GOVERNOR CELESTINO GALLARES MULTI SPECIALTY MEDICAL CENTER Tender
GOVERNOR CELESTINO GALLARES MULTI SPECIALTY MEDICAL CENTER Tender
Costs
Summary
Invitation To Bid For Supply, Delivery, Installation, Testing And Commissioning Of 4 Lots Various Medical Equipment (batch 1) For Gov. Celestino Gallares Multi-specialty Medical Center , Medical And Dental Equipment ,governor Celestino Gallares Multi-specialty Medical Center
Description
Description Gov. Celestino Gallares Multi-specialty Medical Center Invitation To Bid For Supply, Delivery, Installation, Testing And Commissioning Of 4 Lots Various Medical Equipment (batch 1) For Gov. Celestino Gallares Multi-specialty Medical Center 1. The Gov. Celestino Gallares Multi-specialty Medical Center (gcgmsmc), Through The Health Facilities Enhancement Program 2024 Intends To Apply The Sum Of Ninety-eight Million One Hundred Thousand Pesos Only (php98,100,000.00) Being The Abc To Payments Under The Contract For Cb-2024-10-0001. Bids Received In Excess Of The Abc Shall Be Automatically Rejected At Bid Opening. The Gcgmsmc, Through The Health Facilities Enhancement Program 2024 Intends To Apply The Sum Of Ninety-eight Million One Hundred Thousand Pesos Only (php98,100,000.00) Being The Abc To Payments Under The Contract For Each Lot/item.et Al. Lot No. Item/description Quantity Unit Cost Total Cost 1 Bed/s, Hospital, Manual 80 95,000.00 7,600,000.00 2 Advanced Perfusion System, Cardiopulmonary Bypass Pump + In-line Blood Gas Monitoring Device 1 23,000,000.00 23,000,000.00 3 Infusion And System Monitoring 1 37,500,000.00 37,500,000.00 4 Ventilator, Mechanical 15 2,000,000.00 30,000,000.00 Grand Total 98,100,000.00 Bids Received In Excess Of The Abc For Each Lot Shall Be Automatically Rejected At Bid Opening. 2. The Gcgmsmc, Now Invites Bids For The Above Procurement Project. Delivery And Installation Of The Goods Is Required Within 120 Calendar Days Upon Receipt Of Notice To Proceed. Bidders Should Have Completed, Within 3 Years From The Date Of Submission And Receipt Of Bids, A Contract Similar To The Project. The Description Of An Eligible Bidder Is Contained In The Bidding Documents, Particularly, In Section Ii (instructions To Bidders). 3.bidding Will Be Conducted Through Open Competitive Bidding Procedures Using A Non Discretionary “pass/fail” Criterion As Specified In The 2016 Revised Implementing Rules And Regulations (irr) Of Republic Act (ra) No. 9184. A. Bidding Is Restricted To Filipino Citizens/sole Proprietorships, Partnerships, Or Organizations With At Least Sixty Percent (60%) Interest Or Outstanding Capital Stock Belonging To Citizens Of The Philippines, And To Citizens Or Organizations Of A Country The Laws Or Regulations Of Which Grant Similar Rights Or Privileges To Filipino Citizens, Pursuant To Ra No. 5183. 4. Prospective Bidders May Obtain Further Information From Gcgmsmc Through Electronic Mail Via Procurement@cpspecialtycenter.org Or Through The Cellular Number 09209437250. 5.a Complete Set Of Bidding Documents May Be Acquired And Downloaded By Interested Bidders From Gcgmsmc Google Drive From (procurement@cpspecialtycenter.org) On October 21- November 12, 2024 And Upon Payment Of The Applicable Fee For The Bidding Documents, Pursuant To The Latest Guidelines Issued By The Gppb, In The Amount Indicated Below In Accordance With The Following Schedule: Lot No. Item/description Total Cost Bidding Documents Fee (in Philippine Peso) 1 Bed/s, Hospital, Manual 7,600,000.00 10,000.00 2 Advanced Perfusion System, Cardiopulmonary Bypass Pump + In-line Blood Gas Monitoring Device 23,000,000.00 23,000,000.00 3 Infusion And Monitoring System 37,500,000.00 25,000.00 4 Ventilator, Mechanical 30,000,000.00 25,000.00 The Procuring Entity Shall Allow The Bidder To Present Its Proof Of Payment For The Fees Through Online Banking Or Online Deposit With The Following Bank Details: Bank Name: Development Bank Of The Philippines Account Name: Gcg Multi-specialty Medical Complex Account Number: 00-0-15490-780-5 "for Bidders Choosing To Pay Via Online Transfer Or Bank Deposit, Please Ensure That Proof Of Your Successful Transaction Is Promptly Sent To The Procurement Email Address: Procurement@cpspecialtycenter.org. In Compliance With Coa Circular Number 2021-014, Clause 5.2, An Acknowledgement Receipt Will Be Issued As Proof Of Verified And Received Payment. Access To Bidding Documents Will Be Granted Only Upon Presentation Of This Acknowledgement Receipt. 6. The Gcgmsmc Will Hold A Pre-bid Conference On The 30th Day Of October 2024 At 0900h At Meeting Room 1 Located At The 3rd Floor Of Gcgmsmc Building C, Malayo Sur, Cortes, Which Shall Be Open To Prospective Bidders. 7. Bids Must Be Duly Received By The Bac Secretariat Through Manual Submission On Or Before The 12th Day Of November 2024 At 0900h At Gcgmsmc Procurement Office Room 3c-w327 Located At The 3rd Floor Of Gcgmsmc Building C, Malayo Sur, Cortes, Bohol Late Bids Shall Not Be Accepted. 8.all Bids Must Be Accompanied By A Bid Security In Any Of The Acceptable Forms And In The Amount Stated In Itb Clause 14. 