Hvac Tenders
Hvac Tenders
London Borough Of Lewisham Tender
Civil And Construction...+1Building Construction
United Kingdom
Closing Date3 Feb 2025
Tender AmountRefer Documents
Details: Lewisham Council (the Council) Invites You To Submit A Tender For The Levelling Up Fund (luf) Lewisham Library Refurbishment Works. The Refurbishment Works Will Deliver An Improved Library, Archive, Workspace And Hospitality Offering, And Includes But Is Not Limited To, New Insulated Roof, Structural Reinforcements, External Cladding, Windows, Hvac, Lighting, Data, Plumbing, Life Safety Systems, Replacement Lift, Pv Panels, Internal Layout Reconfiguration And Fit-out, Replacement Toilets, New Café And Fixed Bespoke Joinery Including Feature Central Staircase. The Council Intends To Procure A Main Contractor Who Is Able To Evidence Extensive Experience Of Working On High Quality And High Profile Refurbishment Projects On Joint Authority Highways And Within Busy Public Environments. Bidders Must Be Able To Demonstrate A Full Understanding Of The Limitations And Requirements Of Such Buildings When It Comes To Undertaking Planned Refurbishment Works. To Be Considered As A Bidder You Must Complete And Submit A Bid By The Deadline Of 12:00 Noon On 03.02.2025. Please Allow Sufficient Time To Make Your Return, As Tender Submissions Cannot Be Uploaded And Submitted After This Return Deadline. Please Refer To The Contract Particulars And Other Supporting Information For More Details About This Project, Which Can Be Found By Logging In To Www.londontenders.org
VETERANS AFFAIRS, DEPARTMENT OF USA Tender
Others
United States
Closing Date20 Dec 2024
Tender AmountRefer Documents
Details: Amendment No.2
request For Lease Proposal No. 36c10f24r0001 amendment No. 2
to Request For Lease Proposal No. 36c10f24r0001
october _7_, 2024
veterans Affairs
columbia, Mo Research Lease the Following Items Of The Subject Request For Lease Proposal (rlp)
36c10f24r0001 Have Been Amended As Follows And Hereby Enacted
within Rlp Form R100 the Submission Due Date On The Rlp Cover Page Is Deleted And Replaced With The
following: offers Due By _12_/_20_/2024 compliance With Va Hvac Design Manual Section 3.2.1.4 Roof-top Air Handling Units Stating Locations Where Weather Is Extreme, Including Where The Ashrae 99% Heating Design Temperature Is Less Than 10 F (-12 C) Will Not Be Mandatory. ============================================================================================== --------------------------------end Of Rlp Changes------------------------------
all Respondents To This Rlp Shall Acknowledge Receipt Of This Amendment No. 2 By Signing In The Space Provided Below. The Acknowledgement Must Be Received With The Initial Offer. receipt Of Amendment No. 2 Is Hereby Acknowledged: for The Offeror: ______________________
offeror Name (printed) ______________________
offeror Signature ______________________
date
DEPT OF THE NAVY USA Tender
United States
Closing Date13 Jul 2027
Tender AmountRefer Documents
Description: Naval Surface Warfare Center Indian Head Division (nswc Ihd), Located In Indian Head, Maryland, Is Interested In Establishing Blanket Purchase Agreements (bpas) With Companies That Provide Standard Commercial Supplies And Services At Competitive Prices In Classification: bpa Categories Naics Psc remediation Services 562910 hand Tools nbsp;332216 5120 hvac nbsp;326191 4120 x-ray Film 325992 6525 cylinder Gas nbsp;325199 6830 safety Coveralls 315990 8415 containers 321920 8145 electrical/electronic 335999 5999 telecom 334290 court Reporter/arbitrator 541199 nbsp; r606 *patent Services nbsp;541430 R498 *education 611710 u099 *fire Protection 922160 chemicals 325998 facilities Support Service 561210 *patent Services Will Have Subcategories Which Are The Following But Not Limited To: it electrical/electronic mechanical *education Will Have Subcategories Which Are The Following But Not Limited To: leadership employee safety fire Protection Will Have Subcategories Which Are The Following But Not Limited To: sprinkler System fire Alarm/panels bpa Calls Will Not Exceed The Simplified Acquisition Threshold And Offerors Will Compete At The Call Level. interested Companies Must (have/include): documentation Addressing The Capabilities And Bpa Categories