Public Works Department Tender

If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Public Works Department - PWD Tender

Services
Electrical and Electronics
Electrical Works
Eprocure
Opening Date19 Jan 2024
Closing Date25 Jan 2024
Tender Amount₹ 81,25,631 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
b) 400 Amps, 36KA 4 Pole Microprocessor type MCCB with Ics=100%Icu with Microprocessor based releases for O/L, S/C & E/F protection complete with rotary handle - 1 Set

-

-

-

... More
c) Red, Yellow & blue LED for Phase and LEDs for ON, OFF and Trip Indicating lamps with protection MCBs - 1 Sets

-

-

-

... More
d) LED Multifunction Meter having V, A, F with required Accessories- 1 Set

-

-

-

... More
OUTGOINGS:-

-

-

-

... More
a) 250 Amps, 36KA 4 Pole Thermal Magnetic Release type MCCB with Ics=100%Icu for O/L, S/C protection complete with rotary handle - 3 No.

-

-

-

... More
b) 100 Amps, 25KA 4 Pole Thermal Magnetic Release type MCCB with Ics=100%Icu for O/L, S/C protection complete with rotary handle - 6 Nos.

-

-

-

... More
c) LED Multifunction Meter having V, A, F with required Accessories- 9 Set

-

-

-

... More
d) ON, OFF and Trip Indicating lamps with protection MCBs - 9 Set

-

-

-

... More
e) 16 A Single Phase socket outlet on the panel body with IP-65 rating and suitable rating double pole protection MCB - 2 Set

-

-

-

... More
f) Danger notice plate =1 No.

-

-

-

... More
(NOTE:- All MCCB's shall be provided with phase barriers, phase spreaders complete as reqd. Ics =100% Icu for all MCCBs)

1

461571

461571

... More
Supplying, installation, testing & commissioning of factory assembled outdoor type hut shaped double door both side openable feeder pillar dust & vermin proof powder coated with degree of protection of IP 54 self supported suitable for 3 phase 4 wire, 415 volt AC supply and having front area not less than 2.50 Sqmtr. and 500 mm deep nominal size fabricated out of 2mm thick CRCA sheet with locking arrangement i/c 3 mm thick sheet in bottom for gland plates, supplying & fixing following accessories as mentioned below i/c 500 AMP Aluminium bus bars inter connection, arrangement for cable entry/support/ termination 2 Nos. earthing stud inter connection with 25mm x 5mmm Copper strip (externally) 50mm x 50mm x 6mm MS angle iron base frame duly welded 100cm long welded with 4 Nos legs for grouting in foundation i/c painting, Pdg. of 1:3:6 (1 Cement : 3 Coarse sand : 6 Aggregate stone 20mm nominal size) foundation (600mm below the ground level and 400mm above the ground level) it should be covered with Aprin plate (400mm above the ground) not less than 3 mm thick etc. complete as required, including dismantling and buyback of existing old damaged panel with connection of cables etc. as required

-

-

-

... More
INCOMING:-

-

-

-

... More
a) Manual On Load Changeover Switch 400 A and all other required accessories - 1 Set.

-

-

-

... More
b) 400 Amps, 36KA 4 Pole Microprocessor type MCCB with Ics=100%Icu with Microprocessor based releases for O/L, S/C & E/F protection complete with rotary handle - 1 Set

-

-

-

... More
c) Red, Yellow & blue LED for Phase and LEDs for ON, OFF and Trip Indicating lamps with protection MCBs - 1 Sets

-

-

-

... More
d) LED Multifunction Meter having V, A, F with required Accessories- 1 Set

-

-

-

... More
OUTGOINGS:-

-

-

-

... More
a) 250 Amps, 36KA 4 Pole Thermal Magnetic Release type MCCB with Ics=100%Icu for O/L, S/C protection complete with rotary handle - 3 No.

