Public Works Department Tender

... More
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Public Works Department - PWD Tender

Works
Eprocure
Opening Date27 Sep 2019
Closing Date10 Oct 2019
Tender Amount₹ 55,46,847 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(j) Auto/Manual/Test/Off selector switch (ii) 2Nos. Over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay. (iii) 3 Sets of current transformers 15P 10 accuracy for protection and 15 VA class-I for metering (iv) Energy analyzer unit to indicate current voltage frequency power factor and KWH (v) indicating lamps for load on mains and load on set (vi)Fuse for instruments (vii)Battery charger, complete with transformer/rectifier, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment. (viii) Main supply failure monitor (ix) Supply failure timer (x) Restoration timer (xi) Control unit with three impulse automatic engine start/stop and failure to start lockout. (xii)Impulse counter with locking and reset facility. (xiii) ON/OFF/Control circuit switch with indicator. (xiv)Audio/Video annunciation for (a) High water temperature(b) Low lubricating oil pressure(c) Engine over speed

2

-

-

... More
Supplying and fixing of 400 Amp changeover switch in sheet enclosure power coated weather proof side handling operated complete etc as reqd.

2

-

-

... More
Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing masonry open duct as required. a). 3.5 x 240 sq mm aluminum armound conductor cable

300

-

-

... More
Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. a). 3½ X 240 sq. mm (62mm)

12

-

-

... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required

8

-

-

... More
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. Pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.

24

-

-

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

100

-

-

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ sub main wiring/ cable as required.

600

-

-

... More
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A

12

-

-

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.

8

-

-

... More
Fabrication, supplying and installation of outdoor type cubical feeder pillar of 350 mm deep made out of M.S. sheet 2 mm. Thick (14 SWG) duly compartmentalized having 4 strip aluminum busbar of 600 amp capacity double door with locking arrangement for protection from rain, dust duly fixed on M.S. angle iron frame work of size 50mm x 50mm x 6mm (NS) 90 cm long out of which 45 cm duly grouted in cement concrete 1:2:4 (1 cement 2 sand : 4 stone aggregate 20 mm) and having following accessories mounted inside the cubical panel including connection, interconnection with two nos. earth studs duly painted with one coat of red oxide and two coats of superior quality powder coated painting complete etc as required. (CPRI Approved) having following switch gears. (Minimum area = 1.30 Sqmtr) a) 400 amp 35 KA TPMCCB-1No. b) 150 amp 25KA TPMCCB - 4 No. C) Digital volt meter 0- 500 volt with selector switch 96 sq mm - 1 No. d) Digital amp meter 0-100 amp with selector switch 96 sqmm - 1 no. e) Indication lamp (RYB) set of 3 - 1 set f) Danger notice plate - 1 No. g) CT"s 100/5 - 1 set

1

-

-

... More
Fabrication, supplying and installation of outdoor type cubical feeder pillar of 350 mm deep made out of M.S. sheet 2 mm. Thick (14 SWG) duly compartmentalized having 4 strip aluminum busbar of 400 amp capacity double door with locking arrangement for protection from rain, dust duly fixed on M.S. angle iron frame work of size 50mm x 50mm x 6mm (NS) 90 cm long out of which 45 cm duly grouted in cement concrete 1:2:4 (1 cement 2 sand : 4 stone aggregate 20 mm) and having following accessories mounted inside the cubical panel including connection, interconnection with two nos. earth studs duly painted with one coat of red oxide and two coats of superior quality powder coated painting complete etc as required. (CPRI Approved) having following switch gears. (Minimum area = 1.20 Sqmtr) a) 250 amp 35 KA TPMCCB-1No. b) 150 amp 25KA TPMCCB - 2 No. c) 100 amp 16 KA TPMCCB - 2 No. d) Digital volt meter 0- 500 volt with selector switch 96 sq mm - 1 No. e) Digital amp meter 0-100 amp with selector switch 96 sqmm - 1 no. f) Indication lamp (RYB) set of 3 - 1 set g) Danger notice plate - 1 No. h) CT"s 100/5 - 1 set

1

-

-

... More
Fabrication, supplying and installation of outdoor type cubical feeder pillar of 350 mm deep made out of M.S. sheet 2 mm. Thick (14 SWG) duly compartmentalized having 4 strip aluminum busbar of 400 amp capacity double door with locking arrangement for protection from rain, dust duly fixed on M.S. angle iron frame work of size 50mm x 50mm x 6mm (NS) 90 cm long out of which 45 cm duly grouted in cement concrete 1:2:4 (1 cement 2 sand : 4 stone aggregate 20 mm) and having following accessories mounted inside the cubical panel including connection, interconnection with two nos. earth studs duly painted with one coat of red oxide and two coats of superior quality powder coated painting complete etc as required. (CPRI Approved) having following switch gearsa) 250 amp 35 KA TPMCCB-1No. b) 150 amp 25KA TPMCCB - 2 No.c) 100 amp 16 KA TPMCCB - 2 No. d) Digital volt meter 0- 500 volt with selector switch 96 sq mm - 1 No. e) Digital amp meter 0-100 amp with selector switch 96 sqmm - 1 no. f) Indication lamp (RYB) set of 3 - 1 set g) Danger notice plate - 1 No. h) CT"s 100/5 - 1 set