Interested In Participating. complete And Return The Price List (attach Your Price List If Applicable). cover Sheet With The Official Company Name, Cage Code, And Point Of Contact Including Name, Phone Number, And Email Address. an Active Account In The Procurement Integrated Enterprise Environment (piee Formerly Wawf) At Https://wawf.eb.mil To Enter Invoices And Receiving Reports, Or Credit Card As A Method Of Payment. an Active Account In System For Award Management (sam Https://www.sam.gov/sam/). itar Certification- Procurements Under These Bpa Masters Include Unclassified Controlled Technical Information Assigned A Restricted Distribution Statement Which Is Export Controlled. To Receive This Unclassified Controlled Technical Information, An Offeror Must Be Currently Certified Through The United States/canada Joint Certification Program. To Become Certified For Receipt Of The Technical Documents, A U.s Offeror Must Submit A Completed Dd Form 2345 To The U.s./canada Joint Certification Office. Canadian Offerors May Submit Either A Completed Dd Form 2345 Or Dss-mas 9379 For Certification. In Addition, A Copy Of The Company's State/provincial Business License, Incorporation Certificate, Sales Tax Identification Form Or Other Documentation Which Verifies The Legitimacy Of The Company Must Accompany All Dd Form 2345s. Additional Information On The Joint Certification Program And A Checklist For Completion Of The Dd Form 2345 Is Available At The Following Website: Http://www.dla.mil/hq/informationoperations/offers/products/logisticsapplications/jcp important Notes: *this Is A Small Business Set-aside However, Large Businesses Will Be Considered For Other Opportunities. If You Possess A Gsa Contract Please Note Your Gsa Contract Number In Your Response. Team Arrangements Are Encouraged. *vendors Who Are Found To Have Technical Merit Will Be Issued A Master Bpa To Be Able To Bid On Future Requirements. *items On The Price List Include Drawing Numbers. Please Provide Your Best Estimate Based On Your Work History. Catalog Prices Can Be Provided As They May Help With Direct Award Under The 10k Threshold. *the Government Reserves The Right To Consider Past Performance Information Available From Other Sources, Including, But Not Limited To, Information In The Contractor Performance Assessment Reporting System (cpars), The Past Performance Information Retrieval System (ppirs Https://www.ppirs.gov), And The Federal Awardee Performance And Integrity Information System (fapiis). the Points Of Contact For This Request Are: dr. David Greaves, At David.greaves@navy.mil michelle Reeves, At Michelle.y.reeves.civ@us.navy.mil marlene Ridgell, At Marlene.l.ridgell.civ@us.navy.mil sarah Hayden, At Sarah.n.hayden3.civ@us.navy.mil jodi Fields, At Jodi.l.fields.civ@us.navy.mil angela Tejeda, At Angela.y.tejeda.civ@us.navy.mil
Qatar Energy Tender
Civil And Construction...+1Civil Works Others
Qatar
Closing Date19 Jan 2025
Tender AmountRefer Documents
Details: Contractor Shall Carry Out The Procurement, Supply, Delivery, Installation, Construction, Pre-commissioning, Commissioning, And Handing Over Of Facility Named As 'new Drilling Support Warehouse And Yard At Rlic' With Total Built Up Area Of Warehouse, Approximate 2600 M2 And Open Storage Yard Area Of Approximate 2200 M2. The Proposed Facility Consists Of The Following: 1.warehouse Building A.,,warehouse Building With Reinforced Concrete Sub-structure And Grade Slab, External Walls, Roofing Works, Internal Walls, Doors, Windows, Louvers, Finishing Works, Storage Racking System And All Accessories As Mentioned In Contract Documents. B.,,building Services Including Lighting, Small Power, Earthing And Lightning Protection, Ups, Ict/elv And Telecom, Cctv, Acs, Hvac, Plumbing, Drainage, Fire And Gas Detection And Alarm System, Fire Protection Systems 2,,external Works And Services Building A.,,outdoor Storage Yard And Internal Access Roads B.,,landscaping And Perimeter Fence And Gate C.,,services Building Comprised Of The Water/irrigation Tank And Pump Room, Electrical Room And Yard For Puss. D.,,site Utilities Including Area Lighting, Cctv, Surface Drainage, Fire Protection, And All Tie-in Works With The Existing Services Networks Including Power, Telecom, Potable Water, Fire Water, Sewage.
