Public Works Department Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Public Works Department - PWD Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date6 Nov 2024
Closing Date14 Nov 2024
Tender Amount₹ 6,51,591
Costs
EMD
₹ 13,032Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
1. Providing Electrical Work, Wiring, Led Lights, Ceiling Fan And Other Electrical Work At Pwd Building, C-block Icds, Paschim Vihar, Ssk-224, New Delhi. 2. Providing Electrical Work, Wiring Of Light Points, Etc (full Name Of Work Mentioned In Nit)
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PWD_264527_1Bid Award Id
ViewTender No
34/EE(E)/West Elect Div(M-131N)/PWD/2024-25Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://https://www.pwddelhi.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
2 X 1.5sq. mm + 1 X 1.5 sq. mm earth wire
50
241
12050
2 X4 sq. mm + 1 X 4 sq. mm earth wire
95
346
32870
4 X4 sq. mm + 2 X 4 sq. mm earth wire
80
556
44480
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
-
-
-
3x1.5sq. mm
20
98
1960
3x4sq.mm
20
213
4260
6 x 1.5 sq. mm
40
187
7480
6x4sq.mm
20
410
8200
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
-
-
-
15/16 A switch
14
161
2254
6 pin 15/16 A socket outlet
14
204
2856
Supplying and fixing following size/ modules, Gl box alongwith modular base & cover plate for modular switches in recess etc. as required.
-
-
-
6 Module (200mmX75mm)
3
416
1248
12 Module (200mmX150mm)
2
566
1132
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required
10
606
6060
Supplying & fixing suitable size Gl box wih modular plate and cover in fronton surface or inrecess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
1
752
752
Supplying, Installation, Testing & Commissioning of 32-36Watt 2x2 feet LED light luminaires suitable for recessed armstrong/grid ceiling pre-wired, aluminium body having 100 Lumen per watt, CCT 5700K to 6500K, power factor0.90, CRI 70% (including dismantiling the old fitting if any where ever required) complete with all accessories etc. directly on ceiling/wall including connections with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc as required and as per additional specification for LED attached.
(LED panel is to be hinged with chain and tied with the ceiling with suitable arrangment)
12
3660
43920
Supply, installation, testing and commissioning of 4.1 Litres 3 Taps for hot, cold and normal water Top Load Water Dispenser suitable for operation on 230 volts ±10% complete etc. as reqd.
1
7825
7825
Supply, installation, testing and commissioning of Split AC of 2/2.2 TR capacity inverter type complete with indoor and outdoor units with rotary compressor, 3 star BEE rating, copper condenser with remote hand set with 3 mtr.copper piping, flexible copper wire and drain pipe suitable for operation on 230 volts ±10% complete etc. as reqd.
1
63457
63457
SITC of 5 KVA capacity Automatic Line Voltage
stablizer copper bound wall mounted having following specifiation with TDR. :-
(a) Input Voltage : 170-275 volt
(b) Output Voltage : 230 volts (+ 10%)
1
3843
3843
Providing extra refrigerant piping complete with copper pipe of size 1/2 & 3/8 with tube insulation and 3 core wire of suitable size 70/.076 complete etc. as required.
6
518
3108
Providing and fixing of readymade MS fabricated and duly painted, wall bracket type stands for mounting the Split A.C. outdoor unit including grouting on the wall and making good the damages to surface complete with rubber vibration pads on outdoor unit bolts etc. complete as required
1
792
792
Supplying, Installation testing and commissioning of 1200mm sweep ceiling fan capacitor type with double ball bearing suitable for operation of single phase AC supply with maximum power consumption of 50W capable to deliver 210m³/min. speed of 320rpm (min.) including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FRLS insulated, copper conductor, single core cable etc as required.
4
1990
7960
Supplying, Installation, Testing and Commissioning of 300 mm Sweep heavy duty exhaust fan of 900 RPM single phase including louvers and shutter, fixing with suitable arrangement, connection with 1.5 sq.mm. FRLS PVC insulated wire complete etc. as reqd
4
2120
8480
Supplying, Installation, testing and commessioning of pre-wired, aluminium extruded LED batten of 40W with a min system efficacy 110 lumen/Watt , CCT 5700K to 6500K, power factor0.90, CRI70% (including dismantling the old fitting if any where ever required) complete with all accessories etc. directly on ceiling/wall including connections with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc as requied.