-

-

-

... More
b) 200 Amps, 25KA 4 Pole Thermal Magnetic Release type MCCB with Ics=100%Icu for O/L, S/C protection complete with rotary handle - 2 Nos.

-

-

-

... More
c) 100 Amps, 25KA 4 Pole Thermal Magnetic Release type MCCB with Ics=100%Icu for O/L, S/C protection complete with rotary handle - 4 Nos.

-

-

-

... More
d) LED Multifunction Meter having V, A, F with required Accessories- 9 Set

-

-

-

... More
e) ON, OFF and Trip Indicating lamps with protection MCBs - 9 Set

-

-

-

... More
f) 16 A Single Phase socket outlet on the panel body with IP-65 rating and suitable rating double pole protection MCB - 2 Set

-

-

-

... More
g) Danger notice plate =1 No.

-

-

-

... More
(NOTE:- (a) All MCCB's shall be provided with phase barriers, phase spreaders complete as reqd.

-

-

-

... More
(b) Ics =100% Icu for all MCCBs)

2

978516

489258

... More
Supplying, installation, testing & commissioning of factory assembled outdoor type hut shaped double door both side openable feeder pillar dust & vermin proof powder coated with degree of protection of IP 54 self supported suitable for 3 phase 4 wire, 415 volt AC supply and having front area not less than 2.50 Sqmtr. and 500 mm deep nominal size fabricated out of 2mm thick CRCA sheet with locking arrangement i/c 3 mm thick sheet in bottom for gland plates, supplying & fixing following accessories as mentioned below i/c 500 AMP Aluminium bus bars inter connection, arrangement for cable entery/support/ termination 2 Nos. earthing stud inter connection with 25mm x 5mmm Copper strip (externally) 50mm x 50mm x 6mm MS angle iron base frame duly welded 100cm long welded with 4 Nos legs for grouting in foundation i/c painting, Pdg. of 1:3:6 (1 Cement : 3 Coarse sand : 6 Aggregate stone 20mm nominal size) foundation (600mm below the ground level and 400mm above the ground level) it should be covered with Aprin plate (400mm above the ground) not less than 3 mm thick etc. complete as required, including dismantling and buyback of existing old damaged panel with connection of cables etc. as required

-

-

-

... More
INCOMING:-

-

-

-

... More
a) 400 Amps, 36KA 4 Pole Microprocessor type MCCB with Ics=100%Icu with Microprocessor based releases for O/L, S/C & E/F protection complete with rotary handle - 1 Set

-

-

-

... More
b) Red, Yellow & blue LED for Phase and LEDs for ON, OFF and Trip Indicating lamps with protection MCBs - 1 Sets

-

-

-

... More
c) LED Multifunction Meter having V, A, F with required Accessories- 1 Set

-

-

-

... More
OUTGOINGS:-

-

-

-

... More
a) 250 Amps, 36KA 4 Pole Thermal Magnetic Release type MCCB with Ics=100%Icu for O/L, S/C protection complete with rotary handle - 2 No.

-

-

-

... More
b) 200 Amps, 25KA 4 Pole Thermal Magnetic Release type MCCB with Ics=100%Icu for O/L, S/C protection complete with rotary handle - 3 No.

-

-

-

... More
c) 100 Amps, 25KA 4 Pole Thermal Magnetic Release type MCCB with Ics=100%Icu for O/L, S/C protection complete with rotary handle - 4 Nos.

-

-

-

... More
d) LED Multifunction Meter having V, A, F with required Accessories- 9 Set

-

-

-

... More
e) ON, OFF and Trip Indicating lamps with protection MCBs - 9 Set

-

-

-

... More
f) 63 A Four Pole 10KA, C Curve MCBs - 4 Set

-

-

-

... More
g) 32 A Double Pole 10KA, C Curve MCBs - 2 Set

-

-

-

... More
h) 16 A Single Phase socket outlet on the panel body with IP-65 rating and suitable rating double pole protection MCB - 2 Set

-

-

-

... More
i) Danger notice plate =1 No.

