Public Works Department Tender

... More
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Public Works Department - PWD Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date1 Mar 2025
Closing DateCancelled
Tender Amount₹ 6,53,12,489 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Routine and Repair Maintenance Work i) EI Works. Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. A) Group A

20

1287

25740

... More
B) Group C

60

1909

114540

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. A) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire

200

338

67600

... More
B) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire

150

443

66450

... More
C) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire

60

609

36540

... More
D) 4 X 4 sq. mm + 2 X 4 sq. mm earth wire

40

700

28000

... More
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. A) Group A

60

594

35640

... More
Group C

200

925

185000

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.

40

606

24240

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a) 8 way, Double door

4

2662

10648

... More
12 way, Double door

6

2395

14370

... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator) a) 4 way (4 + 12), Double door

4

4233

16932

... More
b) 8 way (4 + 24), Double door

2

6173

12346

... More
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) a) 12 way (4 + 36), Double door

2

13277

26554

... More
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

12

1677

20124

... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 63 amps

8

2816

22528

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required a) 63 mm dia (OD-63 mm & ID-51 mm nominal

50

256

12800

... More
b) 90 mm dia (OD-90 mm & ID-76 mm nominal)

50

300

15000

... More
c) 120 mm dia (OD-120 mm & ID-103 mm nominal)

50

381

19050

... More
d) 160 mm dia (OD-160 mm & ID-135 mm nominal)

50

498

24900

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required. A) Upto 35 sq. mm

100

38

3800

... More
B) Above 35 sq. mm and upto 95 sq. mm

50

59

2950

... More
C) Above 95 sq. mm and upto 185 sq. mm

30

80

2400

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing masonry open duct as required. A) Upto 35 sq. mm

50

29

1450

... More
B) Above 35 sq. mm and upto 95 sq. mm

50

47

2350

... More
C) Above 95 sq. mm and upto 185 sq. mm

30

65

1950

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required. A) Upto 35 sq. mm (clamped with 1mm thick saddle)

100

57

5700

... More
B) Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

50

134

6700

... More
C) Above 95 sq. mm and upto 185 sq. mm (clamped with 25/ 40x3mm MS flat clamp)

50

158

7900

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. A) 150 mm width X 50 mm depth X 1.6 mm thickness

100

741

74100

... More
B) 300 mm width X 50 mm depth X 1.6 mm thickness

150

996

149400

... More
Supplying and Replacement of defective Tube light fitting with energy efficient LED battens 18-22 Watt Watt Surface mounted fitting with extruded aluminium housing with output not less than 2000 lumen colour temperature not less than 5700 K suitable for operation on 230 Volt 50 Hz AC Supply directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing i/c buyback of old dismantled material etc. as required.

200

750

150000

... More
Supply and replacement of defective Tube light fitting with energy efficient LED battens 36 Watt Surface mounted fitting with extruded aluminium housing having output not less than 3500 lumen colour temperature not less than 5700 K suitable for operation on 230 Volt 50 Hz AC Supply directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required i/c buyback of old dismantled material etc. as required.

100

2257

225700

... More
Supplying and replacement of 110-120Watt LED Flood light, having die cast housing , toughened glass and system out put of minimum 12000 lumens, having IP66 protection for complete housing. LED chip should have efficacy of 130lumens/watt, CCT of 5700k, CRI :70 and junction temperature of 135 degrees and having a life of 50000 hours with L70 Criteria. The efficiency of driver should be 85%, and THD 10% with minimum 4 KV surge protector complete with connection with PVC insulated copper wire of suitable size etc. i/c buyback of old dismantled material etc. as required.

20

11208

224160

... More
Supply and replacement of 2'x2' LED fitting and frame 600mmX600mm (N.S) of 40-42 watt with HET Diffuser, following type white powder coated CRCA housing having minimum 4000 lumens and colour temperature of 5500 to 6500 kelvin, and CRI of 80, with APFC driver, power factor 0.95,THD 10% and driver efficiency 85%.Luminire should have minimum efficacy of 100 lumens/watt,(The LED chip should be of Nichia, cree, Lumiled, OSRAM, seoul The Luminire shall operate on a voltage range of 150-270v, with minimum 2.5kv surge protection. Submission of LM80 report with a life of 50000 hours @ L70 and LED Photo biological safety report confirming to IEC62471 and from LED source manufacturer & LM79 report from NABL accredited Laboratory is mandatory complete with connection with PVC insulated copper wire of suitable size etc. as required i/c connection dismantling of old fitting and buyback of old dismantled material etc. as required. A) 40-42 watt suface/Recess mounted LED Fitting

100

3879

387900

... More
Supplying and replacement of 40 watt flying insect killer with complete UV tube, insect catch bug zapper replellent machine, high voltage current rectifier of size not less than 40 mmX 100 mm X 330 mm and full metel body weight not less than 6 kg i/c connection with proper 3 core cupper conductor cable i/c with heavy duty dash fastener and plug top etc. testing and commissioning and buy back the dismantled unit as required.

