Netaji Subhas Institute Of Technology Tender
If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.
Costs
EMD
₹ 4,07,712Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_NSIT_233748_1Bid Award Id
ViewTender No
NIT No.53/VC/2022-23/NSUTTender Authority
Netaji Subhas Institute Of Technology ViewPurchaser Address
-Website
http://http://www.nsit.ac.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
2.3 2.6 TR
1
-
42350
... More
2.4 2.8 TR
2
-
46782
... More
2.5 3.4 TR
1
-
47651
... More
2.6 4 TR High Static Ductable units (minimum 110 pascal external static pressure)
1
-
48731
... More
2.7 5.5 TR
7
-
85766
... More
2.8 7.1 TR
14
-
87281
... More
2.9 8 TR
11
-
89590
... More
3 Supply, installation, testing and commissioning of following minimum capacity VRV/VRF High wall type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cordless remote control, drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.
3.1 2 TR
6
-
22100
... More
4 Supply, Installation, testing & commissioning of Y Joints for IDU's
76
-
3924
... More
5 Supply, Installation, Testing & commissioning of Central Remote Controller for controlling the all IDU's & ODU's
4
-
24182
... More
6 Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometricnitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :
6.1 41.27mmdia(OD)(Harddrawn)withtubethickness1.62mmwith19mm thick insulation
36
-
1309
... More
6.2 38.1mmdia(OD)(Harddrawn)withtubethickness1.62mmwith19mm thick insulation
32
-
1265
... More
6.3 34.9 mm O.D. (Hard drawn)with tube thickness 1.62mm with 19 mm thick insulation
109
-
1230
... More
6.4 31.8mmdia(OD)(Harddrawn)withtubethickness1.62mmwith19mm thick insulation
75
-
1170
... More
6.5 28.58 mm O.D. (Hard drawn)with tube thickness 1.2mm with 19 mm thick insulation
64
-
1108
... More
6.6 25.4mmdia(OD)(Harddrawn)withtubethickness1.2mmwith19mm thick insulation
23
-
1022
... More
6.7 22.2 mm O.D. (Hard drawn)with tube thickness 1.2mm with 19 mm thick insulation
71
-
865
... More
6.8 19 mm O.D. (Hard drawn)with tube thickness 1.2mm with 19 mm thick insulation
140
-
707
... More
6.9 15.86 mm O.D. (Soft drawn)with tube thickness 1.2mm with 19 mm thick insulation
97
-
588
... More
6.10 12.7 mm O.D. (Soft drawn)with tube thickness 1.2mm with 19 mm thick insulation
70
-
466
... More
6.11 9.5 mm O.D. (Soft drawn)with tube thickness 1.2mm with 19 mm thick insulation
20
-
331
... More
6.12 6.4mmdia(OD)(Softdrawn)withtubethickness1.2mm with19 mm thick insulation
20
-
245
... More
7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
7.1 25 mm
160
-
408.55
... More
7.2 32 mm
300
-
500.95
... More
7.3 40 mm
110
-
674.35
... More
8 Supplying, laying, fixing, testing and commissioning of following thickness closed cell elastrometric nitrile rubber of class '1' applied by suiatable adhesive, as per specifications and as required complete in all respect.
8.1 Insulation with nitrile rubber of thickness 9 mm on existing pipe.(insulation on 25,32 mm dia cpvc pipe).
250
-
387
... More
9 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
9.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
500
-
233
... More
10 Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.
10.1 Thickness 0.60/0.63 mm sheet
1200
-
1058
... More
10.2 Thickness 0.80 mm sheet
500
-
1229
... More
11 Supplying, laying, fixing, testing and commissioning of following thickness closed cell elastrometric nitrile rubber of class 'O' applied by suiatable adhesive, as per specifications and as required complete in all respect.
11.1 19mm
1700
-
665
... More
12 Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
25
-
9105
... More
13 Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.
25
-
5910
... More
14 Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core.
2
-
12184
... More
15 Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications.
50
-
708
... More
16 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
16.1 300 mm width X 50 mm depth X 1.6 mm thickness
500
-
963
... More
SH-02 (CABLING) 17 Supply of XLPE insulated Copper conductor, Copper armoured 1.1 KV grade cable of following size complete as required.
17.1 3C x 1.5sqmm
1150
-
175.28
... More
17.2 4C x 10sqmm
260
-
944.3
... More
17.3 4C x 16sqmm
400
-
1382.95
... More
17.4 4C x 25sqmm
200
-
2265.77
... More
18 Supplying of one number Aluminium armoured XLPE power cable of 1.1 KV grade of following size complete as required.
18.1 4C x 95sqmm
140
-
1170.97
... More
18.2 4C x 120sqmm
70
-
1440.77
... More
18.3 4C x 400 Sqmm
110
-
4416.82
... More
19 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray/wall as required.
