Netaji Subhas Institute Of Technology Tender

If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Netaji Subhas Institute Of Technology - NSIT Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date12 Sep 2024
Closing DateCancelled
Tender Amount₹ 3,45,44,152 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
3 Stone (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete. a) 18 mm thick Granite of any colour and shade

28

125299

4474.98

... More
4 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade a) Area of Slab upto 0.50 sqm

4

21654

5413.5

... More
b) Area of slab over 0.50 sqm

8

41090

5136.3

... More
5 Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work

165

84306

510.95

... More
6 Providing and fixing factory made uPVC glazed /wire mesh windows/ door comprising of lead free uPVC multi- chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70mm for series R1 and R2 profiles and 2.10mm for Series R3 and R4 profiles conforming to EN : 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8mm dia with countersunk head, comprising of matching polyamid PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded / mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification and direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-charge. Wire mesh/ Glazing of plain/ toughened / laminated double glass unit with / without high performance coating as per design requirements and conforming to IS : 3548 & IS : 16231 shall be paid separately. Note: Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for : i) Sites with basic wind speed 45 m / sec as per IS 875- Part 3. ii) Sites with structure height more than 20m for all wind speeds a) Fixed window/ ventilator without mullion/ transom. Using R1 series with frame (33mm & above) x (35mm & above) (Height upto 0.90 meters)

3

24741

8247.25

... More
b) Fixed window/ ventilator without mullion/ transom. Using R3 series with frame (55mm & above) x (45mm & above) (Height upto 2.5 meters)

28

198241

7080.05

... More
7 Providing and fixing factory made uPVC glazed /wire mesh windows/ door comprising of lead free uPVC multi- chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70mm for series R1 and R2 profiles and 2.10mm for Series R3 and R4 profiles conforming to EN : 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8mm dia with countersunk head, comprising of matching polyamid PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded / mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification and direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-charge. Wire mesh/ Glazing of plain/ toughened / laminated double glass unit with / without high performance coating as per design requirements and conforming to IS : 3548 & IS : 16231 shall be paid separately. Note: Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for : i) Sites with basic wind speed 45 m / sec as per IS 875- Part 3. ii) Sites with structure height more than 20m for all wind speeds Casement window single panel with SS 304 friction hinges as per size and weight of sash, multi - point locking system, zinc alloy (zamak) powder coated handles. Using R3 series with frame (55mm & above) x (45 mm & above) & sash (55 mm & above) x (65 mm & above) (Height upto 1.8 metre )

13

174032

13387.15

... More
8 Providing and fixing factory made uPVC glazed /wire mesh windows/ door comprising of lead free uPVC multi- chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70mm for series R1 and R2 profiles and 2.10mm for Series R3 and R4 profiles conforming to EN : 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8mm dia with countersunk head, comprising of matching polyamid PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded / mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification and direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-charge. Wire mesh/ Glazing of plain/ toughened / laminated double glass unit with / without high performance coating as per design requirements and conforming to IS : 3548 & IS : 16231 shall be paid separately. Note: Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for : i) Sites with basic wind speed 45 m / sec as per IS 875- Part 3. ii) Sites with structure height more than 20m for all wind speeds Using R3 series with frame (55 mm & above) x ( 40mm & above) & sash (30 mm & above) x (55mm & above) with zinc alloy (zamak) power coated handle on every panel along with multi point locking system (Height upto 1.8m)

8

70394

8799.25

... More
9 Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. all complete as per the directions of Engineer-in-charge a) 10x60mm

27

3539

131.1

... More
10 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent

279

1250282

4481.3

... More
11 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)

25

8676

347.05

... More
12 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 fine sand)

25

9986

399.45

... More
13 Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound) content less than 50 gms/litre, of approved brand and manufacturer including applying additional coats whereever required to achieve even shade and colour. old work (one or more coats)

185

11599

62.7

... More
14 Applying priming coat with primer of approved brand and manufacture having low VOC (Volatile Organic Compound) content : with water thinable cement primer on wall surface having VOC content less than 50 grams/ litre

185

13680

73.95

... More
15 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

185

28869

156.05

... More
16 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar

6

12361

2060.2

... More
17 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.

185

4652

25.15

... More
18 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below a) Of area 3 sq. metres and below

40

14688

367.2

... More
b) Of area beyond 3 sq. Metres

8

4022

502.75

... More
19 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of material to MCD approved dumping ground for all leads and lifts. All complete as per the directions of Engineer- in- charge.