30

4253

127590

... More
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. A) 1 run of cable

100

59

5900

... More
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS: 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise-75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.

100

2824

282400

... More
Supplying, Installation, testing and commissioning of 300/400 mm Sweep wall mounted oscillating Fan suitable for 230 V 50 Hz Ac Supply complete with all accessories on existing wall etc. & dismantling and buyback of old existing fan etc. as reqd.

30

2901

87030

... More
Supply, installation, testing & commissioning of 300 mm (Heavy duty) sweep exhaust fan 900 RPM in the existing opening including making good the damages, connection testing and commissioning etc. complete and dismantling and buyback of old existing exhaust fans etc. as required.

30

4235

127050

... More
Supplying and fixing Cable End Box (Loose wire box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.

6

1210

7260

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.

800

72

57600

... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.

6

7730

46380

... More
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.

10

6472

64720

... More
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. A) 3½ X 25 sq. Mm

4

2564

10256

... More
3½ X 35 sq. mm

4

2564

10256

... More
3½ X 50 sq. mm

4

2564

10256

... More
3½ X 70 sq. mm

4

3479

13916

... More
3½ X 95 sq. mm

4

3639

14556

... More
3½ X 120 sq. mm

4

4695

18780

... More
3½ X 185 sq. mm

4

4695

18780

... More
3½ X 300 sq. mm

4

6318

25272

... More
3½ X 400 sq. mm

4

8242

32968

... More
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : A) 240 sq. mm

4

16811

67244

... More
Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : A) 240 sq. Mm

4

43341

173364

... More
PUMP WORKS Disconnecion & Lifting of following capacity Submersible pump set from the borewell along with GI pipe, Cable with the help of Chain pulley and tripod stand i/c disconnection of pipe , cable etc. complete as reqd (Upto 160 Ft). A) Upto 7.5 HP

3

2425

7275

... More
Disconnecion & Lifting of following capacity burntout / defective Openwell Submersible pump set from the UG Tank along with GI pipe, Cable with the help of Chain pulley and tripod stand i/c disconnection of pipe , cable etc. complete as reqd. A) Upto 25HP

4

2425

9700

... More
Lowering of 05 HP Capacity Submersible pump set in the existing borewell along with GI pipe, Holding Wire, Cable with the help of Chain pulley and tripod stand i/c clipping the Holding wire & Cable etc. complete as reqd. (Upto 160 ft) A) Upto 25HP

4

2504

10016

... More
Fabricating, Supplying and Fixing of following sizes, C-class G.I pipe of 6.0 Mtr lenght pipe with heavy duty GI flanged both side i/c rubber packing Nuts and bolts complete including anticorrosive paint on thread portion and cutting drilling hole in flange welding to avoide rusting etc. as reqd. a) 50 mm dia GI Pipe

100

1227

122700

... More
Supplying & fixing offollowing sizes flate type submersible cable with clamps along with delivery line i/c dismantling the existing defective submersible cable & buy back of defective submersible cable etc. as required. a) 3 X 2.5 Sq. mm Submersible Cable

100

378

37800

... More
Supplying, installation, testing and commissioning of following capacity fully automatic star delta starter suitable for Monoblock/Submersible Pump with Ameter & Single Phasing , Low Voltage, High Voltage Protectioni/c proper connectioning with tsuitable size copper himbles including dismentling the existing burnt out stater and buyback etc. as required. (A) 5 HP Fully Automatic Star Delta Starter

2

7233

14466

... More
B) 7.5 HP Fully Automatic Star Delta Starter

2

8231

16462

... More
C) 10 HP Fully Automatic Star Delta Starter

2

7632

15264

... More
D) 25 HP Fully Automatic Star Delta Starter

2

17205

34410

... More
Supply of Materials Supply of following material / accessories for using existing man power for replacement on day to day maintenance work: a) 5 Amp Piano type Switch

