Public Works Department Tender
... More
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Public Works Department - PWD Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date14 Feb 2025
Closing Date21 Feb 2025
Tender Amount₹ 26,77,692
Costs
EMD
₹ 53,554Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_PWD_268491_1Bid Award Id
ViewTender No
82/2024-25/EMD M-351/EE(E)Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://https://www.pwddelhi.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
-
-
-
... More
3 Module (100 mmX75 mm)
40
327
13080
... More
6 Module (200mmX75mm)
25
402
10050
... More
8 Module (125 mmX125 mm)
15
454
6810
... More
12 Module (200mmX150mm)
10
547
5470
... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
-
-
-
... More
3 X 1.5 mm
400
95
38000
... More
3 x 4 sq. mm
250
206
51500
... More
3 x 6 sq. mm
150
304
45600
... More
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit
as required. a) 25 mm
100
256
25600
... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) i) 8 way double door
4
2573
10292
... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. A) Single pole
30
256
7680
... More
Single pole and neutral
5
599
2995
... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator). a) 8 way (4 + 24), Double door
2
5967
11934
... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.a) 5/6 amps switch
50
103
5150
... More
15/16 A switch
25
156
3900
... More
3 pin 5/6 A socket outlet
20
122
2440
... More
6 pin 15/16 A socket outlet
10
197
1970
... More
Telephone socket outlet
10
148
1480
... More
Bell push
15
140
2100
... More
Supplying, Installation, Testing & Commissioning of SMC pole Box of size 250mm x 200mm x 105mm with hinged cover on surface/ recess/pole complete with aluminium connector strip - 2 Nos, MS Clamp - 2 Nos., 6-32amp. C series SPMCB- 1 No., having IP: 66 protection connection etc. as reqd.
10
1751
17510
... More
S.I.T.C of following 35 watt LED Post Top Lantern fitting made out of CRCA sheet, duly powder coated /Aluminium body, confirming to IP - 66, suitable for operation on 150 V to 270 V,(5500 to 6500K), 50 Hz AC Supply, having power factor ≥ 0.95, CRI 80, Luminaries efficacy ≥ 80 lumen/watt , Driver efficiency 85%, 10 kv surge protection, L-70 Life 50,000 burning hours. complete i/c dismentaling of existing fitting if any, connection, etc complete as reqd. (Note:- Contractor shall submit 5 Years gurantee certificate of respective manufacturer along with the fitting).
10
7649
76490
... More
Supplying, installation, Testing & Commissioning of 36 watt Surface / recessed Panel Down light 2x2 ft., powder coated die cast aluminium/polycarbonate body with built in driver (750ma), Operating voltage AC 100- 240 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD 10% , P. F.≥0.95, IP20, CRI 80, life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard (As mentioned in Bottom Note)and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted,Minimum 5 year OEM warranty, . Shape size and CCT shall be as approved by Engineer in charge. System lumen efficacy ≥105 and 120 lm/Watt output All as per pre approved by Engineer-in-charge.
15
3567
53505
... More
Supplying, installation, Testing & Commissioning of 18-20watt (1200 mm 4 Feet)LED surface mounted Batten light, powder coated die cast aluminium /polycarbonate body with built in driver ( 750ma),Operating voltage AC 100-240 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD 10% , P. F.≥0.95, IP20, CRI 80 , life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard (As mentioned in Bottom Note)and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. "complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required" , (LM79 & LM80) certificate / Report from OEM shall be submitted. Minimum 5 year OEM warranty, . Shape size and CCT shall be as approved by Engineer in charge. System lumen efficacy system lumen efficacy ≥105 and 120 lm/Watt output. All as per pre approved by Engineer-in-charge
50
1418
70900
... More
Supply, Installation, Testing and Commissioning of BEE rated, ceiling fan with squirrel cage induction Motor, class of insulation: B, 3 nos. metal( Aliminium alloy blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body, Power Factor not less than 0.9 , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit of suitable wattage for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as reqd.
1) 1200mm, BEE 3 star rating, service value ≥5.0 to 5.5 CM/Min/Watt, air delivery 210 CM/Min ( Minimum)
25
2669
66725
... More
Supplying, Installation, Testing and Commissioning of 300 mm Sweep 900 RPM Heavy Duty ISI Marked Exhaust fan with louvers & shutters in the existing opening, including making good the same, connection, testing, commissioning etc. as reqd.
5
3835
19175
... More
Supplying laying and fixing of one number PVC insulated and PVC sheathed / XLPE aluminium power cable of 1.1 kV grade of following size on existing DWC Pipe etc as required.
-
-
-
... More
3 x 10 sqmm
150
285
42750