Public Works Department Tender

If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Public Works Department - PWD Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date16 Nov 2024
Closing Soon22 Nov 2024
Tender Amount₹ 80,03,928 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Routine and Repair Maintenance Work i) EI Works. Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. a) Group A

5

1287

6435

... More
Group C

15

1909

28635

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. A) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire

30

338

10140

... More
2 X 4 sq. mm + 1 X 4 sq. mm earth wire

30

443

13290

... More
2 X 6 sq. mm + 1 X 6 sq. mm earth wire

15

609

9135

... More
4 X 4 sq. mm + 2 X 4 sq. mm earth wire

10

700

7000

... More
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required. A) Group A

5

594

2970

... More
Group C

20

925

18500

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.

10

606

6060

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a) 8 way, Double door

1

2662

2662

... More
12 way, Double door

1

2395

2395

... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator) a) 4 way (4 + 12), Double door

1

4233

4233

... More
8 way (4 + 24), Double door

1

6173

6173

... More
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) a) 12 way (4 + 36), Double door

1

13277

13277

... More
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

2

1677

3354

... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 63 amps

1

2816

2816

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required a) 63 mm dia (OD-63 mm & ID-51 mm nominal

5

256

1280

... More
90 mm dia (OD-90 mm & ID-76 mm nominal)

5

300

1500

... More
120 mm dia (OD-120 mm & ID-103 mm nominal)

5

381

1905

... More
160 mm dia (OD-160 mm & ID-135 mm nominal)

5

498

2490

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required. A) Upto 35 sq. mm

10

38

380

... More
Above 35 sq. mm and upto 95 sq. mm

5

59

295

... More
Above 95 sq. mm and upto 185 sq. mm

4

80

320

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing masonry open duct as required. A0 Upto 35 sq. mm

5

29

145

... More
Above 35 sq. mm and upto 95 sq. mm

5

47

235

... More
Above 95 sq. mm and upto 185 sq. mm

4

65

260

... More
Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 kV grade of following size on wall surface as required. A) Upto 35 sq. mm (clamped with 1mm thick saddle)

10

57

570

... More
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

5

134

670

... More
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/ 40x3mm MS flat clamp)

5

158

790

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. A) 150 mm width X 50 mm depth X 1.6 mm thickness

10

741

7410

... More
300 mm width X 50 mm depth X 1.6 mm thickness

10

996

9960

... More
Supplying and Replacement of defective Tube light fitting with energy efficient LED battens 18-22 Watt Watt Surface mounted fitting with extruded aluminium housing with output not less than 2000 lumen colour temperature not less than 5700 K suitable for operation on 230 Volt 50 Hz AC Supply directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing i/c buyback of old dismantled material etc. as required.

10

415

4150

... More
Supply and replacement of defective Tube light fitting with energy efficient LED battens 36 Watt Surface mounted fitting with extruded aluminium housing having output not less than 3500 lumen colour temperature not less than 5700 K suitable for operation on 230Volt 50 Hz AC Supply directly on ceiling/wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required i/c buyback of old dismantled material etc. as required.

10

2073

20730

... More
Supplying and replacement of 110-120Watt LED Flood light, having die cast housing , toughened glass and system out put of minimum 12000 lumens, having IP66 protection for complete housing. LED chip should have efficacy of 130lumens/watt, CCT of 5700k, CRI :70 and junction temperature of 135 degrees and having a life of 50000 hours with L70 Criteria. The efficiency of driver should be 85%, and THD 10% with minimum 4 KV surge protector complete with connection with PVC insulated copper wire of suitable size etc. i/c buyback of old dismantled material etc. as required. .