50

10

500

... More
b) 5 Amp Piano type Socket

50

24

1200

... More
c) 15/16 Amp Piano type Switch

50

50

2500

... More
d) 15/16 Amp Piano type Socket

50

62

3100

... More
e) 5 Amp Modular Switch

200

35

7000

... More
f) 5 Amp Modular Socket

160

65

10400

... More
g) 15/16 Amp Modular Switch

200

77

15400

... More
h) 15/16 Amp Modular Socket

200

109

21800

... More
i) 6 to 32 Amp SP MCB

120

140

16800

... More
j) 16 Amp DP MCB

60

452

27120

... More
k) 32 Amp DP MCB

60

452

27120

... More
l) 63 amp 4 pole Isolator

32

687

21984

... More
m) 100 amp 4 pole Isolator

16

838

13408

... More
n) Modular switch type regulator stepped

40

228

9120

... More
o) 100 A, 16 kA, TPMCCB

4

2735

10940

... More
p) Modular bell push, ISI marked

40

64

2560

... More
Sub Head -II : Sub Station & D.G.Sets A) Operation and Maintenance Providing services for running, operation & maintenance of Sub Station equipments consisting of HT & LT equipments & D.G. Sets in three shifts on all days round the clock i/c Sunday and holidays i/c cleanliness of equipments, installations & surroundings as per direction of Engineer-in-Charge and as per terms & conditions attached etc complete as required by deputing following staff: Sub - Station LBS Hospital Staff required: 1) Operator cum Wireman - 3 Nos.(one in each shift) 2) Khallasi - 1 No. (In General Shift 9 AM to 5 PM all days excluding Sunday)

24

146687

3520488

... More
Annual contract for maintenance of 1 no of 750 KVA Cummins make DG set of Model KTA -38-G2 750 KVAinstalled at 100 bedded LBSH Khichripur Delhi complete with AMF panel i/c general check up at least one visit monthly ,preventive maintenance of diesel engine,engineer/mechanic shall attend as and when breakdown will be reported ,alternator and AMF panel etc for smooth running of DG sets as required at site.-1 Job

24

11250

270000

... More
Supplying and replacement of following accessories for Periodically maintenance of 750 KVA Cummins make DG Set of Model KTA -38-G2 including buyback of dismantled material A) Element Lub Oil Filter (CIL Part No. KIT 32388204)

16

1133

18128

... More
KIT Fuel Filter and Ring (CIL part no. KIT 3238493)

8

1601

12808

... More
KIT Super BYP Filter Elem (CIL part no. KIT 3879488)

8

2344

18752

... More
Inhibitor Corrosion (CIL part No. 3816986)

4

2660

10640

... More
ELEMENT,AIR CLEANER (3238665)

4

30725

122900

... More
Foil Sealed Test Strips (3403800)

4

436

1744

... More
INDICATOR RESTRICTION (3872813)

4

876

3504

... More
SEAL,O RING (3010937)

8

33

264

... More
Inhibitor Corrosion 10 liters(4926654)

40

5148

205920

... More
Radiwash 3 Ltr(AX1013359)

20

5142

102840

... More
Funnel Dual Filte Conduction -L(AX1015648)

4

19030

76120

... More
Premium Blue 7800 PLUS 1

480

762

365760

... More
B) Routine and Repair Maintenance Work Complete Checking and Calibration of following various type of safety relays installed in the HT panel with secondary injunction test set i/c Overhauling, Checking and Removal of minor defects and co-ordination of relay settings as reqd. 3.1 (a) IDMT relay (2 O/C, I E/F) UE

8

2150

17200

... More
Servicing of 11 KV 630 Amp, 350 MVA, 3 phase metal clad Vacuum Circuit Breaker complete with removal from the HT panel board, dismantling / opening the required parts for servicing, checking, cleaning, testing & rectification of defects, oiling, greasing, assembling i/c moisturization of bur bar & CTs with the help of suitable equipment etc. complete as required.

4

4473

17892

... More
Servicing of 430V 800/1000/1250 amps. 3 phase 50 Hz air circuit breaker i/c drawing out the ACB, cleaning of components, decarbonising of the arcing chamber, setting right the mechanism, lubricating the moving parts, checking & testing the continuity of control wiring, tightening of connections, measuring the insulation test resistance with LT insulation tester, measuring the contact resistance of moving & fixed contacts, replacement of minor worn out parts like nut bolts & spring washer etc., reinstallation, testing etc. complete as reqd.( Part / component required to be replaced shall be paid extra as per actual)

32

3034

97088

... More
Supply and replacement of following defective parts in the existing HT panel i/c control wiring thumbing , connection testing and commissioning and credit/buy back of old etc as required. A) LED Indicating light

8

163

1304

... More
Complete Servicing of 1250 KVA, 11/0.415 KV 50 Hz dry type transformer complete with cleaning, checking of microprocessor based protection system, Hipot testing of HT winding and maggering of LT winding etc. as reqd.