16
1098
17568
SITC of 70 watt LED street light of CCT (K) 5700 having Aliminimum Die-cast housing luminaire for enhanced uniform illumination and toughened glass with silicon gasket for IP66 protection i/c connection & dismantling the existing fitting etc as reqd.
2
4636
9272
SITC of 1 HP Mono Block pump with pipe size 25 X 25 mm, head range 6-45 mtr and discharge range 2800-880 LPH suitable for working on single phase, 50 Hz AC supply as required.
1
7650
7650
Supply & fixing of 6 kg ABC type Fire Extinguisher Stored pressure type wall mounted duly ISI marked conforming to IS:14609 ISI complete with squeeze grip release valve, locking arrangement, pressure gauge, discharged pipe and operation manual etc complete as required.
1
4535
4535
Supply & fixing of 4.5 kg CO2 type Fire Extinguisher Stored pressure type wall mounted duly ISI marked conforming to IS:15683 ISI complete with squeeze grip release valve, locking arrangement, pressure gauge, discharged pipe and operation manual etc complete as required.
1
9070
9070
Sub Head- II:- Providing Electrical Work, Wiring of Light points, Fan points, Fan, LED Light, Security Light, Motor at ICDS, Vishnu Garden Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
-
-
-
Group C
20
1886
37720
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
-
-
-
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
20
338
6760
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
25
443
11075
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
15
609
9135
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required
6
606
3636
Supplying, Installation, testing and commissioning of pre-wired 100 Watt flood light LED luminaire made out of PDC aluminium body with minimum lumens 110 per watt suitable for cool day white light having minimum CCT 6500K, power factor not less than 0.90, CRI 70% (including dismantling the old fitting if any) complete with all accessories etc. directly on wall/pole/mast mast including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. as per additional specification for LED attached with connections.
4
3904
15616
Supplying & fixing wall mounted 2 pole PVC MCB box having weather proof IP 65 rated with front openable hinged type cover with locking arrangement i/c etc. as required.
4
487
1948
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator)
-
-
-
12 way , Double door
1
2395
2395
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
Single pole
10
265
2650
Single pole and neutral
1
620
620
Supplying, Installation testing and commissioning of 1200mm sweep ceiling fan capacitor type with double ball bearing suitable for operation of single phase AC supply with maximum power consumption of 50W capable to deliver 210m³/min. speed of 320rpm (min.) including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FRLS insulated, copper conductor, single core cable etc as required.
4
1990
7960
Supplying, Installation, testing and commessioning of pre-wired, aluminium extruded LED batten of 40W with a min system efficacy 110 lumen/Watt , CCT 5700K to 6500K, power factor0.90, CRI70% (including dismantling the old fitting if any where ever required) complete with all accessories etc. directly on ceiling/wall including connections with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc as requied.
12
1098
13176
Supplying, Installation, Testing and Commissioning of 400 mm Sweep, minimum 1300rpm with maximum power consumption of 50W wall mounting wall fan including fixing with dash fastener, connection with 1.5 sq.mm. FRLS PVC insulated wire complete etc. as reqd.
5
2288
11440
Supplying & laying of 3 x 10 Sq.mm XLPE insulated and PVC sheathed Aluminium conductor armoured power cable of 1.1 KV grade conf. to IS 7098 (Part-I) on surface with the help on suitable clamp etc. as required.
50
301
15050
Supplying, Installation, Testing and Commissioning of 300 mm Sweep fresh air exhaut fan minimum 1300rpm with maximum power consumption of 70W including louvers and shutter, fixing with suitable arrangement, connection with 1.5 sq.mm. FRLS PVC insulated wire complete etc. as reqd
1
2120
2120
SITC of 1 HP Mono Block pump with pipe size 25 X 25 mm, head range 6-45 mtr and discharge range 2800-880 LPH suitable for working on single phase, 50 Hz AC supply as required.
1
7650
7650
Supply & fixing of 6 kg ABC type Fire Extinguisher Stored pressure type wall mounted duly ISI marked conforming to IS:14609 ISI complete with squeeze grip release valve, locking arrangement, pressure gauge, discharged pipe and operation manual etc complete as required.
1
4490
4490
Supply & fixing of 4.5 kg CO2 type Fire Extinguisher Stored pressure type wall mounted duly ISI marked conforming to IS:15683 ISI complete with squeeze grip release valve, locking arrangement, pressure gauge, discharged pipe and operation manual etc complete as required.
1
8980
8980
Evaluation Notes How It Works ?