116

6339

54.65

... More
20 Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of material to MCD approved dumping ground for all leads and lifts. All complete as per the directions of Engineer- in- charge.

4

14205

3551.25

... More
21 Dismantling tile work in floors and roofs laid in cement mortar including disposal of material to MCD approved dumping ground for all leads and lifts. All complete as per the directions of Engineer- in- charge. For thickness of tiles 10 mm to 25 mm

364

26717

73.4

... More
22 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints all complete as per the directions of Engineer in Charge. Internal work -Exposed on wall a) 20 mm nominal dia Pipes

50

16750

335

... More
b) 25 mm nominal outer dia Pipes

37

14857

401.55

... More
c) 32 mm nominal outer dia Pipes

25

12968

518.75

... More
d) 40 mm nominal dia Pipes

25

17573

702.95

... More
23 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints all complete as per the directions of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. a) 20 mm nominal outer dia Pipes

40

21504

537.6

... More
b) 25 mm nominal outer dia Pipes

40

25090

627.25

... More
24 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling & testing of joints complete as per direction of Engineer in Charge. External work a) 32 mm nominal dia Pipes

10

4386

438.6

... More
b) 40 mm nominal outer dia Pipes

10

5630

563.05

... More
25 Filling the gap in between aluminium frame & adjacent RCC/ Brick/Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.Upto 5mm depth and 5 mm width

109

10545

96.75

... More
26 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer in-charge. Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side

12

13671

1139.3

... More
27 Providing and fixing toughened double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete

38

189912

4997.7

... More
28 Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987,Non combustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter locking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm)i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-ChargeWith semi perforated 12 mm thick micro tegular edged GRG false ceiling tiles.

419

776008

1852.05

... More
29 Providing and placing factory made Modular laboratory Table of size 7130mmLX1500mmDX900mmHt with Storage comprising of the following. ------------------ Electrical fittings A)6/16A, 6 Pin Shutter Socket - Model No: M1332 with 32nos B)6 Module Plate - Model No: Cs956M-S with 16nos C)16A, 1 Way Switch Model No: M0130 with 32nos D)Master Upright Extension-( 300W X 150D X 600H ) with 1nos

4

6015312

1503828

... More
30 Providing and placing factory made Modular laboratory Table of size 5180mmLX1500mmDX900mmHt with Storage comprising of the following. ----------- Electrical fittings A)6/16A, 6 Pin Shutter Socket - Model No: M1332 with 16 nos B)6 Module Plate - Model No: Cs956M-S with 8nos C)16A, 1 Way Switch Model No: M0130 with 16nos D)Master Upright Extension-( 300W X 150D X 600H ) with 1nos

4

4409288

1102322

... More
31 Providing and placing factory made Modular laboratory Table of size 3000mmLX750mmDX900mmHt with Storage comprising of the following. --- Electrical fittings A)1350 Module Length Single Side Electrical Trunking - Cutouts: 6 Module + 6 Module + 6 Module with 2nos B)6/16A, 6 Pin Shutter Socket - Model No: M1332 with 12nos C)6 Module Plate - Model No: Cs956M-S with 6nos D)16A, 1 Way Switch Model No: M0130 with 12nos E)Outer Cover For Single-Sided Electrical Trunking with 2nos

3

645488

215162.88

... More
32 Providing and placing factory made Modular laboratory Table of size 1580mmLX750mmDX750mmHt with Storage comprising of the following -------- Electrical fittings A)1500 Module Length Single Side Electrical Trunking - Cutouts: 6 Module + 6 Module + 6 Module with 1nos B)6/16A, 6 Pin Shutter Socket - Model No: M1332 6nos C)6 Module Plate - Model No: Cs956M-S with 3nos D)16A, 1 Way Switch Model No: M0130 with 6nos E)Outer Cover For Single-Sided Electrical Trunking with 2nos

3

339957

113319.12

... More
33 Providing and fixing Emergency Shower etc as per direction of Engineer-In-Charge. FLOOR BASED PVC EMERGENCY SHOWER CUM EYE-WASH – Corrosion resistant, combination eye wash/shower safety station with ABS plastic shower head, ABS plastic bowl, cast aluminum powder coated flag handle, PVC floor flange, 2” IPS Schedule 80 PVC pipe and fittings, 1” IPS and ½” IPS U.S. made PVC coated brass stay open ball valves, and polished stainless steel pull rod. Unit shall have (2) polypropylene spray heads with integral dust covers, filters, and 1.8-GPM flow control orifices mounted on a PVC coated brass head assembly. Unit shall include ANSI compliant sign Ss Emergency Safety Shower With Eye / Face Wash Complete Ss Construction with 1nos