4

13606

54424

... More
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. A) 125 Amp, 16 KA, TPMCCB

8

4988

39904

... More
B) 200 A, 25 KA, TPMCCB,

4

11397

45588

... More
C) 250 Amp, 35 KA, TPMCCB

3

14361

43083

... More
D) 400 Amp, 35 KA, TPMCCB

2

22333

44666

... More
Supply of Materials Sub Station and DG Set Supply of 180 AH Battery for DG Sets, using existing man power for replacement on day to day maintenance work

2

16115

32230

... More
Sub Head III : HVAC, STAC and WTAC Works A) Operation of 3 X 140 TR Capacity Centralized AC Plant and Hot Water Generator system Providing round the clock services for Operation of 3 X 140 TR Capacity Centralized AC Plant and Hot Water Generator system on the all days i/c Sunday & Holidays complete with cleaning & sweeping of A.C. Plant rooms and AHU's including maintaining record/register of temperaure for Mortuary Cold Rooms etc. complete as required i/c providing cleaning and sweeping material and uniforms etc. of deployed staff. a) A.C. Operator – 03 Nos. (01 No. in each shift for 3 shifts) b) Khallasi – 02 Nos. (06 AM to 02 PM, 02 PM to 10 PM) - 01 Job i/c Sunday and Holiday as per terms and conditions attached.

24

183451

4402824

... More
Annual Comprehensive Maintenance of the 3x140 TR Capacity Voltas Make AC Plant with all accessories and routine servicing, regular maintenance, preventive maintenance of equipments and components and break down repairs as and when occurred, ensuring that system does not remain out of service for a period more than one hours etc. as reqd. (The successful tenderer shall keep the essential spares at site to avoid the delay in attending faults / maintenance)

24

114628

2751072

... More
B) WTAC & STAC Works Providing day to day Maintenance & Repair of WTAC, Split A.C. Unit of 1.5TR / 2.0TR capacity and Water Coolers/Mortuary Cold Room installed at various locations of LBSH i/c Overhauling of machine attending complaint i/c checking & cleaning of condenser, Cooling coil with suitable chemical & all necessary preventive maintenance, as and when reqd. by providing experienced & qualified staff as per terms and condition attached & as per the direction of Engineer-in-Charge & site requirement. Following minimum staff shall be provided by the contractor including Sundays & holidays:- (1) AC Mechanic - 1 Nos. ( from 9 AM to 5 PM) (2) Khallasi - 1 Nos.( from 9 AM to 5 PM) (08 Month x 1Years i.e. March to October)

16

76294

1220704

... More
C) Repairing /Servicing of HVAC/window/split AC Complete servicing of WTAC/STAC unit of 1.5 / 2.0 Tr capacity including dismantling the AC from its existing position i.e. various OPD's, Wards, ICU, OTs and various DA Dispensaries/Polyclinics etc, cleaning of evaporative and condensing coil with suitable chemical like coil cleaner, greasing of motor, cleaning of drain pipe and refixing the same on its existing position complete etc. as required.

319

890

283910

... More
Supplying & Charging of R-410a/R-22 refrigerant gas in existing following capacity WTAC / STAC unit i/c replacement of capillary tube & strainer, pressure testing, vaccumising, testing etc. complete as reqd. (For One years) A) In 2 TR capacity

40

2132

85280

... More
B) In 1.5 TR capacity

60

1933

115980

... More
Supplying & replacement of following capacity reciprocating/rotary type hermetically sealed compressor complete in the existing WTAC & STAC unit i/c repairing / rejoining of copper pipes, testing etc. & buy back the old etc. as reqd. A) 1.5 TR capacity

8

10935

87480

... More
2 TR capacity

4

12894

51576

... More
Supplying and replacement of PCB of remote control unit in the existing indoor unit of 2 TR/1.5TR Cap. STAC (Invertor Type)/WTAC of various makes i/c dismantling existing worn out PCB, connection, testing & buy back the old etc. as reqd. (as per sample)

30

3455

103650

... More
Supplying and replacement of outdoor unit of 1.5 TR capacity for existing split AC unit including connection with copper pipe, cables i/c buy back for credit of old units i/c testing and commssioning complete etc as requried.

