Public Works Department Tender

If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Public Works Department - PWD Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date7 Jan 2025
Closing Soon14 Jan 2025
Tender Amount₹ 4,23,32,160 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift.

1658

196

324968

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level :

-

-

-

... More
Concrete of M10 grade with minimum cement content of 220 kg /cum

125

8835

1104394

... More
Centering and shuttering including strutting, propping etc. and removal of form for

-

-

-

... More
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

10120

842

8526100

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.

-

-

-

... More
Thermo-Mechanically Treated bars of grade Fe-500D or more.

97300

107

10493805

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level :

-

-

-

... More
Concrete of M25 grade with minimum cement content of 330 kg /cum

973

9504

9248122

... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :

-

-

-

... More
Two or more coats on new work

5567

155

867895

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

5567

156

868730

... More
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.

629

263

166025

... More
Providing and erecting 2.00 metre high temporary barricading at site; each panel of size 2.50mx2.00m made of 40x40x6mm angle iron or 50x50x3mm hollow MS tube posts/horizontal members/bracings covered with 1.63mm thick MS sheet. The sheet shall be fixed with 30x5mm MS flat by suitable welding/riveting. The panels shall be made so that gap of 50cm above the ground is available making overall height as 2.5m. MS channel ISLC 75 @ 5.70 kg/m, 50cm long shall be provided at the bottom having oval shaped holes of size 50x25mm at both ends with 50cm long MS angle 40x40x6mm bracing. Suitable arrangement shall be made to fix the barricading to avoid from overturning by providing 250mm long expansion fasteners at both ends. The work shall be executed as per drawing/direction of Engineer-in-Charge which includes writing and painting, arrangement for traffic diversion such as traffic signals during construction at site for day and night, glow lamps, reflective signs, marking, flags, caution tape as directed by the Engineer-in-Charge. The barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. Rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job. The barricading shall not be removed without prior approval of Engineer-in-Charge. (Note :- One time payment shall be made for providing barricading from start of work till completion of work i/c shifting. The barricading provided shall remain to be the property of the contractor on completion of the work).

400

3439

1375800

... More
Taking out existing kerb stones of all types from footpath/ central verge, including removal of mortar etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.

4093

39

161060

... More
Add @ 3.00% Cost Index on DSR 2023

1

997270

997270

... More
Modified Estimated Cost due to correction in GST Rate @ 0.973 =(Estimated cost based on DSR 2023 items *0.973) = (-) (34239591*0.027= 924469)

1

924469

-924469

... More
Credit for old/damaged dismantled kerb stone received from site as per direction of Engineer-in-charge (Dismantled kerb stone will be property of the contractor).

92

3080

-283360

... More
Credit for old SFRC cement railing of central verge received from taking out from site.(Dismantled old SFRC cement railing will be property of the contractor).

1433

200

-286600

... More
Taking out existing SFRC cement railing from central verge by demolishing cement concrete block of size 30x30x30 cm and stacking at site within 50 mtr lead as per the direction of Engineer-in-charge.

2865

107

307415

... More
Providing and Fixing of Flexible Median Markers which shall be made of combination of tough, high impact resistant molded thermoplastic body along with florescent yellow color retro-reflective type XI sheeting with minimum exposed reflective area 285 square mm and with rebound property. The reflective sheeting should confirm to Type XI Florescent Yellow sheeting as per IRC 67 2012 and ASTM D4956-11. The flexible median marker shall have overall height of minimum 180 mm, body thickness of minimum 2mm and shank depth of minimum 30mm. The retro-reflective sheeting shall be on both sides of the Flexible Median Marker and shall be edge protected with no exposed edges which will prevent edge lifting, vandalism, sheeting damage, etc. The edge of sheeting should not come out easily by putting nails, sharp objects etc. The logo of the manufacturer shall be embossed on either side of the body. The plastics used for the molding the flexible median marker shall have a minimum notched Izod Impact strength value of 4.11J/cm (@thickness 3.17mm) at room temperature, tested in accordance with ASTM D256. The product design has to with stand all natural impacts and should not get damaged if any pedestrian stamp on top of it intentionally or unintentionally. The product should bend up to 90 degree on both sides without breakage or damage. The product shall be povided with 3 year outdoor weathering report as per ASTM & IRC Standards & 10 year warranty confirmation as per IRC 67:2012 standards for the reflective sheeting used in product. The product shall have accredition with IRC.

820

193

158916

... More
Horticulture Work

-

-

-

... More
Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment).

413

515

212943

... More
Fine dressing of the ground.

688

3

2546

... More
Flooding the ground with water including making kiaries and dismantling the same.

688

2

1445

... More
Excavation in dumped stones or malba including stacking of serviceable and unserviceable material separately and disposal of unserviceable material, lead up to 50 m and lift up to 1.5 m, disposed material to be neatly dressed.

206

511

105348

... More
Supplying and stacking of well decayed cattle manure at site including royalty and carriage upto 5 k.m.lead complete (Cattle manure measured in stacks will reduced by 8% for Payment).

