Hvac Tenders
Hvac Tenders
Harford County Public Schools Tender
Civil And Construction...+2Others, Building Construction
Corrigendum : Closing Date Modified
United States
Description: Aberdeen Middle School Hvac Systemic Renovations
Closing Date4 Mar 2025
Tender AmountRefer Documents
Transport For London Tender
Electrical and Electronics...+1Electrical Works
United Kingdom
Description: Supply Of Cab Hvac For 92ts Central Line Overhaul Programme Lift
Closing Soon13 Feb 2025
Tender AmountRefer Documents
Transport For London Tender
Electrical and Electronics...+1Electrical Works
United Kingdom
Description: Supply Of Cab Hvac For 92ts Central Line Overhaul Programme Lift
Closing Date12 Feb 2025
Tender AmountRefer Documents
Board Of Education Tender
Electrical and Electronics...+1Electrical Works
Corrigendum : Closing Date Modified
United States
Description: Dcp054-24 Ddems Hvac Mod
Closing Date3 Jan 2026
Tender AmountRefer Documents
Alachua County Public Schools Tender
Electrical Goods and Equipments...+1Electrical and Electronics
United States
Description: Bus Hvac Oem Parts
Closing Date31 Dec 2025
Tender AmountRefer Documents
Department Of Natural Resources Tender
Electrical and Electronics...+1Electrical Works
United States
Description: Seneca Creek Hvac Replacement
Closing Date2 Apr 2026
Tender AmountRefer Documents
Charles County Public Schools - CCPS Tender
Civil And Construction...+3Others, Electrical and Electronics, Electrical Works
United States
Description: Hvac And Roof Replacement, General Smallwood Middle School
Closing Date2 Apr 2026
Tender AmountRefer Documents
Montgomery County Government Tender
Electrical Goods and Equipments...+1Electrical and Electronics
United States
Description: Ifb #1164385 - Hvac/refrigeration Equipment And Parts
Closing Date2 Apr 2026
Tender AmountRefer Documents
FOREST SERVICE USA Tender
Others
Corrigendum : Closing Date Modified
United States
Details: Amendment 001. The Purpose Of Amendment 001 Is To Open The 2025 Srs Shortlist Call For Qualifications. This Is For The Period Of 05/01/2025 Through 04/30/2026.
*2024 Participants Need To Re-certify Their Sf330 Is Correct And Accurate ( 2025 Region 8 Srs Shortlist Ae Pool Renewal Certification Form Attached) But Do Not Resubmit A Complete Package.
** New Applicant Shouls Complete The Package Issues In 2025/2026 For The Remaining Two Years.
update: 08 Mar 2024 / 1000 Et Virtual Contractor Townhall #2 -see Attachment For Link To The Virtual Townhall. This Will Provide The Opportunity To Ask Questions Regarding The Process Or Specifics On Completing The Sf-330.
update: 25 Jan 2024 1400et Virtual Contractor Townhall. See Attachment For Link To The Virtual Townhall. This Will Provide Information On The Sf330 Review Process And How The Process Works For Project Selection.
what And Where Is The Short Selection Database Used For?
the Forest Service May Utilize The Short Selection Database To Award Architect-engineer (a&e) Contracts, Below $250,000, In All States Included Within The Usda Forest Service Srs, Pnw, And Iitf Footprints, (including The States/territories Of: Alabama, Alaska, Arkansas, Florida, Georgia, Kentucky, Louisiana, Mississippi, Nebraska, North Carolina, Oklahoma, Oregon, South Carolina, Tennessee, Texas, Virginia, And Washington State, Puerto Rico, And U.s. Virgin Islands). Acquisition Support Is Provided From Srs Headquarters Located In Asheville, Nc And All Files Will Be Located At The Srs Headquarters.