2

5018

10036

... More
Supply and replacement of 2'x2' LED fitting and frame 600mmX600mm (N.S) of 40-42 watt with HET Diffuser, following type white powder coated CRCA housing having minimum 4000 lumens and colour temperature of 5500 to 6500 kelvin, and CRI of 80, with APFC driver, power factor 0.95,THD 10% and driver efficiency 85%.Luminire should have minimum efficacy of 100 lumens/watt,(The LED chip should be of Nichia, cree, Lumiled, OSRAM, seoul The Luminire shall operate on a voltage range of 150-270v, with minimum 2.5kv surge protection. Submission of LM80 report with a life of 50000 hours @ L70 and LED Photo biological safety report confirming to IEC62471 and from LED source manufacturer & LM79 report from NABL accredited Laboratory is mandatory complete with connection with PVC insulated copper wire of suitable size etc. as required i/c connection dismantling of old fitting and buyback of old dismantled material etc. as required. A) 40-42 watt suface/Recess mounted LED Fitting

10

5436

54360

... More
Supplying and replacement of 40 watt flying insect killer with complete UV tube, insect catch bug zapper replellent machine, high voltage current rectifier of size not less than 40 mmX 100 mm X 330 mm and full metel body weight not less than 6 kg i/c connection with proper 3 core cupper conductor cable i/c with heavy duty dash fastener and plug top etc. testing and commissioning and buy back the dismantled unit as required.

4

3067

12268

... More
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. A) 1 run of cable

20

59

1180

... More
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS: 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise-75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.

10

2824

28240

... More
Supplying, Installation, testing and commissioning of 300/400 mm Sweep wall mounted oscillating Fan suitable for 230 V 50 Hz Ac Supply sompete with all accessories on existing wall etc. & dismantling and buyback of old existing fan etc. as reqd.

4

3137

12548

... More
Supply, installation, testing & commissioning of 300 mm (Heavy duty) sweep exhaust fan 900 RPM in the existing opening including making good the damages, connection testing and commissioning etc. complete and dismantling and buyback of old existing exhaust fans etc. as required.

4

3844

15376

... More
Supplying and fixing Cable End Box (Loose wire box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.

1

1210

1210

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.

100

72

7200

... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.

1

7730

7730

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

10

252

2520

... More
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. A) 3½ X 25 sq. Mm

1

2564

2564

... More
3½ X 35 sq. Mm

1

2564

2564

... More
3½ X 50 sq. mm

1

2564

2564

... More
3½ X 70 sq. mm

1

3479

3479

... More
3½ X 95 sq. mm

1

3639

3639

... More
3½ X 120 sq. mm

1

4695

4695

... More
3½ X 185 sq. mm

1

4695

4695

... More
3½ X 300 sq. mm

1

6318

6318

... More
3½ X 400 sq. mm

1

8242

8242

... More
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : A) 240 sq. Mm

1

16811

16811

... More
Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : A) 240 sq. Mm

1

43341

43341

... More
ii) PUMP WORKS Disconnecion & Lifting of following capacity Submersible pump set from the borewell along with GI pipe, Cable with the help of Chain pulley and tripod stand i/c disconnection of pipe , cable etc. complete as reqd (Upto 160 Ft). A) Upto 7.5 HP

1

2549

2549

... More
Disconnecion & Lifting of following capacity burntout / defective Openwell Submersible pump set from the UG Tank along with GI pipe, Cable with the help of Chain pulley and tripod stand i/c disconnection of pipe , cable etc. complete as reqd. A) Upto 25HP

1

2549

2549

... More
Lowering of 05 HP Capacity Submersible pump set in the existing borewell along with GI pipe, Holding Wire, Cable with the help of Chain pulley and tripod stand i/c clipping the Holding wire & Cable etc. complete as reqd. (Upto 160 ft) A) Upto 25HP

1

2549

2549

... More
Fabricating, Supplying and Fixing of following sizes, C-class G.I Colomn pipe of 6.0 Mtr lenght pipe with heavy duty GI flanged both side i/c rubber packing Nuts and bolts complete including anticorrosive paint on thread portion and cutting drilling hole in flange welding to avoide rusting etc. as reqd. a) 50 mm dia GI Pipe

