Hvac Tenders

Hvac Tenders

Social security organizations Tender

Civil And Construction...+1Civil Works Others
France
Closing Date20 Nov 2024
Tender AmountRefer Documents 
Details: The purpose of the contract is: Project management for the complete development of the new public reception agency in Andrézieux on behalf of the Cpam de la Loire. The premises, with a surface area of 93m², delivered new and raw in concrete on the ground floor of a residential building, will be entirely to be fitted out. The project will involve making the premises watertight and airtight with the installation of exterior joinery and solar protection. And all the secondary work and technical lots (electricity, lighting, HVAC plumbing/sanitary).

Chambers Of Commerce And Industry CCI - CCI Tender

France
Closing Soon4 Nov 2024
Tender AmountRefer Documents 
Details: Selection of an Amo with the objective of carrying out extension and modernization works to: • Have larger boarding lounges for processing passengers on airlines such as Ryanair or Easyjet (approximately 200 Pax / room); • Be able to process Schengen and non-Schengen flights simultaneously, both on departure and arrival; • Add a sales or commercial area in the boarding lounge or Pczsar; • Reorganize the spaces at the reception, Pifs, arrival lounge level, taking into account security, customs and police constraints. • Replace the HVAC system • Better manage energy

VETERANS AFFAIRS, DEPARTMENT OF USA Tender

Civil And Construction...+3Building Construction, Consultancy Services, Civil And Architectural Services
United States
Closing Date12 Nov 2024
Tender AmountRefer Documents 
Details: This Is Not A Request For Proposal. This Is A Request For Standard Form (sf) 330 Architect-engineer Qualifications Packages Only. All Information Needed To Submit Sf 330 Documents Is Contained Herein. No Solicitation Package, Technical Information, Or Bidder/plan Holder List Will Be Issued. The Government Will Not Pay, Nor Reimburse, Any Costs Associated With Responding To This Request. The Government Is Under No Obligation To Award A Contract As A Result Of This Announcement. 1. General Information veterans Health Administration (vha) Program Contracting Activity Central (pcac) Is Seeking Sources And Intends To Award A Firm Fixed Price Design Contract For Architect-engineering (a-e) Services For The Development Of Complete Construction Documents, Which Include Working Drawings, Specifications, And Reports, And Construction Period Services For Project #640a0-25-700 Ehrm Infrastructure Upgrades At The Va Palo Alto Healthcare System, Menlo Park, Ca. The A-e Services Contract That Is Anticipated To Be Awarded Will Be Procured In Accordance With The Selection Of Architects And Engineers Statute [formerly Known As The Brooks Architect Engineer Act], Federal Acquisition Regulation (far) Subpart 36.6 Architectural And Engineering Services, Va Acquisition Regulation (vaar) 836.6, And Va Acquisition Manual (vaam) M836.6 Architect-engineer Services. In Accordance With Far 36.209, Construction Contracts With Architect-engineer Firms, No Contract For The Construction Of A Project Shall Be Awarded To The Firm That Designed The Project Or Its Subsidiaries Or Affiliates, Except With The Approval Of The Head Of The Agency Or Authorized Representative. 2. Project Information this Project Is A 100% Set-aside For Service-disabled Veteran-owned Small Business (sdvosb) Concerns. The Naics Code For This Procurement Is 541330 Engineering Services And The Annual Small Business Size Standard Is $25.5m. A Full Design Team Is Required To Complete This Project. The Va Expects To Award The Anticipated A-e Contract In February 2025. the Anticipated Period Of Performance For Completion Of Design Is 322 Calendar Days After Notice Of Award (noa). The Vaar Magnitude Of Construction Is Between $20,000,000 And $50,000,000. Please Note That The 322-calendar-day Period Of Performance For The Design Completion Begins With The Issuance Of The Noa And That A Notice To Proceed (ntp) Will Not Be Issued For The Completion Of A Design Project. 3. A-e Selection Process firms Submitting Sf 330s In Response To This Announcement, Not Later Than The Closing Date And Time Specified Herein And In Accordance With Submission Requirements, Will Be Considered For Evaluation. The Selection Will Be Made As Follows: sf 330s Will Be Evaluated In Accordance With The Primary Selection Criteria As Stated In This Pre-solicitation Notice. These Evaluations Will Determine The Most Highly Qualified Firms For This Particular Requirement. In Accordance With Far 36.602-3(c), At Least Three Of The Most Highly Qualified Firms Will Then Be Notified Of The Government S Intent To Hold Discussions. All Firms Not Invited To Participate In Discussions Will Be Notified At This Time. In Accordance With Far 36.607(b), Any Requested Debriefings Of Successful And Unsuccessful Firms Will Be Held After Final Selection Has Taken Place And Will Be Conducted, To The Extent Practicable, In Accordance With 15.503, 15.506(b) Through (f), And 15.507(c). Note That 15.506(d)(2) Through (d)(5) Do Not Apply To Architect-engineer Contracts. discussions Will Be Held With The Most Highly Qualified Firms In The Form Of Written Responses. The Firms Invited To Participate In Discussions Will Be Notified By Email And Provided Further Instructions, Including Any Questions Or Topics To Address. Following The Completion Of Discussions, The Firms Will Be Evaluated And Ranked Based On The Primary And (if Necessary) Secondary Selection Criteria. The Final Evaluation And Ranking Will Consider The Sf 330 Submission For Each Firm, As Well As Additional Information Obtained Via Discussions. The Highest Rated Firm Will Be Selected To Receive The Solicitation And Engage In Negotiations. the Solicitation Will Be Issued To The Highest Rated Firm As A Request For Fee Proposal (rfp). All Sow Attachments And Site-specific Documentation Will Be Provided To The Highest Rated Firm With The Rfp. A Site Visit Will Be Authorized During The Negotiation Process. An Award Will Then Be Made As Long As The Negotiation Of Rates And Hours Leads To A Fair And Reasonable Determination Of The Final Contract Price. If Negotiations With The Highest Rated Firm Are Unsuccessful, The Firm Will Be Notified That Negotiations Have Been Terminated. Negotiations Will Then Be Initiated With The Next Highest Rated Firm, And So On Until Award Can Be Made. 4. Selection Criteria: firms Responding To This Notice Will Be Evaluated And Ranked Using The Primary And Secondary Selection Criteria Listed Below. The Factors Are Listed In Descending Order Of Importance. The Evaluation Will Consider How Each Factor Is Addressed And How It Is Formatted To Coincide With The Selection Criteria. primary Selection Criteria (listed In Descending Order Of Importance): specialized Experience And Technical Competence (sections F, G, And H): there Are Two Parts To This Factor Submitting Projects In Section F That Demonstrate Required Experience, And Providing Section H Narratives As Stated Below. Both Parts Must Be In The Sf 330 Submission In Order To Receive At Least An Acceptable Rating. part I: the Projects Should Demonstrate Specialized Experience And Technical Competence In Design And Construction Period Services Provided For Network Infrastructure Installation, Renovations, Or Upgrades. Projects Experience Should Include Upgrading Large Scale (multi-building With Multiple Generational Oit Systems) Fiber Optics, Data Cable, Structured Cabling, Electrical Distribution Design, Electrical Upgrades, Uninterruptable Power Systems (ups), Electrical Bonding, Building Management Systems/building Automation Systems (bms/bas), Hvac, It Room Renovations/expansion/relocations, Data Centers/server Rooms Reconfiguration, And Physical Security Upgrades, Duct Bank And Direct Boring Operations. Other Specialized Experience To Provide Should Include Experience In Critical Path Scheduling, Fire Protection, Construction Infection Control Protocols. Computer-aided Design And Drafting/building Information Modeling, Equipment Resources, And Laboratory Requirements Will Be Evaluated. Energy Conservation, Pollution Prevention, Waste Reduction, And The Use Of Recovered Materials Will Be Evaluated Where Appropriate. submissions In Section F Shall Include No More And No Less Than Five (5) Recent And Relevant Government And Private Experience Projects Similar In Size Scope And Complexity, And Experience With The Type Of Projects/competence Above. Relevant Is Defined As Those Task Requirements Identified In The Attached Statement Of Work And This Notice. Recent Is Defined As Ae Services Provided On Projects That Have Ended (construction Is Complete, Or Construction Was N/a) Within The Past Ten (10) Years. Each Project Shall Include The Following: project Title And Location (city And State) awarded Contract Number Associated With The Project years Completed professional Services Start And End Dates construction Start And End Dates project Owner, Owner S Point Of Contact Including Telephone Number And Email Address. detailed Narrative Describing: the Scope Of Services Provided Including The Type Of Work Performed By The Offeror its Role In The Project I.e. Prime Contract, Teaming Partner Or Subcontractor. The Firm Completing The Project As Prime Must Match The Past Performance Firm Name. If A Partner To A Jv Completed The Project, Do Not Put The Jv Firm Name Down As Completing The Work. dates For Completion Of A, B, And C Services. state If Cps Was Done On The Project. services & Deliverables Provided Under The Contract/task Order awarded Ae Fee Contract Value, Including Options ae Cost Estimate Vs. Actual Construction Cost the Narrative Shall Describe Actions Taken That Demonstrate The Required Experience. Merely Making A List Of Relevant Areas From The Va Requirements List On The Side Of The Section F Project Is Not Demonstrating In Narrative Form Actions Taken On A Project. note: Awards To Overseas Offices For Projects Outside The United States, Its Territories And Possessions, And Awards To A Subsidiary If The Subsidiary Is Not Normally Subject To Management Decisions, Bookkeeping, And Policies Of A Holding Or Parent Company Or An Incorporated Subsidiary That Operates Under A Firm Name Different From The Parent Company, Will Not Be Considered Under This Factor. part Ii: the Offeror Shall Include Narratives Addressing The Following Topics In Section H. Simply Re-stating This List In Section H Will Not Be Sufficient. The Narrative Of How The Firm Addresses Each Of These Will Be Evaluated. the Management Approach, Including Flow Of Communication And Roles/responsibilities. This Is Not The Organization Chart In D. the Coordination Of Disciplines And Subcontractors, Including Flow Of Communication And Hiring Practices design Quality Management/control Procedures, And familiarity With Va Design Guides/manuals, Master Specifications And Other Applicable Standards. professional Qualifications (sections C-e, G, H): Necessary For Satisfactory Performance Of Required Service. The A-e Shall Demonstrate They Are Able To Sign And Stamp Each Drawing By Individuals Licensed In Any State In The United States For The Key Positions Listed Below. Provide Professional License Numbers And/or Proof Of Licensure. The Evaluation Shall Consider The Specific Experience (minimum Of Five Years) And Qualifications (i.e., Education, Training, Registration, Certifications, Overall Relevant Experience, And Longevity With The Firm As Full-time Employees) Of Personnel Proposed For Assignment To The Project, And Their Record Of Working Together As A Team When Evaluating Professional Qualifications. The Lead Designer In Each Discipline Must Be Registered But Does Not Have To Be Registered In The Particular State Where The Project Is Located. a Resume For Each Of These Key Positions Must Be Provided Via Section E In The Sf330. At Least One Resume Must Be Submitted For Each Of The Positions Below With The Role In This Contract Box Filled With A Title Matching This List. The Resume Shall State The Role The Specific Individual Filled On