6

19598

117588

... More
Supplying and replacement of indoor unit of 1.5 TR capacity for existing split AC units with remote i/c connection with copper pipe cablesi/c buy back for credit of old units i/c testing and commissioning complete etc as required.

6

10539

63234

... More
SITC of hard drawn copper suction and discharge refrigeration pipe of size 5/8"and 3/8" suitable for 1.5 TR / 2 TR STAC duly insulated by nitrile rubber along with 3 core x 2.5 Sq.mm. copper cable & than inserted in the PVC flexible pipe with necessary support as required as per site requirement., testing i/c less credit of old dismantle material complete etc as reqd.

260

1352

351520

... More
Supplying, installation, testing & commissioning of split type air conditioning unit of nominal cooling capacity ≥6100 watt and ISEER ≥3.80 comprising of condensing coil & evaporating coil made out of copper tube & aluminium fins, condenser fan & evaporator blower with motors, remote control unit, filter etc. suitable for operation on 230 Volts, single phase 50 Hz AC supply including providing & fixing copper refrigerant suction discharge piping with insulation & control cable upto 4 mtr length etc. complete as reqd at site.

2

58205

116410

... More
Supplying, installation, testing & commissioning of split type air conditioning unit of nominal cooling capacity ≥5000 watt and ISEER ≥3.80 comprising of condensing coil & evaporating coil made out of copper tube & aluminium fins, condenser fan & evaporator blower with motors, remote control unit, filter etc. suitable for operation on 230 Volts, single phase 50 Hz AC supply including providing & fixing copper refrigerant suction discharge piping with insulation & control cable upto 4 mtr length etc. complete as reqd at site.

2

51364

102728

... More
Supplying, installation, testing & commissioning of Window type AC unit of nominal cooling capacity ≥ 4800 watt, ISEER ≥ 3.10 comprising of condensing coil & evaporating coil made out of copper tube & aluminium fins, condenser & evaporator fan / blower with motor, remote control unit, filter etc. suitable for operation on 230Volt 1-Ph 50 Hz, AC supply i/c providing & fixing wooden frame, ply for blocking the space in the existing window where ever required complete etc. as required at site.

4

30427

121708

... More
Sub Head - IV : Fire Fighting and Fire Alarm System A) Operation and Maintenance Fire Fighting and Wet Riser System: Providing services for running, operation & maintenance of Fire Fighting system at LBS Hospital in three shifts round the clock on all days i/c Sunday & holidays i/c weekly fire testing testing and maintaining the register, cleanness of equipments, installations & surroundings as per direction of Engineer-in-Charge and as per terms & conditions etc complete as required by providing the following staff:- (1) Operator cum wire man - 3 Nos. (1 in each shift) (2) Khalllasi - 3 Nos. (1 in each shift)

24

215922

5182128

... More
B) Routine and Repair Maintenance Work Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required. A) 150mm dia

2

18401

36802

... More
100mm dia

2

11432

22864

... More
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : a) Single headed Stainless steel

4

6351

25404

... More
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. a) 30 m

4

8975

35900

... More
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : a) Stainless Steel (Grade 304)

6

1719

10314

... More
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. a) 150 mm. Dia

20

3936

78720

... More
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required. a) Single headed Stainless steel

4

6351

25404

... More
Sub Head - V : Fire Alarm System A) Operation and Maintenance Fire Alarm System: Providing services for running, operation & maintenance of Fire Alarm system at LBS Hospital in three shifts round the clock on all days i/c Sunday & holidays i/c weekly fire testing testing and maintaining the register, cleanness of equipments, installations & surroundings as per direction of Engineer-in-Charge and as per terms & conditions etc complete as required by providing the following staff:- (1) Operator cum wire man - 3 Nos. (1 in each shift)

24

118508

2844192

... More
B) Routine and Repair Maintenance Work Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required. A) 10 zone panel.

2

16850

33700

... More
B) 6 zone panel.

3

12599

37797

... More
C) 4 zone panel.

6

9173

55038

... More
Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required.

15

203

3045

... More
Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required.

20

1193

23860

... More
Supplying, installation, testing & commissioning of heat detector operating at 54ºC/57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required.

30

1108

33240

... More
Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in A.B.S. box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.

30

508

15240

... More
Supplying, installation, testing & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.

20

422

8440

... More
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.

600

179

107400

... More
Sub Head - VI : EPBAX System Comprehensive maintenance & services of Electronic Private Automatic Exchange having 8 lines with all the standard features and maintenance of push button telephone intercom instruments upto 8 nos. i/c replacement of all spare parts/components as and when required ( At sub division office) - 1Job.