10

1227

12270

... More
Supplying & fixing offollowing sizes flate type submersible cable with clamps along with delivery line i/c dismantling the existing defective submersible cable & buy back of defective submersible cable etc. as required. a) 3 X 4 Sq. mm Submersible Cable

10

257

2570

... More
Sub Head -II : Sub Station & D.G.Sets A) Operation and Maintenance Providing services for running, operation & maintenance of Sub Station equipments consisting of HT & LT equipments & D.G. Sets in three shifts on all days round the clock i/c Sunday and holidays i/c cleanliness of equipments, installations & surroundings as per direction of Engineer-in-Charge and as per terms & conditions attached etc complete as required by deputing following staff: Sub - Station LBS Hospital Staff required: 1) Operator cum Wireman - 3 Nos.(one in each shift) 2) Khallasi - 1 No. (In General Shift 9 AM to 5 PM all days excluding Sunday)

3

146687

440061

... More
Annual contract for maintenance of 1 no of 750 KVA Cummins make DG set of Model KTA -38-G2 750 KVAinstalled at 100 bedded LBSH Khichripur Delhi complete with AMF panel i/c general check up at least one visit monthly ,preventive maintenance of diesel engine, engineer/ mechanic shall attend as and when breakdown will be reported ,alternator and AMF panel etc for smooth running of DG sets as required at site.-1 Job

3

11250

33750

... More
Supplying and replacement of following accessories for Periodically maintenance of 750 KVA Cummins make DG Set of Model KTA -38-G2 including buyback of dismantled material A) Element Lub Oil Filter (CIL Part No. KIT 32388204)

1

1133

1133

... More
KIT Fuel Filter and Ring (CIL part no. KIT 3238493)

1

1601

1601

... More
KIT Super BYP Filter Elem (CIL part no. KIT 3879488)

1

2344

2344

... More
Inhibitor Corrosion (CIL part No. 3816986)

1

2660

2660

... More
ELEMENT,AIR CLEANER (3238665)

1

30725

30725

... More
Foil Sealed Test Strips (3403800)

1

436

436

... More
INDICATOR RESTRICTION (3872813)

1

876

876

... More
SEAL,O RING (3010937)

1

33

33

... More
Inhibitor Corrosion 10 liters(4926654)

5

5148

25740

... More
Radiwash 3 Ltr(AX1013359)

3

5142

15426

... More
Funnel Dual Filte Conduction -L(AX1015648)

1

19030

19030

... More
Premium Blue 7800 PLUS 1

10

762

7620

... More
B) Routine and Repair Maintenance Work Complete Checking and Calibration of following various type of safety relays installed in the HT panel with secondary injunction test set i/c Overhauling, Checking and Removal of minor defects and co-ordination of relay settings as reqd. 3.1 (a) IDMT relay (2 O/C, I E/F) UE

1

2150

2150

... More
Servicing of 11 KV 630 Amp, 350 MVA, 3 phase metal clad Vacuum Circuit Breaker complete with removal from the HT panel board, dismantling / opening the required parts for servicing, checking, cleaning, testing & rectification of defects, oiling, greasing, assembling i/c moisturization of bur bar & CTs with the help of suitable equipment etc. complete as required.

1

4473

4473

... More
Servicing of 430V 800/1000/1250 amps. 3 phase 50 Hz air circuit breaker i/c drawing out the ACB, cleaning of components, decarbonising of the arcing chamber, setting right the mechanism, lubricating the moving parts, checking & testing the continuity of control wiring, tightening of connections, measuring the insulation test resistance with LT insulation tester, measuring the contact resistance of moving & fixed contacts, replacement of minor worn out parts like nut bolts & spring washer etc., reinstallation, testing etc. complete as reqd.( Part / component required to be replaced shall be paid extra as per actual)