3

314259

104753

... More
34 Providing and fixing Chemical storage etc as per direction of Engineer-In-Charge. It is used for storages of corrosive chemicals and is provided with a ventilation system to enable exhaust of localized fumes emanating from the chemicals stored. The material should be is 1.2 mm CRCA MS with pure Epoxy Powder coating. It must be fitted with a float glass to enable visibility inside the cabinet. It should also has louvers/perforations for air supply. The overall dimensions are 1000 x 486 x 1800 mm (W x D x H) a)Chemical PP storage 1000W x 1500H x 486D

3

487503

162501.29

... More
b)Pp Damper Dia 230 Mm X 150 Mm 6 Mm Thickness

3

20799

6933.07

... More
c)Flexible/F Serated Connector Model : Hp 01 Make: Premier

3

2130

710.07

... More
d)Anti-Siphon Bottle Trap Model : S 04 Make: Premier

3

2060

686.9

... More
35 Providing & fixing Wall mounted storage cabinet with two shutter in 600mm width, 340 depth and 635 height. The construction should be the same as the under-bench cabinets. The height of these cabinets should be around 635mm while the depth should be around 340mm. The shutters should be available in two options: Metal shutters and Metal frame with inserted glass. There should be one height-adjustable shelf inside each cabinet. Other construction should be similar to under-bench cabinet Over Head Storage with the size of 600mm W, 340mm D and 635mm H WT-2S-GS-600W-635H

18

416973

23165.21

... More
36 Providing and fixing Spot extractor etc as per direction of Engineer-In-Charge. General description - Extractor arms mainly for use in chemical environments, where an extended resistance against chemical substances is a demand. All aluminium parts should have a double anodized surface protection Arm sections – Thin walled anodized aluminium sections with a very good corrosion resistance. Swivel – Swivel with 360 degree rotation. Add reduction for correct connection diameter. Joints – The adjustment knobs on the friction joints should be supported by ball-bearings. The first joint should be supported by a spring. ( dia should be 75 mm, length of the spot extractor office ceiling mounting bracketshould be 1500 mm) 360 degree rotation where indicated. Mini hood – The Mini hood should be supplied together with the arm and is also interface to the multi-purpose and metal hood. Mounting – The arms can be mounted on ceilings, walls and floors or fixed to tables. By using an extension profile the arm’s operational reach must be increased. Other – All the arms should be provided with dampers, tight down to an under pressure of 3500 Pa. Air temperature -10 ̊C to 70 ̊C. Material recovery: 99% by weight. Components to be provided: Spot Extractor arm, Bracket for Spot Fume Extractor, Multi-purpose hood (380mm x 460mm), Aluminium Extension Profile 1100mm Length, Reducer 75-80 FR Spot Fume. SPOT EXTRACTOR (Fumex) Ceiling/ Wall Mounted MET 1500-75PP/MEK350-75PP/MTICT/ MTI1700

36

7469122

207475.63

... More
37 Providing and fixing Benchtopfumehood 4 feet width etc as per direction of Engineer-In-Charge. BenchtopFumehood of (4 feet): Overall dimension of 1200x 900 x 2400, Working Volume 920x665x1180. Superstructure Frame: It shall be a free-standing rigid panel structure of steel (G.I.) Interior Walls: Double wall ends, not more than 6” wide, shall be provided to maximize interior working area. The area between the double wall ends shall be closed to house the remote control valves. Cut-outs shall be provided inside the fume hood for service line accessibility. The same to have a cover with a fastener free design. The vertical fascias shall contain the required service controls, electrical switches and receptacles. ----- LED LIGHT: Two LED Lights of Philips or equivalent make shall be provided in the fume hood. The lighting fixture shall be completely outside the fume hood area. The luminosity on the work surface shall be average 600 Lux. Fume hoods are designed to rest on pedestal or a cabinet which is a complete rigid steel structure. Gauge of steel used in its construction shall be 0.8 mm GI for apparatus storages, FIXED TYPE APPARATUS STORAGE CABINET FOR BENCH TOP FUME HOOD (600 WIDTH) and Rear Support Panel Offixed Type Apparatus Storage Cabinet For BenchtopFumehood, Ceiling Front Cover Panel For 4 Feet Fumehood and Ceiling LH/ RH Side Cover Panel For Fumehood