9. Bid Opening Shall Be On The 12th Day Of November 2024 At 0900h At Meeting Room 1 Located At The 3rd Floor Of Gcgmsmc Building C, Malayo Sur Cortes. Bids Will Be Opened In The Presence Of The Bidders’ Authorized Representatives Together With Their Company Id. 10.the Gcgmsmc Reserves The Right To Reject Any And All Bids, Declare A Failure Of Bidding, Or Not Award The Contract At Any Time Prior To Contract Award In Accordance With Sections 35.6 And 41 Of The 2016 Revised Irr Of Ra No. 9184, Without Thereby Incurring Any Liability To The Affected Bidder Or Bidders. 11. For Further Information, Please Refer To: Mary Grace L. Simbajon Procurement Office Malayo Sur, Cortes, Bohol Procurement@cpspecialtycenter.org +639209437250 Jessa O. Quiñal Procurement Office Malayo Sur, Cortes, Bohol Procurement@cpspecialtycenter.org +639452478632 October 18, 2024 (signed) Doreen A. Lugo, Lpt Bac Chairperson (signed) Laurence R. Tirol, Md, Fpcp Medical Center Chief I Head Of Procuring Entity -.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.- Item No.: 1 Item Description: Bed/s, Hospital, Manual Unit: Lot Qty: 80 Unit Cost: 95,000.00 Total Cost: 7,600,000.00 Description: Bed/s, Hospital, Manual Size: 2100-2200 (l) X 1000-1100 (w) Millimeters (mm) Mattress Platform: 1800-2000 (l) X 850-950 Millimeters (w) (mm), At Least Four (4) Pieces Mattress, Polyurethane, Four-sectional, Waterproof And Fire Retardant Cover, Thickness At Least 100 Millimeters (mm), At Least One (1) Piece Height, Maximum Height Adjustment 400-800 Millimeters (mm) (+- 10 Degrees) Working Load: 250-300 Kilograms (kg) Backrest Adjustment: 0-80 Degrees (+- 10 Degrees) Knee/leg/thigh Rest Adjustment: 0-35 Degrees (+- 10 Degrees) Cranks, Manual, At Least 3 Pieces, Retractable Casters, At Least Double Sides, 4-6 Inches, Central Locking, At Least 4 Pieces Central Locking Pedal, At Least 2 Pieces Intravenous Fluid (iv) Pole, Stainless Steel, At Least 1 Set With At Least 4 Hooks, Bearing Load 12-15 Kilograms, With Inner Spring, Outer Pipe Diameter 16-20 Mm, Inner Pipe Diameter 16-20 Mm Iv Pole Provision Holes, At Least 4 Pieces Drainage Hook, Mobile, At Least 2 Pieces Trendelenburg 0-20 Degrees, Reverse Trendelenburg 0-20 Degrees Boards, Head & Foot, Curved, Removable, Reversible, Material: Polypropylene, With Automatic Safety Lock, At Least 1900 X 900 Millimeters (mm) Bed Surface, Coated Steel With Epoxy Painting, Anti-bacterial Bed Frame, Low-carbon Square Tube Bed Base, 360-degree Smooth Welding, Made Of 5-6 Millimeter Stamped Rotating Plate Side Rail, With Tuck Away Mechanism, 2 Pieces At Least 950 L X 320 H Mm And 2 Pieces At Least 640 L X 320 H Mm Angle Indicator, Indicates Back Plate Angle Plastic Material Must Be Virgin Acrylonitrile Butadiene Styrene (abs),can Be Sterilized Up To 100 Degrees Celsius Compliant To En60601 Safety Standard Particulars Vendor Shall Warrant That The Product Supplied Shall Equal The Published Specifications. Vendor Shall Provide No Less Than Seven (7) Years Warranty On The System/equipment For Spare Parts And Service Upon Acceptance By End User/s. Vendor Agrees To Provide Free Of Charge All Parts And Labour Necessary To Repair The System During The Period Covered By The Warranty And Replacement Of Any Item/s And/or Part/s Found To Be Defective In Material Or Workmanship Under Normal Use. Vendor Must Conduct Quarterly Preventive Maintenance Program Or Frequently As Recommended By Principal / Manufacturer. Vendor Agrees To Add Equipment Down-time (in Number Of Days) To Total Warranty Period. Vendor Must Respond With Technical Support Staff, Either Remotely Or In-person Where Applicable, Within At Least Twenty-four (24) Hours Upon Notification Of End-user; And Must Perform Corrective Maintenance Within A Maximum Of Fourteen (14) Days Upon Notification Of End-user; Equipment Shall Be Delivered With At Least One (1) Copy Of All Service Manuals And At Least One (1) Copy Of All User Manuals. Equipment Shall Be Delivered Complete With All Cabling, Connectors, Junction Boxes, Mounting Hardware, And All Other Accessories Necessary For Full Operation Of The System/equipment, Where Applicable. Vendor Must Certify That All Products Quoted Must Be In Current Production And Publicly Available As Of The Date Of This Tender. Unproven Future Products Shall Not Be Accepted. All Desired Features Listed Must Be In Current Production, Installed And In Use At The Time Of Quote/bid Any And All Components Not Manufactured By The Vendor/primary Manufacturer Shall Be Listed As Such With Name/address/contact Information Of The Manufacturer Supplied Devices Must Meet All Currently Applicable Safety Standards, Local And International Where Applicable. Vendor Shall Confirm And Certify In Writing That Parts And Labor Will Be Available For The Quoted System For Not Less Than Five (5) Years After The Warranty Period Vendor Shall Agree To Provide Factory Or Principal Manufacturer Training And/or Certification For At Least One (1) In-house Biomedical Technologist Or Engineer And/or Other End User. Vendor May Include Post-warranty Comprehensive Preventive Maintenance Program Proposal For The Next 3-4 Years And Must Also Indicate Cost Estimates For Major Spare Part/s Vendor To Shoulder Any Expenses Related To Delivery, Installation, Commissioning, Permit/s, Training And Other Sundries Necessary For The Complete Installation Of The Equipment Vendor Must Have Available Technical Staff And/or Office/s Within The Region Principal’s / Manufacturer’s Products Must Have Been Present In The Local Market For The Past Five (5) Years Progress Billing And Payment May Be Availed By The Winning Bidder As Follows, Otherwise, Full Payment Is Due At The Completion Of The Project And Requirements: 15% Upon Delivery At Site; 30% Upon Complete Installation, And 55% Upon Completion Of Project And/or Acceptance Of End-user. Completion Period For Delivery Must Not Exceed 120 Calendar Days And Succeeding Installation Must Not Exceed 120 Calendar Days. Any Deviation From This Limit Requires Prior Approval By The Head Of The Procuring Entity (hope) And Only Applies During Extenuating Circumstances. -.