4

3034

12136

... More
Supply and replacement of following defective parts in the existing HT panel i/c control wiring thumbing , connection testing and commissioning and credit/buy back of old etc as required. A) LED Indicating light (Make : L&t)

1

163

163

... More
Complete Servicing of 1250 KVA, 11/0.415 KV 50 Hz dry type transformer complete with cleaning, checking of microprocessor based protection system, Hipot testing of HT winding and maggering of LT winding etc. as reqd. (for 1 year)

1

13606

13606

... More
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. A) 125 Amp, 16 KA, TPMCCB

1

4988

4988

... More
200 A, 25 KA, TPMCCB,

1

11397

11397

... More
250 Amp, 35 KA, TPMCCB

1

14361

14361

... More
400 Amp, 35 KA, TPMCCB

1

22333

22333

... More
Sub Head III : HVAC, STAC and WTAC Works A) Operation of 3 X 140 TR Capacity Centralized AC Plant and Hot Water Generator system Providing round the clock services for Operation of 3 X 140 TR Capacity Centralized AC Plant and Hot Water Generator system on the all days i/c Sunday & Holidays complete with cleaning & sweeping of A.C. Plant rooms and AHU's including maintaining record/register of temperaure for Mortuary Cold Rooms etc. complete as required i/c providing cleaning and sweeping material and uniforms etc. of deployed staff. a) A.C. Operator – 03 Nos. (01 No. in each shift for 3 shifts) b) Khallasi – 03 Nos. (01 No. in each shift for 3 shifts)- 01 Job i/c Sunday and Holiday as per terms and conditions attached.

3

215922

647766

... More
Annual Comprehensive Maintenance of the 3x140 TR Capacity Voltas Make AC Plant with all accessories and routine servicing, regular maintenance, preventive maintenance of equipments and components and break down repairs as and when occurred, ensuring that system does not remain out of service for a period more than one hours etc. as reqd. (The successful tendered shall keep the essential spares at site to avoid the delay in attending faults / maintenance)

3

114628

343884

... More
B) WTAC & STAC Works Providing day to day Maintenance & Repair of WTAC, Split A.C. Unit of 1.5TR / 2.0TR capacity and Water Coolers/Mortuary Cold Room installed at various locations of LBSH i/c Overhauling of machine attending complaint i/c checking & cleaning of condenser, Cooling coil with suitable chemical & all necessary preventive maintenance, as and when reqd. by providing experienced & qualified staff as per terms and condition attached & as per the direction of Engineer-in-Charge & site requirement. Following minimum staff shall be provided by the contractor excluding Sundays & holidays:- (1) AC Mechanic - 1 Nos. ( from 9 AM to 5 PM) (2) Khallasi - 2 Nos.( from 9 AM to 5 PM) (08 Month x 1Years i.e. March to October)

3

104473

313419

... More
C) Repairing /Servicing of HVAC/window/split AC Complete servicing of WTAC/STAC unit of 1.5 / 2.0 Tr capacity including dismantling the AC from its existing position i.e. various OPD's, Wards, ICU, OTs and various DA Dispensaries/Polyclinics etc, cleaning of evaporative and condensing coil with suitable chemical like coil cleaner, greasing of motor, cleaning of drain pipe and refining the same on its existing position complete etc. as required. (For One years) (319 Nos. Services in a year of each ACs)

30

400

12000

... More
Supplying & Charging of R-410a/R-22 refrigerant gas in existing following capacity WTAC / STAC unit i/c replacement of capillary tube & strainer, pressure testing, vaccumising, testing etc. complete as reqd. (For One years) A) In 2 TR capacity

10

3093

30930

... More
In 1.5 TR capacity

15

2390

35850

... More
Supplying & replacement of following capacity reciprocating/rotary type hermetically sealed compressor complete in the existing WTAC & STAC unit i/c repairing / rejoining of copper pipes, testing etc. & buy back the old etc. as reqd. A) 1.5 TR capacity

2

10924

21848

... More
2 TR capacity

1

13311

13311

... More
Supplying and replacement of PCB of remote control unit in the existing indoor unit of 2 TR/1.5TR Cap. STAC (Invertor Type)/WTAC of various makes i/c dismantling existing worn out PCB, connection, testing & buy back the old etc. as reqd. (as per sample)

6

3093

18558

... More
Supplying and replacement of outdoor unit of 1.5 TR capacity for existing split AC unit including connection with copper pipe, cables i/c buy back for credit of old units i/c testing and commssioning complete etc as requried.