17

247

4208

... More
Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water)

-

-

-

... More
Shrubs Plants

6183

3

22568

... More
Providing and stacking of Bougainvillea (Variety Butiana, Lady Mary Baring, Mahara,Mohan,Scarlet Queen, Variegated, Glabra Formosa, Peruviana Odissi, Paratha, Subhra,Thimma, Spectabilis L.N Birla, Refulgens) of height 30 cm. to 45 cm. with 2-3 branches in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge @ 9 plant in one sqm

6183

40

247320

... More
Add 10.21 % Cost Index on DSR 2020

1

60890

60890

... More
Add 1.00 % Labour Welfare Cess on DSR 2020

1

6573

6573

... More
Add 18.00 % GST(MF@0.2127%) on DSR 2020

1

141199

141199

... More
Modified Estimated Cost due to correction in GST Rate @ 0.973 =(Estimated cost based on DSR 2023 items *0.973) = (-) (805040*0.027= 21736)

1

21736

-21736

... More
Electrical Work

-

-

-

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required.

5000

42

210000

... More
Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.

10

6855

68550

... More
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 meter below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm)

2400

144

345600

... More
Supplying and making indoor end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.

-

-

-

... More
4 x 25 sq.mm (28 mm)

8

315

2520

... More
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.

-

-

-

... More
4 X 25 sq. mm

4

2478

9912

... More
Add GST (12 to 18%) Factor @6.33%

1

40296

40296

... More
Modified Estimated Cost due to correction in GST Rate @ 0.973 =(Estimated cost based on DSR 2023 items *0.973) = (-) (676878*0.027= 18276)

1

18276

-18276

... More
Dismantlling of existing street light feeder piller from installed position including shifting the feeder piller from site to store by mechanicale means with proper safety, opening of cable connections etc complete as required.

1

3811

3811

... More
Dismantlling of existing street light octagonal pole of lenght 10m/12m with bracket including shifting the pole from site to store by mechanicale means using hydra crane with proper safety, opening of cable connection etc complete as required.

56

2405

134680

... More
Dismantling of old Concrete pole Foundation upto ground level i/c cutting of bolt, disconnection of cable, dispossing off the malba / debries from the site at suitable place etc complete as required.

58

2145

124410

... More
Supplying, laying & fixing of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in recess or on surface etc. complete as required.

-

-

-

... More
a) 63 mm dia (OD-63 mm & ID-51 mm nominal)

2500

202

505000

... More
Making / drlling bore hole in horizontal direction across the road with the help of mouling equipment by trench less technology i/c excavation of pits of required size at suitable distance to facilitate operation of mouling equipment, providing and laying 100 mm OD HDPE pipes (ISI Marked) with pressure rating of 6Kg/Sq.c.m in the bore i/c jointing of pipe, cleaning of pipe, covering open end of pipe etc, refilling of pit, making good the damages etc. complete as per direction of Engineer-In-Charge.

50

1055

52750

... More
Supplying & fixing of SMC junction box of size 400mm x 300mm x 190mm with cover on surface or in recess including making hole for pipe / cable etc. complete as reqd.

58

3346

194068

... More
Supplying and laying of one number PVC insulated and PVC sheated/XLPE aluminium conductor armoured power cable of 1.1 KV grade of following size in existing HDPE pipe etc as reqd.

-

-

-

... More
a) 4 x 16 sq.mm

2548

367

935116

... More
b) 4 x 25 sq.mm

700

442

309400

... More
Providing & laying foundation of size 750 mm (L) x 750 mm (W) and 1800 mm (D) for 12 m height octagonal pole by laying in position M-20 (1:2:4) reinforced cement concrete including providing cutting, bending and placing in position reinforcement with TMT bars of 12 mm dia -2100 mm long (approx.)-8 nos. and reinforcement ring of cold twisted bar of 8 mm dia - 2800 mm (approx.) - 13 nos. at a spacing of 150mm, supplying & positioning fixing of 4 Nos 24mm diameter x 750mm long GI foundation bolts (EN8 Grade) with nuts, check nuts & washers including 2 Nos template of 4mm thickness of size 275mmx275mm with 4 Nos 28mm diameter holes to match with the PCD of the Pole Base Plate of foundation bolts, supplying & providing 2 m length 63 mm (O.D.) DWC HPDE pipe for cable entry and exit including excavation, centering & shuttering, refilling and disposing off extra excavated soil at suitable place etc. complete as required.

