Bidders Shall Comply With The Eligibility Criteria Under Section 23.4.2 Of The 2016 Irr Of Ra No. 9184. 6. Origin Of Associated Goods There Is No Restriction On The Origin Of Goods Other Than Those Prohibited By A Decision Of The Un Security Council Taken Under Chapter Vii Of The Charter Of The Un. 7. Subcontracts 7.1. The Bidder May Subcontract Portions Of The Project To The Extent Allowed By The Procuring Entity As Stated Herein, But In No Case More Than Fifty Percent (50%) Of The Project. The Procuring Entity Has Prescribed That: A. Subcontracting Is Not Allowed. 7.1. [if Procuring Entity Has Determined That Subcontracting Is Allowed During The Bidding, State:] The Bidder Must Submit Together With Its Bid The Documentary Requirements Of The Subcontractor(s) Complying With The Eligibility Criteria Stated In Itb Clause 5 In Accordance With Section 23.4 Of The 2016 Revised Irr Of Ra No. 9184 Pursuant To Section 23.1 Thereof. 7.2. [if Subcontracting Is Allowed During The Contract Implementation Stage, State:] The Supplier May Identify Its Subcontractor During The Contract Implementation Stage. Subcontractors Identified During The Bidding May Be Changed During The Implementation Of This Contract. Subcontractors Must Submit The Documentary Requirements Under Section 23.1 Of The 2016 Revised Irr Of Ra No. 9184 And Comply With The Eligibility Criteria Specified In Itb Clause 5 To The Implementing Or End-user Unit. 7.3. Subcontracting Of Any Portion Of The Project Does Not Relieve The Contractor Of Any Liability Or Obligation Under The Contract. The Supplier Will Be Responsible For The Acts, Defaults, And Negligence Of Any Subcontractor, Its Agents, Servants, Or Workmen As Fully As If These Were The Contractor’s Own Acts, Defaults, Or Negligence, Or Those Of Its Agents, Servants, Or Workmen. 8. Pre-bid Conference The Procuring Entity Will Hold A Pre-bid Conference For This Project On The Specified Date And Time And Either At Its Physical Address At Bac Conference Room Nbp Reservation Muntinlupa City And/or Through Videoconferencing/webcasting} As Indicated In Paragraph 6 Of The Ib. 9. Clarification And Amendment Of Bidding Documents Prospective Bidders May Request For Clarification On And/or Interpretation Of Any Part Of The Bidding Documents. Such Requests Must Be In Writing And Received By The Procuring Entity, Either At Its Given Address Or Through Electronic Mail Indicated In The Ib, At Least Ten (10) Calendar Days Before The Deadline Set For The Submission And Receipt Of Bids. 10. Documents Comprising The Bid: Eligibility And Technical Components 10.1. The First Envelope Shall Contain The Eligibility And Technical Documents Of The Bid As Specified In Section Ix. Checklist Of Technical And Financial Documents. 10.2. If The Eligibility Requirements Or Statements, The Bids, And All Other Documents For Submission To The Bac Are In Foreign Language Other Than English, It Must Be Accompanied By A Translation In English, Which Shall Be Authenticated By The Appropriate Philippine Foreign Service Establishment, Post, Or The Equivalent Office Having Jurisdiction Over The Foreign Bidder’s Affairs In The Philippines. For Contracting Parties To The Apostille Convention, Only The Translated Documents Shall Be Authenticated Through An Apostille Pursuant To Gppb Resolution No. 13-2019 Dated 23 May 2019. The English Translation Shall Govern, For Purposes Of Interpretation Of The Bid. 10.3. A Valid Pcab License Is Required, And In Case Of Joint Ventures, A Valid Special Pcab License, And Registration For The Type And Cost Of The Contract For This Project. Any Additional Type Of Contractor License Or Permit Shall Be Indicated In The Bds. 10.4. A List Of Contractor’s Key Personnel (e.g., Project Manager, Project Engineers, Materials Engineers, And Foremen) Assigned To The Contract To Be Bid, With Their Complete Qualification And Experience Data Shall Be Provided. These Key Personnel Must Meet The Required Minimum Years Of Experience Set In The Bds. 10.5. A List Of Contractor’s Major Equipment Units, Which Are Owned, Leased, And/or Under Purchase Agreements, Supported By Proof Of Ownership, Certification Of Availability Of Equipment From The Equipment Lessor/vendor For The Duration Of The Project, As The Case May Be, Must Meet The Minimum Requirements For The Contract Set In The Bds. 11. Documents Comprising The Bid: Financial Component 11.1. The Second Bid Envelope Shall Contain The Financial Documents For The Bid As Specified In Section Ix. Checklist Of Technical And Financial Documents. 11.2. Any Bid Exceeding The Abc Indicated In Paragraph 1 Of The Ib Shall Not Be Accepted. 11.3. For Foreign-funded Procurement, A Ceiling May Be Applied To Bid Prices Provided The Conditions Are Met Under Section 31.2 Of The 2016 Revised Irr Of Ra No. 9184. 12. Alternative Bids Bidders Shall Submit Offers That Comply With The Requirements Of The Bidding Documents, Including The Basic Technical Design As Indicated In The Drawings And Specifications. Unless There Is A Value Engineering Clause In The Bds, Alternative Bids Shall Not Be Accepted. 13. Bid Prices All Bid Prices For The Given Scope Of Work In The Project As Awarded Shall Be Considered As Fixed Prices, And Therefore Not Subject To Price Escalation During Contract Implementation, Except Under Extraordinary Circumstances As Determined By The Neda And Approved By The Gppb Pursuant To The Revised Guidelines For Contract Price Escalation Guidelines. 14. Bid And Payment Currencies 14.1. Bid Prices May Be Quoted In The Local Currency Or Tradable Currency Accepted By The Bsp At The Discretion Of The Bidder. However, For Purposes Of Bid Evaluation, Bids Denominated In Foreign Currencies Shall Be Converted To Philippine Currency Based On The Exchange Rate As Published In The Bsp Reference Rate Bulletin On The Day Of The Bid Opening. 14.2. Payment Of The Contract Price Shall Be Made In: A. Philippine Pesos. 15. Bid Security 15.1. The Bidder Shall Submit A Bid Securing Declaration Or Any Form Of Bid Security In The Amount Indicated In The Bds, Which Shall Be Not Less Than The Percentage Of The Abc In Accordance With The Schedule In The Bds. 15.2. The Bid And Bid Security Shall Be Valid Until One Hundred Twenty (120) Calendar Days. Any Bid Not Accompanied By An Acceptable Bid Security Shall Be Rejected By The Procuring Entity As Non-responsive. 16. Sealing And Marking Of Bids Each Bidder Shall Submit One Copy Of The First And Second Components Of Its Bid. The Procuring Entity May Request Additional Hard Copies And/or Electronic Copies Of The Bid. However, Failure Of The Bidders To Comply With The Said Request Shall Not Be A Ground For Disqualification. If The Procuring Entity Allows The Submission Of Bids Through Online Submission To The Given Website Or Any Other Electronic Means, The Bidder Shall Submit An Electronic Copy Of Its Bid, Which Must Be Digitally Signed. An Electronic Copy That Cannot Be Opened Or Is Corrupted Shall Be Considered Non-responsive And, Thus, Automatically Disqualified. 17. Deadline For Submission Of Bids The Bidders Shall Submit On The Specified Date And Time And Either At Its Physical Address Or Through Online Submission As Indicated In Paragraph 7 Of The Ib. 18. Opening And Preliminary Examination Of Bids 18.1. The Bac Shall Open The Bids In Public At The Time, On The Date, And At The Place Specified In Paragraph 9 Of The Ib. The Bidders’ Representatives Who Are Present Shall Sign A Register Evidencing Their Attendance. In Case Videoconferencing, Webcasting Or Other Similar Technologies Will Be Used, Attendance Of Participants Shall Likewise Be Recorded By The Bac Secretariat. In Case The Bids Cannot Be Opened As Scheduled Due To Justifiable Reasons, The Rescheduling Requirements Under Section 29 Of The 2016 Revised Irr Of Ra No. 9184 Shall Prevail. 18.2. The Preliminary Examination Of Bids Shall Be Governed By Section 30 Of The 2016 Revised Irr Of Ra No. 9184. 19. Detailed Evaluation And Comparison Of Bids 19.1. The Procuring Entity’s Bac Shall Immediately Conduct A Detailed Evaluation Of All Bids Rated “passed” Using Non-discretionary Pass/fail Criteria. The Bac Shall Consider The Conditions In The Evaluation Of Bids Under Section 32.2 Of 2016 Revised Irr Of Ra No. 9184. 19.2. If The Project Allows Partial Bids, All Bids And Combinations Of Bids As Indicated In The Bds Shall Be Received By The Same Deadline And Opened And Evaluated Simultaneously So As To Determine The Bid Or Combination Of Bids Offering The Lowest Calculated Cost To The Procuring Entity. Bid Security As Required By Itb Clause 16 Shall Be Submitted For Each Contract (lot) Separately. 19.3. In All Cases, The Nfcc Computation Pursuant To Section 23.4.2.6 Of The 2016 Revised Irr Of Ra No. 9184 Must Be Sufficient For The Total Of The Abcs For All The Lots Participated In By The Prospective Bidder. 20. Post Qualification Within A Non-extendible Period Of Five (5) Calendar Days From Receipt By The Bidder Of The Notice From The Bac That It Submitted The Lowest Calculated Bid, The Bidder Shall Submit Its Latest Income And Business Tax Returns Filed And Paid Through The Bir Electronic Filing And Payment System (efps), And Other Appropriate Licenses And Permits Required By Law And Stated In The Bds. 21. Signing Of The Contract The Documents Required In Section 37.2 Of The 2016 Revised Irr Of Ra No. 9184 Shall Form Part Of The Contract. Additional Contract Documents Are Indicated In The Bds. Section Iii. Bid Data Sheet Bid Data Sheet Itb Clause 5.2 For This Purpose, Contracts Similar To The Project Refer To Contracts Which Have The Same Major Categories Of Work, Which Shall Be: Architectural, Engineering Design, Detailed Engineering Requirements And Construction Of Building With Concreting Works. 7.1 Subcontracting Is Not Allowed 10.3 A Valid Pcab License Is Required, And In Case Of Joint Ventures, A Valid Special Pcab License, And Registration For The Type And Cost Of The Contract For This Project. 10.4 The Key Personnel Must Meet The Required Minimum Years Of Experience Set Below: For Design Personnel: Key Personnel General Experience Relevant Experience Principal Architect The Principal Architect Must Be Duly-licensed With At Least Ten (10) Years’ Experience Experience In The Design Of Residential, Government Offices Or Institutional Facilities, And Shall Preferably Be Knowledgeable In The Application Of Rapid Construction Technologies. Structural Engineer The Structural Engineer Must Be A Duly-licensed Civil Engineer With At Least Ten (10) Years’ Experience. Experience In Structural Design And Shall Preferably Be Knowledgeable In The Application Of Rapid Construction Technologies. Professional Electrical Engineer The Electrical Engineer Must Be A Registered Professional Electrical Engineer With At Least Five (5) Years’ Experience. Experience In The Design Of Lighting, Power Distribution, Communication Systems (specifically Structured And Local Area Network Cabling, Pabx), Building Management Systems And Preferably Knowledgeable In Developments In Emergent Efficient Lighting Technologies And Energy Management. Professional Mechanical Engineer The Mechanical Engineer Must Be A Professional Mechanical Engineer With At Least Five (5) Years’ Experience. Experience In Hvac And Fire Protection Systems And Preferably Knowledgeable In Emergent, Alternative Energy- Efficient Hvac Technologies. Electronics And Communications Engineer The Electronics And Communications Engineer Must Be Duly-licensed With At Least Five (5) Years’ Experience. Experience In The Design Of Communications Systems, And Preferably Knowledgeable In The Application Of Building Automation And Surveillance Systems. Sanitary Engineer The Sanitary Engineer Must Be Duly-licensed With At Least Five (5) Years’ Experience. Experience In The Design Of Building Water Supply And Distribution, Plumbing, And Preferably Knowledgeable In Waste Water Management/treatment, And Emergent, Alternative Effluent Collection And Treatment System. The Design & Build Contractor May, As Needed And At Its Own Expense, Add Additional Professionals And/or Support Personnel For The Optimal Performance Of All Architectural And Engineering Design Services, As Stipulated In These Terms Of Reference, For The Project. Prospective Bidders Shall Attach Each Individual’s Resume And Prc License Of The (professional) Staff. Design Personnel May Also Be Utilized For The Construction Phase Provided That The Same Meet The Minimum Number Of Years Of Experience In The Construction Of Similar Projects. For Construction Personnel: Key Personnel General Experience Relevant Experience Project Manager The Project Manager Shall Be A Licensed Architect Or Engineer With At Least Eight (8) Years Relevant Experience. Relevant Experience On Similar And Comparable Projects In Different Locations. The Project Manager Should Have A Proven Record Or Managerial Capability Through The Directing/managing Of Major Civil Engineering Works, Including Projects Of A Similar Magnitude. Project Architect/engineer The Project Architect/engineer Shall Be A Licensed Architect Or Engineer With At Least Five (5) Years’ Experience. Experience In Similar And Comparable Projects And Shall Preferably Be Knowledgeable In The Application Of Rapid Construction Technologies. Materials Engineer (m.e. I) The Materials Engineer Must Be Duly Accredited With The Dpwh And With At Least Five (5) Years’ Experience. Experience In Similar And Comparable Projects And Shall Preferably Be Knowledgeable In The Application Of Rapid Construction Technologies. Electrical Engineer The Electrical Engineer Must Be Duly-licensed With At Least Five (5) Years’ Experience. Experience In Similar And Comparable Projects In The Installation Of Lighting, Power Distribution, Communication Systems (specifically Structured And Local Area Network Cabling, Pabx), Building Management Systems. Mechanical Engineer The Mechanical Engineer Must Be Duly-licensed With At Least Five (5) Years’ Experience. Experience In Similar And Comparable Projects In The Installation Of Hvac And Fire Protection. Sanitary Engineer The Sanitary Engineer Must Be Duly-licensed With At Least Five (5) Years’ Experience. Experience In Similar And Comparable Projects In The Installation Of Building Water Supply And Distribution, Plumbing. Foreman The Foreman Must Have At Least Five (5) Years’ Experience. Experience In Similar And Comparable Projects And Shall Preferably Be Knowledgeable In The Application Of Rapid Construction Technologies. Safety Officer The Sanitary Officer Must Have At Least Two (2) Years’ Experience. Must Be An Accredited Safety Practitioner By The Department Of Labor And Employment (dole) And Must Have Undergone The Prescribed Forty (40) Hour Construction Safety And Health Training (cosh) 10.5 The Minimum Major Equipment Requirements Are The Following: Equipment Capacity Number Of Units Backhoe At Least 38hp With 0.055 To 0.160 M3 Bucket Capacity 1 Pay Loader At Least 2.5 To 9.5 M3 Bucket Capacity 1 Dump Truck At Least 10 Cu.m. 2 Generator 50kva 1 Concrete Mixers 1 Bagger 4 Welding Machines 300amp Heavy Duty 4 Submersible Dredging Pump At Least 1hp And 2” Output 1 Prospective Bidders Shall Attach The List Of Contractor’s Major Equipment Units, Which Are Owned, Leased, And/or Under Purchase Agreements, Supported By Proof Of Ownership, Certification Of Availability Of Equipment From The Equipment Lessor/vendor For The Duration Of The Project, As The Case May Be. 12 No Further Instructions. 15.1 The Bid Security Shall Be In The Form Of A Bid Securing Declaration Or Any Of The Following Forms And Amounts: A. The Amount Of Not Less Than 2% Of The Abc, If Bid Security Is In Cash, Cashier’s/manager’s Check, Bank Draft/guarantee Or Irrevocable Letter Of Credit; B. The Amount Of Not Less Than 5% Of The Abc, If Bid Security Is In Surety Bond. 19.2 No Further Instructions. 