Public Works Department Tender
... More
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Public Works Department - PWD Tender
Machinery and Tools
Electrical and Electronics
Electrical Works
Eprocure
Opening Date29 Apr 2025
Closing Date6 May 2025
Tender Amount₹ 46,78,250
Costs
EMD
₹ 93,565Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_PWD_271424_1Bid Award Id
ViewTender No
14/2025-26/EMD M-351/EE(E)Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://https://www.pwddelhi.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
i) Higher skilled labour for sub station i.e Electrician / Foreman - 3 Nos. (Round of Clock) (1 No. in each shift)
ii) Khallasi - 1 No. (General Shift)
12
135803
1629636
... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
-
-
-
... More
3 x 1.5 sq. mm
200
95
19000
... More
3 x 4 sq. mm
150
206
30900
... More
3 x 6 sq. mm
100
304
30400
... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
-
-
-
... More
20 mm
50
128
6400
... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
-
-
-
... More
5/6 amps switch
200
103
20600
... More
15/16 amp switch
100
156
15600
... More
3 pin 5/6 amp socket outlet
100
122
12200
... More
6 pin 15/16 amp socket outlet
100
197
19700
... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
100
369
36900
... More
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.
-
-
-
... More
3 Module
50
151
7550
... More
6 Module
40
182
7280
... More
8 Module
30
211
6330
... More
12 Module
20
272
5440
... More
3 Module Plastic surface Box
20
70
1400
... More
6 Module Plastic surface Box
15
132
1980
... More
8 Module Plastic surface Box
12
245
2940
... More
12 Module Plastic surface Box
8
218
1744
... More
Fan condenser 2.5 MFD
50
112
5600
... More
6 A Plug-Top
50
148
7400
... More
15 A Plug-Top
25
177
4425
... More
25 A Plug-Top
50
241
12050
... More
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required.
30
727
21810
... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
... More
Single pole
85
256
21760
... More
Supplying, Installation, Testing and Commissioning of 200 mm sweep fresh air fan working on 230 +/- 10 V single phase 50 Hz Frequency complete with shutter in existing hole of suitable size making good the same i/c connections, interconnections etc. complete as reqd.
40
1422
56880
... More
Supplying, Installation, Testing and Commissioning of 250 mm sweep fresh air fan working on 230 +/- 10 V single phase 50 Hz Frequency complete with shutter in existing hole of suitable size making good the same i/c connections, interconnections etc. complete as reqd.
40
1494
59760
... More
Supplying, Installation, Testing and Commissioning of 300 mm Sweep 900 RPM Heavy Duty ISI Marked Exhaust fan with louvers & shutters in the existing opening, including making good the same, connection, testing, commissioning etc. as reqd.
4
3731
14924
... More
Supplying, Installation, Testing and Commissioning of 400 mm Sweep wall Fan suitable for 230 V 50 Hz Ac Supply complete with all accessories on existing wall etc. complete as required.
25
2405
60125
... More
Supply, Installation, Testing and Commissioning of BEE rated, ceiling fan with squirrel cage induction Motor, class of insulation: B, 3 nos. metal( Aliminium alloy blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body, Power Factor not less than 0.9 , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit of suitable wattage for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as reqd.
-
-
-
... More
1200mm, BEE 3 star rating, service value ≥5.0 to 5.5 CM/Min/Watt, air delivery 210 CM/Min ( Minimum)
40
2597
103880
... More
1400mm, BEE, service value ≥5.0 to 5.5 CM/Min/Watt, air delivery 210 CM/Min ( Minimum)
40
2498
99920
... More
Supplying, installation, Testing & Commissioning of LED surface mounted Batten light, powder coated die cast aluminium /polycarbonate body with built in driver ( 750ma),Operating voltage AC 100-240 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD 10% , P. F.≥0.95, IP20, CRI 80 , life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard (As mentioned in Bottom Note)and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. "complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required" , (LM79 & LM80) certificate / Report from OEM shall be submitted. Minimum 5 year OEM warranty, . Shape size and CCT shall be as approved by Engineer in charge. System lumen efficacy system lumen efficacy ≥105 and 120 lm/Watt output. All as per pre approved by Engineer-in-charge
-
-
-
... More
36-40 watt (1200 mm 4 feet )
80
1403
112240
... More
Supplying, installation, Testing & Commissioning of Surface / recessed Panel Down light 1x4 ft., powder coated die cast aluminium/polycarbonate body with built in driver (750ma), Operating voltage AC 100- 240 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD 10% , P. F.≥0.95, IP20, CRI 80, life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard (As mentioned in Bottom Note)and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted,Minimum 5 year OEM warranty, . Shape size and CCT shall be as approved by Engineer in charge. System lumen efficacy ≥105 and 120 lm/Watt output All as per pre approved by Engineer-in-charge. i) 36 watt
75
4481
336075
... More
Supplying, installation, Testing & Commissioning of Surface / recessed Panel Down light 2x2 ft., powder coated die cast aluminium/polycarbonate body with built in driver (750ma), Operating voltage AC 100- 240 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD 10% , P. F.≥0.95, IP20, CRI 80, life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard (As mentioned in Bottom Note)and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted,Minimum 5 year OEM warranty, . Shape size and CCT shall be as approved by Engineer in charge. System lumen efficacy ≥105 and 120 lm/Watt output All as per pre approved by Engineer-in-charge
-
-
-
... More
36 watt
75
2913
218475
... More
Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in driver (700ma), Input voltage: Input voltage: 100-240 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency 85%,THD 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-65,IK-08, CRI 80 , under voltage and over voltage protection,EMI-EMC As per CISPER 15 A, lenses for beam angle 45* 120 deg., suitable tilt able fitting, life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. "complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required" , (LM79 & LM80) certificate / Report from OEM shall be submitted. Minimum 5 year OEM warranty, . Shape size and CCT shall be as approved by Engineer-in-charge. System lumen efficacy ≥120 and 135 lm/Watt output All as per pre approved by Engineer-in-charge ( Thermal management: heat sink of aluminium housing. aluminium metal-core printed board of thermal conductivity more than 2.0W/mk and thermal pad with thermal conductivity more than 1.5W/mk) etc. as required.
-
-
-
... More
150 watt
15
8291
124365
... More
Credit for old dismental items
-
-
-
... More
Assorted copper wire
3
400
-1200
... More
Assorted Switch/Socket/fan regulator/modular base & cover plate/Box/fan condenser/top
450
-
-225
... More
Assorted MCB
90
10
-900
... More
Assorted Fresh air fan/exhaust fan
100
250
-25000
... More
Assorted ceiling fan
60
300
-18000
... More
Assorted fitting
200
100
-20000
... More
Assorted flood light
7
250
-1750
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements