Public Works Department Tender

... More
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Public Works Department - PWD Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date21 Feb 2025
Closing Soon1 Mar 2025
Tender Amount₹ 35,85,102 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
SITC of mixing amplifier with following specification Rated output-300 Watt or better, Frequency range- ±3dB (50 to 15 kHz) distortion under 1% at 1kHz 1/3 rated power S/N ratio ˃ 760dB input 4 x Mic input, 2 x Aux inputs or better,Tone Control-Base, Treble:±8 dB at 100 Hz, Treble: ±8 dB at 10 kHzSpeaker output-4/8 Ω, 70/100 V, Barrier strip with cover

1

22321

22321

... More
Supply and Installation of Wall Mount speaker with following specification Enclosure 2-way bass-reflex type rated input-30 W @ 8 Ω Rated Impedance- 8 Ω/70 V/100 V Transformer Tap - 15 W /7.5 W Sound Pressure Level - 103 dB (1 W, 1 m) Frequency Response- 100 Hz - 19 kHz Speaker Component -3" Woofer & 1/2" Tweeter Speaker

10

9519

95190

... More
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.

-

-

-

... More
1 run of cable

150

34

5100

... More
2 run of cable

100

59

5900

... More
3 run of cable

50

84

4200

... More
Supplying and laying 2 core speaker cable with complete etc as reqd. at site.

150

14

2100

... More
SITC of 5,000 lumens WUXGA, 3LCD portable laser projector designed for long-lasting brightness having following specifications- Brightness- 5000 Lumens, Technology – Laser LCD Resolution- 1920 X 1200 Pixels, Contrast Ratio- 3000000:1, Multiple inputs.

1

134588

134588

... More
SITC of High Gain matte white fabric motorized screen etc complete as reqd.

1

17727

17727

... More
Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5

14

16415

229810

... More
Supply, installation, testing and commissioning of following minimum capacity4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unite quipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cordless mote control etc., suitable for operation on single phase 230V±10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at airinlet conditions of 27Degree CD Band 19 Degree C WB temperature. 2.8 TR

4

32015

128060

... More
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :

-

-

-

... More
9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation

90

331

29790

... More
15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation

90

588

52920

... More
Supplying & Fixing 25 mm dia drain pipe CPVC with tee, Bend, elbow complete etc as reqd.

100

113

11360



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.