20 Within A Non-extendible Period Of Five (5) Calendar Days From Receipt By The Bidder Of The Notice From The Bac That It Submitted The Lowest Calculated Bid, The Bidder Shall Submit Its; 1. Latest Income And Business Tax Returns Filed And Paid Through The Bir Electronic Filing And Payment System (efps) 2. Supporting Documents For The Slcc (notice Of Award And/or Notice To Proceed And Project Owner’s Certificate Of Final Acceptance Issued By The Owner Other Than The Contractor Or The Constructors Performance Evaluation System (cpes) Final Rating, Which Must Be At Least Satisfactory. In Case Of Contracts With The Private Sector, An Equivalent Document Shall Be Submitted) 3. Certified True Copy Coming From The Issuing Agency Of Valid And Current Registration Certificate (sec Certificate Of Registration For Corporation Or Dti Certificate Of Registration For Sole Proprietorship Or Cda Certificate Of Registration For Cooperative) 4. Valid And Current Mayor’s Or Business Permit 5. Valid And Current Tax Clearance 6. Valid And Current Pcab License And Registration 7. Audited Financial Statement 8. Three (3) Sets Photocopy Of Eligibility And Financial Envelope Duly Marked As “copy No.1”, “copy No.2” And “copy No.3” 21 No Further Instructions. Section Iv. General Conditions Of Contract 1. Scope Of Contract This Contract Shall Include All Such Items, Although Not Specifically Mentioned, That Can Be Reasonably Inferred As Being Required For Its Completion As If Such Items Were Expressly Mentioned Herein. All The Provisions Of Ra No. 9184 And Its 2016 Revised Irr, Including The Generic Procurement Manual, And Associated Issuances, Constitute The Primary Source For The Terms And Conditions Of The Contract, And Thus, Applicable In Contract Implementation. Herein Clauses Shall Serve As The Secondary Source For The Terms And Conditions Of The Contract. This Is Without Prejudice To Sections 74.1 And 74.2 Of The 2016 Revised Irr Of Ra No. 9184 Allowing The Gppb To Amend The Irr, Which Shall Be Applied To All Procurement Activities, The Advertisement, Posting, Or Invitation Of Which Were Issued After The Effectivity Of The Said Amendment. 2. Sectional Completion Of Works If Sectional Completion Is Specified In The Special Conditions Of Contract (scc), References In The Conditions Of Contract To The Works, The Completion Date, And The Intended Completion Date Shall Apply To Any Section Of The Works (other Than References To The Completion Date And Intended Completion Date For The Whole Of The Works). 3. Possession Of Site 3.1 The Procuring Entity Shall Give Possession Of All Or Parts Of The Site To The Contractor Based On The Schedule Of Delivery Indicated In The Scc, Which Corresponds To The Execution Of The Works. If The Contractor Suffers Delay Or Incurs Cost From Failure On The Part Of The Procuring Entity To Give Possession In Accordance With The Terms Of This Clause, The Procuring Entity’s Representative Shall Give The Contractor A Contract Time Extension And Certify Such Sum As Fair To Cover The Cost Incurred, Which Sum Shall Be Paid By Procuring Entity. 3.2 If Possession Of A Portion Is Not Given By The Above Date, The Procuring Entity Will Be Deemed To Have Delayed The Start Of The Relevant Activities. The Resulting Adjustments In Contract Time To Address Such Delay May Be Addressed Through Contract Extension Provided Under Annex “e” Of The 2016 Revised Irr Of Ra No. 9184. 4. The Contractor’s Obligations The Contractor Shall Employ The Key Personnel Named In The Schedule Of Key Personnel Indicating Their Designation, In Accordance With Itb Clause 10.3 And Specified In The Bds, To Carry Out The Supervision Of The Works. The Procuring Entity Will Approve Any Proposed Replacement Of Key Personnel Only If Their Relevant Qualifications And Abilities Are Equal To Or Better Than Those Of The Personnel Listed In The Schedule. 5. Performance Security 5.1. Within Ten (10) Calendar Days From Receipt Of The Notice Of Award From The Procuring Entity But In No Case Later Than The Signing Of The Contract By Both Parties, The Successful Bidder Shall Furnish The Performance Security In Any Of The Forms Prescribed In Section 39 Of The 2016 Revised Irr. 5.2. The Contractor, By Entering Into The Contract With The Procuring Entity, Acknowledges The Right Of The Procuring Entity To Institute Action Pursuant To Ra No. 3688 Against Any Subcontractor Be They An Individual, Firm, Partnership, Corporation, Or Association Supplying The Contractor With Labor, Materials And/or Equipment For The Performance Of This Contract. 6. Site Investigation Reports The Contractor, In Preparing The Bid, Shall Rely On Any Site Investigation Reports Referred To In The Scc Supplemented By Any Information Obtained By The Contractor. 7. Warranty 7.1. In Case The Contractor Fails To Undertake The Repair Works Under Section 62.2.2 Of The 2016 Revised Irr, The Procuring Entity Shall Forfeit Its Performance Security, Subject Its Property (ies) To Attachment Or Garnishment Proceedings, And Perpetually Disqualify It From Participating In Any Public Bidding. All Payables Of The Gop In His Favor Shall Be Offset To Recover The Costs. 7.2. The Warranty Against Structural Defects/failures, Except That Occasioned-on Force Majeure, Shall Cover The Period From The Date Of Issuance Of The Certificate Of Final Acceptance By The Procuring Entity. Specific Duration Of The Warranty Is Found In The Scc. 8. Liability Of The Contractor Subject To Additional Provisions, If Any, Set Forth In The Scc, The Contractor’s Liability Under This Contract Shall Be As Provided By The Laws Of The Republic Of The Philippines. If The Contractor Is A Joint Venture, All Partners To The Joint Venture Shall Be Jointly And Severally Liable To The Procuring Entity. 9. Termination For Other Causes Contract Termination Shall Be Initiated In Case It Is Determined Prima Facie By The Procuring Entity That The Contractor Has Engaged, Before, Or During The Implementation Of The Contract, In Unlawful Deeds And Behaviors Relative To Contract Acquisition And Implementation, Such As, But Not Limited To Corrupt, Fraudulent, Collusive, Coercive, And Obstructive Practices As Stated In Itb Clause 4. 10. Dayworks Subject To The Guidelines On Variation Order In Annex “e” Of The 2016 Revised Irr Of Ra No. 9184, And If Applicable As Indicated In The Scc, The Dayworks Rates In The Contractor’s Bid Shall Be Used For Small Additional Amounts Of Work Only When The Procuring Entity’s Representative Has Given Written Instructions In Advance For Additional Work To Be Paid For In That Way. 11. Program Of Work 11.1. The Contractor Shall Submit To The Procuring Entity’s Representative For Approval The Said Program Of Work Showing The General Methods, Arrangements, Order, And Timing For All The Activities In The Works. The Submissions Of The Program Of Work Are Indicated In The Scc. 11.2. The Contractor Shall Submit To The Procuring Entity’s Representative For Approval An Updated Program Of Work At Intervals No Longer Than The Period Stated In The Scc. If The Contractor Does Not Submit An Updated Program Of Work Within This Period, The Procuring Entity’s Representative May Withhold The Amount Stated In The Scc From The Next Payment Certificate And Continue To Withhold This Amount Until The Next Payment After The Date On Which The Overdue Program Of Work Has Been Submitted. 12. Instructions, Inspections And Audits The Contractor Shall Permit The Gop Or The Procuring Entity To Inspect The Contractor’s Accounts And Records Relating To The Performance Of The Contractor And To Have Them Audited By Auditors Of The Gop Or The Procuring Entity, As May Be Required. 13. Advance Payment The Procuring Entity Shall, Upon A Written Request Of The Contractor Which Shall Be Submitted As A Contract Document, Make An Advance Payment To The Contractor In An Amount Not Exceeding Fifteen Percent (15%) Of The Total Contract Price, To Be Made In Lump Sum, Or At The Most Two Installments According To A Schedule Specified In The Scc, Subject To The Requirements In Annex “e” Of The 2016 Revised Irr Of Ra No. 9184. 14. Progress Payments The Contractor May Submit A Request For Payment For Work Accomplished. Such Requests For Payment Shall Be Verified And Certified By The Procuring Entity’s Representative/project Engineer. Except As Otherwise Stipulated In The Scc, Materials And Equipment Delivered On The Site But Not Completely Put In Place Shall Not Be Included For Payment. 15. Operating And Maintenance Manuals 15.1. If Required, The Contractor Will Provide “as Built” Drawings And/or Operating And Maintenance Manuals As Specified In The Scc. 15.2. If The Contractor Does Not Provide The Drawings And/or Manuals By The Dates Stated Above, Or They Do Not Receive The Procuring Entity’s Representative’s Approval, The Procuring Entity’s Representative May Withhold The Amount Stated In The Scc From Payments Due To The Contractor. Section V. Special Conditions Of Contract Special Conditions Of Contract Gcc Clause 2 Sectional Completion Is Not Applicable The Intended Completion Date Is Three Hundred Sixty-five (365) Calendar Days From The Date Of Receipt Of The Ntp. 4.1 The Procuring Entity Shall Give Possession Of All Parts Of The Site To The Contractor From The Date Of The Receipt Of Notice To Proceed (ntp). 6 No Further Instructions. 7.2 Fifteen (15) Years. 10 No Dayworks Are Applicable To The Contract. 11.1 The Contractor Shall Submit The Program Of Work To The Procuring Entity’s Representative Within Fourteen (14) Calendar Days After The Issuance Of The Notice To Proceed (ntp) 11.2 The Amount To Be Withheld For Late Submission Of An Updated Program Of Work Is One Tenth Of One Percent Of The Total Contract Price. 13 The Amount Of The Advance Payment Is Fifteen Percent (15%) Of The Contract Price Upon Submission To And Acceptance By The Bureau Of Corrections Of An Irrevocable Standby Letter Of Credit Of Equivalent Value From A Commercial Bank, A Bank Guarantee Or A Surety Bond Callable Upon Demand Issued By A Surety Or Insurance Company Duly Licensed By The Insurance Commission And Confirmed By The Bureau Of Corrections. 14 The Contractor May Submit A Request For Payment For Work Accomplished. Such Requests For Payment Shall Be Verified And Certified By The Procuring Entity’s Representative/project Engineer. Materials And Equipment Delivered On The Site But Not Completely Put In Place Shall Not Be Included For Payment. 15.1 The Date By Which “as Built” Drawings Are Required Is Upon Actual Completion Of The Project. 15.2 The Amount To Be Withheld For Failing To Produce “as Built” Drawings And/or Operating And Maintenance Manuals By The Date Required Is Equivalent To Five Percent (5%) Of The Contract Price. Section Vi. Specifications Terms Of Reference Design And Build Of Bureau Of Corrections Supermaximum Prison Facility (2nd Phase) Sablayan Prison And Penal Farm, Occidental Mindoro 1. Project Information 1.1 Project Description The Mission Of The Bucor Is To Protect Society By Confining Offenders In The Controlled Environments Of Prisons And Community-based Facilities That Are Safe, Humane, Cost-efficient, And Appropriately Secure, And That Provide Self-improvement Opportunities To Assist Offenders In Becoming Law-abiding Citizens. The Design And Build Of Bureau Of Corrections Supermaximum Prison Facility (2nd Phase) Shall Be Conducive To The Reformation And Rehabilitation Of Inmates That Will Bring Them Back Into The Mainstream Of Society As Useful Citizens Of The Country. The Contract Will Involve The Design And Build Scheme Leading To The Construction Of The Bureau Of Corrections Super Maximum Prison Facility (2nd Phase) At Sablayan Prison And Penal Farm, Sablayan, Occidental Mindoro. The Plans And Designs Shall Be In Accordance With The Plan Of The Said Structures As Conceptualized By The Bucor Planning And Design Division Or As Conceptualized By The Winning Bidder If The Latter Is Found To Be Superior (as Defined In Section 3.1.1 Of This Tor). Contractors Shall Be Required To Conduct A Bucor Led Site Inspection And Evaluation To Enable The Contractors To Develop Their Proposals Accordingly. The Bureau Of Corrections Shall Not Assume Any Responsibility Regarding Erroneous Interpretations Out Of Any Data Presented By The Contractor. The Bucor Super Maximum Prison Facility (phase 2) Shall Be Constructed As Per Approved Drawings, Specifications, Bill Of Materials, Scope Of Works And The General Contract Conditions Following The Guidelines As Per Annex G Of Irr Of Ra 9184. This Project Aims To Be Completed Within A Year, Aligning With Our Decongestion Program. This Expedited Timeline Underscores Our Commitment To Addressing Urgent Needs Within The Correctional System And Providing Timely Solutions For The High Risk Committed Pdl. The Plans And Designs Shall Be In Accordance With The Plan Of The Said Structures As Conceptualized By The Planning And Design Division (pdd) Under. Contractors Shall Be Required To Conduct A Bucor Led Site Inspection And Evaluation To Enable The Contractors To Develop Their Proposals Accordingly. The Bucor Shall Not Assume Any Responsibility Regarding Erroneous Interpretations Out Of Any Data Presented By The Contractor. The Construction Of Super Maximum-security Facility Shall Be Constructed As Per Approved Drawings, Specifications, Bill Of Materials, Scope Of Works And The General Contract Conditions Following The Guidelines As Per Annex G Of Irr Of Ra 9184. The Project Shall Have The Following Basic Components: A. Complete Detailed Architectural And Engineering Design Plans, Technical Specifications, And Design Calculations For The Construction Of The Project. Such Plans, Designs, And Technical Specifications Shall Be Subject For Review And Approval By The Bucor Pdd. The Design Development And The Contract Documents Phases Of The Design Shall Continue After The Bid Is Awarded. It Shall Likewise Be Subject For Review And Approval By The Director Of Directorate For Engineering Services (des). B. The Bid Shall Be Based On The Conceptual/schematic Design Drawings Prepared By The Bucor Pdd Or That Submitted By The Winning Bidder As Defined In Section 3.1.1 Of This Tor. C. The Contractor Shall Complete The Construction Of The Following Facility Component: I. One (1) Unit 2-storey“type B” Pdl Dormitory At Least 3190 Sq.m (gross Area) Polished Flooring And Sandwich Panel Roofing With The Capacity Of Atleast 340 Pdl, 2 Pdl Per Cell With Double Deck Bunk Bed (160 Cells), 1 Pdl Per Cell With Single Bed (20 Cells). The Dormitory To Include Complete Utilities, Power Supply, Cctv, Water Supply, Fire Protection; • Electrical System: Three-phase Power Line Supply, Connected From The Local Electric Utility (from Main Road/ Source To The Compound. The Power Line Shall Be Used For The Future Development Of The 50 Ha Facility. • Electrical System: Backup Power (three-phase Genset) Supply System With Capacity Not Less Than Total Computed Mva Load, Without Demand Factor (designed To Supply The Dormitory), And To Include Capacitor Bank, If Necessary; • Sewerage And Drainage Systems(pipelines To Cover From Project Site To Nearest Tapping Point); • Water Supply System With Sufficient Pressure To Provide The Water Requirement Of The Psdl. The System Is Oncomposed Of A Cistern Tank, Pumps, And An Overhead Water Storage Tank. Deep Well Source Water System (intake Box, Transmission Pipelines, Pressure Break Tanks, Chlorinator With Tanks And Accessories, Etc.) Whichever Is Deemed Most Suitable For The Facility And Is Authorized By The Lgu. • Fire Protection System (fire & Jockey Pump, Pump House), Fire Detection Alarm System And Fire Suppression Equipment Included In Dormitory. • Cctv Systems: To Install Cctv At Perimeter Fence To Monitor The Inside Compound And Dormitory To Monitor The Hallways And Blind Spots. Ii. 3 Meters Height Concrete Perimeter Security Fence With Concertina Above, To Cover 50 Hectares Area (plastered And Painted Finish); Iii. Primary And Secondary Fence For 1.8 Hectares Compound Including Gates, Catwalk And Post Towers (with Cr And Water Supply) (r.a. 10575 Rule 7). • 4 Meters Height Concrete Primary Perimeter Fence (with Catwalks, Concertina Wirings, Post Tower (with Cr And Water Supply) And Solar Lightings, (ra10575). • Secondary Perimeter Fence (3 Layer Concertina, Steel Mesh) With 300w Integrated Solar Light Every 3 Bays And (to Include Post Towers And Gates); Iv. Road Networks And Culverts • All Entry And Exit Point Of Any Bodies Of Water E.g. Creeks, Canals Shall Be Fenced Culvert By Metal Grills (non-corrosive); • The Project Has An Allocated Budget Sufficient To Cover At Least 1440 Sqm Of Road Construction Within The Prison Facility. While This Budget Allows For Road Development, Prioritization Shall Be Given To The Construction Of Culverts, Both Fenced And Road Culverts, To Ensure Adequate Drainage And Prevent Flooding. These Culverts Are Critical For The Road Leading From The Main Road To The Site, As Well As Along The Perimeter Of The Facility. To Accurately Assess The Project Scope And Design, Bidders Are Required To Conduct A Thorough Site Inspection To Identify And Evaluate All Necessary Culverts." 