Each Project Listed, And Not A Generic Overview Of The Project. Each Project Must Also State If The Individual Worked On The Design Or Construction Period Services, Or Both. key Positions And Disciplines Required For This Project Include, But Are Not Limited To: architect (leed Certification/us Green Build Council Certification) registered Communications Distribution Designer (rcdd) cost Estimator civil Engineer electrical Engineer environmental Engineer certified Fire Protection Engineer certified Industrial Hygienist mechanical Engineer plumbing Engineer project Manager quality Assurance Manager structural Engineer physical Security Specialists [must Hold The Certified Protection Professional (cpp) Or Physical Security Professional (psp) Certification Issued By Asis International commissioning Agent section G Will Used To Evaluate The Prior Experience Of The Prime Firm And Any Key Subcontractors Working Together On The Provided Relevant Projects. include Documentation That Demonstrates Your Firm Has Discussed This Opportunity With Each Subcontractor And Agreed To A Part Ii Being Submitted As A Proposed Subcontractor. offer Must Include The Following Signed Statement Of Sdvosb Compliance In Section H When Submitting The Personnel Proposed To Perform The Work Under This Requirement: I ____[signatory Authority Name] __________, Of _____[company Name] ______, Certify That The Sdvosb Prime Contractor Will Not Pay More Than 50% Of The Amount Paid By The Government To The Prime For Contract Performance To Firms That Are Not Certified Sdvosbs By The Small Business Association S Veteran Small Business Certification (vetcert) In Compliance Of Va Acquisition Regulation (vaar) 852.219-75. signature: _______________________________ the Information Provided In Sections C-e, G, And H Of Sf 330 Will Be Used To Evaluate This Evaluation Factor. capacity (section H): The Evaluation Will Consider The Firm S Ability To Meet The Schedule Of The Overall Project, As Well As The Available Capacity Of Key Disciplines To Perform The Work In The Required Time. Provide The Available Capacity Of Key Disciplines By Providing Current Project Workload, Inclusive Of All Projects Awarded By The Va, Any Federal Agency, And Private Sector, During The Previous Twelve (12) Months. Include The Full Potential Value Of Any Current Indefinite Delivery Contracts The Prime Firm Has Been Awarded From Any Source. Offeror Shall Clearly State Their Available Capacity Presenting Workload Percentages For The Key Disciplines And/or Team Members. Also, The Offeror Must Provide The Completion Percentages And Expected Completion Date For The Va Projects Awarded In The Previous Twelve (12) Months. The Information For This Factor Shall Be Provided In Section H Of The Sf 330. Please Ensure The Capacity Applies Toward The Team/personnel Provided In The Sf 330. past Performance (section H): Past Performance Will Be Evaluated On Contracts With Government Agencies And Private Industry In Terms Of Cost Control, Quality Of Work, And Compliance With Performance Schedules. past Performance Will Be Evaluated For All Projects Provided In Section F. You Are Required To Provide The Documented Past Performance Evaluation On Each Project In Section F With A Matching Contract/task Order Number As Part Of The Sf 330 Pdf Submission. Past Performance May Be Submitted From Contractor Performance Assessment Rating System (cpars) Database Or A Past Performance Questionnaire (ppq) If There Is Not A Cpars Available. The Firm Listed On The Past Performance Must Match The Firm Listed As Prime On The Section F Project. if The Firm (prime Or Subcontractor) Was Not The Prime Contractor On Any Project Submitted In The Sf330, A Ppq Must Be Submitted Listing Their Specific Role (key Disciplines) As A Subcontractor. The Ppq Should Be Rated And Signed By The Evaluator. In The Event That A Firm Does Not Receive A Requested Complete Ppq From An Evaluator Prior To The Time For Submission, The Firm Shall Submit The Partially Completed Ppq With Section 1 And The Evaluator Information In Section 2 Completed, And Proof That The Request For The Ppq Was Made. Ensure A Poc Is Listed With The Project Title And Contract Number. The Va Will Make Reasonable Attempts To Contact The Poc Upon Submission For Ppq Completion. the Government May Consider Additional Performance Related Information Regarding The Firm, To Include Customer Inquiries, Government Databases, Publicly Available Sources, And Additional Projects In Cpars. The Government Will Evaluate The Past Performance Of A Joint Venture; If None Exists, The Past Performance Of Each Partner Will Be Evaluated. The Government Reserves The Right To Contact Any Poc Listed On A Cpars Report Or Ppq. If Appropriate, The Record Of Significant Claims Against The Firm Because Of Improper Or Incomplete Architectural And Engineering Services May Be Evaluated. failure To Provide Requested Data, Accessible Points Of Contact, Contract Numbers, Or Valid Phone Numbers Will Result In A Firm Being Considered Less Qualified. The Information For This Factor Shall Be Provided In Section H Of The Sf 330. for Ppqs, Please Utilize The Attached Ppq Document. Completed Ppqs Should Be Incorporated Into The Sf 330 Directly. Ppqs Should Not Be Submitted To The Vha Pcac Directly. Any Ppqs Will Not Be Counted Towards The Page Limitations For This Submission. However, Any Narratives Provided For Past Performance In Section H Will Be Counted Toward The Page Limit. knowledge Of Locality (section H): Knowledge Of The Locality, To Include Specific Knowledge Of Certain Local Conditions Or Project Site Features, Such As Geological Features, Climatic Conditions, Working With And Local Construction Methods Or Local Laws And Regulations. this Is A Narrative To Understand What Experience The Firm Has In The Project Area. Please Do Not Only Submit A Map Demonstrating Office Locations Of Prime And Subcontractors As This Is Not A Narrative And Does Not Meet The Intent Of This Factor. The Information For This Factor Shall Be Provided In Section H Of The Sf 330. note That The Intent Of This Factor Is To Showcase A Firm S Understanding Of The Site And Locality, And Not Where The Firm Is Located, How Far Away The Firm/branch Office Is From The Site, And How They Would Travel To The Site. Information Related To The Firm S Location Shall Instead Be Provided In Section H Under Secondary Selection Criterion Factor 1, Geographic Location. See Below. experience In Construction Period Services (section H): Experience In Construction Period Services Must Be Demonstrated Via Project Experience. These May Be The Same Projects Identified Above In Factor 1; However, The Firm Shall Clearly Delineate The Types Of Construction Period Services Performed For Each. Refer To The Statement Of Work For Review Timeline Expectations. The Firm Shall Provide A Detailed Description Of Projects Worked That Illustrate Experience In These Areas. Projects Must Be Within The Last Ten (10) Years. project Descriptions Must Include Experience With: solicitation Support Services, professional Field Inspections During The Construction Period coordination With Commissioning Requirements review Of Construction Submittals support In Answering Requests For Information During The Construction Period support Of Construction Contract Changes To Include Drafting Statements Of Work And Cost Estimates attendance At Weekly Conference Calls providing Minutes Of Meetings Between The Ae, Va, And Contractors pre-final Inspection Site Visits generation Of Punch-list Reports, And production Of As-built Documentation. in Addition, The Firm Must Include A Description Of Experience Addressing Unforeseen Conditions And Emergent Situations, Conducting Situation Evaluations And Make Midcourse Corrections. Include Description On How The Firm Can Be Proactive Or Responsive In These Situations, And What The Process Is To Resolve Issues. the Information For This Factor Shall Be Provided In Section H Of The Sf 330. secondary Selection Criterion*: geographic Location. Location Of The Firm, As Measured By The Driving Distance (miles) Between The Offeror S Principal Business Location And The Va Palo Alto Healthcare System, Menlo Park Division Campus, 795 Willow Rd, Menlo Park, Ca 94025. Determination Of The Mileage Will Be Based On Google Maps (https://www.google.com/maps/dir/). * The Secondary Selection Criterion Is Used As A Tiebreaker, If Necessary, In Ranking The Most Highly Qualified Firms Following The Completion Of Discussions. The Secondary Selection Criterion Will Not Be Applied When Determining A Firm S Sf 330 Submission. 5. Submission Requirements: the Below Information Contains The Instructions And Format That Must Be Followed For The Submission Of The Sf 330 Statement Of Qualifications: submit One (1) Sf 330 Statement Of Qualifications To Contract Specialist Kaylan Grove At Kaylan.grove@va.gov And Contract Officer Jennifer Salerno-diciuccio At Jennifer.salerno-diciuccio@va.gov. This Must Include Parts I And Ii And Any Applicable Attachments. the Submission Must Include The Sf 330, Architect-engineer Qualifications (form Is Available Online At Https://www.gsa.gov/reference/forms/architectengineer-qualifications ). the Sf 330 Submission Is Due By 1:00 Pm Et On November 12, 2024. the Sf 330 Must Be Submitted In One Email And Have A File Size No Larger Than 5 Mb. No Hard Copies Will Be Accepted. the Subject Line Of The Email Must Read: Sf 330 Submission - 36c77625r0009 Ehrm Infrastructure Upgrades Menlo Park. the Sf 330 Submission Must Not Exceed A Total Of 50 Pages. This Includes Title Page, Table Of Contents, And Any Other Relevant Information. Any Pages Submitted By An Offeror That Exceed The Limit Will Not Be Considered During The Evaluation. Each Page Must Be In Arial Size 12 Font, Single Spaced. Part Ii Of The Sf 330 And Any Cpars Or Ppqs Will Not Count Toward The Page Limitation. a Ppq Obtained For Another Sf 330 Submission May Be Submitted For This Project. However, If Significant Portions Of The Project Have Been Completed Since The Ppq Was Filled Out, A New Ppq Should Be Submitted To Accurately Assess The Project. firms Must Include The Following Information In Section B Of The Sf 330 Submission: 1) Sam Unique Entity Identifier 2) Tax Id Number 3) Cage Code 4) Primary Point Of Contact S Email Address And Phone Number all Questions Must Be Submitted To Kaylan.grove@va.gov And Jennifer.salerno-diciuccio@va.gov With The Subject Line Sf 330 Questions - 36c77625r0009 Ehrm Infrastructure Upgrades Menlo Park The Cutoff For Question Submission Is 1:00 Pm Et On November 12th, 2024. Questions Will Be Answered Through Modification To The Pre-sol Notice Posted To Contract Opportunities At Sam.gov. this Procurement Is A 100% Set-aside For Sdvosb Concerns. Offers Received From Other Than Sdvosbs Will Not Be Considered. Offerors Must Be Certified As Sdvosbs By The U.s. Small Business Administration (sba) And Visible In The Veteran Small Business Certification (vetcert) Database (https://veterans.certify.sba.gov/) At The Time Of Sf 330 Submission, Written Response Submission, And Award. Failure To Be Certified In The Vetcert Database At These Times Will Result In The Offeror Being Deemed Ineligible For Award. all Joint Ventures Must Be Sba Certified At The Time Of Sf 330 Submission, Written Response Submission, And Award And Must Submit Agreements That Comply With 13 Cfr 128.402 Prior To Contract Award. all Prime Firms Must Meet The Naics Code Requirement Specified In This Notice. The Contracting Officer Will Verify The Naics Code In Vetcert. Failure To Meet The Naics Code Requirement May Result In The Rejection Of The Sf 330 Submission. sf 330 Submissions Received After The Date And Time Specified Will Not Be Considered. Late Proposal Rules Per Far 15.208 Will Be Followed For Late Submittals. Firms Not Providing The Required Information May Not Be Evaluated. All Information Must Be Included In The Sf 330 Submission Package. it Is The Offeror S Responsibility To Check The Contract Opportunities Website At Sam.gov For Any Revisions To This Announcement Prior To Submitting Their Sf 330.