-

-

-

... More
(NOTE:- (a) All MCCB's shall be provided with phase barriers, phase spreaders complete as reqd.

-

-

-

... More
(b) Ics =100% Icu for all MCCBs)

1

504639

504639

... More
Supplying, installation, testing & commissioning of factory assembled outdoor type hut shaped double door both side openable feeder pillar dust & vermin proof powder coated with degree of protection of IP 54 self supported suitable for 3 phase 4 wire, 415 volt AC supply and having front area not less than 2.50 Sqmtr. and 500 mm deep nominal size fabricated out of 2mm thick CRCA sheet with locking arrangement i/c 3 mm thick sheet in bottom for gland plates, supplying & fixing following accessories as mentioned below i/c 500 AMP Aluminium bus bars inter connection, arrangement for cable entry/support/ termination 2 Nos. earthing stud inter connection with 25mm x 5mmm Copper strip (externally) 50mm x 50mm x 6mm MS angle iron base frame duly welded 100cm long welded with 4 Nos legs for grouting in foundation i/c painting, Pdg. of 1:3:6 (1 Cement : 3 Coarse sand : 6 Aggregate stone 20mm nominal size) foundation (600mm below the ground level and 400mm above the ground level) it should be covered with Aprin plate (400mm above the ground) not less than 3 mm thick etc. complete as required , including dismantling and buyback of existing old damaged panel with connection of cables etc. as required

-

-

-

... More
INCOMING:-

-

-

-

... More
a) Manual On Load Changeover Switch 400 A and all other required accessories - 1 Set.

-

-

-

... More
b) 400 Amps, 36KA 4 Pole Microprocessor type MCCB with Ics=100%Icu with Microprocessor based releases for O/L, S/C & E/F protection complete with rotary handle - 1 Set

-

-

-

... More
c) Red, Yellow & blue LED for Phase and LEDs for ON, OFF and Trip Indicating lamps with protection MCBs - 1 Sets

-

-

-

... More
d) LED Multifunction Meter having V, A, F with required Accessories- 1 Set

-

-

-

... More
OUTGOINGS:-

-

-

-

... More
a) 250 Amps, 36KA 4 Pole Thermal Magnetic Release type MCCB with Ics=100%Icu for O/L, S/C protection complete with rotary handle - 3 No.

-

-

-

... More
b) 100 Amps, 25KA 4 Pole Thermal Magnetic Release type MCCB with Ics=100%Icu for O/L, S/C protection complete with rotary handle - 6 Nos.

-

-

-

... More
c) LED Multifunction Meter having V, A, F with required Accessories- 9 Set

-

-

-

... More
d) ON, OFF and Trip Indicating lamps with protection MCBs - 9 Set

-

-

-

... More
e) 63 A Four Pole 10KA, C Curve MCBs - 4 Set

-

-

-

... More
f) 32 A Double Pole 10KA, C Curve MCBs - 2 Set

-

-

-

... More
g) 16 A Single Phase socket outlet on the panel body with IP-65 rating and suitable rating double pole protection MCB - 2 Set

-

-

-

... More
h) Danger notice plate =1 No.

-

-

-

... More
(NOTE:- (a) All MCCB's shall be provided with phase barriers, phase spreaders complete as reqd.