24

2047

49128

... More
Comprehensive maintenance & services of Electronic Private Automatic Exchange having 16 lines with all the standard features and maintenance of 10 no. push button telephone instruments i/c replacement of minor spare parts/components as and when required ( At Sub division office and Mayur Vihar Phase 1 ) - 2 Jobs.

24

5986

143664

... More
Sub Head - VII : STP/ETP Operation Operationn and Routine Maintenance, Proper Cleaning and Day to day Operation of 125 KLD MBR Technology Base STP Plant and management of Sewerage into Equalization Cum Collection Tank i/c all repair works as per requirement of proper functioning of Plant on all working days and top up AIR compressor with gear oil i/c Sundays and holidays complete by deputing round the clock 1) 02 Nos. Skilled Operator in 2 shift (06 AM to 2 PM and 2 PM to 10 PM) i/c Sunday and Holiday as per terms and conditions attached. 2) Khallasi 01 No. in general shift

24

111477

2675448

... More
Sub Head - VIII : Operation of Lift A) Operation Lift Providing services for running, operation & General maintenance of LBS Hospital in three shifts round the clock on all days i/c Sunday & holidays i/c cleanness of equipments, installations & surroundings as per direction of Engineer-in-Charge and as per terms & conditions etc complete as required by providing the following staff:- (1) Operator - 3 Nos. (1 in each shift)

24

118508

2844192

... More
Comprehensive, maintenance of OTIS make hospital cum bed lift of capacity 20 person having speed of 0.5 mtr/sec installed at Lal Bahadur Shastri Hospital, Khichripur Delhi, Serving five floors (Ground + 4th Floor) as per terms & conditions attached - 1 job

24

19889

477336

... More
Sub Head - IX : LAN System and CCTV Cameras A) LAN System Comprehensive Maintenance of Juniper make Networking System & LAN System i/c all services, cleaning for checking repair & replacement of minor/major defective parts of with following scope of work: 1) Juniper Network Layer 3 10/100/1000-24 ports Giga Edge Switches 2 nos., 2) Juniper 10/100/1000-24 ports Giga Edge Switches 15 nos., 3) Fortigate Firewall system : 01 Nos 4) Cisco Network Router : 01 Nos 5) Poweride Network 9 U Racks,: 08 Nos 6) Poweride Network 32 U Rack: 01 Nos 7) D-link SFP Modules 25 Nos, 8)D-link Jack Panel 10 Nos, 9) D-link SM 6 port LIU : 06 Nos 10) D-link SM 12 port LIU : 04 Nos 11 D-link SM 24 Port LIU : 02 Nos 12) CAT-6 Low Smoke UTP cable: 8000 Mtrs 13) Schneider 6 core OFC cable : 650 Mtrs 14) D-link 1mtrs &2 Mtrs UTP Low Smoke Patch Cords : 345 Nos along with all accessories Excluded Plastic Trunking & Earthing Except Force Damage. -01 Job

24

61170

1468080

... More
B) CCTV Cameras Comprehensive maintenance of CCTV system of Panasonic make installted at LBHS Hospital , Khichripur , Delhi Having following accessories i. e. 1)Panasonic IP Based Bullet Camera : 28 Nos. 2) Panasonic IP Based Dome Camera: 45 Nos. 3) Panasonic IP Based PTZ Camera: 05 Nos. 4) Panasonic 64 Ch NVR system : 01 Nos 5) Panasonic 16 Ch NVR system : 1 No. 6) Work Station: 02 Nos. 7) 24 port Network Switch: 10 Nos. 8) 9 U Network Rack: 7 Nos. 9) LED Dispaly 32 Inches : 05 Nos. 10) Numeric 5KVA UPS : 01 No. 11)Panasonic IP Based Bullet Camera : 32 Nos. 12) Panasonic 16 Ch NVR system : 02 Nos 13) Work Station: 01 No. 14) 24 port Network Switch: 04 Nos. 15) 9 U Network Rack: 03 Nos. 16) Microteck 1 Kva UPS system : 10 Nos

24

92743

2225832

... More
Providing round the clock services for CCTV Surveillance system complete with CCTV/LAN System , NVR system , LED Display, Network switches and other accessories intalled at LBHS Hospital , Khichripur , Delhi i/c Sunday & Holidays by deputing the following staff a) Operator - 3Nos (1 no.in each shift)