5

2805719

561143.88

... More
38 Providing and fixing Blower with complete accessories etc as per direction of Engineer-In-Charge. A) Centrifugal Fan with Housing in PP Construction & suitable stand in MS Zinc Plating with Powder Coating. Inlet/Outlet Dia: 400mm Impeller Dia: 400mm Non FLP Motor: 3 HP 1400 RPM CFM: 2600 @ 50 WCMM Static Pressure Motor make : IE2 (Non FLP), Crompton Greaves/Bharat Bijlee make whichever is available DB Level: 85 Approx Motor Description: IP55, 3 Phase, 440 Volt , 50 Hz. Weather cover for motor of model For PP40 Model Anti-Vibration Pads & M10x100 pin type Anchor Fasteners Blower Weather Cowl (FRP Outlet) & MS Stack Support with required Clamps PP40-3014 Anti-Vibration Pads & M10x100 pin type Anchor Fasteners

5

900022

180004.57

... More
39 Providing and fixing Exhaust Ducting with complete accessories etc as per direction of Engineer-In-Charge. a) Design, supply & Installation of PP-FRP ducting of wall thickness 3mm PPGL + 3mm FRP for sizes up to 500mm Dia, Above 501mm Dia 4mm PPGL + 4 mm FRP shall be used unless otherwise specified. Including clamps, hanging support, all hardwares required to complete ducting work. b) PP FRP Ducting of 3mm+3mm

2010

2387880

1188

... More
40 Providing and fixing Faculty chair for lab etc as per direction of Engineer-In-Charge. The overall dimensions of the chair shall be 76.1cm x 76.1cm x (113.6-131.1cm). The seat height shall be 44.5cm-54.5cm. The cushioned seat and back is made of injection moulded Plastic outer and Inner. Plaster inner is upholstered with stitched cover and moulded high Resilience Polyurethane foam of density 45kg per meter cube. The stitched cover is made from spacer fabric and leatherette. Seat size shall be 47cm x 48cm. The Back size shall be 45cm x 75.5cm. The armrests top is moulded from PU and mounted on to a drop lift adjustment type tubular armrest support made of 3.8cm diameter x 0.2cm thick MS ERW tube. The armrest height is adjustable uptp 6.5cm in 5 steps. The armrest structure is powder coated upto 40-60 microns. It shall have active bio synchro mechanism with features like 360 degree revolving, front pivot tilt mechanism, tilt tension adjustment, 5-position tilt limiter, etc.. Seat depth adjustment is integrated in the seat through a sliding mechanism. Seat depth adjustment range is 6cm. It shall also have adjustable back support. Back frame is connected to Up/Down mechanism housed in plastic T spine. It can be adjusted fro 7.2cm for comfortable back support to suit individual need. The pneumatic height adjustment has an stroke of 10cm. The pedestal is injection moulded in black 33 % glass filled Nylon 66 and fitted with 5 nos. of twin wheel castors. The pedestal is 66cm pitch center dia.

3

54669

18223

... More
41 a) Providing and fixing Locker Unit for students etc as per direction of Engineer-In-Charge. Product Size: 375(W) × 470(D) × 1950*(H),Height including leveler, Height of leveler is 50mm and adjustment possible is 15mm. Contruction of Material: Aesthetically appealing completely knock down • construction. The add-on units are stack widthwise to form a row of Lockers. (Note- Single Main unit should not be offered. Minimum 1Main + lAddon to be offered Maximum 1Main + 4Addon to be offered) Legs fitted with screw type leveler. • Made from combination of Top panel(0.5mm CRCA), side panel(0.5mm (RCA), Bottor panel(0.5mm CRCA). Back panel{0.5mm CRCAM stiffener(1.2mm CRCA) and End Covert0.5mm CRCA\ - CRCA 'D' Grade as per IS-513. Made from 0.6mm Thick CRCA (D Grade, IS-513) Soft closing hinge. Door has envelope slot with cover made of plastic with label paper. Door size For 6 Door locker - 373(W) × 18(T) × 314 (H). It is a 10 bend panel made of 0.5mm Thick CROA (D Grade, 15-513) Uniformly distributed load capacity of each shelf is 20kg 5 Shelves for 6 Door locker with and without envelope slot.

