- Home/
- United States/
- DEPT OF THE NAVY USA/
- Overview
DEPT OF THE NAVY USA Tender
DEPT OF THE NAVY USA Tender
Costs
Summary
59--cca,relay, In Repair/modification Of
Description
Contact Information|4|n744.11|ge1|717-605-7296|rachel.e.snyder@navy.mil| item Unique Identification And Valuation (mar 2022)|19|||||||||||||||||||| higher-level Contract Quality Requirement (navicp Review Feb 1991)(feb 1999)|1|iso9001, Please Reference Tdp| inspection Of Supplies--fixed-price (aug 1996)|2||| wide Area Workflow Payment Instructions (dec 2018)|16|combo Invoice And Receiving||tbd|n00104|tbd|tbd|see Schedule|tbd|||tbd|||||| navy Use Of Abilityone Support Contractor - Release Of Offeror Information (3-18))|1|wss| equal Opportunity (sep 2016)|2||| warranty Of Data--basic (mar 2014)|2||| buy American --free Trade Agreements--balance Of Payments Program - Basic(deviation 2020-o0019) (mar 2022))|3|||| alternate A, Annual Representations And Certifications (nov 2020)|13|||||||||||||| buy American-free Trade Agreements-balance Of Payments Program Certificate (deviation 2020-o0019) (jul 2020))|3|||| buy American-balance Of Payments Program Certificate-basic (nov 2014)|1|| annual Representations And Certifications (jan 2022)|13|335314|750|||||||||||| notice Of Priority Rating For National Defense, Emergency Perpardeness, And Enrgy Progam Use (april 2008))|2||x| evaluation Criteria And Basis For Award-|1|| subject Amendment Is Hereby Incorporated To Make The Following Changes: qty 6 Is Hereby Increased By Qty 3 To Qty 9. to Extend The Closing Date To 13 Sep 2024. all Other Terms And Conditions Remain Unchanged. 1. Amendment 0001 Increases The Quantity Of This Order From 5 Units To 6 Units. 2. The Quote Due Date Is Extended From 31 May 2022 To 31 May 2024. 3. All Other Terms And Conditions Remain Unchanged. \ 1. This Solicitation Is For The Repair Of 5 Each Nsn 5945 014713214 In Accordance With Reference Number 100h417g01. Replacement Or New Procurement Will Not Be Considered. The Government Does Not Own The Drawings Or Data Rights To This Nsn. 2. Government-source Inspection And Acceptance (g-s I&a) Is Required. If The G-s I&a Will Occur At A Different Cage From The Admin Award Cage, Please Provide The Repair Facility Cage And/or Packaging Cage With The Quote. ---the Navy Does Not Possess The Technical Data Necessary To Repair This Item. The Repair Of This Item Has Been Determined To Be Sole Source. Only Sources That Are Approved By The In-service Engineering Activity (isea) May Be Considered For The Repair Of This item. If Your Company Is Interested In Becoming An Approved Repair Source, Your Company Must Be Certified As A Depot Overhaul Point (dop). If You Believe Your Organization Possesses The Requisite Technical Data And Capability To Repair This Item, Please complete/return A Source Approval Request (sar)-maritime (available For Download At Https://www.navsup.navy.mil/public/navsup/business_opps_vendor_form/ . Once Your Sar Request Isreceived, A Technical Referral Will Be Submitted To The Naval Sea Systems Command (navsea) Isea For Review And Engineering Determination Of Your Repair Capabilities. Please Be Aware That The Technical Review Is Under The Authority Of Navsea And The Process To Become An Approved Source Can Be Lengthy. Offers Submitted For Remanufactured, Surplus Or New Procurement Acquisitions Will Not Be Considered And Determined Non-responsive. --- Note To Distributors/dealers: if You Are A Distributor, Your Quotation Must Be Accompanied With A Letter From The Actual Manufacturer Indicating That You Are An "authorized" Distributor. if You Are A Dealer, Your Quotation Must Be Accompanied With A Statement Clearly Identifying Your Firm As A Dealer Along With The Oem's Name/cage Code And P/n That You Intend On Providing. 3. Please Provide The Following Information In The Repair Quote: a. Your Cage (used As The Awardee Cage):___________________ B. The Unit Repair Price: $____________________________________ and Whether This Price Is Firm-fixed Price (ffp)_____; Or Not-to-exceed (nte)______ c. Repair Turn-around Me (number Of Days From Receipt Of Asset(s) To Shipment Of Repaired Asset(s):_______days D. Throughput Constraint: _____/month. Refers To The Total Assets To Be Repaired Monthly After Initial Delivery Commences. A Throughput Of 0000/month Reflects No Throughput Constraint. e. The New Procurement Cost Of This Nsn (if Known): $________________________ f. Is This Item (nsn) Obsolete: Yes____ Or No _____ g. The Repair Cage _____________ And Packaging Cage___________ (as Described In#2). Please Note The Following When Generating Your Quote: we Are Requesting That The Quotes Validity Extend For 8 Months From The Submittted Proposal Date. teardown And Evaluation Only Quotes Will Not Be Accepted. induction Expiration Date: 120 Days After The Date Of Subsequent Award. Any Asset Received After This Date In Days Is Not Authorized To Be Repaired Without Bi-lateral Agreement Between The Vendor And Contracting Officer. if Firm-fixed Repair Pricing Is Provided, Beyond Economical Repair (ber) Does Not Exist. With Dcma Concurrence, Beyond Repair (br) Is Possible. If The Unit Isdetermined Br, The Unit Price Will Negotiated Downward From The Awarded Firm-fixed Repair Price. 