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.- Item No.: 2 Item Description: Advanced Perfusion System, Cardiopulmonary Bypass Pump + In-line Blood Gas Monitoring Device Unit: Lot Qty: 1 Unit Cost: 23,000,000.00 Total Cost: 23,000,000.00 Description: Advanced Perfusion System, Cardiopulmonary Bypass Pump + In-line Blood Gas Monitoring Device Heart & Lung Machine With Integrated Centrifugal Pump Built In Centrifugal Pump With The Following Specifications: Controls And Monitor Must Be Mounted To The Machine Drive Unit Must Allow For Interchangeable Components (must Have Flexible Drive Unit For Better Handling) Remote Control Display Panel Must Include The Centrifugal Status And Alarms Flow Sensor Must Be Non-invasive Type One (1) Integrated Centrifugal Pump Plus Either (a) Three (3) Singular Large Pumps + Two (2) Single Small Roller Pump Or (b) A Total Of Five (5) Roller Pumps With Flat Screen Monitor For Heart & Lung Machine Functionality Display Roller Pump Must Have Tubing Clamp Assembly. Must Be A Rotatable Pump Head. With Hand Crank Intended For Manual Use In The Event Of Power Failure For Both Roller And Centrifugal Pump With Complete Safety Mechanism Device. Dual Pressure Module Sensor With Two (2) Cable Pressure Intended For Arterial Cardioplegia Digital Pressure Monitoring And Two (2) Manometer For Manual Monitoring. One (1) Temperature Module With At Least Two (2) Channels Level Sensor And Air Bubbles Sensor Intended For Adult And Pedia Circuits That Will Trigger The Machine To Temporarily Stop Avoiding Air Introduction To Patient With Mechanical Gas Blender For Oxygen And Compressed Air With Hose And Accessory Connectors Inclusion Of Vacuum Regulator Device Halogen Or Led Console Lamp With Flexible Arms Back-up Battery Which Can Provide Power For At Least 1hour Must Provide Six (6) Pieces Of Tubing Clamp With Guard Can Be Powered By 230v ±10, 60hz With Four Heavy Duty Rolling Wheels And Non-scratching With Lock System Included In-line Blood Gas Monitoring Device The Machine Must Be Capable Of A Continuous Determination Of The Following Tests While On Cardiopulmonary Bypass (cpb): Blood Gas (ph, Pco2, Po2, Hco3, Be, So2) Electrolytes & Hematology (k+, Hgb, Hct) Patient Temperature Oxygen Deliver (do2) Inclusion Of Battery Pack To Ensure Uninterrupted Operation. Capable Of Displaying Alert/alarm Indicator When Parameters Fall Outside The Normal Values Must Be Lcd Or Led Screen Machine Must Be Portable And Fit With The Provided Pole Clamps/bracket For Monitoring In The Heart Lung Machine Cable Head Sensor For Testing Must Be Capable For Arterial Or Venous Sampling Monitoring Built-in Printer For Documentation Of Displayed Values With Three Rolls Of Thermal Paper. 60 Hertz Machine Electrical Requirement In-line Blood Gas Monitoring Device One (1) Temperature Module With At Least Two (2) Channels Heater Cooler Machine, At Least Two (2) Umit/s Must Have At Least Two (2) Independent Circuits Intended Either For: A. Oxygenator Heat Exchangers And B. Patient Blankets One (1) Pair Of Hose With Corresponding Connectors For Each Independent Circuit Per Unit Can Be Powered By 230v ±10, 60hz Particulars Vendor Shall Warrant That The Product Supplied Shall Equal The Published Specifications. Vendor Shall Provide No Less Than Five (5) Years Warranty On The System/equipment For Spare Parts And Service Upon Acceptance By End User/s. Vendor Agrees To Provide Free Of Charge All Parts And Labour Necessary To Repair The System During The Period Covered By The Warranty And Replacement Of Any Item/s And/or Part/s Found To Be Defective In Material Or Workmanship Under Normal Use. Vendor Must Conduct Quarterly Preventive Maintenance Program Or Frequently As Recommended By Principal / Manufacturer. Vendor Agrees To Add Equipment Down-time (in Number Of Days) To Total Warranty Period. Must Provide Back-up Immediately Upon Notification Where Applicable. Vendor Must Respond With Technical Support Staff, Either Remotely Or In-person Where Applicable, Within At Least Twenty-four (24) Hours Upon Notification Of End-user; And Must Perform Corrective Maintenance Within A Maximum Of Fourteen (14) Days Upon Notification Of End-user; System/equipment Shall Be Delivered With At Least One (1) Copy Of All Service Manuals And At Least One (1) Copy Of All User Manuals. System/equipment Shall Be Delivered Complete With All Cabling, Connectors, Junction Boxes, Mounting Hardware, And All Other Accessories Necessary For Full Operation Of The System/equipment, Where Applicable. Vendor Must