-

-

-

... More
(b) Ics =100% Icu for all MCCBs)

1

478491

478491

... More
Supplying, installation, testing & commissioning of factory assembled outdoor type hut shaped double door both side openable feeder pillar dust & vermin proof powder coated with degree of protection of IP 54 self supported suitable for 3 phase 4 wire, 415 volt AC supply and having front area not less than 2.50 Sqmtr. and 500 mm deep nominal size fabricated out of 2mm thick CRCA sheet with locking arrangement i/c 3 mm thick sheet in bottom for gland plates, supplying & fixing following accessories as mentioned below i/c 500 AMP Aluminium bus bars inter connection, arrangement for cable entry/support/ termination 2 Nos. earthing stud inter connection with 25mm x 5mmm Copper strip (externally) 50mm x 50mm x 6mm MS angle iron base frame duly welded 100cm long welded with 4 Nos legs for grouting in foundation i/c painting, Pdg. of 1:3:6 (1 Cement : 3 Coarse sand : 6 Aggregate stone 20mm nominal size) foundation (600mm below the ground level and 400mm above the ground level) it should be covered with Aprin plate (400mm above the ground) not less than 3 mm thick etc. complete as required , including dismantling and buyback of existing old damaged panel with connection of cables etc. as required

-

-

-

... More
INCOMING:-

-

-

-

... More
a) Manual On Load Changeover Switch 400 A and all other required accessories - 1 Set.

-

-

-

... More
b) 400 Amps, 36KA 4 Pole Microprocessor type MCCB with Ics=100%Icu with Microprocessor based releases for O/L, S/C & E/F protection complete with rotary handle - 1 Set

-

-

-

... More
c) Red, Yellow & blue LED for Phase and LEDs for ON, OFF and Trip Indicating lamps with protection MCBs - 1 Sets

-

-

-

... More
d) LED Multifunction Meter having V, A, F with required Accessories- 1 Set

-

-

-

... More
OUTGOINGS:-

-

-

-

... More
a) 250 Amps, 36KA 4 Pole Thermal Magnetic Release type MCCB with Ics=100%Icu for O/L, S/C protection complete with rotary handle - 3 No.

-

-

-

... More
b) 200 Amps, 25KA 4 Pole Thermal Magnetic Release type MCCB with Ics=100%Icu for O/L, S/C protection complete with rotary handle - 2 Nos.

-

-

-

... More
c) 100 Amps, 25KA 4 Pole Thermal Magnetic Release type MCCB with Ics=100%Icu for O/L, S/C protection complete with rotary handle - 4 Nos.

-

-

-

... More
d) LED Multifunction Meter having V, A, F with required Accessories- 9 Set

-

-

-

... More
e) ON, OFF and Trip Indicating lamps with protection MCBs - 9 Set

-

-

-

... More
f) 63 A Four Pole 10KA, C Curve MCBs - 4 Set

-

-

-

... More
g) 32 A Double Pole 10KA, C Curve MCBs - 2 Set

-

-

-

... More
h) 16 A Single Phase socket outlet on the panel body with IP-65 rating and suitable rating double pole protection MCB - 2 Set

-

-

-

... More
i) Danger notice plate =1 No.

-

-

-

... More
(NOTE:- (a) All MCCB's shall be provided with phase barriers, phase spreaders complete as reqd.

-

-

-

... More
(b) Ics =100% Icu for all MCCBs)

1

506177

506177

... More
Supplying, installation, testing & commissioning of factory assembled outdoor type hut shaped double door both side openable feeder pillar dust & vermin proof powder coated with degree of protection of IP 54 self supported suitable for 3 phase 4 wire, 415 volt AC supply and having front area not less than 2.30 Sqmtr. and 500 mm deep nominal size fabricated out of 2mm thick CRCA sheet with locking arrangement i/c 3 mm thick sheet in bottom for gland plates, supplying & fixing following accessories as mentioned below i/c 500 AMP Aluminium bus bars inter connection, arrangement for cable entry/support/ termination 2 Nos. earthing stud inter connection with 25mm x 5mmm Copper strip (externally) 50mm x 50mm x 6mm MS angle iron base frame duly welded 100cm long welded with 4 Nos legs for grouting in foundation i/c painting, Pdg. of 1:3:6 (1 Cement : 3 Coarse sand : 6 Aggregate stone 20mm nominal size) foundation (600mm below the ground level and 400mm above the ground level) it should be covered with Aprin plate (400mm above the ground) not less than 3 mm thick etc. complete as required, including dismantling and buyback of existing old damaged panel with connection of cables etc. as required

-

-

-

... More
INCOMING:-

-

-

-

... More
a) Manual On Load Changeover Switch 250 A and all other required accessories - 1 Set.