1.2 Contractual Framework The Contractual Arrangement To Be Used For The Project Is The Design-and-build (db) Scheme. Under This Scheme The Procuring Entity Awards A Single Contract For The Architectural/engineering Design And Construction To A Single Firm, Partnership, Corporation, Joint Venture Or Consortium. The Winning Contractor Shall Consult And Collaborate With The Bucor Pdd For The Preparation Of The Detailed Architectural Design Of The Project. The Detailed Architectural And Engineering Design Shall Be Subject For The Review And Approval By The Bucor Pdd. Contractors Shall Be Required To Conduct A Bucor Led Site Inspection And Evaluation To Enable The Contractors To Develop Their Proposals Accordingly. The Bucor Shall Not Assume Any Responsibility Regarding Erroneous Interpretations Out Of Any Data Presented By The Contractor. The Obligations And Liabilities Of The Contractor And Its Architect Shall Be Joint And Solidary For Purposes Of The Detailed Architectural Design Of The Project In Accordance With Article 1723 Of The Civil Code Of The Philippines And Other Pertinent Laws. The Db Scheme Of Procurement Was Recommended, Endorsed, And Adopted Pursuant To The Annex G Of Irr Of Ra 9184. 2. Scope Of Contract 2.1 Obligations Of The Winning Bidder/contractor A. Render Architectural And Allied Engineering Design Services Including Final Schematic Design Necessary For The Implementation Of The Project. The Allied Engineering Design Services Shall Include, But Shall Not Be Limited To, Design For Architectural, Civil, Structural, Electrical, Mechanical, Plumbing, And Electromechanical. All Drawings Shall Be Generated Using Modern Modeling/drafting Software And Printed On High Quality 20” X 30” Blue Print Paper. B. Undertake Detailed Architectural And Engineering Designs (daeds) Using The Given Data Such As Topographic, Hydrographic And Cross–section Surveys, Geotechnical And Geological Investigation, And Hydrologic Investigation And Initial Schematic Design Or Design Concept Provided By The Bucor Pdd Which Conforms With The Minimum Performance Specifications And Standards (mpss); C. If Applicable, Secure Environmental Clearance Or An “environmental Compliance Certificate (ecc)”. If The Proposed Project Is Considered Outside The Purview Of The Philippine Environmental Impact Statement (eis) System, A Certificate Of Non- Coverage Or Certificate Of Exemption Shall Be Secured. D. The Project Shall Be Constructed According To The Daeds Prepared By The Winning Bidder And Approved By The Bucor And In Compliance With The Mpss As Well As Provided In Rule Vii, Section 7 Of The Irr Of Ra 10575. Likewise, Construction Includes Conformance To The Provisions Pertaining To Buildings Under The Latest Edition Of The Dpwh Standard Specifications For Public Works Structures, Volumes Ii And Iii (blue Book). The Blue Book Prescribes, Among Other Things, The Material Requirements And Construction Requirements For Different Items Of Work, Including The Tests To Be Conducted During Construction By The Dpwh-accredited Testing Laboratory. The Blue Book Incorporates Pertinent Provisions Of The American Society For Testing And Materials (astm) And American Concrete Institute (aci), Among Other Standards, Pertaining To Construction. Attention Shall Be Given To The Relevant Items Of Work In The Following Parts Of The Blue Book: Volume Ii ➢ Part A – Facilities For The Engineer ➢ Part B – Other General Requirements Volume Iii ➢ Part A – Earthwork ➢ Part B – Plain And Reinforced Concrete Works ➢ Part C – Finishing ➢ Part D – Electrical ➢ Part E – Mechanical ➢ Part I – Water Supply ➢ Part J – Flood Control And Drainage ➢ Part I-c – Drainage Works For Materials And Technologies Not Covered By The Blue Book, Or If The Proponent Intends To Use Any New Material/technology Which Is Not Accredited By The Dpwh Bureau Of Research And Standards (brs), The Proponent Shall Submit A Certification From A Recognized Foreign Or International Institution To The Effect That The New Materials Or Technology Meets The Mpss For This Project And Has Been Successfully Used In Existing Structures With Proven Integrity. The Winning Bidder Or Contractor Shall Be Held Liable For Design And Structural Defects And/or Failure Of The Completed Project Within The Warranty Period Specified In Section 62.2 Of The Irr Of Ra 9184; And, F. The Winning Bidder Or Contractor Shall Be Solely Responsible For The Design And Shall Be Held Responsible For Any Default Resulted From Improper Design. Further, Extended Liability Of The Contractor Since It Stipulated That The Works, When Completed, Shall Be Fit For The Purpose For Which It Was Intended As Defined In The Contract. 2.2 Obligations Of The Bucor A. Provide Full Information On All Requirements For The Project; B. Approve The Winning Bidder Or Contractor’s Design Without Diminishing Their Full And Sole Responsibility For The Quality And Integrity Thereof; C. Give Prompt Written Notice Thereof To Winning Bidder Or Contractor, If It Observes Or Becomes Aware Of Any Defect In The Project; D. Designate, When Necessary, Representatives Authorized To Act On Its Behalf. It Shall Examine Documents Submitted By The Winning Bidder Or Contractor And Render Decisions Pertaining Thereto Promptly, To Avoid Unreasonable Delay In The Progress Of Their Work. It Shall Observe The Procedure Of Issuing Orders To The Winning Bidder Or Contractor; E. Supervise And Monitor The Implementation Of The Project; I. Construction Monitoring And Testing Forms: • The Use Of Construction Monitoring And Testing Forms That Will Be Provide By The Bucor - Nhq Pdd Is Mandatory Throughout The Duration Of Construction. • Oversight Of These Forms Will Be Conducted By The Engineering Services (es) Of The Sppf On Behalf Of The Bucor Pdd • Sppf-es To Impose To Contractor Testing Of All Items After Installation And/or Application. Es To Send Pdd Copy Of The Test Report/s. • Sppf-es To Monitor Material Delivery Of Contractor To Ensure All Materials Installed And/or Applied Are In Accordance With The Specifications Stated On Plans And Contract Of This Project. • In Case There Would Be Substitute Or Alternative To The Original Specification Of Material/s, Sppf- Es To Inform Pdd Of Such Variation. Ii. Bucor Engineer Visits: • Nhq Engineers And Architects (personnel Of Pdd) Will Conduct Site Visits On A Quarterly Basis Or Whenever Deemed Necessary To Ensure Compliance With Standards And Regulations. • Pdd Personnel To Witness The Final Testing And Commissioning Of The Systems, Equipment And Utilities Prior To Acceptance Of The Project Or Part Of The Project Thereof. Iii. Progress Billing Payment: • Sppf Es Engineers Will Provide Monthly Updates, Or As Deemed Necessary, On The Statement Of Work Accomplishment Based On The Actual Progress Of The Project, Including Reports Update. F. Pay The Accomplishment Accepted In The Conformance With The Mpss Included Under The Design And Build Contract. I. This Reports And Swa Updates Of The Ippf Es Will Be Reviewed And Approved By Pdd - Nhq Prior To Any Progress Billing Payments Being Made. 2.3 Bidding Documents The Bidding Documents For The Project Shall Govern The Conduct Of The Procurement Of The Project. 3. Scope Of Works 3.1 Planning And Design Phase 3.1.1 Preliminary Architectural Plan (pap) By Bidder The Approved Concept Design Shall Adopt The Provisions Indicated In Rule Vii, Section 7 Of The Irr Of Ra 10575. Bidders Shall Submit Also An Alternative Design Concept With Respect To The Actual Site Condition. This Alternative Design By The Winning Bidder Shall Be Adopted Should The Same Be Found To Be Superior Than The One Conceptualized By The Bucor Pdd. 3.1.2 Detailed Architectural And Engineering Design (daed) By The Winning Bidder During The Implementation Of The Project, The Winning Bidder Shall Prepare The Daed Of The Project And Submit The Same To The Bucor For Approval Prior To The Execution Of The Construction Works. The Winning Bidder Shall Prepare The Daed Based On Its Pap As Reviewed And Accepted By The Bucor Pdd And In Accordance With The Minimum Performance Standards And Specifications (mpss). The Daed Shall Be Undertaken With A Degree Of Accuracy That Will Allow Estimates To Be Made Within Approximately Plus Or Minus Five Percent (+/-5%) Of The Final Quantities. Once Approved By The Bucor, The Winning Bidder’s Daed Shall Form Part Of The Mpss. The Bucor-approved Daed, Together With The Mpss Provisions On Construction Under Section 2.0 Hereof, Shall Govern The Actual Construction Undertaken By The Winning Bidder. The Winning Bidder Shall Undertake The Necessary Field Surveys And Investigation In Accordance With The Dpwh Design Guidelines. In Carrying Out These Works, The Winning Bidder Shall Ensure That The Engineering, Environmental, Particularly During Field Investigations And The Development Of The Preliminary And Final Detailed Engineering Designs. The Winning Bidder Shall Ensure That All Designs Submitted For Approval Have Fully Taken Into Account Key Findings From The Engineering, Environmental, And That Negative Environmental Impacts Have Been Minimized Or Eliminated To The Fullest Extent Possible. 3.1.3 Architectural And Engineering Design Submittals I. Architectural Design A. The Building Should Be Designed With Structural, Electrical, Natural Or Combine Ventilation And Natural Lighting Following Building Design Standards. B. The Prospective Bidder Shall Prepare The Preliminary Architectural Plans In Accordance With The Requirements Of The National Building Code Of The Philippines, Accessibility Law (bp 344) Including All Other Applicable Laws And Local Ordinances. Submittals: (at Suitable Scale On High Quality 20” X 30” Blue Print Paper Minimum Size) 1. Site Development Plan 2. Vicinity Map 3. Perspective 4. Floor Plans 5. Elevations A. Front Elevation B. Rear Elevation C. Right Elevation D. Left Elevation 6. Sections A. Longitudinal Section B. Cross Section 7. Doors & Window Schedule 8. Plans And Details Of Stairs And Ramps 9. Schedule Of Finishes For Floors, Walls And Ceiling 10. Miscellaneous Details Ii. Structural Design A. The Proponent Shall Prepare The Necessary Structural Analysis/calculation And Design Of The Structural Members Of The Building Component In Accordance With The National Building Code Of The Philippines With Its Referral Codes Such As The Latest National Structural Code Of The Philippines. The Design For The Structure Shall Take Into Account, Among Other Things, The Seismic Requirements Of The Area To Determine The Optimum Safety Of The Whole Structure And To Minimize Possible Earthquake Damage. B. On The Basis Of The Data Obtained From The Detailed Site Investigations, Topographical/soil And Survey, Geotechnical Engineering, Foundation Investigation, Material Testing, Survey Of Existing Site Conditions, The Seismic Requirements Of The Area, The Load Requirements Of The Building And Other Investigation Required To Obtain The Data Necessary To Ensure The Safety Of The Structure, The Proposal Shall Prepare The Preliminary Structural Design Plans Of The Structure. Submittals: (at Suitable Scale On High Quality 20” X 30” Blue Print Paper Minimum Size) 1. Structural Design Criteria And Design Notes 2. Foundation Plan 3. Floor Framing Plans 4. Schedule Of Slab, Beams And Girders 5. Schedule Of Columns 6. Schedule Of Footings 7. Structural Details Of Stairs/ramp, If Applicable 8. Roof Framing Plan, If Applicable 9. Schedule And Details Of Trusses, If Applicable 10. Road Design And Details (if Applicable) 11. Miscellaneous Details Iii. Sanitary/plumbing Design A. General • The Detailed Design Shall Conform To The General Standards Adopted By The Sanitary & Plumbing Code Of The Philippines And Other Pertinent Laws And Ordinances. • All Design Considerations/assumptions Shall Be Based On The Results Of The Technical Studies, Detailed Analyses, And Design Computations. • The Technical Drawings And Specifications Shall Clearly Indicate All The Details Required To Ascertain The Care And Thoroughness Devoted In The Preparation Of The Drawings. B. Drainage And Sewerage • The Drainage Layout Shall Show All The Required Information Such As Direction Of Flow, Manhole-to-manhole Distances, And Sizes Of Lines, Manholes/canals, Location Of Outfalls, Etc. • The Prospective Bidder Shall Prepare A Design For The Sewage Treatment Plant In Accordance To The Clean Water Act Of 2004 (republic Act No. 9275) And Other Relevant Laws And Ordinances. Submittals: (at Suitable Scale On High Quality 20” X 30” Blue Print Paper Minimum Size) 1. General Notes 2. Legend & Symbols 3. Sewer, Vent And Storm Drainage Layout 4. Enlarged Toilet Plan For Common And Pwd Toilets 5. Isometric Diagram 6. Miscellaneous Details 7. Drainage And Sewerage System 8. Three Chamber Septic Tank Plans And Details C. Water Supply And Distribution System • The Proponent Shall Carry Out A Preliminary Detailed Design For The Water Supply Of The Project. The Design Should Be On The Basis Of The Source And Volume Of Water Supply, Water Consumption, Piping Network, And Conveyance In Accordance With The Applicable Laws, Rules And Regulations Governing Health, Safety And Sanitation. • The Contractor Shall Install Elevated Water Storage/s Per Unit Located At The Roof Deck Of The Prison Dormitories. (sufficient Capacity To Supply The Pdl) Submittals: (at Suitable Scale On High Quality 20” X 30” Blue Print Paper Minimum Size) 1. General Notes 2. Legend & Symbols 3. Water Line Layout 4. Water Line Isometric Diagram 5. Water Reservoir Plans And Details 6. Miscellaneous Details Iv. Electromechanical Design A. Sewage Treatment Plant • The Prospective Bidder Shall Prepare A Design For The Sewage Treatment Plant In Accordance To The Clean Water Act Of 2004 (republic Act No. 9275) And Other Relevant Laws And Ordinances. Submittals: (at Suitable Scale On High Quality 20” X 30” Blue Print Paper Minimum Size) 1. General Notes 2. Legend & Symbols 3. Electrical System Layout 4. Mechanical System Layout 5. Instrumentation And Control System Diagrams 6. Piping And Instrumentation Diagrams (p&ids) 7. Equipment Details And Specifications 8. Electrical Power Distribution 9. Emergency Power Systems 10. Grounding And Lightning Protection 11. Control And Monitoring Systems, If Applicable 12. Safety Systems 13. Miscellaneous Details B. Fire Protection System • The Prospective Bidder Shall Prepare A Design For The Fire Protection System In Accordance To The Fire Code Of The Philippines, (irr) Of Ra 9514, And Other Relevant Laws And Ordinances. Submittals: (at Suitable Scale On High Quality 20” X 30” Blue Print Paper Minimum Size) 1. Sprinkler System 2. Sprinkler System Isometric Diagram 3. Fire Fighting Piping System Diagram 4. Fire Alarm System Layout 5. Fire Suppression System Layout 6. Smoke Management System Layout 7. Fire Pump And Water Supply 8. Miscellaneous Details V. Electrical Design A. The Prospective Bidder Shall Prepare A Preliminary Design Plan For The Electrical And Power Supply System Of The Building In Accordance With The Electrical Code Of The Philippines, Fire Code Of The Philippines, National Building Code Of The Philippines And Other Relevant Laws And Ordinances. B. The Prospective Bidder Shall Prepare A Design For The Electrical And Power Supply System Considering Ease Of Maintenance And Prevention Of Illegal Connections Including Electrical Supply For Ceiling Fans. C. The Prospective Bidder Shall Prepare A Design For Backup Power Generator With Capacity Not Less Than Total Computed Kva Load Without Demand Factor. D. 3-phase Electrical Supply Shall Be Sourced From The Local Electrical Utility. E. Power Line Connection From Main Source To The Facility Submittals: (at Suitable Scale On High Quality 20” X 30” Blue Print Paper Minimum Size) 1. Power Riser Diagram 2. Power Layout System 3. Lighting Layout System 4. Local Area Network System, If Applicable 5. Grounding System 6. Load Schedules 7. Others As Applicable Vi. Other Requirements Technical Specifications Boring Test Structural Design And Analysis And Computation Final Design And Construction Plans Upon Award Of Contract, The Contractor Shall Comply The Following: O Prepare Final Draft Of Architectural And Engineering Design Plans Incorporating All Design Refinements And Revisions Based On Project Requirement Or As May Be Required By The Bucor Pdd Within The Scope Of Design. O Submit To The Bucor Design And Build Committee (bucor-dbc) The Final Architectural And Engineering Design Plans And Specifications Duly Signed And Sealed By The Concerned Professional Architect, Engineers, Incorporating All The Necessary Revisions And Refinements For Approval By The Head Of Procuring Entity. 