Cotabato Regional And Medical Center Tender
Cotabato Regional And Medical Center Tender
Costs
Summary
Supply & Delivery Of Medical Equipment , Hospital / Medical Equipment ,cotabato Regional And Medical Center
Description
Description 500 Roll Ultrasound Sono/thermal Paper For Sony Upp- 110 Series , Abc 900.00/roll Ultrasound Sono/thermal Paper For Sony Upp- 110 Series Ultrasound Sono/thermal Paper For Sony Upp- 110 Series 3 Unit Doppler/eda Sonotrax Vascular Doppler Doppler/eda , Abc 30,000.00/unit Sonotrax Vascular Doppler Doppler/eda Sonotrax Vascular Doppler Technical Specification: Technical Specification: Technical Specification: Ergonomic Design, Compact And Light Ergonomic Design, Compact And Light Ergonomic Design, Compact And Light Large Backlight Lcd Display Large Backlight Lcd Display Large Backlight Lcd Display Accurate Fhr Detection With Clear Sound Accurate Fhr Detection With Clear Sound Accurate Fhr Detection With Clear Sound High Sensivity Interchangeable Probe High Sensivity Interchangeable Probe High Sensivity Interchangeable Probe Supports 2mhz, 3mhz, 4mhz, 5mhz, 8mhz Waterproof Probes Supports 2mhz, 3mhz, 4mhz, 5mhz, 8mhz Waterproof Probes Supports 2mhz, 3mhz, 4mhz, 5mhz, 8mhz Waterproof Probes Real Time Automatic And Manual Hfr Real Time Automatic And Manual Hfr Real Time Automatic And Manual Hfr Long Time Continuous Use About 8 Hours Long Time Continuous Use About 8 Hours Long Time Continuous Use About 8 Hours Charging Time: Up To 4 Hours Charging Time: Up To 4 Hours Charging Time: Up To 4 Hours Automatic Power-off Automatic Power-off Automatic Power-off Probe Cable Lenght: At Least 2.5m Probe Cable Lenght: At Least 2.5m Probe Cable Lenght: At Least 2.5m Fhr Measurement Range: Up To 210bpm Fhr Measurement Range: Up To 210bpm Fhr Measurement Range: Up To 210bpm Fhr Frquency: Up To 8mhz Fhr Frquency: Up To 8mhz Fhr Frquency: Up To 8mhz Audio Sampling Frquency: Up To 4khz Audio Sampling Frquency: Up To 4khz Audio Sampling Frquency: Up To 4khz Recording: At Least 240 Seconds Recording: At Least 240 Seconds Recording: At Least 240 Seconds Inclusions: Inclusions: Inclusions: With Complete Accessories (probe, Charger, Etc), With Complete Accessories (probe, Charger, Etc), With Complete Accessories (probe, Charger, Etc), With Calibartion Cetrifcate With Calibartion Cetrifcate With Calibartion Cetrifcate General Conditions: General Conditions: General Conditions: The Product Must Be International Standard Compliant The Product Must Be International Standard Compliant The Product Must Be International Standard Compliant Two Years Warranty On Parts And Services Two Years Warranty On Parts And Services Two Years Warranty On Parts And Services To Submit Operation & Service Manual In English Language To Submit Operation & Service Manual In English Language To Submit Operation & Service Manual In English Language To Include Delivery, Installation And Testing To Include Delivery, Installation And Testing To Include Delivery, Installation And Testing The Bidder Must Be Exclusive Distributor, To Submit A Certificate The Bidder Must Be Exclusive Distributor, To Submit A Certificate The Bidder Must Be Exclusive Distributor, To Submit A Certificate Of Exclusive Distributorship Of Exclusive Distributorship Of Exclusive Distributorship To Submit A Certificate Of Parts Availability For At Least 10 Years To Submit A Certificate Of Parts Availability For At Least 10 Years To Submit A Certificate Of Parts Availability For At Least 10 Years The Bidder Must Have A Service Engineers/technician Based In Mindanao The Bidder Must Have A Service Engineers/technician Based In Mindanao The Bidder Must Have A Service Engineers/technician Based In Mindanao 1 Unit Vital Signs Monitor With Stand (welch