Public Works Department Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Public Works Department - PWD Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date12 Sep 2024
Closing Date20 Sep 2024
Tender Amount₹ 9,51,384
Costs
EMD
₹ 19,028Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Rmo Ei And Fans And All Various Electrical And Mechanical Services Installed At District Court Complex, Saket, New Delhi. 110017 (sh Miscellaneous Ei Work In Court Complex As And When Required)
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PWD_262265_1Bid Award Id
ViewTender No
173/EE(E)/JED-1/PWD/2024-25Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://https://www.pwddelhi.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
40 A
5
4850
970
... More
63 A
5
5170
1034
... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
... More
25 A
5
10140
2028
... More
40 A
5
13210
2642
... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
... More
25 A
10
25860
2586
... More
40A
10
31880
3188
... More
63 A
10
28720
2872
... More
SITC of Heavy duty exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required on site. A) 250 mm sweep
20
95880
4794
... More
Supplying and fixing following rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required including buyback/less credit of dismantled material if any received from site.
-
-
-
... More
a) 40 A TPN MCB
10
24110
2411
... More
b) 63 A TPN MCB
10
25060
2506
... More
Supplying and replacement, installation, testing and commissioning of surface mounted type Downlighter luminaire of 12-15 W, (5700K having powder coated CRCA housing making connections with 1.5sq.mm. PVC insulated FRLS, copper conductor, single core cable including loop earthing with 1.5 sq.mm FRLS PVC insulated copper conductor, single core cable complete etc. as required, complete with all accessories/ attachments etc as requirement of site and compatible with the existing false ceiling cutting, including buyback/less credit of dismantled material if any received from site.
10
7830
783
... More
SITC of storage water cooler cum purifier with 80 Litre storage and 60 Litre cooling capacity with inbuilt 7 stage Ultra Violet based Purification system, operates on 220V ±10% V AC, 50 Hz with power consumption 650 watt ±10% Providing water oulet temperature at 17˚C at 1 Degree C inlet and outer body dimension min. 670x482x1470 mm or as per direction of Engineer in Charge with PUF thermal insulation compressor make should be of Kirloskar/Emerson/Tecumseh and Refrigerant should be of R134A (Eco Friendly). The storage tank and outer body material should be of SS304 only.
2
266024
133012
... More
Less for credit buy back of rusted/rotten/burnt out/non working accessories
-
-
-
... More
Four pole isolator 40A/63 A
5
-150
-30
... More
Double pole, (single phase and neutral), 240 V, (RCCB), 25A/40A
10
-400
-40
... More
Four pole, (three phase and neutral), 415 V, (RCCB), 24/40/63 A
10
-500
-50