3.2 Construction Phase The Following Works Shall Comprise This Phase: I. Permits And Clearances, The Contractor Shall Upon Authorization Of The Head Of The Procuring Entity (hope), Make Representations With The Government Agencies Concerned To Expedite The Processing Of The Necessary Permits And Certificates Such As The Following: A. Zoning Certification And Locational Clearance B. Building /electrical/sanitary Permits C. Certificate Of Occupancy D. Environmental Clearance Certificate E. All Other Permits/clearances As May Be Required For The Construction. Ii. Mobilization, The Contractor Shall Mobilize All The Required Project Team Personnel, Equipment, Tools, And Manpower With The Required Skills And In Sufficient Number As May Be Necessary For His Efficient Undertaking Of The Project. Iii. Clearing, Grubbing And Hauling/disposal Of Debris Iv. Construction Stage As A Rule, Contract Implementation Guidelines For Procurement Of Infrastructure Projects Shall Comply With Annex “e” Of The Revised Irr Of Ra 9184. The Following Provisions Shall Supplement These Procedures: I. No Works Shall Commence Unless The Contractor Has Submitted The Prescribed Documentary Requirements And Implementing Unit Has Given Written Approval. Work Execution Shall Be In Accordance With Reviewed And Approved Documents. Ii. The Contractor Shall Be Responsible For Obtaining All Necessary Information As To Risks, Contingencies And Other Circumstances Which May Affect The Works And Shall Prepare And Submit All Necessary Documents Specified By The Implementing Unit To Meet All Regulatory Approvals As Specified In The Contract Documents. Iii. The Contractor Shall Submit A Detailed Program Of Works Within Fourteen (14) Calendar Days After The Issuance Of The Notice To Proceed (ntp) For Approval By The Head Of The Procuring Entity (hope) That Shall Include, Among Others: A. The Order In Which It Tends To Carry Out The Work Including Anticipated Timing For Each Stage Or Design/detailed Engineering And Construction; B. Periods For Review Of Specific Outputs And Any Other Submissions And Approvals; C. Sequence Of Timing For Inspection And Tests; D. General Description Of The Design And Construction Methods To Be Adopted; E. Number Of Personnel To Be Assigned For Each Stage Of The Work; F. List Of Equipment Required On Site For Each Stage Of The Work; And G. Description Of The Quality Control System To Be Utilized For The Project. Iv. Any Errors, Omissions, Inconsistencies, Inadequate Or Failure Submitted By The Contractor That Do Not Comply With The Requirements Shall Be Rectified, Resubmitted And Reviewed At The Contractor’s Cost. If The Contractor Wishes To Modify Any Design Or Document Which Has Been Previously Submitted, Reviewed And Approved, The Contractor Shall Notify The Implementing Unit Within A Reasonable Period Of Time And Shall Shoulder The Cost Of Such Changes. V. As A Rule, Changes In Design And Construction Requirements Shall Be Limited Only To Those That Have Not Been Anticipated In The Contract Signing And Approval. The Following Guidelines Shall Govern Approval For Change Or Variation Order: A. Change Orders Resulting From Design Errors, Omissions Or Non-conformance With The Performance Specifications And Parameters And The Contract Documents By The Contractor Shall Be Implemented By The Contractor At No Additional Cost To The Bureau Of Corrections. B. Provided That The Contractor Suffers Delay And/or Incurs Costs Due To Changes Or Errors In The Preparation Of Performance Specification And Parameters, The Contractor Shall Be Entitled To Either One Of The Following: An Extension Of Time For Any Such Delays Under Section 10 Of Annex “e” Of Irr-a (ra9184; Or Payments For Such Cost As Specified In The Contract Documents, Provided That The Cumulative Amount Of The Variation Order Does Not Exceed Ten Percent (10%) Of The Original Project Cost. C. The Contract Documents Shall Include The Manner And Schedule Of Payment Specifying The Estimated Contract Amount And Installments In Which The Contract Will Be Paid. D. The Contractor Shall Be Entitled To Advance Payment Subject To The Provisions Of Section 4 Of Annex “e” Of The Revised Irr Of Ra 9184. E. The Implementing Unit Shall Monitor The Quality Control Procedures For The Design And Construction In Accordance With The Government Guidelines And Shall Issue The Proper Certificates Of Acceptance For Sections Of The Works Or Whole Of The Works As Provided For In The Contract Documents. F. The Contractor Shall Provide All Necessary Equipment, Personnel, Instruments, Documents And Others To Carry Out Specified Tests. G. This Design And Build Project Shall Have Minimum Defects Liability Period Of One (1) Year Contract Completion Or As Provided In The Contract Documents. This Is Without Prejudice To The Liabilities Imposed Upon The Engineer/architect Who Drew Up The Plans And Specification For A Building Sanctioned Under Section 1723 Of The New Civil Code Of The Philippines. H. The Contractor Shall Be Held Liable For Design And Structural Defects And/or Failure Of The Completed Project Within The Warranty Period Of 15 Years For Permanent Structures/buildings And 5 Years For Roads As Specified In Section 62.2.2 Of The Revised Irr Of Ra 9184 V. As-built Plans. The Contractor Shall Cause The Preparation And Submission Of As-built Plans Duly Signed And Sealed By All Concerned Parties Involved In The Construction In The Same Sheet Size And Scale As The Original Drawings In One (1) Blue Print Copy And One (1) Reproducible Copy. Vi. General Requirements: 1. Temporary Facilities Such As Field Offices For The Bucor Inspectorate Team, Project Engineers And Quarters For Laborers; Temporary Warehouse For The Construction Material. 2. Office Furniture And Equipment, Survey Equipment And Consumables 3. Photographs: This Item Consists Of The Supply Of Equipment And Materials, I.e., Album, Necessary To Undertake Photographic Progress Activities Of The Project And Of All Cost Incidental To The Preparation And Submission Of Photographs (at Least 12 Photographs Per Day). The Quantities For Photographs Shall Be One (1) Set Of Photographs Per Month. 4. Health And Safety Program Including Personal Protective Equipment (ppe) A. All Standard Safety Measures And Precautions Shall Be Exercised By The Contractor In The Course Of The Project For The Protection Of The Public And Its Workers And In Conformity With Dole Department Order No. 13, Series Of 1998. B. All Workers Shall Be Equipped With Proper Working Uniform And Identification At All Times. They Must Be Registered With The Governing Bucor Security Office And Must Comply With The Bucor’s Rules And Regulations. C. The Contractor Shall Secure His/her Own Equipment And Materials On Site. The Bucor Shall Not Be Liable To Any Losses Incurred During The Progress Of The Work. 5. Minimum Heavy Equipment Requirement (as Needed) For Site Development Such As: No. Item Specification 1. Backhoe 0.8 Cu. M. 2. Backhoe Wheel Mounted With Breaker 0.90 Cu. M. 3. Cargo/service Truck 2-5 Mt., 160 Hp 4. Dump Truck 12 Cu. Yd. 5. Motorized Road Grader G710a, 140hp 6. Payloader 1.5 Cu. M. 7. Vibrator Roller 10 Mt 8. Bulldozer 170 Hp 9. Scraper 515 Hp 10. Truck Mounted Crane, Hydraulic Telescopic Bommer Capacity: 41 – 45 Mt. 11. Crawler Crane 41-45 Mt 12. Generator Set 300 Kw/375 Kva 13. Water Pump 100mm Suction Dia. 14. One Bagger Mixer 4-6 Ft3/min 15. Concrete Vibrator Ey20, 5hp, 32-70mm 16. Vibro Hammer 45000 Kg-m 17. Excavator 17.5 Kw Or Any Specify Types Of Heavy Equipment Needed For A Site Development Will Be Determined By The Winning Bidder. 6. Environmental Compliance 7. Communication Equipment: This Item Consists Of The Provision Of Communication Equipment. 8. Billboard 9. Traffic Management (if Applicable). Vii. Building Construction 1 Lot One (1) Unit 2-storey“type B” Pdl Dormitory At Least 3190 Sq.m (gross Area) Polished Flooring And Sandwich Panel Roofing With The Capacity Of Atleast 340 Pdl, 2 Pdl Per Cell With Double Deck Bunk Bed (160 Cells), 1 Pdl Per Cell With Single Bed (20 Cells). The Dormitory To Include Complete Utilities, Power Supply, Cctv, Water Supply, Fire Protection; • Electrical System: Three-phase Power Line Supply, Connected From The Local Electric Utility (from Main Road/ Source To The Compound. The Power Line Shall Be Used For The Future Development Of The 50 Ha Facility. • Electrical System: Backup Power (three-phase Genset) Supply System With Capacity Not Less Than Total Computed Mva Load, Without Demand Factor (designed To Supply The Dormitory), And To Include Capacitor Bank, If Necessary; • Sewerage And Drainage Systems(pipelines To Cover From Project Site To Nearest Tapping Point); • Water Supply System With Sufficient Pressure To Provide The Water Requirement Of The Psdl. The System Is Composed Of A Cistern Tank, Pumps, And An Overhead Water Storage Tank. Deep Well Source Water System (intake Box, Transmission Pipelines, Pressure Break Tanks, Chlorinator With Tanks And Accessories, Etc.) Whichever Is Deemed Most Suitable For The Facility And Is Authorized By The Lgu. • Fire Protection System (fire & Jockey Pump, Pump House), Fire Detection Alarm System And Fire Suppression Equipment Included In Dormitory. • Cctv Systems: To Install Cctv At Perimeter Fence To Monitor The Inside Compound And Dormitory To Monitor The Hallways And Blind Spots. 1 Lot 3 Meters Height Concrete Perimeter Security Fence With Concertina Above, To Cover 50 Hectares Area (plastered And Painted Finish); 1 Lot Primary And Secondary Fence For 1.8 Hectares Compound Including Gates, Catwalk And Post Towers (with Cr And Water Supply) (r.a. 10575 Rule 7). • 4 Meters Height Concrete Primary Perimeter Fence (with Catwalks, Concertina Wirings, Post Tower (with Cr And Water Supply) And Solar Lightings, (ra10575). • Secondary Perimeter Fence (3 Layer Concertina, Steel Mesh) With 300w Integrated Solar Light Every 3 Bays And (to Include Post Towers And Gates); 1 Lot Road Networks And Culverts • The Project Has An Allocated Budget Sufficient To Cover At Least 1440 Sqm Of Road Construction Within The Prison Facility. While This Budget Allows For Road Development, Prioritization Shall Be Given To The Construction Of Culverts, Both Fenced And Road Culverts, To Ensure Adequate Drainage And Prevent Flooding. These Culverts Are Critical For The Road Leading From The Main Road To The Site, As Well As Along The Perimeter Of The Facility. • All Entry And Exit Point Of Any Bodies Of Water E.g. Creeks, Canals Shall Be Fenced Culvert By Metal Grills (non-corrosive); • To Accurately Assess The Project Scope And Design, Bidders Are Required To Conduct A Thorough Site Inspection To Identify And Evaluate All Necessary Culverts. A. Material Specifications: A. Floor Finishes • Polished Cement Finish Prison Cell, Hallways, Staircases, And Rooms • Plain Cement Finished - Pathways. • Ramps - Anti Slip Pavers Or Tiles • Crs – Unglazed Ceramic Tiles B. Wall Finishes A. Glazed Wall Tiles - 1.8m Height. B. Plain Cement Plaster Finish - For All Buildings And Facilities C. Ceiling Finishes C. Concrete Steel Decking, If Applicable. – Coated In White Enamel D. Painting D. Semi-gloss Solvent Paint Top Coat (high-end Quality) For Interior And Exterior Walls In Two To Three Coats Application. Apply Concrete Neutralizer For Newly Finished Concrete Surfaces. Use Solvent Primer. E. Varnish Paint Finish With Weather Proof Coating – For Doors And Jambs Branded, High-end Quality (offices, Etc.), All Wooden Doors Must Have Secondary Steel Doors. F. Use Epoxy Paint Primer. Epoxy Paint Finish – For Structural Steel And All Metal Works E. Doors And Windows G. No Doors For Prison Facility Comfort Rooms With 1.20 Meter Finish Wall Height (see Rule Vii, Section 7 R-irr Of Ra 10575). H. Steel Doors And Grills – For Dormitories, Gates And Other Security Areas. Sliding Doors For All Cells (see Rule Vii, Section 7 R-irr Of Ra 10575) F. Waterproofing I. Uv Resistant Polyurethane Waterproofing – For All Roof Deck With Topping Works Provided With Welded Wire Mesh. (at Elevated Water Tank Area) J. Cistern - Polyurethane Waterproofing G. Plumbing Works K. Upvc Pipe Series 1000 – For All Soil, Sewer, Waste, Dry And Wet Vent Piping High-end Quality L. Pprc Fusion Type – For All Water Lines High-end Quality M. Contractor Encouraged To Adapt: Lpf Flush Valve For Water Closet Or Stainless Toilet-lavatory Combination. Waterless Urinals N. Sprinkler System To All Prison Dormitories In Accordance With The Provisions Of Revised Plumbing Code Of The Philippines. O. Contractor To Provide A Water System To Supply The Facility 4. Approved Budget For The Contract (abc) The Approved Budget For The Contract (abc) Is Php 300,000,000. This Is The Ceiling For Acceptable Bids. Bids Higher Than Abc Shall Be Automatically Rejected. 5. Proposed Implementation Schedule (example): No. Of Months 1 2 4 5 6 7 8 9 10 11 12 Design Phase Construction Phase 6. Eligibility Criteria For Bidders 6.1 General The Eligibility Requirements For This Design And Build Project Shall Adopt The Provisions Of Annex “g” Of The Implementing Rules And Regulations Of Ra 9184 (e.g. Eligibility Requirement). However, If A Bidder Who Has No Experience In Db Project On Its Own May Opt To Enter A Subcontracting Agreement, Partnership, Or Joint Venture With A Design Or Engineering Firm For The Design Portion Of The Project. 6.2 Legal Requirements A. Valid Contractor’s License Issued By The Philippine Contractor’s Accreditation Board B. Valid License Of The Contractor’s Designer Issued By The Professional Regulation Commission. 6.3 Technical Requirements A. The Contractor’s Designer Must Have Designed One Structure Similar To The Project At Hand With A Construction Cost Of At Least 50 % Of The Abc. 6.4 Financial Requirements The Contractor Must Have A Net Financial Contracting Capacity (nfcc) At Least Equal To The Abc To Be Bid Or Equivalent To Php300,000,000.00. 