Ministry Of Culture Tender

Corrigendum : Closing Date Modified
France
Closing Soon4 Nov 2024
Tender AmountRefer Documents 
Details: The purpose of the contract is to renovate the facades of the workshops to the north, and the exterior joinery of the premises to the south and north between the workshops. In general and non-exhaustive terms, it concerns the following works: - Careful removal of existing facades and exterior joinery, - Removal and replacement of metal frame fire brigade walkways and part of the HVAC duct - Removal and replacement of louvered openings - Installation of Vec frames and replacement of aluminum crosspieces - Vec curtain walls with Italian-style openings and fire brigade openings - Installation of aluminum exterior joinery - Exterior cladding (metal cassettes in acroterion, cladding between frames, bay frames) - Interior finishes (connections) - Exterior fittings (base of facade) The Vec bonding system (openings included) must have a valid technical opinion, failing which an Atex type assessment will be requested. It should be noted that the areas covered by the contract concern the main workplaces of the school's students. The work must therefore be carried out in such a way as to take this constraint into account during the construction site by minimizing the nuisance if it takes place during the occupation period, while ensuring the safety of users. The operation must be carried out as a priority during the summer closing period for students at the establishment (July & August).

Ministry Of Culture Tender

Others...+2Civil And Construction, Civil Works Others
Corrigendum : Closing Date Modified
France
Closing Date22 Nov 2024
Tender AmountRefer Documents 
Details: This Contract Concerns the "Refurbishment Work on the Goya, Piazetta/Murillo and Rosa Rooms Located Within the Louvre Museum". All of the Expected Work, Execution Terms and Site Constraints Are Detailed in the Common Technical Clauses1 (cctc or Lot 00: Clauses Common to All Lots) Common to All Lots and the Special Technical Clauses (cctp) Specific to Each Lot. The Work Concerns More Particularly: - The Restoration of the Floors, - The Recoloring of the Walls and Ceilings, The Integration of the Devices Necessary for Accessibility for People with Reduced Mobility. This operation will be carried out in conjunction with: 1. The operation known as the Pavillon des Sessions, for which a call for applications has been launched, 2. An operation to upgrade the security installations, a PMR lift and the toilets located in the work zone. The CFO/CFA and HVAC/Plumbing Works Will Be Carried Out by the Companies Responsible for Maintenance Work Within the EP.ML This Operation Is Broken Down According to the Following Lots: - Lot 01 - Site Installations - Scaffolding - Painting - Lot 02 - Carpentry The Works Will Be Broken Down Into 4 Operational Phases: - Phase I: Goya and Piazetta/Murillo Rooms - Phase II: Piazetta/Murillo Room - Phase III: Circulation Between the Piazetta/Murillo and Rosa Rooms - Phase IV: Rosa Room All of the Expected Works, Execution Conditions and Site Constraints Are Detailed in the Common Technical Clauses Booklet2 (CCTC) Common to All Lots and the Special Technical Clauses Booklet (CCTP) Specific to Each Lot.