24

118508

2844192

... More
Sub Head - X : AMC & Operation of 2X1000 LPH RO Plant and RO Inbuilt water cooler/ dispenser system A) AMC and Operaton Work of 2X1000 LPH RO Plant RO Inbuilt water cooler/ dispenser system Annual comprehensive maintenance contract of ICON Make RO plant 2x1000 LPH capacity installed at LBSH including all electrical and electronics spares i.e. starter, rotameter, MCB, pH meter, TDS meter, washing, rinsing of sand filter, rinsing of activated carbon filter, one time replacement of appropriate quantity of gravels & pebbles of all sizes, activated carbon, multiport valve, all pipe fittings, dosing pumps, electronic panels, TFC membranes, anti-scalent chemical and big blue micron filter, i/c overhauling of pump sets, replacement of bearing, replacement of water seals, gasket, replacement of damaged pipe lines and its accessories etc. as required to make RO plant to work smoothly and satisfactorily every month. (Consumable to be replace as and when required after expiry of the working life will be extra)

24

15877

381048

... More
Operating servicing etc. of moles system comprising of operating of the unit i.e. skilled operator for operating the R.O. units capacity -2X1000 LPH already installed at LBSH. The operator should be trained to operate RO Plant and backwash, Cleaning of Prefilter etc. in exiting plant, the work carried during 9:00 AM to 5:00 PM in Genral Shift excluding Sunday/Holiday etc. as reqd. at site.

24

34272

822528

... More
Annual Comprehensive Maintenanace of Water Cooler with inbuilt RO +UV of ATSIN Make with capacity 150 Ltr Storage Capacity and 150 ltr cooling capacity with 100 LPH RO System connected with water tank consisting of three mandatory Services, Repair/Replacement of all electrical and electronic spare parts like Speed Pump , Solenoid Valve, high pressure Switch, SMPS, adoptor and Attending complaints within 24 working hours with complete overhauling and servicing etc as reqd. (12 Nos For 24 Months)

288

6316

1819008

... More
Annual Maintenance Contract of Hot , Cold & Normal Water Dispenser with inbuilt RO+UV with system Connected with storage tank consisting of three Mandatory Services, Repair/Replacement of all Electrical and Electronic Spare parts like Pump , SMPS, Adaptor , Solenoid Valve and High Pressure Switch and attending complaints within 24 working hours with complete overhauling and servicing etc as reqd (10 Nos For 24 Months)

240

1613

387120

... More
Repair/ Replacement & Major Maintenance Work Replacement of 4" X 40" RO Membrane (Make: Dow /CSM/ Hydronautics/Vontron/Filtek)

24

12650

303600

... More
Replacement of Big Blue Micro Filters of dia 20" X 4" up to filtration of 5 Micron (Make Chemflo /Hi-tech / Razor/Darlay/Icon)

48

689

33072

... More
Replacement of Micro Filters Bag of dia 20" X 4" up to filtration of 5 Micron

48

344

16512

... More
Antiscalent Chemical ( Make: Alkaline base)

400

362

144800

... More
Providing and arrangement of Treated Water Test Report from any DPCC authorized laboratory with following parameters to be tested. (After every six month) a) TSS b) BOD (Bio-Chemical Oxygen Demand) c) Oil and grease d) pH. e) Bio-Assay Test i/c Charges towards water input sample collection and got tested report etc. as required at site

4

9800

39200

... More
Supplying and Replacement of Following Spare/Components in the exisiting water Dispenser & Water Cooler with inbuilt RO+UV etc as reqd. (Make ATSIN) A) TFC Cartridge 1812 (For 10 Nos. dispenser X 2 Each in 6 Months)

120

5184

622080

... More
TFC Cartridge 4021 (For 12 Nos. RO+Water Cooler X 2 Each in 6 Months)

144

39721

5719824

... More
Particulate Filter 20" (For 12 Nos. RO+Water Cooler X 2 Each in 6 Months)

144

1364

196416

... More
Activated Carbon 20" (For 12 Nos. RO+Water Cooler X 2 Each in 6 Months)

144

1508

217152

... More
Particulate Filter 10" (For 10 Nos. dispenser 1 each in 6 Months)

40

755

30200

... More
Activated Carbon 10" (For 10 Nos. dispenser 1 each in 6 Months)

40

785

31400

... More
Alkaline Filter (For 12 Nos. RO+Water Cooler X 1 Each in 6 Months)

60

5493

329580

... More
Alkaline Filter for dispenser (For 10 Nos. dispenser 1 each in 6 Months)

40

881

35240

... More
Supplying and Charging of R 134 Gas charging in the water Dispenser with inbuilt water purifier after pressure testing leak detection and rectified the breakage (if any) testing and commissioning etc as reqd.