7. Contents Of The Bid 7.1 In The First Envelope Class “a” Documents Legal Documents I. Philgeps Certificate Of Registration And Membership In Accordance With Section 8.5.2 Of This Irr. For Procurement To Be Performed Overseas, It Shall Be Subject To The Guidelines To Be Issued By The Gppb. (a) Ii. Pcab License And Registration, In Case Of Jv; 57 Iii. Statement Of All Ongoing Government And Private Contracts; Iv. Statement Of Slcc; V. Nfcc Computation; Vi. Jva, If Applicable; Vii. Bid Security In The Prescribed Form, Amount And Validity Period; Viii. Project Requirements, Which Shall Include The Following: 1. Organizational Chart For The Contract To Be Bid; 2. List Of Contractor’s Personnel (design And Construction), To Be Assigned To The Contract To Be Bid, With Their Complete Qualification And Experience Data; 3. List Of Contractor’s Equipment Units Which Are Owned, Leased And/or Under Purchase Agreements, Supported By Certification Of Availability Of Equipment From Lessor/vendor For The Duration Of The Project. Ix. Omnibus Sworn Statement By The Prospective Bidder Or Its Authorized Representative In The Prescribed Format; X. Submission Of Preliminary Conceptual Design Plans: Class “b” Documents I. For Infrastructure Projects, Jv Bidders Shall Submit A Jva In Accordance With R.a. 4566 And It’s Irr. Ii. Each Partner Of The Joint Venture Shall Submit Their Philgeps Certificates Of Registration In Accordance With Section 8.5.2 Of This Irr. The Submission Of Technical And Financial Eligibility Documents By Any Of The Joint Venture Partners Constitutes Compliance: Provided, That The Partner Responsible To Submit The Nfcc Shall Likewise Submit The Statement Of All Of Its Ongoing Contracts And Audited Financial Statements. 1. Preliminary Conceptual Architectural Design Plans In Accordance With The Degree Of Details Specified By The Procuring Entity: (at Suitable Scale On High Quality A3 Blue Print Paper /digital Print Minimum Size) A. Location Plan/vicinity Map B. Perspective C. Floor Plans D. Front View Elevation E. Rear View Elevation F. Left Side View Elevation G. Right Side View Elevation H. Longitudinal Section I. Transverse Section 2. Design And Construction Method 3. List Of Contractor’s Personnel To Be Assigned To The Contract To Be Bid With Their Complete Qualification And Experience Data And Photocopy Of Their Valid Licenses Issued By The Professional Regulatory Commission (prc), Curriculum Vitae Of Key Staff, Partners Or Principal Officers With A Minimum Work Experience Requirements Set In The Bds; For Design The Key Professionals And The Respective Qualifications Of The Design Personnel Shall Be As Follows: • Principal Architect The Principal Architect Must Be Duly-licensed With At Least Ten (10) Years’ Experience In The Design Of Residential, Government Offices Or Institutional Facilities, And Shall Preferably Be Knowledgeable In The Application Of Rapid Construction Technologies. • Structural Engineer The Structural Engineer Must Be A Duly-licensed Civil Engineer With At Least Ten (10) Years’ Experience In Structural Design And Shall Preferably Be Knowledgeable In The Application Of Rapid Construction Technologies. • Professional Electrical Engineer The Electrical Engineer Must Be A Registered Professional Electrical Engineer With At Least Five (5) Years’ Experience In The Design Of Lighting, Power Distribution, Communication Systems (specifically Structured And Local Area Network Cabling, Pabx), Building Management Systems And Preferably Knowledgeable In Developments In Emergent Efficient Lighting Technologies And Energy Management. • Professional Mechanical Engineer The Mechanical Engineer Must Be A Professional Mechanical Engineer With At Least Five (5) Years In Hvac And Fire Protection Systems And Preferably Knowledgeable In Emergent, Alternative Energy- Efficient Hvac Technologies. • Electronics And Communications Engineer The Electronics And Communications Engineer Must Be Duly-licensed With At Least Ten (5) Years’ Experience In The Design Of Communications Systems, And Preferably Knowledgeable In The Application Of Building Automation And Surveillance Systems. • Sanitary Engineer The Sanitary Engineer Must Be Duly-licensed With At Least Five (5) Years’ Experience In The Design Of Building Water Supply And Distribution, Plumbing, And Preferably Knowledgeable In Waste Water Management/treatment, And Emergent, Alternative Effluent Collection And Treatment System. The Design & Build Contractor May, As Needed And At Its Own Expense, Add Additional Professionals And/or Support Personnel For The Optimal Performance Of All Architectural And Engineering Design Services, As Stipulated In These Terms Of Reference, For The Project. Prospective Bidders Shall Attach Each Individual’s Resume And Prc License Of The (professional) Staff. Design Personnel May Also Be Utilized For The Construction Phase Provided That The Same Meet The Minimum Number Of Years Of Experience In The Construction Of Similar Projects. For Construction Personnel The Key Professionals And The Respective Qualifications Of The Construction Personnel Shall Be As Follows: • Project Manager The Project Manager Shall Be A Licensed Architect Or Engineer With At Least Eight (8) Years Relevant Experience On Similar And Comparable Projects In Different Locations. The Project Manager Should Have A Proven Record Or Managerial Capability Through The Directing/managing Of Major Civil Engineering Works, Including Projects Of A Similar Magnitude. • Project Architect/engineer The Project Architect/engineer Shall Be A Licensed Architect Or Engineer With At Least Five (5) Years’ Experience In Similar And Comparable Projects And Shall Preferably Be Knowledgeable In The Application Of Rapid Construction Technologies. • Materials Engineer (m.e. I) The Materials Engineer Must Be Duly Accredited With The Dpwh And With At Least Five (5) Years’ Experience In Similar And Comparable Projects And Shall Preferably Be Knowledgeable In The Application Of Rapid Construction Technologies. • Electrical Engineer The Electrical Engineer Must Be Duly-licensed With At Least Five (5) Years’ Experience In Similar And Comparable Projects In The Installation Of Lighting, Power Distribution, Communication Systems (specifically Structured And Local Area Network Cabling, Pabx), Building Management Systems. • Mechanical Engineer The Mechanical Engineer Must Be Duly-licensed With At Least Five (5) Years’ Experience In Similar And Comparable Projects In The Installation Of Hvac And Fire Protection. • Sanitary Engineer The Sanitary Engineer Must Be Duly-licensed With At Least Five (5) Years’ Experience In Similar And Comparable Projects In The Installation Of Building Water Supply And Distribution, Plumbing. • Foreman The Foreman Must Have At Least Five (5) Years’ Experience In Similar And Comparable Projects And Shall Preferably Be Knowledgeable In The Application Of Rapid Construction Technologies. • Safety Officer The Safety Officer Must Be An Accredited Safety Practitioner By The Department Of Labor And Employment (dole) And Must Have Undergone The Prescribed Forty (40) Hour Construction Safety And Health Training (cosh) And Must Have At Least Two (2) Years’ Experience. 4. Value Engineering Analysis Of Design And Construction. The Second Envelope (financial Proposal) Shall Contain All The Required Documents For Infrastructure Projects Under Section 25.38 Of The Irr Of R.a 9184. 7.2 In The Second Envelope – Financial Proposal The Contents Of Financial Proposal – In The Second Envelope Shall Be Governed By Section 6.1 Design And Build Scheme Of The Dpwh Procurement Manual Volume Ii - Infrastructure Main Guidelines (2016). A. Lump Sum Bid Prices, Which Shall Include The Detailed Engineering Cost, In The Prescribed Bid Form Inclusive Of Vat B. Detailed Estimates Including A Summary Sheet Indicating The Unit Prices Of Construction Materials, Labor Rates And Equipment Rentals Used In Coming Up With The Bid For The Following: I Detailed Architectural And Engineering Design; Ii Demolition Works; And Iii Building Construction/civil Works. C. Bill Of Quantities D. Cash Flow And Payments Schedule. 8. Procedure And Criteria For Bids Evaluation For The Detailed Evaluation Of The Design And Build Proposals A Two-step Procedure Shall Be Adopted By The Bac, Which May Be Undertaken With The Assistance Of The Dbc. First-step Procedure: With The Assistance Of The Bucor Design And Build Committee (bucor-dbc), The Bac Shall Conduct The Opening, Preliminary Examination And Detailed Evaluation Of The Design And Build Proposals, As Follows: (1) The First Step Of The Evaluation Shall Involve The Review Of The Preliminary Conceptual Designs And Track Record Submitted By The Contract As Indicated In The Bidding Documents Using A Nondiscretionary “pass/fail” Criteria That Involve Compliance With The Following Requirements: A. Performance Specifications And Parameters And Degree Of Details; B. Adherence Of Preliminary Design Plans To The Required Concept Of Approach And Methodology For Detailed Engineering, Design And Construction With Emphasis On The Clarity, Feasibility, Innovativeness And Comprehensiveness Of The Plan Approach, And The Quality Of Interpretation Of Project Problems, Risks, And Suggested Solutions; And C. Quality Of Personnel To Be Assigned To The Project Which Covers Suitability Of Key Staff To Perform The Duties Of The Particular Assignments And General Qualifications And Competence Including Education And Training Of The Key Staff. 8.1 Merit Point Critera For The Bid Evaluation 8.1.1 Adherence To Performance Specifications (35 Points) A. Compliance And Adherence To Specifications: Excellent Compliance (100 Points): The Submission Fully Adheres To All Specified Project Requirements And Regulations, Demonstrating Meticulous Attention To Detail And Comprehensive Understanding Of The Tor. All Drawings And Documentation Are Accurate, Complete, And In Compliance With Relevant Standards. Good Compliance (80 Points): The Submission Largely Complies With Project Specifications And Regulations, With Minor Discrepancies. Drawings And Documentation Are Mostly Accurate And Complete, Meeting The Majority Of Requirements. Acceptable Compliance (70 Points): The Submission Satisfies Most Of The Specified Requirements And Regulations, Albeit With Some Notable Omissions Or Inconsistencies. Drawings And Documentation Are Generally Accurate And Complete, Meeting The Basic Expectations. Some Reservations (50 Points): The Submission Partially Meets The Specified Requirements And Regulations, With Several Notable Deficiencies Or Inconsistencies. There Are Significant Gaps Or Inaccuracies In The Drawings And Documentation, Raising Concerns About Compliance. Serious Reservations (20%) The Submission Falls Significantly Short Of Meeting The Specified Requirements And Regulations, With Major Deficiencies Or Inconsistencies. Drawings And Documentation Lack Essential Details Or Fail To Comply With Key Standards, Casting Doubt On The Bidder's Understanding Of The Project Scope. Unacceptable (0%) The Submission Fails To Comply With The Specified Requirements And Regulations, Lacking Essential Details And Demonstrating A Fundamental Misunderstanding Of The Project Scope. Drawings And Documentation Are Incomplete Or Inaccurate, Indicating A Lack Of Capability To Deliver The Project On Time. B. Functionality And Efficiency: Excellent (100%): The Design Optimally Utilizes Space, Facilitating Efficient Accommodation Of 500 Psdl. Layout And Design Enhance Operational Flow, Demonstrating Exceptional Foresight And Planning. Integration Of Facilities Promotes Smooth Prison Management. Good (80%): The Design Effectively Utilizes Space, With Minor Areas For Improvement In Operational Flow. Layout And Design Contribute To Efficient Prison Management, Meeting Most Functional Requirements. Acceptable (70%): The Design Adequately Utilizes Space, Meeting Basic Requirements For Accommodating 500 Psdl. Layout And Design Support Operational Flow, Though Some Improvements Are Needed For Optimal Functionality. Some Reservations (50%): The Design Partially Optimizes Space Utilization, With Notable Deficiencies In Operational Flow. Layout And Design Hinder Efficient Prison Management, Requiring Significant Adjustments For Improvement. Serious Reservations (20%): The Design Inadequately Utilizes Space, Hindering Accommodation Of 500 Psdl. Layout And Design Severely Impede Operational Flow, Indicating A Lack Of Understanding Of Functional Requirements. Unacceptable (0%): The Design Fails To Optimize Space Utilization, Lacking Consideration For Accommodating 500 Psdl. Layout And Design Pose Significant Obstacles To Efficient Prison Management, Indicating A Fundamental Misunderstanding Of Functional Requirements. C. Safety And Security: Excellent (100%): The Design Features Robust Perimeter Walls, Guard Towers, And Security Features Ensuring Optimal Pdl Containment And Facility Security. Fire Protection And Detection Systems Are Highly Reliable, With Comprehensive Safety Measures For Both Psdl And Staff. Good (80%): The Design Incorporates Effective Perimeter Walls, Guard Towers, And Security Features, With Minor Areas For Enhancement. Fire Protection And Detection Systems Are Reliable, With Adequate Safety Measures For Psdl And Staff. Acceptable (70%) The Design Includes Satisfactory Perimeter Walls, Guard Towers, And Security Features, Meeting Basic Requirements For Pdl Containment And Facility Security. Fire Protection And Detection Systems Are Functional, With Sufficient Safety Measures For Psdl And Staff. Some Reservations (50%): The Design Features Partially Effective Perimeter Walls, Guard Towers, And Security Features, With Notable Deficiencies In Pdl Containment And Facility Security. Fire Protection And Detection Systems Lack Reliability, With Limited Safety Measures For Psdl And Staff. Serious Reservations (20%): The Design Lacks Effective Perimeter Walls, Guard Towers, And Security Features, Compromising Pdl Containment And Facility Security. Fire Protection And Detection Systems Are Inadequate, Posing Significant Risks To Psdl And Staff Safety. Unacceptable (0%): The Design Neglects Perimeter Walls, Guard Towers, And Security Features, Failing To Ensure Pdl Containment And Facility Security. Fire Protection And Detection Systems Are Absent Or Non-functional, Posing Severe Risks To Psdl And Staff Safety. D. Sustainability And Environmental Considerations: Excellent (100%): The Design Includes Robust Safety Measures And Emergency Protocols, Ensuring The Safety And Well-being Of Psdl And Staff In Accordance With Ra 10575. Good (80%): The Design Integrates Sustainable Design Principles Effectively, With Minor Opportunities For Improvement In Energy Efficiency And Material Selection. Sewage Treatment And Water Conservation Measures Are Adequate, Supporting Environmental Sustainability. Acceptable (70%) The Design Includes Basic Sustainable Design Principles, Meeting Minimum Requirements For Energy Efficiency And Material Selection. Sewage Treatment And Water Conservation Measures Are Functional, Contributing To Environmental Sustainability. Some Reservations (50%): The Design Partially Incorporates Sustainable Design Principles, With Notable Deficiencies In Energy Efficiency And Material Selection. Sewage Treatment And Water Conservation Measures Lack Comprehensiveness, Limiting Environmental Sustainability. Serious Reservations (20%): The Design Lacks Consideration For Sustainable Design Principles, Neglecting Energy Efficiency And Eco-friendly Materials. Sewage Treatment And Water Conservation Measures Are Insufficient, Undermining Environmental Sustainability. Unacceptable (0%): The Design Disregards Sustainable Design Principles, Showing No Commitment To Energy Efficiency Or Eco-friendly Materials. Sewage Treatment And Water Conservation Measures Are Absent Or Inadequate, Disregarding Environmental Sustainability. E. Aesthetics And Architectural Design: Excellent (100%): The Design Exhibits Exceptional Aesthetic Appeal And Architectural Coherence, Showcasing Innovative And Visually Pleasing Elements. Consideration Of Local Architectural Vernacular And Contextual Integration Is Evident, Contributing To The Overall Excellence Of The Design. Good (80%): The Design Demonstrates Good Aesthetic Appeal And Architectural Coherence, With Some Areas For Enhancement In Creativity And Visual Impact. Consideration Of Local Architectural Vernacular And Contextual Integration Is Apparent, Enriching The Design. Acceptable (70%): The Design Achieves Acceptable Aesthetic Appeal And Architectural Coherence, Meeting Basic Expectations For Visual Presentation. Consideration Of Local Architectural Vernacular And Contextual Integration Is Present, Though Limited In Scope. Some Reservations (50%): The Design Lacks Significant Aesthetic Appeal And Architectural Coherence, With Notable Deficiencies In Creativity And Visual Impact. Consideration Of Local Architectural Vernacular And Contextual Integration Is Minimal, Detracting From The Overall Quality Of The Design. Serious Reservations (20%): The Design Exhibits Poor Aesthetic Appeal And Architectural Coherence, Failing To Engage Visually Or Inspire Interest. Consideration Of Local Architectural Vernacular And Contextual Integration Is Lacking, Diminishing The Design's Relevance And Appropriateness. Unacceptable (0%): The Design Lacks Any Aesthetic Appeal Or Architectural Coherence, Showing No Effort To Engage Visually Or Integrate With The Local Architectural Vernacular. Consideration Of Contextual Integration Is Absent, Rendering The Design Unsuitable For The Project. 