the Database Contains All The Qualified, Interested Ae Firms That Respond To This Notice For Consideration For Future Approved Projects Falling Within The North American Industry Classification System (naics) Codes Indicated. Examples Of Some Of The Types Of Work Includes But Is Not Limited To (approximately 73 Awards Over The Previous 3 Years):
naics Total Awards Total Value
541310 7 $588,300.85
541320 1 $3,400.00
541330 49 $4,329,993.76
541350 1 $5,201.82
541360 1 $94,043.53
541370 8 $243,637.50
541620 2 $109,102.01
541690 1 $57,753.00
541990 1 $32,547.00
replacements, Bridges, Roads, And Trails
surveying (construction And Property)
construction Inspection/safety Inspections Of Roads, Bridges Under Fp-14 And State Laws
design Of Repairs To Small Dams And Impoundments
laboratory Repairs And Renovations
review And Design Of Hvac Systems Upgrades
green Building Construction And Certification Consultation
historic Preservation
renovations To Improve Energy Efficiency And Address Safety Concerns
design Of Small Warehouses And Offices
energy Audits And Studies
design Of Photovoltaic And Other Renewable Energy Systems
review And Design Of Electrical Systems
drafting Services
overall Facility Condition Assessments
geotechnical Investigation, And Environmental (rcra, Cecrla, Cwa, Etc.) Investigations, Reviews, Inventories, Audits, And Coordination Of Rcra And Other Waste Disposal.
there Is An Average Of 100 Firms Listed In Our Database Each Year. On An Annual Basis, An Average Of Twenty Requirements Are Expected To Be Executed Using This Database, Throughout All States Covered.
what Is The Short Selection Process?
the Short Selection Process Utilizes The Procedures Set Forth In Federal Acquisition Regulation (far) Part 36.602-5. For A&e Projects With An Estimated Total Fee Under The Simplified Acquisition Threshold (currently $250,000) Agencies May Review Current Data Files For Eligible Ae Firms, Perform A Technical Review And Evaluation To Determine The Three (3) Most Highly Qualified Firms, And Have Discussions With The Three (3) Firms To Determine The Best Qualified Firm For That Project. A Price Proposal Will Then Be Requested From The Highest Technically Rated Firm. If A Reasonable Price Cannot Be Negotiated, Discussions Will Be Held With The Second-best Qualified Firm, And So On. Ae Data Files Will Be Maintained By State And Naics Code. The Ae's Ability To Provide Licensed Professionals In The State/territory Where The Project Is Located (far 36.602-1(a)(1) And The Firm's Geographic Proximity And Knowledge Of The Local Area (far 36.602-1(a)(5)) As Identified On The Ae's Sf330 And Supplemental Information, Will Be Used For The First Preliminary Screening Of Firms When A Large List Of Potential Firms Exists.
large Businesses Should Not Respond. All Acquisitions Utilizing This Short Selection Database Shall Be Set-aside For Small Business Concerns. The Database Is Set Up With Filters For State, Zip Code, Naics Codes, Small Business Size, And Small Business Socio-economic Classification.
the Due Date Is Listed Below; Sf330s Are Valid For One Year From The Date Of Notification That Your Firm Has Been Added To The Short List Database. Firms Are Encouraged To Update Their Data Annually By Responding To This Announcement. However, The Forest Service Will Retain Previously Submitted Data For A Period Of Three Years. Ae Firms Currently On The Shortlist Will Be Retained On The New Shortlist Unless The Ae Firm’s Data Has Not Been Resubmitted Within Three Years, Or The Ae Firm Responds To The Contracting Officer That They No Longer Wish To Be Included.
what Does My Firm Need To Submit To Determine Eligibility And Receive Consideration For Future Ae Projects?
submittals Shall Be Brief And Concise. Only The First Fifty (50) Pages Of Your Response Will Be Retained. The Initial Review Will Determine If A Firm Is Minimally Qualified To Do Work For The Federal Government As Described In The Synopsis. After Initial Evaluation, Minimally Qualified Firms Will Be Listed In The Short Selection Database And The First 50 Pages Of Their Submittal Package Placed On File.
as Specific Projects Arise, The Short Selection Database Will Be Used To Pull A List Of Qualified Firms That Can Perform The Needed Work At The Specific Location. At That Point, The Submittal Package For Those Specific Firms Will Be Pulled From The File And Used To Perform A Technical Review As Described In The Synopsis.
the Company Submittal Shall Include The Following Information:
cover Letter Should Be Included With All Other Data. The Letter Should Outline The Work Your Firm Specializes In And Include A Brief Description Of Your Firm's Capabilities Specifically Relating To The Project Examples Stated Above. 1 Page Limit – Not Included In 50-page Limit.
attachment A - A&e Submittal Cover Sheet. A-e Firms Do Not Need To Cover All Locations Nor Do They Need To Perform All Naics. Attachment A -a&e Submittal Cover Sheet Allows An Ae Firm To Select Which Location They Can Cover And Which Naics They Are Able To Perform. 2 Pages - Not Included In 50-page Limit.
system For Award Management (sam) Record. A Copy Of Your Current And Active Sam Registration Is Required For Award Of Federal Contracts And To Be Considered For Project Work. All Naics Codes Listed On The A&e Submittal Cover Sheet Must Be Listed On Your Sam Record. Contractors May Register In Sam At Www.sam.gov. Registration Is Free Of Charge To All Government Contractors. - Not Included In 50-page Limit.
attachment B - Sf330, Parts 1 And 2 (6 Pages). Part 2 Of The Sf330 Includes A List Of The Number Of Licensed Professionals And The States Of Their Licensing For Each Of The Function Codes Identified In Block 9 Of Part 2 Of The Sf330. Https://www.gsa.gov/forms-library/architect-engineerqualifications. 50-page Limit Applies. This Includes The Primary Firm And Their Partners/subcontractors.
design Fee Limitations.
in Accordance With Federal Acquisition Regulation (far) 15.404 4(c)(4)(i)(b), Fees For Design Services Cannot Exceed 6% Of The Estimated Construction Cost Amount. See Attachment C For Information On Some Specific Services Subject To/not Subject To The 6% Fee Limitation. This List Is Not Meant To Be All Inclusive. Please Note: Far 36.602-1(a) Requires “professional Qualifications Necessary For Satisfactory Performance Of Required Services” But Does Not Specifically Require That A License Be Held In Every State Included In This Requirement. However, The Respondent Should Be Familiar With Requirements Specific To The Different Locations And Be Available To Travel To The Location For Any Necessary Site Visits.
submittal Information/deadlines.
deadline: Submittals Must Be Received On 15 Mar 2024 By 1200 P.m. Anchorage, Alaska Time.
addressing: All Submittals Will Be Pdf Format And Emailed.
The Subject Line Of Your Email Shall Read: 12445124r0001_company Name_sf330_submittal
how To Submit: Submittals Will Be Emailed To Cynthia.granderson@usda.gov With A Cc: Steven.alves@usda.gov
the Contracting Officer Reserves The Right To Onboard Additional Ae Firms As Part Of Maintaining The Short Selection Database. The Database Will Be Refreshed On An Annual Basis Via Additional Announcements On Beta.sam.gov. Questions Related To This Announcement Shall Be Referred To Steven Alves At Steven.alves@usda.gov
participating Usda States And Forests. Firms Are Encouraged To Visit The Participating Unit Websites To Gain Further Insight Into Their Potential Unique Requirements For Engineering And Design Work:
southern Research Station (srs) - Https://srs.fs.usda.gov/locations/
pacific Northwest Research Station (pnw) - Https://www.fs.usda.gov/research/pnw
international Institute Of Tropical Forestry (iitf) - Https://www.fs.usda.gov/main/iitf
southern Region, Region 8 - Https://www.fs.usda.gov/main/r8
alaska Region, Region 10 - Https://www.fs.usda.gov/main/r10
contact Information
contracting Office Address
daniel Boone National Forest
1700 Bypass Road
winchester, Ky 40391
primary Point Of Contact
cynthia Granderson
cynthia.granderson@usda.gov
601-965-1619
secondary Point Of Contact
steven Alves
steven.alves@usda.gov
859-334-0524
Closing Date15 Mar 2025
Tender AmountRefer Documents
VETERANS AFFAIRS, DEPARTMENT OF USA Tender
Civil And Construction...+1Building Construction
Corrigendum : Closing Date Modified
United States
Details: Scope:provide Construction Services For The Renovate Halls, Walls, And Ceilings Of Ground Floor Building 1 Project, Including Interior Finishes, Hazardous Material Remediation In Sections Of The Ground Floor Construction Space And All Associated Work As Per Attached Plans And Specifications At Durham, Nc Va Medical Center.