PUBLIC BUILDINGS SERVICE USA Tender

Civil And Construction...+3Building Construction, Consultancy Services, Civil And Architectural Services
Corrigendum : Closing Date Modified
United States
Closing Date13 Nov 2024
Tender AmountRefer Documents 
Details: Amendment 1 - 10/18/2024 amendment 1 Issued 10/18/24 To Incorporate The Following: Responses To Questions; Revisions To Initial Synopsis/soliciaition Notice; Response Date Extension To 11/12/24, 4pm. The Amendment Is Provided As An Attachment To This Notice. synopsis/soliciaition Notice Updated 10/18/24 Per Amendment 1 Revisions: procurement Description through Its Design Excellence Program, The U.s. General Services Administration (gsa) Commissions Our Nation’s Most Talented Creative Professionals To Design Outstanding Federal Workplaces. These Projects Embody An Exemplary Integrated Process Whose Results Deliver Enduring Value To Taxpayers. Gsa Defines Quality As The Thoughtful Expression Of Artistry, Local Culture, And Democratic Values Like Civic Participation, Accessibility, And Transparency, Achieved In Balance With Affordability, Constructability, Reliability, And Industry-leading Sustainable Performance. Design Excellence Is The Means By Which Gsa Realizes The Guiding Principles For Federal Architecture, Which President Kennedy Authorized In 1962, And It Is One Of The Agency’s Primary Vehicles For Catalyzing Positive, Inclusive Change In Local Communities. continuing This Legacy Of World-class Public Architecture, Gsa Announces An Opportunity For Design Excellence For Projects In Occupied Federally Owned Or Leased Office Buildings, Courthouses, And Land Ports Of Entry (lpoe's) Throughout Region 9. These Projects Are To Demonstrate The Value Of True Integrated Design That Balances Aesthetics, Cost, Constructability, And Reliability; And Create Environmentally Responsible And Superior Workplaces For Civilian And Federal Employees. this Is A Multiple Award Indefinite Delivery Indefinite Quantity (idiq) Contract(s) For Architect Engineer (ae) Services Covering Projects Located In The Following Four (4) Geographic Zones Of Region 9: zone 1 - States Of Arizona And Nevada zone 2 - Northern California (california Counties Of Del Norte, Siskiyou, Modoc, Humboldt, Trinity, Shasta, Lassen, Mendocino, Tehama, Plumas, Glenn, Butte, Sierra, Lake, Colusa, Yuba, Nevada, Placer, Sonoma, Napa, Yolo, Sutter, El Dorado, Marin, Solano, Sacramento, Amador, Alpine,san Francisco, Contra Costa, San Joaquin, Calaveras, Toulumne, Mono, Inyo, San Mateo, Alameda, Stanislaus, Mariposa, Santa Cruz, Santa Clara, Merced, Madera, San Benito, Fresno, Monterey, Kings, Tulare) zone 3 - Southern California (california Counties Of San Diego, Imperial, Orange, Riverside, Santa Barbara, Ventura, Los Angeles, San Bernardino, San Luis Obispo, Kern) zone 4 - State Of Hawaii And Pacific Territories multiple Awards May Be Made As A Result Of This Announcement, And The Government Anticipates Making Between Three (3) To Six (6) Awards Per Geographic Zone. However, The Ultimate Number Of Contracts Per Zone Will Be Determined By Gsa After The Assessment Of Qualified Contractors During The Solicitation Stage To Ensure Coverage In All Zones. this Procurement Is A 100% Total Small Business Set Aside. Prime Ae Firms Must Be A Small Business In Order To Be Considered. Consultants To The Prime Ae Firms Are Not Required To Be Small Businesses. the Naics Code Is 541310 - Architectural Services; The Small Business Size Standard Is $12.5 Million (average Annual Receipts). prime Ae Firms Who Are Interested In Performing Work In Multiple Zones Must Submit A Separate Technical Qualification Package For Each Zone. The Prime Ae Firms Must Have An Active Main Office And/or Branch Office Located Within The Applicable Geographical Zone As Of The Date Proposals Are Due In Order To Be Considered; If An Award Is Issued, The Zonal Office Must Remain Open And Active For The Duration Of The Contract Period. Consultants To The Prime Ae Firm Are Not Required To Have An Active Office In The Geographical Zone The Prime Ae Firm Will Be Performing In. An Active Main Office And/or Branch Office Is Defined As A Non-temporary Office From Which Business Is Regularly Conducted By The Prime Ae Firm. Prime Ae Firms Will Be Required To Certify They Meet The Specified Local Office/ Geographic Limitations In Your Submission. at The Time Of Technical Qualification Package Submission, Interested Prime Ae Firms Must Have An Active Registration In The System For Award Management (sam). Active Registration Must Also Be Complete As Applicable If The Prime Ae Firm Is A Partnership, Corporation, Association, Joint Venture, Or Other Legal Entity. Prime Ae Firms Will Be Required To Provide A Copy Of Your Active Sam Record As Well As Any Executed Agreements If Applicable (such As An Executed Joint Venture Agreement) In Your Submission. the Awarded Contracts Will Be For A Period Of One (1) Base Year With Four (4) Consecutive One (1) Year Option Periods. the Minimum Guarantee Will Be $1,000 For The Base Year Period Only. the Total Aggregate Maximum Order Limitation (mol) Per Awarded Contract, Covering The Base Year Period And Four (4) Consecutive One (1) Year Option Periods, Shall Not Exceed $25 Million. task Orders Issued Under The Awarded Contracts May Range In Value From $10,000.00 To $4,000,000.00, However There Will Be No Single Task Order Minimum Or Maximum Limit Specified. Prime Ae Firms Will Be Required To Comply With Brooks Act Procedures And Applicable 6% Statutory Limitation. this Procurement Will Be Conducted In Accordance With Brooks Act Public Law 92-582, And As Implemented In Federal Acquisition Regulation (far) Part 36.6, General Services Administration Acquisition Manual/ Regulation (gsam/ Gsar) Part 536.6. Under This Process The Government Will Award To The Most Highly Qualified Prime Ae Firms With Whom It Can Negotiate A Fair And Reasonable Price. this Is A Request For Technical Qualifications Only; This Is Not A Request For Proposal. An Ae Evaluation Board Comprised Of Gsa Personnel Will Evaluate The Technical Qualification Packages. general Description Of Contract Services prime Ae Firms, And Consultants As Applicable, Are Required To Be Licensed/ Registered Within The Applicable State(s) For Each Geographic Zone They Are Interested In And Must Conform To All Laws, Rules, And Requirements Of That State Governing The Profession Of Architecture Or Engineering. the Services Required Under This Contract May Include, But Are Not Limited To, The Following: 1. Comprehensive Design Services Including The Preparation Of Construction Documents For Repair And Alteration, And Tenant Improvement Projects. Typical Projects May Include Repair, Improvement And/or Remodeling Of Building Interior Space, And Building Systems And Features, Including But Not Limited To: Interior And Exterior Finishes, Landscaping, Civil, Mechanical, Plumbing, Electrical, Structural, Fire Safety, Blast, Anti-ram, And Ballistic Protection, Elevators, Environmental, And Roofing Components/systems. Project Locations/ Spaces May Include Courthouse And Federal Facilities, Historic Buildings, Border Stations, Child Care Facilities, Lease Locations, Renovation And/or Alteration Of Fire Protection Systems, Administrative Facilities, Warehouses, Road And Parking Lots, Walkways, Plazas, And Other Existing Systems And Facilities. 2. Comprehensive Design Services Including The Preparation Of Construction Documents For New Construction Of Courthouses And Federal Facilities. 3. Preparation Of Designs, Plans, Specifications, Estimates, Record Drawings, Space Planning, Technical Studies And Reports, Surveys And Construction Inspection Services For Projects. Projects May Involve Work In Specialty Areas Such As Alterations In Historic Buildings Or Asbestos Abatement Work. 4. Professional Disciplines Required May Include Architectural Designer, Landscape Designer, Mechanical Engineer, Structural Engineer, Hvac Engineer, Electrical Engineer, Civil Engineer, Historic Preservation Architect, Acoustical Engineer, Blast Consultant, Interior Designer, Cost Estimator, Cad Operator, Building Information Management, Fire Safety, Security Systems Consultant, Asbestos, Acoustical, Seismic, Environmental Engineering, Energy Consultant, Telecommunication, Building Forensics, Waterproofing, And Geotechnical Engineering. These Professional Disciplines May Also Assist Gsa Staff Engaged In Scope Development, Shop Drawing Review, Master Planning, Feasibility Studies, Programming, Interior Design, Change Management, Design Review, Construction Administration And Inspection, Elevator Evaluation/design, Signage Design, And Various Technical Studies Including Building Engineering Reports, Workplace Engagement Studies, Program Of Requirements, Post Occupancy Analysis, , Historic Structure Reports, Determinations Of Eligibility, National Register Of Historic Places Nominations, Historic Building Preservation Plans, Seismic And Structural Evaluations, Energy Studies For Design Of Energy Upgrades, Roof Evaluations, Fire Safety Review/studies, And Handicapped Accessibility (abaas) Reviews. 