Public Works Department Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Public Works Department - PWD Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date25 Dec 2024
Closing Date1 Jan 2025
Tender Amount₹ 11,01,100
Costs
EMD
₹ 22,022Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PWD_267224_1Tender No
89/EE(E)/South /Elect. Divn.,/PWD/2024-25Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://https://www.pwddelhi.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Replacement of 120Watt LED Flood light luminaire with secondary optics made in pressure die cast housing and heat sink in aluminum extrusion with IP66 i/c connection with all accessories i/c credit of old dismantle material etc. complete as required.
9
8547
76923
... More
S/I/T/C of weatherproof box made out of hot moulded SMC sheet with clamp, neutral link, strip, gland, thimble and 1 No. 10 Amps. SP MCB complete with inter connection, earthing etc as reqd.(Box Size: 300mm X 200mm X 105mm)
4
964
3856
... More
Supplying of following size multicore round Sheathed Bright Annealed Bare Copper Conductor Heavy Duty Industrial Cables for Voltage Grade RA upto 1100 Volts as per IS: 694:2010 etc. complete as reqd.
-
-
-
... More
3C X 1.5 Sq.mm.
120
137
16440
... More
3C X 2.5 Sq.mm.
100
181
18100
... More
3C X 4.0 Sq.mm.
120
199
23880
... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel / PVC conduit as required.
-
-
-
... More
3 X 1.5 sq.mm
440
95
41800
... More
3 X 2.5 sq.mm.
150
137
20550
... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
-
-
-
... More
15/16 A Switch
15
156
2340
... More
6 Pin 15/16 A Socket Outlet
15
197
2955
... More
15/16 Amp Plug top
15
256
3840
... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
... More
Single pole
15
256
3840
... More
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
... More
100 A
5
1227
6135
... More
Supplying and fixing suitable size PVC box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required.
60
722
43320
... More
Replacement, installation, testing and commissioning of 1200mm sweep ceiling fan with BEE rating of 2/3 star i/c the down road of standard length (upto 30cm) with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable i/c credit of old dismantle material etc. complete as required
5
3091
15455
... More
Replacement, installation, testing and commissioning of surface/wall mounted, not more than 18-20 Watt LED Batten with a system lumen output of 2200 lumens and a minimum system efficiency of 110 lumen/watt. The luminaire shall have a CRI of greater than or equal to 80. The luminaire is made of pre die cast housing and B17 input voltage range 140-270V, CCT-5700, P.F0.95, CRI 80, LED Service life 50000 operating hours at L70 i/c connection with 1.5 sq.mm copper conductor, single core cable and earthing i/c credit of old dismantle material etc. as required.
50
555
27750
... More
Replacement, installation, testing and commissioning of recess type 34W to 36W Full window glarefree opal Diffuser LED Panel of size 595X595mm suitable for Armstrong/POP/GB ceiling with MS Powder coated White Housing. Total system Lumen of 34W to 36W LED should be 3300 or above in Cool day Light(5600K to 6500K), Power factor0.90, CRI (Ra) 80, Complete with all accessories i/c credit of old dismantle material etc. complete as required
5
2618
13090
... More
Replacement, installation, testing and commissioning of surface type 34W to 36W Full window glarefree opal Diffuser LED Panel of size 595X595mm suitable for Armstrong/POP/GB ceiling with MS Powder coated White Housing. Total system Lumen of 34W to 36W LED should be 3300 or above in Cool day Light(5600K to 6500K), Power factor0.90, CRI (Ra) 80, Complete with all accessories i/c credit of old dismantle material etc. complete as required
10
3222
32220
... More
Replacement, installation, testing and commissioning of 15 Watt LED surface mounted round shaped LED downlighter with durable housing with al. heat sink with diffuser to give glare free light with removable driver i/c connection with all accessories i/c credit of old dismantle material etc. complete as required
12
1299
15588
... More
Replacement, installation, testing and commissioning of wall mounted cabin fan 450 mm sweep suitable for operating on 230 volt single phase AC supply i/c connection with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable earth i/c credit of old dismantle material etc. complete as required
4
6343
25372
... More
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A, 240 V “C” curve DP MCB complete with connections, testing and commissioning etc. as required.