Soci T Wallonne De Financement Compl Mentaire Des Infrastructures Tender
Civil And Construction...+2Others, Civil Works Others
Belgium
Closing Date10 Jan 2025
Tender AmountEUR 6.7 Million (USD 7.1 Million)
Details: Title: Marché De Travaux Ayant Pour Objet La Réhabilitation Complète D’un Immeuble De Bureaux Situé Rue Du Canal De L’ourthe, 9/3 À 4031 Angleur
description: Les Bureaux De La Sofico Se Situent Actuellement Dans Un Bâtiment Situé Rue Du Canal De L’ourthe, 9, Bte 3 À B-4031 Angleur. Ce Bâtiment, Érigé Dans Les Années 1990, Ne Répond Plus Aux Normes Et Standards Actuels (incendie, Électricité, Isolation, Chauffage, Bien-être Des Travailleurs, Etc.). Le Présent Marché De Travaux Vise La Réhabilitation Complète De Ce Bâtiment. Les Travaux À Réaliser Sont Essentiellement Les Suivants : - Travaux De Démolition Et De Curage Du Bâtiment Existant En Vue De Sa Réhabilitation ; - Gros Œuvre Et Parachèvement En Vue De La Réhabilitation Du Bâtiment ; - Travaux De Menuiseries Extérieures ; - Installation D’équipements De Techniques Spéciales (hvac Et Électricité) ; - Aménagement Des Abords Et Des Places De Stationnement. Les Travaux Décrits Ci-dessus Ne Sont Pas Exhaustifs. Le Détail Des Travaux Est Repris Dans Les Clauses Techniques Et Le Métré Récapitulatif.
Soci T Wallonne De Financement Compl Mentaire Des Infrastructures Tender
Civil And Construction...+2Others, Civil Works Others
Belgium
Closing Date30 Dec 2024
Tender AmountEUR 6.7 Million (USD 7.1 Million)
Details: Title: Marché De Travaux Ayant Pour Objet La Réhabilitation Complète D’un Immeuble De Bureaux Situé Rue Du Canal De L’ourthe, 9/3 À 4031 Angleur
description: Les Bureaux De La Sofico Se Situent Actuellement Dans Un Bâtiment Situé Rue Du Canal De L’ourthe, 9, Bte 3 À B-4031 Angleur. Ce Bâtiment, Érigé Dans Les Années 1990, Ne Répond Plus Aux Normes Et Standards Actuels (incendie, Électricité, Isolation, Chauffage, Bien-être Des Travailleurs, Etc.). Le Présent Marché De Travaux Vise La Réhabilitation Complète De Ce Bâtiment. Les Travaux À Réaliser Sont Essentiellement Les Suivants : - Travaux De Démolition Et De Curage Du Bâtiment Existant En Vue De Sa Réhabilitation ; - Gros Œuvre Et Parachèvement En Vue De La Réhabilitation Du Bâtiment ; - Travaux De Menuiseries Extérieures ; - Installation D’équipements De Techniques Spéciales (hvac Et Électricité) ; - Aménagement Des Abords Et Des Places De Stationnement. Les Travaux Décrits Ci-dessus Ne Sont Pas Exhaustifs. Le Détail Des Travaux Est Repris Dans Les Clauses Techniques Et Le Métré Récapitulatif.
Vennesla Kommune Tender
Civil And Construction...+2Consultancy Services, Civil And Architectural Services
Norway
Closing Date10 Jan 2025
Tender AmountNOK 52.6 Million (USD 4.7 Million)
Details: Title: Framework Agreement For Technical Assistance/consultancy/consulting Engineers/architects.