5. Comprehensive Project Planning Services For Large New Construction And Major Renovation Projects, Including Surveys Of Existing Conditions And Field Investigations, Site Selection And Evaluation, Planning And Program Studies, Feasibility Studies, Cost Estimates, Inventory Of Existing Furniture, Fixtures, And Equipment, And Other Services. The Budget Assessments May Include Cost Analysis As Well As Cost Estimating. 6. Design Services May Include Green/sustainable Design With A Goal Of Leed Certification And Sites Certification For Select Projects. Other Sustainable Design Requirements May Apply, Such As The Use Of Recycled And Environmentally Responsible Materials, Achievement Of Energy And Water Efficiency Goals, Design For Indoor Environmental Quality, Sustainable Site Design, And Sustainable Urban Design. 7. Other Professional Services Of An Architectural Or Engineering Nature, Or Incidental Services, That Members Of The Ae Professions (and Individuals In Their Employ) May Logically Or Justifiably Perform, Including Studies, Investigations, Surveying And Mapping, Tests, Evaluations, Consultations, Comprehensive Planning, Program/project Management, Conceptual Designs, Plans And Specifications, Value Engineering, Construction Phase Services, Soils Engineering, Drawing Reviews, Architectural Photography, Preparation Of Operating And Maintenance Manuals, And Other Related Services. 8. Environmental Surveys, Reports, Studies, And Designs For The Clean-up, Removal, Monitoring And/or Abatement Of Asbestos, Hazardous/toxic Materials And Petroleum Products. 9. Spatial Data Management (sdm) Program For Creating, Updating And Maintaining Spatial Data And Associated Computer Aided Drawings (cad) To Accurately Reflect The Federal And Leased Inventory. prime Ae Firms Must Have The Ability To Provide Comprehensive Design And Post Construction Contract Services, Which May Include Rfi And Submittal Reviews. prime Ae Firms Must Be Able To Perform Drafting Of Above Work In A Computer System Compatible With The Latest Version Of Autocad And Building Information Modelling Software And Provide Construction Specifications Using The Latest Version Of Masterformat. The Prime Ae Firm Must Also Be Able To Provide Design In Both English And Metric, As Applicable. each Contract Awardee Must Have The Capability To Concurrently Perform Design And Engineering Work For At Least Five (5) Gsa Projects. in Performance Of The Contract, The Selected Prime Ae Firm May Be Required To Include On Its Team The Following Design Disciplines And Specialty Consultants: Architect, Electrical Engineer, Mechanical Engineer, Plumbing, Structural Engineer, Civil Engineer, Cost Estimating, Fire Protection Engineer, Interior Designer, Historic Preservation Architect, Landscape Architect, Vertical Transportation/ Elevator Consultant, Blast Consultant, Materials Conservation, Sustainability, And Hazardous Materials. selection Process the Selection Of Between Three (3) To Six (6) (or More) Single Award Ae Idiq Contracts Per Geographic Zone Will Be Made Using A Two-stage Process As Follows: stage I - The Technical Qualifications And Experience Of Proposed Prime Ae Firms Will Be Evaluated From The Initial Technical Qualification Package, Including Review Of Their Complete Team Of Engineers And Consultants. A Short-list Will Be Established Of The Prime Ae Firms Determined To Be The Most Highly Technically Qualified. The Short-listed Prime Ae Firms Will Be Invited To Continue With Stage Ii Of The Selection Process. stage Ii - Interviews Will Be Conducted With The Short-listed Prime Ae Firms. The Short-listed Prime Ae Firms Will Be Ranked, And The Top-ranked Firms Will Be Selected To Receive The Solicitation And Conduct Negotiations. stage 1 Submission Requirements prime Ae Firms That Fully Meet The Requirements Described In This Notice Are Invited To Submit A Technical Qualification Package To Include The Following, In The Order Listed: cover Letter Referencing The Sam.gov Announcement Number And Briefly Describing The Firm And Its Location, The Geographic Zone They Wish To Be Considered For, Organizational Makeup, Noteworthy Accomplishments, And The Proposed Working And Legal Relationship Between Its Components If The Prime Ae Firm Is A Partnership, Corporation, Association, Joint Venture, Or Other Legal Entity. acknowledgement Of All Amendments Posted Prior To The Closing Date. active Sam Record. executed Agreement(s), If Applicable. standard Form (sf) 330 Architect Engineer Qualifications Part I & Ii responses To The Submission Requirements And Evaluation Criteria Listed Below. prime Ae Firms Shall Submit Separate Complete Technical Qualification Packages For Each Geographic Zone The Firm Is Interested In Being Considered For. only Electronic Submissions In Pdf Format Will Be Accepted; No Hard Copies Will Be Accepted Or Reviewed. pdf Submissions Shall Be Concise And Organized, In 8 1/2" X 11" Format, And The Assembled Content Shall Not Exceed One Hundred And Twenty-five (125) Pages. All Assembled Pages In The Pdf Submissions Shall Be Continuously Numbered, Meaning The Cover Letter, Table Of Contents, Cover Pages, Etc. Are To Be Included In The Continuously Numbered Pages; There Are No Exclusions Allowed In The Specified Page Limitation. ensure The Submission Clearly Identifies The Information Being Submitted For Each Evaluation Factor, Either By Using Cover Pages For Each Evaluation Factor Content Or By Annotating At The Top Of Each Page Which Evaluation Factor(s) The Information Applies To. sf 330 Instructions: prime Ae Firms Are To Complete And Submit A Current Sf 330 Part I & Ii. All Sections Of The Sf330 Must Be Filled Out In Their Entirety And Must Address All Elements Identified Under The Stage 1 Evaluation Criteria. interested Firms With More Than One (1) Office Must Indicate On Their Sf 330 The Staffing Composition Of The Office In Which The Work Will Be Performed Under The Specified Geographic Zone. Include A Completed Part Ii Only For Each Proposed Consultant/ Subcontractor Listed In Part I - Section C. in Addition To The Standard Instructions Provided On The Sf 330, The Following Are Supplemental Instructions For Sf 330 Part I Sections Under This Announcement: section C: The Prime Ae Firm Should Prioritize Team Members And Only Provide Those That Are Essential To Creating The Most Well-rounded Team. section E: The Prime Ae Firm Should Prioritize And Provide Those That Best Represent The Firm's Ability To Accomplish The Requirements Of This Contract. Ceos And Other Executive Personnel Should Not Be Submitted Unless They Will Have Direct Responsibility For Accomplishing The Task Orders Under This Contract. It Is Required That The Lead Architectural Designer And The Primary Point Of Contact That Would Be Responsible For Managing This Contract And Assigning Task Orders Be Included. It Is Recommended That The Key Personnel Directly Responsible For Work Submitted In Section F Should Also Be Included. section F: All Projects Provided Should Be Designed And Completed Within The Last Ten (10) Years; "designed And Completed" Means The Design Work And Associated Construction Work For A Submitted Project Are Both To Have Been Completed In The Last Ten (10) Years. The Prime Ae Firm May Submit The Same Projects For Multiple Evaluation Factors If They Address The Specified Information Required For Each. Ensure Each Project Specifically Notes Which Factor It Is Being Submitted For. Ensure That An Accessible Owner Point Of Contact Including Name, Title, Address, Current Email Address And Current Phone Number Is Provided. section G: Indicate Key Personnel And Consultant/ Subcontractors Who Participated In The Example Projects Under Section F. section H: Certification