Adela Serra Ty Memorial Medical Center Tender
Adela Serra Ty Memorial Medical Center Tender
Costs
Summary
Procurement Of Medical Equipment Rfq No. 011 , Medical And Dental Equipment ,adela Serra Ty Memorial Medical Center
Description
Description 1 Dermatoscope Machine 2 Unit 150,000.00 300, 000.00 Purpose: Used For Examining Skin Lesions And Structures In Detail, Aiding In The Early Detection Of Skin Camcers (like Melanoma) And Other Dermatological Conditions. It Provides High-quality Imaging With Polarized And Non-polarized Light, Enhancing Visualization Of Vascular Patterns, Pigmentation And Subsurface Features. It’s Valuable For Both Contact And Non-contact Dermoscopy, Making It A Vital Tool For Dermatologists And Skincare Professionals. Features And Benefits 10x Magnication With 30mm Viewing Area. Polirized And Non-polirized Modes With High-powered Leds. Long-lasting Battery Life Includes A Leather Pouch, Silicone Sleeve, And Usb Cable Camera Compatibility Having The Ability To Take A Photo Of A Special Case (prior To Excision), With A Camera, Smartphone Or Ipad, Is Powerful. Carbon Cannot Be Attached To Those Devices. Lens Size Three Lens Sizes: 15, 25 Or 30 Mm. Larger Lenses Provide A Greater Field Of View And Distance From The Patient. Technical Specification Polarization Yes Infection Control Yes Spectrum Control Yes Optics Yes Battery Rechargeable Camera-compatible Yes Phone & Ipad-compatible Yes 10 Mm Markings Yes Ø30 Mm 10x Yes Magnification Ø30 Mm 10x Accessories Usb Cable Leather Pouch Silicone Sleeve Eyepiece Icecap Samples Training, Installation And Utilisation Pre-installation Requirements Requirements For Commissioning *** Supplier To Perform Installation, Safety And Operation Checks Before Handover *** Local Clinical Staff To Affirm Completion Of Installation Training End Users & Biomedical/engineer On-site Training And Orientation Upon Installation. On-site Training And Orientation For Machine Handling And Operation. *** Training Of Users In Operation And Basic Maintenance And Calibration Shall Be Provided *** Supplier To Issue Certificate Of Training *** Advanced Maintenance Tasks Required Shall Be Documented User Care*** Unit Layout To Enable Easy Cleaning And Sterilization Of All Surfaces. Warranty And Maintenance Warranty 3 Years Warranty Should Be Provided By The Supplier Parts = At Least 5 Years Maintenance And Service = At Least 2 Years Spare Parts Availability Post-warranty 10 Years Software / Hardware Upgrade Availability Routine Software Updates Should Be Provided Documentation Documentation Requirements *** User, Technical And Maintenance Manuals To Be Supplied In English Language (3 Copies Each) *** Supplier To Describe Any Materials Contained In The Device That Are Classified As Hazardous Under Local Regulations. *** List To Be Provided Of Important Spares And Accessories, With Their Part Numbers And Cost. *** List To Be Provided Of Equipment And Procedures Required For Local Calibration And Routine Maintenance *** Certificate Of Calibration And Inspection To Be Provided. *** List To Be Provided Of Important Spares And Accessories, With Their Part Numbers And Cost *** Contact Details Of Manufacturer, Supplier And Local Service Agent To Be Provided Decommissioning Estimated Life Span: 10 Years Life Span Safety And Standards Risk Classification Class B (ghtf Rule 10); Class Ii; Class Ii International Standards Iso 13485:2003 Medical Devices -- Quality Management Systems -- Requirements For Regulatory Purposes (australia, Canada And Eu) 2 Auto-clave (steam Sterilizer) 1 Unit 70,000.00 70,000.00 Purpose : Usteam Sterilizers — Also Known As Autoclaves — Are An Essential Piece Of Equipment In Any Laboratory, Research, Or Healthcare Setting, Ensuring Sterility For Important Equipment And Instruments. Autoclaves Are Available In A Wide Array Of Designs, Each Tailored For Specific Applications, Ranging From Small-scale Laboratory Sterilization To Large-volume Industrial Processes. Features And Benefits