description: The Framework Agreement Shall Ensure The Contracting Authority Access To Consultancy And Technical Assistance, With Relevant Competence Within The Following Disciplines: 1. Consultant Engineer For Construction (rib) 2. Consultant Engineer For Fire (ribr) 3. Consultant Engineer For Electro (rie) 4. Consultant Engineer For Hvac (riv) 5. Consultant Engineer For Water Sewage And Surface Water (riva) And Roads 6. Consultant Engineer For Geo Engineering (rig) 7. Consultant Engineer For Energy (rien), And Environmental Consultant (rim) 8. Architect (ark) 9. Area Planning And Development Work 10. Engineering Design Manager And Engineering Design Group Manager (plg) 11. Landscape Architect (lark) The Framework Agreement Will Be Valid For 2 Years, With An Option For The Contracting Authority To Extend The Contract For 1+1 Year. The Contracting Authority Can Announce Individual Competitions For Larger/special Projects. Where Assignments Included In The Descriptions In The Framework Agreement Are Included As Part Of A Larger Project, The Contracting Authority Can, After A Total Assessment In The Specific Case, Decide That The Assignment Can Be Added To Another. For Example, Where A Turnkey Contractor Is Engaged. The Framework Agreement Is Divided Into 11 Sub-contracts, See The Tender Documentation And Requirement Specifications For Further Information.
Caraga State University Tender
Security and Emergency Services
Philippines
Closing Date23 Dec 2024
Tender AmountPHP 2.6 Million (USD 45 K)
Details: Description This Is A 1 Lot Procurement Item 1. Fire Detection & Alarm System (csu-main Ladies & Gents Dormitory) 1. Scope This Specification Covers The Design, Supply, Installation, Testing, And Commissioning Of A Fully Functional Fire Detection & Alarm System (fdas) For Life Safety And Early Fire Detection In A Building. 2. Applicable Standards And Codes • Nfpa 72 – National Fire Alarm And Signaling Code • Nfpa 70 – National Electrical Code • En 54 – European Standards For Fire Detection Systems • Iec 60331 – Fire-resistance Of Electrical Cables • Bs 5839 – Fire Detection And Alarm Systems In Buildings • Iso 7240 – International Standards For Fire Detection And Alarm Systems • Local Codes & Regulations (philippine Fire Code) 3. System Requirements The Fdas Shall Have The Following Key Components: 4. Material: • Fire Alarm System (call Box, Control Panel, • Pull Station / Call Point) • Smoke Detectors, Heat Detectors, Flame Detector 1. Control And Monitoring Panel (facp) O Microprocessor-based Control Unit With Lcd Display. O Supports Both Conventional And Addressable Loop Protocols. O Zone-wise Display Of Alarms And Faults. O In-built Battery Backup For 24 Hours Of Operation. 2. Detectors O Smoke Detectors – Photoelectric Or Ionization Type For Early Detection Of Smoke. O Heat Detectors – Rate-of-rise Or Fixed-temperature Type. O Multi-sensor Detectors – Combination Of Smoke, Heat, And Co Sensing. 3. Manual Call Points (mcp) O Wall-mounted, Break-glass Type. O Provides Manual Activation Of Alarms. 4. Alarm Notification Devices O Sounders And Sirens – Audible Devices Producing 85 Db Or Higher At 3 Meters. O Strobe Lights – Visual Indicators For Noisy Environments Or Areas With Hearing-impaired Individuals. 5. Fire Alarm Interface Modules O Input Modules – For Connecting External Signals (e.g., Sprinkler Water Flow). O Output Modules – For Triggering External Systems (e.g., Fire Doors, Elevators, Hvac Shut-off). 6. Repeater Panel (optional) O Mimics The Status Of The Facp In Remote Locations. 7. Cabling O Fire-resistant, Low-smoke Zero-halogen (lszh) Cables. O Installed In Conduit Or Raceways As Per Nfpa 70. 4. Functional Requirements • Detection And Notification: O The System Shall Automatically Detect Fire, Raise Alarms, And Activate Visual/audible Devices. O Manual Activation Through Mcps. • Supervision: O Continuous Monitoring For Detector Integrity And Wiring Faults. O Automatic Fault Detection And Status Display On The Facp. • Interface With Other Systems: O Hvac Control To Shut Down Air Systems In Fire Events. O Integration With Sprinklers And Fire Suppression Systems. O Elevator Recall For Fire Scenarios. O Emergency Lighting Activation. 