Public Works Department Tender

If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Public Works Department - PWD Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date6 Dec 2024
Closing Date13 Dec 2024
Tender Amount₹ 73,68,397 
Notes
Download

Costs

Summary

R.m.o E And M Services At Rcl Office, Tcpc(o), Tcpc (l) Sunder Nagari, A. Gram, K. Gram, G. Gram Leprosy Complex, Hltb/hlab Jail Block, Tahir Pur, Sanskar Ashram Dilshad Garden, Sd M-2222, Civil Sd M-2114, Tahirpur Red Light Delhi And M-2221

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
RCL office, TCPC(O), TCPC (L) Sunder Nagari, Civil Sub Division M-2222, Civil Sub Division M-2114, Tahirpur Red Light & M- 2221 Running operation and routine maintenance of internal EI & light points, fan points, Exhaust Fan point, call bell point i/c power point and main distribution board and SDB’s, pump sets and control panel cleaning of all electrical installation at RCL office, TCPC(O), TCPC (L) sunder nagari, Civil Sub Division M-2222, Civil Sub Division M-2114, Tahirpur Red Light in General shift 9:00 AM to 5:00 PM on all days of week excluding Sunday & holidays. a) 1 Nos. Wireman cum Operator (9.00 AM to 5.00PM) b) 1 Nos. Khallasi (9.00 AM to 5.00PM) - 1 Job

12

55907

670884

... More
Replacement of defective fitting by Supplying, Installation, Testing & Commissioning 18 to 20 watt 1200 mm long high efficiency LED linear batten Luminaries having aluminium extruded housing and polycarbonate diffuser within built APFC driver having efficiency of driver 85% power factor 0.90, THD 20% with minimum 2.5 KV surge protection, LED life with L-70 criteria shall be not less than 50000 burning hours etc. suitable for operation on 150 to 265V single phase A.C. supply, having system efficiency 120 luman per watt and colour temperature of 6000 K, CRI 80 including connect ion with 1 5 sq. mm PVC insulated copper conductor FRLS cable i/c dismantling of existing old fitting if any etc. complete as required.

160

760

121600

... More
Replacement of defective flood light by Supplying and Fixing 70-80 Watt 5700 K 300 X 150 LED flood light fittings suitable for operation on 220 Volt 50 Hz AC supply i/c Providing & Fixing suitable clamp, nut bolts, connectors, earthing the body (Dismantling of existing, if any) complete etc. as reqd.

12

8264

99168

... More
Replacement of defective by S.I.T.C. of electric ceiling fans 1200mm sweep shall be capacitor type, with double ball bearing complete with capacitor, 300mm down rods, canopies, three number blades made of aluminum alloy, suitable for operation on single phase, AC 230 volt, 50Hz supply and but without regulator.

80

2191

175280

... More
Supplying and Installation of exhaust fan upto 380mm sweep 900 RPM in the existing opening, including making the hole to suit the size of the above fan, i/c louvers, making good the damage, connection, testing, commissioning etc. as required.

50

4213

210650

... More
Supplying Installation, testing & commissioning of wall fan 400 mm sweep in the existing surface and making good the damage, making connections, interconnections, earthing etc. as required.

12

2814

33768

... More
Supplying and Fixing of Ventilating Exhaust fan upto 250mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning etc. as required.

10

1861

18610

... More
Servicing/overhauling the desert/room coolers, checking the unit, changing the wood wool pads, distributor of water, elbow, PVC pipe of required length, Balde, oiling of Blower motor, fixing missing nuts, bolts, screws etc. providing necessary insulation tape etc. on wire joints, reinstallation of Desert Coolers to its original position, testing, commissioning etc. complete as required.

101

840

84840

... More
Supply & Replacement of Cooler Pump in the existing Desert Cooler etc. complete as required.

65

270

17550

... More
Supply & Replacement of burnt out Cooler Motor single phase motor in existing desert coolers i/c testing commissioning etc. as required.

40

2490

99600

... More
Servicing of 25Ltr. water heater (Geyser) by chemical and remove the waste powder from tank i/c remove from the site and reinstall testing commissioning etc. as required.

50

1341

67050

... More
Repairing of 25Ltr. water heater (Geyser) by replacing of following defective parts and buy back of dismentle material i/c testing commissioning etc. as required. (a) Thermostate

25

598

14950

... More
(b) Element

20

1771

35420

... More
Supply and replacement of defective Geyser Connection pipe SS body of 60 inch i/c connection testing etc. as required.

20

821

16420

... More
Taking out submersible /mono submersible p/set upto 15 HP rating along with G.I Pipe from existing bore well/ sump with the help of chain and pulley block etc. as reqd. i/c cartage from site to workshop as required.

16

2952

47232

... More
Lowering of submersible /mono submersible pump set upto 15 Hp rating along with G.I Pipe from existing bore well/ sump with the help of chain and pulley block i/c cartage from workshop to site etc. as required.

16

2952

47232

... More
Supplying & Fixing of 1 HP Monoblock Pump 25x25 mm i/c testing commissioning etc. complete as required.