8.1.2 Approach And Methodology For Detailed Engineering, Design, And Construction (40 Points) Excellent (100%): The Concept Of Approach And Methodology For Detailed Engineering, Design, And Construction Is Exceptionally Clear, Feasible, Innovative, And Comprehensive. The Plan Demonstrates A High Level Of Understanding Of Project Problems, Risks, And Suggested Solutions, With Well-defined Strategies For Addressing Them. Good (80%): The Concept Of Approach And Methodology For Detailed Engineering, Design, And Construction Is Clear, Feasible, And Comprehensive, With Some Innovative Elements. The Plan Adequately Addresses Project Problems, Risks, And Suggested Solutions, Though Some Areas May Require Further Development. Acceptable (70%): The Concept Of Approach And Methodology For Detailed Engineering, Design, And Construction Satisfactorily Addresses Project Requirements, With A Basic Level Of Clarity And Feasibility. The Plan Outlines Strategies For Addressing Project Problems, Risks, And Suggested Solutions, Meeting The Minimum Expectations. Some Reservations (50%): The Concept Of Approach And Methodology For Detailed Engineering, Design, And Construction Partially Addresses Project Requirements, With Notable Gaps In Clarity And Feasibility. The Plan Lacks Innovative Elements And May Inadequately Address Project Problems, Risks, And Suggested Solutions. Serious Reservations (20%): The Concept Of Approach And Methodology For Detailed Engineering, Design, And Construction Demonstrates Significant Deficiencies In Clarity, Feasibility, And Comprehensiveness. The Plan Fails To Adequately Address Project Problems, Risks, And Suggested Solutions, Indicating A Lack Of Understanding Or Inadequate Planning. Unacceptable (0%): The Concept Of Approach And Methodology For Detailed Engineering, Design, And Construction Is Unclear, Infeasible, And Lacks Comprehensiveness. The Plan Fails To Address Project Problems, Risks, And Suggested Solutions, Indicating A Fundamental Misunderstanding Or Disregard For Project Requirements. 8.1.3 Quality Of Personnel Assigned To The Project (25 Points) Excellent (100%): The Personnel Assigned To The Project, Including Key Staff, Are Highly Suitable And Competent To Perform Their Duties. Key Staff Members Possess Exceptional Qualifications, Competence, Education, And Training Relevant To Their Roles, Demonstrating A High Level Of Expertise And Experience. Good (80%): The Personnel Assigned To The Project, Including Key Staff, Are Suitable And Competent To Perform Their Duties Effectively. Key Staff Members Possess Relevant Qualifications, Competence, Education, And Training, Demonstrating Solid Expertise And Experience. Acceptable (70%): The Personnel Assigned To The Project, Including Key Staff, Meet The Basic Requirements For Suitability And Competence In Performing Their Duties. Key Staff Members Possess General Qualifications And Competence, Education, And Training Relevant To Their Roles, Meeting The Minimum Expectations. Some Reservations (50%): The Personnel Assigned To The Project, Including Key Staff, Demonstrate Some Suitability And Competence In Performing Their Duties, But Notable Deficiencies Are Present. Key Staff Members May Lack Certain Qualifications, Competence, Education, Or Training, Raising Concerns About Their Ability To Effectively Fulfill Their Roles. Serious Reservations (20%): The Personnel Assigned To The Project, Including Key Staff, Exhibit Significant Deficiencies In Suitability And Competence To Perform Their Duties. Key Staff Members Lack Essential Qualifications, Competence, Education, Or Training, Indicating A Lack Of Expertise Or Experience Relevant To Their Roles. Unacceptable (0%): The Personnel Assigned To The Project, Including Key Staff, Are Unsuitable And Incompetent To Perform Their Duties Effectively. Key Staff Members Lack The Necessary Qualifications, Competence, Education, And Training, Demonstrating A Fundamental Mismatch With The Requirements Of Their Roles. 8.2 Determination Of The Merit Point Score The Aggregate Of The Scores In Each Criterion Must Be 70% Or More To Pass Using The Following Formula In Equation. Description Weight (w) Rating (r) Criteria 1 35% (smax/sact) Criteria 2 40% Sact Criteria 3 25% Sact Smax = Η (100) Sact = R1 +r2 +r3 + . . .(rη) Where Η = Number Of Sub Criteria R = Rating Given To The Criteria/sub Criteria The Actual Score (sact) For Each Of The Criteria/sub Criteria Is Obtained By Adding All The Given Rating. (smax) Is The Summation Of Maximum Score Per Criteria 8.3 Passing Rate The Specific Passing Rate Value Depends On The Specific Context Of The Project, The Priorities Of The Design And Build Committee, And The Complexity Of The Requirements Outlined In Ra 10575. Based On The Provided Criteria And Descriptions, The Passing Rate For The Merit Point Criteria (mpc) Could Be Set At 75%. This Means That Bidders Must Score At Least 75% Or Higher In The Evaluation Process To Be Considered As Meeting The Minimum Requirements For The Project A. Pass Rate Per Criteria Will Be Determined Using The Formula: Score = W1*r1 + W2*r2 + W3*r3 B. A Bid Or Technical Bid That Failed In Any Of The Criteria’s Will Not Be Considered For Further Evaluation C. Score Above 75% Will Be Considered As Technically Responsive. Aggregate Score Of Less Than 75% Will Be Considered Failed, And May Be Rejected On That Basis. Second-step Procedure: Only Those Bids That Passed The Above Criteria Shall Be Subjected To The Second Step Of Evaluation. The Bac Shall Open The Financial Proposal Of Each “passed” Bidder And Shall Evaluate It Using Non-discretionary Criteria – Including Arithmetical Corrections For Computational Errors – As Stated In The Bidding Documents, And Thus Determine The Correct Total Calculated Prices. The Bac Shall Automatically Disqualify Any Total Calculated Bid Price Which Exceeds The Abc 9. Data To Be Provided By The Bucor These Data Are For Reference Only And Does Not Guarantee The Contractor That The Data Provided Are Correct, Free From Error, And Applicable To The Project At Hand. The Contractor Is Responsible For The Accuracy Or Applicability Of Any Data That He Will Use In His Design– Build Proposal And Services. Sample Data For Buildings: A. Conceptual Plans 10. Documents To Be Provided By The Contractor During Contract Implementation A. Detailed Architectural And Engineering Plans B. Design Analysis C. Survey Data D. Quantity Calculation E. Detailed Geotechnical Investigation Report F. Design Report. G. As-built Plans, (printed Including Cad Files And Bim Files (lod 500) H. Other Relevant Documents 11. Design And Build Period The Winning Bidder Shall Commence Actual Works Upon The Issuance By The Bucor Of The Notice To Proceed (ntp). The Winning Bidder Shall Complete The Daed And Submit Within The Ninety (60) Calendar Days (cds) Period To The Bucor For Review And Approval. The Contractor Shall Complete The Construction Of The Building Within 305 Cds For The Total Contract Duration Of 365 Cd. Conforme: Name Of Company In Print Signature Over Printed Name Of Authorized Representative/date Section Vii. Drawings The Conceptual Drawings Should Be Attached To This Section Or Annexed In A Separate Folder As Part Of The First Envelope (technical Component Envelope). Preliminary Conceptual Architectural Design Plans In Accordance With The Degree Of Details Specified By The Procuring Entity: At Suitable Scale On High Quality A3 Blue Print Paper /digital Print Minimum Size) 1. Location Plan/vicinity Map 2. Perspective 3. Floor Plans 4. Front View Elevation 5. Rear View Elevation 6. Left Side View Elevation 7. Right Side View Elevation 8. Longitudinal Section 9. Transverse Section Section Viii. Bill Of Quantities The Bill Of Quantities Should Be Attached To This Section As Part Of The Second Envelope (financial Component Envelope). Section Ix. Checklist Of Technical And Financial Documents Checklist Of Technical And Financial Documents I. Technical Component Envelope Class “a” Documents Legal Documents ⬜ (a) Valid Philgeps Registration Certificate (platinum Membership) (all Pages) In Accordance With Section 8.5.2 Of The Irr; Technical Documents ⬜ (b) Statement Of The Prospective Bidder Of All Its Ongoing Government And Private Contracts, Including Contracts Awarded But Not Yet Started, If Any, Whether Similar Or Not Similar In Nature And Complexity To The Contract To Be Bid; And ⬜ (c) Statement Of The Bidder’s Single Largest Completed Contract (slcc) Similar To The Contract To Be Bid, Except Under Conditions Provided Under The Rules; And ⬜ (d) Special Pcab License In Case Of Joint Ventures And Registration For The Type And Cost Of The Contract To Be Bid; And ⬜ (e) Original Copy Of Bid Security. If In The Form Of A Surety Bond, Submit Also A Certification Issued By The Insurance Commission Or Original Copy Of Notarized Bid Securing Declaration; And (f) Project Requirements, Which Shall Include The Following: ⬜ A. Organizational Chart For The Contract To Be Bid; ⬜ B. List Of Contractor’s Key Personnel (e.g., Project Manager, Project Engineers, Materials Engineers, And Foremen), To Be Assigned To The Contract To Be Bid With Their Complete Qualification And Experience Data And Photocopy Of Their Valid Licenses Issued By The Professional Regulatory Commission (prc) And Curriculum Vitae Of Key Staff, Partners Or Principal Officers With A Minimum Work Experience Requirements Set In The Bds; ⬜ C. List Of Contractor’s Major Equipment Units, Which Are Owned, Leased, And/or Under Purchase Agreements, Supported By Proof Of Ownership Or Certification Of Availability Of Equipment From The Equipment Lessor/vendor For The Duration Of The Project, As The Case May Be; And ⬜ (g) Original Duly Signed Omnibus Sworn Statement (oss); And If Applicable, Original Notarized Secretary’s Certificate Or Board Resolution/partnership Resolution In Case Of A Corporation, Partnership, Or Cooperative; Or Original Notarized Special Power Of Attorney In Case Of Sole Proprietorship Of All Members Of The Joint Venture Giving Full Power And Authority To Its Officer To Sign The Oss And Do Acts To Represent The Bidder. And ⬜ (h) Conformity With The Technical Specifications (scope Of Work); And ⬜ (i) Preliminary Conceptual Architectural Design Plans In Accordance With The Degree Of Details Specified By The Procuring Entity: (at Suitable Scale On High Quality A3 Blue Print Paper /digital Print Minimum Size) 1. Location Plan/vicinity Map 2. Perspective 3. Floor Plans 4. Front View Elevation 5. Rear View Elevation 6. Left Side View Elevation 7. Right Side View Elevation 8. Longitudinal Section 9. Transverse Section ⬜ (j) Design And Construction Method And ⬜ (k) Value Engineering Analysis Of The Design And Construction Method. And Financial Documents ⬜ (l) The Prospective Bidder’s Computation Of Net Financial Contracting Capacity (nfcc) At Least Equal To The Abc. And Class “b” Documents ⬜ (m) Jv Bidders Shall Submit A Jva In Accordance With R.a. 4566 And Its Irr. Each Partner Of The Joint Venture Shall Submit Their Respective Philgeps Certificates Of Registration In Accordance With Section 8.5.2 Of This Irr. The Submission Of Technical And Financial Eligibility Documents By Any Of The Joint Venture Partners Constitutes Compliance: Provided, That The Partner Responsible To Submit The Nfcc Shall Likewise Submit The Statement Of All Of Its Ongoing Contracts And Audited Financial Statements. Ii. Financial Component Envelope ⬜ (n) Original Of Duly Signed And Accomplished Financial Bid Form; And Other Documentary Requirements Under Ra No. 9184 ⬜ (o) Original Of Duly Signed Bid Prices In The Bill Of Quantities; And ⬜ (p) Duly Accomplished Detailed Estimates Form, Including A Summary Sheet Indicating The Unit Prices Of Construction Materials, Labor Rates, And Equipment Rentals Used In Coming Up With The Bid; And ⬜ (q) Cash Flow And Payment Schedule. Bidding Form Company Letterhead Statement Of Ongoing Government & Private Contracts Design And Build Of Bureau Of Corrections Supermaximum Prison Facility (2nd Phase) At Sablayan Prison And Penal Farm (sppf) Statement Of All Its Ongoing Government And Or Private Contracts Including Contracts Awarded But Not Yet Started, If Any Whether Similar Or Not Similar In Nature. Name Of Contract Date Of Contract Contract Duration Owner’s Name And Address Nature Of Work Contractor’s Role (whether Sole Contractor, Subcontractor, Or Partner In A Jv) And Percentage Of Participation Total Contract Value At Award Date Of Completion Or Estimated Completion Time Value Of Outstanding Works Certified Correct: Name And Signature Of Authorized Representative Position Date Company Letterhead Statement Of Single Largest Completed Contract Design And Build Of Bureau Of Corrections Supermaximum Prison Facility (2nd Phase) At Sablayan Prison And Penal Farm (sppf) Statement Of Single (1) Largest Completed Contract Of Similar In Nature Within The Last Six (6) Years From The Date Of Submission And Receipt Of Bids Amounting To At Least Fifty Percent (50%) Of The Approved Budget Of The Contract (abc) Name Of Contract Date Of Contract Contract Duration Owner’s Name And Address Nature Of Work Contractor’s Role (whether Sole Contractor, Subcontractor, Or Partner In A Jv) And Percentage Of Participation Total Contract Value At Award Amount Of Completed Contracts, Adjusted By The Bidder To Current Prices Using Psa’s Consumer Price Index, If Necessary Date Of Completion Or Estimated Completion Time Certified Correct: Name And Signature Of Authorized Representative Position Date Company Letterhead Design And Build Of Bureau Of Corrections Supermaximum Prison Facility (2nd Phase) At Sablayan Prison And Penal Farm (sppf) Republic Of The Philippines) City Of _______________________) S.s. X------------------------------------------------------x Bid Securing Declaration Invitation To Bid: [insert Reference Number] To: Bureau Of Corrections I/we, The Undersigned, Declare That: 1. I/we Understand That, According To Your Conditions, Bids Must Be Supported By A Bid Security, Which May Be In The Form Of A Bid-securing Declaration. 2. I/we Accept That: (a) I/we Will Be Automatically Disqualified From Bidding For Any Contract With Any Procuring Entity For A Period Of Two (2) Years Upon Receipt Of Your Blacklisting Order; And, (b) I/we Will Pay The Applicable Fine Provided Under Section 6 Of The Guidelines On The Use Of Bid Securing Declaration, Within Fifteen (15) Days From Receipt Of The Written Demand By The Procuring Entity For The Commission Of Acts Resulting To The Enforcement Of The Bid Securing Declaration Under Sections 23.1(b), 34.2, 40.1 And 69.1, Except 69.1(f), Of The Irr Of Ra 9184; Without Prejudice To Other Legal Action The Government May Undertake. 