-

-

-

... More
b) 250 Amps, 36KA 4 Pole Microprocessor type MCCB with Ics=100%Icu with Microprocessor based releases for O/L, S/C & E/F protection complete with rotary handle - 1 Set

-

-

-

... More
c) Red, Yellow & blue LED for Phase and LEDs for ON, OFF and Trip Indicating lamps with protection MCBs - 1 Sets

-

-

-

... More
d) LED Multifunction Meter having V, A, F with required Accessories- 1 Set

-

-

-

... More
OUTGOINGS:-

-

-

-

... More
a) 200 Amps, 25KA 4 Pole Thermal Magnetic Release type MCCB with Ics=100%Icu for O/L, S/C protection complete with rotary handle - 1 No.

-

-

-

... More
b) 100 Amps, 25KA 4 Pole Thermal Magnetic Release type MCCB with Ics=100%Icu for O/L, S/C protection complete with rotary handle - 6 Nos.

-

-

-

... More
c) 63 A Four Pole 10KA, C Curve MCBs - 4 Set

-

-

-

... More
d) 32 A Double Pole 10KA, C Curve MCBs - 2 Set

-

-

-

... More
e) LED Multifunction Meter having V, A, F with required Accessories- 7 Set

-

-

-

... More
f) ON, OFF and Trip Indicating lamps with protection MCBs - 7 Set

-

-

-

... More
g) 16 A Single Phase socket outlet on the panel body with IP-65 rating and suitable rating double pole protection MCB - 2 Set

-

-

-

... More
h) Danger notice plate =1 No.

-

-

-

... More
(NOTE:- (a) All MCCB's shall be provided with phase barriers, phase spreaders complete as reqd.

-

-

-

... More
(b) Ics =100% Icu for all MCCBs)

1

364669

364669

... More
Supplying, installation, testing & commissioning of factory assembled outdoor type hut shaped double door both side openable feeder pillar dust & vermin proof powder coated with degree of protection of IP 54 self supported suitable for 3 phase 4 wire, 415 volt AC supply and having front area not less than 2.50 Sqmtr. and 500 mm deep nominal size fabricated out of 2mm thick CRCA sheet with locking arrangement i/c 3 mm thick sheet in bottom for gland plates, supplying & fixing following accessories as mentioned below i/c 500 AMP Aluminium bus bars inter connection, arrangement for cable entry/support/ termination 2 Nos. earthing stud inter connection with 25mm x 5mmm Copper strip (externally) 50mm x 50mm x 6mm MS angle iron base frame duly welded 100cm long welded with 4 Nos legs for grouting in foundation i/c painting, Pdg. of 1:3:6 (1 Cement : 3 Coarse sand : 6 Aggregate stone 20mm nominal size) foundation (600mm below the ground level and 400mm above the ground level) it should be covered with Aprin plate (400mm above the ground) not less than 3 mm thick etc. complete as required , including dismantling and buyback of existing old damaged panel with connection of cables etc. as required

-

-

-

... More
INCOMING:-

-

-

-

... More
a) Manual On Load Changeover Switch 250 A and all other required accessories - 1 Set.

-

-

-

... More
b) 250 Amps, 36KA 4 Pole Microprocessor type MCCB with Ics=100%Icu with Microprocessor based releases for O/L, S/C & E/F protection complete with rotary handle - 1 Set

-

-

-

... More
c) Red, Yellow & blue LED for Phase and LEDs for ON, OFF and Trip Indicating lamps with protection MCBs - 1 Sets

-

-

-

... More
d) LED Multifunction Meter having V, A, F with required Accessories- 1 Set

-

-

-

... More
OUTGOINGS:-

-

-

-

... More
a) 200 Amps, 25KA 4 Pole Thermal Magnetic Release type MCCB with Ics=100%Icu for O/L, S/C protection complete with rotary handle - 2 No.

