Netaji Subhas Institute Of Technology Tender

If you're typing tender ID over and again or finding it difficult to go through the cumbersome government websites for looking at Delhi tenders online. We have come up with a solution i.e. we have collated every eprocurement Delhi tender on BidAssist. Also, for any queries related to an e-tender Delhi, like the bidding process, registration process, etc., the same are explained below.

Netaji Subhas Institute Of Technology - NSIT Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date4 Jun 2018
Closing Date18 Jun 2018
Tender Amount₹ 49,29,430 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
4 Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured): a.) From brick work in cement mortar

6.77

-

2798.6

... More
B EARTH WORK 5 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All Kind of Soil

46.51

-

166.4

... More
6 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

98.22

-

125.75

... More
7 Supplying and stacking at site. a.) Good earth

65.1

-

332.55

... More
8 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : a.) Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration

403.46

-

131.9

... More
C CONCRETE WORK 9 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)

5.32

-

4478.15

... More
10 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.

13.04

-

91.9

... More
11 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.

52.26

-

450.35

... More
D REINFORCED CEMENT CONCRETE WORK 12 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :. a.) 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size).

12.76

-

6215.35

... More
13 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : a.) 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).

20.38

-

7145.8

... More
14 Centering and shuttering including strutting, propping etc. and removal of form for all heights : a.) Foundations, footings, bases of columns, etc. for mass concrete

44.83

-

193.95

... More
b.) Lintels, beams, plinth beams, girders, bressumers and cantilevers

53.49

-

342.9

... More
c.) Columns, Pillars, Piers, Abutments, Posts and Struts

116.67

-

467.85

... More
15 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. a.) Thermo-Mechanically Treated bars of grade Fe-500D or more.

597

-

56.6

... More
16 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. a.) Thermo-Mechanically Treated bars of grade Fe-500D or more.

796

-

56.6

... More
E BRICK WORKS 17 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)

6.56

-

4751.65

... More
18 Brick work with common burnt clay machine moulded F.P.S. (non modular) bricks of class designation 12.5 in exposed brick work including making horizontal and vertical grooves 10 mm wide 12 mm deep complete in cement mortar 1:6 (1 cement : 6 coarse sand). Above plinth level upto floor V level

39.35

-

5864.55

... More
19 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in : cement mortar 1:4 (1 cement : 4 coarse sand)

25

-

593.5

... More
20 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.

25

-

56.85

... More
F ALUMINUM WORKS 21 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : a.) Powder coated aluminium (minimum thickness of powder coating 50 micron)

174

-

384.5

... More
22 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) a.) Powder coated aluminium (minimum thickness of powder coating 50 micron)

255

-

444.9

... More
23 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-in-charge. a.) Pre-laminated particle board with decorative lamination on both sides

8.63

-

866.6

... More
24 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): a.) With float glass panes of 5.0 mm thickness

23.46

-

891.53

... More
25 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : a.) 300x10 mm

20

-

99.7

... More
b.) 150x10 mm

20

-

64.3

... More
26 Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodised coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete.

5

-

622.15

... More
G STEEL WORK & ROOFING 27 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

4937.6

-

58.45

... More
28 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin - charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

728

-

554.4

... More
29 Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete a.) Ridges plain (500 - 600mm)

142

-

360.45

... More
b.) Gutter .(600 mm over all girth)

56

-

833.05

... More
H FLOORING 30 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick

216.95

-

1158.1

... More
31 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.

20.45

-

1238.2

... More
I FINSIHING 32 12 mm cement plaster of mix : a.) 1:6 (1 cement: 6 fine sand)

255.13

-

160.35

... More
33 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

217.6

-

87.35

... More
34 Distempering with 1st quality acrylic distemper (ready mixed) of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. a.) Two or more coats on new work

217.6

-

53.15

... More
35 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade a.) Old work (one or more coats)

192.7

-

33.35

... More
36 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: a.) New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

415.28

-

96.8

... More
I FALSE CEILING 37 Providing and fixing tiled false ceiling at all height of approved materials of size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x25 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. A.) GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.