Allyn Connex , Abc 100,000.00/unit Vital Signs Monitor With Stand (welch Allyn Connex Vital Signs Monitor With Stand (welch Allyn Connex 6500 Vital Signs Monitor) 6500 Vital Signs Monitor) 6500 Vital Signs Monitor) Technical Specification: Technical Specification: Technical Specification: Electrical Rating: 240 V Ac, 60 Hz Electrical Rating: 240 V Ac, 60 Hz Electrical Rating: 240 V Ac, 60 Hz Duty Cycle: Continuous Operation Duty Cycle: Continuous Operation Duty Cycle: Continuous Operation Type Of Protection Against Electrical Shock: Class I Equipment Type Of Protection Against Electrical Shock: Class I Equipment Type Of Protection Against Electrical Shock: Class I Equipment (protectively Earthed) With Double Insulation, Type Bf (protectively Earthed) With Double Insulation, Type Bf (protectively Earthed) With Double Insulation, Type Bf Battery Specification Battery Specification Battery Specification Operating Time Per Charge For Continuous Monitoring: Operating Time Per Charge For Continuous Monitoring: Operating Time Per Charge For Continuous Monitoring: 2 Hours Or Higher 2 Hours Or Higher 2 Hours Or Higher *nibp Specification *nibp Specification *nibp Specification Units Of Measure: Systolic, Diastolic, Map: Mmhg, Kpa; Units Of Measure: Systolic, Diastolic, Map: Mmhg, Kpa; Units Of Measure: Systolic, Diastolic, Map: Mmhg, Kpa; User-selectable Pulse Rate: Beats Per Minute User-selectable Pulse Rate: Beats Per Minute User-selectable Pulse Rate: Beats Per Minute Systolic Range: Adult: Up To 260 Mmhg Or Higher Systolic Range: Adult: Up To 260 Mmhg Or Higher Systolic Range: Adult: Up To 260 Mmhg Or Higher Pediatric: Up To 260 Mmhg Or Higher, Neonate: Up To 120 Mmhg Pediatric: Up To 260 Mmhg Or Higher, Neonate: Up To 120 Mmhg Pediatric: Up To 260 Mmhg Or Higher, Neonate: Up To 120 Mmhg Diastolic Range: Adult: Up To 220 Mmhg Or Higher Diastolic Range: Adult: Up To 220 Mmhg Or Higher Diastolic Range: Adult: Up To 220 Mmhg Or Higher Pediatric: Up To 220 Mmhg Or Higher, Neonate: Up To 110 Mmhg Pediatric: Up To 220 Mmhg Or Higher, Neonate: Up To 110 Mmhg Pediatric: Up To 220 Mmhg Or Higher, Neonate: Up To 110 Mmhg Cuff Inflation Target: Adult: Up To 1600 Mmhg, Pediatric: Cuff Inflation Target: Adult: Up To 1600 Mmhg, Pediatric: Cuff Inflation Target: Adult: Up To 1600 Mmhg, Pediatric: Up To 120 Mmhg, Neonate: 90 Mmhg Or Higher Up To 120 Mmhg, Neonate: 90 Mmhg Or Higher Up To 120 Mmhg, Neonate: 90 Mmhg Or Higher Maximum Target Pressure: Adult: 280 Mmhg Or Higher Maximum Target Pressure: Adult: 280 Mmhg Or Higher Maximum Target Pressure: Adult: 280 Mmhg Or Higher Pediatric: 280 Mmhg Or Higher, Neonate: 130 Mmhg Or Higher Pediatric: 280 Mmhg Or Higher, Neonate: 130 Mmhg Or Higher Pediatric: 280 Mmhg Or Higher, Neonate: 130 Mmhg Or Higher Blood Pressure Determination Time: 150 Seconds Or Lower Blood Pressure Determination Time: 150 Seconds Or Lower Blood Pressure Determination Time: 150 Seconds Or Lower Mean Arterial Pressure (map) Range: Adult Up To 230 Mmhg Mean Arterial Pressure (map) Range: Adult Up To 230 Mmhg Mean Arterial Pressure (map) Range: Adult Up To 230 Mmhg Pediatric: Up To 230, Neonate: Up To 110 Mmhg Pediatric: Up To 230, Neonate: Up To 110 Mmhg Pediatric: Up To 230, Neonate: Up To 110 Mmhg Pulse Rate Range: Adult: Up To 200 Beats Per Minute Pulse Rate Range: Adult: Up To 200 Beats Per Minute Pulse Rate Range: Adult: Up To 200 Beats Per Minute Pediatric: Up To 200 Beats Per Minute, Neonate: Up To 220 Beats Per Minute Pediatric: Up To 200 Beats Per Minute, Neonate: Up To 220 Beats Per Minute Pediatric: Up To 200 Beats Per Minute, Neonate: Up To 220 Beats Per Minute Pulse Rate Accuracy: ±3 Beats Per Minute Or Better Pulse Rate Accuracy: ±3 Beats Per Minute Or Better Pulse Rate Accuracy: ±3 