27

524691

19433

... More
b) Providing and fixing Lab Stool for students etc as per direction of Engineer-In-Charge. The seat shall be made up of 1.2±0.1cm thick flat plywood measured as per QA method described in OCP-QLTA-P14-18 and with moulded Polyurethane foam and are upholstered with replaceable synthetic leather covers. The dimensions of Seat shall be Diameter 40.0 cm and Adjustments are 360° Revolving type. The back foam shall be designed with contoured Lumbar support for extra comfort. The upholstery shall be available in synthetic leather. The dimensions of Back shall be 45.0 cm (W) covered with polyurethane foam. The HR polyurethane Foam shall be moulded with density = 45 +/-2 kg/m3 and Hardness load 16 ± 2 kgf as per IS:7888 for 25% compression. The manual height adjustment shall be very easy to operate with a help of a knob. It should be easily locked at the most comfortable position. The five-prong pedestal shall be fabricated from 0.2 ± 0.02 cm thick HR sheet ( IS : DD 1079/HR ), powder coated ( DFT 40-60 microns ) and shall be fitted with an injection moulded black Polypropylene Hub Cap and 5 nos. twin wheel castors. The Pedestal shall be 55.0±0.5cm pitch-circle-diameter(65.0±-1.0cm with castors), Circular-foot-ring of dia 52.0±0.2cm shall be made up of dia 1.9±0.2 x 0.12±0.0096cm thk MS ERW Tube for foot support in High-base stool.The twin wheel castors shall be injection moulded in Black Nylon. Overall dimensions shall be Width- 65.0cm, Depth- 65.0 cm, Height- 88.0 to 99.5 cm, Seat Height- 67.0 to 78.5 cm. Company should be ISO-9001, 14001, 45001, 50001, Greenguard, BIFMA, and AIOTA certified. Product should be BIFMA LEVEL-2 and Greenguard (UL) certified.

70

454790

6497

... More
42 Providing and fixing Faculty Table etc as per direction of Engineer-In-Charge. Supplying and Placing in position Faculty Table of following Specifications. Overall Dimension of the Main Desk Shall be - 1500mm x 600mm The system shall be a desk-based system with a platform understructure made up of a combination of MS. Tubes and plates. The product should be Greenpro certified and should be listed in Griha product catalogue in the following category GRIHA V.3 criteria: 34; GRIHA V.2015 criteria: 31 & SVAGRIHA criteria: 14. Understructure - The slanted legs are connected to the understructure with the help of PDC Connectors to provide a stable and sturdy base for the worktops. Modesty panel shall be of Acrylic (8 mm thick Acrylic both side frosted) or of Metal 1.2 mm thick CRCA. Worktop - Worktop shall be made of 25MM thick Pre-Laminated Board conforming to IS: 12823. All the edges of work surface shall be provided with machine pressed 2 mm thick PVC lipping glued with hot melt EVA glue. The worktop shall be complete with provisions for screen mounting as well as for wire management on the workstation. Provisions for fixing of the switches shall be on the wire tray/channel. A Wire Management - It shall be a part of the understructure and can be in the form of enclosed metal tray or 2 level enclosed channel to provide concealed wire management throughout the cluster formation. Wire riser leg or independent wire risers shall be provided as per the layout structure.ccess flaps with soft closing technology shall be provided on the table tops to access the switch points on the tray. Pedestal having 3 Drawers Unit having flat metal front and top with Central locking. The Drawer Unit consists of 2Box and 1File Drawers. The Overall size of the Drawer Units is 450mm(W) X 435mm(D) X 646mm(H). Construction & Material of Drawer Unit :Welded Assembled of 0.8mm thick CRCA for Body Shell, Drawer Front & tray, Front Side Stiffener, Rear Side Stiffener & Bottom, 1.2mm thick CRCA Top Stiffene, Bottom stiffener, Drawer Fronts & Metal Front Straight Edge. All Drawers with Double extension precision ball slide shall be provided. For Drawer pulling, side wise tapered recess provided in shell behind Drawer Fronts. Locking:10 lever Cam Lock & Central RH locking with actuator & lock channel mechanism. Top Panel : 0.8mm thick Metal Straight Edge Top. Castors : Swiveling non-lockable 4Nos Castors mounted below the body shell. The Total drawer unit is finished with Epoxy Polyester Powder coated to the thickness of 50 microns (+/-10). The product should be complete and as per approved sample and as per the direction of Engineer-In-charge.