1

-

-

... More
Fabrication, supplying and installation of outdoor type cubical feeder pillar of 350 mm deep made out of M.S. sheet 2 mm. Thick (14 SWG) duly compartmentalized having 4 strip aluminum busbar of 200 amp capacity double door with locking arrangement for protection from rain, dust duly fixed on M.S. angle iron frame work of size 50mm x 50mm x 6mm (NS) 90 cm long out of which 45 cm duly grouted in cement concrete 1:2:4 (1 cement 2 sand : 4 stone aggregate 20 mm) and having following accessories mounted inside the cubical panel including connection, interconnection with two nos. earth studs duly painted with one coat of red oxide and two coats of superior quality powder coated painting complete etc as required. (CPRI Approved) having following switch gears. (Minimum area = 0.9 Sqmtr) a) 150 amp 25 KA TPMCCB-1No. b) 100 amp 16KA TPMCCB - 1 No. c) 63 amp 16 KA TPMCCB - 3 No. d) Digital volt meter 0- 500 volt with selector switch 96 sq mm - 1 No. e) Digital amp meter 0-100 amp with selector switch 96 sqmm - 1 no. f) Indication lamp (RYB) set of 3 - 1 set g) Danger notice plate - 1 No. h) CT"s 100/5 - 1 set

4

-

-

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. a) 90 mm dia (OD-90 mm & ID-76 mm nominal)

200

-

-

... More
Supplying and Laying of following size one number PVC insulated and PVC sheathed / XLPE armounrd Aluminum Conductor power cable of 1.1 kV grade on wall surface as required. (clamped with 1mm thick saddle) a). 3.5 x 35 Sq.mm armounrd Aluminum Conductor power cable

100

-

-

... More
Supplying and laying of following PVC insulated and PVC sheathed / XLPE armounrd Aluminum Conductor power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. a). 3.5 x 70 Sq.mm armounrd Aluminum Conductor power cable

100

-

-

... More
b). 3 x 16 Sq.mm armounrd Aluminum Conductor power cable

200

-

-

... More
S.I.T.C. of electric ceiling fans 1200 mm sweep shall be capacitor type, with double ball bearing complete with capacitor, 300mm down rods, canopies, three number blades made of aluminum alloy, suitable for operation on single phase, AC 230 volt, 50Hz supply and shall conform to class 1 of IS: 374 / 1979 (reaffirmed 2005) but without regulator. The ceiling fans shall be ISI marked and shall have BEE 5star Rating.

70

-

-

... More
S.I.T.C. of electric ceiling fans 1400 mm sweep shall be capacitor type, with double ball bearing complete with capacitor, 300mm down rods, canopies, three number blades made of aluminum alloy, suitable for operation on single phase, AC 230 volt, 50Hz supply and shall conform to class 1 of IS: 374 / 1979 (reaffirmed 2005) but without regulator. The ceiling fans shall be ISI marked and shall have BEE 5star Rating.

130

-

-

... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

200

-

-

... More
Supplying, Installation, Testing and Commissioning on wall/ceiling of 18 to 20 Watt 1200 mm long high efficiency LED liner batten luminaries having extruded aluminum housing and HET diffuser within built APFC driver having efficiency of driver 85% power factor 0.95, THD 10% with minimum 2.5 KV surge protection etc suitable for operation on 150 to 265 V single phase AC supply, having system efficacy 100 luman per watt and colour temperature of 5500 to 6500 K, CRI80 including connection with 1.5 Sq.mm PVC insulated copper conductor FRLS cable with the help of two Clamp sleeve complete etc as reqd.

200

-

-

... More
Supplying, Installation, Testing and Commissioning of 36 to 40 Watt recessed mounted LED luminaries of size 1200 mm (Length) x 300 mm (Width) housing made with white power coated CRCA sheet metal and polycarbonate diffuse suitable for operation on 150 to 265 Volt single phase AC supply having system efficiency not less than 100 luman per watt and colour temperature of 5500 to 6000 K, CRI80 with APFC drive having power factor0.90, THD10% and efficiency 2.5 KV surge protection. LED life with L-70 criteria shall be not less than 50000 burning hours etc including connection FRLS cable with the help of 4 No. fastener hook etc complete as reqd.

200

-

-

... More
Credit for old dismantled material received from the work

-

-

-

... More
Ceiling Fans

200

-

-

... More
Old Fitting

200

-

-

... More
Old recessed mounted Fitting

200

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.