Beats Per Minute Or Better *temperature Module Specifications *temperature Module Specifications *temperature Module Specifications Units Of Measure: °f, °c; User-selectable Units Of Measure: °f, °c; User-selectable Units Of Measure: °f, °c; User-selectable Temperature Range: Up To 43°c Temperature Range: Up To 43°c Temperature Range: Up To 43°c Calibration Accuracy; ±0.2 Or Better Calibration Accuracy; ±0.2 Or Better Calibration Accuracy; ±0.2 Or Better *spo2 *spo2 *spo2 Unit Of Measure: % Unit Of Measure: % Unit Of Measure: % Measurement Range: Up To 100% Measurement Range: Up To 100% Measurement Range: Up To 100% Saturation Accuracy: ±3 Or Better Saturation Accuracy: ±3 Or Better Saturation Accuracy: ±3 Or Better *pulse Rate *pulse Rate *pulse Rate Unit Of Measure: Beats Per Minute Unit Of Measure: Beats Per Minute Unit Of Measure: Beats Per Minute Measurement Range: Up To 240 Beats Per Minute Measurement Range: Up To 240 Beats Per Minute Measurement Range: Up To 240 Beats Per Minute Accuracy: ±5 Beats Per Minute Or Better Accuracy: ±5 Beats Per Minute Or Better Accuracy: ±5 Beats Per Minute Or Better Operating Temperature: Up To 40°c Operating Temperature: Up To 40°c Operating Temperature: Up To 40°c Storage Temperature; Up To 50°c Storage Temperature; Up To 50°c Storage Temperature; Up To 50°c Operating Humidity: Up To 95% Noncondensing Operating Humidity: Up To 95% Noncondensing Operating Humidity: Up To 95% Noncondensing *inclusions *inclusions *inclusions With Complete Accessories (spo2 Sensor Probe: Adult, With Complete Accessories (spo2 Sensor Probe: Adult, With Complete Accessories (spo2 Sensor Probe: Adult, Pedia, And Neonate And Bp Cuff For: Adult, Pedia And Neonate) Pedia, And Neonate And Bp Cuff For: Adult, Pedia And Neonate) Pedia, And Neonate And Bp Cuff For: Adult, Pedia And Neonate) Stand For Portable Monitor Stand For Portable Monitor Stand For Portable Monitor With Calibartion Cetrifcate, User's And Service Manuals With Calibartion Cetrifcate, User's And Service Manuals With Calibartion Cetrifcate, User's And Service Manuals General Conditions: General Conditions: General Conditions: The Product Must Be International Standard Compliant The Product Must Be International Standard Compliant The Product Must Be International Standard Compliant Two Years Warranty On Parts And Services Two Years Warranty On Parts And Services Two Years Warranty On Parts And Services To Submit Operation & Service Manual In English Language To Submit Operation & Service Manual In English Language To Submit Operation & Service Manual In English Language The Bidder Must Be Exclusive Distributor, To Submit A Certificate The Bidder Must Be Exclusive Distributor, To Submit A Certificate The Bidder Must Be Exclusive Distributor, To Submit A Certificate Of Exclusive Distributorship Of Exclusive Distributorship Of Exclusive Distributorship To Submit A Certificate Of Parts Availability For At Least 10 Years To Submit A Certificate Of Parts Availability For At Least 10 Years To Submit A Certificate Of Parts Availability For At Least 10 Years The Bidder Must Have A Service Engineers/technician Based In Mindanao The Bidder Must Have A Service Engineers/technician Based In Mindanao The Bidder Must Have A Service Engineers/technician Based In Mindanao 20 Bottle Lugol's Iodine 250ml/bot Lugol's Iodine 250ml/bot , Abc 1,200.00/bot Lugol's Iodine 250ml/bot 10 Gallon Acetic Acid (red Cane Vinegar) Acetic Acid , Abc 540.00/gal (red Cane Vinegar) 1 Gallon (del Monte) Acetic Acid (red Cane Vinegar) 1 Gallon (del Monte) Rfq#05-0629r
Contact
Tender Id
49320add-d68b-3673-a261-5f8f1a5948e4Tender No
10861049Tender Authority
Cotabato Regional And Medical Center ViewPurchaser Address
-Website
notices.ps-philgeps.gov.ph