353.84

-

1163.9

... More
I PLUMBING WORKS 38 Providing and fixing soil, waste and vent pipes : A.) 100 mm dia. Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989

25

-

921.65

... More
B.) 75 mm diameter Centrifugally cast (spun) iron socketed pipe as per IS: 3989

15

-

794.55

... More
39 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. A.) 20 mm nominal outer dia Pipes

25

-

333.6

... More
B.) 25 mm nominal outer dia Pipes

15

-

398.65

... More
40 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. a.) 110 mm

14.4

-

181.4

... More
41 Providing and fixing Stainless Steel A ISi 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required. Kitchen sink without drain board 610x510 mm bowl depth 200 mm

2

-

2476.6

... More
42 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: a.) 150 x 100 mm size P type b.) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

2

-

1623.25

... More
43 Constructing brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : a.) Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : b.) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

2

-

8634.1

... More
Deduct - On account of Buy Back Steel Scrap & Old Bricks By The Contractor 44 Deduction of steel scrap (Ref Item No. 2 )

1150.8

-

15.5

... More
Deduct - 45 Deduction of Old Bricks (Ref Item No. 4a)

6767

-

2

... More
Schedule of Quantity for Electrical Work ( Part - “B”) WIRING AND ACCESSORIES 1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group A

70

-

702

... More
2 Wiring for group controlled (looped ) light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group A

66

-

415

... More
3 Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin , 15/16 Amps modular socket outlet and 15/16 Amps modular switch , connection etc . as required .

28

-

406

... More
4 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. ( FOR TELEPHONE, DATA OUTLET ) a) 1 OR 2 Module (75mmX75mm)

14

-

175

... More
5 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC copper conductor single core cable in surface/ recessed insulated steel conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. (for power points and for ETAC points)

800

-

239

... More
6 Wiring for circuit/ submain wiring alongwith earth wire following sizes of FRLS PVC insulated copper conductor, single with the core cable in surface/ recessed steel conduit as required a) 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire

80

-

181

... More
b) 2 x 4 sq. mm + 1 x 4 sq. mm earth wire

80

-

237

... More
c) 2 x 10 sq. mm + 1 x 6 sq. mm earth wire

140

-

392

... More
d) 4 x 10 sq. mm + 2 x 6 sq. mm earth wire

30

-

536

... More
7 Supplying and fixing modular blanking plate ,on the existing modular plate & switch box excluding modular plate etc. as required.

50

-

24

... More
MV / LV CABLING & ITS TERMINATIONS & CABLE TRAYS 1 Supply of following sizes of XLPE insulated PVC sheated, Al conductor armoured power Cable of 1.1 KV grade etc as reqd. ( FOR Main board ) a) 3.5 x 150 Sqmm

200

-

499.52

... More
2 Supplying and making indoor end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed/XLPE copper conducter cable of 1.1 kV grade as required i/c supplying and fixing of bimettalic crimping lugs, double compression glands with earthing. a) 3.5 x 150 Sqmm (50 mm)

2

-

580

... More
3 Laying and fixing of one number XLPE insulated and PVC sheathed power cable of 1.1 KV grade of following size direct in ground including sand cushioning, protective covering and refilling the trench etc as required a) more than 95 sqmm and up to 185 sq.mm

180

-

223

... More
4 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required. a) more than 95 sqmm and up to 185 sq.mm

10

-

37

... More
5 Laying and fixing of one number PVC insulated and PVC sheathed /XLPE power able of 1.1 KV grade of following Sze on wall surface as required (a) Above 95 sqmm and upto 185 sqmm (clamp with 25/40 x 3mm msflat clamp)

10

-

84

... More
SH-02, MV / LV CABLING & ITS TERMINATIONS, CABLE TRAYS. 1 Suppy, Installation, Testing and Commissioning of MV cubical type Panel suitable for 415 Volt, 3phase, 4wire 50Hz AC supply system fabricated in compartmentalized from CRCA sheet steel not less than 2mm thick duly treated with 7 tanks process, powder coated with minimum 60micron thickness of approved shade and oven dried. It will have a suitable MS base channel powder coated. The Panel will be fabricated in transportable sections. The panel shall have a common Aluminium earth bar of size 50mm x 6mm at the rear with 2 Nos. earth studs. The LT panel will have suitable arrangement for bus-ducting/ cable termination into various incoming/ outgoing switchgear as required. Cable termination will be at suitable terminal block at top/bottom of the panel and from the teminal block to switch, connection will be made with solid insulated strip/PVC insulated copper conductor cable of required current rating as required. current density in bus bar not to exceed 130 amp/sqcm. The panel shall be complete with following switchgear and accessories i/labelling (A) INCOMER 200 A TP MCCB, 25 ka, Ics=Icu ,with handle and spreader thermal magnetic release (B) BBC and metering 4 strip 250 A Aluminium Bus bar Digital Multifunction meter to indicate V, I, pf, KW,KWH having port for remote data transfer ( C ) Outgoings 63 A TPN MCCB , 25 Ka, Ics=Icu: 3 nos 63 A DP MCB : 9 nos ( 3 in each compartment ) (D) Spare Blank compartment for future use: 2 NOS

1

-

86180

... More
2 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel MCB DISTRIBUTION BOARD 415 volts on surface/ recess complete with, tinned copper bus bar, neutral link, earth bar, din bar, interconnections, powder painted including earthing etc. as required.(But without MCB/ RCCB/ Isolator) a 4 way (4+ 12 ) ,Double Door

1

-

2198

... More
3 Supplying and fixing following way,single pole and neutral , sheet steel MCB DISTRIBUTION BOARD 240 volts on surface/ recess complete with, tinned copper bus bar, neutral link, earth bar, din bar, interconnections, powder painted including earthing etc. as required.(But without MCB/ RCCB/ Isolator) a) 12 way double door

9

-

1151

... More
4 Supplying and fixing 5 amps to 32 amps, rating, 240/415 volts, 'C' Curve , miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) Single Pole

80

-

173

... More
5 Supplying and fixing following rating double pole 240volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 20 amp. DP MCB (C- Curve)

3

-

463

... More
b) 63 amp DP MCB (C- Curve)

6

-

463

... More
6 Supplying and fixing following rating double pole 240volts, Residual current Circuit Breaker ( RCCB ) , having sensitivity of 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 25 amp.DP RCCB

3

-

1650

... More
b) 63 amp DP RCCB

6

-

2242

... More
7 Supplying and fixing following rating four pole 415volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 40 amp. TPN MCB (C- Curve)

1

-

891

... More
8 Supplying and fixing DP sheet steel Distribution board on surface or in recess alongwith 16 A DP MCB C-Curve, complete with connections, testing and commissioning etc. as required. ( for ET AC equipments )

8

-

627

... More
SH-03 (MAIN LT PANEL & DISTRIBUTION BOARD) LIGHT FIXTURES 1 Providing and fixing recess approx 600mm x 600 mm LED luminaire of 36 watt , Direct/ side Indirect Lighting system ,complete in all respects including making connections ,testing commissioning etc as required. Luminaire shall be Pre-wired quick connect system Colour temperature 4500-5000, CRI ≥80 and quarter binning minimum Macadam 3 rating. Driver type should be of constant current with input voltage 220-240 V, power factor 0.9 and efficiency of ≥ 85 %, THD ≤ 10%, Surge protection (L-N) 1KV, Surge protection (E-L/N) 2 KV. Having open load and short circuit protection confirming to EN 61547. The system efficacy of Luminaire shall be minimum 110 lm/W , LM70 tested, working temp -10 to +45 deg. C, IP rating 20 , with guaranteed system life of 50000 burning Hrs or 7 years whichever is earlier. The luminaire should be confirming to BIS IS10322 (part V/Section I) The diffuser shall be extruded acrylic lens of 1.6 to 2 mm thick, satin finish co-extruded with integrated reflector finished in high reflectance and conforming to safety-glow-wire-test pass at 8500 C as required. Diffuser to be integrated in a snap fit arrangement to the extruded aluminium housing Installation: Luminaire to be suspended from the true ceiling using Anchor fastner of minmum 8 m dia and OEM supplied Hanger Wire kit comprising of flexible hanger wire, cable adjuster and suspension clip, so that complete load of fitting is transferred to true ceiling.