Certify That All Products Quoted Must Be In Current Production And Publicly Available As Of The Date Of This Tender. Unproven Future Products And Model/s Nearing And/or At The End-of-cycle Shall Not Be Accepted. All Desired Features Listed Must Be In Current Production, Installed And In Use At The Time Of Quote/bid; Any And All Software Necessary To Technically Support The System Shall Be Included Any And All Components Not Manufactured By The Vendor/primary Manufacturer Shall Be Listed As Such With Name/address/contact Information Of The Manufacturer Supplied Devices Must Meet All Currently Applicable Safety Standards, Local And International Where Applicable. Vendor Shall Confirm And Certify In Writing That Parts And Labor Will Be Available For The Quoted System For Not Less Than Five (5) Years After The Warranty Period Vendor Shall Agree To Provide Factory Or Principal Manufacturer Training And/or Certification For At Least One (1) In-house Biomedical Technologist Or Engineer And Other Technical Staff (end-user/s); Vendor May Include Post-warranty Comprehensive Preventive Maintenance Program Proposal For The Next 3-4 Years And Must Also Indicate Cost Estimates For Major Spare Part/s Vendor To Shoulder Any Expenses Related To Delivery, Installation, Commissioning, Permit/s, Training And Other Sundries Necessary For The Complete Installation Of The Equipment Vendor Must Have Available Technical Staff And/or Office/s Within The Region Vendor Must Have An Existing / Active Quality Management System Certification E.g. Iso 13485 And/or Iso 9001 Principal’s / Manufacturer’s Products Must Have Been Present In The Local Market For The Past Ten (10) Years, May Provide Certification Where Applicable Progress Billing And Payment May Be Availed By The Winning Bidder As Follows, Otherwise, Full Payment Is Due At The Completion Of The Project And Requirements: 15% Upon Delivery At Site; 30% Upon Complete Installation, And 55% Upon Completion Of Project And/or Acceptance Of End-user. Completion Period For Delivery Must Not Exceed 120 Calendar Days And Succeeding Installation Must Not Exceed 120 Calendar Days. Any Deviation From This Limit Requires Prior Approval By The Head Of The Procuring Entity (hope) And Only Applies During Extenuating Circumstances. -.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.- Item No.: 3 Item Description: Infusion And System Monitoring Unit: Lot Qty: 1 Unit Cost: 37,500,000.00 Total Cost: 37,500,000.00 Description: Supply, Delivery, Installation, Testing & Commissioning Of Infusion & Monitoring System Pump, Volumetric Infusion Docking Station/s Central Monitoring System Mri-compatible Infusion System Oximetry Monitoring System, Non-invasive Pump, Infusion Volumetric, 150 Units Size Less Than Or Equal To 210 (l) X 140 (w) X 73 (h) Millimeters (mm) Weight Less Than Or Equal To 1700 Grams (g) Screen Must Be At Least Three (3) Inches, Touchscreen, Thin Film Transistor (tft) Color Liquid Crystal Display (lcd), At Least 200 X 400 Pixel/s, Adjustable Brightness Levels Display Must Show The Following Information At Least: Infusion Status With Drug/s Name, Infusion Parameter/s, Real-time In-line Pressure; System Status Information With Infusion Mode, Intravenous Set Brand Or Bed Number, Alarm Symbol/s, Battery Status, Network Status, Relayed Status, And System Time; Must Show Infusion Status Indicator On The Door Accuracy : ≤ ± 4.5% Mode/s : Rate Mode, Dose Mode, Dose Time Mode, Time Mode, Sequential Mode, Intermittent Mode, Loading Dose Mode, Ramp Mode, Micro-infusion Mode And/or Drip Mode Must Support The Following Application/s : Intravenous Drug Infusion, Enteral Nutrition Feeding, And/or Blood Transfusion Flow Rate/s: 0.10-2300 Milliliter/s (ml) Per Hour (hr) And/or 0.10-2000 Ml/hr Increment/s: 0.10 Ml/hr (0.10-99.99 Ml/hr), 0.1 Ml/hr (100-999.9 Ml/hr), 1 Ml/hr (100-2300 Ml/hr) Preset Time/s: 00:00:01-99:59:59 Preset Volume: 0.10-9999.99 Ml With Increments Of 0.01 Ml Accumulated Volume: 0.00-9999.99 Ml “keep Vein Open”: (kvo): 0.1-5.0 Ml/hr With Increment/s Of 0.01 Ml/hr Purge Rate: 0.1-2300 Ml/hr Bolus Rate: 0.1-2300 Ml/hr, Automatic Or Manual Occlusion Detection: 50-1125 Millimeters Mercury (mmhg) With At Least 15 Selectable Levels Such As 50, 150, 225, 300, 375, 450, 525, 600, 675, 750, 825, 900, 975, 1050, 1125 Mmhg); With Default Of 450 Mmhg; Pre Alarm Pops Up While Pressure Is Increasing; Auto-restart Capability Where On/off And Restart The Infusion When Occlusion Pressure Is Reduced; Pressure Unit/s Available Such As, Millimeters Mercury (mmhg), Kilo Pascal/s (kpa), Bar, And/or Pounds Per Square Inch (psi) Air Bubble Detection, With At Least Six (6) Level/s, 15, 50, 100, 250, 500, 800 Microliter/s; Air Accumulation 0.1-1.0 Ml Per 15 Minutes Dose Rate Unit/s Must Include The Following: Ng/kg/min, Ng/kg/hr, Ng/kg/24h; Ug/kg/min, Ug/kg/h, Ug/kg/24h, Mg/kg/min, Mg/kg/h, Mg/kg/24h; Mu/kg/min, Mu/kg/h, Mu/kg/24h; U/kg/min, U/kg/h,u/kg/24h; Ku/kg/min, Ku/kg/h, Ku/kg/24h; Eu/kg/min, Eu/kg/h, Eu/kg/24h; Mmol/kg/min,mmol/kg/h, Mmol/kg/24h; Mol/kg/min, Mol/kg/h, Mol/kg/24h; Mcal/kg/min, Mcal/kg/h, Mcal/kg/24h; Cal/kg/min, Cal/kg/h, Cal/kg/24h; Kcal/kg/min, Kcal/kg/h, Kcal/kg/24h; Meq/kg/min, Meq/kg/h, Meq/kg/24h; Auto Lock Time: 1-5 Minute/s Range