19.1 Upto 35 sq. mm (clamped with 1mm thick saddle).
1960
-
45
... More
20 Laying and fixing of one number PVC insulated and PV Csheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
20.1 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp).
135
-
130
... More
20.2 Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp).
65
-
153
... More
20.3 Above 185 sq. mm and upto 400 sq. mm (clamped with40x3mm MS flat clamp).
60
-
226
... More
21 Cutting holes of required size in brick masonry wall for passing of copper pipes, Drain pipes, cable removing of false ceiling and re-fixing/placing back if required etc. and making good the same etc. complete as per direction of Engineer-in-charge.(The hole shall be made by core cutter).
30
-
300
... More
SH-03 (MAIN LT PANEL & DISTRIBUTION BOARD) 22 Supplying, Installation, Testing and Commissioning of cubical type outdoor LT panel suitable for 415 V, 3 phase, 4 Wire 50 Hz AC supply system fabricated in compartmentalized (preferably) design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process from powder coating in approved shade, having 800Amps. capacity extensible type TPN aluminium alloy bus bars of high conductivity, DMC / SMC bus bars of high conductivity, DMC / SMC bus bars supports, with short circuit withstand capacity of 31 MVA for 1 Sec. bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 nos. earth stud. solid connections from main bus bas to switch gears with required size of Al. bus bars and control wiring with 2.5sq mm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c. providing switch gears: - (Panel shall be TTA approved) (Including voltmeter, ammeter, indication lamp, CT, setector switch).
4
-
86678
... More
23 SITC of free standing floor mounted dust and vermin proof compartmentalised outdoor cubical panels made out of CRCA sheet , required hardware ,duly treated for derusting in 7 tank process with dephosphating and with powder coating on both side of panels in desired shade The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness , separate detachable gland plate M.S. base channel ,hinged door with locking arrangement for equipment /switchgear . Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required . Side walls and cable alley compartments having bolted type doors with / without detachable extension type structure. TP&N aluminium busbar for minimum 300 Amps of suitable rating for connections and other required Accessories. All complete as per CPWD specifications and direction of Engineer-in-charge.(Panels shall be TTA approved)(Including voltmeter, ammeter, indication lamp, CT, setector switch) (These panels are meant to supply power to OD Units & ID Units of the VRV/VRF ACs.)
10
-
51322.5
... More
24 Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
24.1 630 A,50KA,TPMCCB
2
-
27860
... More
24.2 250A 25kA TP MCCB
9
-
12984
... More
24.3 125A 16kA TP MCCB
8
-
4821
... More
24.4 100 A, 16 KA,TPMCCB
8
-
3777
... More
25 Supplying and fixing following way, single pole and neutral , sheet steel MCB DISTRIBUTION BOARD 240 volts on surface/ recess complete with, tinned copper bus bar, neutral link, earth bar, din bar, interconnections, powder painted including earthing etc. as required.(But without MCB/ RCCB/ Isolator).
25.1 12 way double door
9
-
2315
... More
26 Supplying and fixing 5 amps to 32 amps, rating, 240/415 volts, 'C' Curve , miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
26.1 Single Pole
224
-
256
... More
26.2 Double pole
27
-
656
... More
27 Supplying and fixing folowing rating Triple pole 240 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required.
27.1 63 amp TPN MCB
9
-
1999.35
... More
28 Supplying and fixing following rating double pole (Single phase & neutral), 240volts, Residual current Circuit Breaker ( RCCB ) , having sensitivity of 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
28.1 63 amp DP RCCB
9
-
2722
... More
29 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
29.1 4 X 10 sq. mm (25mm)
6
-
269
... More
29.2 4 X 16 sq. mm (28mm)
12
-
309
... More
29.3 4 X 25 sq. mm (28mm)
6
-
315
... More
29.4 3½ X 95 sq. mm (45mm)
4
-
588
... More
29.5 3½ X 120 sq. mm (45mm)
4
-
613
... More
29.6 3½ X 400 sq. mm (82mm)
2
-
1556
... More
30 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
1344
-
51
... More
SH-03 (Earthing ) 31 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
2
-
7472
... More
32 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm).
30
-
144
... More
33 Comprehensive Annual maintenance of VRV/VRF Air conditioning system provided and installed under this contract with all parts/components i.e. compressor, gas charging, fan motor etc(one year free defect liability period and thereafter paid). a) For 1st Year (During defect liability period)
247
-
-
... More
b) For 2nd Year
247
-
2800
... More
c) For 3rd Year
247
-
2940
... More
d) For 4th Year
247
-
3087
... More
e) For 5th Year
247
-
3240
... More
f) For 6th Year
247
-
3402
Evaluation Notes How It Works ?