4.since There Is Only One Business Concern Capable Of Performing Repairs On This Nsn, The Small Business Set-aside Requirement Has Been Dissolved. 5. All Contractual Documents (i.e. Contracts, Purchase Orders, Task Orders, Delivery Orders And Modifications)related To The Instant Procurement Are Considered To Be "issued" By The Government When Copies Are Either Deposited In The Mail, Transmitted By facsimile, Or Sent By Other Electronic Commerce Methods, Suchas Email. The Government's Acceptance Of The Contractor's Proposal Constitutes Bilateral Agreement To "issue" Contractual Documents As Detailed Herein. 6. Please Submit A Repair Quote To Rachel Snyder Via Email: Rachel.e.snyder@navy.mil This Is The Only Submission Method Authorized. 7. Please Direct Questions Regarding This Solicitation To The Person Listed Above (#6). 8. The Resultant Award Of This Solicitation Will Be Issued Bilaterally, Requiring The Contractors Written Acceptance Prior To Execution. \ 1. Scope 1.1 This Contract/purchase Order Contains The Requirements For Repair And The Contract Quality Requirements For The Cca,relay . 2. Applicable Documents 2.1 Applicable Documents - The Document(s) Listed Below Form A Part Of This Contract/purchase Order Including Modifications Or Exclusions. 2.1.1 "document References" Listed Below Must Be Obtained By The Contractor. Ordering Information Is Included As An Attachment To This Contract/purchase Order. document Ref Data=mil-std-129 | | |p |041029|a| |03| document Ref Data=iso9001 | | | |010417|a| | | 3. Requirements 3.1 Cage Code/reference Number Items - The Cca,relay Repaired Under This Contract/purchase Order Shall Meet The Operational And Functional Requirements As Represented By The Cage Code(s) And Reference Number(s) Listed Below. All Repair Work Shall Be performed In Accordance With The Contractors Repair/overhaul Standard Practices, Manuals And Directives Including But Not Limited To Drawings, Technical Orders, Manufacturing Operations, Tooling Instructions, Approved Repair Standards And Any Other Contractor or Government Approved Documents Developed To Provide Technical Repair Procedures. cage___ref. No. ;04804 100h417g01; 3.2 The Contractor Shall Develop And Deliver A Repair Report For Each Item Provided To The Contractor For Repair Under This Contract, Within 10 Days After Completion Of The Repair.(cdrl A001) 3.2.1 For Items Determined To Be Not Repairable; The Item Shall Be Returned To The Government In Its Original Or Comparable Packaging, Along With Documentation That Appropriately Indicates Its Non-repairable Condition. 3.3 Marking - This Item Shall Be Physically Identified In Accordance with ;mil-std-129; . 3.4 Changes In Design, Material Servicing, Or Part Number - Except For A Code 1 Change, Which Shall Be Processed As Provided In The Code Statement Shown Below, No Substitution Of Items Shall Be Made Until The Navicp-mech Contracting Officer Has Notified And approval Has Been Given By Issuance Of A Written Change Order. When Any Change In Design, Material, Servicing Or Part Number Is Made To Replace Or Substitute Any Item To Be Furnished On This Contract/purchase Order, The Contractor Shall Furnish, For The substituting/replacement Item, A Drawing And An Explanation Of The Reason For The Change, Explaining The Reason Therefor. If Finished Detail Drawings Are Not Available, Shop Drawings In The Form Used By The Manufacturer Will Be Acceptable For Government evaluation. When Notifying The Procurement Contracting Officer Of The Reasons For Making Substitutions, The Type Of Change Shall Be Indicated By Code Number In Accordance With One Of The Following Statements: code 1: Part Number Change Only - If The Manufacturer's Part Number Indicated Thereon Has Changed, But The Parts Are Identical In All Respects, Supply The Item And Advise Navicp-mech Immediately Of The New Part Number. code 2: Assembly (or Set Or Kit) Not Furnished - Used Following Detail Parts. code 3: Part Not Furnished Separately - Use Assembly. code 4: Part Redesigned - Old And New Parts Are Completely Interchangeable. code 5: Part Redesigned - New Part Replaces Old. Old Part Cannot Replace New. code 6: Part Redesigned - Parts Not Interchangeable. 