With On/off Switch Drug Library Up To 5000 Drug/s, 30 Categories, Support For Color-coding History Log Up To 3500 Event/s Volume Collection Available In At Least 4 Method/s Including, 24 Hour Total, Current Total, Period, Timing Volume, Support History Rate Review Dose Error Reduction System Available Definition Of Dose Limit/s Automatic Alarm/s When Reaching Dose Limit/s Intravenous (iv) Administration Set Must Be Able To Accept Universal Iv Set/s Alarm/s Audible And Visual Alarm/s; Sound Volume Adjustable At Least Eight (8) Level/s 2 Level/s: High : Air In Line, Accumulated Air, Empty, Drop Error, Upstream Occlusion, Downstream Occlusion, Infusion Set Disengaged, No Infusion Tube, Infusion Set Error, No Drop Sensor, Battery Depleted, Volume To Be Infused (vtbi) Complete, Kvo Finish, Relay Invalid And/or System Error 2 Level/s: Low: Kvo Running, Battery In Use, Battery Error, Cms/egw Disconnected, Standby Time Expired, Dock Connection Interrupted, System Time Error, Relay Invalid Soon, Time Near End, Reminder And/or Low Battery Reminder: 1-5 Minute/s, On/off Switchable Connectivity Communication Wired And Wireless Usb Support Drug Library Import, Patient Data Import/export, History Record Export, Calibration Date Import/export; Multifunction Connector : Rs232, Nurse Call Connector, Dc Adapter Integration : Connect With Infusion Central Station, Connect With Central Monitoring System Battery Operating Time: More Than Or Equal To Five (5) Hour/s At 25 Ml/hr Charging Time: Less Than Or Equal To Five (5) Hour/s To Full Capacity Power Supply Voltage 100-240 Volt/s, Frequency 50-60 Hertz, (hz), Current 0.5-0.12 Ampere/s (a) Work Environment Operating Temperature: 5 To 40 Degrees Celsius; Storage Temperature -30 To 70 Degrees Celsius; Operating Relative Humidity: 15 To 95%; Storage Humidity 10 To 95%; Operating Atmospheric Pressure: 57 To 107 Kilopascal (kpa); Storage Atmospheric Pressure 15 To 107 Kpa Level Of Resistance To Water And Dust At Least Ingress Protection Rating 33 (ip33) Classification Type Cf Class 1 Docking Station, 40 Units Size 270 (l) X 170 (w) X 390 (h) Millimeters (mm) Weight: Less Than Or Equal To 3900 Grams Display Screen At Least Three (3) Inches Organic Light Emitting Diode (oled) At Least 265 X 64 Pixels Resolution Showing The Following Information: Bed Number, Patient Name, Battery Status, Network Status, Total Volume For 24 Hours; Must Be Able To Connect Via Hl7 Protocol And Integrate With Hospital Information System/s And/or Electronic Medical Record/s Via Wired Or Wireless Protocol; Usb Support For Drug Library Importation, Patient Information Loading, Patient Data Export, History Record And/or Barcode Reader Connection Multifunctional Connector Rs232 And/or Nurse Call Connector Integration Capability To Synergise/connect With Patient Monitor, Connect With Infusion Central Station, And/or Connect With Central Monitoring System Night Mode Capability With On/off, Start Time, End Time And Sound Volume Adjustable History Record Up To 2500 Mounting Type For Horizontal And Vertical Pole Clamp: Horizontal Diameter Range 10 To 25 Mm; Vertical Diameter Range 15 To 40 Mm; One Pole Clamp Per Shelf Module Programmable Mode : Support Automatic Multi-channel Relay Maintenance : Support 2 To 24 Pumps Tool Free Assembly, Support Batch Calibration, Drug Library Import, And Software Upgrade/s Classification Type Cf Class 1 Ip33 Power Supply Battery: Lithium-ion 2500mah Operating Time Of At Least 2 Hours Charging Time At Most 6 Hours Ac Power: 100 To 240 V, 50 To 60 Hertz, 8 To 3.4 A Work Environment Operating Temperature: 5 To 40 Degrees Celsius; Storage Temperature -30 To 70 Degrees Celsius; Operating Relative Humidity: 15 To 95%; Storage Humidity 10 To 95%; Operating Atmospheric Pressure: 57 To 107 Kilopascal (kpa); Storage Atmospheric Pressure 16 To 107 Kpa Level Of Resistance To Water And Dust At Least Ingress Protection Rating 33 (ip33) Classification Type Cf Class 1 Alarm/s Audible And Visual Alarm/s 2 Level/s: High : Battery Depleted, System Error 2 Level/s: Low: Slave Controller Abnormal, Battery In Use, Low Battery, Battery Error, Local Area Network (lan) Internet Protocol (ip) Address Conflict, Wireless Lan Address Conflict, Cms, Egw Disconnect Central Monitoring System System Component/s : Central Station System Center Which Connects Bedside Device/s Hardware: Display/s At Least 27 Inch Tft Lcs Screen/s Medical Grade, At Least Dicom 14, At Least Ip54 Rating Iec 60601, Touch Screen; Must Include Printer/s, Keyboard/s, Mouse/s And Speaker/s Main System Software Specification/s: Number Of Device Up To 64 Patient Monitor/s And Infusion Pump/s Per Station Alarm: Category : Physiological Alarm, Technical Alarm And System Prompt Remote Control : Alarm Switch, Alarm Limits, Alarm Priority, Alarm Pause And Alarm Reset Alarm Analysis : Support Alarm Statistics Trend Review : At Least 240 Hours; Full Disclosure At Least 240 Hours; Data Interface Connection Interface Integrated Egateway Or Standalone Egateway Mri Compatible Infusion System, 1 Unit Size Less Than Or Equal To 560 (l) X 540 (w) X 1540 (h) Mm Including Trolley, Excluding Iv Pole Weight Less Than Or Equal To 50 Kilograms Without Pump/s Display Screen At Least 3 Inches, Oled, 256 X 64 Pixels, Showing