58

19554

1134132

... More
Suppling & erection of flanged type hot dip Galvanized (min. 65 micron) Octagonal Poles of 12 mtr. height made from 3mm thick HT Steel sheet having bottom dia of 210mm & top dia of 90mm with base plate of size 320mm x 320mm x 16mm thick complete with pole window at a height of aprox. 2 mtr. from the base having sleeve type window cover arrangement etc. on existing cement concrete pedestal as required including supplying and fixing of suitable size 6 mm thick phenolic laminated /backalite connection plate in the connection window with following accessories thereon i/c credit for old dismantle material as & where basis under buyback etc complete as reqd:- a) 60 Amp 4 Pole stud connector-1 No b) 6 amp. SP MCB 'C' Curve - 2 Nos c) Neutral Link- 1 No d) Earth Strip-1 No

15

42664

639960

... More
Installation of existing street light octagonal pole of length 10m/12m with bracket including shifting the pole from store to site by mechanicale means using hydra crane with proper safety, making cable connection etc complete as required.

43

3006

129258

... More
Designing, Fabrication, Supplying & Fixing of Galvanized street light pole bracket (single/double/tripple over hang) complete with pole cap, reducer, nut bolts etc. as per approved design on the existing street light pole of 10m / 12m height etc. complete as reqd.

225

313

70425

... More
Supplying & fixing of pole window cover made of 3 mm thick GI sheet of suitable size to suit the size of connection window of existing pole with sleeve type arrangement on the existing pole G.I. Street Light Pole i/c welding of sleeve around pole, suitable allen bolt etc complete as per direction of Engineer-in-charge.

48

1799

86352

... More
Painting of 10/12 m height GI/MS street light pole and mounting bracket with two or more coats of aluminium paint of approved brand & manufacturer to give an even shade, numbering of pole with yellow base and black (PWD logo & Pole number) and cost of paint in approved pattern including removing poster/stickers from the surface of the pole, cleaning & making good the surface for painting etc. complete as required.

48

2516

120768

... More
Providing and fixing 6 mm thick phenolic laminated/backelite sheet of suitable size inside the pole window including providing & fixing following accessories thereon, connection etc complete as required: a) 63 Amp 4 Pole stud connector-1 No b) 6 amp. SP MCB 'C' Curve - 2 Nos c) Neutral Link- 1 No d) Earth Strip-1 No

43

1450

62350

... More
Suppying and Drawing of 3 core 1.5 sq. mm PVC insulated overall PVC sheathed copper conductor flexible cable in the existing poles and brackets from cable termination connector to the fitting i/c connections etc. as reqd.

1044

125

130500

... More
Supplying, installation, testing & commissioning of 190-210 Watt IP-66 Street light LED fitting of following specification duly made of pressure die cast aluminum with toughened glass cover having LED as light source with secondary optic lens, suitable driver and other standared accessories, on the existing 10/ 12 mtr height street light pole with necessary reducer if required i/c connections, dismantling the existing fitting & credit for old fitting under buy back etc complete as reqd. System Lumen output : ≥ 24000 lm System Luminous efficacy: ≥ 120 lm/watt LED life: 50000 Hrs @ L-70 CCT: ≥ 5700k CRI: ≥70 Surge protection: ≥ 10 KV PF: ≥0.95 Driver Efficiency: ≥85% Operating Voltage: 160 to 270 Volt

136

21164

2878304

... More
Installation, testing & commissioning of existing outdoor type cubical street light Feeder Pillar of asorted size and fixing the same on MS angle iron frame of suitable size duly fabriceted with 50mm. x 50mm. x 6mm. (NS) having 4 nos 90 cm long legs out of which 45 cm duly grouted in cement concrete 1:2:4 (1 cement : 2 sand : 4 stone aggrete 20mm) i/c connections, interconnections etc complete as reqd.

1

8839

8839

... More
Supplying, Installation, testing & commissioning of outdoor type front openable double door compartmentalized cubical Feeder Pillar of suitable size & depth (minimum front area 1.4 sq. mtr. and depth not less than 30 cm) duly fabricated with 2 mm thick CRCA sheet steel with heavy duty locking arrangement, dust & varmin proof duly powder coated in approved shade complete with 4 strip aluminium bus bar of 200 Amp. capacity of high conductivity with DMC/ SMC bus bar supports, two nos. earth studs, MV danger notice plate etc. including supplying and fixing following switchgears & accessories therein, power & control wiring, connection, interconnections and fixing the same on MS angle iron frame of suitable size duly fabriceted with 50mm. x 50mm. x 6mm. (NS) having 4 nos 90 cm long legs out of which 45 cm duly grouted in cement concrete 1:2:4 (1 cement : 2 sand : 4 stone aggrete 20mm) i/c dismantling the existing wornout panel & credit for old panel under buy back, making good the damages etc complete as reqd. INCOMER: i) 1 No. 125 Amp, 25KA . 415 Volts TP MCCB ii) 3-Ph VAF + PF Meter with CT's-1 Set iii) RYB LED phase indication lamps with protection MCB's- 1 Set iv) 110 Amp. TP Power contactor AC-3 rating with NO NC aux contacts- 1 No. v) 24 Hr. digital Timer with Auto/Manual switch- 1 No. OUTGOINGS: i) 63 Amps 415 Volts TP MCCB of 16 KA (Ics = Icu = 100%)- 4 Nos.

1

158638

158638



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.