3. I/we Understand That This Bid Securing Declaration Shall Cease To Be Valid On The Following Circumstances: (a) Upon Expiration Of The Bid Validity Period, Or Any Extension Thereof Pursuant To Your Request; (b) I Am/we Are Declared Ineligible Or Post-disqualified Upon Receipt Of Your Notice To Such Effect, And (i) I/we Failed To Timely File A Request For Reconsideration Or (ii) I/we Filed A Waiver To Avail Of Said Right; (c) I Am/we Are Declared The Bidder With The Lowest Calculated Responsive Bid, And I/we Have Furnished The Performance Security And Signed The Contract. In Witness Whereof, I/we Have Hereunto Set My/our Hand/s This ____ Day Of [month] [year] At [place Of Execution]. ______________________________________________________ [insert Name Of Bidder’s Authorized Representative] _____________________________ [insert Signatory’s Legal Capacity] Affiant Subscribed And Sworn To Before Me This ___ Day Of [month] [year] At [place Of Execution], Philippines. Affiant/s Is/are Personally Known To Me And Was/were Identified By Me Through Competent Evidence Of Identity As Defined In The 2004 Rules On Notarial Practice (a.m. No. 02-8-13-sc). Affiant/s Exhibited To Me His/her [insert Type Of Government Identification Card Used], With His/her Photograph And Signature Appearing Thereon, With No. ____________ Issued On ______________ At ___________________________________. Witness My Hand And Seal This ___ Day Of [month] [year]. Name Of Notary Public Serial No. Of Commission _______________ Notary Public For _______ Until __________ Roll Of Attorneys No. __________________ Ptr No. ______ [date Issued], [place Issued] Ibp No. ______ [date Issued], [place Issued Doc. No. _____ Page No. _____ Book No. _____ Series Of ____ Company Letterhead Omnibus Sworn Statement Design And Build Of Bureau Of Corrections Supermaximum Prison Facility (2nd Phase) At Sablayan Prison And Penal Farm (sppf) _________________________________________________________________________ Republic Of The Philippines ) City/municipality Of ______ ) S.s. Affidavit I, [name Of Affiant], Of Legal Age, [civil Status], [nationality], And Residing At [address Of Affiant], After Having Been Duly Sworn In Accordance With Law, Do Hereby Depose And State That: 1. [select One, Delete The Other:] [if A Sole Proprietorship:] I Am The Sole Proprietor Or Authorized Representative Of [name Of Bidder] With Office Address At [address Of Bidder]; [if A Partnership, Corporation, Cooperative, Or Joint Venture:] I Am The Duly Authorized And Designated Representative Of [name Of Bidder] With Office Address At [address Of Bidder]; 2. [select One, Delete The Other:] [if A Sole Proprietorship:] As The Owner And Sole Proprietor, Or Authorized Representative Of [name Of Bidder], I Have Full Power And Authority To Do, Execute And Perform Any And All Acts Necessary To Participate, Submit The Bid, And To Sign And Execute The Ensuing Contract For Design And Build Of Bureau Of Corrections Supermaximum Prison Facility (2nd Phase) Of The Bureau Of Corrections, As Shown In The Attached Duly Notarized Special Power Of Attorney; [if A Partnership, Corporation, Cooperative, Or Joint Venture:] I Am Granted Full Power And Authority To Do, Execute And Perform Any And All Acts Necessary To Participate, Submit The Bid, And To Sign And Execute The Ensuing Contract For Design And Build Of Bureau Of Corrections Supermaximum Prison Facility (2nd Phase) Of The Bureau Of Corrections, As Shown In The Attached [state Title Of Attached Document Showing Proof Of Authorization (e.g., Duly Notarized Secretary’s Certificate, Board/partnership Resolution, Or Special Power Of Attorney, Whichever Is Applicable;)]; 3. [name Of Bidder] Is Not “blacklisted” Or Barred From Bidding By The Government Of The Philippines Or Any Of Its Agencies, Offices, Corporations, Or Local Government Units, Foreign Government/foreign Or International Financing Institution Whose Blacklisting Rules Have Been Recognized By The Government Procurement Policy Board, By Itself Or By Relation, Membership, Association, Affiliation, Or Controlling Interest With Another Blacklisted Person Or Entity As Defined And Provided For In The Uniform Guidelines On Blacklisting; 4. Each Of The Documents Submitted In Satisfaction Of The Bidding Requirements Is An Authentic Copy Of The Original, Complete, And All Statements And Information Provided Therein Are True And Correct; 5. [name Of Bidder] Is Authorizing The Head Of The Procuring Entity Or Its Duly Authorized Representative(s) To Verify All The Documents Submitted; 6. [select One, Delete The Rest:] [if A Sole Proprietorship:] The Owner Or Sole Proprietor Is Not Related To The Head Of The Procuring Entity, Members Of The Bids And Awards Committee (bac), The Technical Working Group, And The Bac Secretariat, The Head Of The Project Management Office Or The End-user Unit, And The Project Consultants By Consanguinity Or Affinity Up To The Third Civil Degree; [if A Partnership Or Cooperative:] None Of The Officers And Members Of [name Of Bidder] Is Related To The Head Of The Procuring Entity, Members Of The Bids And Awards Committee (bac), The Technical Working Group, And The Bac Secretariat, The Head Of The Project Management Office Or The End-user Unit, And The Project Consultants By Consanguinity Or Affinity Up To The Third Civil Degree; [if A Corporation Or Joint Venture:] None Of The Officers, Directors, And Controlling Stockholders Of [name Of Bidder] Is Related To The Head Of The Procuring Entity, Members Of The Bids And Awards Committee (bac), The Technical Working Group, And The Bac Secretariat, The Head Of The Project Management Office Or The End-user Unit, And The Project Consultants By Consanguinity Or Affinity Up To The Third Civil Degree; 7. [name Of Bidder] Complies With Existing Labor Laws And Standards; And 8. [name Of Bidder] Is Aware Of And Has Undertaken The Responsibilities As A Bidder In Compliance With The Philippine Bidding Documents, Which Includes: A. Carefully Examining All Of The Bidding Documents; B. Acknowledging All Conditions, Local Or Otherwise, Affecting The Implementation Of The Contract; C. Making An Estimate Of The Facilities Available And Needed For The Contract To Be Bid, If Any; And D. Inquiring Or Securing Supplemental/bid Bulletin(s) Issued For The Design And Build Of Bureau Of Corrections Supermaximum Prison Facility (2nd Phase). 9. [name Of Bidder] Did Not Give Or Pay Directly Or Indirectly, Any Commission, Amount, Fee, Or Any Form Of Consideration, Pecuniary Or Otherwise, To Any Person Or Official, Personnel Or Representative Of The Government In Relation To Any Procurement Project Or Activity. 10. In Case Advance Payment Was Made Or Given, Failure To Perform Or Deliver Any Of The Obligations And Undertakings In The Contract Shall Be Sufficient Grounds To Constitute Criminal Liability For Swindling (estafa) Or The Commission Of Fraud With Unfaithfulness Or Abuse Of Confidence Through Misappropriating Or Converting Any Payment Received By A Person Or Entity Under An Obligation Involving The Duty To Deliver Certain Goods Or Services, To The Prejudice Of The Public And The Government Of The Philippines Pursuant To Article 315 Of Act No. 3815 S. 1930, As Amended, Or The Revised Penal Code. In Witness Whereof, I Have Hereunto Set My Hand This __ Day Of ___, 2024 At ____________, Philippines. _____________________________________ Bidder’s Representative/authorized Signatory Affiant Subscribed And Sworn To Before Me This ___ Day Of [month] [year] At [place Of Execution], Philippines. Affiant/s Is/are Personally Known To Me And Was/were Identified By Me Through Competent Evidence Of Identity As Defined In The 2004 Rules On Notarial Practice (a.m. No. 02-8-13-sc). Affiant/s Exhibited To Me His/her [insert Type Of Government Identification Card Used], With His/her Photograph And Signature Appearing Thereon, With No. ____________ And Issued On ____________________ At _____________________. Witness My Hand And Seal This ___ Day Of [month] [year]. Name Of Notary Public Serial No. Of Commission _______________ Notary Public For _______ Until __________ Roll Of Attorneys No. __________________ Ptr No. ______ [date Issued], [place Issued] Ibp No. ______ [date Issued], [place Issued] Doc. No. _____ Page No. _____ Book No. _____ Series Of _____ Company Letterhead Certificate Of Net Financial Contracting Capacity Design And Build Of Bureau Of Corrections Supermaximum Prison Facility (2nd Phase) At Sablayan Prison And Penal Farm (sppf) (please Show Figures At How You Arrived At The Nfcc) This Is To Certify That Our Net Financial Contracting Capacity (nfcc) Is _____________________ (p____________) Which Is At Least Equal To The Total Ceiling Price We Are Bidding. The Amount Is Computed As Follows: (please Show Computation Of Nfcc) Nfcc = (ca-cl) (15) – C Where: Ca = Current Assets Cl = Current Liabilities C = Value Of All Outstanding Or Uncompleted Portions Of The Projects Under Going Contracts, Including Awarded Contracts Yet To Be Started Coinciding With The Contract For This Project Note: The Values Of The Bidder’s Current Assets And Current Liabilities Shall Be Based On The Audited Financial Statement Submitted To The Bir. Issued This _________________day Of ________________, 2024 _______________________________________________ Name & Signature Of Authorized Representative ____________________ Position _______________ Date Company Letterhead Bid Form Date: Ib No: To Bids And Awards Committee Bureau Of Corrections Nbp Reservation Muntinlupa City We, The Undersigned, Declare That: (a) We Have Examined And Have No Reservation To The Bidding Documents, Including Addenda, For The Contract Design And Build Of Bureau Of Corrections Supermaximum Prison Facility (2nd Phase) At Sablayan Prison And Penal Farm (sppf) (b) We Offer To Execute The Works For This Contract In Accordance With The Bid And Bid Data Sheet, General And Special Conditions Of Contract Accompanying This Bid; The Total Price Of Our Bid, Excluding Any Discounts Offered Below Is: ________________________________________₱_________________; The Discounts Offered And The Methodology For Their Application Are: [insert Information]; (c) Our Bid Shall Be Valid For A Period Of 120 Calendar Days From The Date Fixed For The Bid Submission Deadline In Accordance With The Bidding Documents, And It Shall Remain Binding Upon Us And May Be Accepted At Any Time Before The Expiration Of That Period; (d) If Our Bid Is Accepted, We Commit To Obtain A Performance Security In The Amount Of 30% Percent Of The Contract Price For The Due Performance Of The Contract; (e) Our Firm, Including Any Subcontractors Or Suppliers For Any Part Of The Contract, Have Nationalities From The Following Eligible Countries; (f) We Are Not Participating, As Bidders, In More Than One Bid In This Bidding Process, Other Than Alternative Offers In Accordance With The Bidding Documents; (g) Our Firm, Its Affiliates Or Subsidiaries, Including Any Subcontractors Or Suppliers For Any Part Of The Contract, Has Not Been Declared Ineligible By The Funding Source; (h) We Understand That This Bid, Together With Your Written Acceptance Thereof Included In Your Notification Of Award, Shall Constitute A Binding Contract Between Us, Until A Formal Contract Is Prepared And Executed; And (i) We Understand That You Are Not Bound To Accept The Lowest Calculated Bid Or Any Other Bid That You May Receive. (j) We Likewise Certify/confirm That The Undersigned, Is The Duly Authorized Representative Of The Bidder, And Granted Full Power And Authority To Do, Execute And Perform Any And All Acts Necessary To Participate, Submit The Bid, And To Sign And Execute The Ensuing Contract For The Design And Build Of Bureau Of Corrections Supermaximum Prison Facility (2nd Phase) Of The Bureau Of Corrections. (k) We Acknowledge That Failure To Sign Each And Every Page Of This Bid Form, Including The Bill Of Quantities, Shall Be A Ground For The Rejection Of Our Bid. Name: In The Capacity Of: Signed: Duly Authorized To Sign The Bid For And On Behalf Of: Date: ___________
Closing Date20 Jan 2025
Tender AmountPHP 300 Million (USD 5.1 Million)
VETERANS AFFAIRS, DEPARTMENT OF USA Tender
Civil And Construction...+3Building Construction, Consultancy Services, Civil And Architectural Services
United States
Details: This Is Not A Request For Proposal. This Is A Request For Standard Form (sf) 330 Architect-engineer Qualifications Packages Only. All Information Needed To Submit Sf 330 Documents Is Contained Herein. No Solicitation Package, Technical Information, Or Bidder/plan Holder List Will Be Issued. The Government Will Not Pay, Nor Reimburse, Any Costs Associated With Responding To This Request. The Government Is Under No Obligation To Award A Contract As A Result Of This Announcement. 1. General Information Veterans Health Administration (vha) Program Contracting Activity Central (pcac) Is Seeking Sources And Intends To Award A Firm Fixed Price Design Contract For Architect-engineering (a-e) Services For The Development Of Complete Construction Documents, Which Include Working Drawings, Specifications, And Reports, And Construction Period Services For Project #676-336 Fire Station Design-tomah Va Medical Center. The A-e Services Contract That Is Anticipated To Be Awarded Will Be Procured In Accordance With The Selection Of Architects And Engineers Statute [formerly Known As The Brooks Architect Engineer Act], Federal Acquisition Regulation (far) Subpart 36.6 Architectural And Engineering Services, Va Acquisition Regulation (vaar) 836.6, And Va Acquisition Manual (vaam) M836.6 Architect-engineer Services. In Accordance With Far 36.209, Construction Contracts With Architect-engineer Firms, No Contract For The Construction Of A Project Shall Be Awarded To The Firm That Designed The Project Or Its Subsidiaries Or Affiliates, Except With The Approval Of The Head Of The Agency Or Authorized Representative. 2. Project Information This Project Is A 100% Set-aside For Service-disabled Veteran-owned Small Business (sdvosb) Concerns. The Naics Code For This Procurement Is 541330 Engineering Services And The Annual Small Business Size Standard Is $25.5m. A Full Design Team Is Required To Complete This Project. The Va Expects To Award The Anticipated A-e Contract By Late March 2025. The Anticipated Period Of Performance For Completion Of Design Is 160 Calendar Days After Notice Of Award (noa). The Vaar Magnitude Of Construction Is Between $5,000,000 And $10,000,000. Please Note That The 160-calendar-day Period Of Performance For The Design Completion Begins With The Issuance Of The Noa And That A Notice To Proceed (ntp) Will Not Be Issued For The Completion Of A Design Project. 