The Following Information: Bed Number, Patient Name, Battery Status, Network Status, Total Volume For The Past 24 Hours Infusion Of The Pump; Compatible Pumps At Least 4 Infusion Or Syringe Pumps Mri Scanner Compatibility For Both 1.5 And/or 3.0 Tesla Model/s Alarm/s Audible And Visual Alarm/s 2 Level/s: High : Battery Depleted, Magnet Indicator Battery Depleted, System Error 2 Level/s: Low: Low Battery, Magnet Indicator, Battery Low, Battery Error, Lan Ip Address Conflict, Wlan Ip Address Conflict, Network Disconnected Magnet Indicator : Magnetic Field To Be Used In Magnetic Fields Up To 20 Mt; < 20 Mt Green; 20-40 Mt Yellow; > 40 Mt Red; Connectivity Communication Wired And Wireless Usb Support Drug Library Import, Patient Data Import/export, History Record Export, Calibration Date Import/export, System Upgrade Integration : Synergy With Patient Monitor, Connect With Infusion Central Station, Connect With Central Monitoring System Material : Shielded Aluminum Housing, Ingress Protection Level Ip33 Safety Standards En 60601-1:2006 / A1:2013; En 60601-1-2:2015; En 60601-1-8:2007/a11:2017; F2025-15; F2182-19; F2213-17; F2503-20; Classification Type Cf Class 1 Power Supply Battery: Lithium-ion 3400mah; Ac Power: 100 To 240 V, 50 To 60 Hertz, 8 To 3.4 A Dock: Operating Time At Least 10 Hours; Charging Time At Most 6 Hours Magnet Indicator : Operating Time Of At Least 720 Hours; Recharging Time At Most 8 Hours Work Environment Operating Temperature: 5 To 40 Degrees Celsius; Storage Temperature: -30 To 70 Degrees Celsius; Operating Relative Humidity: 15 To 90%; Storage Humidity: 10 To 95%; Operating Atmospheric Pressure 57 To 107 Kilopascal (kpa); Storage Atmospheric Pressure 16 To 107 Kpa Oximetry Monitoring And Connectivity System, 1 Unit Expendable Patient Monitoring And Connectivity Hub That Integrates An Array Of Technologies, Devices, And Systems To Provide Multimodal Monitoring And Connectivity Solutions In A Single Clinician-centric Platform Regional Oximetry, Non-invasive Pulse Oximetry Display Resolution At Least 1280 X 800 Pixels, At Least 10 Inches Diagonal Size, Multi-touch Touchscreen; Customizable Multiple Screen Views To Feature The Most Applicable Data; Can Display Tissue Oxygen Saturation Of Specific Area; Can Display The Difference Between Current Rso2 And User Defined Baseline; Can Display The Difference Between Rso2 And Spo2; Pulse Rate; Perfusion Index; Pleat Variability Index; High-resolution Plethysmograph Waveform And/or Can Display Spectrogram Representing Activity For Both Sides Of The Brain; Must Have Ports Or Docks That Are Compatible To Plug And Play Modules For The Measurement Of Brain Function Monitoring, Regional Oximetry, And Non-invasive Pulse Oximetry Battery Capacity Is At Least Four Hours Module/s: Cerebral Oximetry At Least One, Pulse Co-oximetry At Least One Can Be Used As Bedside, Handheld And/or Transport Monitor Configurable Parameter And Alarm Settings By Patient Population Audible And Visual Alarms For Quick Identification Of Alarming Parameters With Redundant Speaker System. Particulars Vendor Shall Warrant That The Product Supplied Shall Equal The Published Specifications. Vendor Shall Provide No Less Than Five (5) Years Warranty On The System/equipment For Spare Parts And Service Upon Acceptance By End User/s. Vendor Agrees To Provide Free Of Charge All Parts And Labour Necessary To Repair The System During The Period Covered By The Warranty And Replacement Of Any Item/s And/or Part/s Found To Be Defective In Material Or Workmanship Under Normal Use. Vendor Must Conduct Quarterly Preventive Maintenance Program Or Frequently As Recommended By Principal / Manufacturer. Vendor Agrees To Add Equipment Down-time (in Number Of Days) To Total Warranty Period. Vendor Must Respond With Technical Support Staff, Either Remotely Or In-person Where Applicable, Within At Least Twenty-four (24) Hours Upon Notification Of End-user; And Must Perform Corrective Maintenance Within A Maximum Of Fourteen (14) Days Upon Notification Of End-user; System/equipment Shall Be Delivered With At Least One (1) Copy Of All Service Manuals And At Least One (1) Copy Of All User Manuals. System/equipment Shall Be Delivered Complete With All Cabling, Connectors, Junction Boxes, Mounting Hardware, And All Other Accessories Necessary For Full Operation Of The System/equipment, Where Applicable. Vendor Must Certify That All Products Quoted Must Be In Current Production And Publicly Available As Of The Date Of This Tender. Unproven Future Products Shall Not Be Accepted. All Desired Features Listed Must Be In Current Production, Installed And In Use At The Time Of Quote/bid Any And All Software Necessary To Technically Support The System Shall Be Included Any And All Components Not Manufactured By The Vendor/primary Manufacturer Shall Be Listed As Such With Name/address/contact Information Of The Manufacturer Supplied Devices Must Meet All Currently Applicable Safety Standards, Local And International Where Applicable. Vendor Shall Confirm And Certify In Writing That Parts And Labor Will Be Available For The Quoted System For Not Less Than Five (5) Years After The Warranty Period Vendor Shall Agree To Provide Factory Or Principal Manufacturer Training