8

3119

24952

... More
Supplying and Charging of R 134 Gas charging in the water Cooler for 150/150 with inbuilt water purifier after pressure testing leak detection and rectified the breakage(if any ) testing and commissioning etc as reqd.

8

8450

67600

... More
Sub Head - XI : Comprehensive Maintenance and Operation of mixed Oxidant Plant A) Comprehensive Maintenance and Operation of mixed Oxidant Plant Providing services of operation and routine maintenance of Aquapro make plant two sets of mixed oxidant based plants alongwith allied machinery and water filtration plant with high precision metering system installed in main park at LBS Hospital, Khichripur, Delhi the job shall be included as under: a) Round the clock operation with provide 1 No. operator cum mechanic in each shift. i.e. 03 Nos. b) Charging of High grade reined industrial salt (30Kg/Plant per month). c) Charging of Orthophosphate based cleaning chemical for cell. (5 Ltr. Per month). d) Testing of chlorine estimation with test chemical.

24

129705

3112920

... More
Supplying, cleaning of Regenerating chemical for Aquapro make water softening plant & its allied accessories at LBSH, which includes charging of water softening Plant with brine (Solution of common grade industrial salt) Qty: 60 Kg/Charging at periodic intervals i.e. 26 times a month to keep the output hardness of water within acceptable limits. The averaged requirement of charging shall be app. 26 per Month. It shall be within the scope of work to replace any component/ part/ chemical that may be the part of water softening system but not mentioned above. The Chemical to test the Raw water soft water before & after charging are including in the scope of work. (1560 Kg per Month)

24

24195

580680

... More
Supply and replacement of strongly Acidic Cationic Resin to the pressure vessel of softner for processing of water. AQUAPRO Make Capacity :20 Cu.m/Reg Quantity :400 Ltrs Make: Indion 220 Na/ Rohm Hass Or Equivalent

600

264

158400

... More
Sub Head - XII :Various Delhi Govt Dispensary /Polyclinic A Maintenance Work Providing services one shift from 9AM to 5 PM on all days except Sunday & holidays for day to day maintenance of electrical installation, street light, Panel and other electrical accessories at under mentioned buildings i/c cleanliness of equipments, installation & surroundings as per terms & condition as per the direction of Engineer-in-charge etc complete as required by providing following staff:- DGD Mayur Vihar Phase 1, DGD Trilokpuri, DGD Himmat Puri, DGD Kalyanpuri, DGD Mandawali, Polyclinic Vasundhara Enclave, Polyclinic Kondli, Polyclinic Kalyanvas, Polyclinic IP Extn, Veterinary Hospital Ghazipur, Delhi Staff Required: (1) Wireman - 1 No. (2) Khallasi - 1 No.

24

62451

1498824

... More
Sub Head - XIII : Dismantle Materials Dismantling of following wornout materials from existing position and credit under buy back : A) Assorted size of SPN DB

5

150

-750

... More
Assorted size of TPN DB

5

250

-1250

... More
Assorted size 16/32/40/63 amp DP MCB/RCCB

80

10

-800

... More
Assorted size 6/10/16/32 amp SP MCB

100

5

-500

... More
Assoeted 5 Amp/16 amp Modular Switch/Piano Switch/Modular bell push

350

-

-35

... More
Assorted 5 Amp/16 amp Modular Socket/Piano Socket

500

-

-75

... More
Assorted modular/piano type regulator

30

-

-3

... More
Assorted 1200/1400 mm ceiling fan

80

200

-16000

... More
Assorted 100 amp TPN MCCB

10

50

-500

... More
Assorted 100 amp TPN MCB

20

30

-600

... More
Assorted 125 amp/200 TPMCCB

10

200

-2000

... More
Assorted 250 amp/400 TPMCCB

3

350

-1050

... More
1.5 TR Capacity Window AC

4

3000

-12000

... More
1.5 TR/2TR Capacity Split AC

10

4000

-40000

... More
Compressor

12

1000

-12000

... More
Assorted PCB

30

50

-1500

... More
Assorted PVC pipe

10

30

-300

... More
Assorted MS pipe/ sheet

50

50

-2500

... More
NRV of 150 mm/100 mm

4

500

-2000

... More
Sector Panel of 10/6/4 Zone

10

250

-2500

... More
Assorted RI/Smoke/Heat Detector

60

5

-300

... More
Assorted Fire Alarm Sounder/MCP

40

10

-400

... More
Internal/External Hydrant Valve

4

200

-800



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.