1

19598

19598

... More
Supplying and replacement of indoor unit of 1.5 TR capacity for existing split AC units with remote i/c connection with copper pipe cablesi/c buy back for credit of old units i/c testing and commissioning complete etc as required.

1

10539

10539

... More
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : A) 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation

10

588

5880

... More
6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation

20

245

4900

... More
12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation

10

466

4660

... More
Sub Head - IV : Fire Fighting and Fire Alarm System A) Operation and Maintenance Fire Fighting and Wet Riser System: Providing services for running, operation & maintenance of Fire Fighting system at LBS Hospital in three shifts round the clock on all days i/c Sunday & holidays i/c weekly fire testing testing and maintaining the register, cleanness of equipments, installations & surroundings as per direction of Engineer-in-Charge and as per terms & conditions etc complete as required by providing the following staff:- (1) Operator cum wire man - 3 Nos. (1 in each shift)

3

118508

355524

... More
Fire Alarm System: Providing services for running, operation & maintenance of Fire Alarm system at LBS Hospital in three shifts round the clock on all days i/c Sunday & holidays i/c weekly fire testing testing and maintaining the register, cleanness of equipments, installations & surroundings as per direction of Engineer-in-Charge and as per terms & conditions etc complete as required by providing the following staff:- (1) Operator cum wire man - 3 Nos. (1 in each shift)

3

118508

355524

... More
B) Routine and Repair Maintenance Work Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required. A) 150mm dia

1

18401

18401

... More
100mm dia

1

11432

11432

... More
Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required. A) 10 zone panel.

1

16850

16850

... More
6 zone panel.

1

12599

12599

... More
4 zone panel.

1

9173

9173

... More
Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required.

1

203

203

... More
Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required.

6

1193

7158

... More
Supplying, installation, testing & commissioning of heat detector operating at 54ºC/57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required.

1

1108

1108

... More
Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in A.B.S. box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.

1

508

508

... More
Supplying, installation, testing & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.

1

422

422

... More
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.

13

179

2327

... More
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : a) Single headed Stainless steel

1

6351

6351

... More
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. a) 30 m

1

8975

8975

... More
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : a) Stainless Steel (Grade 304)

1

1719

1719

... More
Sub Head - V : EPBAX System Comprehensive maintenance & services of Electronic Private Automatic Exchange having 8 lines with all the standard features and maintenance of push button telephone intercom instruments upto 8 nos. i/c replacement of all spare parts/components as and when required ( At sub division office) - 1Job.

3

2047

6141

... More
Comprehensive maintenance & services of Electronic Private Automatic Exchange having 16 lines with all the standard features and maintenance of 10 no. push button telephone instruments i/c replacement of minor spare parts/components as and when required ( At Sub division office and Mayur Vihar Phase 1 ) - 2 Jobs.

