Public Works Department Tender

If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Public Works Department - PWD Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date14 Nov 2024
Closing Soon22 Nov 2024
Tender Amount₹ 7,18,894 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Replacement of defective flood light by Supplying of 70-80 watt LED Flood Light fitting aluminium die cast housing ,IP 65 with high power LED as light source, system lumen efficiency of ≥ 120 lm/W, min lumen output 8000 lumens colour rendering (CRI) ≥ 70, and correlated colour temperature (CCT) of 5500 - 6500 (±300K). The luminaries should have 10KV surge protection, PF≥0.95, the total harmonic distortion≤ 10% operatable in voltage range of 220-270 V, total burning hours 50000 with LM 70/79/80 Certificates The driver used must be a constant current driver with efficiency of ≥ 85% and driving current ≤ 725mA complete r on surface with suitable fasteners as required and as per direction of Engineer-In charge. i/c dismantling of existing fittings. Complete etc. as reqd.

6

8264

49584

... More
Supplying, Installation, Testing & Commissioning 1200 mm long high efficiency LED linear batten Luminaries having lumens output 2000 and power not more than 20 watt made out of aluminum extruded housing and polycarbonate diffuser within built APFC driver having efficiency of driver 85% power factor 0.90, THD 20% with minimum 2.5 KV surge protection, LED life with L-70 criteria shall be not less than 50000 burning hours etc. suitable for operation on 150 to 265V single phase A.C. supply, having system efficiency 120 luman per watt and colour temperature of 6000 K, CRI 80 including connection with 1 5 sq. mm PVC insulated copper conductor FRLS cable etc. Complete as required.

120

760

91200

... More
Replacement of defective box by Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess i/c dismentling the existing etc. as required.

-

-

-

... More
3 Module (100 mmX75 mm)

25

327

8175

... More
6 Module (200 mmX75 mm)

15

402

6030

... More
12 Module (200 mmX150 mm)

15

547

8205

... More
Replacement of defective Switch/socket by Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (Anchor Roma)

-

-

-

... More
5/6 A switch

30

103

3090

... More
3 pin 5/6 A socket outlet

10

122

1220

... More
15/16 A switch

85

156

13260

... More
6 pin 15/16 amp socket outlet

85

197

16745

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.

-

-

-

... More
3 x 1.5 sq. mm

130

95

12350

... More
6 x 1.5 sq. mm

40

181

7240

... More
3 x 4 sq. mm

160

206

32960

... More
6 x 4 sq. mm

80

396

31680

... More
Supplying and fixing of following sizes of PVC conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

... More
a) 20 mm

120

128

15360

... More
b) 25 mm

75

145

10875

... More
Rewiring for light point/ fan point/exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. Group 'C'

160

894

143040

... More
Replacement of defective by Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)

-

-

-

... More
6 way, Double door

2

2206

4412

... More
8 way, Double door

2

2573

5146

... More
12 way, Double door

5

2315

11575

... More
Replacement of defective by Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.

-

-

-

... More
125 A, 16 kA, TPMCCB

2

4821

9642

... More
250 A, 25 kA, TPMCCB

1

12984

12984

... More
Replacement of defective by Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
Single pole

90

256

23040

... More
Single pole and neutral

9

599

5391



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.