5. Power Requirements • Primary Power Supply: O 230v Ac, 50/60hz. • Secondary Power Supply: O Battery Backup Sufficient For 24 Hours Standby And 5 Minutes Of Full Alarm. O Automatic Battery Charging And Switchover. 6. Environmental Conditions • Operating Temperature: 0°c To 49°c (32°f To 120°f) • Humidity: 0 To 93% Rh, Non-condensing 7. Installation Requirements • Install Detectors According To Nfpa 72 Guidelines For Spacing And Placement. • Mcps Should Be Installed Along Escape Routes, At 1.4 Meters From The Floor. • All Alarm Devices Shall Be Mounted At Visible And Accessible Locations. • Proper Labeling And As-built Drawings To Be Provided. 8. Testing And Commissioning • Pre-commissioning Tests: O Check For Wiring Continuity And Insulation Resistance. O Verify Connections Between Detectors, Mcps, And The Control Panel. • Functional Tests: O Test Each Detector For Correct Alarm Activation. O Verify Correct Operation Of Sounders And Strobe Lights. O Test Manual Call Points For Proper Response. • System Integration Tests: O Confirm Proper Interaction With Other Systems (hvac, Elevators, Sprinklers). 9. Documentation Requirements • Operation And Maintenance Manual. • As-built System Drawings. • Test And Commissioning Reports. • Training Documents For System Operators. 10. Warranty And Support • Minimum 1-year Warranty For All System Components. • Availability Of Technical Support And Spare Parts For At Least 10 Years. • Optional: Preventive Maintenance Contract. 11. Safety And Compliance • Compliance With Local Fire Codes And Safety Regulations. • Use Of Certified Detectors And Equipment From Recognized Manufacturers. Item 2. Fire Detection & Alarm System (csucc Ladies & Gents Dormitory) 1. Scope This Specification Covers The Design, Supply, Installation, Testing, And Commissioning Of A Fully Functional Fire Detection & Alarm System (fdas) For Life Safety And Early Fire Detection In A Building. 2. Applicable Standards And Codes • Nfpa 72 – National Fire Alarm And Signaling Code • Nfpa 70 – National Electrical Code • En 54 – European Standards For Fire Detection Systems • Iec 60331 – Fire-resistance Of Electrical Cables • Bs 5839 – Fire Detection And Alarm Systems In Buildings • Iso 7240 – International Standards For Fire Detection And Alarm Systems • Local Codes & Regulations (philippine Fire Code) 3. System Requirements The Fdas Shall Have The Following Key Components: 4. Material: • Conventional Smoke Detector With Base - Sumring/dl Brand – • Conventional Manual Call Point - Sumring/dl Brand • Conventional Fire Bell 6" - Sumring/dl Brand • Conventional Fire Alarm Control Panel (8 Zones)- Sumring/dl Brand • Wires, Cables, And Pvc Conduits (roughing Ins) • Mobilization And Demobilization • Power And Water Consumption • Temporary Facilities (temfacil) • Contingencies • Site Safety And Health (ppes) • Ladders And Scaffolds, Tools And Equipment • Testing And Commissioning 5. Control And Monitoring Panel (facp) O Microprocessor-based Control Unit With Lcd Display. O Supports Both Conventional And Addressable Loop Protocols. O Zone-wise Display Of Alarms And Faults. O In-built Battery Backup For 24 Hours Of Operation. 6. Detectors O Smoke Detectors – Photoelectric Or Ionization Type For Early Detection Of Smoke. O Heat Detectors – Rate-of-rise Or Fixed-temperature Type. O Multi-sensor Detectors – Combination Of Smoke, Heat, And Co Sensing. 7. Manual Call Points (mcp) O Wall-mounted, Break-glass Type. O Provides Manual Activation Of Alarms. 8. Alarm Notification Devices O Sounders And Sirens – Audible Devices Producing 85 Db Or Higher At 3 Meters. O Strobe Lights – Visual Indicators For Noisy Environments Or Areas With Hearing-impaired Individuals. 