background:ground Floor Consists Of Some Original Finishes And Some Refinished Surfaces. Unknown Of Last Renovation Date. The Ground Floor Is Outdated And In Desperate Need Of Renovation And Repair. Pictures And Descriptions Of Existing Conditions Can Be Found In The Drawings And Specifications Provided.
general: Work Includes, But Is Not Limited To Alterations, Architectural, Demolition, Asbestos Abatement, Interior Finishes, Hvac, And Electrical Work, And Certain Other Items To Install New Finishes. Trades Needed To Complete Work Include Hvac, Electrical, Fire Protection, Carpenter, And Any Other Trades Deemed Necessary By The Contractor Will Be Obtained To Complete The Construction As Required By Plans And Specifications. Contractor Shall Completely Prepare Site For Building Operations, Including Demolition And Removal Of Existing Finishes, Remediation Of Substrates To Receive New Finishes, And Installation Of New Finishes In Building 1 On The Ground Floor As Required By Drawings And Specifications.
offers Should Consider The Availability Of Materials And Cost Of Materials For Finishes Prior To Submitting A Bid.
place Of Performance:tasks Will Be Performed At The Va Medical Center, Durham, Nc 27705.
business Hours: Normal Business Hours Are Monday Through Friday From 8am To 4:30pm. Work Will Be Completed Outside Of Normal Business Hours. On Page 26 Of Specs The Allowed Work Hours Are Stated For Each Phase. This Facility Is In Operation 24 Hours A Day, And The Schedule Will Keep The Construction Work To Times Of Lower Traffic.
phasing: Project Construction Will Be Phased As Indicated In Drawings And Specifications. Work Will Be Scheduled To Minimize The Disruption To The Medical Center And Other Contractors.
all Work Is To Be Performed Outside Of Normal Business Hours Unless Otherwise Noted In Construction Documents. Work Shall Be Coordinated With The Va Contracting Officers Representative (cor) In Advance To Minimize Disruption Of Facility Operations. Deviations Or Change Requests To Work Hours Must Be Approved Through The Cor.
no Work Is To Be Performed On Federal Holidays Without Written Permission Of Cor.
utility Outages Shall Be Performed Outside Of Normal Business Hours Unless Approved By The Cor. All Outages Shall Be Scheduled Through The Cor And Approved By The Medical Center Prior To Taking Place. Outages Must Be Requested In Writing A Minimum Of 14 Days In Advance. The Va Has The Right To Cancel All Outages At The Last Moment Without Notice Due To Patient Safety Related Issues, Severe Weather, Electrical Power Outages Or Other Concerns Deemed Important. The Contractor Shall Create, Present, And Have A Cor Approved Work Plan Prior To Commencing With Any Work. Work Plan Shall List All Steps To Be Taken For Removing Each Piece Of Equipment From Service, Steps To Be Taken For Installation, And Steps To Be Taken In Case Of An Emergency.
Closing Date18 Mar 2025
Tender AmountRefer Documents
441-450 of 535 active Tenders