Automatic Sterilization Controlled By Computer. Temperature Is Max Up To 134 ºc, Suitable For 4-6 Minutes Rapidly Sterilizing. Safety Protection For Water Lacking. Over-temperature, Over-pressure Automatic Protection. Automatically Cuts Off The Power And Then Alarm After Sterilized. Fully Stainless Steel Structure Technical Specification Chamber Volume 24l(φ270×410) Mm / 6.3gallon Working Pressure 0.22mpa Working Temperature 134ºc (273ºf) Temperature Adjust Range 105-134ºc (221-273ºf) Timer Range 0~60min Heat Average ≤±1ºc Power 1.5kw / Ac110v.60hz Sterilizing Plate 340*200*30mm / 13.4*7.9*1.2'', 3 Pieces Overall Dimension 560*350*500mm / 22.0*13.8*19.7'' Packing Dimension 620*410*570mm / 24.4*16.1*22.4'' G.w 20kg / 44lb N.w 18kg / 39lb Accessories 1 Unit 2kva Avr Training, Installation And Utilisation Pre-installation Requirements Requirements For Commissioning *** Supplier To Perform Installation, Safety And Operation Checks Before Handover *** Local Clinical Staff To Affirm Completion Of Installation Training End Users & Biomedical/engineer On-site Training And Orientation Upon Installation. On-site Training And Orientation For Machine Handling And Operation. *** Training Of Users In Operation And Basic Maintenance And Calibration Shall Be Provided *** Supplier To Issue Certificate Of Training *** Advanced Maintenance Tasks Required Shall Be Documented User Care*** Unit Layout To Enable Easy Cleaning And Sterilization Of All Surfaces. Warranty And Maintenance Warranty 3 Years Warranty Should Be Provided By The Supplier Parts = At Least 5 Years Maintenance And Service = At Least 2 Years Spare Parts Availability Post-warranty 10 Years Software / Hardware Upgrade Availability Routine Software Updates Should Be Provided Documentation Documentation Requirements *** User, Technical And Maintenance Manuals To Be Supplied In English Language (3 Copies Each) *** Supplier To Describe Any Materials Contained In The Device That Are Classified As Hazardous Under Local Regulations. *** List To Be Provided Of Important Spares And Accessories, With Their Part Numbers And Cost. *** List To Be Provided Of Equipment And Procedures Required For Local Calibration And Routine Maintenance *** Certificate Of Calibration And Inspection To Be Provided. *** List To Be Provided Of Important Spares And Accessories, With Their Part Numbers And Cost *** Contact Details Of Manufacturer, Supplier And Local Service Agent To Be Provided 3 Cryogenic Handheld Cryosurgery Device (liquid Nitrogen Sprayer System) For Destruction Of Benign Skin Lesions 1 Set 110,000.00 110,000.00 Purpose: Used To Treat Benign Skin Lesions Such As Warts, Skin Tags, And Certain Keratoses. It Applies Extreme Cold To Targeted Areas, Causing Controlled Destruction Of Abnormal Tissue. Features And Benefits The Minimally Invasive Procedure That Uses An Extremely Cold Liquid Or Instrument To Freeze And Destroy Abnormal Tissue That Requires Elimination. It Requires About 1/3 Time Required By Co2 Snow Or N20 To Achieve The Appropriate Degree Of Freezing Because Of The Relative Temperatures(-196°c Compared With -79°c) It Can Be Applied Directly By Spraying The Gun. No Form Of Anaesthesia Is Required For Freezing`; It Can Be Carried Out Single-handed And With No Scarring Results. It Starts Freezing Instantly Because Liquid Nitrogen Is Released Directly On The Internal Metal Probe Wall Which Contacts The Lesion. Portable And Can Be Used In Any Consulting Room. Complete Haemostasis And High Patient Acceptance. A Good Number Of Lesions Can Be Treated At A Time. Carcinoma And Skin Tumours Can Be Treated. Easy To Operate And No Sterilization Is Required To The Tool Or Tips. Technical Specification Durable Stainless Steel And Brass. Capacity: 16 Oz Fingertips Trigger Control, Safely Autovent For Gradual Pressure Release, And A Streamlined Relief Valve For Consistent Freezing. Training, Installation And Utilisation Pre-installation Requirements Requirements For Commissioning *** Supplier To