3. A-e Selection Process Firms Submitting Sf 330s In Response To This Announcement, Not Later Than The Closing Date And Time Specified Herein And In Accordance With Submission Requirements, Will Be Considered For Evaluation. The Selection Will Be Made As Follows: Sf 330s Will Be Evaluated In Accordance With The Primary Selection Criteria As Stated In This Pre-solicitation Notice. These Evaluations Will Determine The Most Highly Qualified Firms For This Particular Requirement. In Accordance With Far 36.602-3(c), At Least Three Of The Most Highly Qualified Firms Will Then Be Notified Of The Government S Intent To Hold Discussions. All Firms Not Invited To Participate In Discussions Will Be Notified At This Time. In Accordance With Far 36.607(b), Any Requested Debriefings Of Successful And Unsuccessful Firms Will Be Held After Final Selection Has Taken Place And Will Be Conducted, To The Extent Practicable, In Accordance With 15.503, 15.506(b) Through (f), And 15.507(c). Note That 15.506(d)(2) Through (d)(5) Do Not Apply To Architect-engineer Contracts. Discussions Will Be Held With The Most Highly Qualified Firms In The Form Of Written Responses. The Firms Invited To Participate In Discussions Will Be Notified By Email And Provided Further Instructions, Including Any Questions Or Topics To Address. Following The Completion Of Discussions, The Firms Will Be Evaluated And Ranked Based On The Primary And (if Necessary) Secondary Selection Criteria. The Final Evaluation And Ranking Will Consider The Sf 330 Submission For Each Firm, As Well As Additional Information Obtained Via Discussions. The Highest Rated Firm Will Be Selected To Receive The Solicitation And Engage In Negotiations. The Solicitation Will Be Issued To The Highest Rated Firm As A Request For Fee Proposal (rfp). All Sow Attachments And Site-specific Documentation Will Be Provided To The Highest Rated Firm With The Rfp. A Site Visit Will Be Authorized During The Negotiation Process. An Award Will Then Be Made As Long As The Negotiation Of Rates And Hours Leads To A Fair And Reasonable Determination Of The Final Contract Price. If Negotiations With The Highest Rated Firm Are Unsuccessful, The Firm Will Be Notified That Negotiations Have Been Terminated. Negotiations Will Then Be Initiated With The Next Highest Rated Firm, And So On Until Award Can Be Made. 4. Selection Criteria: Firms Responding To This Notice Will Be Evaluated And Ranked Using The Primary And Secondary Selection Criteria Listed Below. The Factors Are Listed In Descending Order Of Importance. The Evaluation Will Consider How Each Factor Is Addressed And How It Is Formatted To Coincide With The Selection Criteria. Primary Selection Criteria: Professional Qualifications: Professional Qualifications Necessary For Satisfactory Performance Of Required Service. The A-e Shall Demonstrate They Are Able To Sign And Stamp Each Drawing By Individuals Licensed In Any State In The United States For The Key Positions Listed Below. Provide Professional License Numbers And/or Proof Of Licensure. The Evaluation Shall Consider The Specific Experience (minimum Of Five Years) And Qualifications (i.e., Education, Training, Registration, Certifications, Overall Relevant Experience, And Longevity With The Firm As Full-time Employees) Of Personnel Proposed For Assignment To The Project. The Lead Designer In Each Discipline Must Be Registered But Does Not Have To Be Registered In The Particular State Where The Project Is Located. Disciplines Requiring A Florida License Include Civil/structural And Hazardous Material Abatement/industrial Hygiene. A Resume For Each Of These Key Positions Must Be Provided In Section E Of The Sf330. Key Positions And Disciplines Required For This Project Include, But Are Not Limited To: Architect (leed Certification/us Green Build Council Certification) Cost Estimator Civil Engineer Electrical Engineer Environmental Engineer Fire Protection Engineer Mechanical Engineer Plumbing Engineer Project Manager Quality Assurance Manager Structural Engineer Physical Security Specialists Commissioning Agent Offeror Must Include The Following Statement Of Sdvosb Compliance When Submitting The Personnel Proposed To Perform The Work Under This Requirement: I, [signatory Authority], Of [company Name], Certify That The Sdvosb Prime Contractor Will Not Pay More Than 50% Of The Amount Paid By The Government To The Prime For Contract Performance To Firms That Are Not Certified Sdvosbs Listed In The Sba Certification Database In Compliance With Vaar 852.219-73. The Information Provided In Sections C Through E Of The Sf 330 Will Be Used To Evaluate This Factor. Do Not Include This Information In Section H Unless It Is Pertinent To Support The Information Listed In The Other Sections. Specialized Experience And Technical Competence: Specialized Experience And Technical Competence In The Design And Construction Period Services Shall Be Provided For Network Infrastructure Installation, Renovations, Or Upgrades. Projects Experience Should Include Upgrading Large Scale (multi-building With Multiple Generational Oit Systems) Fiber Optics, Data Cable, Structured Cabling, Electrical Distribution Design, Electrical Upgrades, Uninterruptable Power Systems (ups), Electrical Bonding, Building Management Systems/building Automation Systems (bms/bas), Hvac, It Room Renovations/expansion/relocations, Data Centers/server Rooms Reconfiguration, And Physical Security Upgrades, Duct Bank And Direct Boring Operations. Other Specialized Experience To Provide Should Include Experience In Critical Path Scheduling, Fire Protection, Construction Infection Control Protocols, Energy Conservation, Transition, And Sustainable Design Practices. Submissions Shall Include No More And No Less Than Five (5) Recent And Relevant Government And Private Experience Projects Similar In Size, Scope, And Complexity, And Experience With The Type Of Projects/competence Above. Relevant Is Defined As Those Task Requirements Identified In The Statement Of Work. Recent Is Defined As Services Provided Within The Past Five (5) Years. Include The Following For Each Submitted Project: Project Title And Location Detailed Narrative Describing The Scope Of Services Provided, Including The Type Of Work Performed By The Offeror And Its Role In The Project (i.e., Prime Contractor, Teaming Partner, Or Subcontractor) Project Owner, Owner S Point Of Contact Including Telephone Number And Email Address. Services & Deliverables Provided Under The Contract/task Order. Period Of Performance, Including Start And Completion Dates Total Dollar Value Of The Project Ae Cost Estimate Vs. Actual Construction Cost Contract Number Associated With The Project. The Information Provided In Section F Of The Sf 330 Will Be Used To Evaluate Relevant Specialized Experience And Technical Competence. Any Projects Submitted By An Offeror That Exceed The Limit Will Not Be Considered During The Evaluation. The Information Provided In Section G Of The Sf 330 Will Be Used To Evaluate The Prior Experience Of The Prime Firm And Any Key Subcontractors Working Together On The Provided Relevant Projects. The Offeror Must Include Narratives Of How The Firm Addresses Each Of The Following Topics In Section H. Simply Restating This List In Section H Will Not Be Sufficient. The Management Approaches. The Coordination Of Disciplines And Subcontractors Quality Control Procedures, And Familiarity With Va Design Guides/manuals, Master Specifications, And Other Applicable Standards. Capacity: The Evaluation Will Consider The Firm S Ability To Meet The Schedule Of The Overall Project, As Well As The Available Capacity Of Key Disciplines To Perform The Work In The Required Time. Provide The Available Capacity Of Key Disciplines By Providing Current Project Workload, Inclusive Of All Projects Awarded By The Va, Any Federal Agency, And Private Sector, During The Previous Twelve (12) Months Or Any Active Projects At Pcac. Include The Full Potential Value Of Any Current Indefinite Delivery Contracts The Prime Firm Has Been Awarded From Any Source. Offeror Shall Clearly State Their Available Capacity Presenting Workload Percentages For The Key Disciplines And/or Team Members. Also, The Offeror Must Provide The Award Date, Completion Percentages, And Expected Completion Date For The Va Projects Awarded In The Previous Twelve (12) Months Or Active At Pcac. The Information For This Factor Must Be Provided In Section H Of The Sf 330. Please Ensure The Capacity Applies Toward The Proposed Team/personnel Provided In The Sf 330. Past Performance: Past Performance Will Be Evaluated On Contracts With Government Agencies And Private Industry In Terms Of Cost Control, Quality Of Work, And Compliance With Performance Schedules. Past Performance Will Be Evaluated For All Projects Provided In Section F. The Contractor Performance Assessment Reporting System (cpars) Database Will Be Reviewed To Evaluate The Projects That Have A Va Cpars Entry. Va Cpars Are Not Required To Be Submitted With The Sf330 Submission. The Contract Number For The Project Must Be Submitted For Each Project Provided In Section F So Cpars Can Be Reviewed In The Database. Please Note We Are Unable To Review Any Cpars From Other Federal Agencies Outside Of The Va. For Any Project That Does Not Have Va Cpars Data Available, A Past Performance Questionnaire (ppq) Is Required To Be Submitted With The Sf330. If The Firm (prime Or Subcontractor) Was Not The Prime Contractor On Any Project Submitted In The Sf330, A Ppq Must Be Submitted Listing Their Specific Role (key Disciplines) As A Subcontractor. The Ppq Should Be Rated And Signed By The Evaluator. In The Event That A Firm Does Not Receive A Completed Ppq Requested From An Evaluator Prior To The Time For Submission, The Firm Shall Submit The Partially Completed Ppq With Section 1 And The Evaluator Information In Section 2 Completed. Ensure A Poc Is Listed With The Project Title/contract Number. The Va Will Make Reasonable Attempts To Contact The Poc Upon Submission For Ppq Completion. The Government May Consider Additional Performance Related Information Regarding The Firm, To Include Customer Inquiries, Government Databases, Publicly Available Sources, And Additional Projects In Cpars. The Government Reserves The Right To Contact Any Poc Listed On A Cpars Report Or Ppq. If Appropriate, The Record Of Significant Claims Against The Firm Because Of Improper Or Incomplete Architectural And Engineering Services May Be Evaluated. Failure To Provide Requested Data, Accessible Points Of Contact, Or Valid Phone Numbers Will Result In A Firm Being Considered Less Qualified. The Information For This Factor Must Be Provided In Section H Of The Sf 330. For Ppqs, Please Utilize The Attached Ppq Document. Completed Ppqs Should Be Incorporated Into The Sf 330. Ppqs Should Not Be Submitted To Vha Pcac Directly. Any Ppqs Will Not Be Counted Towards The Page Limitation For This Submission. However, Any Narratives Provided For Past Performance In Section H Will Be Counted Toward The Page Limit. Knowledge Of Locality: Demonstrate And Describe Experience In The Local Area And The Specific Knowledge Of Certain Local Conditions Or Project Site Features The Experience Provided. This Description May Include (if Applicable): Any Prime Firm Or Subcontractor Experience Within The Visn Or At The Vamc State Or Local Construction Codes, Laws, Or Regulations Climate And Seismic Related Conditions Or Features The Information For This Factor Must Be Provided In Section H Of The Sf 330. Note That The Intent Of This Factor Is To Showcase A Firm S Understanding Of The Site And Locality, And Not Where The Firm Is Located, How Far Away The Firm/branch Office Is From The Site, And How They Would Travel To The Site. Information Related To The Firm S Location Shall Instead Be Provided In Section H Under Secondary Selection Criterion Factor 1, Geographic Location. See Below. Experience In Construction Period Services: Experience In Construction Period Services Must Be Demonstrated Via Project Experience. These May Be The Same Projects Identified Above In Factor 1; However, The Firm Shall Clearly Delineate The Types Of Construction Period Services Performed For Each. Refer To The Statement Of Work For Review Timeline Expectations. Project Descriptions Must Include Experience With: Solicitation Support Services, Professional Field Inspections During The Construction Period Coordination With Commissioning Requirements Review Of Construction Submittals Support In Answering Requests For Information During The Construction Period. Support Of Construction Contract Changes To Include Drafting Statements Of Work And Cost Estimates. Attendance At Weekly Conference Calls Providing Minutes Of Meetings Between The Ae, Va, And Contractors Pre-final Inspection Site Visits Generation Of Punch-list Reports, And Production Of As-built Documentation. The Firm Shall Provide A Detailed Description Of Projects Worked That Illustrate Experience In These Areas. Projects Must Be Within The Last Ten (10) Years. In Addition, The Firm Must Include A Description Of Experience Addressing Unforeseen Conditions And Emergent Situations, Conducting Situation Evaluations, And Making Midcourse Corrections. Include Description On How The Firm Can Be Proactive Or Responsive In These Situations. The Information For This Factor Must Be Provided In Section H Of The Sf 330. Secondary Selection Criterion*: Geographic Location. Location Of The Firm, As Measured By The Driving Distance (miles) Between The Offeror S Principal Business Location And The Tomah Va Medical Center 500 E Veterans Street, Tomah, Wi. 54660. . Determination Of The Mileage Will Be Based On Google Maps (https://www.google.com/maps/dir/). *the Secondary Selection Criterion Is Used As A Tiebreaker, If Necessary, In Ranking The Most Highly Qualified Firms Following The Completion Of Discussions. The Secondary Selection Criterion Will Not Be Applied When Determining A Firm S Sf 330 Submission Highly Qualified Or Not Highly Qualified. 5. Submission Requirements: The Below Information Contains The Instructions And Format That Must Be Followed For The Submission Of The Sf 330 Statement Of Qualifications: Submit One (1) Sf 330 Statement Of Qualifications To Contract Specialist Johnna Mcgraw At Johnna.mcgraw@va.gov . This Must Include Parts I And Ii And Any Applicable Attachments. The Submission Must Include The Sf 330, Architect-engineer Qualifications (form Is Available Online At Https://www.gsa.gov/reference/forms/architectengineer-qualifications). The Sf 330 Submission Is Due By January 10th 2025 At 1pm Est. The Sf 330 Must Be Submitted In One Email And Have A File Size No Larger Than 5 Mb. No Hard Copies Will Be Accepted. The Subject Line Of The Email Must Read: Sf 330 Submission Fire Station Design- Tomah Wi. The Sf 330 Submission Must Not Exceed A Total Of 50 Pages. This Includes Title Page, Table Of Contents, And Any Other Relevant Information. Any Pages Submitted By An Offeror That Exceed The Limit Will Not Be Considered During The Evaluation. Each Page Must Be In Arial Size 12 Font, Single Spaced. Part Ii Of The Sf 330 And Any Cpars Or Ppqs Will Not Count Toward The Page Limitation. A Ppq Obtained For Another Sf 330 Submission May Be Submitted For This Project. However, If Significant Portions Of The Project Have Been Completed Since The Ppq Was Filled Out, A New Ppq Should Be Submitted To Accurately Assess The Project. Firms Must Include The Following Information In Section B Of The Sf 330 Submission: 1) Sam Unique Entity Identifier 2) Tax Id Number 3) Cage Code 4) Primary Point Of Contact S Email Address And Phone Number. All Questions Must Be Submitted To Johnna Mcgraw With The Subject Line Sf 330 Questions Fire Station Design-tomah Wi. The Cutoff For Question Submission Is 1:00 Pm Est On December 16th, 2024. Questions Will Be Answered Through Modification To The Pre-sol Notice Posted To Contract Opportunities At Sam.gov. This Procurement Is A 100% Set-aside For Sdvosb Concerns. Offers Received From Other Than Sdvosbs Will Not Be Considered. Offerors Must Be Certified As Sdvosbs By The U.s. Small Business Administration (sba) And Visible In The Veteran Small Business Certification (vetcert) Database (https://veterans.certify.sba.gov/) At The Time Of Sf 330 Submission, Written Response Submission, And Award. Failure To Be Certified In The Vetcert Database At These Times Will Result In The Offeror Being Deemed Ineligible For Award. All Joint Ventures Must Be Sba Certified At The Time Of Sf 330 Submission, Written Response Submission, And Award And Must Submit Agreements That Comply With 13 Cfr 128.402 Prior To Contract Award. All Prime Firms Must Meet The Naics Code Requirement Specified In This Notice. The Contracting Officer Will Verify The Naics Code In Vetcert. Failure To Meet The Naics Code Requirement May Result In The Rejection Of The Sf 330 Submission. Sf 330 Submissions Received After The Date And Time Specified Will Not Be Considered. Late Proposal Rules Per Far 15.208 Will Be Followed For Late Submittals. Firms Not Providing The Required Information May Not Be Evaluated. All Information Must Be Included In The Sf 330 Submission Package. It Is The Offeror S Responsibility To Check The Contract Opportunities Website At Sam.gov For Any Revisions To This Announcement Prior To Submitting Their Sf 330.
Closing Soon10 Jan 2025
Tender AmountRefer Documents
521-530 of 533 active Tenders