And/or Certification For At Least One (1) In-house Biomedical Technologist Or Engineer And/or End-user. Vendor May Include Post-warranty Comprehensive Preventive Maintenance Program Proposal For The Next 3-4 Years And Must Also Indicate Cost Estimates For Major Spare Part/s Vendor To Shoulder Any Expenses Related To Delivery, Installation, Commissioning, Permit/s, Training And Other Sundries Necessary For The Complete Installation Of The Equipment Vendor Must Have Available Technical Staff And/or Office/s Within The Region Vendor Must Have An Existing / Active Quality Management System Certification E.g. Iso 13485 And/or Iso 9001 Progress Billing And Payment May Be Availed By The Winning Bidder As Follows, Otherwise, Full Payment Is Due At The Completion Of The Project And Requirements: 15% Upon Delivery At Site; 30% Upon Complete Installation, And 55% Upon Completion Of Project And/or Acceptance Of End-user. Principal’s / Manufacturer’s Products Must Have Been Present In The Local Market For The Past Ten (10) Years Completion Period For Delivery Must Not Exceed 120 Calendar Days And Succeeding Installation Must Not Exceed 120 Calendar Days. Any Deviation From This Limit Requires Prior Approval By The Head Of The Procuring Entity (hope) And Only Applies During Extenuating Circumstances. -.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.- Item No.: 4 Item Description: Ventilator, Mechanical Unit: Lot Qty: 15 Unit Cost: 2,000,000.00 Total Cost: 30,000,000.00 Description: Supply, Delivery, Installation, Testing & Commissioning Of Various Medical Equipment Ventilator, Mechanical Dimensions Monitor:at Least H:45xw:39 X L:17 Centimeters(cm) Ventilator Module:h:33 X W:45 X Depth:25 Cm Compressor: H: 41 X W:45 X Depth:60 Cm Weight Ventilator: At Least 23 Kilograms (kg); Compressor: At Least 25 Kg Electrical Input Mains Voltage: 220-240 Volts Ac Maximum Current: 4.1 Ampere/s Or Less Power Consumption: 943 Va Or Less Iec 601-1 Classification: Protection Class I, Type B, Internally Powered, Drip-proof Equipment, Continuous Operation Patient Circuit Type: Adult / Pediatric / Neonatal Display: Liquid Crystal Display Touch Screen At Least 23 Inches, Colored Pneumatic Gas Sources: Compressed Air 35-100 Psi; Oxygen: 35-100 Psi Pneumatic Specification: Max Limited Pressure: At Least 127.5 Cmh2o; Maximum Working Pressure: At Least 100 Cmh2o; Exhaled Tidal Volume: At Least 0-6000 Ml; Total Minute Volume Range: At Least 0-9.99 L Alarm Volume: 45-85 Dba Connectors: Inspiratory Limb Connector: Iso 22 Mm Conical Male; Expiratory Limb Connector (on Expiratory Filter): Iso 22 Mm Connector Male; Air And Oxygen Inlets: Diss Male, Diss Female And/or Sis Fitting Back Up Power Source (battery): Back Up Time: 2-4 Hours; Dimensions: At Least H:8 X W:24 X Depth:25 Cm; Weight: At Least 6 Kg Mounting: Cart At Least H:99 X W:58 X Depth:60 Cm; Weight: At Least 15 Kg Modes: Assist Control (ac), Synchronous Intermittent Mandatory Ventilation (simv), Spontaneous (spont), Bi-level Software Options: N-cpap, Leak Compensation, Tube Compensation, Bi-level, Volume Ventilation Plus (volume Control Plus Volume Support), Proportional Assist Ventilation Plus (pav+), Respiratory Mechanics, Trending Mandatory Breath Types: Volume Control (vc), Pressure Control (pc), Volume With Volume Ventilation Plus Option Spontaneous Breath Types: Pressure Support (ps), Volume Support (vs), Proportional Assist (pa); Ventilation Type: Invasive, Non-invasive Trigger Type: Pressure Triggering, Flow Triggering Ventilation Settings Ideal Body Weight (ibw): 3.5 To 149 Kg; 0.5 To 149 Kg With Neonatal Mode Tidal Volume: As Low As 2 Milliliters Per Minute (ml/min) (as Low As 300 Grams Per Body Weight); Pressure Support 0 To 70 Cmh2o Rise Time %: 1% To 100% Expiratory Sensitivity: 1% To 80%; 1 To 10 L/min With Pav + Tidal Volume: 25 To 2500 Ml; 5 To 315 Ml With Neonatal Mode; Respiratory Rate: 1.0 To 100 Per Minute; 1 To 150 Per Minute With Neonatal Mode; Peak Inspiratory Flow: 1 To 30 L/min With Neonatal Patient Circuit; 3 To 60 L/min With Pediatric Patient Circuit And 3 To 150 L/min With Adult Patient Circuit; Peep 0 To 45 Cmh2o Flow Pattern: Square Or Descending Ramp Inspiratory Pressure: 5 To 90 Cmh2o Inspiratory Time 0.2 To 8.0 Seconds Oxygen %: 21 To 100% Plateau Time: 0.0 To 2.0 Seconds Alarm Settings Apnea Interval High Circuit Pressure Limit: 7 To 100 Cmh2o; High Exhaled Minute Volume: 0.1 To 99.9 L Or Off High Exhaled Tidal Volume: 50 To 3000 Milliliters (ml) Or Off, 5 To 300 Ml Or Off With Neonatal Mode High Respiratory Rate 10 To 110 Per Minute Or Off High Inspired Mandatory Tidal Volume Low Exhaled Mandatory Tidal Volume 5 To 250 Ml Or Off, 1 To 300 Ml Or Off With Neonatal Mode Alarm Settings Low Exhaled Minute Volume 0.05 To 60 L, 0.01 To 10.0 L Or Off With Neonatal Mode Low Exhaled Spontaneous Tidal Volume 5.0 To 2500 Ml Or Off, 1 To 300 Ml Or Off With Neonatal Mode Low Circuit Pressure Alarm Limit Oxygen Sensor Monitored Data Breath Type Delivered Oxygen % End Expiratory Pressure End Inspiratory Pressure Exhaled Minute Volume Exhaled Tidal Volume I:e Ratio Intrinsic Peep Mean Circuit Pressure Peak Circuit Pressure Plateau Pressure Rapid Shallow Index Spontaneous Inspiratory Time Spontaneous Minute Volume Spontaneous