Perform Installation, Safety And Operation Checks Before Handover *** Local Clinical Staff To Affirm Completion Of Installation Training End Users & Biomedical/engineer On-site Training And Orientation Upon Installation. On-site Training And Orientation For Machine Handling And Operation. *** Training Of Users In Operation And Basic Maintenance And Calibration Shall Be Provided *** Supplier To Issue Certificate Of Training *** Advanced Maintenance Tasks Required Shall Be Documented User Care*** Unit Layout To Enable Easy Cleaning And Sterilization Of All Surfaces. Warranty And Maintenance Warranty 2 Years Warranty Should Be Provided By The Supplier Spare Parts Availability Post-warranty 10 Years Documentation Documentation Requirements *** User, Technical And Maintenance Manuals To Be Supplied In English Language (3 Copies Each) *** Supplier To Describe Any Materials Contained In The Device That Are Classified As Hazardous Under Local Regulations. *** List To Be Provided Of Important Spares And Accessories, With Their Part Numbers And Cost. *** List To Be Provided Of Equipment And Procedures Required For Local Calibration And Routine Maintenance *** Certificate Of Calibration And Inspection To Be Provided. *** List To Be Provided Of Important Spares And Accessories, With Their Part Numbers And Cost *** Contact Details Of Manufacturer, Supplier And Local Service Agent To Be Provided 4 Portable Electrosurgical Unit With Trolley 1 Unit 200,000.00 200,000.00 Purpose: A Multi-function Electrosurgical Generator With Both Monopolar And Bipolar Modes, Self-diagnostics, And Recall Of Stored Power Settings High Output Terminal For Heavy Desiccation And Fulguration Procedures Requiring High Intensity. Low Output Terminal For Light Desiccation And Fulguration Procedures Requiring Low Intensity And Increased Precision. Features And Benefits High Output Terminal For Heavy Desiccation And Fulguration Procedures Requiring High Intensity. Low Output Terminal For Light Desiccation And Fulguration Procedures Requiring Low Intensity And Increased Precision. Dual Microprocessors: One Microprocessor Controls The Output And Functionality Of The System While The Second Monitors The System And Terminates Activation If A Safety Hazard Is Detected. This Results In Regulated Delivery Of Current While Simultaneously Ensuring Safe Operation. Technical Specification Depth: 4 Inches (102mm) Width: 8.75 Inches (222mm) Height: 7.5 Inches (190mm) Weight: 6 Pounds (2.7kg) Output Power: Low 0-20 Watts (1/10 Watt Increments Up To 10 Watts) High: 0-35 Watts Bipolar: 0-35 Watts Bipolar Forceps Bipolar Forceps Are Designed To Grasp, Manipulate, And Coagulate Selected Tissue. The Electric Current Alternates Between The Two Tips, Reducing The Length Of The Current’s Path And Producing A Precise, Controlled Therapeutic Effect. Foot Control Pencil Autoclavable Pencils Autoclavable, Reusable Hand Control Pencil Reusable 7-900-5 Steam Autoclavable Hand Control Pencil With Power Adjustment Buttons Directly On The Pencil. Hand Control Pencil Autoclavable, Reusable Foot Control Pencil Consumables Pencil Sheaths – Non-sterile 100/box Pencil Sheaths – Sterile 25/box Accessories Sharp Tip Pencil Sheath Fine Needle Electrode Ball Electrode Training, Installation And Utilisation Pre-installation Requirements Requirements For Commissioning *** Supplier To Perform Installation, Safety And Operation Checks Before Handover *** Local Clinical Staff To Affirm Completion Of Installation Training End Users & Biomedical/engineer On-site Training And Orientation Upon Installation. On-site Training And Orientation For Machine Handling And Operation. *** Training Of Users In Operation And Basic Maintenance And Calibration Shall Be Provided *** Supplier To Issue Certificate Of Training *** Advanced Maintenance Tasks Required Shall Be Documented User Care*** Unit Layout To Enable Easy Cleaning And Sterilization Of All Surfaces. Warranty And Maintenance Warranty 2 Years Warranty Should Be Provided