Is Required By The Prime Ae Firm That They Have An Active Main Office And/or Branch Office Located Within The Applicable Geographic Area They Wish To Be Considered; The Last Entry Under This Section Must Read "i Hereby Certify That The Prime Ae Firm Listed In Section C Meet(s) The Geographic Limitations Stated In The Synopsis For This Contract". stage 1 Evaluation Criteria the Evaluation Criteria And Associated Relative "weight" For Each Criteria Element Is As Follows: 1. Specialized Experience (35%) 2. Professional Qualifications And Experience Of Key Personnel (25%) 3. Past Performance (20%) 4. Project Management And Quality Control Plan (10%) 5. Geographic Location (5%) 6. Small Business Socio-economic Categories (5%) the Evaluation Criteria And Submission Requirements For Each Are Further Described Below: 1. Evaluation Factor No. 1: Specialized Experience (35%) this Factor Considers The Prime Ae Firm’s Specialized Experience For Projects That Meet The Submittal Requirements Project Definition For This Factor. The Prime Ae Firm Shall Provide Their Most Relevant Experience In Response To Gsa’s “requirements Under The Contract” Description And Demonstrate Success In Appropriately Addressing Complex Design, Research, Innovation, And Strategy Issues Such As Unique Requirements, Significance Of Community Or Cultural Context On Building Or Interior Design, Image, Function, Scale, Scope, Complexity, And Experience Or Perception Of Users. The Prime Ae Firm Shall Demonstrate Innovation In Design, Research, Construction And Project Management Approaches Using Integrated Multidisciplinary Teams On A Range Of Projects Including But Not Limited To Innovative Building Design Solutions, Strategic Endeavors, And Efforts To Achieve Sustainable Solutions. The Prime Ae Firm Shall Also Demonstrate Experience Providing Services Ranging From Pre-design Studies Through Construction Administration; Highlight Areas Of Concentration Or Competence And Range Of Expertise In Diverse Areas Such As Workplace Strategy, Change Management And/or Historic Preservation; Highlight Achievements In Resolution Of Technical Issues Such As Abaas Improvements, Security Design And Energy Projects. the Standard For This Factor Is Met When: the Prime Ae Firm Demonstrates Success In Addressing Complex Design And/or Challenges Through Evidence Of Experience Addressing The Elements Above. additional Consideration Under This Factor: more Weight May Be Given For Firms Who Submit Projects Reflecting Any Of The Following- (1) Experience With Projects Owned By Public Agencies, Including But Not Limited To Federal, State, And Municipal Agencies. (2) Awards Or Other Forms Of Public Recognition From Nationally Recognized Organizations Demonstrating Excellence In Design. submittal Requirements For Factor 1: the Prime Ae Firm Must Submit Three (3) Projects Total For This Factor, No More And No Less. For Each Project, Submit A Maximum Three (3) Page Narrative, Including Any Photographs And Drawings, That Illustrate Specialized Experience Of Projects Where The Construction Was Completed Within The Last Ten (10) Years, And Each Having A Construction Value Of $1 Million Or More. Projects Submitted May Be For Both Renovations And New Construction. 2. Evaluation Factor No. 2: Professional Qualifications And Experience Of Key Personnel (25%) this Factor Considers The Prime Ae Firm’s Professional Qualifications, Experience Of Key Personnel, And Design Philosophy. The Prime Ae Firm Shall Demonstrate Professional Qualifications And Experience Of The Proposed Key Personnel Assigned To This Project Necessary For Satisfactory Performance Of The Required Services. Qualifications And Experience Of The Prime Ae Firm’s Key Personnel Will Be Reviewed First; Then The Overall Proposed Team Qualifications And Experience Will Be Reviewed To Ensure They Will Provide Necessary Support To The Prime Ae Firm To Perform The Required Services. The Prime Ae Firm Shall Also Address The Principal Or Lead Designer’s Philosophy To Include Past Work That Exhibits A Balance Of Design Quality With Other Factors That Affect Public Architecture Including Security, Review Processes, And Budget And Schedule. the Standard For This Factor Is Met When: the Prime Ae Firm Submits All Required Information Demonstrating The Qualifications, Experience, And Design Philosophy As Described. additional Consideration Under This Factor: more Weight May Be Given For Firms Who Submit Information Addressing Any Of The Following - (1) The Degree To Which Any Of The Key Personnel’s Qualifications Are Superior (2) History Of Leadership In Volunteer Organizations Related To The Field Of Architecture, Engineering, And Construction. (3) Awards Or Other Forms Of Public Recognition From Nationally Recognized Organizations Demonstrating Excellence In Design. (4) A Design Philosophy That Provides Evidence Of Flexibility, Innovation, Balance, And Awareness Of Design Excellence In Public Architecture. submittal Requirements For Factor 2: the Prime Ae Firm Shall Provide A Narrative Description, Not To Exceed Two (2) Pages, Summarizing The Principal Or Lead Designer’s Philosophy And Approach To Project Solutions And Providing Examples. Information Provided May Include Appropriate Graphic Material. the Prime Ae Firm Must Submit Resumes Of Proposed Team Members, Not To Exceed Two (2) Pages Each, For Personnel In The Following Disciplines: (1) Prime Architect (one Individual Can Fulfill More Than One Role) principal (architect Of Record) lead Designer project Manager (individual Responsible For Task Orders) (2) Consultants Of Record civil Engineer structural Engineer mechanical Engineer electrical Engineer plumbing Engineer fire Protection Engineer historic Preservation Architect interior Designer landscape Architect resumes Must Indicate Professional Qualification Of Team Members, Including Education, Professional Certification And Licensure, Relevant Experience, Any Specialized Expertise, And The Length Of Service With The Firm. Include And Clearly Identify Resumes For Individuals Who Will Serve As Principal/architect Of Record, Lead Designer, And Project Manager(s), As Well As The Lead Designers In Each Discipline (whether They Are A Part Of The Prime Ae Firm Or A Sub-consultant). resumes Submitted Must Demonstrate Familiarity With New Construction And/or Renovation Projects In Occupied Buildings Where The Construction Was Completed Within The Last Ten (10) Years, And Each Having A Construction Value Of $1 Million Or More. 3. Evaluation Factor No. 3: Past Performance (20%) this Factor Considers The Prime Ae Firm Past Performance On A Range Of Projects Of Varying Scopes, Scales, And Complexities. The Prime Ae Firm’s Role On Each Project Submitted Must Be Identified, Including Demonstrated Success At Collaborative Relationships With Consultants If Applicable. in Evaluating Past Performance For Projects That Meet The Submittal Requirements Project Definition For This Factor, The Government May Review The Contractor Performance Assessment Reporting System (cpars) Database And/or Past Performance Questionnaires (ppq) Submitted By The Prime Ae Firm. Points Of Contact Provided For Projects Submitted Under This Factor And Other Factors May Be Contacted, And The Government May Also Review Any Other Source Of Past Performance Information At Its Discretion. Evaluation Of Past Performance Is A Subjective Assessment Based On Consideration Of All Relevant Facts And Circumstances. It Will Not Be Based On Absolute Standards Of Acceptable Performance. In The Case Of An Offeror Without A Record Of Past Performance, Or For Whom Information On Past Performance Is Not Available, That Offeror Will Be Given Neither A Favorable Nor An Unfavorable Evaluation Regarding Past Performance. the Standard For This Factor Is Met When: the Prime Ae Firm’s Overall Past Performance Record Demonstrates Satisfactory Performance On Three (3) Projects That Meet The Submittal Requirements Project Definition For This Factor. submittal Requirements For Factor 3: the Prime Ae Firm Must Submit Three (3) Projects Total For This Factor, No More And No Less. For Each Project, Submit A Maximum Three (3) Page Narrative, Including Any Photographs And Drawings, Where The Construction Was Completed Within The Last Ten (10) Years, And Each Having A Construction Value Of $1 Million Or More. Include Tangible Evidence Such As Certificates, Awards, Peer Recognition, Etc., Demonstrating Design Performance. Projects Submitted May Be For Both Renovations And New Construction. Each Project Specified Is To Clearly Identify The Project Name, Design Contract Number (if Applicable), Location Of Work, Design Contract Value, Construction Value, And Accurate Client Reference Information Including Name, Title, Address, Email, And Phone Number. Points Of Contact Provided For Projects Submitted Under Other Evaluation Criteria May Be Contacted. additionally, The Prime Ae Firm Must Submit A Ppq Or Copy Of The Completed Cpars Evaluation For Each Of The Three (3) Projects Submitted Under This Factor. The Ppq Or Cpars Evaluation Pages Are In Addition To The Three (3) Page Maximum Narrative Specified For Each Project. 