3

5986

17958

... More
Sub Head - VI : Operation of Lift A) Operation Lift Providing services for running, operation & General maintenance of LBS Hospital in three shifts round the clock on all days i/c Sunday & holidays i/c cleanness of equipments, installations & surroundings as per direction of Engineer-in-Charge and as per terms & conditions etc complete as required by providing the following staff:- (1) Operator - 3 Nos. (1 in each shift)

3

118508

355524

... More
Comprehensive, maintenance of OTIS make hospital cum bed lift of capacity 20 person having speed of 0.5 mtr/sec installed at Lal Bahadur Shastri Hospital, Khichripur Delhi, Serving five floors (Ground + 4th Floor) as per terms & conditions attached - 1 job

3

19889

59667

... More
Sub Head - VII : LAN System and CCTV Cameras A) LAN System Comprehensive Maintenance of Juniper make Networking System & LAN System i/c all services, cleaning for checking repair & replacement of minor/major defective parts of with following scope of work: 1) Juniper Network Layer 3 10/100/1000-24 ports Giga Edge Switches 2 nos., 2) Juniper 10/100/1000-24 ports Giga Edge Switches 15 nos., 3) Fortigate Firewall system : 01 Nos 4) Cisco Network Router : 01 Nos 5) Poweride Network 9 U Racks,: 08 Nos 6) Poweride Network 32 U Rack: 01 Nos 7) D-link SFP Modules 25 Nos, 8)D-link Jack Panel 10 Nos, 9) D-link SM 6 port LIU : 06 Nos 10) D-link SM 12 port LIU : 04 Nos 11 D-link SM 24 Port LIU : 02 Nos 12) CAT-6 Low Smoke UTP cable: 8000 Mtrs 13) Schneider 6 core OFC cable : 650 Mtrs 14) D-link 1mtrs &2 Mtrs UTP Low Smoke Patch Cords : 345 Nos along with all accessories Excluded Plastic Trunking & Earthing Except Force Damage. -01 Job

3

61170

183510

... More
B) CCTV Cameras Comprehensive maintenance of CCTV system installted at LBHS Hospital , Khichripur , Delhi Having following accessories i. e. 1)Panasonic IP Based Bullet Camera : 28 Nos. 2) Panasonic IP Based Dome Camera: 45 Nos. 3) Panasonic IP Based PTZ Camera: 05 Nos. 4) Panasonic 64 Ch NVR system : 01 Nos 5) Panasonic 16 Ch NVR system : 1 No. 6) Work Station: 02 Nos. 7) 24 port Network Switch: 10 Nos. 8) 9 U Network Rack: 7 Nos. 9) LED Dispaly 32 Inches : 05 Nos. 10) Numeric 5KVA UPS : 01 Nos.

3

43836

131508

... More
Comprehensive maintenance of Panasonic make following CCTV accessories at LBHS Hospital, Khichripur, Delhi. 1) Panasonic IP Based Bullet Camera : 32 Nos. 2) Panasonic 16 Ch NVR system : 02 Nos 3) Work Station: 01 No. 4) 24 port Network Switch: 04 Nos. 5) 9 U Network Rack: 03 Nos. 6) Microteck 1 Kva UPS system : 10 Nos

3

92743

278229

... More
Providing round the clock services for CCTV Surveillance system complete with CCTV System , NVR system , LED Display, Network switches and other accessories intalled at LBHS Hospital , Khichripur , Delhi i/c Sunday & Holidays by deputing the following staff a) Operator - 3Nos (1 no.in each shift)

3

118508

355524

... More
Sub Head - VIII : AMC & Operation of 2X1000 LPH RO Plant and RO Inbuilt water cooler/ dispenser system A) AMC and Operaton Work of 2X1000 LPH RO Plant RO Inbuilt water cooler/ dispenser system Annual comprehensive maintenance contract of ICON Make RO plant 2x1000 LPH capacity installed at LBSH including all electrical and electronics spares i.e. starter, rotameter, MCB, pH meter, TDS meter, washing, rinsing of sand filter, rinsing of activated carbon filter, one time replacement of appropriate quantity of gravels & pebbles of all sizes, activated carbon, multiport valve, all pipe fittings, dosing pumps, electronic panels, TFC membranes, anti-scalent chemical and big blue micron filter, i/c overhauling of pump sets, replacement of bearing, replacement of water seals, gasket, replacement of damaged pipe lines and its accessories etc. as required to make RO plant to work smoothly and satisfactorily every month. (Consumable to be replace as and when required after expiry of the working life will be extra)

3

15877

47631

... More
Operating servicing etc. of moles system comprising of operating of the unit i.e. skilled operator for operating the R.O. units capacity -2X1000 LPH already installed at LBSH. The operator should be trained to operate RO Plant and backwash, Cleaning of Prefilter etc. in exiting plant, the work carried during 9:00 AM to 5:00 PM in Genral Shift excluding Sunday/Holiday etc. as reqd. at site.