74

-

5817

... More
2 S/I/T/C LED surface/recess type downlighter 9 watt round in shape having good quality diffuser, system efficacy minmum 110 lumen/watt , color temp 4000-5000 deg K,

35

-

1596.89

... More
3 Supply ,Installation testing and commissioning of BEE 5 star ,ceiling fan 1400mm sweep complete with standard down rod and other accessories etc. as required.

19

-

2249

... More
4 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate as required & switch box 1/c connection but excluding modular plate etc. as required.

19

-

288

... More
DATA SYSTEM CABLING AND CONDUITING 1 Supplying and fixing modular switch/ socket outlet,on the existing modular plate & switch box including connections but excluding modular plate etc. as required. a) Telephone/ Data Socket Outlet/ TV outlet

7

-

96

... More
2 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor unarmoured telephone cable in the existing surface/recess steel/pvc conduit as required a) 2 Pair

100

-

19

... More
b) 4 Pair

50

-

28

... More
3 Supply and laying of 4 Pair UTP Cable 23 AWG copper with integral cross-member pair separator (bidirectional tape, strips and others will not be accepted) for uniform characteristic impedence should meet or exceed the TIA/EIA 568-B. 2-1 (Cat-6) standards for physical and electrical specifications. (Tested to 600 MHz. a) Cat-6 Cable

50

-

33

... More
4 Supplying and fixing of following sizes of medium class steel conduits along with accessories in surface/ recess including painting in case of surface conduit,or cutting the wall and making good the same in case of recessed conduit as required. a) 25mm SH-05, TELEPHONE/DATA SYSTEM CONDUITING AND CABLING

200

-

147

... More
SH 06 ETAC PLANT 1 Supply ,Installation at site as required ,testing and commissioning of Package Evaporatice Cooling unit ( similar to Symphony PAC 6 TC ) ,complete in all respects , having Cooling capacity - 72000 BTU/hr ( 6 tons of air cooling) fan cfm : 8000 cfm Suitable for cooling up to 300 cum space Minimum 40 liter tank capacity High efficiency honeycomb cooling pads Double canvass flexible connection from existing duct Made of automotive steel , long lasting epoxy powder coated

8

-

70000

... More
2 Supply, Installing, Testing and Commissioning of 1400 rpm single phase Heavy Duty Exhaust fans Complete with Bird Screen & Gravity Shutter complete as requrid a) 450 mm Dia ,

8

-

6501

... More
3 Supplying , installation,balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with meoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. As per approved drawing specifications of following sheet thickness complete as required. a) 0.80 mm (Thickness 0.80mm sheet)

125

-

751

... More
b) 0.63 mm (Thickness 0.60mm sheet)

25

-

630

... More
4 Supply, Installation, Testing and Commissioning of GI Volume Control Dampers complete with neoprene rubber gaskets,nuts, bolts, screw linkages, flanges etc. as per specifications.

4

-

5463

... More
5 Supplying and fixing of acoutic linning of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m3 with 25 x 25 mm GI section of 1.25 mm thick at 600 mm c-to-c covered with hreinforced plastic tissue paper and 0.5 mm perforated Aluminium sheet fixed to inside surface of duct with cadmium plated nuts,bolt,stick pins , cold setting adhesive (CPRX compound ) etc complete as required and as per specification .

50

-

551

... More
6 Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (class "O") insulation on existing duct after applying two coated of cold setting adhesive (CPRX compound ). The joints shall sealed with 50mm wide thick self adhesive nitrile rubber tape insulation complete as per specification and as required. a) 19 mm

100

-

821

... More
7 Supply & fixing of 25 mm dia PVC flexible/PPR supply/drain pipe heavy duty ISI marked 3 mm thick outer dia with clamps on surface/ recessed etc. and as requried.

60

-

300

... More
8 Supplying and fixing of powder coated extruded aluminum supply air grills with aluminum volume control dampers as per specification . SUB TOTAL FOR SH-06, ETAC

12

-

7132

... More
Earthing 1 Earthing with G.I earth plate 600mm x 600mm x 6mm including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe 2.7 mtr long etc with charcoal,coke and salt as required.

2

-

4327

... More
2 Providing and fixing 25mmx5mm GI strip in 40 mm dia GI pipe from earth electrode including connectionwith G.I nut bolt spring washer excavation and refilling etc. complete as required

30

-

351



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.