4. Evaluation Factor 4: Project Management And Quality Control Plan (10%) this Factor Evaluates The Prime Ae Firm’s Project Management And Quality Control Plan, Which Provides A Plan Specific To This Idiq Contract. At A Minimum, The Submitted Plan Must Clearly Identify Key Roles And Lines Of Communication, And Must Explain Steps To Ensure Cost And Schedule Control, Quality Control, Project Team Capacity, And Requirements For All Review Stages And Submittals. the Project Management And Quality Control Plan Must Also Demonstrate The Capacity Of The Prime Ae Firm To Accomplish Multiple, Large And Small Projects Simultaneously, And The Ability To Sustain The Loss Of Key Personnel While Accomplishing The Work Within The Required Time Limits. Under The Anticipated Idiq Contract, Each Contract Awardee Must Have The Capability To Concurrently Perform Design And Engineering Work For At Least Five (5) Gsa Projects/ Task Orders. the Standard For This Factor Is Met When: the Prime Ae Firm Demonstrates The Following - the Methods To Deliver Quality Design Or Deliverable While Maintaining Cost And Schedule Controls. the Capability To Respond To The Government’s Needs In A Timely Manner. the Capability To Perform And Balance Multiple Task Orders Concurrently And To Balance Competing Needs Of Multiple Customers. their Ability, Methods, And Processes To Adequately Staff Project Teams. submittal Requirements For Factor 4: the Prime Ae Firm Shall Submit A Project Management And Quality Control Plan, Six (6) Pages Maximum, That Demonstrates The Firm’s Approach For Delivering Individual Projects And Addresses How The Plan Will Be Catered To The Anticipated Idiq Contract, As Described Above. 5. Evaluation Factor 5: Geographic Location (5%) this Factor Evaluates The Prime Ae Firm’s Knowledge Of Local Conditions Within The Geographical Zone(s) In Which They Wish To Be Considered For Contract Award Including Design And Project Strategies Used For Solutions To Design Issues Specific To Local, Environmental, And Geographic Areas Within A Zone. This Must Include Project Delivery Processes, Construction Methodologies, And Related Involvement Or To The Consultants. This Factor Also Considers The Prime Ae Firm’s Familiarity Of The Applicable Geographic Area’s Architectural Standards And Codes, Building Codes, Environmental Regulations, Soil Conditions, Seismic Requirements, And Agency Regulations. the Standard For This Factor Is Met When: the Prime Ae Firm Clearly Demonstrates Knowledge Of Local Conditions And Familiarity With Applicable Geographic Areas Standards And Codes, As Described Above. submittal Requirements For Factor 5: the Prime Ae Firm Must Submit Three (3) Projects Total For This Factor, No More And No Less, And Must Provide A Maximum Of Three (3) Page Narrative For Each Project, Including Any Photographs And Drawings As Applicable, For A Total Of Three (3) Projects Where The Construction Was Completed Within The Last Ten (10) Years, And Each Having A Construction Value Of $1 Million Or More, Describing The Prime Ae Firm’s Knowledge Of Locality Criteria Described Above. Projects Submitted May Be For Both Renovations And New Construction. 6. Evaluation Factor No. 6: Small Business Socio Economic Categories: Hubzone, Sdvosb, Wosb (5%) this Factor Considers The Prime Ae Firms Status As A Small Business Concern In The Following Socio-economic Categories: Historically Underutilized Business Zone (hubzone) Small Business Concern; Service-disabled Veteran Owned Small Business (sdvosb) Concern; Women-owned Small Business (wosb) Concern. including This Factor In The Evaluation Of The Prime Ae Firm Will Result In A Higher Evaluation Rating Being Given To Firms Who Fall Within One Of The Specified Socio-economic Categories. the Standard For This Factor Is Met When: the Prime Ae Firm Provides Confirmation Of Their Small Business Socio-economic Status Within One Or More Of The Specified Categories, If Applicable. submittal Requirements For Factor 6: the Prime Ae Firm Must Submit Proof Of Current Sba Certification Within The Socio-economic Category Specified. stage Ii Process Summary the Names Of The Short-listed Prime Ae Firms Who Will Be Invited To Participate In Stage Ii Of The Selection Process Will Be Published On Sam.gov. This Publication Will Be The Only Notice For Prime Ae Firms Who Submit Stage I Technical Qualification Packages And Are Not Short-listed Will Receive. Short-listed Prime Ae Firms Will Be Provided More Detailed Information On The Stage Ii Process. prime Ae Firms Slated For Interviews Will Be Asked To Present Information On The Evaluation Factors. The Primary Presenter Must Be The Proposed Project Manager/ Lead Project Architect, With Assistance From Up To Two (2) Additional Team Members As Necessary. Interviews Will Be Conducted Via Google Meet. following The Technical Review And Interview Process The Final Selected Prime Ae Firms Will Be Requested To Provide Pricing To Include Overhead Rates, Profit Rates And Hourly Rates For The Anticipated Disciplines For Use In Negotiating Fixed Price Task Orders. notice To Prime Ae Firms prime Ae Firms Submitting Qualification Packages Under This Notice Must Be A Small Business Firm With A Main Office And/or Branch Office In Each Of The Geographic Zone(s) They Are Interested In Being Considered For. Additionally, Failure To Address Each Of The Evaluation Factors And Provide The Requested Information May Result In Failure To Qualify. it Is The Prime Ae Firms Responsibility To Monitor Sam.gov For Any Changes To This Announcement. questions: the Deadline For Submitting Questions Is October 4, 2024, 4:00 Pm Pt. Questions Must Be Submitted In Writing Via Email To Heather Caney, Contracting Officer At Heather.caney@gsa.gov. Questions Received After The Date Specified Will Not Be Accepted Or Responded To. An Amendment Will Be Issued To Provide Responses To All Questions Received By The Deadline. all Questions Received In Writing By The Closing Date And Time Have Been Responded To Under Amendment 1. No Additional Questions Will Be Accepted Or Responded To. closing Date And Time: prime Ae Firms Which Possess The Qualifications To Perform The Services Described In This Notice Are Invited To Submit Their Complete Technical Qualification Package No Later Than November 12, 2024, 4pm Pt. The Email Submission Must Clearly Identify The Synopsis/solicitation Number And The Applicable Geographic Zone For Which The Prime Ae Firm Is To Be Considered. For Prime Ae Firms Submitting For Multiple Zones, Send A Separate Email For Each Zone. all Submissions Shall Be Sent Via Email To Heather Caney, Contracting Officer At Heather.caney@gsa.gov. only Electronic Pdf Submissions Will Be Considered. No Late Submissions Will Be Accepted. it Is The Prime Ae Firm’s Responsibility To Ensure Technical Qualification Packages Are Complete And Submitted Early Enough To Be Received By The Contracting Officer Before The Deadline, And To Confirm Receipt Before The Deadline. Technical Qualification Packages Which Are Received By The Contracting Officer Later Than The Time Noted Will Be Rejected And Will Not Be Considered. the Maximum File Size For Email Submissions Is 25 Mb. Gsa Has Occasionally Experienced Delays In Delivery Of Emails From The Gsa Server To An Email Account. Therefore, Prime Ae Firms Need To Plan Accordingly. list Of Attachments: the Following Are A List Of Attachments Provided With This Notice: 1. Ppq (word) 2. Sf330 Part 1 & 2 With Form Instructions (pdf) 3. Sf330 - Part 1 (pdf) 4. Sf330 - Part 2 (pdf) 5. Sf330 - Extra Section C (pdf) 6. Sf330 - Extra Section E (pdf) 7. Sf330 - Extra Section G (pdf) 8. Sf330 - Extra Section H (pdf) 9. Amendment 1 - 10/18/2024 (pdf)