3

130542

43514

... More
43 Providing and fixing manual chain operated roller blinds consisting of 100% Polyester fabric, fabric thickness 0.50 mm, fabric weight = 270 gsm ± 5%, fabric width 230 cms, tearing strength 4.5 kgf warp, bursting strength 34 kgf, colour fastness to light 5 to 6 grade in position of standard quality and approved shade/colour including necessary accessories, MS clamps, screws and drilling etc. as required all complete as per the directions of Engineer-in-charge

35

50513

1443.25

... More
44 Installation and Supply of 15 mm IS1239 Grade MS C Class heavy pipe. with all accessories BEND, TEE, REDUCER etc all complete as per direction of Engineer-In-Charge.

15

5841

389.4

... More
45 Installation and Supply of 25 mm IS1239 Grade MS C Class heavy pipe. with all accessories BEND, TEE, REDUCER etc all complete as per direction of Engineer-In-Charge.

96

74764

778.8

... More
46 Installation and Supply of 40 mm IS1239 Grade MS C Class heavy pipe. with all accessories BEND, TEE, REDUCER etc all complete as per direction of Engineer-In-Charge.

39

40497

1038.4

... More
47 Supply & Installation of Ball Valves IGL approved. (25mm) etc all complete as per direction of Engineer-In-Charge.

12

48852

4071

... More
48 Supply & Installation of Ball Valves IGL approved. 40 mm etc all complete as per direction of Engineer-In-Charge.

3

19470

6490

... More
49 Third Party Inspection Charges for Room No. 318, 319 & 320.

3

88500

29500

... More
50 Supply and Installation of pressure gauge with isolation valve - 4 kg i/c calibration certificate etc all complete as per direction of Engineer-In-Charge.

3

4425

1475

... More
51 Supply and Installation of Lab burners with safety mesh and flexible pipe etc all complete as per direction of Engineer-In-Charge..

60

22302

371.7

... More
52 Supply and Installation of Brass Tap Valve for Burners etc all complete as per direction of Engineer-In-Charge.

60

14160

236

... More
53 Supply and Installation of 2 way terminal block etc all complete as per direction of Engineer-In-Charge.

60

31152

519.2

... More
54 SITC Gas leak detector CRIM OR CCEEO approved etc all complete as per direction of Engineer-In-Charge.

30

354000

11800

... More
55 SITC Control multiple panel 12 zone 24v dc etc all complete as per direction of Engineer-In-Charge.

3

87296

29098.8

... More
56 SITC 25 mm Solenoid valve 240v dc etc all complete as per direction of Engineer-In-Charge.

3

34656

11552.2

... More
57 SITC Industrial Hooter siren etc all complete as per direction of Engineer-In-Charge.

3

3398

1132.8

... More
58 Providing and fixing 3 core wire isi mark including conduit pipe or pvc pipe etc all complete as per direction of Engineer-In-Charge.

300

84960

283.2

... More
59 SITC 25mm union set for solenoid valve etc all complete as per direction of Engineer-In-Charge.

3

2035

678.5

... More
60 Providing and fixing 18 mm thick edge moulded granite 60 mm to 80 mm wide over the wall lining including machine polishing to edge to give high glass finish etc. all complete as per the approved design and directions of Engineer-in-charge.

97

58223

600.24

... More
61 Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge.

141

7945

56.35

... More
62 Deduct on account of issue of old doors etc. to the contractor as buy-back material.

4

-1600

400

... More
63 Deduct on account of issue of existing false ceiling system to the contractor as buy-back material.

141

-42300

300

... More
64 Deduct on account of issue of old MS Grill, MS Angle etc. to the contractor as buy back material.

350

-12950

37

... More
65 Deduct on account of issue of Aluminium Sections etc. to the contractor as buy back material.

210

-40110

191

... More
B- ELECTRICAL 66 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 66.1 Group C

66

96822

1467

... More
67 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. 67.1 Group C

30

25740

858

... More
68 Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin , 15/16 Amps modular socket outlet and 15/16 Amps modular switch , connection etc . as required .

24

14064

586

... More
69 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.

250

83500

334

... More
70 Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.