By The Supplier Spare Parts Availability Post-warranty 10 Years Documentation Documentation Requirements *** User, Technical And Maintenance Manuals To Be Supplied In English Language (3 Copies Each) *** Supplier To Describe Any Materials Contained In The Device That Are Classified As Hazardous Under Local Regulations. *** List To Be Provided Of Important Spares And Accessories, With Their Part Numbers And Cost. *** List To Be Provided Of Equipment And Procedures Required For Local Calibration And Routine Maintenance *** Certificate Of Calibration And Inspection To Be Provided. *** List To Be Provided Of Important Spares And Accessories, With Their Part Numbers And Cost *** Contact Details Of Manufacturer, Supplier And Local Service Agent To Be Provided 5 Medical Surgical Smoke Evacuator Evacuation System For Laser And Electrocautery 1 Unit 200,000.00 200,000.00 Purpose: A Medical Surgical Smoke Evacuator Is A Device That Captures And Filters Smoke Generated During Laser And Electrocautery Procedures. These Devices Are Designed To Protect Patients And Surgical Staff From The Harmful Particles And Toxins In The Smoke: Features And Benefits Automated Alert System When Ulpa Filter Is Not Capturing Plume At 100% And Needs To Be Changed. Wide Range Of Accessories To Configure Based On Procedural Needs And Personal Preferences Can Be Placed On A Mobile Cart Or Accessory Shelf On A Surgical Boom. Laser Sensor Utilizes A Convenient Foot Pedal To Activate The Smoke Evacuator. Rf Sensor Is The First Automatic Sensor System For Surgical Smoke Detection And Evacuation. The Rf Sensor Is Capable Of Detecting Any Cutting Device And Simultaneously Activating The Smoke Evacuator. Technical Specification Power Requirements: 100-240 Vac, Single Phase, And 4.0 A, 47-63 Hz Flow Rate: Open Range: At Least 90 Lpm Lap Range: At Least 18 Lpm Display Indicators: Visual, Visual & Audio, Led Meter, Led Display Lcd Display: With Lcd Display Working Noise: 55db Rotating Speed: 2750/min Output Volume: 3.5-4.2cbm3/hr Power Supply: 220/110v,50/60hz Working Mode: Operate Continuously Consumables Smoke Evacuator Filters Hydrophobic Ulpa Filter W/ Fluid Trap Large Charcoal Filter Accessories Esu Pencils With Integrated Smoke Evacuation Smoke Evacuator Tubing Training, Installation And Utilisation Pre-installation Requirements Requirements For Commissioning *** Supplier To Perform Installation, Safety And Operation Checks Before Handover *** Local Clinical Staff To Affirm Completion Of Installation Training End Users & Biomedical/engineer On-site Training And Orientation Upon Installation. On-site Training And Orientation For Machine Handling And Operation. *** Training Of Users In Operation And Basic Maintenance And Calibration Shall Be Provided *** Supplier To Issue Certificate Of Training *** Advanced Maintenance Tasks Required Shall Be Documented User Care*** Unit Layout To Enable Easy Cleaning And Sterilization Of All Surfaces. Warranty And Maintenance Warranty 2 Years Warranty Should Be Provided By The Supplier Spare Parts Availability Post-warranty 10 Years Documentation Documentation Requirements *** User, Technical And Maintenance Manuals To Be Supplied In English Language (3 Copies Each) *** Supplier To Describe Any Materials Contained In The Device That Are Classified As Hazardous Under Local Regulations. *** List To Be Provided Of Important Spares And Accessories, With Their Part Numbers And Cost. *** List To Be Provided Of Equipment And Procedures Required For Local Calibration And Routine Maintenance *** Certificate Of Calibration And Inspection To Be Provided. *** List To Be Provided Of Important Spares And Accessories, With Their Part Numbers And Cost *** Contact Details Of Manufacturer, Supplier And Local Service Agent To Be Provided Total Amount 880,000.00
Contact
Tender Id
ff35be39-5384-37d4-9313-50078fce7408Tender No
11670710Tender Authority
Adela Serra Ty Memorial Medical Center ViewPurchaser Address
-Website
notices.ps-philgeps.gov.ph