-

-

-

... More
b) 100 Amps, 25KA 4 Pole Thermal Magnetic Release type MCCB with Ics=100%Icu for O/L, S/C protection complete with rotary handle - 2 Nos.

-

-

-

... More
c) 63 A Four Pole 10KA, C Curve MCBs - 4 Set

-

-

-

... More
d) 32 A Double Pole 10KA, C Curve MCBs - 2 Set

-

-

-

... More
e) LED Multifunction Meter having V, A, F with required Accessories- 4 Set

-

-

-

... More
f) ON, OFF and Trip Indicating lamps with protection MCBs - 4 Set

-

-

-

... More
g) Fully Automatic Star Delta Starter Suitable up to 10 HP motor complete with Electronic motor protection Relay, Thermal Overload relay, Single Phase protection and other required accessories - 2 Set

-

-

-

... More
h) DOL Starter Suitable up to 7.5 HP motor complete with Electronic motor protection Relay, Thermal Overload relay, Single Phase protection and other required accessories - 4 Set

-

-

-

... More
i) 16 A Single Phase socket outlet on the panel body with IP-65 rating and suitable rating double pole protection MCB - 2 Set

-

-

-

... More
j) Danger notice plate =1 No.

-

-

-

... More
(NOTE:- (a) All MCCB's shall be provided with phase barriers, phase spreaders complete as reqd.

-

-

-

... More
(b) Ics =100% Icu for all MCCBs)

1

490906

490906

... More
Supplying, installation, testing & commissioning of factory assembled outdoor type hut shaped double door both side openable feeder pillar dust & vermin proof powder coated with degree of protection of IP 54 self supported suitable for 3 phase 4 wire, 415 volt AC supply and having front area not less than 2.30 Sqmtr. and 500 mm deep nominal size fabricated out of 2mm thick CRCA sheet with locking arrangement i/c 3 mm thick sheet in bottom for gland plates, supplying & fixing following accessories as mentioned below i/c 500 AMP Aluminium bus bars inter connection, arrangement for cable entery/support/ termination 2 Nos. earthing stud inter connection with 25mm x 5mmm Copper strip (externally) 50mm x 50mm x 6mm MS angle iron base frame duly welded 100cm long welded with 4 Nos legs for grouting in foundation i/c painting, Pdg. of 1:3:6 (1 Cement : 3 Coarse sand : 6 Aggregate stone 20mm nominal size) foundation (600mm below the ground level and 400mm above the ground level) it should be covered with Aprin plate (400mm above the ground) not less than 3 mm thick etc. complete as required, including dismantling and buyback of existing old damaged panel with connection of cables etc. as required

-

-

-

... More
INCOMING:-

-

-

-

... More
a) Manual On Load Changeover Switch 400 A and all other required accessories - 1 Set.

-

-

-

... More
b) 400 Amps, 36KA 4 Pole Microprocessor type MCCB with Ics=100%Icu with Microprocessor based releases for O/L, S/C & E/F protection complete with rotary handle - 1 Set

-

-

-

... More
c) Red, Yellow & blue LED for Phase and LEDs for ON, OFF and Trip Indicating lamps with protection MCBs - 1 Sets

-

-

-

... More
d) LED Multifunction Meter having V, A, F with required Accessories- 1 Set

-

-

-

... More
OUTGOINGS:-

-

-

-

... More
a) 250 Amps, 36KA 4 Pole Thermal Magnetic Release type MCCB with Ics=100%Icu for O/L, S/C protection complete with rotary handle - 1 No.