1000

537000

537

... More
71 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit asrequired. 71.1 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

110

30250

275

... More
72 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel conduit as required ( For computer power in Furniture ) 72.1 3 x 4 sqmm

330

67980

206

... More
72.2 6 x 4 sq. Mm

360

142560

396

... More
73 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 73.1 6 Module

6

1092

182

... More
73.2 12 Module

6

1632

272

... More
74 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar,din bar for mounting MCCBs (but without MCCBs and incomer ) as required . (Note : Vertical type MCCB TPDB is normally used where 3 phase outlets are required.) 74.1 12 way (4 + 36), Double door

2

25666

12833

... More
75 Supplying and fixing 5 amps to 32 amps, rating, 240/415 volts, 'C' Curve , miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 75.1 Triple pole and neutral

24

29472

1228

... More
76 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 76.1 100 A, 16 KA,TPMCCB

2

7554

3777

... More
76.2 100 A,30KA,FPMCCB

2

15446

7723

... More
77 Providing and fixing following rating and 4 pole MCCB box Size I suitable up to 125A MCCBs, 36kA with terminal spreaders, making connections, etc. as required.

2

4904

2452.01

... More
78 Dismantling the existing worn out / defective fittings from the ceiling and SITC of minimum 36 watt ultra slim energy efficient LED Panel light fitting having aluminium body system efficacy minimum 100 lumen/watt LM79, color temp 6500 deg K, recess mounting suitable for fitting in the 600mm x 600mm square existing space having symmetric glare free illumination in the false ceiling complete with all standard accessories including drivers, dash fastener & chain connection etc. complete as required.

60

229596

3826.61

... More
79 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.

36

98280

2730

... More
80 Supply of one number XLPE insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size complete as required. 80.1 4C x 50 sqmm Aluminium armoured cable

230

173751

755.44

... More
81 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 81.1 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

230

29900

130

... More
82 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.

460

32200

70

... More
83 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 83.1 4 X 50 sq. mm (35mm)

8

3344

418

... More
84 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

4

29888

7472

... More
85 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

180

43920

244

... More
86 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.

12

8472

706

... More
87 Supply and installation of corrosion proof GI (hot dip galvanized) raceways made out of 1.6mm thick sheet steel, standard length 2.5 meters, 1/2/3 compartments top and bottom double folded and spot welded together to give required rigidity and prevent seepage of concrete or screed water complete with cover jointing sleeves and other accessories. 87.1 225x38x1.6x2 -3Comp 2.5Mtr

80

395791

4947.39

... More
88 Supply and Installation of Pre-galvanised sheet steel Junction boxes of following sizes having one piece base frame design, trap covers made up of 2mm thick pre-galvanised sheet steel having 8 mm recess for installation of Tiles, having Stainless steel screws for trap covers, brass terminals for earth connection and load bearing capacity of upto 3.6 metric ton.(HSN Item Code ESB 250 ML) 88.1 250 x 250 x 60 mm

20

227154

11357.7

... More
89 Supplying and fixing of UPVC trunking of size 100 x 50 along with accessories on surface complete as required.

20

19680

984

... More
90 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface / recessed steel / PVC Conduit as required. 1 Run of Cable (Make:- CommscopeSystimax Only)

120

6840

57

... More
91 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 91.1 RJ 45 Information Outlet

3

3171

1057.05

... More
92 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 92.1 1 or 2 Module

3

399

133

... More
93 Providing and fixing Stranded Low smoke Halogen Cordage Unshielded Cat 6 Modular Patch cord of length 1 mtr with plug insertion life not less than 750 times and minimum Plug Retention force of 133N i/c making connections etc. complete as required.

3

2650

883.65

... More
94 Providing and fixing Stranded Low smoke Halogen Cordage Unshielded Cat 6 Modular Patch cord of length 2 mtr with plug insertion life not less than 750 times and minimum Plug Retention force of 133N i/c making connections etc. complete as required.

3

3542

1180.77

... More
95 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 95.1 25 mm

120

17400

145

... More
96 Dismantling & Buy Back of old & defective following items from NSUT as per required. (Contractor / Agency should be ensure that disposal of the old / defective wastage material should be disposed off through the autorised recycler registerd under Delhi Pollution Central Board / Central Pollution Control Board. Contractor/ Agency should also submit 'Certificate of Destruction'). 96.1 Light fitting.

48

-4800

100

... More
96.2 Ceiling Fan

36

-18000

500



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.