If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Public Works Department - PWD Tender

Services
Machinery and Tools
Electrical and Electronics
Electrical Works
Eprocure
Opening Date24 Dec 2024
Closing Soon31 Dec 2024
Tender Amount₹ 63,83,143 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
1.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable

600

18

10800

... More
4.0 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable

600

42

25200

... More
6.0 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable

150

63

9450

... More
10 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable

70

106

7420

... More
3 pin 5/6 A modular socket outlet, ISI marked

200

63

12600

... More
6 pin 15/16 A modular socket outlet, ISI marked

200

105

21000

... More
S.P. 5/6 A, one way modular switch, ISI marked

200

34

6800

... More
S.P. 15/16 A, one way modular switch, ISI marked

200

74

14800

... More
Modular base & cover plate for 3 module

70

56

3920

... More
Modular base & cover plate for 6 module

150

79

11850

... More
Modular base & cover plate for 8 module

50

101

5050

... More
Stepped type Modular Fan regulator (2 module)

100

220

22000

... More
Modular base & cover plate for 12 module

50

147

7350

... More
25 A modular socket outlet and 25 A modular SP MCB, “C” curve

50

161

8050

... More
Supplying, Installation, Testing and Commissioning of 150 mm sweep fresh air fan working on 230 +/- 10 V single phase 50 Hz Frequency complete with shutter in existing hole of suitable size making good the same i/c connections, interconnections etc. complete as reqd.

50

1309

65450

... More
Supplying, Installation, Testing and Commissioning of 200 mm sweep fresh air fan working on 230 +/- 10 V single phase 50 Hz Frequency complete with shutter in existing hole of suitable size making good the same i/c connections, interconnections etc. complete as reqd.

30

1461

43830

... More
Supplying, Installation, Testing and Commissioning of 250 mm sweep fresh air fan working on 230 +/- 10 V single phase 50 Hz Frequency complete with shutter in existing hole of suitable size making good the same i/c connections, interconnections etc. complete as reqd.

30

1535

46050

... More
Supplying, Installation, Testing and Commissioning of 300 mm Sweep 900 RPM Heavy Duty ISI Marked Exhaust fan with louvers & shutters in the existing opening, including making good the same, connection, testing, commissioning etc. as reqd.

45

3835

172575

... More
Supplying, Installation, Testing and Commissioning of 400 mm Sweep wall Fan suitable for 230 V 50 Hz Ac Supply complete with all accessories on existing wall etc. complete as required.

50

2472

123600

... More
Supply, Installation, Testing and Commissioning of BEE rated, ceiling fan with squirrel cage induction Motor, class of insulation: B, 3 nos. metal( Aliminium alloy blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body, Power Factor not less than 0.9 , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit of suitable wattage for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as reqd.

-

-

-

... More
1200mm, BEE 3 star rating, service value ≥5.0 to 5.5 CM/Min/Watt, air delivery 210 CM/Min ( Minimum)

40

2669

106760

... More
1400mm, BEE, service value ≥5.0 to 5.5 CM/Min/Watt, air delivery 210 CM/Min ( Minimum)

20

2567

51340

... More
S.I.T.C of 6-10 W LED bulkhead fitting made out of CRCA sheet duly power coated/Cast Aluminium body, confirming to IP66, suitable for operation on 240 V, 50 Hz AC Supply having power factor ≥ 0.90, complete i/c making connection, testing and comissioining etc complete as reqd. (Note:- Contractor shall submit 5 Years gurantee certificate of respective manufacturer along with the fitting).

40

1523

60920

... More
Supplying, installation, Testing & Commissioning of LED surface mounted Batten light, powder coated die cast aluminium /polycarbonate body with built in driver ( 750ma),Operating voltage AC 100-240 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD 10% , P. F.≥0.95, IP20, CRI 80 , life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard (As mentioned in Bottom Note)and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. "complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required" , (LM79 & LM80) certificate / Report from OEM shall be submitted. Minimum 5 year OEM warranty, . Shape size and CCT shall be as approved by Engineer in charge. System lumen efficacy system lumen efficacy ≥105 and 120 lm/Watt output. All as per pre approved by Engineer-in-charge

-

-

-

... More
18-20watt (600 mm 2 Feet)

40

917

36680

... More
Supplying, installation, Testing & Commissioning of LED Recessed/surface Panel Down lighter (Round / square/ Rectangular, powder coated die cast aluminium/polycarbonate body with built in driver ( 750ma), Operating voltage AC 100-240 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD 10% , P. F.≥0.95, IP20, CRI 80 , life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard (As mentioned in Bottom Note)and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. "complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required" , (LM79 & LM80) certificate / Report from OEM shall be submitted, Minimum 5 year OEM warranty, . Shape size and CCT shall be as approved by Engineer in charge. System lumen efficacy ≥105 and 120 lm/Watt output All as per pre approved by Engineer-in-charge.

-

-

-

... More
12 watt

40

1633

65320



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.