THERMAL-F and A.S. Tender

Electrical and Electronics...+1Electrical Works
Czech Republic
Closing Date13 Nov 2024
Tender AmountCZK 2.6 Million (USD 111.6 K)
Details: The subject of the performance of the public order is the supply and installation of air conditioning and related work in the 1st floor of the Hotel Thermal in Karlovy Vary. Content of Implementation: For the needs of ventilation of the newly adapted space in the 1st floor of the Hotel Thermal Karlovy Vary, it is possible to install a new air conditioning unit (see Pd in the Annex to this Wall). The unit will be located in the existing engine room/exchange station in the 1st floor. Within the framework of the location of the new unit, there will be a need to adjust the location of one existing unit (regarding the control room, workshops, warehouses). Part of the contract is the relocation of the existing unit, the solution to the ventilation of the chemical warehouse space, the delivery and installation of the new unit, the manufacture and installation of air ducts. Piping for the Newly Installed Unit (ventilation of New Spaces) Will be Conducted So-called. "on the heel" (the final division in the new premises will be made only after specifying their use and is not the subject of this contract), where it will be terminated with a fire damper. A standard low-pressure system is designed. For a Newly Installed Unit, the Device Will Inhale Air on the Facade of the Building Through the Existing Rain Shutter. In the unit, the air is filtered, preheated on the Zzt exchanger and thermally treated (heated or cooled). It is blown from the unit into a pipe that transports it to the border of the new premises. Vzt Unit Is Included On Inlet Filter M5, Zzt System (Plate Cross Heat Recovery Exchanger), Fan, Water Heater, Water Cooler, Filter F7. An M5 filter, a Zzt exchanger, and a fan are located on the exhaust. The unit is also equipped with suction flaps and shock absorbers. The device is designed with a power reserve for any unexpected change in layout. Degraded air is discharged back to the unit. In the unit, the air is filtered (M5 filter) and diverted to the common exhaust duct by the fan through heat recovery, and is thus blown out into the outdoor space. The drainage pipe is projected in two alternative routes and the specific solution will be specified on the construction site after the construction structures are revealed. In order to prevent the penetration of the noise of the fan sets, silencers are designed into the pipe routes. The inlet and outlet pipes are terminated with fire dampers at the border of the casino (model with 230 V servo drive). Device Control Will Be Via System Mar. As part of the contract, the modification of the existing Vzt 129 equipment is also addressed, when, due to the installation of a new Vzt unit, it is possible to relocate the supply unit 129 and accordingly modify the Vzt distributions according to the drawing part. Due to the dismantling of the wiring for the upcoming casino, it happened that part of the hotel grounds next to the casino is not ventilated. For this reason, a new pipe route is designed from the engine room from facility 129 to the facilities area, where it will be connected to the existing distribution system and will ensure the supply of air to this part. The Air Extraction From The Chemical Storage And Water Treatment Plant Will Be A New Exhaust Duct Fan That Is Designed Under The Ceiling In The HVAC Machine Room. The exhaust of degraded air is into the exhaust duct of the engine room in 1 Pp. Device Control Will Be Via System Mar.
501-510 of 507 active Tenders