3.5 Mercury Free - The Material Supplied Under This Contract/purchase Order Is Intended For Use On Submarines/surface Ships And Therefore Shall Contain No Metallic Mercury And Shall Be Free From Mercury Contamination. Mercury Contamination Of The Material will Be Cause For Rejection. If The Inclusion Of Metallic Mercury Is Required As A Functional Part Of The Material Furnished Under This Contract, The Contractor Shall Obtain Written Approval From The Procurement Contracting Officer Before Proceeding With Manufacture. The contractor's Request Shall Explain In Detail The Requirements For Mercury, Identify Specifically The Parts To Contain Mercury, And Explain The Method Of Protection Against Mercury Escape. Such A Request Will Be Forwarded Directly To The Procurement Contracting officer With A Copy To The Applicable Government Inspector. Upon Approval By The Contracting Officer, The Vendor Will Provide A "warning Plate" Stating That Metallic Mercury Is A Functional Part Of The Item And Will Include Name And Location Of That Part. The Use Of Mercury, Mercury Compounds, Or Mercury-bearing Instruments And/or Equipment In A Manner Which Might Cause Contamination In The Manufacture, Assembly, Or Test Of Material On This Contract Is Prohibited. The Most Probable Causes Of contamination Are Direct-connected Manometers, Mercury Vacuum Pumps, Mercury Seals, Or The Handling Of Mercury In The Immediate Vicinity. Mercury Switches, Mercury In Glass Thermometers, Standard Cells And Other Items Containing Mercury May Be Used If They Are located So As Not To Constitute A Contamination Hazard. If External Contamination By Metallic Mercury Occurs Or Is Suspected, The Following Test May Be Used To Determine Whether Contamination By Metallic Mercury Exists Or Whether Corrective Cleaning Measures Have Been Effective. Enclose The Equipment In A polyethylene Bag Or Close-fitting Airtight Container For Eight Hours At Room Temperature (70 Degrees F Minimum).sample The Trapped Air And If Mercury Vapor Concentration Is 0.01 Mg/cu Meter Or More, The Material Is Mercury Contaminated Insofar As The requirements Of This Contract Are Concerned. These Requirements Shall Be Included In Any Subcontract Or Purchase Order Hereunder And The Contractor Shall Insure Subcontractor Compliance With These Requirements. Technical Questions Pertaining To These Requirements Shall Be Referred To The Procurement Contracting Officer Via The Cognizant Administrative Contracting Officer. For Background, The Following Information Is Provided: Mercury Is Corrosive To Gold, Silver, Nickel, Stainless Steels, Aluminum And Copper Alloys. Stainless Steels, Nickel, And Copper Alloys Are Widely Used In Reactor Plants And Other Submarine/surface Ship Systems. Accidental Trapping Of Mercury In A component Could Cause Serious Damage To Vital Parts. Mercury Is Also Toxic If Inhaled, Ingested, Or Absorbed Through The Skin. It Is Evident That Grave Consequences Could Result From Small Amounts Of Mercury Vapor Present In An Unreplenished Submarine/surface ship Atmosphere. 3.6 Electrostatic Discharge Control - The Contractor Shall Comply With The Electrostatic Discharge Control Requirements Established In Mil-std-1686. 4. Quality Assurance 4.1 Responsibility For Inspection - Unless Otherwise Specified In The Contract/purchase Order, The Contractor Is Responsible For The Performance Of All Inspection Requirements As Specified Herein. Except As Otherwise Specified In The Contract/purchase Order, the Contractor May Use His Own Or Any Other Facilities Suitable For The Performance Of The Inspection Requirements Specified Herein, Unless Disapproved By The Government. The Government Reserves The Right To Perform Any Of The Inspections Set Forth In The specification Where Such Inspections Are Deemed Necessary To Assure Supplies And Services Conform To Prescribed Requirements. 4.2 Inspection/testing Repaired Items - The Contractor Shall Perform All Inspection And Testing Requirements As Specified In The Original Manufacturer's Specifications And Drawings. 4.3 Records - Records Of All Inspection Work By The Contractor Shall Be Kept Complete And Available To The Government During The Performance Of Contract/purchase Order And For A Period Of 365 Calendar Days After Final Delivery Of Supplies. 