3

34272

102816

... More
Annual Comprehensive Maintenanace of Water Cooler with inbuilt RO +UV of ATSIN Make with capacity 150 Ltr Storage Capacity and 150 ltr cooling capacity with 100 LPH RO System connected with water tank consisting of three mandatory Services, Repair/Replacement of all electrical and electronic spare parts like Speed Pump , Solenoid Valve, high pressure Switch, SMPS, adoptor and Attending complaints within 24 working hours with complete overhauling and servicing etc as reqd. (12 Nos For 24 Months)

36

5200

187200

... More
Annual Maintenance Contract of Hot , Cold & Normal Water Dispenser with inbuilt RO+UV with system Connected with storage tank consisting of three Mandatory Services, Repair/Replacement of all Electrical and Electronic Spare parts like Pump , SMPS, Adaptor , Solenoid Valve and High Pressure Switch and attending complaints within 24 working hours with complete overhauling and servicing etc as reqd (10 Nos For 24 Months)

30

1361

40830

... More
B) Repair/ Replacement & Major Maintenance Work Replacement of 4" X 40" RO Membrane (Make: Dow /CSM/ Hydronautics/Vontron/Filtek)

4

12650

50600

... More
Replacement of Big Blue Micro Filters of dia 20" X 4" up to filtration of 5 Micron (Make Chemflo /Hi-tech / Razor/Darlay/Icon)

12

689

8268

... More
Replacement of Micro Filters Bag of dia 20" X 4" up to filtration of 5 Micron

12

344

4128

... More
Antiscalent Chemical ( Make: Alkaline base)

60

362

21720

... More
Providing and arrangement of Treated Water Test Report from any DPCC authorized laboratory with following parameters to be tested. (After every six month) a) TSS b) BOD (Bio-Chemical Oxygen Demand) c) Oil and grease d) pH. e) Bio-Assay Test i/c Charges towards water input sample collection and got tested report etc. as required at site

1

9800

9800

... More
Supplying and Replacement of Following Spare/Components in the exisiting water Dispenser & Water Cooler with inbuilt RO+UV etc as reqd. (Make ATSIN) A) TFC Cartridge 1812 (For 10 Nos. dispenser X 2 Each in 4 Months)

15

4529

67935

... More
TFC Cartridge 4021 (For 12 Nos. RO+Water Cooler X 2 Each in 4 Months)

18

34701

624618

... More
Particulate Filter 20" (For 12 Nos. RO+Water Cooler X 2 Each in 4 Months)

18

1123

20214

... More
Activated Carbon 20" (For 12 Nos. RO+Water Cooler X 2 Each in 4 Months)

18

1241

22338

... More
Particulate Filter 10" (For 10 Nos. dispenser 1 each in 4 Months)

8

621

4968

... More
Activated Carbon 10" (For 10 Nos. dispenser 1 each in 4 Months)

8

646

5168

... More
Alkaline Filter (For 12 Nos. RO+Water Cooler X 1 Each in 4 Months)

9

4799

43191

... More
Alkaline Filter for dispenser (For 10 Nos. dispenser 1 each in 4 Months)

8

546

4368

... More
Supplying and Charging of R 134 Gas charging in the water Dispenser with inbuilt water purifier after pressure testing leak detection and rectified the breakage (if any) testing and commissioning etc as reqd.