9. Fire Alarm Interface Modules O Input Modules – For Connecting External Signals (e.g., Sprinkler Water Flow). O Output Modules – For Triggering External Systems (e.g., Fire Doors, Elevators, Hvac Shut-off). 10. Repeater Panel (optional) O Mimics The Status Of The Facp In Remote Locations. 11. Cabling O Fire-resistant, Low-smoke Zero-halogen (lszh) Cables. O Installed In Conduit Or Raceways As Per Nfpa 70. 12. Functional Requirements • Detection And Notification: O The System Shall Automatically Detect Fire, Raise Alarms, And Activate Visual/audible Devices. O Manual Activation Through Mcps. • Supervision: O Continuous Monitoring For Detector Integrity And Wiring Faults. O Automatic Fault Detection And Status Display On The Facp. • Interface With Other Systems: O Hvac Control To Shut Down Air Systems In Fire Events. O Integration With Sprinklers And Fire Suppression Systems. O Elevator Recall For Fire Scenarios. O Emergency Lighting Activation. 13. Power Requirements • Primary Power Supply: O 230v Ac, 50/60hz. • Secondary Power Supply: O Battery Backup Sufficient For 24 Hours Standby And 5 Minutes Of Full Alarm. O Automatic Battery Charging And Switchover. 14. Environmental Conditions • Operating Temperature: 0°c To 49°c (32°f To 120°f) • Humidity: 0 To 93% Rh, Non-condensing 15. Installation Requirements • Install Detectors According To Nfpa 72 Guidelines For Spacing And Placement. • Mcps Should Be Installed Along Escape Routes, At 1.4 Meters From The Floor. • All Alarm Devices Shall Be Mounted At Visible And Accessible Locations. • Proper Labeling And As-built Drawings To Be Provided. 16. Testing And Commissioning • Pre-commissioning Tests: O Check For Wiring Continuity And Insulation Resistance. O Verify Connections Between Detectors, Mcps, And The Control Panel. • Functional Tests: O Test Each Detector For Correct Alarm Activation. O Verify Correct Operation Of Sounders And Strobe Lights. O Test Manual Call Points For Proper Response. • System Integration Tests: O Confirm Proper Interaction With Other Systems (hvac, Elevators, Sprinklers). 17. Documentation Requirements • Operation And Maintenance Manual. • As-built System Drawings. • Test And Commissioning Reports. • Training Documents For System Operators. 18. Warranty And Support • Minimum 1-year Warranty For All System Components. • Availability Of Technical Support And Spare Parts For At Least 10 Years. • Optional: Preventive Maintenance Contract. 19. Safety And Compliance • Compliance With Local Fire Codes And Safety Regulations. Use Of Certified Detectors And Equipment From Recognized Manufacturers. Note: This Is An Early Procurement Activity For F.y. 2025
Ziekenhuis Aan De Stroom ZAS Vzw Tender
Civil And Construction...+1Civil Works Others
Belgium
Closing Date14 Feb 2025
Tender AmountRefer Documents
Details: Title: Zas Augustinus Afwerking En Technieken Nicu Incl. Aanleveren As-built Dossier
description: Afwerking Bouw (incl. Coördinatie-opdracht) En Installatie Technieken Voor De Nieuwe Nicu Afdeling En Het Fertiliteitscentrum Op De Site Zas Augustinus. Het Betreft De Realisatie Van Een Nieuwbouw (waarbij Het Lot Ruwbouw Reeds In Uitvoering Is) Voor De Diensten Nicu En Fertiliteit Binnen Zas. Het Gebouw Bestaat Uit 4 Bouwlagen, Waarbij Op Het Gelijkvloers En De Eerste Verdieping Ca. 3.450 M² Bruto Vloeroppervlakte Voorzien Wordt Voor De Afdeling Nicu En Waarbij Op De Tweede Verdieping Ca. 1.400 M² Bruto Vloeroppervlakte Voorzien Wordt Voor De Afdeling Fertiliteit. De Technische Ruimte Is Geïntegreerd In De Tweede Verdieping En De Kelderverdieping, Waardoor Er Geen Technieken Op Het Dak Dienen Geplaatst Te Worden. De Horizontale Aansluiting Tussen Het Bestaande Gebouw En De Nieuwbouw Verloopt Via Een Glazen Verbindingsgang Op De Drie Niveaus. De Opdracht Is Opgedeeld In Volgende Percelen: Perceel 1 Afwerking Bouw En Vast Meubilair + Coördinatieopdracht Perceel 2 Hvac Perceel 3 Elektriciteit Perceel 4 Sanitair En Brandbestrijding Perceel 5 Medische Gassen En Ln2
421-430 of 461 active Tenders