-

-

-

... More
b) 200 Amps, 25KA 4 Pole Thermal Magnetic Release type MCCB with Ics=100%Icu for O/L, S/C protection complete with rotary handle - 3 Nos.

-

-

-

... More
c) 100 Amps, 25KA 4 Pole Thermal Magnetic Release type MCCB with Ics=100%Icu for O/L, S/C protection complete with rotary handle - 3 Nos.

-

-

-

... More
d) LED Multifunction Meter having V, A, F with required Accessories- 7 Set

-

-

-

... More
e) ON, OFF and Trip Indicating lamps with protection MCBs - 7 Set

-

-

-

... More
f) 63 A Four Pole 10KA, C Curve MCBs - 6 Set

-

-

-

... More
g) 32 A Double Pole 10KA, C Curve MCBs - 2 Set

-

-

-

... More
h) 16 A Single Phase socket outlet on the panel body with IP-65 rating and suitable rating double pole protection MCB - 2 Set

-

-

-

... More
i) Danger notice plate =1 No.

-

-

-

... More
(NOTE:- (a) All MCCB's shall be provided with phase barriers, phase spreaders complete as reqd.

-

-

-

... More
(b) Ics =100% Icu for all MCCBs)

2

868430

434215

... More
Supplying, installation, testing & commissioning of factory assembled outdoor type hut shaped double door both side openable feeder pillar dust & vermin proof powder coated with degree of protection of IP 54 self supported suitable for 3 phase 4 wire, 415 volt AC supply and having front area not less than 2.30 Sqmtr. and 500 mm deep nominal size fabricated out of 2mm thick CRCA sheet with locking arrangement i/c 3 mm thick sheet in bottom for gland plates, supplying & fixing following accessories as mentioned below i/c 500 AMP Aluminium bus bars inter connection, arrangement for cable entry/support/ termination 2 Nos. earthing stud inter connection with 25mm x 5mmm Copper strip (externally) 50mm x 50mm x 6mm MS angle iron base frame duly welded 100cm long welded with 4 Nos legs for grouting in foundation i/c painting, Pdg. of 1:3:6 (1 Cement : 3 Coarse sand : 6 Aggregate stone 20mm nominal size) foundation (600mm below the ground level and 400mm above the ground level) it should be covered with Aprin plate (400mm above the ground) not less than 3 mm thick etc. complete as required, including dismantling and buyback of existing old damaged panel with connection of cables etc. as required

-

-

-

... More
INCOMING:-

-

-

-

... More
a) Manual On Load Changeover Switch 400 A and all other required accessories - 1 Set.

-

-

-

... More
b) 400 Amps, 36KA 4 Pole Microprocessor type MCCB with Ics=100%Icu with Microprocessor based releases for O/L, S/C & E/F protection complete with rotary handle - 1 Set

-

-

-

... More
c) Red, Yellow & blue LED for Phase and LEDs for ON, OFF and Trip Indicating lamps with protection MCBs - 1 Sets

-

-

-

... More
d) LED Multifunction Meter having V, A, F with required Accessories- 1 Set

-

-

-

... More
OUTGOINGS:-

-

-

-

... More
a) 250 Amps, 36KA 4 Pole Thermal Magnetic Release type MCCB with Ics=100%Icu for O/L, S/C protection complete with rotary handle - 2 No.

-

-

-

... More
b) 200 Amps, 25KA 4 Pole Thermal Magnetic Release type MCCB with Ics=100%Icu for O/L, S/C protection complete with rotary handle - 1 Nos.

-

-

-

... More
c) 100 Amps, 25KA 4 Pole Thermal Magnetic Release type MCCB with Ics=100%Icu for O/L, S/C protection complete with rotary handle - 7 Nos.