4.4 Repair Report (cdrl A001) Repair Reports Shall Be Provided Of Each Item To Document Findings, Root Cause And All Actions Taken From Time Of Receipt Through Delivery Back To The Government. Reports Shall Identify The Steps Taken To Perform Inspections Andassess Item Condition; findings Of Said Inspections/assessments; Corrective Actions Taken To Repair; Tests And Qa Inspections Performed; And Any/all Results. Furthermore, Based On The Findings In Executing The Above And/or Ancillary Information Readily Available To The Contractor, the Contractor Shall Include Their Assessment For The Root Cause Of Any Failures Found. If Aroot Cause Cannot Be Definitively Determined Without More Invasive Efforts Or Addition Government Furnished Information, The Contractor Shall Make Best Efforts To List the Most Probable Or Plausible Causes Of The Failure. 5. Packaging 5.1 Preservation, Packaging, Packing And Marking - Preservation, Packaging, Packing And Marking Shall Be In Accordance With The Contract/purchase Order Schedule And As Specified Below. mil-std 2073 Packaging Applies As Found Elsewhere In The Schedule 6. Notes 6.1 Ordering Information For Document References - The Department Of Defense Single Stock Point (dodssp), Website Http://www.dsp.dla.mil/, Provides Product Information For The Department Of Defense Index Of Specifications And Standards (dodiss) (i.e.military/federal Specifications And Standards), Data Item Descriptions (dids), And Other Dodssp Products. a. Availability Of Cancelled Documents - The Dodssp Offers Cancelled Documents That Are Required By Private Industry In Fulfillment Of Contractual Obligations In Paper Format. Documents Can Be Requested By Phoning The Subscription Services Desk. b. Commercial Specifications, Standards, And Descriptions - These Specifications, Standards And Descriptions Are Not Available From Government Sources. They May Be Obtained From The Publishers Of The Applicable Societies. C. Ordnance Standards (os), Weapons Specifications (ws), And Navord Ostd 600 Pages - These Type Publications May Be Obtained By Submitting A Request To: Commander, Indian Head Division, Naval Surface Warfare Center Code 8410p, 101 Strauss Avenue Indian Head, Md 20640-5035 d. On Post-award Actions, Requests For "official Use Only" And "noforn" (not Releasable To Foreign Nationals) Documents Must Identify The Government Contract Number, And Must Be Submitted Via The Cognizant Defense Contract Management Command (dcmc) For certification Of Need For The Document. On Pre-award Actions Such Requests Must Be Submitted To The Pco For Certification Of Need For The Document. e. Noforn Military Specifications And Standards (including Amendments, Change Notices And Supplements, But Not Interim Changes) To Be Ordered From: Contracting Officer Navicp-mech Code 87321 5450 Carlisle Pike P.o. Box 2020 Mechanicsburg, Pa. 17055-0788 f. Nuclear Reactor Publications Assigned Navsea Documents And Identification Numbers (i.e. Navsea Welding Standard, Navsea 250-1500-1) Are To Be Ordered From: Commanding Officer Navicp-mech Code 009 5450 Carlisle Pike P.o. Box 2020 Mechanicsburg, Pa. 17055-0788 g. Technical Manuals Assigned Navsea Identification Numbers (i.e. Navsea Welding And Brazing Procedure, Navsea S9074-aq-gib-010/248) Are To Be Ordered From: Naval Inventory Control Point Code 1 Support Branch 700 Robbins Avenue Phildelphia, Pa. 19111-5094 h. Interim Changes And Classified Specifications Shall Be Obtained By Submitting A Request On Dd Form 1425 To Navicp-mech. date Of First Submission=asreq repair Reports Shall Be Provided Of Each Item To Document Findings, Root Cause And All Actions Taken From Time Of Receipt Through Delivery Back To The Government. See 4.2 For More Details. blk 9: Distribution Statement D: Distribution Authorized To U.s. Government Agencies Only For Administrative And Operational Use. Other Requests For This Document Shall Be Referred To Commander, Naval Surface Warfare Center, Philadelphia Division, 5001 South broad Street, Building 4, Philadelphia, Pa 19112. blocks 10, 11, 12, 13 reports Shall Be Submitted Within 10 Business Days Of The Completion Of The Repair block 14 submit Via Electronic Mail In A Digital Format That Can Be Read By Microsoft Office 2010 Applications (or Earlier) Or Adobe Pdf Applications To The Distribution Addresses Identified In Attachment 1 To Exhibit A. technical Point Of Contacts Are: phil Criswell Philip.w.criswell.civ@us.navy.mil (215) 897-1194 steven Loher Steven.m.loher.civ@us.navy.mil (215) 897-1399
Contact
Tender Id
N0010422QND92Bid Award Id
ViewTender No
N0010422QND92Tender Authority
DEPT OF THE NAVY USA ViewPurchaser Address
-Website
beta.sam.gov