Percent Inspiratory Time Static Compliance Static Resistance Total Peep Total Respiratory Rate Integral Waveforms Function Pressure-time Curve Flow-time Curve Volume-time Curve Pressure-volume Loop Flow Volume-loop All Waveforms Can Be Frozen Adjustable Baseline And Vertical/horizontal Axis Scales Event And Alarm Logs Trending Function At Least 50 Parameters Monitored Over At Least A 72-hour Period Accessories Must Include The Following Accessories For Each Ventilator Unit: Flexible Arm, At Least One Piece Per Unit Oxygen Cell, At Least One Piece Per Unit Flow Sensor, At Least One Piece Per Unit Inspiratory Filter, At Least One Piece Per Unit Active Exhalation Filter, At Least One Piece Per Unit External Nebulizer, At Least One Piece Per Unit Expiratory Bacterial Filter, At Least Two Piece Per Unit Operating Manual In English, At Least One Copy Per Unit Service Manual With Diagram/s, At Least One Copy Per Unit Uninterruptible Power Supply (ups) Capable Of Backing Up Ventilator And Compressor For Each Unit. Inclusions: Ten (10) Sets Adult Ventilator Circuit For Each Unit. Particulars Vendor Shall Warrant That The Product Supplied Shall Equal The Published Specifications. Vendor Shall Provide No Less Than Five (5) Years Warranty On The System/equipment For Spare Parts And Service Upon Acceptance By End User/s. Vendor Agrees To Provide Free Of Charge All Parts And Labour Necessary To Repair The System During The Period Covered By The Warranty And Replacement Of Any Item/s And/or Part/s Found To Be Defective In Material Or Workmanship Under Normal Use. Vendor Must Conduct Quarterly Preventive Maintenance Program Or Frequently As Recommended By Principal / Manufacturer. Vendor Agrees To Add Equipment Down-time (in Number Of Days) To Total Warranty Period. Vendor Must Respond With Technical Support Staff, Either Remotely Or In-person Where Applicable, Within At Least Twenty-four (24) Hours Upon Notification Of End-user; And Must Perform Corrective Maintenance Within A Maximum Of Fourteen (14) Days Upon Notification Of End-user. System/equipment Shall Be Delivered With At Least One (1) Copy Of All Service Manuals And At Least One (1) Copy Of All User Manuals. System/equipment Shall Be Delivered Complete With All Cabling, Connectors, Junction Boxes, Mounting Hardware, And All Other Accessories Necessary For Full Operation Of The System/equipment, Where Applicable. Vendor Must Certify That All Products Quoted Must Be In Current Production And Publicly Available As Of The Date Of This Tender. Unproven Future Products Shall Not Be Accepted. All Desired Features Listed Must Be In Current Production, Installed And In Use At The Time Of Quote/bid Any And All Software Necessary To Technically Support The System Shall Be Included Any And All Components Not Manufactured By The Vendor/primary Manufacturer Shall Be Listed As Such With Name/address/contact Information Of The Manufacturer Supplied Devices Must Meet All Currently Applicable Safety Standards, Local And International Where Applicable. Vendor Shall Confirm And Certify In Writing That Parts And Labor Will Be Available For The Quoted System For Not Less Than Five (5) Years After The Warranty Period Vendor Shall Agree To Provide Factory Or Principal Manufacturer Training And/or Certification For At Least One (1) In-house Biomedical Technologist Or Engineer And/or End User. Vendor May Include Post-warranty Comprehensive Preventive Maintenance Program Proposal For The Next 3-4 Years And Must Also Indicate Cost Estimates For Major Spare Part/s. Vendor To Shoulder Any Expenses Related To Delivery, Installation, Commissioning, Permit/s, Training And Other Sundries Necessary For The Complete Installation Of The Mechanical Ventilator. Vendor Must Have Available Technical Staff And/or Office/s Within The Region. Where Applicable, Vendor Must Issue Dicom Conformance Statement Ensuring Delivered Equipment Is At Least Dicom Enabled And Ensures Interoperability With The Hospital’s Existing It Software, Equipment And Other System/s. E.g. Electronic Medical Record/s And/or Hospital Information System/s. Vendor Must Have An Existing / Active Quality Management System Certification E.g. Iso 13485:2016 And Its Equivalent For Importation, Warehousing, Installation & Servicing Of Active And Non-active Medical Services. Principal’s / Manufacturer’s Product Portfolio Must Have Been Present In The Local Market For The Past Ten (10) Years Progress Billing And Payment May Be Availed By The Winning Bidder As Follows, Otherwise, Full Payment Is Due At The Completion Of The Project And Requirements: 15% Upon Delivery At Site; 30% Upon Complete Installation, And 55% Upon Completion Of Project And/or Acceptance Of End-user. Completion Period For Delivery Must Not Exceed 120 Calendar Days And Succeeding Installation Must Not Exceed 120 Calendar Days. Any Deviation From This Limit Requires Prior Approval By The Head Of The Procuring Entity (hope) And Only Applies During Extenuating Circumstances. -.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-
Contact
Tender Id
157e0d77-5293-35d5-9765-08b7f396b79bTender No
11383308Tender Authority
GOVERNOR CELESTINO GALLARES MULTI SPECIALTY MEDICAL CENTER ViewPurchaser Address
-Website
notices.philgeps.gov.ph