-

-

-

... More
d) LED Multifunction Meter having V, A, F with required Accessories- 7 Set

-

-

-

... More
e) ON, OFF and Trip Indicating lamps with protection MCBs - 7 Set

-

-

-

... More
f) 63 A Four Pole 10KA, C Curve MCBs - 6 Set

-

-

-

... More
g) 32 A Double Pole 10KA, C Curve MCBs - 2 Set

-

-

-

... More
h) 16 A Single Phase socket outlet on the panel body with IP-65 rating and suitable rating double pole protection MCB - 2 Set

-

-

-

... More
i) Danger notice plate =1 No.

-

-

-

... More
(NOTE:- (a) All MCCB's shall be provided with phase barriers, phase spreaders complete as reqd.

-

-

-

... More
(b) Ics =100% Icu for all MCCBs)

2

990162

495081

... More
Supplying, installation, testing & commissioning of factory assembled outdoor type hut shaped double door both side openable feeder pillar dust & vermin proof powder coated with degree of protection of IP 54 self supported suitable for 3 phase 4 wire, 415 volt AC supply and having front area not less than 1.30 Sqmtr. and 400 mm deep nominal size fabricated out of 2mm thick CRCA sheet with locking arrangement i/c 3 mm thick sheet in bottom for gland plates, supplying & fixing following accessories as mentioned below i/c 200 AMP Aluminium bus bars inter connection, arrangement for cable entry/support/ termination 2 Nos. earthing stud inter connection with 25mm x 5mmm Copper strip (externally) 50mm x 50mm x 6mm MS angle iron base frame duly welded 100cm long welded with 4 Nos legs for grouting in foundation i/c painting, Pdg. of 1:3:6 (1 Cement : 3 Coarse sand : 6 Aggregate stone 20mm nominal size) foundation (600mm below the ground level and 400mm above the ground level) it should be covered with Aprin plate (400mm above the ground) not less than 3 mm thick etc. complete as required, including dismantling and buyback of existing old damaged panel with connection of cables etc. as required.

-

-

-

... More
INCOMING:-

-

-

-

... More
a) 100 Amps, 25KA 4 Pole Thermal Magnetic Release type MCCB with Ics=100%Icu for O/L, S/C protection complete with rotary handle - 1 Nos.

-

-

-

... More
b) Red, Yellow & blue LED for Phase and LEDs for ON, OFF and Trip Indicating lamps with protection MCBs - 1 Sets

-

-

-

... More
c) LED Multifunction Meter having V, A, F with required Accessories- 1 Set

-

-

-

... More
OUTGOINGS:-

-

-

-

... More
a) 63 A Four Pole 10KA, C Curve MCBs - 4 Set

-

-

-

... More
b) 32 A Double Pole 10KA, C Curve MCBs - 2 Set

-

-

-

... More
c) Fully Automatic Star Delta Starter Suitable up to 10 HP motor complete with Electronic motor protection Relay, Thermal Overload relay, Single Phase protection and other required accessories - 3 Set

-

-

-

... More
d) LED Multifunction Meter having V, A, F with required Accessories- 3 Set

-

-

-

... More
e) ON, OFF and Trip Indicating lamps with protection MCBs - 3 Set

-

-

-

... More
f) 16 A Single Phase socket outlet on the panel body with IP-65 rating and suitable rating double pole protection MCB - 2 Set

-

-

-

... More
g) Danger notice plate =1 No.

-

-

-

... More
(NOTE:- (a) All MCCB's shall be provided with phase barriers, phase spreaders complete as reqd.

-

-

-

... More
(b) Ics =100% Icu for all MCCBs)

1

213998

213998

... More
Supplying & Laying of one number PVC insulated and PVC sheathed / XLPE power aluminium conductor armoured cable of 1.1 kV grade of following size On the existing Surface etc as required.. (i) 3.5 x 300

500

1564000

3128

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. i) 3½ X 300 sq. mm (70mm)

16

20336

1271

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

24

353136

14714

... More
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.

150

8100

54

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. i) 375 mm width X 50 mm depth X 2.0 mm thickness

250

322500

1290



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.