1

2419

2419

... More
Supplying and Charging of R 134 Gas charging in the water Cooler for 150/150 with inbuilt water purifier after pressure testing leak detection and rectified the breakage(if any ) testing and commissioning etc as reqd.

2

5511

11022

... More
Sub Head - IX : Comprehensive Maintenance and Operation of mixed Oxidant Plant A) Comprehensive Maintenance and Operation of mixed Oxidant Plant Providing services of operation and routine maintenance of Aquapro make plant two sets of mixed oxidant based plants alongwith allied machinery and water filtration plant with high precision metering system installed in main park at LBS Hospital, Khichripur, Delhi the job shall be included as under: a) Round the clock operation with provide 1 No. operator cum mechanic in each shift. b) Charging of High grade reined industrial salt (30Kg/Plant per month). c) Charging of Orthophosphate based cleaning chemical for cell. (5 Ltr. Per month). d) Testing of chlorine estimation with test chemical.

3

129705

389115

... More
Supplying, cleaning of Regenerating chemical for Aquapro make water softening plant & its allied accessories at LBSH, which includes charging of water softening Plant with brine (Solution of common grade industrial salt) Qty: 60 Kg/Charging at periodic intervals i.e. 26 times a month to keep the output hardness of water within acceptable limits. The averaged requirement of charging shall be app. 26 per Month. It shall be within the scope of work to replace any component/ part/ chemical that may be the part of water softening system but not mentioned above. The Chemical to test the Raw water soft water before & after charging are including in the scope of work. (1560 Kg per Month)

3

24023

72069

... More
Supply and replacement of strongly Acidic Cationic Resin to the pressure vessel of softner for processing of water. AQUAPRO Make Capacity :20 Cu.m/Reg Quantity :400 Ltrs Make: Indion 220 Na/ Rohm Hass Or Equivalent

100

213

21300

... More
Sub Head - X :Various Delhi Govt Dispensary /Polyclinic A) Maintenance Work Providing services one shift from 9AM to 5 PM on all days except Sunday & holidays for day to day maintenance of electrical installation, street light, Panel and other electrical accessories at under mentioned buildings i/c cleanliness of equipments, installation & surroundings as per terms & condition as per the direction of Engineer-in-charge etc complete as required by providing following staff:- DGD Mayur Vihar Phase 1, DGD Trilokpuri, DGD Himmat Puri, DGD Kalyanpuri, DGD Mandawali, Polyclinic Vasundhara Enclave, Polyclinic Kondli, Polyclinic Kalyanvas, Polyclinic IP Extn, Veterinary Hospital Ghazipur, Delhi Staff Required: (1) Wireman - 1 No. (2) Khallasi - 1 No.

3

62451

187353

... More
Sub Head -XI : Supply of material A)Sub Station and DG Set Supply of 180 AH Battery for DG Sets, using existing man power for replacement on day to day maintenance work

1

15936

15936

... More
B) EI & FANS Supply of following material / accessories for using existing man power for replacement on day to day maintenance work: A) 5 Amp Piano type Switch

6

10

60

... More
5 Amp Piano type Socket

6

24

144

... More
15/16 Amp Piano type Switch

6

50

300

... More
15/16 Amp Piano type Socket

6

62

372

... More
5 Amp Modular Switch

44

35

1540

... More
5 Amp Modular Socket

25

65

1625

... More
15/16 Amp Modular Switch

44

77

3388

... More
15/16 Amp Modular Socket

38

109

4142

... More
6 to 32 Amp SP MCB

22

140

3080

... More
16 Amp DP MCB

13

452

5876

... More
32 Amp DP MCB

13

452

5876

... More
63 amp 4 pole Isolator

6

687

4122

... More
100 amp 4 pole Isolator

3

838

2514

... More
Modular switch type regulator stepped

6

228

1368

... More
100 A, 16 kA, TPMCCB

1

2735

2735

... More
Modular bell push, ISI marked

6

64

384



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.