2

12855

25710

... More
Replacement of defective by S.I.T.C of 3 HP, submersible pump set 10 stage, outlet size 50mm, directly coupled with submersible electric motor suitable for 220 volt ± 10% Single phase, 50 HZ Ac supply, with chain pully block and tripot stand taking out the existing pump and lowing new pump complete etc. as reqd

1

31467

31467

... More
Replacement of defective by S.I.T.C of 5 HP, submersible pump set 18 stage, outlet size 50mm, directly coupled with submersible electric motor suitable for 420 volt ± 10% Three phase, 50 HZ Ac supply, with chain pully block and tripot stand taking out the existing pump and lowing new pump complete etc. as reqd.

1

46748

46748

... More
Replacement of defective by S.I.T.C of 5 HP, Submersible openwell Monoblock pump set, Suc Del. Size 65mmX50mm electric motor suitable for 420 volt, Three phase, 50 HZ Ac supply, with chain pully block and tripot stand etc. complete as reqd.

1

40615

40615

... More
Replacement of defective by S.I.T.C of 7.5 HP, Submersible Monoblock pump set, Suc Del. Size 65mmX50mm electric motor suitable for 420 volt, Three phase, 50 HZ Ac supply, with chain pully block and tripot stand etc. complete as reqd.

1

54117

54117

... More
Replacement of defective by Supplying and fixing 3x4 sq.mm copper conductor flat submersible cable along with pump / in Pipe /on surface as reqd.

190

245

46550

... More
Replacement of defective by Supplying and fixing 3x10 sq.mm copper conductor flat submersible cable along with pump / in Pipe /on surface as reqd.

120

543

65160

... More
Repairing overhauling & Rewinding of 5 HP submersible pump set i/c replacement of emplier, replacement of all burnt parts i.e. G.M. Bush, Thrust Plate, Motor Seal 2 nos O-Ring, Ss Stad, ss key 1 No. gasket 1set,ballbering 2nos, 6305, etc. i/c reassembling testing, commissioning etc. complete as reqd.

2

10517

21034

... More
Repairing overhauling & Rewinding of 10 HP Sewage pump set i/c replacement of emplier, replacement of all burnt parts i.e. G.M. Bush, Thrust Plate, Motor Seal 2 nos O-Ring, Ss Stad, ss key 1 No. gasket 1set,ballbering 2nos, 6305, etc. i/c reassembling testing, commissioning etc. complete as reqd.

3

16282

48846

... More
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. GROUP C

90

894

80460

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.

-

-

-

... More
3 x 1.5 sq. mm

180

95

17100

... More
6 x 1.5 sq. mm

60

181

10860

... More
3 x 4 sq. mm

250

206

51500

... More
6 x 4 sq. mm

80

396

31680

... More
Supplying and fixing of following sizes of PVC conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

... More
a) 20 mm

90

128

11520

... More
b) 25 mm

50

145

7250

... More
Replacement of defective by Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)

-

-

-

... More
6 way, Double door

5

2206

11030

... More
8 way, Double door

3

2573

7719

... More
12 way, Double door

1

2315

2315

... More
Replacement of defective by Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 125 A, 16 kA, TPMCCB

4

4821

19284

... More
Replacement of defective by Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)

-

-

-

... More
8 way (4 + 24), Double door

2

10165

20330

... More
12 way (4 + 36), Double door

2

12833

25666

... More
Replacement of defective by Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole

220

256

56320

... More
Single pole and neutral

10

599

5990

... More
Replacement of defective by Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A

15

1034

15510

20

1227

24540

... More
Replacement of defective box by Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess i/c dismentling the existing etc. as required

-

-

-

... More
3 Module (100 mmX75 mm)

50

327

16350

... More
6 Module (200 mmX75 mm)

15

402

6030

... More
12 Module (200 mmX150 mm)

30

547

16410

... More
Replacement of defective Switch/socket by Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.

-

-

-

... More
5/6 A switch

190

103

19570

... More
3 pin 5/6 A socket outlet

35

122

4270

... More
15/16 A switch

200

156

31200

... More
6 pin 15/16 amp socket outlet

200

197

39400

... More
Less on buy back assorted Material

-

-

-

... More
Assorted Ceiling Fan/Exhaust Fan

100

300

-30000

... More
Assorted i.e. Wire, Switch socket, XLPE Cable, MCB, DB, MCCB, Submersible Cable, TPDB etc.

1

20000

-20000

... More
Assorted Flood Light

10

200

-2000

... More
Assorted LED fitting Batten

100

30

-3000

... More
Assorted Wall Fan/Ventilation Fan

20

200

-4000

... More
Assorted Cooler Pump

50

20

-1000

... More
Assorted Cooler Motor

30

150

-4500

... More
Assorted Thermostate/Element

30

200

-6000

... More
Assorted 1HP Motor

2

1000

-2000

... More
Assorted 5HP/7.5 Submersible Pump

2

3000

-6000

... More
Assorted 5HP/7.5 Mono Submersible Pump

2

3000

-6000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.