30
1169
35070
... More
Replacement, installation, testing and commissioning of 900 rpm 450mm sweep exhaust fan metal body complete with louvers/shutters in the existing opening i/c making the hole to suit the size of the above fan making good the damage & connections i/c less credit of old dismental material as and where basis etc. as reqd.
3
7367
22101
... More
Supplying , Laying and fixing following size of PVC insulated and PVC sheathed al. conductor armoured power cable of 1.1 KV grade of following ways as reqd.
-
-
-
... More
(a) 4 X 16 sq.mm. cable on surface
50
403
20150
... More
(b) 4 X 25 sq.mm. cable on surface
40
494
19760
... More
(c) 4 X 25 sq.mm. cable on surface
40
645
25800
... More
(d) 3.5 X 85 sq.mm. cable on surface
50
2443
122150
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
-
-
-
... More
4 X 16 sq. mm (28mm)
4
309
1236
... More
4 X 25 sq. mm (28mm)
2
315
630
... More
4 X 35 sq. mm (32mm)
2
370
740
... More
3.5 X 185 sq.mm (57mm)
2
875
1750
... More
Supply & Fixing of 50 X 80 mm PVC snap on trunking i/c body and cover including joint accessories like bend etc. on surface of wall etc. complete as required
90
1854
166860
... More
Routine maintenance of WTAC / STAC/Water Cooler/Tower AC of (1.5/2.0) Ton AC of Different makes installed at DSEU Sirifort Campus i/c attending day to day complaints on alternate days from 9:30 AM to 5:30 PM and checking of starting capacitor, running capacitor, PCB Cards and leakage etc. complete as required. - 10 Nos.
1
18721
18721
... More
Servicing & overhauling of following all type of Split / WTAC unit as well as cooling coil with sulphonic chemical & high pressure water, oiling / greasing of blower & condenser motor, checking & tightening of elect. connection, replacement of defective spare parts (if any) including dismantling & reinstallation at the existing location after servicing, testing & commissioning etc. as reqd.
-
-
-
... More
(i) 1.5/2.0 TR WTAC
4
596
2384
... More
(ii) 5.5/8.5 TR Ductable Split AC
2
5668
11336
... More
Supplying & fixing following size copper pipe/ valve brazing/ welding & leakage testing in 1.5/ 2TR split AC unit i/c insulation cover of copper pipe, testing, commissioning complete etc as reqd.(i/c rebate for dismantle material if any).
-
-
-
... More
6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
6
245
1470
... More
22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
4
865
3460
... More
Supplying, filling/charging R-22 refrigerant gas & pressure testing of refrigerant circuit with nitrogen gas i/c repair/ welding etc complete as reqd of the following capacity of WT/split/ cassette type AC.
-
-
-
... More
1.5/2.0 TR WTAC/Split AC
4
2446
9784
... More
5.5 TR Ductable Split AC
2
9244
18488
... More
8.5 TR Ductable Split AC
1
11018
11018
... More
Replacement of old burnt/ defective compressor from window/ split type AC units with supply & installation of new compressor i/c cutting/ welding the copper piping & rebate/buyback old dismantled compressor etc complete as reqd.
-
-
-
... More
1.5TR compressor
1
10143
10143
... More
Running Capacitor 36mfd Casing - Aluminum / Terminal - Copper Wire
1
268
268
... More
Running Capacitor 45mfd Casing - Aluminum / Terminal - Copper Wire
1
348
348
... More
Blower Motor 62W (1/12 HP)
1
3835
3835
... More
PCB
1
2444
2444
... More
Replacement of worn out / defective copper condenser coil with new one of the same size and design suitable for 1.5/2.0 TR Split type AC Out Door unit i/c breezing the all copper pipe with all distribution joint’s, and make sure the connections with capillary tube etc. Pressure testing, leak detection, vaccumizing the unit, gas charging i/c credit of old dismantle material as and where basis etc, complete as reqd
2
6680
13360
... More
Replacement of following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections i/c credit of old dismantle material etc. as required
-
-
-
... More
400 A, 35 kA,TPMCCB
1
21186
21186
... More
125 A, 16 kA,TPMCCB
2
4696
9392
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements