Public Works Department Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Public Works Department - PWD Tender
Eprocure
Opening Date30 Sep 2021
Closing Date7 Oct 2021
Tender Amount₹ 13,17,177
Costs
EMD
₹ 26,344Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_PWD_209053_1Bid Award Id
ViewTender No
52/EE(E)/NWED/PWD/2021-22Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://https://www.pwddelhi.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
b) 6 x 1.5 sq. mm
100
-
98
... More
c) 3 x 6 sq. mm
20
-
166
... More
d) 6 x 6 sq. mm
30
-
328
... More
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. a) 20 mm
120
-
129
... More
b) 25 mm
120
-
151
... More
c) 32 mm
30
-
203
... More
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
150
-
47
... More
Providing and fixing of PVC Trunking of following sizes complete with flexible cover, joint, endcap, cover on surface of wall/existing mounting etc. as required. a)105 mm x 50 mm
50
-
614
... More
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
180
-
375
... More
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
150
-
245
... More
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required
2
-
63
... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. a) 12 Module (200 mmX150 mm)
10
-
353
... More
b) 1 or 2 Module (75 mmX75 mm)
3
-
179
... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/ 6 A modular switch, connections etc. as required.
12
-
517
... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
60
-
416
... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
a) 15/16 A switch
40
-
117
... More
b) 6 pin 15/16 A socket outlet
40
-
157
... More
c) Bell push
1
-
117
... More
d) TV antenna socket outlet
1
-
99
... More
e) Telephone socket outlet
1
-
98
... More
Supplying, Laying and fixing of one number PVC insulated and PVC sheathed / XLPE Al armoured power cable of 1.1 KV grade of following size on wall surface/recess as required. a) size 3 X 10 sq. mm
100
-
114
... More
b) size 3 X 16 sq. mm
120
-
118
... More
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections , testing and commissioning etc. as required.
5
-
1005
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
a) 3 X 10 sq. mm (22mm)
6
-
175
... More
b) 3 X 16 sq. mm (25 mm)
14
-
207
... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
a) Upto 35 sq. mm (clamped with 1mm thick saddle)
250
-
26
... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a) 4 way (4 + 12), Double door
1
-
2254
... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a) 6 way, Double door
5
-
966
... More
b) 12 way, Double door
25
-
1181
... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) Single pole
158
-
177
... More
b) Single pole and neutral
25
-
456
... More
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing & commissioning etc. as reqd. a) 63 A
1
-
695
... More
Supplying & fixing of 300/305 mm sweep 1400 RPM 230 Volt 1-ph 50 Hz AC heavy duty Exhaust fan in the existing opening including making good the damage, connection, testing and commissioning etc. as reqd.
10
-
2189
... More
Supplying, Installation, testing and commissioning of prewired, 20 to 22 Watt, 1200 mm long LED Batten fitting with aluminium housing and integrated electronic driver wall mounted luminaire having the following specifications :i) Total System Power - Minimum 20 to 22 wattii) Color Temprature - 5700 K to 6500 Kiii) Power Factor - 0.95iv) CRI - 80,v) System Lumen Efficency - ≥100 LM/W,complete with all accessories etc. directly on ceiling / wall including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as reqd. (including dismantling the old fitting if any)
100
-
637
... More
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM,350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin,nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm,suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
58
-
2688
... More
Supplying, Installation, testing and commissioning of Recess mounted type Luminaries, glare free opal diffuser LED Panel of Nominal size 595 x 595 mm suitable for Armstrong / POP / GB ceiling with made out of CRCA Powder coated housing. Having the following specifications : i) Total System Power - 34 to 36 Watt,
ii) Color Temprature - 5700 K to 6500 K, iii) Power Factor - 0.95, iv) CRI - 80, v) System Lumen Efficency - ≥100 LM/W,complete with all accessories etc. directly on ceiling / wall including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as reqd. (including dismantling the old fitting if any)
50
-
3408
... More
Supplying, Installation, testing and commissioning of prewired 10 Watt to 12 watt LED Bulk head luminaire made out of extruded aluminium/CRC Sheet body with minimum lumens output 100 lumens per watt suitable for cool day white light having minimum CCT 5700K to 6500K, power factor 0.90, CRI 80%, complete with all accessories etc. including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
40
-
1159
... More
Supplying, installation, testing & commissioning of 100 to 110 watt energy efficient aluminium body, IP66 LED flood light fitting with lens & toughened glass capable of delivering following nominal system lumens output with a minimum system efficacy more than 110 lumens /watt and a CRI greater than 70 . The luminaire shall have a life class of 50000 hours @L70 for a design ambient of 35 deg C . The inbuilt electronic driver shall operate at power factor .95 of CCT 5700K minimum internal surge protection of 4 KV with toughened glass /polycarbonate cover LM 79/80 certification to be provided by the manufacturer for LED luminaire /LED chip .complete with all accessories i/c making connections, testing & suitable size bracket for fixing i/c dismantling the existing fitting etc. complete with all accessories etc. directly on ceiling / wall including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
12
-
7254
... More
Supplying and fixing hot press moulded SMC box (sintex) of following size i/c s/f SP MCB 02-32 Amps & neutral link on the existing pole /on the wall surface or recess repairing etc as reqd.a) 140mm x 140mm x 95mm
20
-
690
... More
SITC of 2.0 TR capacity energy efficient Hi-wall split type AC unit fitted with rotarary compressor dully filled ecofriendly refrigerant gas (R - 32 or better) having 5 STAR RATING (BEE star rating year 2021), Invertor Based Technology, nominal cooling capacity not less than 6300 watt and input power consumption not more than 2070 watt, suitable for operation on single phase, 220V, 50 Hz, AC supply i/c electronic remote control, comprising of both indoor and outdoor unit with copper condensor Coil, MS Angle iron stand for outdoor unit including 6 meter length, 4 core 2.5 sq.mm.wire, 4 mtr. copper tube of suitable size, wall thickness 0.8mm duly insulated with 9mm nitrile insulation, 5 mtr. PVC drain pipe of size 25mm i/c Elbow, Tee, Socket, Cement Solvent etc. complete as reqd.
3
-
54004
... More
Supplying & Fixing of 5 KVA capacity automatic voltage stablizer with time delay relay and high/low voltage trip facility input voltage 150 V to 270 V and output voltage 195 V to 245 Volt +10% with copper flexible cable connection etc. as required at site.
3
-
3974
... More
Supplying and fixing of 25 mm dia. size medium class PVC conduit/pipe along with accessories in surface/recess including cutting the wall and making good the same in case of recessed pipe for AC drain as required at site.
15
-
71
... More
Supplying and Fixing of refrigerant copper pipes of following sizes along with 1/2" Nylon Insulation tube complete with 3 core 2.5 sq.mm copper cable, clipping on wall surface i/c testing and commissioning etc. as reqd.
a) 3/8" & 5/8"
15
-
682
... More
Servicing/overhauling of existing cubical LT panel by removing all connection, cleaning of panels with blower, removing all idle connection, change of thimbles and nut bolts if required and reconnection, testing commissioning etc as required.
1
-
462